Technical Data Sheets
|
|
- Brianne Blake
- 5 years ago
- Views:
Transcription
1 GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SG Series kva 400 Vac CE Series 0 Date of issue: SGSE_080_UPS_GE_01a SGSE_ _UPS_GE_01a SG Series 80 kva SG Series kva GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / F +41 (0)91 / GE imagination at work
2 GENERAL DATA Topology VFI, double conversion with integrated transformer Nominal output power at PF= lag. kva Overall efficiency at 100% load in VFI mode Overall efficiency at 75% load in VFI mode % Overall efficiency at 50% load in VFI mode Overall efficiency at 100% load in SEM mode % Heat dissipation at 100% load in VFI mode, PF=0.8 lag. and charged battery kw Cooling air (25 C 30 C) m 3 /h Audible noise level db(a) Battery type Valve regulated lead-acid (VRLA), vented lead-acid, NiCd Operating temperature range UPS: 0 C 40 C Storage temperature range -25 C +55 C Relative Humidity Max. 95% (non-condensing) Max. altitude without power derating Power derating (according to IEC ) 1000m 1500m: -5% / 2000m: -9% / 2500m: -14% / 3000m: -18% Protection degree IP 20 (IEC 60529) s EN / IEC 62040, CE marking EMC EN / IEC (Class A as option) Electrostatic discharge immunity 4kV contact / 8kV air discharge Internal protection All live parts shrouded Transport Cabinet suitable for handling by forklift Colour RAL 9003 (white) Installation Can be positioned against a wall and floor fixed Service access Front access only External cable connections Bottom or top, at right side of the cabinet Cooling Redundant fans Paralleling (RPA version) Up to 8 units parallelable for redundancy or capacity in RPA configuration (optional) RECTIFIER Rectifier bridge input voltage Other input voltages Input frequency Three phase, 6 thyristors, overtemperature protection Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 320V 460V (320V only for 405 VDC battery floating) On request 50/60 Hz +/-10% (45-66 Hz) 5 th harmonic filter 5 th + 11 th harmonic filter Power factor (with filter) Input current THD at nominal load (with filter) 8% 6% Inrush current Limited by soft-start circuit Power walk-in >30 seconds Output voltage tolerance +/- 1% DC voltage ripple <1% DC current ripple Max. 5% the battery capacity [Ah], expressed in A Battery charging characteristic IU (DIN 41773), T compensated floating voltage Battery charging current limit Programmable Input power data kva Input power at inverter nominal load and charged battery at PF=0.8 lag kw at PF=0.9 lag Max. input power at inverter nominal load and max. battery recharge current (programmable) kw Max. battery charging current (programmable) at at PF=0.8 lag A the beginning of battery recharge at nominal load at PF=0.9 lag Modifications reserved Page 2/5
3 BATTERY Battery type Valve regulated lead-acid (VRLA)-standard, Vented lead-acid, wet battery and NiCd Number of 12V blocks, 6 cells/block 30 to 32, placed in external cabinets (33 blocks on request) Float voltage at 20 C 405V 436V (dependent on the number of blocks) Min. discharge voltage (programmable) 1.65V / cell (1.60V / cell for 33 blocks) Recharge time <5 hours up to 90% of battery capacity Battery to earth fault detection Automatic and manual battery test Automatic battery contactor Battery power data kva DC power at full load and PF=0.8 lag. kw DC power at full load and PF=0.9 lag. kw DC power at full typical computer load (PF=0.66 lag.) kw Matching battery cabinets See optional features on page 4 INVERTER Nominal output power at PF= lag kva Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge SVM (Space Vector Modulation) and IGBT technology Output transformer (for galvanic separation) Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (at load step %)... +/- 2% - dynamic (at load step %)... +/- 1.5% - recovery time to +/-1% ms - output voltage THD for 100% linear load... Max. 1% - output voltage THD for 100% non-linear load (EN 50091) Max. 3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load : +/- 1% - at 100% unbalanced load : +/- 2% Overload capability (at PF=0.8) 125% - 10 minutes, 150% - 1 minute Short-circuit characteristic Electronic short-circuit protection, current limit to 2.2 times In for 200 ms MTCB clearance capability (selectivity) 20% In within 5-10 ms (with MTCB class C) Crest factor >3:1 BYPASS Input connection Primary components Voltage limits for inverter/bypass load transfers Overload on bypass Separate (dual input-recommended) or common to the rectifier input - Static switch (SCR) on bypass - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass +/- 10% (adjustable) 200% for 5 minutes & 45 times In for 10 ms, non repetitive INTERFACING 6 programmable signalling voltage-free contacts - information for easy integration and signalling (available on Delta and block terminals) - 27 user settable signals Serial channel RS232 (on Delta 9 pin connector) - EMERGENCY POWER OFF (n/c contact, customer supplied) Input signals - GEN ON (emergency power supply ON, n/o contact, customer supplied) - 2 auxiliary signals, with settable functionality Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 3/5
4 FRONT PANEL CONTROLS, SIGNALS AND ALARMS SYNOPTIC DIAGRAM OF THE UPS: Represents the operational status with integrated LEDs and power flow indicators. SERVICE CHECK (LED): Turns on when maintenance is due or when the UPS is Service mode. ALARM: Visual (LED) and audible signal (buzzer), active when an alarm condition is present. STOP OPERATION: Visual (LED) and audible signal (buzzer) active approx. 3 minutes before complete and automatic load dis-connection (due to an overtemperature condition or fully discharged battery). LOAD LEVEL, BATTERY AUTONOMY: Status indicator bar graphs. MONITORING SYSTEM with multi language LCD display and control keys. PUSH-BUTTONS: - INVERTER ON - INVERTER OFF - MUTE - LAMP TEST - TOTAL OFF (key with protective cover): to be pressed for emergency off. OPTIONS BUILT-IN UPS OPTIONS: 1. RPA kit 2. Auxiliary Power Supply (APS) 24VDC 3. Harmonic filters 4. EMC filters IEC Class A COMMUNICATION: 1. RSB - Remote Signalling Box (cable for connection to UPS not included) 2. Advanced SNMP Card 3. JUMP software suite 4. IRIS service 5. Modbus RTU Interface OPTIONS IN ADDITIONAL CABINETS: Dimensions (WxDxH): 800x300x 500x800x1820mm 800x800x1820mm 1200x800x1820mm 1. Rectifier and/or bypass transformer 2. Active Filter pulse rectifier with or without galvanic separation 4. Special voltages: input and/or output On request 5. Centralized maintenance bypass for RPA configuration On request 6. Empty battery cabinets External accessories: 1. External battery fuses box On request Modifications reserved Page 4/5
5 TECHNICAL DATA WEIGHTS (kg) SG Series 80 kva UPS cabinet Additional cabinet (500x800x1820) SG Series 100 & 120 kva 1'820mm UPS rating UPS standard EMC filter 5 th harmonic filter 5 th + 11 th harmonic filter Rectifier and/or bypass transformer 12 pulse without galvanic separation 12 pulse with galvanic separation 80 kva (6 pulse) '820mm 1'850mm 80 kva (12 pulse) kva (6 pulse) SGSE_080_UPS dimension_ge_ kva (12 pulse) kva (6 pulse) kva (12 pulse) SGSE_ _UPS dimension_ge_01 1'200mm Note: Single weights have to be added up for system configuration to get the total weight! UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass K6 SGSE_Block diagram common input_01 SSM Q2 B L1/L2/L3/N F2 Separated input (recommended) Rectifier & Bypass K6 SGSE_Block diagram separate input_ K4 K F3 Q1 Q1 E D K7 F1 K7 C K K A K 7 K F4 F4 7 1 = Rectifier 3 = Electronic Bypass 5 = Mains 7 = External Battery 2 = Inverter 4 = Manual Bypass 6 = Load F4 = External Battery Fuses Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V SSM Protections and cable sections Cable sections A, B, C, D, E and K Recommended by European s Alternatively, local standards to be respected Fuses AgL or equivalent MTCB Cable sections (mm 2 ) kva F1 F2 F3 F4 A B C and E D K 80 3 x 160A 3 x 125A 3 x 160A 2 x 250A 3 x x 35 4 x x x x 200A 3 x 160A 3 x 200A 2 x 315A 3 x x 50 4 x x x x 250A 3 x 200A 3 x 250A 2 x 355A 3 x x 70 4 x x x SEV / ASE cable sections recommended in Switzerland (mm 2 ) kva A B C and E D K 80 3 x x 50 4 x x x F1, F2, F3, F4, A, B, C, D, E, K: supplied by customer x x 70 4 x x x F4: can be supplied by GE x x 95 4 x x x IMPORTANT NOTE! The UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 4 pole breaker shall not be used at the UPS input (see also IEC 60634, IEC 61140, IEC 61557). Q2 Modifications reserved Page 5/5
Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V
Technical Data Sheet Uninterruptible Power Supply On-line VH Series UPS 2000-3000 UL / 208V GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850
More informationTECHNICAL DATA SHEET B9600FXS kva
GENERAL INFORMATION TECHNICAL DATA SHEET B9600FXS 400-500-600-800 kva UPS Type ON LINE - Double Conversion Nominal output power (Cos 0.9) kva 400 500 600 800 Nominal output power (Cos 1.0) kw 360 450 540
More informationW o r l d C l a s s P o w e r S o l u t i o n s Internal power supply UPS mains operation UPS battery operation Bypass operation Parallel operation Manual bypass Overload Inverter failure Mains failure
More informationGutor PxW AC UPS Designed for North American Market
Gutor PxW AC UPS Designed for North American Market PEW 5 200 kva single phase PDW 10 220 kva three phase Higher ratings upon request schneider-electric.com 2 schneider-electric.com schneider-electric.com
More informationG8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN
UNINTERRUPTIBLE POWER SYSTEMS PF >0.98 G8000MM Series 100 to 750 KVA UPS IGBT DESIGN 94% Efficiency Main Features State-of-the-Art Modular Design Provides Maximum Flexibility The Toshiba G8000MM Uninterruptible
More informationMODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division
MODULAR DC POWER SUPPLIES & SYSTEMS DC Power Systems DC/AC Inverters Static Switches DC/DC Converters GAMATRONIC, A SolarEdge Division 17 Hartom Street, Jerusalem 9777517, Israel 1-800-20-70-90 Tel: +972-2-5888277
More informationTOSHIBA International Corp
TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification
More informationPRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS
PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS GAMATRONIC ELECTRONIC INDUSTRIES LTD. 1. Introduction Founded in 1970, Gamatronic
More informationR&D TECHNICAL SPECIFI
INTRODUCTION Present document defines technical specs of a three phase UPS covering the power range from 20 to 30 kva ON-LINE DOUBLE CONVERSION Uninterruptible Power Supply Systems with forced ventilation
More informationThese true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.
Industrial Inverter The Gentec inverter systems, OND2 SERIES, provide safe, pure sine wave, reliable power to critical control equipment. These inverters are online type, usually the load is fed by the
More informationDale Power Solutions Ltd
DC SWITCH TRIPPER CHARGER DATASHEET Features Erskine STU 110W Range 24V, 30V, or 48VDC nominal Constant voltage current limited charger output Standard alarms LCD voltmeter LED indica ons Equipped with
More informationTechnical Specifications
Technical Specifications Master MPS 10 to 80 kva THREE-PHASE INPUT / THREE-PHASE OUTPUT 10 to 100 kva THREE-PHASE INPUT / SINGLE-PHASE OUTPUT On Line Double Conversion (VFI) Technology with Isolated Inverter
More informationThese true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.
Three-phase Industrial Inverter OND4 SERIES The new OND4 SERIES inverter provides safe, pure sine wave, single-phase or three-phase reliable power to critical control equipment. These inverters are of
More informationSG-CE Series PurePulse
GE Digital Energy Power Quality SG-CE Series 100-120 kva PurePulse SG-CE Series 60-80 kva PurePulse SGSE_060-120_S1_UPS_GE_01 Digital Energy SG-CE Series PurePulse 60 80 100 120 400 ~ CE / Series 1 GE
More informationChloride FP-60Z 5 to 60kVA
Chloride FP-60Z 5 to 60kVA AC UPS system catalogue - FP-60Z31 and FP-60Z33 Industrial Power for Business-Critical Continuity Chloride FP-60Z 5 to 60kVA AC UPS system - FP-60Z31 and FP-60Z33 Scope 4 General
More informationPROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business
PROTECT 8 INDUSTRIAL UPS Protect 8.31 Single Phase output 10 kva 80 kva Protect 8.33 Three Phase output 10 kva 120 kva 400 VAC input 216 VDC link 384 VDC link Engineering is our business UPS systems from
More information2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.
1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the
More informationEst Static Frequency Converter. SFX 10kVA - 10MVA
Est.1968 Static Frequency Converter SFX 10kVA - 10MVA Static Frequency Converter SFX 10kVA - 10MVA A Concept Thycon Static Frequency Converters (SFX) convert supply frequency to load requirement frequency.
More informationMITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS
MITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS Copyright Mitsubishi Electric Power Products TABLE OF CONTENTS 1. SCOPE... 1 1.1 The System... 1 2. SYSTEM DESCRIPTION... 1 2.1 Components... 1 2.2 Modes
More informationGESS Industrial UPS System. Overview
GESS Industrial UPS System Overview Industrial UPS System Rectifier with Isolation Transformer Inverter with Isolation Transformer By-pass line Voltage Stabilizer with Isolation Transformer > Individual
More informationG-NET. 1 kva-10 kva. Rack & Tower UPS
G-NET 1 kva-10 kva Rack & Tower UPS G-NET 1 kva-10 kva Rack & Tower UPS The G-Net Rack & Tower series of UPS systems is a line of advanced true online UPSs which provide clean, reliable and regulated AC
More informationB9000 FXS kVA B9600 FXS kVA
OF CONTINUOUS SERVICE YEARS WARRANTY B9000 FXS 60-300kVA B9600 FXS 400-800kVA BORRI B9000 FXS B9600 FXS With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS
More informationSENTINEL XR PLUS 5-10kVA
SENTINEL R PLUS 5-10kVA Uninterruptible Power Supply Absolute protection Sentinel R Plus is the ideal solution for powering vital mission critical, sensitive loads such as electro-medical security applications
More informationTable K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220
Table K. Input/ Ratings & External Wiring Requirements for the 9390-/ Units Rating 50/0 Hz Basic Unit Rating at 0.9 lagging pf load Input and Bypass Input Rectifier (0.98 min. pf) plus Recharge Current
More informationOPUS C DC Power Systems OC2066 and OC1666 floor standing Cabinets
OPUS C OPUS C DC Power Systems OC2066 and OC1666 floor standing Cabinets 6.6 OPUS C 220- OPUS C 220- Product Description Features OPUS C DC power systems are robust, free convection cooled, N+1 redundant
More informationSECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM
SECTION 263353 - THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM PART 1 GENERAL 1.1 SUMMARY A. This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty three-phase,
More informationLiebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS
Liebert Hipulse-U Fully Digital Dual DSP Controlled Transformer Based UPS Addressing a Variety of Needs The Liebert Hipulse-U offers a reliable, scalable and user-friendly solution to ensure availability
More informationMAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
More informationEst Static Frequency Converter. SFX 10kVA - 10MVA
Est.1968 Static Converter SFX 10kVA - 10MVA Concept Thycon Static Converters (SFX) convert supply frequency to load requirement frequency. Typical applications are 50 to 60Hz conversion for naval and 50
More informationSeries 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M
Power Protection for Business Critical Continuity Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications Compact Three-phase UPS with Optimum Load Performance And
More information1KVA-2KVA-3KVA 6KVA-10KVA. NUPS22 Series
1KVA-2KVA-3KVA 6KVA-10KVA NUPS22 Series Niveo Professional True Sine Wave Double-Conversion Online Rack/Tower UPS NUPS22-1000U- 1.0KVA/900W NUPS22-2000U-2.0KVA/1800W NUPS22-3000U- 1.0KVA/2700W NUPS22-6000U
More informationSeries PCI + PIT PIT5738 U IN PIT5748 U IN PCI5748 PCI5738. Series PIT 19 - Cabinet G10
PCI + PIT PCI5728 U IN 20 32 PIT5738 U IN 40 64 PIT5748 U IN 50 80 PIT5658 U IN 80 160 PIT5678 3000VA 3000VA 3000VA 3000VA 3000VA Serie PCI5728 U IN 20 32 PCI5738 U IN 40 64 PCI5748 U IN 50 80 PCI5758
More informationChloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA. AC Power For Business-Critical Continuity
Chloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA AC Power For Business-Critical Continuity A Commitment to Best-in-Class Technologies When it comes to protecting critical
More informationGUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL
1.1 SUMMARY Liebert NX UPS GUIDE SPECIFICATIONS 40-80kVA, 80-120kVA and 160-200kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL This specification defines the electrical and mechanical
More informationSPECIFICATION. Online UPS 3000VA
Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationDIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES
MAIN APPLICATIONS DIGITAL SWITCH MODE POWER SUPPLIES GENERAL INTRODUCTION TO QP SERIES The new generation of Digital Switch Mode Power Supplies F series QP, has been designed and is manufactured by SALICRU
More informationSTATIC UNINTERRUPTIBLE POWER SYSTEM Revised 4/30/ Electrical Systems
SECTION 26 33 53 - STATIC UNINTERRUPTIBLE POWER SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty three-phase,
More informationStatiVolt. Inverter UPS Systems. Features. Contents
Redundant, clean, sine-wave AC power ensures a high availability of mission-critical safety devices, instrumentation, alarms, controls and computers. Robust, StatiVolt UPS Systems are designed and built
More informationS11 Adjustable Speed Drive Engineering Specification
PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba S11 AC Variable Frequency Drives, 6 pulse for 3- phase 200-240VAC, 380-500VAC and single phase 200V to 240VAC. 1.1 References A. National
More informationTEST REPORT IEC Uninterruptible power systems Part 3: Method of specifying the performance and test requirements
Test Report issued under the responsibility of: TEST REORT IEC 62040-3 Uninterruptible power systems art 3: Method of specifying the performance and test requirements Report reference No...: 11-EL-0026.06
More informationRELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD
RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES Power Management Instruments FROM PMI & OES GROUP COMPANIES SUD Today, as technology evolves, Electrical, Electronic and Electromechanical devices are
More informationLCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans
LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis
More informationBAT-Series Grid Inverter. Battery Charger.
BAT-Series Grid Inverter. Battery Charger. With the BAT-series, WSTECH offers a wide range of power converters for small to large energy storage applications. The BAT-series inverters offer a power range
More informationPURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05
PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05 Kert is always ready to help you! If you need: Advices
More informationResilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc
Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc Product Description The Resilient 3000 is a high Efficiency, single phase, general purpose and ruggedized fan cooled rectifier for stand alone
More informationUNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49
TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact
More informationLiebert THE NEW LEADER IN THREE-PHASE UPS PRODUCT. Npower. 30 to 130 kva. True Double Conversion. Exceptional Reliability. Unmatched Performance
Liebert Npower 30 to 130 kva P o w e r A v a i l a b i l i t y THE NEW LEADER IN THREE-PHASE UPS PRODUCT True Double Conversion Exceptional Reliability Unmatched Performance High-Availability Configurations
More informationAXA 2400 COMPACT & 90 kva solid-state GPU
AXA 2400 COMPACT 30-45-60 & 90 kva solid-state GPU AXA POWER is part of ITW GSE the world s leading supplier of Ground Support Equipment It s all about connections OPTIMAL POWER AT THE AIRCRAFT At ITW
More informationPURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES
PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES Kert is always ready to help you! If you need: Advices for the purchase
More informationCROSS Chassis from 160 A to 450 A
CROSS Chassis from 160 A to 450 A STS CATALOGUE Important note! The technical data enclosed is for general information. Please note that the operating instructions and references indicated on the products
More informationOrbital GFI Inverter Series
Orbital GFI Inverter Series Datasheet Key Features One, split or three phases and up to 25 kva Superior efficiency of 95% CAN Bus control and DAQ Power quality and EMC compliance in accordance with European
More informationEL-AC Electronic Load
s are power electronics devices that behave as an electrical load. While most electronic loads are dissipative, CINERGIA offers a comprehensive range of, and & full 4Q and full regenerative electronic
More informationSM2000 TECHNICAL DESCRIPTION
SM2000 TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The SM2000 module is a high frequency switch mode rectifier. It converts the single phase AC line voltage into an isolated DC voltage. It can be used
More informationChloride. FP-50z 5 160kVA Industrial AC UPS
Chloride FP-50z 5 160kVA Industrial AC UPS CHLORIDE FP-50Z Features yfully digital UPS solution for industrial applications yrobust design ensure high reliability features yuser-friendly display ydesign
More informationTechnical Data Sheet AMIK 300 / 301
USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important
More informationSide view View from below Rear view
Dimension diagrams All dimensions in mm Side view View from below Rear view Cut out: 138 +0,8 x 138 +0,8 mm Typical connection SPS SPS 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 DSUB-9 5 4 3 2 1 8 7 6 5 4
More informationProduct Catalog PRODUCT CATALOG. Power supply system & test equipment
Product Catalog PRODUCT CATALOG 2018 2018 Power supply system & test equipment. 138/79, Moo 2 Tambon Ban Klang, Amphoe Mueang Pathumthani, Pathumthani Province 12000, Thailand. Tel: +66 21475048-9 Fax:
More informationTable G. INPUT/OUTPUT Ratings & External Wiring Requirements for the /160 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220
Table G. INPUT/OUTPUT Ratings & External Wiring Requirements for the 9390/ Units Rating 50/60 Hz Basic Unit Rating at 0.9 lagging pf load Input and Bypass Input A Input to UPS Rectifier (0.98 min. pf)
More informationUNINTERRUPTIBLE POWER SUPPLY SPECIFICATIONS MODEL 1100B SERIES
UNINTERRUPTIBLE POWER SUPPLY MODEL 1100B SERIES SPECIFICATIONS In no event shall MEPPI be liable for the accuracy, completeness or usefulness of the following specifications or for any modification(s)
More informationSHORE TO SHIP FREQUENCY
POWER SYSTEMS INTERNATIONAL SHORE POWER POWER CONVERSION SYSTEMS 50Hz, 60Hz and 400Hz three phase and single phase There is a growing world focus on energy conservation with the drive towards reducing
More informationPower IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics
Power IT LV Active Filters PQFI PQFM PQFK The ABB comprehensive solution for active filtering of harmonics Harmonics and Power Quality Power Quality relates to the amplitude, frequency and distortion of
More informationALL PRODUCT BROCHURE
ALL PRODUCT BROCHURE AMETEK Solidstate Controls is a recognized leader in the manufacturing of industrial power equipment. We provide continuity of electrical power to businesses by designing industrial
More information70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL CIRCUIT TOPOLOGY...2
SNP-Z077 Specification Page 1 of 7 70 Watt Switching Medical Grade Switching Power Supply with Active PFC CONTENTS 1. GENERAL...2 2. CIRCUIT TOPOLOGY...2 3. AC INPUT...2 3.1. INPUT VOLTAGE...2 3.2. INPUT
More informationFCL VOLTAGE & FREQUENCY CONVERTERS. FCL H SERIES - SINGLE PHASE - 2 to 30 kva H SERIES MODELS. AC SINGLE PHASE 2 TO 30 kva STATIC VARIABLE AC
STATIC VARIABLE AC VOLTAGE & FREQUENCY CONVERTERS AC SINGLE PHASE 2 TO 30 kva IGBT SOLID STATE PWM DESIGN MODELS INPUT: 22-23 - 24 - OUTPUT: - 40 70Hz FCL 22 / 23 / 24-2 WIRE SINGLE PHASE THE UNIVERSAL
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationTypes VIS and CRE. A e. Compliance with Standards. Uses. Features
Fig. 1 Pure Sine Wave IGBT Controlled CCRs Types VIS and CRE Compliance with Standards FAA: AC 150/5345-10 (current edition), L-828, L-829 except for input voltage ICAO: Aerodrome Design Manual Part 5,
More informationDSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.
15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty
More informationCOMPANY. GCRDC Lifter Gear Converter 12Vcc, 24Vcc, 48Vcc, 400VA GRDC Linear Converter DC/DC 13.8Vcc, 40AVcc 560W
COMPANY The company was established in 1979 and dedicated to the control of power electronics. We develop and manufacture tailor-made power supplies and dispose of standard products. We can work together
More informationVF-nC1 Adjustable Speed Drive Engineering Specification
PART 1 - GENERAL 1.0 Scope This specification shall cover Toshiba VF-nC1 AC Variable Frequency Drives, 6 pulse for 100V single-phase 0.1 to 0.75kW, 200V single-phase 0.2 to 2.2kW and 200V threephase 0.1
More informationApplication Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters
Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel
More informationPower IT LV Active Filters PQFA - PQFL - PQFT
Power IT LV Active Filters PQFA - PQFL - PQFT The ABB comprehensive solution for active filtering of harmonics Pst Harmonics and Power Quality Harmonics caused by non-linear electrical loads such as variable
More informationRISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:
(With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network
More informationSystem configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.
~ ~ SX High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards
More informationType 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs
Function have all the same advantages as the 3RW30/31 soft starters. At the same they come with additional functions and a two-phase control method (Polarity Balancing) that is unique in the rating range
More informationBuilt To Order 3 Phase UPS Systems
Built To Order 3 Phase UPS Systems Features Of Built To Order 3 Phase Systems True Galvanic solation Solves all major power problems including electrical noise, surges, brown outs, and leakage current.
More informationALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationThe world is changing but our power is constant...
The world is changing but our power is constant...... Su-Kam Online UPS Su-Kam Power Systems Ltd. Corporate Office: Plot No. 54, Udyog Vihar Phase VI, Sector-37, Gurgaon-122001, Haryana, India. Tel.:+91-124-4030700,4170500,Fax:+91-124-4038700/1/2.
More informationPowerLogic power-monitoring units. PM700 series power meter. Technical data sheet
PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More informationEnergy Management Three-phase energy meter with output modules Type EM4-DIN
Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT
More informationPlease note and refer to warning marks which you will find in the unit.
Table of contents 1.0 Preface ---------------------------------------------------------------------------------------- 1-1 1-1 Introduction ----------------------------------------------------------------------------
More information4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA
PERFORMANCES High accuracy High stability Fast transients High inrush current facilities Wide bandwidth 25 khz at -3dB Internal waveform DC and up to 10 khz Very low distortion Quadrant change without
More informationATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink
Characteristics variable speed drive ATV12-4kW - 5hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly
More information2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES
2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES Medium-voltage rack-mount power supplies Page 2 The MV2000 series high-performance, medium output
More informationATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol
Product datasheet Characteristics ATV12HU22M2 Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component name Variable
More informationOPTI-UPS User s Guide
OPTI-UPS User s Guide Durable Series Models DS-D33 www.opti-ups.com Contents Page 1. SYSTEM OVERVIEW... 1-1 1.1. Construction of the UPS... 1-1 1.2. Features and Advantages... 1-5 1.3. Rectifier... 1-8
More informationEnergy Management Energy Meter with plug-in Output Modules Type EM4-DIN
Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse
More informationINTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]
Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High
More informationAMIK 200 / 201 Technical Data Sheet
AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT
More informationATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW
Characteristics soft starter for asynchronous motor - ATS01-25 A - 110..480V - 2.2..11 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application Device
More informationATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW
Characteristics soft starter for asynchronous motor - ATS01-12 A - 110..480V - 1.5..5.5 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More informationPower supply CP-T 24/20.0 Primary switch mode power supply
Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,
More informationD SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE
D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE 1 2 SERIES 1 2 pag. 4 pag. 5 Applications Model identification 3 pag. 5 4 pag. 6 Capacity
More informationATV12H018F1 variable speed drive ATV kW hp V - 1ph
Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 100..120V - 1ph Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly style Component
More informationATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink
Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application
More informationUninterruptible Power System (UPS) 20 to 320 kva
Large-capacity Uninterruptible Power System (UPS) 20 to 320 kva All IGBT type UPS 7000F Series REC 82-5 Fuji's UPS for today's computerized On-line support for all applications Data communication devices
More informationEnergy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications
Energy Management Multifunction indicator Type WM12-DI Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase measurements:
More informationMedical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3
HPU1K5 Series Low Profile 1.7 (43.2 mm), Industrial Supply Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals Output Power up to 1500 W Load dependant variable speed fans for audible
More informationATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW
Characteristics soft starter for asynchronous motor - ATS01-3 A - 110..480V - 0.55..1.1 KW Main Range of product Altistart 01 Product or component type Product destination Product specific application
More information