Part 1: New spectral stuff going on at NIST. Part 2: TSI Traceability of TRF to NIST
|
|
- Sophia Andrews
- 5 years ago
- Views:
Transcription
1 Part 1: New spectral stuff going on at NIST SIRCUS-type stuff (tunable lasers) now migrating to LASP Absolute Spectrally-Tunable Detector-Based Source Spectrally-programmable source calibrated via NIST detector Could replace some lamp-illuminated integrating sphere apps Research at NIST in progress to demonstrate stability and accuracy Hyperspectral Image Projector (HIP) A dispersed supercontinuum white-light laser source is used to simulate spectra at 2 nm resolution. Part 2: TSI Traceability of TRF to NIST Optical Technology Division TSI TRF Calibration against NIST POWR Page 1
2 Absolute Spectrally-Tunable Detector-Based Source Broadband vs Narrowband Operation Steve Brown et al., NIST For more details, see Brown et al., Proc. SPIE 7807, 78070A (2010) Optical Technology Division TSI TRF Calibration against NIST POWR Page 2 2
3 Spectral Radiance (W/m 2 sr um) Spectral Radiance (W/m 2 sr um) HIP simulating Top-of-Atmosphere (TOA) Solar Spectrum Joe Rice, paper in progress Left panel shows the maximum HIP radiance and reflected solar radiance Right panel is an expanded scale: Red shows HIP output matched OLI Matching Absolute_Maximum OLI Matching Absolute Measured to some from HIP typical Prototype VNIR Earth-reflected Spectral Engine 11/3/10 spectra in the Visible-Near IR (VNIR) Measured from HIP Prototype VNIR Spectral Engine 11/3/10 Modeled Spatial Engine: XGA DMD f/3 with 20% Transmittance Modeled Spatial Engine: XGA DMD f/3 with 20% Transmittance HIP VNIR Limits 6000 HIP VNIR Limits TOA Solar Bare Desert Soil 1000 TOA Solar 100 Vegetation Wavelength (nm) Wavelength (nm) Optical Technology Division TSI TRF Calibration against NIST POWR Page 3
4 Comparison of the Total Solar Irradiance Radiometer Facility Cryogenic Radiometer against the NIST Primary Optical Watt Radiometer Joseph P. Rice and Allan W. Smith Optical Technology Division National Institute of Standards and Technology (NIST) Gaithersburg, Maryland Greg A. Kopp, David M. Harber, and Karl F. Heuerman Laboratory for Atmospheric and Space Physics (LASP) University of Colorado Boulder, Colorado Steven R. Lorentz L-1 Standards and Technology New Windsor, Maryland Contact: Optical Technology Division TSI TRF Calibration against NIST POWR Page 4
5 Cryogenic Electrical Substitution Radiometry Thermalized optical laser power is compared to thermalized electrical power in a black cavity Generally, active cavity radiometers in vacuum at 2 K to 5 K Primary standard at NIST and in most other industrialized nations for optical power responsivity of transfer detectors such as Si-diode trap detectors Intercompared internationally via portable transfer detectors at 0.02% (k=2) uncertainty Liquid Nitrogen Liquid He at 2K Primary Optical Watt Radiometer (POWR) Optical Technology Division TSI TRF Calibration against NIST POWR Page 5
6 International Intercomparison of Cryogenic Radiometers Standards labs can measure responsivity of traps to <1 mw laser power to about 0.02% This was in the late 1990 s, and NIST numbers are from HACR (predecessor to POWR). BIPM report: Optical Technology Division TSI TRF Calibration against NIST POWR Page 6
7 10 4 x Difference from the Mean Intercomparison of Present-Day Standard NIST Cryogenic Radiometers POWR 27Apr05 Intercomparis nm 514 nm 633 nm L-1 POWR LOCR Optical Technology Division TSI TRF Calibration against NIST POWR Page 7
8 Introduction to the Intercomparison Reported in This Talk LASP has now developed a facility for pre-flight calibration of TSI Instruments Total Solar Irradiance (TSI) Radiometer Facility (TRF) System-level calibration in irradiance mode at TSI irradiance level (68 mw for TIM) This is the first ever facility capable of this feat at less than 0.1% uncertainty level Motivated by the need for improved TSI measurement accuracy Supported by the NASA Glory Project Used for Glory Total Irradiance Monitor (TIM) The irradiance scale is based upon a new cryogenic radiometer: TRF Radiometer Cryogenic radiometers are in use worldwide and yield the lowest uncertainty Typical uncertainty of order 0.01% (k=1) (=100 ppm), but only at 2 mw power level The TRF Radiometer is optimized for 68 mw power level: first of its kind What is the radiant power scale uncertainty of the TRF Radiometer? 1. Can be determined from the components, as for any active cavity radiometer AND/OR 2. Can be assigned based in large part upon transfer from a NIST cryogenic radiometer, such as the NIST Primary Optical Watt Radiometer (POWR) This talk describes a scale comparison of the TRF Radiometer with the NIST POWR Result: NIST Correction of TRF native scale by +306 ppm with an uncertainty of 98 ppm (k=1) is required to calibrate it on the NIST POWR scale Optical Technology Division TSI TRF Calibration against NIST POWR Page 8
9 Beam From 532 nm Laser Experiment Description Part 1 Align translation stage so that laser beam enters POWR. Adjust ½ wave plate to turn power to 2 mw. Record POWR shuttered power measurements and both Si trap photodiode signals. Beamsplitter 2 Trap Photodiode 2 POWR Brewster Window ½ Wave Plate Shutters Trap Photodiode 1 POWR 2 mw Intensity Stabilizer Spatial Filter Polarizer Beamsplitter 1 TRF Radiometer Brewster Window Translation TRF Stage Radiometer Optical Technology Division TSI TRF Calibration against NIST POWR Page 9
10 Beam From 532 nm Laser Experiment Description Part 2 Move translation stage so that laser beam enters TRF Radiometer. Adjust ½ wave plate to turn power up to 68 mw. Record TRF Radiometer shuttered power measurements and both Si trap photodiode signals. Beamsplitter 2 Trap Photodiode 2 POWR Brewster Window POWR ½ Wave Plate Shutters Trap Photodiode 1 68 mw Translation Stage Intensity Stabilizer Spatial Filter Polarizer Beamsplitter 1 TRF Radiometer Brewster Window TRF Radiometer Optical Technology Division TSI TRF Calibration against NIST POWR Page 10
11 Servo Error (counts) Power (mw) Trap Response (V) Typical Raw Data SciData_REC TRF Shutter Cycles TRF Radiometer 0 TS TRF Shutter Cycle Trap Response Trap 1 Trap Photodiode Signals Heater Power Servo Error Time (s) Trap Time (s) Optical Technology Division TSI TRF Calibration against NIST POWR Page 11
12 Results Shuttered Laser Power Entering TRF Aperture Based only on POWR (i.e. what TRF should measure) P L NP r r P Corrections Trap Photodiode Responsivity (1) Rt Vt ' Trap Photodiode Response (2) Value Uncertainty Value Uncertainty Corrections (June 12, 2008) Component (June 13, 2008) Component R t V t ' mw 43 ppm mw 58 ppm Relative Window Transmittance r ppm ppm Relative Scatter r ppm ppm POWR Nonequivalence N ppm ppm POWR Absorptance ppm ppm POWR Electrical Scale ppm ppm POWR Corrected Value P L mw 90 ppm mw 97 ppm TRF Radiometer Value P TDVM mw 34 ppm mw 23 ppm P L / P TDVM ppm ppm P L / P TDVM Recommended Value Combined Uncertainty (k=1) 98 ppm Optical Technology Division TSI TRF Calibration against NIST POWR Page 12
13 Summary A scale comparison of the NIST POWR and the TRF Radiometer was performed 532 nm Radiant power (underfilled apertures), as opposed to irradiance mode (overfilled apertures) POWR at 2 mw, TRF Radiometer at 68 mw, two trap photodiodes used as transfer The TRF Radiometer shuttered power measurement reads low by the following amount: 306 ppm +/- 98 ppm (k=1) The TRF Radiometer native scale used here had not been explicitly corrected for its nonequivalence, cavity reflectance (about 38 ppm), or electrical power scale calibration Applying the recommended correction above intrinsically corrects for these effects A detailed report on this comparison is being written for a published journal article We thank the NASA Glory Project for supporting this work. Optical Technology Division TSI TRF Calibration against NIST POWR Page 13
14 Motivation: Laboratory sources do not simulate reality Optical imaging and spectral sensors are tested and calibrated with uniform/simple laboratory sources Examples: Lamp-illuminated integrating sphere Blackbody Standard bar or resolution charts But reality is spatially and radiometrically non-uniform and complex Example: AVIRIS image of North Island Naval Air Station, San Diego, CA Optical Technology Division TSI TRF Calibration against NIST POWR Page 14
15 Existing Spectral Radiance Scales Are Based on Lamps Spectroradiometers have not demonstrated the capability that they can maintain a scale at the 0.1% level (yet). Only about 1% (1sigma) at best. Typical results from spectroradiometer measuring lamp-illuminated sphere: Graphic courtesy of NIST s Remote Sensing Laboratory However, unfiltered radiance detectors have demonstrated the potential to hold a radiometric scale at the 0.1% level and better. Optical Technology Division TSI TRF Calibration against NIST POWR Page 15
16 Absolute Spectrally-Tunable Detector-Based Source Absolute detector measures radiance of single-line spectra These data are then used to set the spectral radiance scale use to calibrate spectroradiometer Spectrally-Tunable Source Absolute Radiance Detector Integrating Sphere currently lamp-based could be SC-based Apertures Si detector Control Computer Spectroradiometer Logging DVMs Spectroradiometer Input For more details, see Brown et al., Proc. SPIE 7807, 78070A (2010) Optical Technology Division TSI TRF Calibration against NIST POWR Page 16
17 Reflectance (ppm) Pressure (Torr) Reflectance (ppm) Stress-Induced Birefringence Changes Window Reflectance This common effect, though small with the 6 mm thick POWR window, was significant with the 3 mm thick TRF Radiometer window, and was corrected for both. POWR Window Reflectance: POWR Window Reflectance vs Time Venting from vacuum to atmosphere TRF Radiometer TRF Reflectance Window Vaccum-Air Reflectance: Cycles Alternating between vacuum and atmosphere Reflectance Pressure Cycle 1 Cycle 2 Cycle 3 Vacuum Closed Gate Valve Tweaked Window Alignment Here Atmosphere Time (s) Set Number Optical Technology Division TSI TRF Calibration against NIST POWR Page 17
18 Transmittance Transmittance Window Transmittance Scans in Air Relative window transmittance at 0 mm position was corrected. POWR Window POWR Window Transmittance Scans TRF Radiometer Window TRF Window Transmittance Scans Scan 1 Scan 2 Scan Scan 1 Scan 2 Scan Position (mm) Position (mm) Optical Technology Division TSI TRF Calibration against NIST POWR Page 18
Capabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments
Capabilities of NIST SIRCUS for Calibrations of SSI Vis-IR Instruments Steve Brown National Institute of Standards & Technology Gaithersburg, MD steve.brown@nist.gov; 301.975.5167 Answer: Ask LASP folks
More informationNIST Agency Report May 2012 OUTLINE. The case for traceability NMI capabilities A view to the future the HIP Current/recent NIST activities
NIST Agency Report May 2012 OUTLINE The case for traceability NMI capabilities A view to the future the HIP Current/recent NIST activities The case for traceability Earth Radiation Budget: Solar irradiance
More informationNew automated laser facility for detector calibrations
CORM annual conference, NRC, Ottawa, CANADA June 1, 2012 New automated laser facility for detector calibrations Yuqin Zong National Institute of Standards and Technology Gaithersburg, Maryland USA Overview
More informationIrradiance Calibration Using a Cryogenic Radiometer and a Broadband Light Source
Irradiance Calibration Using a Cryogenic Radiometer and a Broadband Light Source Jeff Morrill (1), Donald McMullin (2), Linton Floyd (3), Steven Lorentz (4), and Clarence Korendyke (1) (1) Naval Research
More informationTotal solar irradiance measurements with PREMOS/PICARD
Total solar irradiance measurements with PREMOS/PICARD Werner Schmutz, André Fehlmann, Wolfgang Finsterle, Greg Kopp, and Gerard Thuillier Citation: AIP Conf. Proc. 1531, 624 (2013); doi: 10.1063/1.4804847
More informationCU-LASP Test Facilities! and Instrument Calibration Capabilities"
CU-LASP Test Facilities! and Instrument Calibration Capabilities" Ginger Drake Calibration Group Manager 303-492-5899 Ginger.Drake@lasp.colorado.edu Thermal Vacuum Test Facilities" 2 Multiple Optical Beam
More informationThe TSIS Spectral Irradiance Monitor: Prism Optical Degradation Studies
The TSIS Spectral Irradiance Monitor: Prism Optical Degradation Studies Lo Erik Richard, Dave Harber, Joel Rutkowski, Matt Triplett, Kasandra O Malia Laboratory for Atmospheric and Space Physics (LASP)
More informationOf straying photons, shiny apertures and inconstant solar constants Advances in TSI radiometery
Of straying photons, shiny apertures and inconstant solar constants Advances in TSI radiometery SORCE 2014 Science Meeting, 29 January 2014 Wolfgang Finsterle Physikalisch-Meteorologisches Observatorium
More informationLegacy of NOAA, NASA and NIST Cooperation in Developing Radiometric Calibration Standards Equipment and Methodologies. Raju Datla, Michael Weinreb
Legacy of NOAA, NASA and NIST Cooperation in Developing Radiometric Calibration Standards Equipment and Methodologies CALCON 2012 Conference August 28, 2012 Raju Datla, Michael Weinreb Riverside Technology,
More informationStatus of Low-Background Infrared Calibration Facility at NIST
Status of Low-Background Infrared Calibration Facility at NIST Simon G. Kaplan #, Solomon I. Woods #, Julia Scherschligt #, Joseph P. Rice #, Adriaan C. Carter *, and Timothy M. Jung * # National Institute
More informationDevelopment of 2 Total Spectral Radiant Flux Standards at NIST
CIE/USA Annual Conference, October 7, 2014, Seattle, WA Development of 2 Total Spectral Radiant Flux Standards at NIST Yuqin Zong National Institute of Standards and Technology Gaithersburg, Maryland Outline
More informationResults of J1 VIIRS testing using NIST s Traveling SIRCUS
Results of J1 VIIRS testing using NIST s Traveling SIRCUS Steven W. Brown and Keith R. Lykke, NIST, Gaithersburg, MD Joel McCorkel, Brendan McAndrew, Gene Waluschka, and Jeff McIntire (Sigma Space), NASA
More informationACRIM3 Characterization by the LASP/TRF and the Total Solar Irradiance Database
ACRIM3 Characterization by the LASP/TRF and the Total Solar Irradiance Database ACRIM3 SCIENCE TEAM Dr. Richard C. Willson ACRIM Principal Investigator ACRIMSAT PROJECT Sandy Kwan JPL Project Manager Dr.
More informationMeasurements of Infrared Sources with the Missile Defense Transfer Radiometer
Measurements of Infrared Sources with the Missile Defense Transfer Radiometer Simon G. Kaplan #, Solomon I. Woods #, Adriaan C. Carter, and Timothy M. Jung * # National Institute of Standards and Technology
More informationLBIR Fluid Bath Blackbody for Cryogenic Vacuum Calibrations
LBIR Fluid Bath Blackbody for Cryogenic Vacuum Calibrations Timothy M. Jung*, Adriaan C. Carter*, Dale R. Sears*, Solomon I. Woods #, Dana R. Defibaugh #, Simon G. Kaplan #, Jinan Zeng * Jung Research
More informationTRACEABLE SOLAR RADIATION MEASUREMENTS
TRACEABLE SOLAR RADIATION MEASUREMENTS Julian Gröbner, Natalia Kouremeti, Gregor Hülsen, Stelios Kazadzis, Luca Egli Physikalisch-Meteorologisches Observatorium Davos, World Radiation Center (PMOD/WRC)
More informationRADIATION BUDGET INSTRUMENT (RBI): FINAL DESIGN AND INITIAL EDU TEST RESULTS
Place image here (10 x 3.5 ) RADIATION BUDGET INSTRUMENT (RBI): FINAL DESIGN AND INITIAL EDU TEST RESULTS RONALD GLUMB, JAY OVERBECK, CHRISTOPHER LIETZKE, JOHN FORSYTHE, ALAN BELL, AND JASON MILLER NON-EXPORT
More informationNIST EUVL Metrology Programs
NIST EUVL Metrology Programs S.Grantham, C. Tarrio, R.E. Vest, Y. Barad, S. Kulin, K. Liu and T.B. Lucatorto National Institute of Standards and Technology (NIST) Gaithersburg, MD USA L. Klebanoff and
More informationCurrent and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains
Measurement Science and Standards (MSS) Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains Arnold A. Gaertner Photometry, Radiometry and Thermometry (PRT) CORM 30
More informationRadiometric Measurement Traceability Paths for Photovoltaic Calibrations. Howard W. Yoon Physical Measurement Laboratory NIST
Radiometric Measurement Traceability Paths for Photovoltaic Calibrations Howard W. Yoon Physical Measurement Laboratory NIST Solar energy and PV Solar radiation: free and abundant! Photovoltaics (PV):
More informationRADIOMETRIC AND PHOTOMETRIC MEASUREMENTS AT THE LNE-INM/CNAM
RADIOMETRIC AND PHOTOMETRIC MEASUREMENTS AT THE LNE-INM/CNAM Jean Bastie, Laura Patricia Gonzalez Galvan. Institut National de Métrologie Conservatoire National des Arts et Métiers 61 rue du Landy 93210
More informationKazuhiro TANAKA GCOM project team/jaxa April, 2016
Kazuhiro TANAKA GCOM project team/jaxa April, 216 @ SPIE Asia-Pacific 216 at New Dehli, India 1 http://suzaku.eorc.jaxa.jp/gcom_c/index_j.html GCOM mission and satellites SGLI specification and IRS overview
More informationCalibration of a High Dynamic Range, Low Light Level Visible Source
Calibration of a High Dynamic Range, Low Light Level Visible Source Joe LaVeigne a, Todd Szarlan a, Nate Radtke a a Santa Barbara Infrared, Inc., 30 S. Calle Cesar Chavez, #D, Santa Barbara, CA 93103 ABSTRACT
More informationLASP / University of Colorado
The SORCE SIM Instrument: Progress Toward Spectral Irradiance Time Series Throughout the 300-3000 nm Region. Jerald Harder, Juan Fontenla, Byron Smiley, Sean Davis, George Lawrence and Gary Rottman LASP
More informationRadiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,
SORCE Science Meeting 29 January 2014 Mark Rast Laboratory for Atmospheric and Space Physics University of Colorado, Boulder Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,
More informationNIRCam optical calibration sources
NIRCam optical calibration sources Stephen F. Somerstein, Glen D. Truong Lockheed Martin Advanced Technology Center, D/ABDS, B/201 3251 Hanover St., Palo Alto, CA 94304-1187 ABSTRACT The Near Infrared
More informationDevelopment of Chinese SI-traceable reference instruments and retrospective recalibration of historical satellite data
GRWG Web Meeting Topic: Planning a GSICS/CEOS-WGCV Workshop on SI-traceable reference instruments Development of Chinese SI-traceable reference instruments and retrospective recalibration of historical
More informationCCT/10-13 MeP-K direct methods. Section 3.2: Absolute (spectral-band) radiometry (radiation thermometry)
CCT/10-13 MeP-K direct methods Section 3.2: Absolute (spectral-band) radiometry (radiation thermometry) Authors: Graham Machin (NPL, chair), Klaus Anhalt (PTB), Pieter Bloembergen (NIM, formerly NMIJ &
More informationCarbon Nanotube Radiometer for Cryogenic Calibrations
Carbon Nanotube Radiometer for Cryogenic Calibrations Solomon I. Woods a, Julia K. Scherschligt a, Nathan A. Tomlin b, John H. Lehman b a National Institute of Standards and Technology, 100 Bureau Drive,
More informationTSIS SIM Solar Spectral Irradiance: First Light and Early Observations
TSIS SIM Solar Spectral Irradiance: First Light and Early Observations Erik Richard, Dave Harber, Odele Coddington, Stéphane Béland, Laura Sandoval, Michael Chambliss, Steffen Mauceri, Peter Pilewskie,
More informationAdvances in Measuring UV LED Arrays
Advances in Measuring UV LED Arrays Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets May 8, 2018 Measurement Expectations Temperature Industrial thermometry: 1% accuracy Laboratory thermometry:
More informationDIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS
DIFFERENTIAL ABSORPTION LIDAR FOR GREENHOUSE GAS MEASUREMENTS Stephen E. Maxwell, Sensor Science Division, PML Kevin O. Douglass, David F. Plusquellic, Radiation and Biomolecular Physics Division, PML
More informationCHARACTERISTICS OF REMOTELY SENSED IMAGERY. Radiometric Resolution
CHARACTERISTICS OF REMOTELY SENSED IMAGERY Radiometric Resolution There are a number of ways in which images can differ. One set of important differences relate to the various resolutions that images express.
More informationRadiometric performance of Second Generation Global Imager (SGLI) using integrating sphere
Radiometric performance of Second Generation Global Imager (SGLI) using integrating sphere Taichiro Hashiguchi, Yoshihiko Okamura, Kazuhiro Tanaka, Yukinori Nakajima Japan Aerospace Exploration Agency
More informationBTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED. https://www.gigahertz-optik.de/en-us/product/bts2048-uv
BTS2048-UV https://www.gigahertz-optik.de/en-us/product/bts2048-uv Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED Gigahertz-Optik GmbH 1/8 Description UV CCD spectroradiometer
More informationIntegrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold
1354 MINIS Oriel Integrating Spheres Integrating spheres are ideal optical diffusers; they are used for radiometric measurements where uniform illumination or angular collection is essential, for reflectance
More informationIntercomparison of radiation temperature measurements over the temperature range from 1600 K to 3300 K
INSTITUTE OF PHYSICS PUBLISHING Metrologia 40 (2003) S39 S44 METROLOGIA PII: S0026-1394(03)56056-X Intercomparison of radiation temperature measurements over the temperature range from 1600 K to 3300 K
More informationmetcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -
metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 - ACTINIC FLUX SPECTRAL RADIOMETERS Ultra-fast CCD-Detector Spectrometer, UVB enhanced Cooled CCD, 512 pixel *
More informationBTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.
BTS2048-BS http://www.gigahertz-optik.de/en-us/product/bts2048-bs Product tags: VIS, Spectral Data, Industrial Applications, Laser Gigahertz-Optik GmbH 1/6 Description BTS2048-BS CCD spectroradiometer
More informationImproved Radiometry for LED Arrays
RadTech Europe 2017 Prague, Czech Republic Oct. 18, 2017 Improved Radiometry for LED Arrays Dr. Robin E. Wright 3M Corporate Research Process Laboratory, retired 3M 2017 All Rights Reserved. 1 Personal
More informationSpectroradiometer characterisations for traceable solar radiation measurements
Spectroradiometer characterisations for traceable solar radiation measurements Julian Gröbner, Natalia Kouremeti, Stelios Kazadzis, Gregor Hülsen, Luca Egli Physikalisch-Meteorologisches Observatorium
More informationThe Importance of Total Measured Optic Response in UV LED Measurement. Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets
The Importance of Total Measured Optic Response in UV LED Measurement Joe May, Jim Raymont, Mark Lawrence EIT Instrument Markets October 18, 2017 Measurement Expectations Temperature Industrial thermometry:
More informationJPSS1 VIIRS RSB Sensor calibration using monochromator-based and laser-based methods
JPSS1 VIIRS RSB Sensor calibration using monochromator-based and laser-based methods Jinan Zeng 1, Tom Schwarting 2, Jeff McIntire 2, Jack Ji 2, Hassan Oudrari 2, Jack Xiong 3, and Jim Butler 3 1 Fibertek
More informationKeysight Technologies Optical Power Meter Head Special Calibrations. Brochure
Keysight Technologies Optical Power Meter Head Special Calibrations Brochure Introduction The test and measurement equipment you select and maintain in your production and qualification setups is one of
More informationNIST MEASUREMENT SERVICES:
NIST Special Publication 250-37 NIST MEASUREMENT SERVICES: PHOTOMETRIC CALIBRATIONS Yoshihiro Ohno Optical Technology Division Physics Laboratory National Institute of Standards and Technology Gaithersburg,
More informationFull Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions
Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions Combining the Expertise of Two Industry Leaders to Give You An Immense Range of Complete Electro-Optical
More informationGround Truth for Calibrating Optical Imagery to Reflectance
Visual Information Solutions Ground Truth for Calibrating Optical Imagery to Reflectance The by: Thomas Harris Whitepaper Introduction: Atmospheric Effects on Optical Imagery Remote sensing of the Earth
More informationInstrumental and Methodological Developments in UV Research
Instrumental and Methodological Developments in UV Research Germar Bernhard Biospherical Instruments Inc, San Diego, CA Instrumental Developments Intercomparisons Correction Methods Methods for Interpreting
More informationMeasuring the Performance of UV LED Light Sources
Measuring the Performance of UV LED Light Sources Sink or Swim June 5, 2018 Jim Raymont EIT Instrument Markets Measurement Expectations Temperature Industrial thermometry: 1% accuracy Laboratory thermometry:
More informationNon-optically Combined Multi-spectral Source for IR, Visible, and Laser Testing
Non-optically Combined Multi-spectral Source for IR, Visible, and Laser Testing Joe LaVeigne a, Brian Rich a, Steve McHugh a, Peter Chua b a Santa Barbara Infrared, Inc., 30 S. Calle Cesar Chavez, #D,
More informationIt s Our Business to be EXACT
671 LASER WAVELENGTH METER It s Our Business to be EXACT For laser applications such as high-resolution laser spectroscopy, photo-chemistry, cooling/trapping, and optical remote sensing, wavelength information
More informationTechnical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration
Technical Notes Integrating Sphere Measurement Part II: Calibration This Technical Note is Part II in a three part series examining the proper maintenance and use of integrating sphere light measurement
More informationUnprecedented Resolution and Accuracy For Camera & Image Sensor Calibration
SpectralLED RS-7-1-VIS Benchtop Uniform Light Source For the ultimate in resolution and accuracy, the SpectralLED Tunable VIS source incorporates 35 discrete wavelengths for synthesis of commercially available
More informationInstruction Manual of Luminance and Spectral Radiance Calibrations
Aalto University School of Electrical Engineering Metrology Research Institute Jari Hovila Pasi Manninen Tuomas Poikonen Petri Kärhä Instruction Manual of Luminance and Version 2.6 07/12/2015 Page 2 (19)
More informationOL Series 426 Low Light Level lntegrating Sphere Calibration Standards
OL Series 426 Low Light Level lntegrating Sphere Calibration Standards GENERAL The OL Series 426 Low-Light-Level Calibration Standard is designed for accurately calibrating very sensitive microphotometers,
More informationSolid State Luminance Standards
Solid State Luminance Standards Color and luminance correction of: - Imaging colorimeters - Luminance meters - Imaging spectrometers Compact and Robust for Production Environments Correct for instrument
More informationZenith Polymer Diffuse Reflectance Standards, Targets and Materials. ... your Partner in Lighting Technology!
Zenith Polymer Diffuse Reflectance Standards, Targets and Materials For use over the UV, VIS and NIR spectral regions... your Partner in Lighting Technology! Properties of Zenith Polymer optical PTFE All
More informationNIST Measurement Services: cw Laser Power and Energy Calibrations at NIST
NIST Measurement Services: cw Laser Power and Energy Calibrations at NIST NIST Special Publication 250-75 Joshua Hadler Christopher L. Cromer John H. Lehman T he National Institute of Standards and Technology
More informationWhite Paper on SWIR Camera Test The New Swux Unit Austin Richards, FLIR Chris Durell, Joe Jablonski, Labsphere Martin Hübner, Hensoldt.
White Paper on Introduction SWIR imaging technology based on InGaAs sensor products has been a staple of scientific sensing for decades. Large earth observing satellites have used InGaAs imaging sensors
More informationOptical and Quantum Electronics (2005) 37: Ó Springer 2005 DOI /s
Optical and Quantum Electronics (2005) 37:529 543 Ó Springer 2005 DOI 10.1007/s11082-005-3955-5 Cryogenic radiometer based absolute spectral power responsivity calibration of integrating sphere radiometer
More informationOutline for today. Geography 411/611 Remote sensing: Principles and Applications. Remote sensing: RS for biogeochemical cycles
Geography 411/611 Remote sensing: Principles and Applications Thomas Albright, Associate Professor Laboratory for Conservation Biogeography, Department of Geography & Program in Ecology, Evolution, & Conservation
More informationGLOSSARY OF TERMS. Terminology Used for Ultraviolet (UV) Curing Process Design and Measurement
GLOSSARY OF TERMS Terminology Used for Ultraviolet (UV) Curing Process Design and Measurement This glossary of terms has been assembled in order to provide users, formulators, suppliers and researchers
More informationBroadbandradiometer specbos 1211
Broadbandradiometer specbos 1211 specbos 1211 is a broadband and fast spectroradiometer which can be used in laboratory as well as production environment to measure the following quantities: Luminance,
More informationProgram for UV Intercomparison 2014 in Davos:
Program for UV Intercomparison 2014 in Davos: June 2014 Date: 7 16 July 2014 Location: PMOD/WRC Davos Switzerland. Information Update: http://projects.pmodwrc.ch/env03/index.php/8-emrp-uv/project/24- intercomparison-2014
More informationEvaluating calibrations of normal incident pyrheliometers
Evaluating calibrations of normal incident pyrheliometers Frank Vignola Department of Physics University of Oregon fev@uoregon.edu Fuding Lin Department of Chemistry University of Oregon flin@uoregon.edu
More informationAVHRR/3 Operational Calibration
AVHRR/3 Operational Calibration Jörg Ackermann, Remote Sensing and Products Division 1 Workshop`Radiometric Calibration for European Missions, 30/31 Aug. 2017`,Frascati (EUM/RSP/VWG/17/936014) AVHRR/3
More informationMUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM
MUSKY: Multispectral UV Sky camera Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM Outline Purpose of the instrument Required specs Hyperspectral or multispectral? Optical design
More informationThe ASTRI SST-2M Illuminator
CTA Calibration Meeting Universidade de São Paulo Instituto de Astronomia, Geofisica e Ciencias Atmosferica The ASTRI SST-2M Illuminator A. Segreto, G. La Rosa INAF Palermo for the ASTRI Collaboration
More informationChameleon Spectroradiometer
Chameleon Spectroradiometer SPEED / STABILITY / ACCURACY The Chameleon Series is designed to measure the absolute spectral of power, of the light under test. Adding optical probes and absolute calibration
More informationMiniaturized Spectroradiometer
Miniaturized Spectroradiometer Thomas Morgenstern, Gudrun Bornhoeft, Steffen Goerlich JETI Technische Instrumente GmbH, Jena, Germany Abstract This paper describes the basics of spectroradiometric instruments
More informationSPECTRAL IRRADIANCE DATA
The radiometric data on the following pages was measured in our Standards Laboratory. The wavelength calibrations are based on our spectral calibration lamps. Irradiance data from 250 to 2500 nm is based
More informationCharacterisation of New Planar Cryogenic Radiometric Standards under Development at NIST
Characterisation of New Planar Cryogenic Radiometric Standards under Development at NIST Malcolm White CALCON 2016 National Institute of Standards and Technology 325 Broadway, Boulder, Colorado 80305-3228
More informationEffect of Beam Size on Photodiode Saturation
Effect of Beam Size on Photodiode Saturation Experiments were conducted to demonstrate a change in the saturation point for a FDS1010 silicon photodiode as a function of beam diameter. The saturation point
More informationMeasuring the Light Output (Power) of UVC LEDs. Biofouling Control Using UVC LEDs
Biofouling Control Using UVC LEDs NOVEMBER 1, 2016 Measuring the Light Output (Power) of UVC LEDs This application note outlines an approach for customers to measure UVC LED power output with a pulse mode
More informationCross Track Infrared Sounder (CrIS) Flight Model 1 Test Results
May 6, 2009 Ronald Glumb, Joseph P. Predina, Robert Hookman, Chris Ellsworth, John Bobilya, Steve Wells, Lawrence Suwinski, Rebecca Frain, and Larry Crawford For Publication at the ASS-FTS14 Conference
More informationISS-30-VA. Product tags: Integrating Sphere Source. https://www.gigahertz-optik.de/en-us/product/iss-30-va. Gigahertz-Optik GmbH 1/5
ISS-30-VA https://www.gigahertz-optik.de/en-us/product/iss-30-va Product tags: Integrating Sphere Source Gigahertz-Optik GmbH 1/5 Description standards for spectral radiance Spectroradiometers and other
More informationMeasurement Services Optics Laboratory
Federal Institute of Metrology METAS CH-3003 Bern-Wabern, 1. February 2018 Measurement Services Optics Laboratory Valid from: 01.02.2018 In our laboratory we perform high accuracy calibrations of your
More informationUV-VIS-IR Spectral Responsivity Measurement System for Solar Cells
November 1998 NREL/CP-52-25654 UV-VIS-IR Spectral Responsivity Measurement System for Solar Cells H. Field Presented at the National Center for Photovoltaics Program Review Meeting, September 8 11, 1998,
More informationMETimage Calibration & Performance Verification. Xavier Gnata ICSO 2016
METimage Calibration & Performance Verification Xavier Gnata ICSO 2016 METimage factsheet Mission Passive imaging radiometer (multi-spectral) 20 spectral channels (443 13.345nm) Global coverage within
More informationENMAP RADIOMETRIC INFLIGHT CALIBRATION, POST-LAUNCH PRODUCT VALIDATION, AND INSTRUMENT CHARACTERIZATION ACTIVITIES
ENMAP RADIOMETRIC INFLIGHT CALIBRATION, POST-LAUNCH PRODUCT VALIDATION, AND INSTRUMENT CHARACTERIZATION ACTIVITIES A. Hollstein1, C. Rogass1, K. Segl1, L. Guanter1, M. Bachmann2, T. Storch2, R. Müller2,
More informationSpectral responsivity uncertainty of silicon photodiodes due to calibration spectral bandwidth
INSTITUTE OF PHYSICS PUBLISHING Meas. Sci. Technol. 12 (2001) 1926 1931 MEASUREMENT SCIENCE AND TECHNOLOGY Spectral responsivity uncertainty of silicon photodiodes due to calibration spectral bandwidth
More informationCIRiS: Compact Infrared Radiometer in Space August, 2017
1 CIRiS: Compact Infrared Radiometer in Space August, 2017 David Osterman PI, CIRiS Mission Presented by Hansford Cutlip 10/8/201 7 Overview of the CIRiS instrument and mission The CIRiS instrument is
More informationJam Lab Capabilities. Charles Dionne. Matthew Pilat. Jam Lab Manager
Jam Lab Capabilities Charles Dionne Jam Lab Manager charles.e.dionne@baesystems.com Matthew Pilat Senior Systems Engineer matthew.pilat@baesystems.com 1 Infrared Countermeasure (IRCM) Jam Lab Capabilities
More informationThe Standard for over 40 Years
Light Measurement The Standard for over 40 Years Introduction LI-COR radiation sensors measure the flux of radiant energy the energy that drives plant growth, warms the earth, and lights our world. The
More informationResearch Support Instruments, Inc., Boulder, CO b. Goddard Space Flight Center, Greenbelt, MD c
SR-935 Characterization of a hardened ultrastable UV linear variable filter and recent results on the radiometric stability of narrow band interference filters subjected to temperature/humidity, thermal/vacuum
More informationInfluence of the light spectral distribution used in the radiometers calibration
Influence of the light spectral distribution used in the radiometers calibration J C Moraes and L O Guerra Allergisa Pesquisa Dermato-Cosmética Ltda GRUPO INVESTIGA, 452. Dr. Romeu Tórtima Avenue, Postcode:
More informationA Laser-Driven Light Source (LDLS) as a portable spectral irradiance calibration source in the UV range and other radiometric applications.
A Laser-Driven Light Source (LDLS) as a portable spectral irradiance calibration source in the UV range and other radiometric applications. O. El Gawhary 1, S. van den Berg 1, N. van der Leden 1, P. Dekker
More informationSpatially Resolved Backscatter Ceilometer
Spatially Resolved Backscatter Ceilometer Design Team Hiba Fareed, Nicholas Paradiso, Evan Perillo, Michael Tahan Design Advisor Prof. Gregory Kowalski Sponsor, Spectral Sciences Inc. Steve Richstmeier,
More informationThe Issues of Measurement of Optical Hazard Using Photometers EMRP JRP ENG05 Metrology for Solid State Lighting
The Issues of Measurement of Optical Hazard Using Photometers EMRP JRP ENG05 Metrology for Solid State Lighting Simon Hall,Paul Miller, Neil Haigh, Ben Thornton, Neil Haigh (Lux TSI) 25 th April 2013 Background
More informationHyperspectral Systems: Recent Developments and Low Cost Sensors. 56th Photogrammetric Week in Stuttgart, September 11 to September 15, 2017
Hyperspectral Systems: Recent Developments and Low Cost Sensors 56th Photogrammetric Week in Stuttgart, September 11 to September 15, 2017 Ralf Reulke Humboldt-Universität zu Berlin Institut für Informatik,
More informationRailroad Valley Playa for use in vicarious calibration of large footprint sensors
Railroad Valley Playa for use in vicarious calibration of large footprint sensors K. Thome, J. Czapla-Myers, S. Biggar Remote Sensing Group Optical Sciences Center University of Arizona Introduction P
More informationIntroduction to the operating principles of the HyperFine spectrometer
Introduction to the operating principles of the HyperFine spectrometer LightMachinery Inc., 80 Colonnade Road North, Ottawa ON Canada A spectrometer is an optical instrument designed to split light into
More informationInstruction manual for Ocean Optics USB4000 and QE65 Pro spectroradiometers
Aalto University School of Electrical Engineering Metrology Research Institute Hans Baumgartner Instruction manual for Version 1.0 24/11/2016 Page 2 (9) 1. Table of contents 1. Table of contents... 2 2.
More informationApplication Note (A16)
Application Note (A16) Eliminating LED Measurement Errors Revision: A December 2001 Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1 407 422 3171 Fax: 1 407 648 5412 Email: sales@goochandhousego.com
More informationAn Introduction to Remote Sensing & GIS. Introduction
An Introduction to Remote Sensing & GIS Introduction Remote sensing is the measurement of object properties on Earth s surface using data acquired from aircraft and satellites. It attempts to measure something
More informationNEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET
REPLACE NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET 9925 Carroll Canyon Road San Diego, CA 92131 (800) 637-2758 (858) 279-8034 Fax (858) 576-9286 www.gamma-sci.com About Gamma Scientific:
More information\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä
\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä Ultraviolet Radiation from Some Types of Outdoor Lighting Lamps Dr.Essam El-Moghazy Photometry and Radiometry division, National Institute for Standards (NIS), Egypt.
More informationModel S471-LED Optometer
Model S471-LED Optometer For over 40 years UDT Instruments, a Gamma Scientific company, has been trusted by the world s leading organizations to provide accurate light measurement systems. UDT Instruments
More informationA simple null-field ellipsometric imaging system (NEIS) for in situ monitoring of EUV-induced deposition on EUV optics
A simple null-field ellipsometric imaging system (NEIS) for in situ monitoring of EUV-induced deposition on EUV optics Rashi Garg 1, Nadir Faradzhev 2, Shannon Hill 3, Lee Richter 3, P. S. Shaw 3, R. Vest
More informationMetrology for QKD an industrial quantum optical communication technology
Metrology for QKD an industrial quantum optical communication technology Christopher Chunnilall christopher.chunnilall@npl.co.uk 1 st ETSI Quantum-Safe-Crypto-Workshop Sophia-Antipolis, France 26-27 September
More information