Floating Circuits - Protection against electric shock

Size: px
Start display at page:

Download "Floating Circuits - Protection against electric shock"

Transcription

1 Floating Circuits - Protection against electric shock Introduction TECHNICALLY SPEAKING by Richard Nute 1998 Richard Nute FLOATING CIRCUITS PROTECTION AGAINST ELECTRIC SHOCK Probably the least-understood issue in product safety is that of protection against electric shock from a floating or isolated circuit A floating or isolated circuit is a one that has no connection to any other circuit or to ground For the purpose of this paper, we assume that the pole-to-pole voltage of the floating circuit is hazardous voltage Such circuits are commonly used as high voltage supply circuits for the screen backlight for laptop computers Figure 1 depicts a floating or isolated circuit The energy source is grounded For the purposes of this discussion, the secondary circuit (pole-to-opposite pole) is Hazardous Voltage (as defined in IEC 950, Subclause 1283) and hazardous current (exceeds the limits for Limited Current as defined in IEC 950, Sub-clauses 1286 and 242) The secondary circuit is isolated from all other circuits by the transformer functional insulation, and the other functional insulations However, there is a very small leakage current in the stray impedances of the functional insulations Typically, this current would be in the microampere range, but may be higher if the circuit frequency is in the kilohertz range One characteristic of a floating or isolated circuit is that the circuit, from either pole to ground (or from either pole to any other conductive part), under normal conditions, is a Limited Current circuit as defined in IEC 950, Sub-clauses 1286 and 242 Another characteristic of the floating or isolated circuit is that it has TWO simultaneous shock current paths, one being pole-to-opposite pole, and the other being pole-to-ground-to-opposite pole Figures 2A and 2B show the shock current path for the two situations (For the purposes of this paper, each shock current path is discussed separately) M:/ /Floating Circuits - Protection ag 1/6

2 Pole-to-opposite pole Figure 2A depicts the circuit path when a man simultaneously touches both poles of the floating or isolated circuit In this situation, there is no insulation The current is limited only by the impedance of the body of the circuit and the man, then we prevent shock current through the body See Figure 3 If we interpose Basic Insulation between one pole Notice that the opposite pole is still accessible But, the Basic Insulation prevents shock current through the body,,, We must also consider the failure of Basic Insulation In the case of failure of the Basic Insulation, shock current would pass through the body as if there was no M:/ /Floating Circuits - Protection ag 2/6

3 insulation We have several options to prevent electric shock current We could interpose a second insulation on top of the Basic Insulation, thus making a Double Insulation system Or, we could interpose a grounded metal part on top of the Basic Insulation to create an equipotential environment Note that one pole of the floating circuit must have Double or Reinforced Insulation between it and ground, while the other pole need have only functional/operational insulation (This follows because we originally depicted the man as touching one pole of the circuit as if it was a NORMAL condition) (Note also that failure of the functional/operational insulation actually shunts the current AWAY from the man!) Normally, however, the man would not have access to either pole of the floating circuit We can prevent pole-to-opposite pole current by preventing simultaneous access to BOTH poles of the floating circuit If we interpose an insulating barrier between one pole of the floating circuit and the man, then we can define that barrier as Basic Insulation In the event of failure of that Basic Insulation, there is no electric shock current in the man Insulation (because it provides insulation against the SECOND body connection) If we extend that same insulation such that it is interposed between the OPPOSITE pole and the man, then we can define the OPPOSITE pole portion of the insulation as Supplementary Voila! With a single layer of insulation, we have created an elegant and least-cost Double Insulation scheme The same insulation one part -- plays both the role of Basic Insulation and Supplementary Insulation! See Figure 4 Pole-to-ground-to-opposite pole Figure 2B depicts the circuit path when a man simultaneously touches one pole of the floating or isolated circuit and ground In this circuit, functional/operational insulation is interposed between ground and the opposite pole of the isolated/floating circuit The current is limited by the impedance of the functional/operational insulation This being the case, then the functional/operational insulation must be Basic Insulation See Figure 5 Let s now examine the situation for the M:/ /Floating Circuits - Protection ag 3/6

4 event of failure of the Basic Insulation If we short-circuit the Basic Insulation, we then have no current limit, and an electric shock current passes through the man We have several options to prevent electric shock current We could interpose a second insulation adjacent to the Basic Insulation, thus making a Double Insulation system Or, we could interpose a grounded metal part between the Basic Insulation and ground to create an equipotential environment (Note that failure of the functional/operational insulation actually shunts the current AWAY from the man!) This presents the same interesting construction as for the pole-to-opposite pole case One pole of the floating circuit must have Double or Reinforced Insulation between it and ground, while the other pole need have only functional/operational insulation (This follows because we have depicted the man as touching one pole of the circuit as if it was a NORMAL condition) Normally, however, the man would not have access to either pole of the floating circuit Assume that neither pole is accessible In the event of failure of the pole-to-ground Basic Insulation, we can prevent shock current by preventing access to either pole of the floating circuit Since we have defined the pole-to-ground insulation as Basic Insulation, we can define the pole-to-man insulation (barrier) as Supplementary Insulation The most elegant and least-cost solution is to interpose Supplementary Insulation between the circuit and the man See Figure 6 Insulation for protection against electric shock If we combine the results of our two situations, pole-toopposite pole and pole-to-ground-toopposite pole, we find that interposing Basic Insulation both between the floating/isolated circuit and accessible conductive parts and between the floating/isolated circuit and ground provides both Basic and Supplementary insulation in a single insulation See Figure 7 A conductive barrier for protection against electric shock M:/ /Floating Circuits - Protection ag 4/6

5 If we replace the insulating barrier with a conductive barrier, the insulation requirements change See Figure 8 There is no current path to the man There is no current path to ground There is no leakage current There is no Basic Insulation There is no Supplementary Insulation In this configuration, there is no current path for electric shock even though the conductive barrier is floating! This is an important concept Other secondary circuits may play the role of the conductive barrier If those circuits adjacent to the floating circuit are relatively low impedance, then functional/operational insulation is sufficient, and there is no need for Basic or Supplementary insulation between the floating circuit and other secondary circuits! M:/ /Floating Circuits - Protection ag 5/6

6 Conclusion We have shown two simple, cost-effective schemes for protection against electric shock from a floating or isolated circuit: 1 Preventing access to all parts of the circuit by means of a barrier of Basic Insulation, either air insulation or solid insulation, and Basic air or solid insulation between all parts of the circuit and ground 2 Preventing access to all parts of the circuit by means of a conductive barrier, where the insulation between the floating/isolated circuit and the barrier is functional/operational insulation The conductive barrier need not be grounded Other schemes are possible, but these are probably the least-cost schemes Back to The Product Safety Newsletter If you would like to contact the IEEE Webmaster, to webmaster@ieeeorg Copyright 2001, IEEE Terms & Conditions Privacy & Security (DanRoman@ieeeorg) URL: (Modified:07/29/2003 ) M:/ /Floating Circuits - Protection ag 6/6

Electrical Safety. Principles and examples of safety. History of (electrical) safety. Rules and regulations. Safety in the Hospital

Electrical Safety. Principles and examples of safety. History of (electrical) safety. Rules and regulations. Safety in the Hospital Electrical Safety History of (electrical) safety Safety in the Hospital Role of Clinical Engineer Rules and regulations Food and Drug Administration (FDA), Underwriter s Laboratory (UL), Federal Communication

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60728-11 1997 AMENDMENT 1 2000-10 Amendment 1 Cabled distribution systems for television and sound signals Part 11: Safety Amendement 1 Systèmes de distribution par câbles destinés

More information

25kV A.C. Electrified Lines - Traction Bonding

25kV A.C. Electrified Lines - Traction Bonding Date:MAR 94 25kV A.C. Electrified Lines - Traction Page 1 of 6 Part A Synopsis This is issued by the to define the Boards requirements for continuity bonding on railway systems. This will ensure a continuous

More information

Frequently Asked Question on Isolated Power Supply(IPS)

Frequently Asked Question on Isolated Power Supply(IPS) Frequently Asked Question on Isolated Power Supply(IPS) Q: What is an IPS? A: IPS is called as Isolated Power Supply or System and is used in a Hospital to ensure safe power supply to OT Operation Theaters

More information

Prepared by Mick Maytum

Prepared by Mick Maytum IEC Technical Committee 109: Standards on insulation co-ordination for low-voltage equipment Warning Prepared by Mick Maytum mjmaytum@gmail.com The document content is of a general nature only and is not

More information

ELECTRICAL SAFETY TESTERS. Wings for Your Projects. APPLICATION NOTE

ELECTRICAL SAFETY TESTERS. Wings for Your Projects. APPLICATION NOTE APPLICATION NOTE ELECTRICAL SAFETY TESTERS Wings for Your Projects. Four Principal Tests for Evaluating the Safety of Electrical and Electronic Products TOS SERIES ELECTRICAL SAFETY TESTER TOS SERIES SELECTION

More information

P3065 LOW PROFILE LINE MATCHING TRANSFORMER PRODUCT DATA SHEET. IEC 950, UL 1950 and EN certified UL Recognized Component

P3065 LOW PROFILE LINE MATCHING TRANSFORMER PRODUCT DATA SHEET. IEC 950, UL 1950 and EN certified UL Recognized Component PRODUCT DATA SHEET LOW PROFILE MATCHING TRANSFORMER P3065 Features Low Distortion Low Profile (11mm) Vacuum encapsulated IEC 950, UL 1950 and EN 60950 certified UL Recognized Component BABT Certificate

More information

P5059 LOW DISTORTION LINE MATCHING TRANSFORMER PRODUCT DATA SHEET

P5059 LOW DISTORTION LINE MATCHING TRANSFORMER PRODUCT DATA SHEET PRODUCT DATA SHEET LOW DISTORTION MATCHING TRANSFORMER P5059 Features Leadfree (Pbfree) RoHS compliant Low Distortion 11.2mm (0.44 ) Seated Height Industry Standard Pinout IEC 60950 and UL 60950 Certified

More information

P3065 LOW PROFILE LINE MATCHING TRANSFORMER PRODUCT DATA SHEET

P3065 LOW PROFILE LINE MATCHING TRANSFORMER PRODUCT DATA SHEET PRODUCT DATA SHEET LOW PROFILE MATCHING TRANSFORMER P3065 Features Low Distortion Leadfree (Pbfree) RoHS compliant Low Profile (11mm) Vacuum encapsulated IEC 60950 and UL 60950 certified UL Recognized

More information

MINING EARTH LEAKAGE PROTECTION WITH VARIABLE SPEED DRIVES

MINING EARTH LEAKAGE PROTECTION WITH VARIABLE SPEED DRIVES MINING EARTH LEAKAGE PROTECTION WITH VARIABLE SPEED DRIVES White Paper Tim Wylie, Ampcontrol s Chief Technology Officer discusses the impact of Variable Speed Drives (VSDs) on earth fault limited networks.

More information

P3304 LOW INSERTION LOSS LINE MATCHING TRANSFORMER PRODUCT DATA SHEET

P3304 LOW INSERTION LOSS LINE MATCHING TRANSFORMER PRODUCT DATA SHEET PRODUCT DATA SHEET LOW INSERTION LOSS LINE MATCHING TRANSFORMER P3304 Features Leadfree (Pbfree) RoHS compliant Low Insertion Loss,

More information

P3801 LOW DISTORTION LINE MATCHING TRANSFORMER PRODUCT DATA SHEET. V.90 and V.92 modems V.34 modems

P3801 LOW DISTORTION LINE MATCHING TRANSFORMER PRODUCT DATA SHEET. V.90 and V.92 modems V.34 modems PRODUCT DATA SHEET LOW DISTORTION MATCHING TRANSFORMER P3801 Features Leadfree (Pbfree) RoHS compliant Low distortion Environmentally tested to IEC 68 CERT reliability tested 12.6mm (0.5") seated height

More information

Industrial and Commercial Power Systems Topic 7 EARTHING

Industrial and Commercial Power Systems Topic 7 EARTHING The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 7 EARTHING 1 INTRODUCTION Advantages of earthing (grounding): Limitation

More information

P2001 LINE MATCHING TRANSFORMER PRODUCT DATA SHEET. 12.6mm (0.5") seated height

P2001 LINE MATCHING TRANSFORMER PRODUCT DATA SHEET. 12.6mm (0.5) seated height PRODUCT DATA SHEET MATCHING TRANSFORMER P2001 Features Ultra Low Distortion 12.6mm (0.5") seated height Vacuum encapsulated IEC 950, UL 1950 and EN 60950 Certified UL Recognized Component BABT Certificate

More information

Position Paper on IEEE Task Force on Insulator Icing Test Methods. Item # 5 Power Supply Requirements By Rudi F. Kremer Vice President

Position Paper on IEEE Task Force on Insulator Icing Test Methods. Item # 5 Power Supply Requirements By Rudi F. Kremer Vice President Position Paper on IEEE Task Force on Insulator Icing Test Methods Item # 5 Power Supply Requirements By Rudi F. Kremer Vice President 1 1. Abstract 2 AC single phase power supplies utilized for alternating

More information

P2001 LINE MATCHING TRANSFORMER PRODUCT DATA SHEET

P2001 LINE MATCHING TRANSFORMER PRODUCT DATA SHEET PRODUCT DATA SHEET MATCHING TRANSFORMER P2001 Features Ultra Low Distortion Leadfree (Pbfree) RoHS compliant 12.6mm (0.5") seated height Vacuum encapsulated IEC 60950 and UL 60950 Certified UL Recognized

More information

6. Internal lightning protection

6. Internal lightning protection 6. Internal lightning protection 6.1 Equipotential bonding for metal installations Equipotential bonding according to IEC 60364-4- 41 and IEC 60364-5-54 Equipotential bonding is required for all newly

More information

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide

Agilent U1273A/U1273AX Handheld Digital Multimeter. Quick Start Guide Agilent U1273A/U1273AX Handheld Digital Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads One pair of 4

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: 285573 Date of issue...: 2015-09-15

More information

White Paper: The Importance of Isolation

White Paper: The Importance of Isolation Acromag, Incorporated 30765 S Wixom Rd, Wixom, MI 48393 USA Tel: 248-295-0880 Fax: 248-624-9234 www.acromag.com White Paper: The Importance of Isolation Learn How to Recognize the Need for Isolation Examining

More information

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models Solid-state Power OFF-delay Timer H3DE-H Timers Two delay-time models available. 0.1 to 12 seconds (S Series) 1 to 120 seconds (L Series) Covers wide range of supply voltage. Model Number Structure Model

More information

1. general. 1.1 electric shock. 1.2 direct and indirect contact. electric shock. indirect contact. direct contact

1. general. 1.1 electric shock. 1.2 direct and indirect contact. electric shock. indirect contact. direct contact 1. general 1.1 electric shock when a current exceeding 30 ma passes through a part of a human body, the person concerned is in serious danger if the current is not interrupted in a very short time. the

More information

Subject: Proposal to replace the TBDs for Fast 160 in SPI-4 and to winnow the options

Subject: Proposal to replace the TBDs for Fast 160 in SPI-4 and to winnow the options T10/00-389r0 Seagate Technology 10323 West Reno (West Dock) Oklahoma City, OK 73127-9705 P.O. Box 12313 Oklahoma City, OK 73157-2313 Tel: 405-324-3070 Fax: 405-324-3794 gene_milligan@notes.seagate.com

More information

Chapter F Protection against electric shocks

Chapter F Protection against electric shocks Chapter F Protection against electric shocks 1 2 3 4 5 6 7 8 Contents General 1.1 Electric shock F2 1.2 Protection against electric shock F3 1.3 Direct and indirect contact F3 Protection against direct

More information

Chapter F Protection against electric shocks

Chapter F Protection against electric shocks Chapter F Protection against electric shocks 1 2 3 4 5 6 7 8 Contents General 1.1 Electric shock F2 1.2 Protection against electric shock F3 1.3 Direct and indirect contact F3 Protection against direct

More information

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER GROUNDED ELECTRICAL POWER DISTRIBUTION Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER .0 Conductors for Electrical Power Distribution For single-phase transmission of AC power or

More information

INTERPLANT STANDARD - STEEL INDUSTRY

INTERPLANT STANDARD - STEEL INDUSTRY INTERPLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR MOULDED - CASE CIRCUIT-BREAKER FOR VOLTAGES NOT EXCEEDING 1000 V ac OR 1500 V dc (FIRST REVISION) IPSS:1-04-004-11 IPSS BASED ON IS/IEC 60947(Part

More information

05e28 Di-electric Strength (High Voltage) Test and Leakage Current Test Proficiency Testing Program

05e28 Di-electric Strength (High Voltage) Test and Leakage Current Test Proficiency Testing Program instructions Di-electric Strength (High Voltage) Test and Leakage Current Test Proficiency Testing Program Please read the instructions carefully and perform the testing as directed. Should you have any

More information

Grounding for Power Quality

Grounding for Power Quality Presents Grounding for Power Quality Grounding for Power Quality NEC 250.53 states that ground resistance should be less than 25 ohms. Is this true? Grounding for Power Quality No! NEC 250.53 states

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2009-04-10 Page 3 of 58 Report Reference # E116994-A48-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL 60601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference

More information

Product Classroom. Introduction. Grounding Systems. TN system. Title. Grounding System Introduction. Date October, 2016.

Product Classroom. Introduction. Grounding Systems. TN system. Title. Grounding System Introduction. Date October, 2016. Title Grounding System Introduction Date October, 2016 Related Products Key words All industrial automation products Grounding, Earthing, TN, TT, IT, Introduction The automation industry of today has adopted

More information

IEEE WORKING GROUP ON VOLTAGES AT PUBLICLY AND PRIVATELY ACCESSIBLE LOCATIONS. Web Cast May 17, 2007

IEEE WORKING GROUP ON VOLTAGES AT PUBLICLY AND PRIVATELY ACCESSIBLE LOCATIONS. Web Cast May 17, 2007 IEEE WORKING GROUP ON VOLTAGES AT PUBLICLY AND PRIVATELY ACCESSIBLE LOCATIONS Web Cast May 17, 2007 CHAIR CHUCK DENARDO (414) 221-3073 (chuck.denardo@we-energies.com) VICE CHAIR JIM BOUFORD (508) 421-7648

More information

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01 SEC DISTRIBUTION GROUNDING STANDARD SDCS-03 Part-II Rev.01 SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING Rev. 01 This specification is property of SEC

More information

User's Guide. AC Circuit Load Tester. Model CT70

User's Guide. AC Circuit Load Tester. Model CT70 User's Guide AC Circuit Load Tester Model CT70 Introduction Congratulations on your purchase of the CT70 AC Circuit Load Tester. This device can detect circuit and wiring problems such as: Poor ground

More information

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E. Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E. HP Critical Facility Services delivered by EYP MCF What is VOLTAGE? Difference of Electric Potential

More information

Back to the Basics Current Transformer (CT) Testing

Back to the Basics Current Transformer (CT) Testing Back to the Basics Current Transformer (CT) Testing As test equipment becomes more sophisticated with better features and accuracy, we risk turning our field personnel into test set operators instead of

More information

3.7 Grounding Design for EAST Superconducting Tokamak

3.7 Grounding Design for EAST Superconducting Tokamak 3.7 Design for EAST Superconducting Tokamak LIU Zhengzhi 3.7.1 Introduction system is a relevant part of the layout of Tokamak. It is important and indispensable for the system reliability and safety on

More information

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS AMENDMENT NO. 1 SEPTEMBER 2011 TO IS 15086 (Part 1) : 2001/IEC 60099-1 (1991) SURGE ARRESTORS PART 1 NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTORS FOR a.c. SYSTEMS (The Amendment was originally published

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2007-10-24 Page 1 of 6 Report Reference # E210157-A29-UL-1 SPECIFIC TECHNICAL CRITERIA UL 60950-1, First Edition Information technology equipment - Safety- Part 1: General Requirements Report

More information

Design Considerations

Design Considerations Design Considerations APPLICATION NOTES: Multi-hole cores provide specialized shapes that are sometimes more useful than single hole devices. One example is wide band transformers where good coupling between

More information

(12) Patent Application Publication (10) Pub. No.: US 2001/ A1

(12) Patent Application Publication (10) Pub. No.: US 2001/ A1 US 2001 004.8356A1 (19) United States (12) Patent Application Publication (10) Pub. No.: US 2001/0048356A1 Owen (43) Pub. Date: Dec. 6, 2001 (54) METHOD AND APPARATUS FOR Related U.S. Application Data

More information

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web:  - Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996

More information

IEC ED.1 Safety secondary circuits in series circuits General safety requirements. a new draft

IEC ED.1 Safety secondary circuits in series circuits General safety requirements. a new draft Helmut Schmidt Project leader of IEC /TC97 project team 62870 IEC 62870 ED.1 Safety secondary circuits in series circuits General safety requirements a new draft Schmidt Personal Safety IES ALC Conference

More information

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide

Agilent U1251B and U1252B Handheld Digital Multimeter. Quick Start Guide Agilent U1251B and U1252B Handheld Digital Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide

More information

Los A LA-UR Los Alamos National Laboratory Los Alamos, New Mexico 87545

Los A LA-UR Los Alamos National Laboratory Los Alamos, New Mexico 87545 LA-UR-98-1 Los Alamos NationalLaboratory is operated by the University of California for the United States Department of Energy under contract W-7405-ENG-36 TITLE: SUBMITTED TO: Electrical Potential Transfer

More information

Options to Improve the MEN System into the 21 st Century

Options to Improve the MEN System into the 21 st Century Options to Improve the MEN System into the 21 st Century Chris Halliday Electrical Consulting and Training Pty Ltd, Gladstone NSW, Australia. Email: chris@elect.com.au Web: www.elect.com.au Abstract Network

More information

Lecture (03) Diodes and Diode Applications I

Lecture (03) Diodes and Diode Applications I Lecture (03) Diodes and Diode Applications I By: Dr. Ahmed ElShafee ١ Agenda VOLTAGE CURRENT CHARACTERISTIC OF A DIODE Forward bias Reverse Bias V I Characteristic for Forward Bias V I Characteristic for

More information

Lecture (03) Diode applications

Lecture (03) Diode applications Lecture (03) Diode applications By: Dr. Ahmed ElShafee ١ Agenda The Basic DC Power Supply Half wave rectifier Full wave rectifier Filters Voltage Regulators ٢ The Basic DC Power Supply All active electronic

More information

Keysight U1241C/ U1242C Handheld Digital Multimeter. Quick Start Guide

Keysight U1241C/ U1242C Handheld Digital Multimeter. Quick Start Guide Keysight U4C/ U4C Handheld Digital Multimeter Quick Start Guide Safety Notices CUTION CUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly

More information

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN):

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN): Single Earthed Neutral and Multi Earthed Neutral. SEPTEMBER 6, 2011 5 COMMENTS Single Earthed Neutral and Multi Earthed Neutral: In Distribution System Three Phase load is unbalance and non linear so The

More information

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

TA MHz x10/x100 Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2. TA043 100 MHz x10/x100 Differential Probe User s Manual This probe complies with IEC-1010.1, IEC-1010.2 031 CAT III, Pollution Degree 2. 1. Safety terms and symbols Terms appearing in this manual: WARNING

More information

Biomedical. Measurement and Design ELEC4623/ELEC9734. Electrical Safety and Performance Standards

Biomedical. Measurement and Design ELEC4623/ELEC9734. Electrical Safety and Performance Standards Biomedical Instrumentation, Measurement and Design ELEC4623/ELEC9734 Electrical Safety and Performance Standards Contents Physiological Effects of Electrical Currents Safety Standards for Medical Instrumentation

More information

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit Current will always try to return to its source In order for there to be current, there must be a complete circuit Current will take as many paths or circuits available to it to return to the source The

More information

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56 1. Two Electrical Technicians are discussing markings that are required for AC wiring. Tech A says that AC conductors must be rated for 600 volts and must have their jackets and individual conductors marked

More information

Effective switching mode power supplies common mode noise cancellation technique with zero equipotential transformer models. Title

Effective switching mode power supplies common mode noise cancellation technique with zero equipotential transformer models. Title Title Effective switching mode power supplies common mode noise cancellation technique with zero equipotential transformer models Author(s) han, YP; Pong, MH; Poon, NK; Liu, P itation The 25th Annual IEEE

More information

Minutes of the IEEE PSES TSTC teleconference held Wednesday, June 25, 2014 at 11:00 AM EST, for one hour.

Minutes of the IEEE PSES TSTC teleconference held Wednesday, June 25, 2014 at 11:00 AM EST, for one hour. Minutes of the IEEE PSES TSTC teleconference held Wednesday, June 25, 2014 at 11:00 AM EST, for one hour. 1. Attendance/Introductions Members present: Don Gies (Alcatel-Lucent), Al Martin (retired), Mick

More information

Tech Talk (12) Down to Earth: A Discussion of the General Requirements for the Earthing of Control and Instrumentation Systems

Tech Talk (12) Down to Earth: A Discussion of the General Requirements for the Earthing of Control and Instrumentation Systems 701880MAC0010.1177/0020294017701880 research-article2017 Contributed Paper Tech Talk (12) Down to Earth: A Discussion of the General Requirements for the Earthing of Control and Instrumentation Systems

More information

NOTE: This paper relates to a closed book exam & therefore candidates should attempt this exam paper with no study-notes or text books.

NOTE: This paper relates to a closed book exam & therefore candidates should attempt this exam paper with no study-notes or text books. City & Guilds Fundamental Inspection & Testing 30 Question Test Sheet (2392-10 Paper No1.) NOTE: This paper relates to a closed book exam & therefore candidates should attempt this exam paper with no study-notes

More information

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017 Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175, ART-B22-D300 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and

More information

Understanding Noise Cut Transformers

Understanding Noise Cut Transformers 2014 Understanding Noise Cut Transformers By Quality Transformer and Electronics James Nealon Understanding Noise Cut Transformers By Quality Transformer and Electronics Engineering and Sales Staff Quality

More information

Agilent U1211A, U1212A, and U1213A Clamp Meter. Quick Start Guide U1211A U1212A U1213A

Agilent U1211A, U1212A, and U1213A Clamp Meter. Quick Start Guide U1211A U1212A U1213A Agilent U1211A, U1212A, and U1213A Clamp Meter U1211A U1212A U1213A The following items are included with your clamp meter: Standard test leads with 19 mm probes Soft carrying case and 4 mm probes Certificate

More information

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web: -

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web:  - MZB SERIES Intrinsically Safe Shunt Diode Safety Barriers Turck of Intrinsically Safe Shunt Diode Safety Barriers New series of Zener Barriers include a wider product range for more flexibility in more

More information

Residual Current Operated Circuit-Breakers (RCCBs)

Residual Current Operated Circuit-Breakers (RCCBs) Product Overview Residual Current Operated Circuit-Breakers (RCCBs) Residual current operated circuit-breakers Number of poles Rated current A Rated residual current ma MW Auxiliary contacts can be mounted

More information

NL800A - Stimulus Isolator

NL800A - Stimulus Isolator NL800A - Stimulus Isolator Introduction The NL800A STIMULUS ISOLATOR is a battery powered, opto-coupled isolator. It has a constant current output, with very high output impedance, making it suitable for

More information

APPLICATION OF A HIGH RESISTANCE GROUNDING (HRG) UNIT TO AN ESP WITHIN A HAZARDOUS AREA 2014 EUALF

APPLICATION OF A HIGH RESISTANCE GROUNDING (HRG) UNIT TO AN ESP WITHIN A HAZARDOUS AREA 2014 EUALF APPLICATION OF A HIGH RESISTANCE GROUNDING (HRG) UNIT TO AN ESP WITHIN A HAZARDOUS AREA 2014 EUALF INTRODUCTION When conventional attempts to eliminate electrical discharge activity in a zone 1 hazardous

More information

George Karady (ASU), A. Huang (NCSU), M. Steurer (FSU)

George Karady (ASU), A. Huang (NCSU), M. Steurer (FSU) Y9.ET4.3: Fault Isolation Device (FID) Development - BIL Project Leader: Faculty: Students: Staff: Gerald Heydt (ASU) George Karady (ASU), A. Huang (NCSU), M. Steurer (FSU) Xuening Rong (ASU), Dongdong

More information

Lightning transient analysis in wind turbine blades

Lightning transient analysis in wind turbine blades Downloaded from orbit.dtu.dk on: Aug 15, 2018 Lightning transient analysis in wind turbine blades Candela Garolera, Anna; Holbøll, Joachim; Madsen, Søren Find Published in: Proceedings of International

More information

Exploring the Necessity of the Hot Hipot Test

Exploring the Necessity of the Hot Hipot Test Exploring the Necessity of the Hot Hipot Test Introduction In an industry comprised of workers with varying electronics knowledge, a Hipot test can seem a daunting task for some. Indeed, many test operators

More information

Instruction Manual for Digital Grounding Resistance Meter

Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Table of Contents I. Overview...2 II. Open-case Inspection...3 III. Safety Precautions...4

More information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL 600A AC Clamp Meter + NCV Model MA610 USER MANUAL 600A AC Clamp Meter + NCV Model MA610 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech MA610 Clamp Meter. This meter measures

More information

Busbars and lines are important elements

Busbars and lines are important elements CHAPTER CHAPTER 23 Protection of Busbars and Lines 23.1 Busbar Protection 23.2 Protection of Lines 23.3 Time-Graded Overcurrent Protection 23.4 Differential Pilot-Wire Protection 23.5 Distance Protection

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 15848-2 Second edition 2015-06-01 Industrial valves Measurement, test and qualification procedures for fugitive emissions Part 2: Production acceptance test of valves Robinetterie

More information

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd. MT-3110 3 5/6 Smart Digital Clamp Meter User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd. 1.Safety Information Warnings Special attention shall be paid when using the meter, improper

More information

Safety Issues Caused by High Earth Resistance and Identifying Them Using Instruments

Safety Issues Caused by High Earth Resistance and Identifying Them Using Instruments Safety Issues Caused by High Earth Resistance and Identifying Them Using Instruments Thomas Szollossy Senior Technical Support Engineer Power Quality Thailand PQSynergy 2017, Chiang Mai, Thailand Introduction

More information

ECE 528 Understanding Power Quality

ECE 528 Understanding Power Quality ECE 528 Understanding Power Quality http://www.ece.uidaho.edu/ee/power/ece528/ Paul Ortmann portmann@uidaho.edu 208-316-1520 (voice) 1 Today Wiring and grounding Why it s important References Terms and

More information

System Protection and Control Subcommittee

System Protection and Control Subcommittee Power Plant and Transmission System Protection Coordination Reverse Power (32), Negative Sequence Current (46), Inadvertent Energizing (50/27), Stator Ground Fault (59GN/27TH), Generator Differential (87G),

More information

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS 1.0 SCOPE 2.0 BONDING METHODS 2.1 Introduction 2.2 Design 2.3 Single-Point Bonding 2.4 Cross Bonding 2.5 Sheath Sectionalizing Joints 2.6 Sheath Standing Voltage 2.7 Sheath Voltage at Through Fault 2.8

More information

74ACT11652 OCTAL BUS TRANSCEIVER AND REGISTER WITH 3-STATE OUTPUTS

74ACT11652 OCTAL BUS TRANSCEIVER AND REGISTER WITH 3-STATE OUTPUTS 74ACT62 Independent Registers and Enables for A and B Buses Multiplexed Real-Time and Stored Data Flow-Through Architecture Optimizes PCB Layout Center-Pin V CC and Configuratio Minimize High-Speed Switching

More information

Simple Power IC for the Switched Current Power Converter: Its Fabrication and Other Applications March 3, 2006 Edward Herbert Canton, CT 06019

Simple Power IC for the Switched Current Power Converter: Its Fabrication and Other Applications March 3, 2006 Edward Herbert Canton, CT 06019 Simple Power IC for the Switched Current Power Converter: Its Fabrication and Other Applications March 3, 2006 Edward Herbert Canton, CT 06019 Introduction: A simple power integrated circuit (power IC)

More information

TN, TT & IT Earthing Arrangements

TN, TT & IT Earthing Arrangements TN, TT & IT Earthing Arrangements In IT and TN-C networks, residual current devices are far less likely to detect an insulation fault. In a TN-C system, they would also be very vulnerable to unwanted triggering

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer LF 510-S I PN = 500 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

Multifunction AC/DC Voltage Tester

Multifunction AC/DC Voltage Tester User Manual Multifunction AC/DC Voltage Tester Model 20250-59 THE STANDARD IN PRECISION MEASUREMENT 1065DGMAN_20250-59 DS multifunctional voltage tester.indd 1 8/8/2017 1:37:47 PM Introduction The Digi-Sense

More information

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS. Fourth Edition. Extracts from Amendment No.1: June 2011 NATIONAL RULES FOR ELECTRICAL INSTALLATIONS Fourth Edition ET 101:2008 Extracts from Amendment No.1:2011 22 June 2011 Page vi: Insert after 1 st Paragraph: Section 710: Medical Locations was prepared by

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 212475-CI3-1 CBDE1-52299/A1/M1 Date of issue...

More information

TEST REPORT IEC60950_1F. Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC60950_1F. Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-05-23 Page 1 of 9 Report Reference # 4787989179 Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment - Safety - Part 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207721-AS3-1 CB/DE1-55140 Date of issue...

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Current transducer LF 210-S/SP3 I PN = 100 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated

More information

Safety Barriers 2/1. Hazardous area. 250 V max I.S.

Safety Barriers 2/1. Hazardous area. 250 V max I.S. /0 Safety barriers Exchangeable back-up fuse for all safety barriers Snap-on mounting on rails: simultaneous connection to potential equalisation/ ground Simple selection: application specific single and

More information

High Voltage Component Production Testing with Two Model 2410 SourceMeter Units. Application Note Series. Introduction. Test System Configuration

High Voltage Component Production Testing with Two Model 2410 SourceMeter Units. Application Note Series. Introduction. Test System Configuration A Tektronix Company Application Note Series Number 2058 igh Voltage Component Production Testing with Two Model 2410 SourceMeter Units Introduction Various production test applications require the use

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

Agilent 1146A AC/DC Oscilloscope Current Probe

Agilent 1146A AC/DC Oscilloscope Current Probe A User s Guide Publication number 01146-92003 May 2005 Copyright Agilent Technologies 1996-2005 All Rights Reserved Contents Receiving Your Shipment -2 Packaging -2 Description -3 Compatibility -3 Control

More information

Unit WorkBook 1 Level 4 ENG U31: Electrical Systems and Fault Finding 2018 UniCourse Ltd. All Rights Reserved. Sample

Unit WorkBook 1 Level 4 ENG U31: Electrical Systems and Fault Finding 2018 UniCourse Ltd. All Rights Reserved. Sample Pearson BTEC Levels 4 Higher Nationals in Engineering (RQF) Unit 31: Electrical Systems and Fault Finding Unit Workbook 1 in a series of 4 for this unit Learning Outcome 1 Electrical Distribution Systems

More information

Reference Number PPS 05 - (RIC Standard: EP SP)

Reference Number PPS 05 - (RIC Standard: EP SP) Discipline Engineering Standard - NSW Category Electrical Title Low Voltage Isolating Transformer Reference Number PPS 05 - (RIC Standard: EP 17 00 00 11 SP) Document Control Status Date Prepared Reviewed

More information

Solid-state Twin Timer

Solid-state Twin Timer Solid-state Twin Timer -F Operates in flicker- or flicker- start mode with one Unit. Independent - and -time settings. Combinations of long - or -time and short - or -time setting are possible. Long time

More information

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit. Current Transducer LF 510-S I P N = 500 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and secondary circuit. Features Bipolar and insulated

More information

TS RES - OUTSTANDING ISSUES

TS RES - OUTSTANDING ISSUES TS RES - OUTSTANDING ISSUES This document has been officially issued as DRAFT until the following outstanding issues have been resolved. At that time the document will be officially reissued as the next

More information

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide

Agilent U1231A/U1232A/U1233A Handheld Multimeter. Quick Start Guide Agilent U3A/U3A/U33A Handheld Multimeter Quick Start Guide Verify that you received the following items in the shipment of your multimeter: One pair of red and black test leads Four.5 V AAA alkaline battery

More information

CHAPTER - 6 PIN DIODE CONTROL CIRCUITS FOR WIRELESS COMMUNICATIONS SYSTEMS

CHAPTER - 6 PIN DIODE CONTROL CIRCUITS FOR WIRELESS COMMUNICATIONS SYSTEMS CHAPTER - 6 PIN DIODE CONTROL CIRCUITS FOR WIRELESS COMMUNICATIONS SYSTEMS 2 NOTES 3 INTRODUCTION PIN DIODE CONTROL CIRCUITS FOR WIRELESS COMMUNICATIONS SYSTEMS Chapter 6 discusses PIN Control Circuits

More information

Use optocouplers for safe and reliable electrical systems

Use optocouplers for safe and reliable electrical systems 1 di 5 04/01/2013 10.15 Use optocouplers for safe and reliable electrical systems Harold Tisbe, Avago Technologies Inc. 1/2/2013 9:06 AM EST Although there are multiple technologies--capacitive, magnetic,

More information