Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration"

Transcription

1 SpectralLED RS-7-1-VIS Benchtop Uniform Light Source For the ultimate in resolution and accuracy, the SpectralLED Tunable VIS source incorporates 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rocksolid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration KEY FEATURES Constant Current Drivers & Built-in Optical Feedback Accurate & Flicker-free Output in Real Time All Solid-State Design for Rapid Start-up, Repeatable Performance ISO/IEC Accredited by NVLAP (NVLAP lab code ) for Calibration Accuracy APPLICATION AREAS Camera and Image Sensor Calibration Photodiode Detector Responsivity Characterization Spectrum / Illuminant Simulation Diagnostic MedicalImaging Technical and Industrial Photography

2 SpectralLED RS-7-1-VIS Uniform Light Source RS-7-1 OPTICAL SPECIFICATIONS Measurement Applications White Balance Quantum Efficiency Spatial Non-uniformity Pixel Defects Crosstalk Vignetting Correction Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Spectral Output Spectral Peaks Spectral Bandwidth Source Geometry Spatial Uniformity 32 discrete LED channels, 3 broadband LED channels Visible resolution ~ 15nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configs available) Typical VIS of 20nm and NIR of 50nm FWHM 75mm dia, Lambertian radiant source (see RS-7-2 models for exit ports up to 600 mm dia) 97% over 8 field of view Radiance Range Typical maximum of 15,000 µw / cm 2 / sr Typical minimum of 15 µw / cm 2 / sr Luminance Range Typical maximum of 30,000 cd / m 2 Typical minimum of 30 cd / m 2 CCT Range 1,900K to 40,000K Sensitivity Preset Spectra CIE illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM patches Responsivity Signal to noise Linearity ISO Speed Saturation Exposure Dynamic range ACCURACY SPECIFICATIONS Illumination Stability 99.99% after 50 ms for radiance or after 2,000 ms for spectrum Illumination Accuracy ± 1% Absolute, NIST traceable Spectral Accuracy ± 1 nm centroid wavelength Color Accuracy CIE 1931 x,y ± Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (typical, channel dependent) Gamma Scientific is ISO/IEC accredited by NVLAP (NVLAP lab code ) and performs Electrical Resolution ELECTRICAL SPECIFICATIONS 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS LM-79 / LM- 80 LED testing. Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage & Power Dimensions (H x W x L) RS-7 Wavemon RS-7-IRIS Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum 405mm (16 in) x 460mm (18.1in) x (305mm (12in). Weight 17.5 kg (38.6 lbs) OPTIONAL UPGRADES Multi-channel photodiode system w / amplitude feedback & real-time ƛ measurements Integrated IRIS w/ stepper motor control & additional API commands for easy adjustment Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev Carroll Canyon Rd San Diego, CA Phone:

3 SpectralLED RS-7-1-SWIR Benchtop Uniform LightSource For the ultimate in resolution and accuracy, the SpectralLED Tunable SWIR source incorporates 9 shortwave infrared wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For SWIR Camera & Image Sensor Calibration KEY FEATURES Gold Coated Integrating Sphere Constant Current Drivers & Built-in Optical Feedback Accurate & Flicker-free Output in Real Time All Solid-State Design for Rapid Start-up & Repeatable Performance ISO/IEC Accredited by NVLAP (NVLAP lab code ) for Calibration Accuracy APPLICATION AREAS Camera and Image SensorCalibration Photodiode Detector Responsivity Characterization Spectrum / Illuminant Simulation Diagnostic Medical Imaging Technical and Industrial Photography

4 RS-7-3-SWIR Fiber Optic Output Flexible illumination for applications where space is limited Can be configured with multiple outputs enabling several devices to be simultaneously illuminated at different locations Integrated collimating optics at fiber distal end Custom fiber diameters and lengths available RS-7-4-SWIR Wafer Probe Directly replaces lamp-based sensor testers already deployed in the field Easily programmed to deliver virtually any desired spectral power distribution of SWIR light All solid-state design maintains calibration & eliminates downtime associated with lamp replacement RS-7-5-SWIR Baffle Output 150mm output with irradiancecalibration Includes an integrated baffle tube with 150mm clear aperture User adjustable f-numbers including f/1, f/2, f/3 and f/4 Ideal for testing of bare sensors RS-7-6-SWIR Wide Field of View For applications requiring Wide Field of View (up to 180 degrees) Optical design delivers equal radiance over the entire Field of View Ideal for flat fielding fish eye or ultra-wide field of view lens designs 75mm output port with >98%uniformity

5 SpectralLED Calibration & Test of Night Vision Equipment MEASUREMENT PARAMETERS Quantum Efficiency Spatial Non-uniformity Pixel Defects Remote Sensing Image Calibration Crosstalk Vignetting Correction Responsivity Signal-to-noise Linearity ISO Speed Remote Sensing Equipment Manufacturing Dynamic Range Sensitivity Hyperspectral Imaging Industrial monitoring, Security & Defense, Semiconductor Equipment

6 SpectralLED RS-7-1-SWIR Benchtop Uniform Light Source OPTICAL SPECIFICATIONS Spectral Range 900 nm to 1,700 nm (Custom ranges available on request) Spectral Output Spectral Peaks Spectral Bandwidth Custom Preset Spectra 9 discrete LED channels SWIR resolution ~ 50 nm (typical channel spacing) 910nm, 940nm, 980nm, 1050nm, 1200nm, 1300nm, 1450nm, 1550nm, 1650nm (custom configurations available) Typical of nm FWHM (channel dependent) Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS Illumination Stability Illumination Accuracy Spectral Accuracy Linearity Temperature Stability 99.99% after 50 ms for radiance or after 2,000 ms for spectrum ± 3% Absolute, NIST traceable ± 2.5 nm centroid wavelength < 0.1 % RMS of full scale Within ± 1 C via active TEC ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Varies according to specific part number configuration, please contact factory for details PART NUMBER CONFIGURATIONS RS-7-1-SWIR RS-7-3-SWIR RS-7-4-SWIR RS-7-5-SWIR RS-7-6-SWIR 75mm output port, 200mm gold coated integrating sphere Fiber Optic Output light delivery via one or more fiber bundles Wafer Probe Illuminator for wafer level testing of CCD and CMOS sensors Baffle Tube Output with 150 mm clear aperture with user adjustable f-number Wide Field of View with Gold coating providing high uniformity at up to 180 degree viewing angle Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev Carroll Canyon Rd San Diego, CA Phone:

7 SpectralLED RS-7-2-VIS Tunable Light Source - Large Output Port When you require a large area, highly uniform light source for camera and image sensor calibration, the SpectralLED Large Output Port delivers brightness, radiometric stability and wavelength accuracy that is unmatched in the industry. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistentresults. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X- RITE ColorPatch Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time Sphere Diameter Max Exit Port Diameter Number of SpectralLED 0.5 m 150 mm m 300 mm 1 to m 600 mm 2 to 8 All Solid-State Design for Rapid Start-up, Repeatable Performance and Long Operating Lifetime ISO/IEC Accredited by NVLAP (NVLAP lab code ) for Calibration Accuracy

8 SpectralLED RS-7-2-VIS Large Output Port RS-7-2-VIS SPECIFICATIONS Measurement Applications White Balance Quantum Efficiency Spatial Non-uniformity Pixel Defects Crosstalk Vignetting Correction Sensitivity Responsivity Signal to noise Source Geometry Spatial Uniformity 99% Optical Geometry Radiance Range Luminance Range 150mm, 300mm or 600mm diameter uniform output, Lambertian radiant source (Other output port sizes available on request) Integrating sphere with 500mm, 1,000mm or 1,500mm diameter (Other sphere sizes available on request) Dependent upon integrating sphere size and number of light engines attached. Please consult with factory for configuration parameters and output specifications. OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Spectral Output Spectral Peaks Spectral Bandwidth CCT Range 1,900K to 40,000K 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 585nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Typical: Visible 20nm FWHM, NIR 50nm FWHM Linearity ISO Speed Saturation Exposure Dynamic range Preset Spectra Custom Preset Spectra Illumination Stability Illumination Accuracy Spectral Accuracy CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Gamma Scientific is ISO/IEC accredited by NVLAP (NVLAP lab code ) and performs LM-79 / LM-80 LED testing. Color Accuracy CIE 1931 x, y ± Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Light Engine Dimensions Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Dependent on integrating sphere chosen please contact factory for details UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice. Gamma Scientific, All Rights Reserved Rev Carroll Canyon Rd San Diego, CA Phone:

9 SpectralLED RS-7-3-VIS Tunable Light Source - Fiber Optic Output The SpectralLED Fiber Optic Output configuration provides flexible illumination for applications where space is limited. Systems can be configured with multiple outputs enabling several devices to be simultaneously illuminated at different working locations. Collimating optics are included at the fiber distal end, and custom fiber diameters and lengths areavailable. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X- RITE ColorPatch Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Fiber Outputs Fiber Length Fiber Diameter m 6.35 mm [Most systems are custom configured please consult factory] Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time All Solid-State Design for Rapid Start-up, Repeatable Performance and Long Operating Lifetime ISO/IEC Accredited by NVLAP (NVLAP lab code ) for Calibration Accuracy

10 SpectralLED RS-7-3-VIS Fiber Optic Output RS-7-3-VIS SPECIFICATIONS Measurement Applications Optical Geometry Spatial Uniformity Radiance Range Luminance Range Typically 0.55 NA (fiber dependent) Typically > 70% (fiber dependent) Up to 500 µw/cm 2 (at 5cm, fiber and spectrum dependent) Up to 1,000 lux (fiber and spectrum dependent) White Balance Quantum Efficiency Spatial Non-uniformity Pixel Defects Crosstalk Vignetting Correction Sensitivity Responsivity Signal to noise Linearity ISO Speed Saturation Exposure Dynamic range Gamma Scientific is ISO/IEC accredited by NVLAP (NVLAP lab code ) and performs LM-79 / LM-80 LED testing. OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges are available on request, including SWIR options) Spectral Output Spectral Peaks Spectral Bandwidth CCT Range 1,900K to 40,000K Preset Spectra Custom Preset Spectra Illumination Stability Illumination Accuracy Spectral Accuracy 32 discrete LED channels + 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Typical: Visible 20nm FWHM, NIR 50nm FWHM CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Color Accuracy CIE 1931 x, y ± Linearity Temperature Stability < 1 % RMS of full scale Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Height 405mm (16 in), Width 460mm (18.1in), Depth (305mm (12in). Weight 17.5 kg (38.6 lbs) UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev Carroll Canyon Rd San Diego, CA Phone:

11 SpectralLED RS-7-4-VIS Tunable Light Source Wafer Probe Illuminator The SpectralLED Wafer Probe Illuminator is an all solidstate, drop-in replacement for field-deployed wafer-level CCD and CMOS sensor testers. The system is fully turnkey, and can readily be adapted to test head manipulators and handler instrumentation. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. Theplatform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration All Solid-State Design for Rapid Start-up, Repeatable Performance and Maximum Up-time Wavelength Options From the UVA to the NearInfrared Quickly Simulate any CIE Illuminant or Macbeth / X- RITE ColorPatch Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time ISO/IEC Accredited by NVLAP (NVLAP lab code ) for Calibration Accuracy System Compatibility ü Agilent ü Teradyne ü National Instruments ü Yokogawa ü Advantest ü Cascade Microtech

12 SpectralLED RS-7-4-VIS Wafer Probe Illuminator Measurement Applications OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Spectral Output 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) White Balance Quantum Efficiency Spatial Non-uniformity Spectral Peaks Spectral Bandwidth 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Typical: Visible 20nm FWHM, NIR 50nm FWHM Pixel Defects Crosstalk Vignetting Correction Sensitivity Responsivity Signal to noise Linearity ISO Speed Saturation Exposure Dynamic range Gamma Scientific is ISO/IEC CCT Range 1,900K to 40,000K Preset Spectra CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Custom Preset Spectra Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS Illumination Stability 99.99% after 50 ms for radiance or after 2,000 ms for color Illumination Accuracy ± 1% Absolute, NIST traceable Spectral Accuracy ± 1 nm centroid wavelength Color Accuracy CIE 1931 x, y ± Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS accredited by NVLAP (NVLAP lab code ) and performs LM-79 / LM-80 LED testing. Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions RS-7 Wavemon Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Please contact factory for details UPGRADES Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev Carroll Canyon Rd San Diego, CA Phone:

13 SpectralLED RS-7-5-VIS Tunable Light Source Baffle Tube Output The SpectralLED Baffle Tube Output features a 150 mm clear aperture with user interchangeable baffle tubes for adjustable f- numbers of f/1, f/2, f/3 and f/4. The unit is ideally suited for testing of bare sensors in an R&D or productionenvironment. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration All Solid-State Design for Rapid Start-up, Repeatable Performance and Maximum Up-time Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X- RITE ColorPatch Number of Baffle Tubes f-number 1 (attached) f/1 2 f/2 3 f/3 4 f/4 Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time ISO/IEC Accredited by NVLAP (NVLAP lab code ) for Calibration Accuracy

14 SpectralLED RS7-5-VIS Baffle Tube Output Measurement Applications RS-7-5-VIS SPECIFICATIONS Source Geometry 150mm diameter uniform output with Baffle Tube irradiance source Spatial Uniformity 95% Optical Geometry Specialized design for user adjustable f-number White Balance Quantum Efficiency Spatial Non-uniformity Radiance Range Depends on f-number and spectrum. Contact factory for details. Luminance Range OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Pixel Defects Crosstalk Vignetting Correction Sensitivity Spectral Output Spectral Peaks 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Responsivity Signal to noise Linearity ISO Speed Spectral Bandwidth Typical: Visible 20nm FWHM, NIR 50nm FWHM CCT Range 1,900K to 40,000K Preset Spectra CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Custom Preset Spectra Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS Saturation Exposure Dynamic range Illumination Stability Illumination Accuracy Spectral Accuracy 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Gamma Scientific is ISO/IEC accredited by NVLAP (NVLAP lab code ) and performs LM-79 / LM-80 LED testing. Color Accuracy CIE 1931 x, y ± Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions (1) Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Height 405mm (16 in), Width 460mm (18.1in), Depth (305mm (12in). Weight 17.5 kg (38.6 lbs) UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice (1) Does not include Baffle Tube Gamma Scientific, All Rights Reserved Rev Carroll Canyon Rd San Diego, CA Phone:

15 SpectralLED RS-7-6-VIS Tunable Light Source Wide Field of View The SpectralLED Wide Field of View (FOV) is ideally suited for applications requiring a field of view up to 180. The unique optical design delivers equal radiance over the entire field, which is critical for users desiring flat fielding fisheye or ultra-wide FOV lens designs. With better than 97% uniformity across the 75mm output, the performance is unmatched in the industry. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. Theplatform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration All Solid-State Design for Rapid Start-up, Repeatable Performance and Maximum Up-time Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X-RITE Color Patch Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time] ISO/IEC Accredited by NVLAP (NVLAP lab code ) for Calibration Accuracy

16 SpectralLED RS-7-6-VIS Wide Field of View Measurement Applications Source Geometry Spatial Uniformity Optical Geometry RS-7-6-VIS SPECIFICATIONS 75mm diameter uniform output with 180 field of view. Lambertian radiant source. 95% over 180 (2π steradians) Built-in integrating cavity. Specialized optical design for user adjustable spot parameters. White Balance Quantum Efficiency Spatial Non-uniformity Radiance Range Typical maximum of 2,500µW/cm 2 /sr Typical minimum of 2.5µW/cm 2 /sr (spectrum dependent) Luminance Range Typical maximum of 5,000cd/m 2 Typical minimum of 5 cd/cm 2 (spectrum dependent) OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Pixel Defects Crosstalk Vignetting Correction Sensitivity Spectral Output Spectral Peaks 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Responsivity Signal to noise Linearity ISO Speed Spectral Bandwidth Typical: Visible 20nm FWHM, NIR 50nm FWHM CCT Range 1,900K to 40,000K Preset Spectra CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Custom Preset Spectra Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS Saturation Exposure Dynamic range Illumination Stability Illumination Accuracy Spectral Accuracy 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Gamma Scientific is ISO/IEC accredited by NVLAP (NVLAP lab code ) and performs LM-79 / LM-80 LED testing. Color Accuracy CIE 1931 x, y ± Linearity < 0.1 % RMS of full scale Temperature Stability Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Software Interface Connectors Interface Protocol Supported Operating Systems Input Voltage and Power Dimensions Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum Height 405mm (16 in), Width 460mm (18.1in), Depth (305mm (12in). Weight 17.5 kg (38.6 lbs) UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev Carroll Canyon Rd San Diego, CA Phone:

17 SpectralLED RS-7-7-VIS Tunable Light Source Light Booth The SpectralLED Light Booth quickly simulates virtually infinite lighting conditions enabling visual color assessment for photography, product display or lighting design applications. Both real and theoretical lighting conditions can be produced, enabling CRI experimentation, analysis and optimization. The SpectralLED Tunable Light Source incorporates up to 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. Theplatform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results. Unprecedented Resolution and Accuracy For CRI Experimantation, Analysis & Optimization All Solid-State Design for Rapid Start-up, Repeatable Performance and Long Operating Lifetime Built-in RMS Spectral Fitting for Simulation of User Imported Spectra Wavelength Options From the UVA to the Near Infrared Quickly Simulate any CIE Illuminant or Macbeth / X-RITE Color Patch Constant Current Drivers & Built-in Optical Feedback Ensure Accurate & Flicker-free Output in Real Time ISO/IEC Accredited by NVLAP (NVLAP lab code ) for Calibration Accuracy

18 SpectralLED RS-7-7-VIS Light Booth Measurement Applications White Balance Quantum Efficiency Spatial Non-uniformity Pixel Defects Crosstalk Vignetting Correction Sensitivity Responsivity Signal to noise Linearity ISO Speed Saturation Exposure Dynamic range Gamma Scientific is RS-7-7-VIS OPTICAL SPECIFICATIONS Spectral Range 380 nm to 1,000 nm (Custom ranges available on request) Spectral Output Spectral Peaks Spectral Bandwidth CCT Range 1,900K to 40,000K Preset Spectra Custom Preset Spectra Illumination Stability Illumination Accuracy Spectral Accuracy 32 discrete LED channels, 3 broadband LED Channels Visible resolution ~ 15 nm, NIR resolution ~ 50 nm (typical channel spacing) 395nm, 405nm, 420nm, 430nm, 450nm, 460nm, 475nm, 495nm, 505nm, 520nm, 525nm, 535nm, 570nm, 595nm, 610nm, 700nm, 620nm, 630nm, 637nm, 660nm, 675nm, 685nm, 715nm, 730nm, 750nm, 760nm, 780nm, 805nm, 850nm, 895nm, 940nm, 965nm 2,700K Warm White, 3,000K Warm White, 6,500K Cool White (Custom configurations available) Typical: Visible 20nm FWHM, NIR 50nm FWHM CIE Illuminants A, B, C, D50, D55, D65, D75, E, F1-F12, Macbeth TM / X-Rite TM Color Patches Configurable at time of order via API. Contact factory for details ACCURACY SPECIFICATIONS 99.99% after 50 ms for radiance or after 2,000 ms for color ± 1% Absolute, NIST traceable ± 1 nm centroid wavelength Color Accuracy CIE 1931 x, y ± Linearity Temperature Stability < 0.1 % RMS of full scale Within ± 1 C via active TEC Long-term Drift Output 2% Spectral 1 nm (channel dependent) ELECTRICAL SPECIFICATIONS Electrical Resolution 16 bit DAC for channel current drivers 24 bit ADC for internal radiance monitor feedback ISO/IEC accredited by NVLAP (NVLAP lab code ) and performs LM-79 / LM-80 LED testing. Dynamic Range Adjustment 4-5 decades typical (spectrum dependent) LED Control Software Interface Connectors Interface Protocol Pure DC constant current with floating differential sensing GENERAL SPECIFICATIONS Firmware includes full spectral calibration with spectral fitting, preset storage, real-time optical feedback, radiometric and photometric units supported USB 2.0 type B and DB-9 Simple ASCII commands with optional binary block transfer Supported Operating Systems Input Voltage and Power Interior Dimensions USB drivers for Windows, OSX and Linux via FTDI virtual COM port Legacy RS-232 serial port for integration (no OS required) 110 to 240 VAC at 50-60Hz, 600W maximum 45 x 45 x 45 cm (preliminary) UPGRADES RS-7 Wavemon Multi-channel photodiode system provides amplitude feedback & real-time wavelength measurements Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev Carroll Canyon Rd San Diego, CA Phone:

19 RS-7 Wavemon TM Option The Wavemon TM Wavelength Monitor System upgrade is a multi-channel photodiode system that provides amplitude feedback and real-time wavelength measurements. It consists of three photodiodes each with an independent transimpedance amplifier circuit, with 5 gain ranges for each channel. Proprietary optical filtering techniques allow for wavelength accuracy of +/- 0.25nm and repeatability of +/-0.05nm using only 3 photodiode channels. The Wavelength Monitor PCBA, photodiodes, and optical filter assembly are temperature stabilized using a Peltier cooler and thermistor in a PID feedback loop. Real-time Amplitude & Wavelength Monitoring Unmatched Accuracy and Repeatability Sub-nanometer Wavelength Measurement Accuracy ± 1% Irradiance Measurement Accuracy ASCII Command Set for Simple Device Control 5 Gain Stages per Channel for Increased Dynamic Range Built-in Thermal Regulation for Long-term Stability On-board Unit-specific Calibration Data ISO/IEC Accredited by NVLAP (NVLAP lab code ) for Calibration Accuracy The SpectralLED family of tunable light sources incorporate 35 discrete wavelengths for synthesis of commercially available light sources or based on spectra that you import. The platform is easily adaptable for automated test systems and production line integration, with integrated optical feedback and temperature control to ensure rock-solid stability and consistent results

20 RS-7 Wavemon TM Option ACCURACY SPECIFICATIONS Spectral Range 365 nm to 1,100 nm (Short Wave Infrared options possible) Wavelength Absolute Accuracy Wavelength Repeatability ± 0.25 nm ± 0.01 nm Irradiance Absolute Accuracy ± 1% Irradiance Repeatability / Stability 0.1% ELECTRICAL SPECIFICATIONS Photodetector Channels Transimpedance Amplifier One bare Silicon, two optically filtered Silicon Channel independent, shielded and temperature stabilized circuit Gain Ranges per TIA Channel 5 GENERAL SPECIFICATIONS Com Port Interface Protocol Interface Connectors & Input Requirements Dimensions FTDI USB UART (virtual) Simple ASCII commands Connects directly to the RS7 light engine via included cables Length 71.5mm (2.82 in), Width 44.5mm (1.75 in), Height x 44.5mm (1.75 in) SpectraLED Family of Tunable Light Sources RS7-1 Benchtop RS7-2 Large Output Port RS7-3 Fiber Optic Output RS7-4 Wafer Probe 75mm output port with integral integrating sphere Exit ports ranging from 150mm to 600 mm One or more fiber outputs with distal end collimation Directly replaces lamp-based systems RS7-5 Baffle Output 150mm output with user adjustable f/number of f/1, f/2, f/3 or f/4 RS7-6 Wide Field of View RS7-7 Light Booth 75mm output port with up to 180 field of view CRI experimentation, analysis & optimization Specifications are subject to change without notice Gamma Scientific, All Rights Reserved Rev Carroll Canyon Rd San Diego, CA

We bring quality to light. MAS 40 Mini-Array Spectrometer

We bring quality to light. MAS 40 Mini-Array Spectrometer MAS 40 Mini-Array Spectrometer Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters Different models

More information

LED Lighting Flux and Color Measurement System (LFC)

LED Lighting Flux and Color Measurement System (LFC) LED Lighting Flux and Color Measurement System (LFC) Fast, accurate and complete System for research and production LFC System is a high cost efficiency light measurement system. The system is designed

More information

ISS-30-VA. Product tags: Integrating Sphere Source. https://www.gigahertz-optik.de/en-us/product/iss-30-va. Gigahertz-Optik GmbH 1/5

ISS-30-VA. Product tags: Integrating Sphere Source. https://www.gigahertz-optik.de/en-us/product/iss-30-va. Gigahertz-Optik GmbH 1/5 ISS-30-VA https://www.gigahertz-optik.de/en-us/product/iss-30-va Product tags: Integrating Sphere Source Gigahertz-Optik GmbH 1/5 Description standards for spectral radiance Spectroradiometers and other

More information

JETI Specbos Instruments

JETI Specbos Instruments Spectral measuring instruments for various applications JETI Specbos Instruments The new Specbos family offers compact, spectrometric instruments, designed to measure the color coordinates, spectral characteristics

More information

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold 1354 MINIS Oriel Integrating Spheres Integrating spheres are ideal optical diffusers; they are used for radiometric measurements where uniform illumination or angular collection is essential, for reflectance

More information

We bring quality to light. CAS 120 CCD Array Spectrometer

We bring quality to light. CAS 120 CCD Array Spectrometer We bring quality to light. CAS 120 CCD Array Spectrometer The features at a glance Precision spectrograph with integrated density filter wheel (OD 1 4) Shutter for automatic dark current correction 2048

More information

AvaLight-DHc Full-range Compact Light Source

AvaLight-DHc Full-range Compact Light Source AvaLight-DHc Full-range Compact Light Source AvaLight-DHc Get the best out of two worlds with the AvaLight-DHc. It has both a deuterium light source and a halogen light source, providing you with adequate

More information

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration Technical Notes Integrating Sphere Measurement Part II: Calibration This Technical Note is Part II in a three part series examining the proper maintenance and use of integrating sphere light measurement

More information

Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions

Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions Combining the Expertise of Two Industry Leaders to Give You An Immense Range of Complete Electro-Optical

More information

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 LM-79-08 Test Report For MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006 Outdoor Wall-Mounted Area Luminaires Model name(s): BLP50AUT550BPCMA BLP50AUT530BPCMA Representative (Tested)

More information

Calibration of a High Dynamic Range, Low Light Level Visible Source

Calibration of a High Dynamic Range, Low Light Level Visible Source Calibration of a High Dynamic Range, Low Light Level Visible Source Joe LaVeigne a, Todd Szarlan a, Nate Radtke a a Santa Barbara Infrared, Inc., 30 S. Calle Cesar Chavez, #D, Santa Barbara, CA 93103 ABSTRACT

More information

OL 730CV Virtual Radiometer/Photometer PC-Controlled Virtual Instrument

OL 730CV Virtual Radiometer/Photometer PC-Controlled Virtual Instrument OL 730CV Virtual Radiometer/Photometer PC-Controlled Virtual Instrument The OL 730CV Virtual Radiometer/ Photometer sets a new standard in economically-priced, research-grade light measurement instrumentation

More information

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D

LM Test Report. For. T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Quality Assured NVLAP LAB CODE 200960-0 LM-79-08 Test Report For EIKO GLOBAL, LLC 23220 W 84th Street, Shawnee, KS 66227 T8 LEDTUBE Model: LED9WT8 F/24/850K-G7D Laboratory: Leading Testing Laboratories

More information

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ LM-79-08 Test Report For Maxlite Inc (Brand Name: ) 12 York Avenue, West Caldwell, NJ 07006 LED Downlight Model name(s): RRECO84040W Test & Report By: Johnson Sun Engineer: Johnson Sun Date: Jun.10,2015

More information

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting. https://www.gigahertz-optik.de/en-us/product/bts256-par

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting. https://www.gigahertz-optik.de/en-us/product/bts256-par BTS256-PAR https://www.gigahertz-optik.de/en-us/product/bts256-par Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting Gigahertz-Optik GmbH 1/8 Description Measurement and examination of

More information

71332 LED Dusk To Dawn (Area Light)

71332 LED Dusk To Dawn (Area Light) 71332 LED Dusk To Dawn (Area Light) 48 QPL ID # PK6ZRDD6 dusk-to-dawn photocell LM-79-08 Test Report For Morris Products Inc. (Brand Name: Morris) 53 Carey Road Queensbury, NY 12804 Outdoor Wall-Mounted

More information

Measuring Spectral Performance of Night Vision Devices

Measuring Spectral Performance of Night Vision Devices Specialized Spectral Measurement Equipment And Techniques Dominate Night Vision Applications Since the inception of night vision equipment in the early 1950s the development of night vision goggles has

More information

Vixar High Power Array Technology

Vixar High Power Array Technology Vixar High Power Array Technology I. Introduction VCSELs arrays emitting power ranging from 50mW to 10W have emerged as an important technology for applications within the consumer, industrial, automotive

More information

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD)

NVLAP LAB CODE LM Test Report. For SHENZHEN BONLD ELECTRONICS CO.,LTD. (Brand Name: BONLD) LM-79-08 Test Report For SHENZHEN BONLD ELECTRONICS CO.,LTD (Brand Name: BONLD) Bldg2-5, TongFuYu Industrial Park, Aiqun Road, Shiyan Town, Bao an District, Shenzhen, China 1x4 Luminaires for Ambient Lighting

More information

Radiometric and Photometric Measurements with TAOS PhotoSensors

Radiometric and Photometric Measurements with TAOS PhotoSensors INTELLIGENT OPTO SENSOR DESIGNER S NUMBER 21 NOTEBOOK Radiometric and Photometric Measurements with TAOS PhotoSensors contributed by Todd Bishop March 12, 2007 ABSTRACT Light Sensing applications use two

More information

G2 High Output Linear Accent

G2 High Output Linear Accent G2 HIGH OUTPUT LINER CCENT High performance cove, graze and wash applications Tunable spectrum single point source produces wide range of white, pastels & saturated colors Closed-loop color point maintenance

More information

Lumen lm 1 lm= 1cd 1sr The luminous flux emitted into unit solid angle (1 sr) by an isotropic point source having a luminous intensity of 1 candela

Lumen lm 1 lm= 1cd 1sr The luminous flux emitted into unit solid angle (1 sr) by an isotropic point source having a luminous intensity of 1 candela WORD BANK Light Measurement Units UNIT Abbreviation Equation Definition Candela cd 1 cd= 1(lm/sr) The SI unit of luminous intensity. One candela is the luminous intensity, in a given direction, of a source

More information

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A 71345A 50W LED Floodlight Yoke(Bracket) Mount RoHS QPL ID # PLDUWHES4P5Q Model: Input Voltage Input Current Input Power Power Factor OVERALL LAMP Luminance PARAMETERS Luminous Efficiency CRI Beam Angle

More information

Photometry and Light Measurement

Photometry and Light Measurement Photometry and Light Measurement Adrian Waltho, Analytik Ltd adrian.waltho@analytik.co.uk What is Light? What is Light? What is Light? Ultraviolet Light UV-C 180-280 nm UV-B 280-315 nm UV-A 315-400 nm

More information

White Paper on SWIR Camera Test The New Swux Unit Austin Richards, FLIR Chris Durell, Joe Jablonski, Labsphere Martin Hübner, Hensoldt.

White Paper on SWIR Camera Test The New Swux Unit Austin Richards, FLIR Chris Durell, Joe Jablonski, Labsphere Martin Hübner, Hensoldt. White Paper on Introduction SWIR imaging technology based on InGaAs sensor products has been a staple of scientific sensing for decades. Large earth observing satellites have used InGaAs imaging sensors

More information

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING) LM-79-08 Test Report For Shenzhen OKT Lighting Co.,LTD (Brand Name: OKT LIGHTING) NO.2076 Jincheng Rd,Shajing Town, Bao'an District, Shenzhen, China. SSL downlight retrofits Model name(s): C10-D54W-XXE

More information

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard Lamp specifics: Luminaire Used: none none Rated Watts Voltage: 6.75 Watts Lamp Type: LPL-W18-120C-930 / 78875 / Rated Orientation CCT: VBD Test Requester E.Z. Cola Rated Voltage 12 V DC New Product: 1

More information

LI-1500 Light Sensor Logger

LI-1500 Light Sensor Logger LI-1500 Light Sensor Logger The LI-1500 Light Sensor Logger provides a direct digital readout and data logging from up to three LI-COR sensors at the same time. Log manually or set up one-time, daily,

More information

UNMATCHED OUTPUT POWER AND TUNING RANGE

UNMATCHED OUTPUT POWER AND TUNING RANGE ARGOS MODEL 2400 SF SERIES TUNABLE SINGLE-FREQUENCY MID-INFRARED SPECTROSCOPIC SOURCE UNMATCHED OUTPUT POWER AND TUNING RANGE One of Lockheed Martin s innovative laser solutions, Argos TM Model 2400 is

More information

Power Sensors Introduction

Power Sensors Introduction Introduction Introduction and Selection Charts & Coherent uses three primary coatings to capture the incident radiation on our thermal sensors. The specifications for each sensor list which coating is

More information

RoHS. Model: VAC 50/60HZ.83A Max 100W

RoHS. Model: VAC 50/60HZ.83A Max 100W Cat# 71542 100 Watts Trunion Mount RoHS UL/CUL TUV-CE QPL ID # PTX2Q1C3 Model: 71542 Input Voltage Input Current Input Power 100-277VAC 50/60HZ.83A Max 100W OVERALL LAMP PARAMETERS LED DRIVER LED Power

More information

Camera Calibration Certificate No: DMC II

Camera Calibration Certificate No: DMC II Calibration DMC II 140-036 Camera Calibration Certificate No: DMC II 140-036 For Midwest Aerial Photography 7535 West Broad St, Galloway, OH 43119 USA Calib_DMCII140-036.docx Document Version 3.0 page

More information

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires LM-79-08 Test Report Outdoor Full-Cutoff Wall-mounted Area Luminaires Model name(s): LWP2-80W Remark:The letter X in the model name stands for CCT as bellow :3=3000K, 4=4000K, 5=5000K; YY stands for mounting

More information

Novel Approach for LED Luminous Intensity Measurement

Novel Approach for LED Luminous Intensity Measurement Novel Approach for LED Luminous Intensity Measurement Ron Rykowski Hubert Kostal, Ph.D. * Radiant Imaging, Inc., 15321 Main Street NE, Duvall, WA, 98019 ABSTRACT Light emitting diodes (LEDs) are being

More information

Test Equipment Solutions Datasheet

Test Equipment Solutions Datasheet Test Equipment Solutions Datasheet Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of quality test & measurement (T&M) equipment. We stock all major equipment types

More information

Camera Calibration Certificate No: DMC II

Camera Calibration Certificate No: DMC II Calibration DMC II 140-005 Camera Calibration Certificate No: DMC II 140-005 For Midwest Aerial Photography 7535 West Broad St, Galloway, OH 43119 USA Calib_DMCII140-005.docx Document Version 3.0 page

More information

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB Cat# 71561 80 Watts Slipfitter Mount Model: 71561 OVERALL LAMP PARAMETERS LED DRIVER LED Input Voltage Input Current Input Power Power Factor Luminance Luminous Efficiency CRI Beam Angle Main Structure

More information

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS Section lll: SM Series ometers SPECTROMETERS SM200 OEM Packaged Fiber Optic CCD SM240 Hand-Held CCD SM241 Near Infrared Enhanced CCD AD300 Back Thinned CCD Tunable, TE Cooled SM300 Fluorencenced/Raman

More information

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER Presented by: January, 2015 1 NFMS THEORY AND OVERVIEW Contents Light and Color Theory Light, Spectral Power Distributions, and

More information

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs. 2D Color Analyzer 8 Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs. Accurately and easily measures the distribution of luminance and chromaticity. Advanced

More information

Camera Calibration Certificate No: DMC II

Camera Calibration Certificate No: DMC II Calibration DMC II 230 015 Camera Calibration Certificate No: DMC II 230 015 For Air Photographics, Inc. 2115 Kelly Island Road MARTINSBURG WV 25405 USA Calib_DMCII230-015_2014.docx Document Version 3.0

More information

Ultraviolet (UV-Index) TOCON Datasheets

Ultraviolet (UV-Index) TOCON Datasheets Ultraviolet (UV-Index) TOCON Datasheets UV photodiode with integrated preamplifier SiC based UV sensors with 0 to 5 V voltage output measures intensities from 1.8pW/cm² up to 18W/cm² 91 Boylston Street,

More information

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION

ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Transverse Distance in Units of Mounting Heights Street Side House Side 2 1 0 1 2 1.5.2 ISOFOOTCANDLE LINES OF HORIZONTAL ILLUMINATION Values based on 25 foot mounting height. 11 1/2 17 7/8 11 0 11 REPORT

More information

Camera Calibration Certificate No: DMC II

Camera Calibration Certificate No: DMC II Calibration DMC II 230 027 Camera Calibration Certificate No: DMC II 230 027 For Peregrine Aerial Surveys, Inc. 103-20200 56 th Ave Langley, BC V3A 8S1 Canada Calib_DMCII230-027.docx Document Version 3.0

More information

Camera Calibration Certificate No: DMC II Aero Photo Europe Investigation

Camera Calibration Certificate No: DMC II Aero Photo Europe Investigation Calibration DMC II 250 030 Camera Calibration Certificate No: DMC II 250 030 For Aero Photo Europe Investigation Aerodrome de Moulins Montbeugny Yzeure Cedex 03401 France Calib_DMCII250-030.docx Document

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03176 PAGE: 1 OF 9 LUMINAIRE: CAST WHITE PAINTED FINNED METAL HEAT SINK,SHEETMETAL JUNCTION BOX AFFIXED TO TOP OF HEATSINK, 1 CIRCUIT BOARD WITH 10 LEDS. LAMPS: TEN WHITE MULTI-CHIP LIGHT

More information

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers Spectrometers HR2000+ Spectrometer User-Configured for Flexibility HR2000+ One of our most popular items, the HR2000+ Spectrometer features a high-resolution optical bench, a powerful 2-MHz analog-to-digital

More information

Camera Calibration Certificate No: DMC IIe

Camera Calibration Certificate No: DMC IIe Calibration DMC IIe 230 23522 Camera Calibration Certificate No: DMC IIe 230 23522 For Richard Crouse & Associates 467 Aviation Way Frederick, MD 21701 USA Calib_DMCIIe230-23522.docx Document Version 3.0

More information

Camera Calibration Certificate No: DMC II

Camera Calibration Certificate No: DMC II Calibration DMC II 230 020 Camera Calibration Certificate No: DMC II 230 020 For MGGP Aero Sp. z o.o. ul. Słowackiego 33-37 33-100 Tarnów Poland Calib_DMCII230-020.docx Document Version 3.0 page 1 of 40

More information

Hyperspectral goes to UAV and thermal

Hyperspectral goes to UAV and thermal Hyperspectral goes to UAV and thermal Timo Hyvärinen, Hannu Holma and Esko Herrala SPECIM, Spectral Imaging Ltd, Finland www.specim.fi Outline Roadmap to more compact, higher performance hyperspectral

More information

Instruction Manual of Luminance and Spectral Radiance Calibrations

Instruction Manual of Luminance and Spectral Radiance Calibrations Aalto University School of Electrical Engineering Metrology Research Institute Jari Hovila Pasi Manninen Tuomas Poikonen Petri Kärhä Instruction Manual of Luminance and Version 2.6 07/12/2015 Page 2 (19)

More information

Characterisation of Photovoltaic Materials and Cells

Characterisation of Photovoltaic Materials and Cells Standard Measurement Services and Prices No. Measurement Description Reference 1 Large area, 0.35-sun biased spectral response (SR) 2 Determination of linearity of spectral response with respect to irradiance

More information

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs. 2D Color Analyzer Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs. Accurately and easily measures the distribution of luminance and chromaticity. The included

More information

e2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions

e2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions e2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions e2v s Onyx family of image sensors is designed for the most demanding outdoor camera and industrial machine vision applications,

More information

10-MHz Adjustable Photoreceivers Models 2051 & 2053

10-MHz Adjustable Photoreceivers Models 2051 & 2053 USER S GUIDE 10-MHz Adjustable Photoreceivers Models 2051 & 2053 2584 Junction Avenue San Jose, CA 95134-1902 USA phone: (408) 919 1500 e-mail: contact@newfocus.com www.newfocus.com Warranty New Focus,

More information

Remote Sensing Calibration Solutions

Remote Sensing Calibration Solutions Remote Sensing Calibration Solutions Cameras, Sensors and Focal Plane Arrays Multispectral and Hyperspectral Imagers Small Satellite Imagers Earth Observation Systems SWIR Band Science and Imaging Reconnaissance

More information

Lecture 2: Image Formation and Cameras

Lecture 2: Image Formation and Cameras #1 Lecture 2: Image Formation and Cameras Saad J Bedros sbedros@umn.edu Last Lecture #2 What is Computer vision: deals with the formation, analysis and interpretation of Images Evolving field in Artificial

More information

Oriel Flood Exposure Sources

Oriel Flood Exposure Sources 218 Oriel Flood Exposure Sources High intensity outputs CALIBRATION SOURCES Highly uniform, large collimated beams Efficient out of band rejection Timed exposures DEUTERIUM SOURCES ARC SOURCES INCANDESCENT

More information

Detector-Filter Combination Series

Detector-Filter Combination Series Detector-Filter Combination Series Planar Diffused Silicon Photodiodes The Detector-Filter combination series incorporates a filter with a photodiode to achieve a tailored spectral response. OSI Optoelectronics

More information

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS 1 picoemerald Two Colors in One Box Microscopy and Spectroscopy with a Tunable Two-Color Source CARS and SRS microscopy

More information

Optical Spectrum Analyzers

Optical Spectrum Analyzers Optical Spectrum Analyzers Broadband Spectrometer and Wavelength Meter in One Thorlabs Optical Spectrum Analyzers obtain highly accurate measurements of the spectra of unknown light sources. They are continuously

More information

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e - Apogee Alta Series System Features 1 High Resolution Sensor 1.0 Megapixel sensor with 13 mm pixels delivers a large field of view with high resolution. Programmable TE cooling down to 50 o C below ambient

More information

A Spectral Database of Commonly Used Cine Lighting Andreas Karge, Jan Fröhlich, Bernd Eberhardt Stuttgart Media University

A Spectral Database of Commonly Used Cine Lighting Andreas Karge, Jan Fröhlich, Bernd Eberhardt Stuttgart Media University A Spectral Database of Commonly Used Cine Lighting Andreas Karge, Jan Fröhlich, Bernd Eberhardt Stuttgart Media University Slide 1 Outline Motivation: Why there is a need of a spectral database of cine

More information

A collection of hyperspectral images for imaging systems research Torbjørn Skauli a,b, Joyce Farrell *a

A collection of hyperspectral images for imaging systems research Torbjørn Skauli a,b, Joyce Farrell *a A collection of hyperspectral images for imaging systems research Torbjørn Skauli a,b, Joyce Farrell *a a Stanford Center for Image Systems Engineering, Stanford CA, USA; b Norwegian Defence Research Establishment,

More information

IESNA standards on LED and SSL: LM-79, LM-80, and future standards

IESNA standards on LED and SSL: LM-79, LM-80, and future standards CORM 2009 Conference, Gaithersburg, MD, May 6-8, 2009 IESNA standards on LED and SSL: LM-79, LM-80, and future standards Yoshi Ohno Director of CIE Division 2 Member of ANSI C78-09, IESNA TPC National

More information

Checked X.CAO

Checked X.CAO REPORT NUMBER: RAB02068 PAGE: 1 OF 7 CATALOG NUMBER: FXLED78SF - FXLED78T (SF=SLIPFITTER MOUNT & T=TRUNNION MOUNT) LUMINAIRE: CAST FINNED METAL HOUSING, MOLDED PLASTIC REFLECTOR WITH SPECULAR FINISH AND

More information

Lab Junior Educational UV-VIS Spectrometer

Lab Junior Educational UV-VIS Spectrometer www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +1.847.913.0777 for Refurbished & Certified Lab Equipment Lab Junior Educational UV-VIS Spectrometer K-MAC Lab Junior was developed

More information

MUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM

MUSKY: Multispectral UV Sky camera. Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM MUSKY: Multispectral UV Sky camera Valentina Caricato, Andrea Egidi, Marco Pisani and Massimo Zucco, INRIM Outline Purpose of the instrument Required specs Hyperspectral or multispectral? Optical design

More information

LENS ZOOM-SWIR 7x P/N C0628

LENS ZOOM-SWIR 7x P/N C0628 ZOOM SWIR 7x LENS ZOOM-SWIR 7x P/N C0628 General Description This family of high resolution SWIR lenses image from 0.9 2.3 m making them especially well-suited for PCB inspection, special laser applications,

More information

Signal-to-Noise Ratio (SNR) discussion

Signal-to-Noise Ratio (SNR) discussion Signal-to-Noise Ratio (SNR) discussion The signal-to-noise ratio (SNR) is a commonly requested parameter for hyperspectral imagers. This note is written to provide a description of the factors that affect

More information

Metis H311 / H322. Highly Advanced, Full Featured 2-Color High-Speed Pyrometers

Metis H311 / H322. Highly Advanced, Full Featured 2-Color High-Speed Pyrometers Metis H311 / H322 Highly Advanced, Full Featured 2-Color High-Speed Pyrometers High-Speed 2-color pyrometer for non-contact temperature measurement in short wavelength spectral range, primarily for measurements

More information

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent 83440B/C/D High-Speed Lightwave Converters Agilent 8344B/C/D High-Speed Lightwave Converters DC-6/2/3 GHz, to 6 nm Technical Specifications Fast optical detector for characterizing lightwave signals Fast 5, 22, or 73 ps full-width half-max (FWHM)

More information

APE Autocorrelator Product Family

APE Autocorrelator Product Family APE Autocorrelator Product Family APE Autocorrelators The autocorrelator product family by APE includes a variety of impressive features and properties, designed to cater for a wide range of ultrafast

More information

Digital Image Processing

Digital Image Processing Digital Image Processing Lecture # 3 Digital Image Fundamentals ALI JAVED Lecturer SOFTWARE ENGINEERING DEPARTMENT U.E.T TAXILA Email:: ali.javed@uettaxila.edu.pk Office Room #:: 7 Presentation Outline

More information

ULISSE COMPACT THERMAL

ULISSE COMPACT THERMAL 2014/01/20 UNIT WITH INTEGRATED THERMAL AND DAY/NIGHT CAMERAS MAIN FEATURES Variable speed: 0.1-200 /s Pan/Tilt Horizontal continuous rotation, vertical -90 /+90 IP66 Dual independent video output Complete

More information

LTE. Tester of laser range finders. Integrator Target slider. Transmitter channel. Receiver channel. Target slider Attenuator 2

LTE. Tester of laser range finders. Integrator Target slider. Transmitter channel. Receiver channel. Target slider Attenuator 2 a) b) External Attenuators Transmitter LRF Receiver Transmitter channel Receiver channel Integrator Target slider Target slider Attenuator 2 Attenuator 1 Detector Light source Pulse gene rator Fiber attenuator

More information

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography

PicoMaster 100. Unprecedented finesse in creating 3D micro structures. UV direct laser writer for maskless lithography UV direct laser writer for maskless lithography Unprecedented finesse in creating 3D micro structures Highest resolution in the market utilizing a 405 nm diode laser Structures as small as 300 nm 375 nm

More information

UV-Index Photodiodes Data Sheets

UV-Index Photodiodes Data Sheets UV-Index Photodiodes Data Sheets For UV-Index measurement according ot CIE087, 3 % error only = most precise currently available detector, cosine corrected, different packagings, sorted by detector areas.

More information

30 x 3.8 mm / 2000 x 256 pixel NIR Spectroscopy CCD. cooling. Specifications Summary. Active pixels 2000 x 256

30 x 3.8 mm / 2000 x 256 pixel NIR Spectroscopy CCD. cooling. Specifications Summary. Active pixels 2000 x 256 Quantum efficiency (%) 1 9 8 7 6 5 4 3 Absorption Photoluminescence 532 nm Raman New Low Noise Back-illuminated Deep-Depletion Technology Spectroscopy 633 nm Raman 2 785 nm Raman 1 83 nm Raman 2 3 4 5

More information

Zenith Polymer Diffuse Reflectance Standards, Targets and Materials. ... your Partner in Lighting Technology!

Zenith Polymer Diffuse Reflectance Standards, Targets and Materials. ... your Partner in Lighting Technology! Zenith Polymer Diffuse Reflectance Standards, Targets and Materials For use over the UV, VIS and NIR spectral regions... your Partner in Lighting Technology! Properties of Zenith Polymer optical PTFE All

More information

Spark Spectral Sensor Offers Advantages

Spark Spectral Sensor Offers Advantages 04/08/2015 Spark Spectral Sensor Offers Advantages Spark is a small spectral sensor from Ocean Optics that bridges the spectral measurement gap between filter-based devices such as RGB color sensors and

More information

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR

IESNA LM-79: Measurement and Test Report for EiKO Global, LLC. Sep 09, 2013 LED8WMR16/38/830-DIM. David Zhang BTR IESNA LM-79: 2008 Measurement and Test Report for EiKO Global, LLC Sep 09, 2013 Product Name: LED Model No: LED8WMR16/38/830-DIM Test Engineer: David Zhang Report No.: BTR66.181.13.1294.01-1 Sample Received

More information

Peltier Cooled Thermal Management System User s Guide

Peltier Cooled Thermal Management System User s Guide Peltier Cooled Thermal Management System User s Guide For use with StellaCam II, StellaCam3 and Wat-120N astro-video cameras Developed and maintained by CosmoLogic Systems, Inc. Thank you for purchasing

More information

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES S. Roose (1), Y. Stockman (1), Z. Sodnik (2) (1) Centre Spatial de Liège, Belgium (2) European Space Agency - ESA/ESTEC slide 1 Outline

More information

A Light Source for Testing CMOS Imagers

A Light Source for Testing CMOS Imagers A Light Source for Testing CMOS Imagers Jed 1. Hancock Department of Electrical and Computer Engineering Utah State University Logan, Utah 84322 Abstract Testing the optical properties of complementaiy

More information

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: MLFP24DS4241/SD Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.6 4723.5 43.49 0.9902 CCT (K) CRI Stabilization Time (Light & Power)

More information

Method for Quantifying the Spectral Based Error in Luminance Measurements

Method for Quantifying the Spectral Based Error in Luminance Measurements University of Colorado, Boulder CU Scholar Civil Engineering Graduate Theses & Dissertations Civil, Environmental, and Architectural Engineering Spring 1-1-2017 Method for Quantifying the Spectral Based

More information

Light Emitting Diode Illuminators for Video Microscopy and Machine Vision Applications

Light Emitting Diode Illuminators for Video Microscopy and Machine Vision Applications Light Emitting Diode Illuminators for Video Microscopy and Machine Vision Applications By Dr. Dmitry Gorelik, Director of Research and Development, Navitar, Inc. Illumination system as the part of an imaging

More information

What Makes Push-broom Hyperspectral Imaging Advantageous for Art Applications. Timo Hyvärinen SPECIM, Spectral Imaging Ltd Oulu Finland

What Makes Push-broom Hyperspectral Imaging Advantageous for Art Applications. Timo Hyvärinen SPECIM, Spectral Imaging Ltd Oulu Finland What Makes Push-broom Hyperspectral Imaging Advantageous for Art Applications Timo Hyvärinen SPECIM, Spectral Imaging Ltd Oulu Finland www.specim.fi Outline What is hyperspectral imaging? Hyperspectral

More information

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras Geospatial Systems, Inc (GSI) MS 3100/4100 Series 3-CCD cameras utilize a color-separating prism to split broadband light entering

More information

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI Test Summary Sample Tested: FLS50U50B Luminous Efficacy (Lumens /Watt) Total Luminous Flux (Lumens) Power (Watts) Power Factor 108.1 5291.8 48.96 0.9859 CCT (K) CRI Stabilization Time (Light & Power) 5119

More information

UV-Index Photodiodes Data Sheets

UV-Index Photodiodes Data Sheets UV-Index Photodiodes Data Sheets For UV-Index measurement according ot CIE087, 3 % error only = most precise currently available detector, cosine corrected, different packagings, sorted by detector areas.

More information

SOAR Integral Field Spectrograph (SIFS): Call for Science Verification Proposals

SOAR Integral Field Spectrograph (SIFS): Call for Science Verification Proposals Published on SOAR (http://www.ctio.noao.edu/soar) Home > SOAR Integral Field Spectrograph (SIFS): Call for Science Verification Proposals SOAR Integral Field Spectrograph (SIFS): Call for Science Verification

More information

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Rotation By: Michael Case and Roy Grayzel, Acton Research Corporation Introduction The majority of modern spectrographs and scanning

More information

Systems & Accessories

Systems & Accessories Light Source Sample Chambers Stepping Motor Controller Detector Variable Wavelength Fiber Optics Modules Tunable Light Sources For Applications In: Analytical Chemistry Physics Life Sciences Engineering

More information

Coating Thickness Measurement System

Coating Thickness Measurement System Spectral Sensors by Carl Zeiss Coating Thickness Measurement System INTRODUCTION Designed to meet the needs of industry, the LABCOAT system provides a simple and precise way to measure transparent coatings

More information

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note Technical Note CMOS, EMCCD AND CCD CAMERAS FOR LIFE SCIENCES Camera Test Protocol Introduction The detector is one of the most important components of any microscope system. Accurate detector readings

More information

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker AR111 12.5W OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES BEAM ANGLE RANGE COLOR TEMPERATURE RANGE APPLICATION 5-6 lumen 735-795 lumen 8,, 36, 27K, 3K, 4K, K Halogen replacement for indoor

More information

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT

Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT Takeshi Fujiwara 1, Yuki Mitsuya 2, Hiroyuki Takahashi 2, and Hiroyuki Toyokawa 2 1 National Institute of Advanced Industrial

More information