OL Series 426 Low Light Level lntegrating Sphere Calibration Standards

Size: px
Start display at page:

Download "OL Series 426 Low Light Level lntegrating Sphere Calibration Standards"

Transcription

1 OL Series 426 Low Light Level lntegrating Sphere Calibration Standards GENERAL The OL Series 426 Low-Light-Level Calibration Standard is designed for accurately calibrating very sensitive microphotometers, image intensifiers, telephotometers, and imaging spectroradiometers for photometric or spectroradiometric response at moderate to extremely low light levels. It serves as a highly accurate, large area, uniform, diffusely radiating source with a near normal luminance that can be varied over nearly 6 decades with essentially constant color temperature. The OL Series 426 consists of an Optics Head and a separate electronic display console/power supply (OL 400-C Controller). This enables remote location of either unit, which facilitates alignment or positioning of the source with respect to the device to be calibrated. The source module/optics head is designed such that it can be configured with integrating spheres having diameters of 4, 6, 8, 12 and 18 inches with exit (radiating) ports of 1, 1½, 2, 3 and 6 inches, respectively. OPTICS HEAD The OL 426 is based on a dual integrating sphere design, with the arrangement of these spheres in series. The exit port of the first sphere, or primary sphere, produces a uniform beam into the entrance port of the secondary sphere. A baffle tube connects the exit port of the primary sphere to the entrance port of the secondary sphere, and an aperture in the baffle tube determines how much light is allowed into the secondary sphere, thus the maximum luminance at the radiating port can range over several decades depending on the size of the aperture installed. The aperture is not used to determine the true luminance at the exit port of the secondary sphere but merely scale it by the desired amount. A precision silicon detector-filter combination with an accurate photopic response mounted in the wall of the primary sphere tracks the luminance in the primary sphere at higher levels for accuracy purposes, and the luminance display is scaled to indicate the actual luminance at the exit port of the secondary sphere. The actual luminance of the exit port is calibrated via measurements, and then the monitor detector gain is scaled appropriately. The in-line sphere port concept with an intermediate spider baffle provides exceptional uniformity in the near normal luminance across the radiating port. A shutter is located between the lamp and the entrance port of the primary sphere. The luminance/ radiance output can be switched between zero and any desired level without adjustment or lamp changes. An optional filter holder, mounted at the exit port, accommodates alignment targets, filters, de-coupling diffusers etc. for specific user requirements. Spectral shaping filters can be utilized to simulate various sources such as Illuminate A, B, C, D65, etc. In addition to luminance and color temperature, the OL Series 426 can be obtained with calibrations for spectral radiance over the 350 to 1100 nm wavelength range. CONTROLLER The microprocessor-based OL 400-C Controller performs all system interface and monitoring functions. An automatic ramp up/down function eliminates potentially dangerous current surges to the lamp. Luminance, color temperature, and lamp current are displayed on a 2 line by 20 character alphanumeric LED display, which may be turned off for low-light level conditions. An 8-key keypad and main power switch are located on the front panel for easy access to all system functions. Luminance is displayed with 4 ½ digits plus exponent in units specified by the user. As an option, the display can be factory programmed to read in virtually any pertinent units the user desires. DC current supplied to the lamp has a ampere resolution with a 0.02% uncertainty. The controller computes the color temperature of the source over the range of K. Software for remote operation of the source is provided, allowing control of lamp on/off functions and setting the lamp current (color temperature) as well as readout of the photometer in any preprogrammed optical unit. An optional software development kit is available for custom programming. Bulletin 136 / Rev 7-11 Page 1 of 2

2 OL Series 426 Low Light Level Integrating Sphere Calibration Standards OL 426-OH OPTICS HEAD Luminance Uncertainty (k=2)... ± 2% (2300 K to 2900 K (± 50K)) 2 ± 2.0% to ± 3.5% (2000 K to 2300 K) Spectral Radiance Calibration optional (relative to NIST)... ± 2% to ± 3%, nm Correlated Color Temperature Range to 2950 K (± 50 K) Correlated Color Temperature Uncertainty (k=2)... Less than ± 25 K Luminance 2856 K Short Term... ± 0.5% (after 15 minutes warm-up) Long Term... ± 2% 100 hours of use or 1 year Spectral Radiance 550 nm... ± 2% relative to NIST Sphere Coating (reflectance)... > 99% (350 to 1100 nm) Variable Aperture... Micrometer-controlled Shutter... Open/ Closed OL 400-C CONTROLLER Current Source Luminance Display Range A Resolution A Accuracy % of full-scale Stability ppm after warm-up Line Voltage Sensitivity... < 2 ppm/ V Temperature Sensitivity... < 25 ppm / C Photometer Ranges... 2E-10 to 2E-3 A Resolution... 4½ digits ( E-x A) Accuracy E-3 to E-7 ranges % ± 1 digit E-8 to E-9 ranges % ± 1 digit E-10 ranges % ± 2 digit Range Selector... auto, manual, or software-selectable Response Time to 10 seconds Physical Size in D x 9.38 in W x 5.38 in H (30.48 cm x cm x cm) Weight pounds (7.7 kg) Power Input /115/230 VAC, 3.2/3.2/2 A, 50/60 Hz Operating Temperature Range to 35 C Operating Humidity Range... 10% to 85% (non-condensing) Model Number Sphere Exit Port LUMINANCE LEVELS (nominal) Uniformity Maximum K Display Resolution OL ±1.0% 80 fl 130 fl 1 E-7 fl OL ½ ±1.0% 40 fl 70 fl 1 E-7 fl OL ±1.0% 29 fl 40 fl 1 E-7 fl OL ±1.0% 14 fl 23 fl 1 E-7 fl OL ±2.0% 4 fl 7 fl 1 E-7 fl Other configurations available upon request. OL SERIES 426 SPECIFICATIONS CALIBRATION OPTIONS OL 426-X-... luminance, color temperature OL 426-X-1... luminance, color temperature, 1/ spectral radiance (350 to 1100 nm) OL 426-X-U... uncalibrated * Note: "X" designates the diameter of the integrating sphere. 1/ Spectral radiance measured at a color temperature of ~3000K unless otherwise specified. Bulletin 136 / Rev 7-11 Page 2 of 2

3 OL OH Variable Ultraviolet Integrating Sphere Calibration Standard The OL OH Variable Ultraviolet Integrating Sphere Calibration Standard is large area, uniform, diffusely radiating source with a near normal integrated radiance that can be varied over several decades. The OL OH consists of a forced air cooled source housing incorporating a deuterium lamp that is coupled to an 8-inch diameter integrating sphere coated with pressed PTFE. A micrometer-controlled aperture between the lamp and the 1-inch diameter input port of the integrating sphere allows continuous adjustment of the sphere intensity over the full useful range. The in-line sphere port concept with an intermediate spider baffle provides for uniformity across the radiating aperture. A precision UV-enhanced silicon detector is mounted in the sphere wall and monitors the source intensity. An external radiometer, such as the OL 730C Programmable Radiometer/Photometer or equivalent, is utilized for readout of the integrated source radiance by measurement of the monitor detector current. A shutter, located between the lamp and the entrance port of the integrating sphere, allows zeroing out the monitor detector without removing power to the lamp. The location of the shutter also ensures that any stray light (room light) entering the exit (radiating) port of the sphere is properly accounted for when zeroing the monitor detector. The sphere s exit (radiating) port has a 2.0-inch (50.8-mm) diameter aperture opening. The OL OH is provided with a spectral radiance calibration over the 200 nm to 400 nm region. The source is also available without calibration. OL OH Variable Ultraviolet Integrating Sphere Calibration Standard top view Bulletin 79 / Rev 7-11 Page 1 of 2

4 OL OH Variable Ultraviolet Integrating Sphere Calibration Standard OL OH Optics Head Specifications Lamp Type Deuterium...(30-watt) Operating Current milliamperes DC Spectral Radiance Uncertainty (relative to NIST, k=2)... ± 3% to 10% ( nm) ± 20% ( nm) Output Uniformity... ± 5% (1 inch dia) 1 ± 15% (full port) 1 Monitor Stability... ± 1% (after 30 minutes warm-up) Sphere Coating (reflectance) % ( nm) Sphere Monitor (built-in)... UV-Enhanced Silicon Detector Starting Voltage VDC (min.) Anode Voltage V ± 10% Filament Starting Voltage VDC (1.2 A) Filament Operating Voltage... 7 VDC (1.0 A) Filament Prestart Warm-up Time seconds Optional Accessories... OL 46D Deuterium Lamp Power Supply 2 1/ Uniformity values are relative to the deviation from the average value of the points measured over the diameter specified. 2 / Requires modification of the OL 46D Power Supply to include an additional connector on the rear panel that supplies power to the 12 VDC fan in the OL H. OL OH Variable Ultraviolet Integrating Sphere Calibration Standard side view Bulletin 79 / Rev 7-11 Page 2 of 2

5 OL Series 454 Integrating Sphere Source The variable aperture can be used to attenuate the output of the sphere source over a range of up to six decades. General The OL Series 454 Integrating Sphere Source is designed to produce a high intensity Lambertian distribution. It is useful as a highly uniform illumination source for contrast measurements, linearity tests, flat-fielding of devices for response uniformity, and device MTF with the optional filter holder and the desired resolution target. It consists of an OL Series 454 Optics Head and a separate OL Precision Lamp Source. The source is also available with a color temperature calibration over the K range. The source module/optics head is designed such that it can be configured with integrating spheres having diameters of 4, 6, 8, 12 and 18 inches with exit (radiating) ports of 1, 1½, 2, 3 and 6 inches, respectively. Source Module/Optics Head The Source Module/Optics Head uses a 150-W tungsten-halogen reflectorized lamp with a micrometer-controlled variable aperture between the lamp and the integrating sphere. The sphere has a highly reflective, diffuse reflecting PTFE based coating. The in-line sphere port geometry, with an intermediate spider baffle in the middle of the sphere, provides for exceptional uniformity in the near normal luminance over the entire radiating port of the sphere. A shutter is located between the lamp and the entrance port of the sphere. An optional filter holder, mounted at the exit port, accommodates alignment targets, filters, de-coupling diffusers etc. for specific user requirements. Spectral shaping filters can be utilized to simulate various sources such as illuminates A, B, C, D65, etc. Controller The OL is a highly regulated constant current DC power supply that optimizes source stability and accuracy. The lamp current is displayed to 4 digits on the digital display and can be adjusted. The uncertainty in the current setting is ± 0.02%. In order to enhance the stability and life of the lamp, a current ramp up/ramp down circuit is employed which prevents thermal shock to the lamp. Lamp usage hours are recorded internally and can be viewed in the digital display to accurately monitor the calibration life of the source. In addition, an automatic shut down circuit is employed that turns off the unit in case of excessive current due to system malfunction or accidental setting of too high a lamp current by the user. Bulletin 137 / Rev 9-11 Page 1 of 2

6 OL Series 454 Integrating Sphere Source OL 454-OH OPTICS HEAD Correlated Color Temperature Range to 3000 K Correlated Color Temperature Uncertainty... ± 25 K Luminance 2856 K Short Term... ± 1.0% (after 15 minute warm-up) Long Term... ± 3% 50 hours/ 1 year Sphere Coating (reflectance)... > 99% (350 to 1100 nm) Shutter... Open/ Closed OL CONTROLLER Current Display (4 digits)... Amperes Current Adjustment Range... 0 to 6.5 amperes DC Current Accuracy (amps DC)... ± 0.02% (4 digits) Current Regulation (amps DC)... ± 0.01% for 10% line variation Lamp Power Cycle... controlled ramp function Current Temperature Regulation... ± 0.025% / 10 C Operating Temperature Range...15 to 35 C Operating Humidity Range... 10% to 85% (non-condensing) Elapsed Time Meter... 0 to hours Power (user selectable) /115/230 VAC ± 10%, 50/60 Hz Model Number Sphere LUMINANCE LEVELS (nominal) Exit Port 2856 K Maximum 3000 K OL ± 1.0% fl fl OL ½ ± 1.0% fl fl OL ± 1.0% 9000 fl fl OL ± 1.0% 4000 fl 6400 fl OL ± 2.0% 700 fl 1100 fl Other configurations available upon request. OL SERIES 454 SPECIFICATIONS CALIBRATION OPTIONS OL 454-X-K... color temperature ( K) OL 454-X-U... uncalibrated * Note: "X" designates the diameter of the integrating sphere. Bulletin 137 / Rev 9-11 Page 2 of 2

7 OL Series 455 Integrating Sphere Calibration Standard GENERAL The OL Series 455 Integrating Sphere Calibration Standard is designed for accurately calibrating microphotometers, image intensifiers, telephotometers and imaging spectroradiometers for photometric, radiometric, or spectroradiometric response. It serves as a highly accurate, large area, uniform, diffusely radiating source with a near normal luminance that can be varied over 6 decades with essentially constant color temperature. The OL Series 455 consists of an optics head and a separate electronic display console/ power supply (OL 400- C Controller). This enables remote location of either unit, which facilitates alignment or positioning of the source with respect to the device to be calibrated. The source module/ optics head is designed such that it can be configured with integrating spheres having diameters of 4, 6, 8, 12 and 18 inches with exit (radiating) ports of 1, 1½, 2, 3 and 6 inches, respectively. OPTICS HEAD The optics head has a 150-W tungsten-halogen reflectorized lamp with a micrometer-controlled variable aperture between the lamp and the entrance port of the integrating sphere. This combination provides for continuous adjustment of the sphere luminance over a range of more than A precision silicon detector-filter combination with an accurate photopic response is mounted in the sphere wall and monitors the sphere luminance. The in-line sphere port concept with an intermediate spider baffle provides exceptional high luminance levels while maintaining high uniformity in the near normal luminance across the radiating aperture. A shutter is located between the lamp and the entrance port of the integrating sphere. The location of the shutter ensures that any stray light (room light) entering the radiating port of the sphere is properly accounted for when auto-zeroing the photometer. In addition, the source output can easily be set to zero by use of the shutter without any changes to the sphere luminance setting. An optional filter holder, mounted at the exit port, accommodates alignment targets, filters, de-coupling diffusers etc. for specific user requirements. Spectral shaping filters can be utilized to simulate various sources such as Illuminant A, B, C, D65, etc. In addition to luminance and color temperature, the OL Series 455 can be obtained with calibrations for spectral radiance over all or part of the entire 350 to 2500 nm wavelength range. CONTROLLER The microprocessor-based OL 400-C Controller performs all system interface and monitoring functions. An automatic ramp up/ down function eliminates potentially dangerous current surges to the lamp. Luminance, color temperature, and lamp current are displayed on a 2 line by 20 character alphanumeric LED display, which may be turned off for lowlight level conditions. An 8 key keypad and main power switch are located on the front panel for easy access to all system functions. Luminance is displayed with 4 ½ digits plus exponent in units specified by the user. As an option, the display can be factory programmed to read in virtually any pertinent units the user desires. DC current supplied to the lamp has a ampere resolution with a 0.02% uncertainty. The controller computes the color temperature of the source over the range of K. Software for remote operation of the source including on/off and lamp current setting functions, as well as the photometer read-out units via full speed USB 2.0 interface, is included. An optional software development kit is available for custom programming. OL NVG In order to help you ensure compliance with Appendix 30 of MIL-L-85762A and MIL-STD-3009 requirements we offer the NVG version of the OL for calibration of your NVIS compliance spectroradiometer. The NVG version of the OL 455 is calibrated at 100 fl/2856k for spectral radiance whereas the non-nvg version is calibrated at 90% max/ 3000K for spectral radiance. The luminance cal for both is done at 2856K, but the NVG is done at 100 fl and the non-nvg is done at 90% max. Bulletin 108 / Rev 7-11 Page 1 of 2

8 OL Series 455 Integrating Sphere Calibration Standard OL 455-OH OPTICS HEAD Luminance Uncertainty 2856 K, 90% max. luminance)... ± 0.5% relative to NIST Color Temperature Range to 3000 K Color Temperature Uncertainty... ± 25 K Luminance 2856 K Short Term... ± 0.5% Long Term... ± 2% 100 hours/ 1 year Spectral Radiance 550 nm... ± 2% relative to NIST Sphere Coating (reflectance)... > 99% (350 to 1100 nm) Variable Aperture... micrometer controlled Shutter... open/ closed OL 400-C CONTROLLER Luminance Display (4½ digits)... fl or cd/m 2 Luminance Display Range to 50,000 fl (auto-ranging, manual, or software selectable) Lamp Current Display... 4 digits Range... 0 to amperes DC Power Cycle second ramp function Accuracy... ± 0.02% of full scale Regulation... < 2ppm/ V Temperature Regulation... <25 ppm/ C Lamp Timer >1000 hours Operating Temperature Range to 35 C Operating Humidity Range... 10% to 85% (non-condensing) Power (user selectable) / 115/ 230 VAC, 50/60 Hz Remote Interface... Full-speed USB and TTL-I/O Size x 9.38 x 5.38 Weight lbs. Model Number Sphere Exit Port LUMINANCE LEVELS (nominal) Uniformity Maximum K Display Resolution OL " 1" ± 1.0% 22,000 fl 35,000 fl fl OL " 1½" ± 1.0% 12,000 fl 20,000 fl fl OL " 2" ± 1.0% 9,000 fl 13,000 fl fl OL " 3" ± 1.0% 4,000 fl 6,400 fl fl OL " 6" ± 2.0% 700 fl 1,100 fl fl Other configurations available upon request. CALIBRATION OPTIONS OL 455-X... luminance, color temperature OL 455-X-1... luminance, color temperature, 1/ spectral radiance (350 to 1100 nm) OL 455-X-2... luminance, color temperature, 1/ spectral radiance (350 to 2500 nm) OL 455-X-U... uncalibrated Note: "X" designates the diameter of the integrating sphere. 1/ Spectral radiance measured at a color temperature of ~3000 K unless otherwise specified. Bulletin 108 / Rev 7-11 Page 2 of 2

9 OL 457 LED Integrating Sphere Calibration Standard The OL 457 LED Integrating Sphere Calibration Standard is a cost-effective, wavelength-selectable, nearly monochromatic NIST-traceable radiant light source. It provides more flexibility and higher performance than filtered sources and is a significantly lower cost alternative to monochromators. Typical applications include anywhere a stable or calibrated source is required, e.g. MTF, radiance and irradiance sensitivity of detectors, arrays and cameras, linearity testing, dynamic range testing, signal-to-noise testing etc. Interchangeable LED sources offer more versatility, affording users with an unprecedented level of uniformity and accurate continuously variable intensity over many decades. The interchangeable LED modules are easily installed and removed from the optics head without affecting calibration accuracy. These fully integrated source and heat sink assemblies offer long life and high thermal efficiency for increased stability and output. The OL 457 consists of an optics head and a separate precision constant current source (OL 401-C Controller). This enables remote location of either unit, which facilitates alignment or positioning of the source with respect to the device to be calibrated. The source module/ optics head is designed such that it can be configured with integrating spheres having diameters of 4, 6, 8, 12, and 18 inches. The OL 401-C Calibration Standard Controller automatically recognizes installed LED modules and provides the appropriate precision current to the LEDs, readout of LED current, amplification of the detector signal, and readout of the radiance. OL 457-X LED Modules Peak Nominal Max. Output * Min. Output wavelength HBW (nm) (nm) W/(sr m 2 ) Cd/m 2 W/(sr m 2 ) Cd/m 2 LED-375 (UVA) 375 ± 5 10 ± 5 8 N/A N/A LED-405 (Violet) 405 ± 6 16 ± LED-465 (Blue) 465 ± ± , LED-520 (Green) 520 ± ± , LED-595 (Amber) 595 ± 5 15 ± , LED-630 (Red) 630 ± ± , LED-870 (NIR) 870 ± ± N/A N/A *For 6 inch sphere (OL source). Use the multipliers in the table below to calculate max. output for other sphere sizes OL OL OL OL OL Bulletin 120 / Rev 1-08 Page 1 of 2

10 OL 457 LED Integrating Sphere Calibration Standard All LED modules are calibrated with the sphere in W/(sr m2) unless otherwise requested OL 457-OH OPTICS HEAD Radiance Uncertainty... ± 2% relative to NIST Source Stability Short Term... ± 0.5% Long Term... ± 2% 100 hours/ 1 year Sphere Coating (reflectance) % (350 to 1100 nm) Variable Aperture... micrometer-controlled Shutter... open/ closed OL 401-C Controller Radiance Display (4½ digits)... W/(sr m 2 ) Radiance Display Range to 50,000 W/(sr m 2 ) (auto-ranging, manual, or software selectable) Lamp Current Display... 4 digits Range... 0 to 3.3 amperes DC Power Cycle sec ramp function Accuracy... ± 0.02% of full scale Regulation... 2ppm/V Temperature Regulation... 25ppm/ C Lamp Timer >1000 hours Operating Temperature Range to 35 C Operating Humidity range... 10% to 85% (non-condensing) Power (user selectable) /240 VAC Remote Interface... Full-speed USB and TTL-I/O Size x 9.38 x 5.38 Weight pounds Bulletin 120 / Rev 1-08 Page 2 of 2

11 OL Series 462 Automated Integrating Sphere Calibration Standard GENERAL The OL Series 462 Automated Integrating Sphere Calibration Standard is designed for accurately calibrating instruments such as microphotometers, telephotometers, image intensifiers, and imaging spectroradiometers for photometric, radiometric, or spectroradiometric response. It serves as a highly accurate, large area, uniform, diffusely radiating source with a near normal luminance that can be varied over six decades with essentially constant color temperature. The OL Series 462 consists of an optics head and a separate microprocessor controlled luminance display/ lamp power supply/motor controller console (OL 462-C Controller). This enables remote location of either unit, which facilitates alignment or positioning of the source with respect to the device to be calibrated. The source module/ optics head is designed such that it can be configured with integrating spheres having diameters of 4, 6, 8, 12, and 18 inches with exit (radiating) ports of 1, 1½, 2, 3, and 6 inches, respectively. OPTICS HEAD The optics head has a 150-W tungsten-halogen, reflectorized lamp with a motorized, computer-controlled variable aperture between the lamp and the entrance port of the integrating sphere. This combination provides for continuous adjustment of the sphere luminance over a range of more than A precision silicon detector/ filter combination with an accurate photopic response is mounted in the sphere wall and monitors the sphere luminance. The in-line sphere port concept with an intermediate spider baffle provides exceptional high luminance levels while maintaining high uniformity in the near normal luminance across the radiating aperture. A motorized, computer-controlled shutter is located between the lamp and the entrance port of the integrating sphere. The luminance/ radiance output can be switched between zero and any desired level without adjustment or lamp changes. An optional filter holder, mounted at the exit port, accommodates alignment targets, filters, de-coupling diffusers etc. for specific user requirements. Spectral shaping filters can be utilized to simulate various sources such as illuminates A, B, C, D65, etc. In addition to luminance and color temperature, the OL Series 462 can be obtained with calibrations for spectral radiance over all or part of the 350 to 2500 nm wavelength range. CONTROLLER The microprocessor-based OL 462 Controller performs all the system interface and monitoring functions. An automatic ramp up/ down function eliminates potentially dangerous current surges to the lamp. Luminance, color temperature, lamp current, and operational prompts are displayed on a two line by 20 character alphanumeric vacuum-fluorescent display. A 20 key keypad, rotary encoder knob, and main system power switch are also located on the front panel for easy access to all system functions. Luminance is displayed with five digit resolution in units specified by the user. As an option, the display can be factory programmed to read in virtually any pertinent units the user desires. DC current supplied to the lamp has a ampere resolution with a 0.05% uncertainty. The controller computes the color temperature of the source and displays lamp current or color temperature over the range of 2000 to 3000K. The luminance, color temperature, and lamp current can also be set by an external computer via the standard RS-232C interface. RS-422 and GPIB (IEEE-488) interfaces are also available. An internal microprocessor controlled elapsed time meter enables the user to keep track of the number of hours the lamp has been in operation. Bulletin 119 / Rev 7-11 Page 1 of 2

12 OL Series 462 Automated Integrating Sphere Calibration Standard OL 462-OH OPTICS HEAD Luminance Uncertainty 2856K, 90% max luminance)... ± 0.5% relative to NIST Color Temperature Range to 3000 K Color Temperature Uncertainty... ±25 K Source 2856 K Short Term... ± 0.5% Long Term... ± 2% 100 hours/1 year Spectral Radiance 550 nm... ± 2% relative to NIST Sphere Coating (reflectance)...> 99% (350 to 1100 nm) Variable Aperture... Automated Micrometer(Motorized) Shutter... Automated (Open/Closed) OL 462-C CONTROLLER Luminance Display (5 digits)... fl or cd/m 2 * Luminance Display Range to 50,000 fl (Auto-ranging) Lamp Current Display... 4 digits Range... 0 to amperes DC Power Cycle second ramp function Accuracy... ± amperes Regulation... ± 0.01% for 10% line variation Temperature Regulation... ± 0.025%/10 C Lamp Timer... 0 to 1000 hours Operating Temperature Range to 35 C Operating Humidity Range... 10% to 85% (noncondensing) Power (user selectable) or 230 VAC ± 10%, 50/60 Hz Size x 18 x 5¼ Weight lbs. * Luminance can be displayed in other units. LUMINANCE LEVELS (nominal) Model Number Sphere Exit Port Uniformity Maximum K Display Resolution OL ±1.0% 22,000 fl fl fl OL ½ ±1.0% 12,000 fl 20,000 fl fl OL ±1.0% 9,000 fl 13,000 fl fl OL ±1.0% 4,000 fl 6,400 fl fl OL ±2.0% 700 fl 1,100 fl fl Other configurations available upon request. CALIBRATION OPTIONS OL 462-X... luminance, color temperature OL 462-X-1... luminance, color temperature, 1/ spectral radiance (350 to 1100 nm) OL 462-X-2... luminance, color temperature, 1/ spectral radiance (350 to 2500 nm) OL 462-X-U... uncalibrated Note: "X" designates the diameter of the integrating sphere. 1/ Spectral radiance measured at a color temperature of ~3000K unless otherwise specified. Bulletin 119 / Rev 7-11 Page 2 of 2

13 OL Series 466 Automated Low Light Level Integrating Sphere Calibration Standard GENERAL The OL Series 466 Automated Low-Light-Level Integrating Sphere Calibration Standard is designed for accurately calibrating very sensitive instruments such as microphotometers, telephotometers, image intensifiers, and imaging spectroradiometers for photometric, radiometric, or spectroradiometric response at moderate to extremely low light levels. It serves as a highly accurate, large area, uniform, diffusely radiating source with a near normal luminance that can be varied over decades with essentially constant color temperature. The OL Series 466 consists of an optics head and a separate microprocessor controlled luminance display/lamp power supply/motor controller console (OL 462-C Controller). This enables remote location of either unit, which facilitates alignment or positioning of the source with respect to the device to be calibrated. The source module/optics head is designed such that it can be configured with integrating spheres having diameters of 4, 6, 8, 12 and 18 inches with exit (radiating) ports of 1, 1½, 2, 3 and 6 inches, respectively. OPTICS HEAD The OL 466 is based on a dual integrating sphere design, with the arrangement of these spheres in series. The exit port of the first sphere, or primary sphere, produces a uniform beam into the entrance port of the secondary sphere. A baffle tube connects the exit port of the primary sphere to the entrance port of the secondary sphere, and an aperture in the baffle tube determines how much light is allowed into the secondary sphere, thus the maximum luminance at the radiating port can range over several decades depending on the size of the aperture installed. The aperture is not used to determine the true luminance at the exit port of the secondary sphere but merely scale it by the desired amount. A precision silicon detector-filter combination with an accurate photopic response mounted in the wall of the primary sphere tracks the luminance in the primary sphere at higher levels for accuracy purposes, and the luminance display is scaled to indicate the actual luminance at the exit port of the secondary sphere. The actual luminance of the exit port is calibrated via measurements, and then the monitor detector gain is scaled appropriately via a calibration factor programmed into memory. The optics head has a 150-W tungsten-halogen, reflectorized lamp with a motorized, computer controlled, variable aperture between the lamp and the entrance port of the primary sphere. This combination provides for continuous adjustment of the sphere luminance over a range of more than 10 6, which is tracked and displayed by the OL 462-C Controller. The in-line sphere port concept with an intermediate spider baffle provides for exceptional uniformity in the near normal luminance across the radiating port. A motorized, computer-controlled shutter is located between the lamp and the entrance port of the primary sphere. The luminance/ radiance output can be switched between zero and any desired level without adjustment or lamp changes. An optional filter holder mounted at the exit port accommodates alignment targets, filters, de-coupling diffusers, etc. for specific user requirements. Spectral shaping filters can be utilized to simulate various sources such as illuminates A, B, C, D65, etc. In addition to luminance and color temperature, the OL Series 466 can be obtained with calibration for spectral radiance over the 350 to 1100 nm wavelength range. CONTROLLER The microprocessor based OL 462 Controller performs all the system interface and monitoring functions. An automatic ramp up/ down function eliminates potentially dangerous current surges to the lamp. Luminance, color temperature, lamp current and operational prompts are displayed on a two line by 20 character alphanumeric vacuumfluorescent display. A 20-key keypad, rotary encoder knob, and main system power switch are also located on the front panel for easy access to all system functions. Luminance is displayed with 5 digit resolution in units specified by the user. As an option, the display can be factory programmed to read out in virtually any pertinent units the user desires. The Controller computes the color temperature of the source and displays lamp current or color temperature over the range of 2000 to 3000K. The luminance, color temperature, and lamp current can also be set by an external computer via the standard RS-232C interface. RS-422 and GPIB (IEEE-488) interfaces are also available. An internal microprocessor controlled lamp timer enables the user to track the number of hours the lamp has been in operation. Bulletin 118 / Rev 7-11 Page 1 of 2

14 OL Series 466 Automated Low Light Level Integrating Sphere Calibration Standard OL 466-OH OPTICS HEAD Luminance Uncertainty... ± 2 % relative to NIST Color Temperature Range to 3000 K Color Temperature Uncertainty... ± 25 K Source 2856 K Short Term... ± 0.5% Long Term... ± 2% 100 hours/1 year Spectral Radiance 550 nm... ± 2% relative to NIST Sphere Coating (reflectance)... > 99% (350 to 1100 nm) Variable Aperture... Automated Micrometer (Motorized) Shutter... Automated (Open/Closed) OL 462-C CONTROLLER Luminance Display (5 digits)... fl or cd/m 2 * Luminance Display Range... 1 E-8 to 50,0000 fl (Auto-ranging) Lamp Current Display... 4 digits Range... 0 to amperes DC Power Cycle second ramp function Accuracy... ± amperes Regulation... ± 0.01% for 10% line variation Temperature Regulation... ± 0.025%/10 C Lamp Timer... 0 to 1000 hours Operating Temperature Range to 35 C Operating Humidity Range... 10% to 85% (noncondensing) Power (user selectable) or 230 VAC ± 10%, 50/60 Hz Size x 18 x 5¼ Weight lbs. *Luminance can be displayed in other units. Model Number Sphere Exit Port LUMINANCE LEVELS (nominal) Uniformity Maximum K Display Resolution OL ±1.0% 80 fl 130 fl 0.5 E-7 fl OL ½ ±1.0% 40 fl 70 fl 0.4 E-7 fl OL ±1.0% 29 fl 40 fl 0.2 E-7 fl OL ±1.0% 14 fl 23 fl 1.0 E-7 fl OL ±2.0% 4 fl 7 fl 1.0 E-8 fl Other configurations available upon request. CALIBRATION OPTIONS OL 466-X... luminance, color temperature OL 466-X-1... luminance, color temperature, 1/ spectral radiance (350 to 1100 nm) OL 466-X-U... uncalibrated * Note: "X" designates the diameter of the integrating sphere. 1/ Spectral radiance measured at a color temperature of ~3000K unless otherwise specified. Bulletin 118 / Rev 7-11 Page 2 of 2

15 OL 480 Blackbody Calibration Standard The OL 480 Blackbody Calibration Standard provides an accurate, high temperature (100 to 1200 C) source of infrared radiation. It is specifically designed for calibrating infrared radiometric and spectroradiometric measurement systems. The blackbody features a unique, uniformly heated recessed cone cavity with an emissivity of 0.99 ± Accuracy of calibration is ensured by the use of a NISTtraceable platinum vs. platinum 10% rhodium thermocouple. An 8-position aperture wheel provides a convenient means of controlling the flux radiated by the blackbody (Table 1). The small aperture sizes enable the source to be used as a point source target at a finite working distance, while the larger apertures allow direct calibrations for radiance. A convenient microprocessor-based, self-tuning digital PID controller holds the selected temperature to within ± 0.05% of full scale. The controller has dual displays with the lower display indicating the desired set point and the upper display indicating the actual blackbody source temperature. The OL 480 features: Digital Controller Direct Mount Modulators Available 16 Interval Ramp and Hold from Front Panel Two (2) Customer Configured Alarm Relays One (1) Year Warranty RS-232C/422A/485 or IEEE-488 (optional) Temperature Range Accuracy Resolution Overall System Stability Cavity Opening Cavity Type SPECIFICATIONS SOURCE 50 to 1200 C 50 to 1050 C (optional) ± 0.2% ± 1 digit 0.1 C ± 0.02% of full scale per 24 hour period 1.0 (25mm) Recessed 20 cone Emissivity 0.99 ± 0.01 Sensing Element Max. Aperture Temp Rise Max. Housing Temp Rise Type S Thermocouple Platinum/Platinum-10% Rhodium special 0.01% tolerance, matched to sensing T/C 30 C 20 C Dimensions X 8 X 11.4 Net Weight CONTROL MODULE 17 lbs. Dimensions 5.1 X 12 X 13.4 Net Weight Warm-Up time (ambient to 1200 C) Operating temperature Controller Cooling Power req. 9 lbs. 50 minutes 0-50 C Digital Auto-Tune PID Fan cooled vac,50/60Hz,1 Phase 5.0 amp max 220 vac option available (installed internally) Bulletin 104 / Rev 9-12 Page 1 of 2

16 OL 480 Blackbody Calibration Standard Inches Table 1 Aperture Sizes Millimeters 1.000* 25.40* *Cavity Opening Blackbody Spectral Radiant Emittance At Various Temperatures Bulletin 104 / Rev 9-12 Page 2 of 2

OL 730CV Virtual Radiometer/Photometer PC-Controlled Virtual Instrument

OL 730CV Virtual Radiometer/Photometer PC-Controlled Virtual Instrument OL 730CV Virtual Radiometer/Photometer PC-Controlled Virtual Instrument The OL 730CV Virtual Radiometer/ Photometer sets a new standard in economically-priced, research-grade light measurement instrumentation

More information

SR-80 EXTENDED AREA BLACKBODY

SR-80 EXTENDED AREA BLACKBODY SR-80 EXTENDED AREA BLACKBODY PRODUCT TECHNICAL DESCRIPTION Rev. C Prepared by CI Systems, Inc. 30961 West Agoura Road, Suite 109 Westlake Village, CA 91361-4618 Tel: 818-865-0402 Fax: 818-865-0403 Email:

More information

Model S471-LED Optometer

Model S471-LED Optometer Model S471-LED Optometer For over 40 years UDT Instruments, a Gamma Scientific company, has been trusted by the world s leading organizations to provide accurate light measurement systems. UDT Instruments

More information

Application Note (A16)

Application Note (A16) Application Note (A16) Eliminating LED Measurement Errors Revision: A December 2001 Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1 407 422 3171 Fax: 1 407 648 5412 Email: sales@goochandhousego.com

More information

Blackbody Radiation Calibration Sources From -20 C to 3000 C traceable to NIST

Blackbody Radiation Calibration Sources From -20 C to 3000 C traceable to NIST Blackbody Radiation Calibration Sources From -20 C to 3000 C traceable to NIST Mikron Blackbody Radiation Calibration Sources Mikron has been designing and building blackbody calibration sources since

More information

Pulsed Laser Power Measurement Systems

Pulsed Laser Power Measurement Systems Pulsed Laser Power Measurement Systems Accurate, reproducible method of determining total laser and laser diode power Ideal for Beam Power Measurement Labsphere s Pulsed Laser Power Measurement Systems

More information

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan 0.000005 fl 0.0001 fl Polarization Error - Under 0.20% Introduction We have taken our decades of experience and built it into the ultimate

More information

ISS-30-VA. Product tags: Integrating Sphere Source. https://www.gigahertz-optik.de/en-us/product/iss-30-va. Gigahertz-Optik GmbH 1/5

ISS-30-VA. Product tags: Integrating Sphere Source. https://www.gigahertz-optik.de/en-us/product/iss-30-va. Gigahertz-Optik GmbH 1/5 ISS-30-VA https://www.gigahertz-optik.de/en-us/product/iss-30-va Product tags: Integrating Sphere Source Gigahertz-Optik GmbH 1/5 Description standards for spectral radiance Spectroradiometers and other

More information

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790 Calibration Standard for Sighting & Imaging Devices 2223 West San Bernardino Road West Covina, California 91790 Phone: (626) 962-5181 Fax: (626) 962-5188 www.davidsonoptronics.com sales@davidsonoptronics.com

More information

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration SpectralLED RS-7-1-VIS Benchtop Uniform Light Source For the ultimate in resolution and accuracy, the SpectralLED Tunable VIS source incorporates 35 discrete wavelengths for synthesis of commercially available

More information

LED Lighting Flux and Color Measurement System (LFC)

LED Lighting Flux and Color Measurement System (LFC) LED Lighting Flux and Color Measurement System (LFC) Fast, accurate and complete System for research and production LFC System is a high cost efficiency light measurement system. The system is designed

More information

illumia Plus Temperature Controlled Light Measurement Systems

illumia Plus Temperature Controlled Light Measurement Systems illumia Plus Temperature Controlled Light Measurement Systems Allows testing over a broad range of temperatures Measure with Confidence When a solid-state light engine is used in a luminaire or fixture,

More information

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold 1354 MINIS Oriel Integrating Spheres Integrating spheres are ideal optical diffusers; they are used for radiometric measurements where uniform illumination or angular collection is essential, for reflectance

More information

JETI Specbos Instruments

JETI Specbos Instruments Spectral measuring instruments for various applications JETI Specbos Instruments The new Specbos family offers compact, spectrometric instruments, designed to measure the color coordinates, spectral characteristics

More information

LI-1500 Light Sensor Logger

LI-1500 Light Sensor Logger LI-1500 Light Sensor Logger The LI-1500 Light Sensor Logger provides a direct digital readout and data logging from up to three LI-COR sensors at the same time. Log manually or set up one-time, daily,

More information

Tunable KiloArc. Tunable Broadband Light Source.

Tunable KiloArc. Tunable Broadband Light Source. Optical Building Blocks Corporation Tunable KiloArc Tunable Broadband Light Source www.obb1.com Tunable KiloArc Need a CW laser that is tunable from 250 to 1,100 nm? yes Need it to deliver Hundreds of

More information

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration Technical Notes Integrating Sphere Measurement Part II: Calibration This Technical Note is Part II in a three part series examining the proper maintenance and use of integrating sphere light measurement

More information

AvaLight-DHc Full-range Compact Light Source

AvaLight-DHc Full-range Compact Light Source AvaLight-DHc Full-range Compact Light Source AvaLight-DHc Get the best out of two worlds with the AvaLight-DHc. It has both a deuterium light source and a halogen light source, providing you with adequate

More information

We bring quality to light. MAS 40 Mini-Array Spectrometer

We bring quality to light. MAS 40 Mini-Array Spectrometer MAS 40 Mini-Array Spectrometer Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters Different models

More information

Compact High Intensity Light Source

Compact High Intensity Light Source Compact High Intensity Light Source General When a broadband light source in the ultraviolet-visible-near infrared portion of the spectrum is required, an arc lamp has no peer. The intensity of an arc

More information

Microscope-Spectrometer

Microscope-Spectrometer 20 Micro-spectrometer ToupTek s spectrometer is applicable for spectral detection within the wavelength range between 200nm and 1100nm. Due to their high stability and performance, these portable instruments

More information

New automated laser facility for detector calibrations

New automated laser facility for detector calibrations CORM annual conference, NRC, Ottawa, CANADA June 1, 2012 New automated laser facility for detector calibrations Yuqin Zong National Institute of Standards and Technology Gaithersburg, Maryland USA Overview

More information

BTS2048-VL-CP-ILED-B-IS-1.0-HL

BTS2048-VL-CP-ILED-B-IS-1.0-HL BTS2048-VL-CP-ILED-B-IS-1.0-HL https://www.gigahertz-optik.de/en-us/product/bts2048-vl-cp-iled-b-is-1.0-hl Product tags: VIS, NIR, Spectral Data, LED Binning, CIE 127, ILED-B, LED Gigahertz-Optik GmbH

More information

Influence of the light spectral distribution used in the radiometers calibration

Influence of the light spectral distribution used in the radiometers calibration Influence of the light spectral distribution used in the radiometers calibration J C Moraes and L O Guerra Allergisa Pesquisa Dermato-Cosmética Ltda GRUPO INVESTIGA, 452. Dr. Romeu Tórtima Avenue, Postcode:

More information

Spectroradiometer specbos 1201

Spectroradiometer specbos 1201 Spectroradiometer specbos 1201 specbos 1201 is a precise and compact VIS spectroradiometer. It can be used in laboratory as well as production environment to measure the following quantities: Luminance,

More information

LBIR Fluid Bath Blackbody for Cryogenic Vacuum Calibrations

LBIR Fluid Bath Blackbody for Cryogenic Vacuum Calibrations LBIR Fluid Bath Blackbody for Cryogenic Vacuum Calibrations Timothy M. Jung*, Adriaan C. Carter*, Dale R. Sears*, Solomon I. Woods #, Dana R. Defibaugh #, Simon G. Kaplan #, Jinan Zeng * Jung Research

More information

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET

NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET REPLACE NEAR EYE DISPLAY (NED) SPECTRORADIOMETER SYSTEMS DATASHEET 9925 Carroll Canyon Road San Diego, CA 92131 (800) 637-2758 (858) 279-8034 Fax (858) 576-9286 www.gamma-sci.com About Gamma Scientific:

More information

NIRCam optical calibration sources

NIRCam optical calibration sources NIRCam optical calibration sources Stephen F. Somerstein, Glen D. Truong Lockheed Martin Advanced Technology Center, D/ABDS, B/201 3251 Hanover St., Palo Alto, CA 94304-1187 ABSTRACT The Near Infrared

More information

Oriel Flood Exposure Sources

Oriel Flood Exposure Sources 218 Oriel Flood Exposure Sources High intensity outputs CALIBRATION SOURCES Highly uniform, large collimated beams Efficient out of band rejection Timed exposures DEUTERIUM SOURCES ARC SOURCES INCANDESCENT

More information

SPECTRORADIOMETRY METHODS: A GUIDE TO PHOTOMETRY AND VISIBLE SPECTRORADIOMETRY

SPECTRORADIOMETRY METHODS: A GUIDE TO PHOTOMETRY AND VISIBLE SPECTRORADIOMETRY SPECTRORADIOMETRY METHODS: A GUIDE TO PHOTOMETRY AND VISIBLE SPECTRORADIOMETRY Written By William E. Schneider, Richard Young, Ph.D 1. SPECTRORADIOMETRY METHODS 1.1. Spectroradiometrics vs Photometric

More information

Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains

Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains Measurement Science and Standards (MSS) Current and Future Realizations NRC Photometric and Spectroradiometric Calibration Chains Arnold A. Gaertner Photometry, Radiometry and Thermometry (PRT) CORM 30

More information

The Standard for over 40 Years

The Standard for over 40 Years Light Measurement The Standard for over 40 Years Introduction LI-COR radiation sensors measure the flux of radiant energy the energy that drives plant growth, warms the earth, and lights our world. The

More information

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED. https://www.gigahertz-optik.de/en-us/product/bts2048-uv

BTS2048-UV. Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED. https://www.gigahertz-optik.de/en-us/product/bts2048-uv BTS2048-UV https://www.gigahertz-optik.de/en-us/product/bts2048-uv Product tags: UV, Spectral Data, LED Binning, Industrial Applications, LED Gigahertz-Optik GmbH 1/8 Description UV CCD spectroradiometer

More information

LED Tester BTS256-LED

LED Tester BTS256-LED 1 LED Tester BTS256-LED The BTS256-LED tester is one of the most compact light measurement devices with integrated integrating sphere for high accuracy measurement of luminous flux, spectral and color

More information

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features

OTFI 0285 XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features DATASHEET Lighting Solutions XLM Plus High CRI LED Fiber Optic Light Module with Electronics Key Features Color Rendering Index (CRI) over 90 with R9 values typically over 80 Bright Light intensity is

More information

Calibration of a High Dynamic Range, Low Light Level Visible Source

Calibration of a High Dynamic Range, Low Light Level Visible Source Calibration of a High Dynamic Range, Low Light Level Visible Source Joe LaVeigne a, Todd Szarlan a, Nate Radtke a a Santa Barbara Infrared, Inc., 30 S. Calle Cesar Chavez, #D, Santa Barbara, CA 93103 ABSTRACT

More information

Broadbandradiometer specbos 1211

Broadbandradiometer specbos 1211 Broadbandradiometer specbos 1211 specbos 1211 is a broadband and fast spectroradiometer which can be used in laboratory as well as production environment to measure the following quantities: Luminance,

More information

Photometry and Light Measurement

Photometry and Light Measurement Photometry and Light Measurement Adrian Waltho, Analytik Ltd adrian.waltho@analytik.co.uk What is Light? What is Light? What is Light? Ultraviolet Light UV-C 180-280 nm UV-B 280-315 nm UV-A 315-400 nm

More information

Cornerstone 260 1/4 m Monochromators

Cornerstone 260 1/4 m Monochromators Cornerstone /4 m Monochromators The Oriel Cornerstone is a high performance, economical and user-friendly monochromator an ideal instrument for research and OEM applications. Oriel has made it easy to

More information

MAKING LIGHT WORK OF LIGHT MEASUREMENT. Guide to Photometer & Radiometer. System Configuration

MAKING LIGHT WORK OF LIGHT MEASUREMENT. Guide to Photometer & Radiometer. System Configuration MAKING LIGHT WORK OF LIGHT MEASUREMENT Guide to Photometer & Radiometer System Configuration System Configuration Guide for PHOTOMETRY & RADIOMETRY TABLE OF CONTENTS System Configuration Guide Optometers

More information

Development of 2 Total Spectral Radiant Flux Standards at NIST

Development of 2 Total Spectral Radiant Flux Standards at NIST CIE/USA Annual Conference, October 7, 2014, Seattle, WA Development of 2 Total Spectral Radiant Flux Standards at NIST Yuqin Zong National Institute of Standards and Technology Gaithersburg, Maryland Outline

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03145 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03414 PAGE: 1 OF 9 LUMINAIRE: EXTRUDED METAL HOUSING WITH HEAT SINK FINS, TWO WHITE CIRCUIT BOARD WITH THREE HUNDRED LEDS ON EACH BOARD, METAL REFLECTOR WITH SPECULAR FINISH, FLAT TRANSLUCENT

More information

Table 8 Overview light sources

Table 8 Overview light sources Avantes Deuterium light sources are known for their stable output and are used for UV absorption or reflection measurements. These can also be used as irradiance calibration sources due to their high-stability.

More information

Model 332 Temperature Controller

Model 332 Temperature Controller 94 Instruments Model 332 Temperature Controller Features Operates down to 500 mk with appropriate NTC RTD sensors Model 332 Temperature Controller Two sensor inputs Supports diode, RTD, and thermocouple

More information

LI-193 Spherical Quantum Sensor

LI-193 Spherical Quantum Sensor LI-193 Spherical Quantum Sensor The LI-193 Spherical Quantum Sensor measures PAR in air or underwater from all directions at depths up to 350 meters. This sensor is useful for studies of phytoplankton,

More information

MS260i 1/4 M IMAGING SPECTROGRAPHS

MS260i 1/4 M IMAGING SPECTROGRAPHS MS260i 1/4 M IMAGING SPECTROGRAPHS ENTRANCE EXIT MS260i Spectrograph with 3 Track Fiber on input and InstaSpec IV CCD on output. Fig. 1 OPTICAL CONFIGURATION High resolution Up to three gratings, with

More information

Fully Portable Spectrophotometer for Transmission Measurement

Fully Portable Spectrophotometer for Transmission Measurement November 2008 LCRT-2005-S Portable Spectrophotometer for Transmission Measurement Spectral Transmission in d/0 and 0/0 Measurement Geometries Transparency Measurement in real in-line Set-up Photometric

More information

Lambda 1050 / 950 UV/Vis/NIR

Lambda 1050 / 950 UV/Vis/NIR www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Lambda 1050 / 950 UV/Vis/NIR LAMBDA 1050 Choose the LAMBDA 1050 with its triple

More information

Instruction Manual of Luminance and Spectral Radiance Calibrations

Instruction Manual of Luminance and Spectral Radiance Calibrations Aalto University School of Electrical Engineering Metrology Research Institute Jari Hovila Pasi Manninen Tuomas Poikonen Petri Kärhä Instruction Manual of Luminance and Version 2.6 07/12/2015 Page 2 (19)

More information

1/8 m GRATING MONOCHROMATOR

1/8 m GRATING MONOCHROMATOR 1/8 m GRATING GRATING OUTPUT PORT INPUT PORT 77250 1/8 m Monochromator with 6025 Hg(Ar) Spectral Calibration Lamp. Low cost, compact size and high performance, ideal for OEM applications Very efficient

More information

Measuring Spectral Performance of Night Vision Devices

Measuring Spectral Performance of Night Vision Devices Specialized Spectral Measurement Equipment And Techniques Dominate Night Vision Applications Since the inception of night vision equipment in the early 1950s the development of night vision goggles has

More information

Gamma Scientific Display Measurement Systems

Gamma Scientific Display Measurement Systems Gamma Scientific Display Measurement Systems 9925 Carroll Canyon Road San Diego, CA 92131 858-279-8034 contact@gamma-sci.com www.gamma-sci.com Since 1961 Gamma Scientific has produced LED, display and

More information

Solid State Luminance Standards

Solid State Luminance Standards Solid State Luminance Standards Color and luminance correction of: - Imaging colorimeters - Luminance meters - Imaging spectrometers Compact and Robust for Production Environments Correct for instrument

More information

LINEARPYROMETER LP4. Technical Documentation KE November TN

LINEARPYROMETER LP4. Technical Documentation KE November TN 1 LINEARPYROMETER LP4 Technical Documentation KE 256-6.2007 November 2010 5-TN-1622-100 2 1. General Description With the Linearpyrometer Type LP4 a measuring instrument has been made available for pyrometric

More information

LI-192 Underwater Quantum Sensor

LI-192 Underwater Quantum Sensor LI-192 Underwater Quantum Sensor The LI-192 Underwater Quantum Sensor measures PAR from all angles in one hemisphere. The LI-192 works in air or underwater at depths up to 560 meters. The measurements

More information

Oriel Cornerstone 130 1/8 m Monochromator

Oriel Cornerstone 130 1/8 m Monochromator 1 Oriel Cornerstone 130 1/8 m Monochromator Cornerstone 130 1/8 m Monochromator The Cornerstone 130 family of Oriel Monochromators supports two gratings simultaneously, which can be easily interchanged,

More information

CS-2000/2000A. Spectroradiometer NEW

CS-2000/2000A. Spectroradiometer NEW Spectroradiometer NEW CS-000/000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. World's top level capability to detect extremely low

More information

CBT-90-UV-405 LEDs. CBT-90-UV-405 CBT-120 Product Datasheet. Features: Table of Contents. Applications

CBT-90-UV-405 LEDs. CBT-90-UV-405 CBT-120 Product Datasheet. Features: Table of Contents. Applications CBT-9-UV-45 CBT-2 Product Datasheet Datasheet CBT-9-UV-45 LEDs Table of Contents Technology Overview...2 Optical & Electrical Characteristics...3 Features: >6.5 W of optical power from 4 nm to 4 nm. High

More information

CBT-120. Monolithic Die Series Ultraviolet Chip On Board LEDs. CBT-120-UV Product Datasheet. Features: Table of Contents.

CBT-120. Monolithic Die Series Ultraviolet Chip On Board LEDs. CBT-120-UV Product Datasheet. Features: Table of Contents. CBT-2 Monolithic Die Series Ultraviolet Chip On Board LEDs Table of Contents Technology Overview.... 2 Ordering Information... 3 Binning Structure.... 4 Optical & Electrical Characteristics.... 5 Optical

More information

High Illuminance Calibration Facility and Procedures

High Illuminance Calibration Facility and Procedures Final manuscript for J. IES, 27-2, 132-140 (1998) High Illuminance Calibration Facility and Procedures Yoshi Ohno Optical Technology Division National Institute of Standards and Technology Metrology A320,

More information

Source Four 19. Ellipsoidal Series. Source Four. Connector Designation

Source Four 19. Ellipsoidal Series. Source Four. Connector Designation Source Four 19 S p E C I F I C A T I O N S physical Rugged, die cast aluminum construction Rotating shutter assembly ±25 20 gauge stainless steel shutters in a tri-plane assembly Interchangeable lens tubes

More information

Systems & Accessories

Systems & Accessories Light Source Sample Chambers Stepping Motor Controller Detector Variable Wavelength Fiber Optics Modules Tunable Light Sources For Applications In: Analytical Chemistry Physics Life Sciences Engineering

More information

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS) Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS) Specifications Introduction The Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS) is designed for superior performance, flexibility

More information

Photometry for Traffic Engineers...

Photometry for Traffic Engineers... Photometry for Traffic Engineers... Workshop presented at the annual meeting of the Transportation Research Board in January 2000 by Frank Schieber Heimstra Human Factors Laboratories University of South

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB03176 PAGE: 1 OF 9 LUMINAIRE: CAST WHITE PAINTED FINNED METAL HEAT SINK,SHEETMETAL JUNCTION BOX AFFIXED TO TOP OF HEATSINK, 1 CIRCUIT BOARD WITH 10 LEDS. LAMPS: TEN WHITE MULTI-CHIP LIGHT

More information

Croma Enterprise Cromtech India

Croma Enterprise Cromtech India UV 1601 - Split Beam & Dual (equivalent to Double beam Spectro Photometer ) Wide wavelength range, satisfying requirements of various fields. The split-beam ratio monitoring system provides accurate measurements

More information

OP735. Benchtop Optical Power Meter Instruction Manual

OP735. Benchtop Optical Power Meter Instruction Manual Benchtop Optical Power Meter Instruction Manual www.optotest.com 1.805.987.1700 Contacting OptoTest Corporation 1.805.987.1700 (7:30 a.m. to 5 p.m. PST) www.optotest.com engineering@optotest.com OptoTest

More information

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights... LIGHT SOURCES Table of Content Fiber-Coupled s... 40 -Guide-Coupled s... 41 Collimator... 42 Low-cost Spot s... 43 Precision Spot s... 45 Spectrum Synthesizing ( Cubic S )... 46 Spectrometers 39 sources

More information

Oriel Sol3A Class AAA Solar Simulators

Oriel Sol3A Class AAA Solar Simulators Leveraging over 40 years of experience in light source and supply design, Newport s Output beam sizes 2x2", 4x4, 6x6, 8x8", and x " Factory certified Class AAA CW systems Calibration certificate validating

More information

Cornerstone 130 1/8 m Monochromators

Cornerstone 130 1/8 m Monochromators Cornerstone 130 1/8 m Monochromators The Oriel Cornerstone 130 is a high performance, economical and user-friendly monochromator an ideal instrument for research and OEM applications. Oriel has made it

More information

Application Note (A11)

Application Note (A11) Application Note (A11) Slit and Aperture Selection in Spectroradiometry REVISION: C August 2013 Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1 407 422 3171 Fax: 1 407 648 5412 Email: sales@goochandhousego.com

More information

The Standard for over 40 Years

The Standard for over 40 Years Light Measurement The Standard for over 40 Years Introduction LI-COR radiation sensors measure the flux of radiant energy the energy that drives plant growth, warms the earth, and lights our world. The

More information

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser. BTS2048-BS http://www.gigahertz-optik.de/en-us/product/bts2048-bs Product tags: VIS, Spectral Data, Industrial Applications, Laser Gigahertz-Optik GmbH 1/6 Description BTS2048-BS CCD spectroradiometer

More information

BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane)

BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane) BGS400 Lamp & Luminaire Goniophotometer (C-γ, B-ß Plane) BGS400 Luminaire Goniophotometer (C-γ, B-ß Plane ) The BGS400 moving lamp and luminaire gonio-photometer is an economical, turnkey solution for

More information

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum. Page 1 BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum. The BTS256-E WiFi is a high-quality light meter

More information

Application Note (A19)

Application Note (A19) Application Note (A19) Reducing Uncertainty in Precision High-Brightness LED Measurements Revision: A December 2005 Gooch & Housego 4632 36 th Street, Orlando, FL 32811 Tel: 1 407 422 3171 Fax: 1 407 648

More information

GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM

GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM GHOLOGRAPHIC COMPANY LIGHT MEASUREMENT SYSTEM Goniophotometer / Integrating Sphere/ Spectroradiometer/ Illuminance Meter Luminance Meter / UV Radiometer Benefits Easy to Use High End Product Precise Measurement

More information

CBT-90-UV LEDs. CBT-90-UV CBT-120 Product Datasheet Preliminary. Features: Table of Contents. Applications

CBT-90-UV LEDs. CBT-90-UV CBT-120 Product Datasheet Preliminary. Features: Table of Contents. Applications CBT-9-UV CBT-2 Product Datasheet Preliminary CBT-9-UV LEDs Features: Table of Contents Technology Overview.... 2 CBT-9 Bin Structure... 3 Greater than 2 W of optical power from 4 nm to 4 nm. High thermal

More information

FiberLight Miniature UV-Vis Light Source for Mobile Spectroscopy and Online Process Control

FiberLight Miniature UV-Vis Light Source for Mobile Spectroscopy and Online Process Control FiberLight Miniature UV-Vis Light Source for Mobile Spectroscopy and Online Process Control FiberLight Miniature UV-Vis Light Source FiberLight DTM 6/10 FiberLight is a compact UV-Vis light source designed

More information

Ultraviolet Visible Infrared Instrumentation

Ultraviolet Visible Infrared Instrumentation Ultraviolet Visible Infrared Instrumentation Focus our attention on measurements in the UV-vis region of the EM spectrum Good instrumentation available Very widely used techniques Longstanding and proven

More information

NVLAP LAB CODE:

NVLAP LAB CODE: REPORT NUMBER: RAB01271 PAGE: 1 OF 5 LUMINAIRE: LUMINAIRE: FABRICATED WHITE PAINTED METAL HOUSING, 4 WHITE CIRCUIT BOARDS EACH WITH 120 LEDS, FROSTED HOLOGRAPHIC PLASTIC LENS. LENS FROSTED SIDE UP. LAMPS:

More information

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. Spectroradiometer CS-000/000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. 15 World's top level capability to detect extremely low

More information

TracQ. Basic Data Acquisition and Spectroscopy Software

TracQ. Basic Data Acquisition and Spectroscopy Software Basic Data Acquisition and Spectroscopy Software TracQ Basic main application window. Many common spectroscopic measurements require coordinated operation of a detection instrument and light source, as

More information

CBT-120-UV LEDs. CBT-120-UV Product Datasheet. Features: Table of Contents. Applications

CBT-120-UV LEDs. CBT-120-UV Product Datasheet. Features: Table of Contents. Applications CBT-2-UV LEDs Features: Table of Contents Technology Overview.... 2 Binning Structure.... 3 Optical & Electrical Characteristics.... 4 Optical Electrical Characteristics Graphs... 5 Over 6. W of optical

More information

We bring quality to light. Spectro 320 Scanning Spectrometer

We bring quality to light. Spectro 320 Scanning Spectrometer We bring quality to light. Spectro 320 Scanning Spectrometer light measurement Instrument description Applications Spectroradiometry NVIS Display measurements Specifications Key features at a glance Fast-Scan

More information

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup.

Spectroradiometer CS-2000/2000A. The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. Spectroradiometer /000A The world's top-level capability spectroradiometers make further advances with addition of second model to lineup. World's top level capability to detect extremely low luminance

More information

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone: 2 3 IMPORTANT SAFETY NOTE: Before operating this device, please read carefully this User Manual and be familiar with its contents prior to using this equipment. To help avoid potential serious injury to

More information

Additel 875 Series Dry Well Calibrators

Additel 875 Series Dry Well Calibrators Additel 875 Series Dry Well Calibrators Three models ranging from -40 to 660 Portable, rugged, and quick to temperature Metrology-level performance in stability, uniformity, accuracy and loading effect

More information

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date: IES LM 79 08 Test Report Test results reported for: report: Original issue date: LED Lamp 001 LEDC001 010 WG 1 January 2012 Prepared for: Testing performed by: LED ABC, Inc. Memorial Highway 1003 7th Ave.

More information

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system Visible range spectrophotometers V-1100 and VR-2000 V-1100 MODEL WITH MANUAL WAVELENGTH SETTINGS AND AUTOMATIC BLANK. VR-2000 MODEL WITH AUTOMATIC WAVELENGTH SETTINGS AND BLANK. V-1100 Part no. 4120025

More information

Photometry for Traffic Engineers...

Photometry for Traffic Engineers... Photometry for Traffic Engineers... Workshop presented at the annual meeting of the Transportation Research Board in January 2000 by Frank Schieber Heimstra Human Factors Laboratories University of South

More information

Oriel MS260i TM 1/4 m Imaging Spectrograph

Oriel MS260i TM 1/4 m Imaging Spectrograph Oriel MS260i TM 1/4 m Imaging Spectrograph MS260i Spectrograph with 3 Track Fiber on input and InstaSpec CCD on output. The MS260i 1 4 m Imaging Spectrographs are economical, fully automated, multi-grating

More information

The Right Tool for a Spectrum of Applications

The Right Tool for a Spectrum of Applications Pho Research, Inc. PR-655. PR-670. PR-680. PR-680L SpectraScan Spectroradiometer Contrast Ratio 1.1 Billion : 1 Measure 0.00007 fl The Right Tool for a Spectrum of Applications Aumotive Digital Cinema

More information

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2 Multispectral imaging device Most accurate homogeneity MeasureMent of spectral radiance UMasterMS1 & UMasterMS2 ADVANCED LIGHT ANALYSIS by UMaster Ms Multispectral Imaging Device UMaster MS Description

More information

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc. High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure Global Office of Lisun Electronics Inc. http://www.lisungroup.com Lisun Group (Hong Kong) Limited Add: Room

More information

Model 1140A Thermocouple Simulator-Calibrator

Model 1140A Thermocouple Simulator-Calibrator BULLETIN 2031 Model 1140A Thermocouple Simulator-Calibrator The Model 1140A represents the latest innovation in thermocouple simulator-calibrators from Ectron, the originator of the Thermocouple Simulator

More information

Chameleon Spectroradiometer

Chameleon Spectroradiometer Chameleon Spectroradiometer SPEED / STABILITY / ACCURACY The Chameleon Series is designed to measure the absolute spectral of power, of the light under test. Adding optical probes and absolute calibration

More information

PR-655 PR-670 PR-680 and PR-680L SpectraScan

PR-655 PR-670 PR-680 and PR-680L SpectraScan PR-655 PR-670 PR-680 and PR-680L SpectraScan Spectroradiometers INC. The Reference in Color and Light Measurement THE NEW ERA OF LIGHT AND COLOR MEASUREMENT Gone are the days when the calibration of displays

More information

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä

\Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä \Ç à{x ÇtÅx Éy ALLAH à{x `xüv yâä Ultraviolet Radiation from Some Types of Outdoor Lighting Lamps Dr.Essam El-Moghazy Photometry and Radiometry division, National Institute for Standards (NIS), Egypt.

More information