Record Adoption of ASTM E b as an Update of SE Nov-12 Page 1 of 5

Size: px
Start display at page:

Download "Record Adoption of ASTM E b as an Update of SE Nov-12 Page 1 of 5"

Transcription

1 17-Nov-12 Page 1 of 5 From Article 2, Mandatory Appendix V V-220 GENERAL REQUIREMENTS (a) The Standard Terminology for Nondestructive Examinations (ASTM E1316) has been adopted by the Committee as SE SE-1316, Section 7 provides the definitions of terms listed in V-230(a). Revise Section 7 to Section D in paragraph (c) For general terms, such as Indication, Flaw, Discontinuity, Evaluation, etc., refer to (d) Paragraph V-230 provides a list of terms and definitions that are Code specific. Paragraph V-230(c) provides a list of terms and definitions that are specific to Section V, Article 2, Appendix VI. V-230 REQUIREMENTS conjunction with this Article: analog image, back scattered radiation, cassette, composite viewing, contrast sensitivity, contrast stretch, densitometer, density (film), digital, digital image, digitize, digital image acquisition system, erasable optical medium, focal spot, fog, geometric unsharpness, image processing, intensifying screen, IQI sensitivity, line pair per millimeter, line pair test pattern, location marker, luminosity, magnetic storage medium, optical density, photostimulable luminescent phosphor, pixel, pixel size, recording media, screen, source, stepwedge, system-induced artifacts, transmission densitometer, and transmitted film density. Change density (film) to film density and move to fit in alphabetically Make the following editorial correction: line pairs per millimeter Delete terms transmission densitometer and transmitted film density

2 17-Nov-12 Page 2 of 5 From Article 6, Mandatory Appendix I I-620 GENERAL REQUIREMENTS (a) The Standard Terminology for Nondestructive Examinations (ASTM E1316) has been adopted by the Committee as SE SE-1316 Section G provides the definitions of terms listed in I-630(a). Revise Section G to Section F in paragraph (c) For general terms, such as Indication, Flaw, Discontinuity, Evaluation, etc., refer to (d) Paragraph I-630 provides a list of terms and definitions which are in addition to SE-1316 and are Code specific. I-630 REQUIREMENTS conjunction with this Article: blacklight; bleedout; blotting; clean; contaminant; contrast; developer; developer, aqueous; developer, dry; developer, nonaqueous; developing time; drying time; dwell time; emulsifier; family; fluorescence; overemulsification; penetrant; penetrant comparator; penetrant fluorescent; penetrant, water washable; post-cleaning; postemulsification; precleaning; rinse; solvent remover. Make the following editorial correction: developer, dry powder

3 17-Nov-12 Page 3 of 5 From Article 8, Mandatory Appendix I I-820 GENERAL REQUIREMENTS (a) This standard terminology for nondestructive examination ASTM E1316 has been adopted by the Committee as SE SE-1316, Section 6, Electromagnetic Testing, provides the definitions of terms listed in I-830(a). Revise Section 6 to Section C in paragraph (c) For general terms, such as Interpretation,Flaw, Discontinuity, Evaluation, etc., refer to (d) Paragraph I-830 provides a list of terms and definitions, which are in addition to SE-1316 and are Code specific. I-830 REQUIREMENTS conjunction with this Article: absolute coil, differential coils, eddy current, eddy current testing, frequency, phase angle, probe coil, reference standard, standard. Delete terms frequency, reference standard, standard

4 17-Nov-12 Page 4 of 5 From Article 9, Mandatory Appendix I I-920 GENERAL (a) Article 30, SE-1316, Section 9, provides the definition of footcandle (fc). Revise Section 9 to Section F in paragraph (a) Definitions of terms for visuale xamination and other methods appear in Article 1, Mandatory Appendix I, Glossary of Terms for Nondestructive Examination.

5 17-Nov-12 Page 5 of 5 From Article 10, Mandatory Appendix VII VII-1020 GENERAL (a) ASTM E1316, Standard Terminology for Nondestructive Examinations, has been adopted by the Committee as SE SE-1316 Section 8 provides the definitions of terms listed in (e). Revise Section 8 to Section E in paragraph

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Film Replacement in Radiographic Weld Inspection The New ISO Standard BAM Berlin Film Replacement in Radiographic Weld Inspection The New ISO Standard 17636-2 Uwe Ewert, Uwe Zscherpel, Mirko Jechow Requests and information to: uwez@bam.de 1 Outline - The 3 essential parameters

More information

Engineering Policy & Procedure

Engineering Policy & Procedure FPD > Engineering > Global Standards Engineering Policy & Procedure Revision History Number: G2-4 Section: G Subject: Radiographic Examination Procedure 1.0 SCOPE This procedure specifies the requirements

More information

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light. Radiology د. اريج Lec. 3 X Ray Films Radiograph: Is the image of an object made with use of X- ray instead of light. Dental x- ray film: Is a recording media on which image of the object was made by exposing

More information

Welding Inspection Non-Destructive Testing Course Reference WIS 5

Welding Inspection Non-Destructive Testing Course Reference WIS 5 Welding Inspection Non-Destructive Testing Course Reference WIS 5 Non Destructive Testing A welding inspector should have a working knowledge of NDT methods and their applications, advantages and disadvantages.

More information

NDT-PRO Services expands service offering

NDT-PRO Services expands service offering NDT-PRO Services expands service offering NDT-PRO Services announced the formal release of two advanced NDT methods, Phased Array (including TOFD) and Eddy Current. What are they and where are the used?

More information

NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I

NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I 1.What do you mean by Non-Destructive Testing (NDT)? Inspecting or testing the materials and components in such a way that allows the materials

More information

Radiographic testing: Increased detection sensitivity using optimum source to object distance

Radiographic testing: Increased detection sensitivity using optimum source to object distance 18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa Radiographic testing: Increased detection sensitivity using optimum source to object distance Jan Hendrik COWAN

More information

LECTURE 1 The Radiographic Image

LECTURE 1 The Radiographic Image LECTURE 1 The Radiographic Image Prepared by:- KAMARUL AMIN ABDULLAH @ ABU BAKAR UiTM Faculty of Health Sciences Medical Imaging Department 11/23/2011 KAMARUL AMIN (C) 1 Lesson Objectives At the end of

More information

NDE SOLUTIONS RADIOGRAPHY COURSE OUTLINE

NDE SOLUTIONS RADIOGRAPHY COURSE OUTLINE NDE SOLUTIONS RADIOGRAPHY COURSE OUTLINE 80 Hour Course Length 1.0 NDT Qualification and Introduction (3 Hours) 1.1 NDT Introduction 1.2 NDT Qualification and Certification 1.2.1 NAS 410 1.2.2 SNT-TC-1A

More information

Standard Practice for Qualification of Radioscopic Systems 1

Standard Practice for Qualification of Radioscopic Systems 1 Designation: 95 An American National Standard Standard Practice for Qualification of Radioscopic Systems 1 This standard is issued under the fixed designation ; the number immediately following the designation

More information

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images. DIGITAL RADIOGRAPHY Digital radiography is a film-less technology used to record radiographic images. 1 The purpose of digital imaging is to generate images that can be used in the diagnosis and assessment

More information

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS Course Number: RADG 112 Department: Radiography Course Title: Image Production & Eval. Semester: Spring Year: 1997 Objectives/ Unit One: Introduction

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors INTERNATIONAL STANDARD ISO 17636-2 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors Contrôle non destructif des

More information

Amorphous Selenium Direct Radiography for Industrial Imaging

Amorphous Selenium Direct Radiography for Industrial Imaging DGZfP Proceedings BB 67-CD Paper 22 Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15-17, 1999, Berlin, Germany Amorphous Selenium Direct Radiography for Industrial

More information

RADIOGRAPHIC EXAMINATION PROCEDURE

RADIOGRAPHIC EXAMINATION PROCEDURE Page 1 of 19 Doc. No. KNS/RT/01.REV 0 RADIOGRAPHIC EXAMINATION PROCEDURE Page: 19 of 19 Date: 15.09.2012 RADIOGRAPHIC EXAMINATION PROCEDURE PREPARED & APPROVED BY NDE- Level III CERTIFIED BY REVIEWED BY

More information

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology

SYLLABUS. TITLE: Equipment Operation I. DEPARTMENT: Radiologic Technology CODE: RADT 156 INSTITUTE: Health Science TITLE: Equipment Operation I DEPARTMENT: Radiologic Technology COURSE DESCRIPTION: This course covers the principles of equipment operation and maintenance of radiographic

More information

Computed Radiography

Computed Radiography BAM Berlin Computed Radiography --INDE 2007, Kalpakkam, India -- Uwe Zscherpel, Uwe Ewert BAM Berlin, Division VIII.3 Requests Requests and and information information to: to: Dr. Dr. U. U. Zscherpel Zscherpel

More information

Recommended Training Curriculum For Digital Radiography Personnel (Level II)

Recommended Training Curriculum For Digital Radiography Personnel (Level II) Paper No. 005-11 Recommended Training Curriculum For Digital Radiography Personnel (Level II) 1 December 2011 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction

More information

SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS

SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS Robert Edward Lee Electron Microscopy Center Department of Anatomy and Neurobiology Colorado State University P T R Prentice Hall, Englewood Cliffs,

More information

X-rays in medical diagnostics

X-rays in medical diagnostics X-rays in medical diagnostics S.Dolanski Babić 2017/18. History W.C.Röntgen (1845-1923) discovered a new type of radiation Nature, Jan. 23. 1896.; Science, Feb.14. 1896. X- rays: Induced the ionization

More information

Standard Practice for Radiographic Examination 1

Standard Practice for Radiographic Examination 1 Designation: E 1742 00 An American National Standard Standard Practice for Radiographic Examination 1 This standard is issued under the fixed designation E 1742; the number immediately following the designation

More information

In-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing

In-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing ISO 2016 All rights reserved ISO/TC 85/SC 6 N 230 Date: 2017-01-12 ISO/CD 20890-6:2016(E) ISO/TC 85/SC 6/WG 3 Secretariat: ANSI In-service inspections for primary coolant circuit components of light water

More information

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. RA110 test 3 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. An object 35 cm in width is radiographed at 100 cm SID and at a 50 cm SOD. What

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 16371-1 First edition 2011-10-01 Non-destructive testing Industrial computed radiography with storage phosphor imaging plates Part 1: Classification of systems Essais non destructifs

More information

American University of Beirut Faculty of Health Sciences Medical Imaging Sciences MIMG 203. (Medical Imaging Equipment I) Fall Semester

American University of Beirut Faculty of Health Sciences Medical Imaging Sciences MIMG 203. (Medical Imaging Equipment I) Fall Semester American University of Beirut Faculty of Health Sciences Medical Imaging Sciences (Medical Imaging Equipment I) Fall Semester P 1 of 6 Name Marlen S. Keushgerian Office Hours: Meeting Location Office Location:

More information

CR Basics and FAQ. Overview. Historical Perspective

CR Basics and FAQ. Overview. Historical Perspective Page: 1 of 6 CR Basics and FAQ Overview Computed Radiography is a term used to describe a system that electronically records a radiographic image. Computed Radiographic systems use unique image receptors

More information

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices Moving from film to digital: A study of digital x-ray benefits, challenges and best practices H.U. Pöhler 1 and N. D Ademo 2 DÜRR NDT GmbH & Co. KG, Höpfigheimer Straße 22, Bietigheim-Bissingen, 74321,

More information

The Battle of Carbon Steel

The Battle of Carbon Steel More info ab The Battle of Carbon Steel Advantages of Eddy Current Array over Magnetic Particle and Penetrant Testing for Inspecting the Surface of Carbon Steel Welds Terence Burke Product Application

More information

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto

X-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto X-ray Imaging PHYS Lecture Carlos Vinhais Departamento de Física Instituto Superior de Engenharia do Porto cav@isep.ipp.pt Overview Projection Radiography Anode Angle Focal Spot Magnification Blurring

More information

Introduction To NDT. BY: Omid HEIDARY

Introduction To NDT. BY: Omid HEIDARY Introduction To NDT BY: Omid HEIDARY NDT Methods Penetrant Testing Magnetic Particle Testing Eddy Current Testing Ultrasonic Testing Radiographic Testing Acoustic Emission Infrared Testing Visual Testing

More information

Standard Guide for Radiographic Examination 1

Standard Guide for Radiographic Examination 1 Designation: E 94 04 Standard Guide for Radiographic Examination 1 This standard is issued under the fixed designation E 94; the number immediately following the designation indicates the year of original

More information

Standard Test Method for Radiographic Examination of Metallic Castings 1

Standard Test Method for Radiographic Examination of Metallic Castings 1 Designation: E 1030 00 An American National Standard Standard Test Method for Radiographic Examination of Metallic Castings 1 This standard is issued under the fixed designation E 1030; the number immediately

More information

COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY

COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY COMPARATIVE STUDY BETWEEN COMPUTED RADIOGRAPHY AND CONVENTIONAL RADIOGRAPHY MY1204107 Noorhazleena Azaman, Khairul Anuar Mohd Salleh, Sapizah Rahim, Shaharudin Sayuti, Arshad Yassin, Ab. Razak Hamzah Non

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Coatings Research Group, Inc. 125 Pelret

More information

tas&m, INC., 107 Research Drive, Hampton, VA 23666

tas&m, INC., 107 Research Drive, Hampton, VA 23666 lmaging FLAWS IN THIN METAL PLATES USING A MAGNETO-OPTIC DEVICE B. WinCheSkit, D.R. Prabhut, M. Namkung and E.A. Birtt NASA Langley Research Center Hampton, Virginia 23665 tas&m, INC., 107 Research Drive,

More information

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING

SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT. Exam Content Specifications 8/22/2012 RADT 3463 COMPUTERIZED IMAGING RADT 3463 - COMPUTERIZED IMAGING Section I: Chapter 1 RADT 3463 Computerized Imaging 1 SECTION I - CHAPTER 1 DIGITAL RADIOGRAPHY: AN OVERVIEW OF THE TEXT RADT 3463 COMPUTERIZED IMAGING Section I: Chapter

More information

Non-destructive testing Equipment for eddy current examination Array probe characteristics and verification

Non-destructive testing Equipment for eddy current examination Array probe characteristics and verification Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 20339 First edition 2017-03 Non-destructive testing Equipment for eddy current examination Array probe characteristics and verification Essais

More information

Low Voltage Electron Microscope

Low Voltage Electron Microscope LVEM 25 Low Voltage Electron Microscope fast compact powerful Delong America FAST, COMPACT AND POWERFUL The LVEM 25 offers a high-contrast, high-throughput, and compact solution with nanometer resolutions.

More information

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés

More information

LVEM 25. Low Voltage Electron Mictoscope. fast compact powerful

LVEM 25. Low Voltage Electron Mictoscope. fast compact powerful LVEM 25 Low Voltage Electron Mictoscope fast compact powerful FAST, COMPACT AND POWERFUL The LVEM 25 offers a high-contrast, high-throughput, and compact solution with nanometer resolutions. All the benefits

More information

Standard Guide for Computed Radiology (Photostimulable Luminescence (PSL) Method) 1

Standard Guide for Computed Radiology (Photostimulable Luminescence (PSL) Method) 1 Designation: E 2007 00 Standard Guide for Computed Radiology (Photostimulable Luminescence (PSL) Method) 1 This standard is issued under the fixed designation E 2007; the number immediately following the

More information

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura New Technology https://www.youtube.com/watch?v=ptkzznazb 7U COMPUTED

More information

NON-DESTRUCTIVE EVALUATION SERIES

NON-DESTRUCTIVE EVALUATION SERIES Industrial Radiology NON-DESTRUCTIVE EVALUATION SERIES Non-destructive evaluation now has a central place in modern technology both as a means of evaluating materials and products as they are manufactured

More information

Radiographic Testing (RT) [10]

Radiographic Testing (RT) [10] Radiographic Testing (RT) [10] Definition: An NDT method that utilizes x-rays or gamma radiation to detect discontinuities in materials, and to present their images on recording medium. 1> Electromagnetic

More information

Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010

Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010 REAL TIME X-RAY MICROFOCUS INSPECTION OF HONEYCOMB E. M. Siwek and J. N. Gray Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010 INTRODUCTION Honeycomb structures

More information

Low Voltage Electron Microscope

Low Voltage Electron Microscope LVEM5 Low Voltage Electron Microscope Nanoscale from your benchtop LVEM5 Delong America DELONG INSTRUMENTS COMPACT BUT POWERFUL The LVEM5 is designed to excel across a broad range of applications in material

More information

The HOIS recommended practice for in-service computed radiography of pipes

The HOIS recommended practice for in-service computed radiography of pipes 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa The HOIS recommended practice for in-service computed radiography of pipes Stephen F. BURCH, ESR Technology Ltd 16

More information

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16394 A COMPARATIVE STUDY ON THE PERFORMANCE

More information

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development Teaching Radiographic Technique in a Digital Imaging Paradigm Objectives 1. Discuss the historical development of digital imaging. Dawn Couch Moore, M.M.Sc., RT(R) Assistant Professor and Director Emory

More information

Testing Critical Medical Tubing Using High Frequency Eddy Current Coils

Testing Critical Medical Tubing Using High Frequency Eddy Current Coils Testing Critical Medical Tubing Using High Frequency Eddy Current Coils Troy M Libby Magnetic Analysis Corporation, Mt. Vernon, NY, USA Phone: (914) 699-9450, Fax: (914) 699-9837; e-mail: info@mac-ndt.com

More information

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers More info about this article: http://www.ndt.net/?id=22782 Abstract

More information

Experiences of users in Digital Radiography

Experiences of users in Digital Radiography Computed Radiography Products & Applications Experiences of users in Digital Radiography Jimmy Opdekamp May Jimmy 2006Opdekamp Global Product Manager CR Int l Workshop Imaging NDT Chennai, 25-28 April

More information

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012 The HOIS recommended practice for in-service computed radiography of pipes WCNDT 2012, Durban, SA. April 2012 Dr Stephen F Burch, ESR Technology, Oxfordshire,UK steve.burch@esrtechnology.com ESR Technology

More information

NDE Technology of Pressure Equipment in Line with International Standards

NDE Technology of Pressure Equipment in Line with International Standards 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China NDE Technology of Pressure Equipment in Line with International Standards Part 1:Radiographic Examination Yan LI Jiangsu

More information

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems High-sensitivity optical molecular imaging and high-resolution digital X-ray In-Vivo Imaging Systems In vivo imaging solutions available in several packages Carestream Molecular Imaging offers a selection

More information

Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams 1

Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams 1 Designation: 91 (Reapproved 1996) An American National Standard Standard Test Method for Determining the L/D Ratio of Neutron Radiography Beams 1 This standard is issued under the fixed designation ; the

More information

Nondestructive testing solutions

Nondestructive testing solutions Nondestructive testing solutions Dedicated and proud Magnaflux customers are our most important focus: They drive us to be our best as we follow our mission creating marketleading NDT products and processes.

More information

Gamex Lite 3.0 Program description and operating manual

Gamex Lite 3.0 Program description and operating manual Gamex Lite 3.0 Program description and operating manual Issue No. : 3.0 Date of Issue : 12-2013 Z.U.T. NDT SOFT http://www.ndtsoft.eu Copyright (c) 2013 by Z.U.T. NDT SOFT All Rights Reserved Disclaimer

More information

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. RA202 image production class two Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. What removes excess chemistry from the film prior to it

More information

10/26/2015. Study Harder

10/26/2015. Study Harder This presentation is a professional collaboration of development time prepared by: Rex Christensen Terri Jurkiewicz and Diane Kawamura Study Harder CR detection is inefficient, inferior to film screen

More information

Standard Reference Photographs for Liquid Penetrant Inspection 1

Standard Reference Photographs for Liquid Penetrant Inspection 1 Designation: E433 71 (Reapproved 2008) Standard Reference Photographs for Liquid Penetrant Inspection 1 This standard is issued under the fixed designation E433; the number immediately following the designation

More information

Kodak Thermal Print Microfilms

Kodak Thermal Print Microfilms Kodak Thermal Print Microfilms Kodak Premium 1000 Thermal Print Film 1323 Kodak Thermal Print Film KF 1353/2353 Vesicular films exposed to actinic radiation (UV/violet) generate nitrogen gas within the

More information

Digital Radiography : Flat Panel

Digital Radiography : Flat Panel Digital Radiography : Flat Panel Flat panels performances & operation How does it work? - what is a sensor? - ideal sensor Flat panels limits and solutions - offset calibration - gain calibration - non

More information

international Standard 1106/l

international Standard 1106/l international Standard 1106/l INTERNATIONAL ORGANIZATION FOR STANDARDIZATION~ME~KL(YHAPO~HAR OPI-AHkl3AL&lR ilo CTAHAAPTM3A~klkl.ORGANISATION INTERNATIONALE DE NORMALISATION Recommended practice for radiographic

More information

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over a lifetime Breast cancer screening programs rely on

More information

Digital Imaging Considerations Computed Radiography

Digital Imaging Considerations Computed Radiography Digital Imaging Considerations Digital Radiography Computed Radiography o Cassette based Direct or Indirect Digital Radiography o Cassetteless Computed Radiography 1 CR Image Acquisition Most like conventional

More information

Advancements In Digital Radiography: CR, DR, and DICONDE

Advancements In Digital Radiography: CR, DR, and DICONDE Advancements In Digital Radiography: CR, DR, and DICONDE Leo BOIY and Rick CUSCINO, GE Sensing & Inspection Technologies, Berchem, Belgium and Lewistown, USA Introduction Imaging in today s digital age

More information

Novel Demagnetization Method after Magnetic Particle Testing

Novel Demagnetization Method after Magnetic Particle Testing Novel Demagnetization Method after Magnetic Particle Testing Takuhiko Ito, Arihito Kasahara and Michitaka Hori More info about this article: http://www.ndt.net/?id=22254 Nihon Denji Sokki Co., LTD, 8-59-2

More information

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison Dr. Matthias Purschke/ Ulf Reimer, Agfa NDT Pantak Seifert GmbH und Co. KG, Bogenstr. 4, 96 Ahrensburg,

More information

HANDBOOK ON INDUSTRIAL PROPERTY INFORMATION AND DOCUMENTATION

HANDBOOK ON INDUSTRIAL PROPERTY INFORMATION AND DOCUMENTATION Ref.: Archives NOTICE: This file contains information that was previously published in the page: 3.7.5.0 WIPO Handbook on Industrial Property Information and Documentation, but that has become outdated.

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 12096 First edition 1996-05-01 Submerged arc-welded steel tubes for pressure purposes - Radiographit testing of the weld seam for the detection of imperfections Tubes en acier

More information

Exercise 7. Inductive Proximity Switches EXERCISE OBJECTIVE

Exercise 7. Inductive Proximity Switches EXERCISE OBJECTIVE Exercise 7 Inductive Proximity Switches EXERCISE OBJECTIVE In this exercise, you will be introduced to inductive proximity switches; You will learn how and when they are used; You will also learn their

More information

Transformers 1 of 25 Boardworks Ltd 2016

Transformers 1 of 25 Boardworks Ltd 2016 Transformers 1 of 25 Boardworks Ltd 2016 Transformers 2 of 25 Boardworks Ltd 2016 Linking circuits with magnetism 3 of 25 Boardworks Ltd 2016 Transformers 4 of 25 Boardworks Ltd 2016 Power can be transferred

More information

EDDY CURRENT TESTING

EDDY CURRENT TESTING NEW SOUTH WALES TECHNICAL AND FURTHER EDUCATION COMMISSION EDDY CURRENT TESTING NSW Module Number: Implementation Date: 6161C 01-Jan-1998 National Module Code: EA605 MANUFACTURING AND ENGINEERING MECHANICAL

More information

Luminescence of Nature Press Jason P. Odell, Ph.D.

Luminescence of Nature Press  Jason P. Odell, Ph.D. Luminescence of Nature Press Jason P. Odell, Ph.D. This page left blank to facilitate double-sided printing Title Page Mastering Luminosity Masks A Photoshop User s Guide First Edition 2016 Published in

More information

Eddy Current Array for Aerospace

Eddy Current Array for Aerospace NANDT Conference 2017 Eddy Current Array for Aerospace Presented by Richard Nowak Olympus Product Manager NDT Material provided by Ghislain Morais, OSSA Eddy Current Array ECA Instrument OmniScan ECA:

More information

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image Introduction Chapter 16 Diagnostic Radiology Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther In diagnostic radiology

More information

NAVSEA Requirements for Computed Radiography DRAFT

NAVSEA Requirements for Computed Radiography DRAFT NAVSEA Requirements for Computed Radiography DRAFT 4-17-2015 1. SCOPE This document provides requirements for using filmless digital computed radiography (CR) as an alternative to film radiography when

More information

Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components

Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components Andre Lamarre - OlympusNDT-Quebec City Canada Benoit Lepage - OlympusNDT-Quebec City-Canada Tommy Bourgelas - OlympusNDT-Quebec

More information

Examination of Pipe Welds by Image Plate Based Computed Radiography System

Examination of Pipe Welds by Image Plate Based Computed Radiography System Examination of Pipe Welds by Image Plate Based Computed Radiography System Sanjoy Das, M.S.Rana, Benny Sebastian, D. Mukherjee and K.K. Abdulla Atomic Fuels Division Bhabha Atomic Research Centre Mumbai

More information

JEFFERSON COLLEGE. Radiographic Exposures

JEFFERSON COLLEGE. Radiographic Exposures JEFFERSON COLLEGE COURSE SYLLABUS RAD140 Radiographic Exposures 3 Credit Hours Revised by: Janet E. Akers BS RT (R)(M) Date: September 30, 2013 Kenny Wilson, Director, Health Occupation Programs Dena McCaffrey,

More information

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging Medical Imaging X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging From: Physics for the IB Diploma Coursebook 6th Edition by Tsokos, Hoeben and Headlee And Higher Level Physics 2 nd Edition

More information

Detecting 1 st and 2 nd Layer Simulated Cracks in Aircraft Wing Spanwise Splice Standards Using Remote-Field Eddy Current Technique

Detecting 1 st and 2 nd Layer Simulated Cracks in Aircraft Wing Spanwise Splice Standards Using Remote-Field Eddy Current Technique Detecting 1 st and Layer imulated Cracks in Aircraft Wing panwise plice tandards Using Remote-Field Eddy Current Technique Yushi un, Tianhe Ouyang Innovative Materials Testing Technologies, Inc. 251 N.

More information

Detecting Stress Corrosion Cracking with Eddy Current Array Technology Cracking

Detecting Stress Corrosion Cracking with Eddy Current Array Technology Cracking Detecting Stress Corrosion Cracking with Eddy Current Array Technology Cracking Emilie Peloquin, : emilie.peloquin@olympus ossa.com Advanced Technical Support Team Lead Americas Olympus Scientific Solutions

More information

AA&S Conference 2018 Eddy Current Array for Aircraft

AA&S Conference 2018 Eddy Current Array for Aircraft AA&S Conference 2018 Eddy Current Array for Aircraft Presented by Graham Maxwell Olympus Australia NDT Key Account Manager Material provided by Ghislain Morais Olympus NDT Canada Eddy Current Array ECA

More information

CARESTREAM INDUSTREX Digital Imaging Plates

CARESTREAM INDUSTREX Digital Imaging Plates 2016-09-29 TI-2632 CARESTREAM INDUSTREX Digital Imaging Plates CARESTREAM INDUSTREX Flex Digital Imaging Plates (IPs) are designed for computed radiography in nondestructive testing applications. These

More information

Safelight Fog does what to contrast and density on film?

Safelight Fog does what to contrast and density on film? Terri Jurkiewicz Safelight Fog does what to contrast and density on film? ANSWER INCREASES DENSITY DECREASES CONTRAST Explain how you determine if the focal spot size is within appropriate limits.

More information

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II

RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II RAD 150 RADIOLOGIC EXPOSURE TECHNIQUE II APPROVED 12/O2/2011 EFFECTIVE SPRING 2013-14 Prefix & Number RAD 150 Course Title: Radiologic Exposure Technique II & Lab Purpose of this submission: New Change/Updated

More information

DIGITAL IMAGING Recognise the importance of quality assurance

DIGITAL IMAGING Recognise the importance of quality assurance DIGITAL IMAGING Recognise the importance of quality assurance There are two types of digital image receptor both of which capture a two dimensional image of the three dimensional patient. These are Computed

More information

Acquisition, Processing and Display

Acquisition, Processing and Display Acquisition, Processing and Display Terri L. Fauber, R.T. (R)(M) Department of Radiation Sciences School of Allied Health Professions Virginia Commonwealth University Topics Image Characteristics Image

More information

Digital Photogrammetry. Presented by: Dr. Hamid Ebadi

Digital Photogrammetry. Presented by: Dr. Hamid Ebadi Digital Photogrammetry Presented by: Dr. Hamid Ebadi Background First Generation Analog Photogrammetry Analytical Photogrammetry Digital Photogrammetry Photogrammetric Generations 2000 digital photogrammetry

More information

Pre Conference Workshop on Advanced Digital imaging

Pre Conference Workshop on Advanced Digital imaging Pre Conference Workshop on Advanced Digital imaging Uwe Zscherpel, uwez@bam.de BAM Federal Institute for Materials Research and Testing, Division 8.3 Radiological Methods, Berlin, Germany 1 Content: 1.

More information

High resolution crack detection on turbine blade roots by the use of eddy current and ultrasonic Rayleigh waves

High resolution crack detection on turbine blade roots by the use of eddy current and ultrasonic Rayleigh waves 19 th World Conference on Non-Destructive Testing 2016 High resolution crack detection on turbine blade roots by the use of eddy current and ultrasonic Rayleigh waves Ernst RAU 1, Joachim BAMBERG 2, Jürgen

More information

FLUORESCENCE MAGNETIC PARTICLE FLAW DETECTING SYSTEM BASED ON LOW LIGHT LEVEL CCD

FLUORESCENCE MAGNETIC PARTICLE FLAW DETECTING SYSTEM BASED ON LOW LIGHT LEVEL CCD FLUORESCENCE MAGNETIC PARTICLE FLAW DETECTING SYSTEM BASED ON LOW LIGHT LEVEL CCD Jingrong Zhao 1, Yang Mi 2, Ke Wang 1, Yukuan Ma 1 and Jingqiu Yang 3 1 College of Communication Engineering, Jilin University,

More information

ISO 5-3 INTERNATIONAL STANDARD. Photography and graphic technology Density measurements Part 3: Spectral conditions

ISO 5-3 INTERNATIONAL STANDARD. Photography and graphic technology Density measurements Part 3: Spectral conditions INTERNATIONAL STANDARD ISO 5-3 Third edition 2009-12-01 Photography and graphic technology Density measurements Part 3: Spectral conditions Photographie et technologie graphique Mesurages de la densité

More information

Ray Detection Digital Image Quality and Influential Factors

Ray Detection Digital Image Quality and Influential Factors 7th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Ray Detection Digital Image Quality and Influential Factors Xiangzhao ZENG (Qingyuan, Guangdong, China Guangdong Yingquan

More information

Overview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging

Overview. Professor Roentgen was a Physicist!!! The Physics of Radiation Oncology X-ray Imaging The Physics of Radiation Oncology X-ray Imaging Charles E. Willis, Ph.D. DABR Associate Professor Department of Imaging Physics The University of Texas M.D. Anderson Cancer Center Houston, Texas Overview

More information

Scanning Electron Microscopy

Scanning Electron Microscopy Scanning Electron Microscopy For the semiconductor industry A tutorial Titel Vorname Nachname Titel Jobtitle, Bereich/Abteilung Overview Scanning Electron microscopy Scanning Electron Microscopy (SEM)

More information

Digital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality

Digital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality Digital radiography: Digital radiography is set to become the most common form of processing radiographic images in the next 10 years. This is due to a number of practical and image quality issues. Practical

More information

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY Series 4 CR Fujifilm, the absolute pioneer in digitized medical X-ray imaging advanced into the industrial inspection field

More information