Status of Low-Background Infrared Calibration Facility at NIST
|
|
- Jared Blair
- 5 years ago
- Views:
Transcription
1 Status of Low-Background Infrared Calibration Facility at NIST Simon G. Kaplan #, Solomon I. Woods #, Julia Scherschligt #, Joseph P. Rice #, Adriaan C. Carter *, and Timothy M. Jung * # National Institute of Standards and Technology * Jung Research and Development 1 Calcon August 11, 2014
2 Outline Introduction to Low Background Infrared (LBIR) facility IR test chamber calibrations with NIST Missile Defense Transfer Radiometer (MDXR) Brief functional mode and calibration review Results from calibration of user chambers over 5 years New IR sensor development pw ACR, Si:As BIB trap detector, carbon nanotube ACR New IR source development fluid bath blackbody Conclusions 2
3 NIST radiometric calibration support for missile defense ground test facilities Radiometric calibration of infrared seekers on missile kill vehicles (KVs) is essential to ensure that the devices have the required sensitivity, spectral discrimination, and reliability to perform their mission The KV manufacturers and others maintain a suite of lowbackground vacuum infrared test chambers for radiometric and spectral calibration of the sensors, as well as hardware-in-the-loop testing of discrimination/tracking performance 3 Since the 1990 s, the NIST LBIR facility has provided calibration support for these test chambers: - traceability to national primary standard for infrared power - characterization of chamber performance, e.g., polarization, wavelength calibration, filter transmittance, etc.
4 NIST radiometric calibration support for missile defense ground test facilities Spiral development program for missile defense results in continually more demanding uncertainty requirements for radiometric calibration and sensor spectral discrimination capability The LBIR facility continues to improve its primary scale for lower infrared irradiance levels and methods for transferring the scale to its customers Current LBIR missile defense customers: Raytheon Missile Systems, Tucson, AZ (AB, GMD) Arnold Engineering Development Center, Tullahoma, TN (GMD) Johns Hopkins Applied Physics Laboratory, Laurel, MD (AB) 4
5 Low-Background Infrared Facility (LBIR) On-site characterization of Raytheon EKV test chamber Calibration of EKV blackbody in LBIR facility 5 LBIR facility located at NIST Gaithersburg, MD Range of Test Parameters Blackbody calibrations with absolute cryogenic radiometer (ACR) 1nW W power range Uncertainty currently 1 sigma 100mK On-site measurements with portable transfer radiometer - BXR since 2001; MDXR 2009 Irradiance levels: to 10-9 watts/cm 2 Spectral range 2-30 m with filters, FTS
6 Low-background IR test chambers calibration considerations Mirror Collimated Infrared Beam (used for sensor calibration and testing) Sensor Mirror Reflected throughput Effective focal length Diffraction Aberrations Adsorbed gases Scattering Stray light Other Possible Optics Transmittance or reflectance Alignment, vignetting Polarization Blackbody Infrared Source Assembly Cavity temperature, T Emissivity e(l,t) Aperture area, A Filter transmittance, t Emission from aperture, chopper, filter 6 Cryogenic vacuum chamber
7 7 Capability BXR ( ) MDXR (2009-present) spectral definition filter-based 2-14 um Si:As BIB detector entrance aperture 7 cm diameter 7 cm diameter Fourier transform spectrometer (FTS) and filters 3-30 um Si:As BIB detector stability assessment Limited ACR and blackbody (200 K to 400 K) polarization capability rotatable linear polarizer rotatable and fixed linear polarizers calibration modes irradiance, polarimeter irradiance, radiance, polarimeter, FTS, absolute power radiometer base 20 K 20 K temperature detector base temperature 9 K 2 K radiometric uncertainty (k=1) NIST LBIR transfer radiometers 3.5 % filter radiometer (FR) 2.5 % FTS 1.3 % ACR > 0.5 % noise floor 3 x10-16 W/cm 2 / m FR 1.5x10-16 W/cm 2 / m FTS 1.3x10-13 W/cm 2 / m in a 4 cm -1 spectral interval ACR 3.0x10-12 W/cm 2
8 8 MDXR attached to LBIR 10 centimeter collimator chamber
9 MDXR beam path detector side BIB detector(s) Tertiary paraboloid Filter wheels (spectral and polarization) Translating periscope ACR Cryo-FTS 3-axis stage Secondary paraboloid Variable field stop wheel 9
10 MDXR filter mode calibration factors The MDXR filter mode calibration is done on a band by band basis by viewing the 10CC output with both the FR and ACR. The filter set by which the MDXR is calibrated is the exact same set that is used to calibrate the customer s IR test chambers. The horizontal extent of the lines represent the approximate spectral width of the filter bands used for calibration activities. 10
11 Radiometric calibration of cryogenic FTS mode Using irradiance from internal MDXR blackbody viewed with internal 7 cm collimator Primary paraboloid Collimator Blackbody source 1.0 mm aperture K Defining aperture (7 cm dia) 11 External source SRF ( ) S Planck S ( ) Internal source (with collimator) measured geom ( ) C R Diff mirror ( ) 2
12 Measured/Model Measured/Model Comparison of FTS and FR measurements of user chambers Compare FR to CFTS Roxanne Ap 14 Feb ISSCAT-1 TSM2 Aperture 7 April K 400 K 500 K 600 K 800 K K 340 K 400 K 500 K Wavelength (um) Wavelength (um) 12 FTS and FR results agree within combined (k=1) uncertainties
13 Measured/Model MDXR results for various chambers over 5 years 1.2 MDXR FR measurements user source temperature = 400 K Wavelength ( m) 13 Majority of measurements fall within ± 5 % of the chamber model predicted spectral irradiance
14 MDXR results for one chamber over three years Majority of measurements fall within ± 1 % over successive years of measurements on same (unchanged) chamber. ACR results show < 0.2 % change 14
15 FTS diagnostic results for IR source assemblies Effect of filter heating with source at 800 K Effect of aperture heating with source at 800 K Apparent contribution of emission from filter heating at long wavelength Successive spectra at 10 sec intervals after opening shutter => aperture heated to 135 K (22 um peak) within several minutes 15
16 New sensors being developed for infrared power primary scale realization pw ACR Si:As BIB Trap Detector Carbon nanotube radiometer - Reduced receiver size and improved thermometry - Goal ~10 fw noise floor - RF shielded, 2 K - Compare to pw ACR primary scale from 2 m to 30 m - Transfer to other radiometers - High speed ACR (~ 1 khz) - Range of possible uses - preceding talk by Solomon Woods et al. 16
17 Temperature Controlled Fluid Bath Large Aperture Fluid Bath Blackbody 200 K to 400 K 12 cm Entrance Aperture 60 cm Deep Cavity Expected benefits from Water Bath Blackbody Radiance calibration capability for BXR and MDXR Validate methodology used for the calibration of blackbodies by the ACR Available for loan to LBIR User community for on-site calibration activities All parts fabricated; assembly and testing underway Measurements of cavity emissivity using NIST CHILR facility show e = at 10.6 m and e = at 4 m (see poster by Zinan Jeng et al.) 17
18 Conclusions and future work MDXR has been successfully deployed to calibrate users cryogenic vacuum infrared test chambers since 2009 Demonstrated ability to track chamber radiometric performance within 1 % and provide spectral characterization with 1 cm -1 resolution New absolute sensors being developed for direct traceability to watt at lower power levels or in wider application range New fluid bath blackbody for end-to-end testing of LBIR blackbody calibrations being tested Planning underway with user community for NIST support/development of user-owned radiometers for chamber calibrations 18
Measurements of Infrared Sources with the Missile Defense Transfer Radiometer
Measurements of Infrared Sources with the Missile Defense Transfer Radiometer Simon G. Kaplan #, Solomon I. Woods #, Adriaan C. Carter, and Timothy M. Jung * # National Institute of Standards and Technology
More informationLBIR Fluid Bath Blackbody for Cryogenic Vacuum Calibrations
LBIR Fluid Bath Blackbody for Cryogenic Vacuum Calibrations Timothy M. Jung*, Adriaan C. Carter*, Dale R. Sears*, Solomon I. Woods #, Dana R. Defibaugh #, Simon G. Kaplan #, Jinan Zeng * Jung Research
More informationPart 1: New spectral stuff going on at NIST. Part 2: TSI Traceability of TRF to NIST
Part 1: New spectral stuff going on at NIST SIRCUS-type stuff (tunable lasers) now migrating to LASP Absolute Spectrally-Tunable Detector-Based Source Spectrally-programmable source calibrated via NIST
More informationCapabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments
Capabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments Steve Brown National Institute of Standards & Technology Gaithersburg, MD steve.brown@nist.gov; 301.975.5167 Answer: Ask LASP folks
More informationCarbon Nanotube Radiometer for Cryogenic Calibrations
Carbon Nanotube Radiometer for Cryogenic Calibrations Solomon I. Woods a, Julia K. Scherschligt a, Nathan A. Tomlin b, John H. Lehman b a National Institute of Standards and Technology, 100 Bureau Drive,
More informationCurrent and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains
Measurement Science and Standards (MSS) Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains Arnold A. Gaertner Photometry, Radiometry and Thermometry (PRT) CORM 30
More informationCU-LASP Test Facilities! and Instrument Calibration Capabilities"
CU-LASP Test Facilities! and Instrument Calibration Capabilities" Ginger Drake Calibration Group Manager 303-492-5899 Ginger.Drake@lasp.colorado.edu Thermal Vacuum Test Facilities" 2 Multiple Optical Beam
More informationCCT/10-13 MeP-K direct methods. Section 3.2: Absolute (spectral-band) radiometry (radiation thermometry)
CCT/10-13 MeP-K direct methods Section 3.2: Absolute (spectral-band) radiometry (radiation thermometry) Authors: Graham Machin (NPL, chair), Klaus Anhalt (PTB), Pieter Bloembergen (NIM, formerly NMIJ &
More informationIrradiance Calibration Using a Cryogenic Radiometer and a Broadband Light Source
Irradiance Calibration Using a Cryogenic Radiometer and a Broadband Light Source Jeff Morrill (1), Donald McMullin (2), Linton Floyd (3), Steven Lorentz (4), and Clarence Korendyke (1) (1) Naval Research
More informationPulsed Laser Power Measurement Systems
Pulsed Laser Power Measurement Systems Accurate, reproducible method of determining total laser and laser diode power Ideal for Beam Power Measurement Labsphere s Pulsed Laser Power Measurement Systems
More informationLegacy of NOAA, NASA and NIST Cooperation in Developing Radiometric Calibration Standards Equipment and Methodologies. Raju Datla, Michael Weinreb
Legacy of NOAA, NASA and NIST Cooperation in Developing Radiometric Calibration Standards Equipment and Methodologies CALCON 2012 Conference August 28, 2012 Raju Datla, Michael Weinreb Riverside Technology,
More informationNIST Agency Report May 2012 OUTLINE. The case for traceability NMI capabilities A view to the future the HIP Current/recent NIST activities
NIST Agency Report May 2012 OUTLINE The case for traceability NMI capabilities A view to the future the HIP Current/recent NIST activities The case for traceability Earth Radiation Budget: Solar irradiance
More informationJam Lab Capabilities. Charles Dionne. Matthew Pilat. Jam Lab Manager
Jam Lab Capabilities Charles Dionne Jam Lab Manager charles.e.dionne@baesystems.com Matthew Pilat Senior Systems Engineer matthew.pilat@baesystems.com 1 Infrared Countermeasure (IRCM) Jam Lab Capabilities
More informationLASP / University of Colorado
The SORCE SIM Instrument: Progress Toward Spectral Irradiance Time Series Throughout the 300-3000 nm Region. Jerald Harder, Juan Fontenla, Byron Smiley, Sean Davis, George Lawrence and Gary Rottman LASP
More informationChemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES
Chemistry 524--"Hour Exam"--Keiderling Mar. 19, 2013 -- 2-4 pm -- 170 SES Please answer all questions in the answer book provided. Calculators, rulers, pens and pencils permitted. No open books allowed.
More informationCIRiS: Compact Infrared Radiometer in Space August, 2017
1 CIRiS: Compact Infrared Radiometer in Space August, 2017 David Osterman PI, CIRiS Mission Presented by Hansford Cutlip 10/8/201 7 Overview of the CIRiS instrument and mission The CIRiS instrument is
More informationRADIOMETRIC PERFORMANCE OF THE CRIS INSTRUMENT FOR JPSS-1
Place image here (10 x 3.5 ) RADIOMETRIC PERFORMANCE OF THE CRIS INSTRUMENT FOR JPSS-1 RONALD GLUMB, LAWRENCE SUWINSKI, STEVEN WELLS, REBECCA MALLOY CALCON Technical Conference Logan, UT August 22-25,
More informationNIRCam optical calibration sources
NIRCam optical calibration sources Stephen F. Somerstein, Glen D. Truong Lockheed Martin Advanced Technology Center, D/ABDS, B/201 3251 Hanover St., Palo Alto, CA 94304-1187 ABSTRACT The Near Infrared
More informationRadiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,
SORCE Science Meeting 29 January 2014 Mark Rast Laboratory for Atmospheric and Space Physics University of Colorado, Boulder Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,
More informationNIST EUVL Metrology Programs
NIST EUVL Metrology Programs S.Grantham, C. Tarrio, R.E. Vest, Y. Barad, S. Kulin, K. Liu and T.B. Lucatorto National Institute of Standards and Technology (NIST) Gaithersburg, MD USA L. Klebanoff and
More informationSpectroradiometer characterisations for traceable solar radiation measurements
Spectroradiometer characterisations for traceable solar radiation measurements Julian Gröbner, Natalia Kouremeti, Stelios Kazadzis, Gregor Hülsen, Luca Egli Physikalisch-Meteorologisches Observatorium
More informationACRIM3 Characterization by the LASP/TRF and the Total Solar Irradiance Database
ACRIM3 Characterization by the LASP/TRF and the Total Solar Irradiance Database ACRIM3 SCIENCE TEAM Dr. Richard C. Willson ACRIM Principal Investigator ACRIMSAT PROJECT Sandy Kwan JPL Project Manager Dr.
More informationIntercomparison of radiation temperature measurements over the temperature range from 1600 K to 3300 K
INSTITUTE OF PHYSICS PUBLISHING Metrologia 40 (2003) S39 S44 METROLOGIA PII: S0026-1394(03)56056-X Intercomparison of radiation temperature measurements over the temperature range from 1600 K to 3300 K
More informationObservational Astronomy
Observational Astronomy Instruments The telescope- instruments combination forms a tightly coupled system: Telescope = collecting photons and forming an image Instruments = registering and analyzing the
More informationNew automated laser facility for detector calibrations
CORM annual conference, NRC, Ottawa, CANADA June 1, 2012 New automated laser facility for detector calibrations Yuqin Zong National Institute of Standards and Technology Gaithersburg, Maryland USA Overview
More informationAdvances in Measuring UV LED Arrays
Advances in Measuring UV LED Arrays Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets May 8, 2018 Measurement Expectations Temperature Industrial thermometry: 1% accuracy Laboratory thermometry:
More informationRADIATION BUDGET INSTRUMENT (RBI): FINAL DESIGN AND INITIAL EDU TEST RESULTS
Place image here (10 x 3.5 ) RADIATION BUDGET INSTRUMENT (RBI): FINAL DESIGN AND INITIAL EDU TEST RESULTS RONALD GLUMB, JAY OVERBECK, CHRISTOPHER LIETZKE, JOHN FORSYTHE, ALAN BELL, AND JASON MILLER NON-EXPORT
More informationCross Track Infrared Sounder (CrIS) Flight Model 1 Test Results
May 6, 2009 Ronald Glumb, Joseph P. Predina, Robert Hookman, Chris Ellsworth, John Bobilya, Steve Wells, Lawrence Suwinski, Rebecca Frain, and Larry Crawford For Publication at the ASS-FTS14 Conference
More informationDIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS
DIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS Stephen E. Maxwell, Sensor Science Division, PML Kevin O. Douglass, David F. Plusquellic, Radiation and Biomolecular Physics Division, PML
More informationThe TSIS Spectral Irradiance Monitor: Prism Optical Degradation Studies
The TSIS Spectral Irradiance Monitor: Prism Optical Degradation Studies Lo Erik Richard, Dave Harber, Joel Rutkowski, Matt Triplett, Kasandra O Malia Laboratory for Atmospheric and Space Physics (LASP)
More informationIntegrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold
1354 MINIS Oriel Integrating Spheres Integrating spheres are ideal optical diffusers; they are used for radiometric measurements where uniform illumination or angular collection is essential, for reflectance
More informationDevelopment of HWIL Testing Capabilities for Satellite Target Emulation at AEDC *
Development of HWIL Testing Capabilities for Satellite Target Emulation at AEDC * H. S. Lowry and D. H. Crider Aerospace Testing Alliance, Arnold Engineering Development Center (AEDC) J. T. Staines and
More informationTotal solar irradiance measurements with PREMOS/PICARD
Total solar irradiance measurements with PREMOS/PICARD Werner Schmutz, André Fehlmann, Wolfgang Finsterle, Greg Kopp, and Gerard Thuillier Citation: AIP Conf. Proc. 1531, 624 (2013); doi: 10.1063/1.4804847
More informationUV-VIS-IR Spectral Responsivity Measurement System for Solar Cells
November 1998 NREL/CP-52-25654 UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells H. Field Presented at the National Center for Photovoltaics Program Review Meeting, September 8 11, 1998,
More informationDevelopment of 2 Total Spectral Radiant Flux Standards at NIST
CIE/USA Annual Conference, October 7, 2014, Seattle, WA Development of 2 Total Spectral Radiant Flux Standards at NIST Yuqin Zong National Institute of Standards and Technology Gaithersburg, Maryland Outline
More informationMeasuring the Performance of UV LED Light Sources
Measuring the Performance of UV LED Light Sources Sink or Swim June 5, 2018 Jim Raymont EIT Instrument Markets Measurement Expectations Temperature Industrial thermometry: 1% accuracy Laboratory thermometry:
More informationOPAL Optical Profiling of the Atmospheric Limb
OPAL Optical Profiling of the Atmospheric Limb Alan Marchant Chad Fish Erik Stromberg Charles Swenson Jim Peterson OPAL STEADE Mission Storm Time Energy & Dynamics Explorers NASA Mission of Opportunity
More informationOL Series 426 Low Light Level lntegrating Sphere Calibration Standards
OL Series 426 Low Light Level lntegrating Sphere Calibration Standards GENERAL The OL Series 426 Low-Light-Level Calibration Standard is designed for accurately calibrating very sensitive microphotometers,
More informationThe below identified patent application is available for licensing. Requests for information should be addressed to:
DEPARTMENT OF THE NAVY OFFICE OF COUNSEL NAVAL UNDERSEA WARFARE CENTER DIVISION 1176 HOWELL STREET NEWPORT Rl 0841-1708 IN REPLY REFER TO Attorney Docket No. 300048 7 February 017 The below identified
More informationThe Importance of Total Measured Optic Response in UV LED Measurement. Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets
The Importance of Total Measured Optic Response in UV LED Measurement Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets October 18, 2017 Measurement Expectations Temperature Industrial thermometry:
More informationApplication Note (A16)
Application Note (A16) Eliminating LED Measurement Errors Revision: A December 2001 Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1 407 422 3171 Fax: 1 407 648 5412 Email: sales@goochandhousego.com
More informationDevelopment of four-dimensional imaging spectrometers (4D-IS)
Development of four-dimensional imaging spectrometers (4D-IS) Nahum Gat, Gordon Scriven, John Garman, Ming De Li, Jingyi Zhang Opto-Knowledge Systems, Inc. (OKSI) ABSTRACT The incentive for the 4D-IS concept
More informationFundamentals of Infrared Detector Operation and Testing
Fundamentals of Infrared Detector Operation and Testing JOHN DAVID VINCENT Santa Barbara Research Center Goleta, California WILEY A Wiley-Interscience Publication John Wiley & Sons New York I Chichester
More informationBlackbody Radiation Calibration Sources From -20 C to 3000 C traceable to NIST
Blackbody Radiation Calibration Sources From -20 C to 3000 C traceable to NIST Mikron Blackbody Radiation Calibration Sources Mikron has been designing and building blackbody calibration sources since
More information12 GeV Upgrade Project DESIGN SOLUTIONS DOCUMENT. Upgrade Hall A
12 GeV Upgrade Project DESIGN SOLUTIONS DOCUMENT Upgrade Hall A Version 1.2 July 28, 2010 DESIGN SOLUTIONS DOCUMENT Upgrade Hall A APPROVALS Approved by: 12 GeV Upgrade Control Account Manager, Hall A
More informationResults of J1 VIIRS testing using NIST s Traveling SIRCUS
Results of J1 VIIRS testing using NIST s Traveling SIRCUS Steven W. Brown and Keith R. Lykke, NIST, Gaithersburg, MD Joel McCorkel, Brendan McAndrew, Gene Waluschka, and Jeff McIntire (Sigma Space), NASA
More informationNASTER System Definition Proposal
Remote Sensing Team NASTER System Definition Proposal All rights reserved. - 7/14/03 Page 1 Overview Review and comment the mid-ir requirements Presentation of ABB s current platform technology Proposed
More informationKazuhiro TANAKA GCOM project team/jaxa April, 2016
Kazuhiro TANAKA GCOM project team/jaxa April, 216 @ SPIE Asia-Pacific 216 at New Dehli, India 1 http://suzaku.eorc.jaxa.jp/gcom_c/index_j.html GCOM mission and satellites SGLI specification and IRS overview
More informationImproving the Collection Efficiency of Raman Scattering
PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution
More informationRadiometric Measurement Traceability Paths for Photovoltaic Calibrations. Howard W. Yoon Physical Measurement Laboratory NIST
Radiometric Measurement Traceability Paths for Photovoltaic Calibrations Howard W. Yoon Physical Measurement Laboratory NIST Solar energy and PV Solar radiation: free and abundant! Photovoltaics (PV):
More informationHigh Accuracy IR Radiances-CLARREO Slide 1
High Accuracy IR Radiances for Weather & Climate Part 2: Airborne validation of IASI and AIRS (JAIVEx) & the role for future benchmark satellites (CLARREO) Henry E. Revercomb, David C. Tobin, Fred A. Best,
More informationRADIOMETRIC AND PHOTOMETRIC MEASUREMENTS AT THE LNE-INM/CNAM
RADIOMETRIC AND PHOTOMETRIC MEASUREMENTS AT THE LNE-INM/CNAM Jean Bastie, Laura Patricia Gonzalez Galvan. Institut National de Métrologie Conservatoire National des Arts et Métiers 61 rue du Landy 93210
More informationTSBB09 Image Sensors 2018-HT2. Image Formation Part 1
TSBB09 Image Sensors 2018-HT2 Image Formation Part 1 Basic physics Electromagnetic radiation consists of electromagnetic waves With energy That propagate through space The waves consist of transversal
More informationAMIPAS. Advanced Michelson Interferometer for Passive Atmosphere Sounding. Concepts and Technology for Future Atmospheric Chemistry Sensors
Earth Observation, Navigation & Science Concepts and Technology for Future Atmospheric Chemistry Sensors AMIPAS Advanced Michelson Interferometer for Passive Atmosphere Sounding Markus Melf, Winfried Posselt,
More informationSR-5000N design: spectroradiometer's new performance improvements in FOV response uniformity (flatness) scan speed and other important features
SR-5000N design: spectroradiometer's new performance improvements in FOV response uniformity (flatness) scan speed and other important features Dario Cabib *, Shmuel Shapira, Moshe Lavi, Amir Gil and Uri
More informationFull Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions
Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions Combining the Expertise of Two Industry Leaders to Give You An Immense Range of Complete Electro-Optical
More informationDepartment of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77. Table of Contents 1
Efficient single photon detection from 500 nm to 5 μm wavelength: Supporting Information F. Marsili 1, F. Bellei 1, F. Najafi 1, A. E. Dane 1, E. A. Dauler 2, R. J. Molnar 2, K. K. Berggren 1* 1 Department
More information1/8 m GRATING MONOCHROMATOR
1/8 m GRATING GRATING OUTPUT PORT INPUT PORT 77250 1/8 m Monochromator with 6025 Hg(Ar) Spectral Calibration Lamp. Low cost, compact size and high performance, ideal for OEM applications Very efficient
More informationDevelopment of C-Mod FIR Polarimeter*
Development of C-Mod FIR Polarimeter* P.XU, J.H.IRBY, J.BOSCO, A.KANOJIA, R.LECCACORVI, E.MARMAR, P.MICHAEL, R.MURRAY, R.VIEIRA, S.WOLFE (MIT) D.L.BROWER, W.X.DING (UCLA) D.K.MANSFIELD (PPPL) *Supported
More informationDevelopment of Chinese SI-traceable reference instruments and retrospective recalibration of historical satellite data
GRWG Web Meeting Topic: Planning a GSICS/CEOS-WGCV Workshop on SI-traceable reference instruments Development of Chinese SI-traceable reference instruments and retrospective recalibration of historical
More informationBig League Cryogenics and Vacuum The LHC at CERN
Big League Cryogenics and Vacuum The LHC at CERN A typical astronomical instrument must maintain about one cubic meter at a pressure of
More informationUnique Scattering Measurements Using the Agilent Universal Measurement Accessory (UMA)
Click to edit Master title style Unique Scattering Measurements Using the Agilent Universal Measurement Accessory (UMA) mark.fisher@agilent.com Click to edit Master title style Rapid, Automated, Quality
More informationCompact Dual Field-of-View Telescope for Small Satellite Payloads
Compact Dual Field-of-View Telescope for Small Satellite Payloads James C. Peterson Space Dynamics Laboratory 1695 North Research Park Way, North Logan, UT 84341; 435-797-4624 Jim.Peterson@sdl.usu.edu
More informationAnti-reflection Coatings
Spectral Dispersion Spectral resolution defined as R = Low 10-100 Medium 100-1000s High 1000s+ Broadband filters have resolutions of a few (e.g. J-band corresponds to R=4). Anti-reflection Coatings Significant
More informationHistorical. McPherson 15 Mount
McPherson 15 Mount Normal incidence designs include the McPherson 15 (classical 1.0 meter focal length) and modern NIM units. The latter features smaller included angles, longer focal lengths (e.g. 3,
More informationThe designs for a high resolution Czerny-Turner spectrometer are presented. The results of optical
ARTICLE High Resolution Multi-grating Spectrometer Controlled by an Arduino Karl Haebler, Anson Lau, Jackson Qiu, Michal Bajcsy University of Waterloo, Waterloo, Ontario, Canada Abstract The designs for
More informationCONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application
CONFIGURING Your Spectroscopy System For PEAK PERFORMANCE A guide to selecting the best Spectrometers, s, and s for your application Spectral Measurement System Spectral Measurement System Spectrograph
More informationLINEARPYROMETER LP4. Technical Documentation KE November TN
1 LINEARPYROMETER LP4 Technical Documentation KE 256-6.2007 November 2010 5-TN-1622-100 2 1. General Description With the Linearpyrometer Type LP4 a measuring instrument has been made available for pyrometric
More informationTIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES
TIME-PRESERVING MONOCHROMATORS FOR ULTRASHORT EXTREME-ULTRAVIOLET PULSES Luca Poletto CNR - Institute of Photonics and Nanotechnologies Laboratory for UV and X-Ray Optical Research Padova, Italy e-mail:
More informationOff-Axis Response Measurement of the Sounding of the Atmosphere Using Broadband Emission Radiometry (SABER) Telescope
Utah State University DigitalCommons@USU Space Dynamics Lab Publications Space Dynamics Lab 1-1-2002 Off-Axis Response Measurement of the Sounding of the Atmosphere Using Broadband Emission Radiometry
More informationInfluence of the light spectral distribution used in the radiometers calibration
Influence of the light spectral distribution used in the radiometers calibration J C Moraes and L O Guerra Allergisa Pesquisa Dermato-Cosmética Ltda GRUPO INVESTIGA, 452. Dr. Romeu Tórtima Avenue, Postcode:
More informationSection 1: SPECTRAL PRODUCTS
Section 1: Optical Non-dispersive Wavelength Selection Filter Based Filter Filter Fundamentals Filter at an Incidence Angle Filters and Environmental Conditions Dispersive Instruments Grating and Polychromators
More informationSPECTRORADIOMETRY METHODS: A GUIDE TO PHOTOMETRY AND VISIBLE SPECTRORADIOMETRY
SPECTRORADIOMETRY METHODS: A GUIDE TO PHOTOMETRY AND VISIBLE SPECTRORADIOMETRY Written By William E. Schneider, Richard Young, Ph.D 1. SPECTRORADIOMETRY METHODS 1.1. Spectroradiometrics vs Photometric
More informationHigh Illuminance Calibration Facility and Procedures
Final manuscript for J. IES, 27-2, 132-140 (1998) High Illuminance Calibration Facility and Procedures Yoshi Ohno Optical Technology Division National Institute of Standards and Technology Metrology A320,
More informationOf straying photons, shiny apertures and inconstant solar constants Advances in TSI radiometery
Of straying photons, shiny apertures and inconstant solar constants Advances in TSI radiometery SORCE 2014 Science Meeting, 29 January 2014 Wolfgang Finsterle Physikalisch-Meteorologisches Observatorium
More informationGemini 8m Telescopes Instrument Science Requirements. R. McGonegal Controls Group. January 27, 1996
GEMINI 8-M Telescopes Project Gemini 8m Telescopes Instrument Science Requirements R. McGonegal Controls Group January 27, 1996 GEMINI PROJECT OFFICE 950 N. Cherry Ave. Tucson, Arizona 85719 Phone: (520)
More informationCopyrighted Material. Contents
Preface xiii 1 Introduction 1 1.1 Concepts 1 1.2 Spacecraft Sensors Cost 5 1.2.1 Introduction to Cost Estimating 5 1.2.2 Cost Data 7 1.2.3 Cost Estimating Methodologies 8 1.2.4 The Cost Estimating Relationship
More informationSolar Optical Telescope (SOT)
Solar Optical Telescope (SOT) The Solar-B Solar Optical Telescope (SOT) will be the largest telescope with highest performance ever to observe the sun from space. The telescope itself (the so-called Optical
More informationFully Portable Spectrophotometer for Transmission Measurement
November 2008 LCRT-2005-S Portable Spectrophotometer for Transmission Measurement Spectral Transmission in d/0 and 0/0 Measurement Geometries Transparency Measurement in real in-line Set-up Photometric
More informationSpatially Resolved Backscatter Ceilometer
Spatially Resolved Backscatter Ceilometer Design Team Hiba Fareed, Nicholas Paradiso, Evan Perillo, Michael Tahan Design Advisor Prof. Gregory Kowalski Sponsor, Spectral Sciences Inc. Steve Richstmeier,
More informationISS-30-VA. Product tags: Integrating Sphere Source. https://www.gigahertz-optik.de/en-us/product/iss-30-va. Gigahertz-Optik GmbH 1/5
ISS-30-VA https://www.gigahertz-optik.de/en-us/product/iss-30-va Product tags: Integrating Sphere Source Gigahertz-Optik GmbH 1/5 Description standards for spectral radiance Spectroradiometers and other
More informationDesign of the cryo-optical test of the Planck reflectors
Design of the cryo-optical test of the Planck reflectors S. Roose, A. Cucchiaro & D. de Chambure* Centre Spatial de Liège, Avenue du Pré-Aily, B-4031 Angleur-Liège, Belgium *ESTEC, Planck project, Keplerlaan
More informationInfrared Single Shot Diagnostics for the Longitudinal. Profile of the Electron Bunches at FLASH. Disputation
Infrared Single Shot Diagnostics for the Longitudinal Profile of the Electron Bunches at FLASH Disputation Hossein Delsim-Hashemi Tuesday 22 July 2008 7/23/2008 2/ 35 Introduction m eb c 2 3 2 γ ω = +
More informationΘΘIntegrating closedloop adaptive optics into a femtosecond laser chain
Θ ΘΘIntegrating closedloop adaptive optics into a femtosecond laser chain www.imagine-optic.com The Max Planck Institute of Quantum Optics (MPQ) has developed an Optical Parametric Chirped Pulse Amplification
More informationCollector development with IR suppression and EUVL optics refurbishment at RIT
Collector development with IR suppression and EUVL optics refurbishment at RIT Yuriy Platonov, Michael Kriese, Raymond Crucet, Yang Li, Vladimir Martynov, Licai Jiang, Jim Rodriguez Rigaku Innovative Technologies
More informationTHE MIAMI-2001 RADIOMETER INTERCOMPARISON
ABSTRACT THE MIAMI-2001 RADIOMETER INTERCOMPARISON P. J. Minnett (1), I. J. Barton (2), J. P. Rice (3) (1) Rosenstiel School of Marine and Atmospheric Science, University of Miami, Florida, USA. Email:
More informationFar field intensity distributions of an OMEGA laser beam were measured with
Experimental Investigation of the Far Field on OMEGA with an Annular Apertured Near Field Uyen Tran Advisor: Sean P. Regan Laboratory for Laser Energetics Summer High School Research Program 200 1 Abstract
More informationGuide to SPEX Optical Spectrometer
Guide to SPEX Optical Spectrometer GENERAL DESCRIPTION A spectrometer is a device for analyzing an input light beam into its constituent wavelengths. The SPEX model 1704 spectrometer covers a range from
More informationTECHNICAL NEPORTS FILE COtY AEDC-TR Application of Diffraction Corrections to Blackbody Sources
Application of Diffraction Corrections to Blackbody Sources R. P. Young and C. B. Herron Calspan Corporation/AEDC Operations June 1991 Final Report for Period December 1990- March 1991 TECHNICAL NEPORTS
More informationMaya2000 Pro Spectrometer
now with triggering! Maya2000 Pro Our Maya2000 Pro Spectrometer offers you the perfect solution for applications that demand low light-level, UV-sensitive operation. This back-thinned, 2D FFT-CCD, uncooled
More informationInstruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers
Aalto University School of Electrical Engineering Metrology Research Institute Hans Baumgartner Instruction manual for Version 1.0 24/11/2016 Page 2 (9) 1. Table of contents 1. Table of contents... 2 2.
More informationCalibration of a High Dynamic Range, Low Light Level Visible Source
Calibration of a High Dynamic Range, Low Light Level Visible Source Joe LaVeigne a, Todd Szarlan a, Nate Radtke a a Santa Barbara Infrared, Inc., 30 S. Calle Cesar Chavez, #D, Santa Barbara, CA 93103 ABSTRACT
More informationTHz Components and Systems
THz Components and Systems Serving the global THz community since 1992 Table of Contents Lenses 3 Free-standing wire-grid polarizers.. 5 Mid-IR polarizers.... 7 Quasi-Optical Sources (BWOs)...8 VR-2S BWO
More informationNon-optically Combined Multi-spectral Source for IR, Visible, and Laser Testing
Non-optically Combined Multi-spectral Source for IR, Visible, and Laser Testing Joe LaVeigne a, Brian Rich a, Steve McHugh a, Peter Chua b a Santa Barbara Infrared, Inc., 30 S. Calle Cesar Chavez, #D,
More informationInfra Red Interferometers
Infra Red Interferometers for performance testing of infra-red materials and optical systems Specialist expertise in testing, analysis, design, development and manufacturing for Optical fabrication, Optical
More informationSome of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design)
Lens design Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design) Focal length (f) Field angle or field size F/number
More informationMETimage Calibration & Performance Verification. Xavier Gnata ICSO 2016
METimage Calibration & Performance Verification Xavier Gnata ICSO 2016 METimage factsheet Mission Passive imaging radiometer (multi-spectral) 20 spectral channels (443 13.345nm) Global coverage within
More informationPHONE: +1 (519) FAX: +1 (519)
Version 1.1 Jan 2017 PHONE: +1 (519) 644-0135 FAX: Far-Infrared and terahertz (THz) radiation is the spectral region at the long wavelength end of the infrared and the short end of the microwave region,
More informationTechnology Days GSFC Optics Technologies. Dr. Petar Arsenovic
Technology Days 2011 GSFC Optics Technologies Dr. Petar Arsenovic Optics Capabilities Optical Design and Analysis Opto-mechanical Design and Fabrication Materials and Thin Films Component Development and
More informationAIM payload OPTEL-D. Multi-purpose laser communication system. Presentation to: AIM Industry Days ESTEC, 22nd February 2016
AIM payload OPTEL-D Multi-purpose laser communication system Presentation to: AIM Industry Days ESTEC, 22nd February 2016 Outline 1. Objectives OPTEL-D 2. Technology Development Activities 3. OPTEL-D payload
More information