Nature Methods: doi: /nmeth Supplementary Figure 1

Size: px
Start display at page:

Download "Nature Methods: doi: /nmeth Supplementary Figure 1"

Transcription

1 . Supplementary Figure 1 Schematics and characterization of our AO two-photon fluorescence microscope. (a) Essential components of our AO two-photon fluorescence microscope: Ti:Sapphire laser; optional dispersion compensation unit (DCU); micromirror device (DMD) or segmented deformable mirror (SDM); field stop (FS) at an intermediate image plane between SDM/DMD and liquid crystal spatial light modulator (SLM); X galvanometer (X galvo); Y galvanometer (Y galvo); a photomultiplier tube (PMT). (b) The DCU unit is used with DMD, and consists of an anamorphic prism pair (APP) and an equilateral dispersive prism (EDP). (c) Images and the signal profiles of a 2 µm diameter fluorescent bead in the XY focal plane without and with DCU; Scale bar: 2 µm. (d) Two pupil-segmentation patterns used in this paper, where the active area of the SLM (colored squares) is inscribed to the back pupil of the objective (dashed circles).

2 Supplementary Figure 2 Schematics describing the multiplexed aberration-measurement method. See Details on the multiplexed aberration measurement method section of Online Methods.

3 Supplementary Figure 3 AO correction of GFP-labeled C. elegans neurons in vivo. (a) Imaging through the cylindrical body of a C. elegans. (b) Lateral and axial images of neurons before and after two iterations of AO, with a display gain of 1.8 for the images without AO. (c) Corrective wavefront in units of waves for (b). (d) Orthogonal views of neurons in another C. elegans. (e) Enlarged view of the area inside the dashed box in (d). (f) Axial images along the orange line in (e) before and after one iteration of AO. (g) Signal profiles along the pink line in (f). The improvement here is largely confined to the neuron on which AO correction was done because the large surface curvature of the worm led to a highly localized aberration. (h) Corrective wavefront in units of waves in (f). Crosses mark the neurons on which AO correction was carried out using intensity modulation with a DMD. Scale bar: 8 µm.

4 Supplementary Figure 4 AO correction of EGFP-labeled zebrafish larva in vivo. (a) Imaging through the zebrafish larva. (b) Aberration leads to signal degradation at depth after the excitation light passes through myotomes (MT) and notochord (NC). (c) Lateral and axial images of myotomes 170 µm inside a zebrafish larva before and after three iterations of AO correction at the red cross shown. Images without AO have display gains of 2.3, 2.3, and 1.6, respectively, for better visibility. (d) Corrective wavefront in units of waves. (e) Signal profiles along the cyan, pink, and blue lines in (e). Crosses mark the position where AO correction was carried out using intensity modulation with a DMD. Scale bar: 40 µm in (b), 10 µm in (c).

5 Supplementary Figure 5 The single-segment illumination AO method fails in densely labeled mouse brain, whereas the multiplexed method succeeds. (a) Images of neurons taken before and after AO correction using the single-segment illumination method. Orange square encircles the area used for correction. The improvement in imaging quality is minimal. (b) Images obtained by illuminating different pupil segments, arranged according to their respective pupil segments. The fluorescent background caused by the neighboring densely labeled structures obscure the image shift. As a result, the corrective wavefront (c) is very flat and does not reflect the aberrations in the sample. (d) Images taken before and after AO correction using multiplexed intensity modulation with a DMD. Note that the improvements in signal and resolution allow many more fine structures to be observed. (e) Signal vs. displacement map from the multiplexed measurement on the neuron marked with an orange cross in (d). The final corrective wavefront (f) now accurately shows the aberrations caused by the cranial window and the brain tissue. Scale bar: 10 µm.

6 Supplementary Figure 6 AO correction using signal from a fluorescent sea. (a) Using signal from a fluorescent sea, multiplexed intensity modulation with a DMD is used to correct for an artificial aberration introduced to the microscope. (b) Signal from the fluorescent sea increases over successive iterations of correction. (c) Axial images of a 2-µm-diameter bead measured without AO, without AO with 7.5 display gain, after five-iteration AO correction in fluorescent sea, and under ideal aberration-free condition, respectively. (d) Corrective wavefront in units of waves after five iterations of AO correction in (b). (e) Axial signal profile along the white line in (c). Scale bar: 2 µm.

7 Supplementary Table 1 Experimental parameters used for aberration measurement. Data AO method (modulation device) Modulation type Sample (labeling) Excitation power (mw) a Signal integration time (sec) Figure 1a DC Beads Figure 1a PM (DMD) Intensity Beads Figs. 2a,d PM (DMD) Intensity Mouse (GCaMP6s) Figs. 3a,c PM (SDM) Phase Mouse (YFP) Figs. 3f,g PM (SDM) Intensity Mouse (GCaMP6s) Supp. Fig. PM (DMD) Intensity C. elegans (GFP) b Supp. Fig. PM (DMD) Intensity C. elegans (GFP) f Supp. Fig. 4 PM (DMD) Intensity Zebrafish (GFP) Supp. Figs. PM (DMD) Intensity Mouse (GCaMP6s) a Excitation power was measured post microscope objective.

8 Supplementary Note: Multiplexed aberration measurement in C. elegans and zebrafish in vivo. The ultimate test of any AO method is in live biological samples, in which microscopic and sometimes macroscopic motions abound and photodamage as well as photobleaching limit the amount of light exposure. In addition to the mouse brain, we also tested our method in C. elegans and zebrafish, two of the most popular model organisms for bioimaging. Two examples of AO correction on GFP-labeled neurons in live C. elegans are shown (Supplementary Fig. 3). In both cases, we imaged neurons through the aberrating cylindrical bodies of the worms. In one example (Supplementary Fig. 3b,c), AO correction after two iterations improved both the signal (1.8 ) and resolution of two neurons in the deeper body wall. In the other (Supplementary Fig. 3d h), we corrected the aberration through the more densely labeled worm head by parking the focus at a bottom neuron. After one iteration of AO correction, the improvement in signal (2 ) and resolution was most prominent for the neuron on which the AO correction is done because the large surface curvature of the worm leads to a highly localized aberration (Supplementary Fig. 3f h). As an example of a very densely labeled sample, we applied the multiplexed aberration measurement method to in vivo imaging of 4-d-old zebrafish larvae, in which all cell membranes were labeled with EGFP. The axial views through the body of one larva showed notable signal and resolution deterioration for myotomes below the notochord (Supplementary Fig. 4a,b). After three rounds of AO correction at a myotome 170 µm inside the larva, the signal increased up to 2.3 in both lateral and axial imaging planes. More importantly than mere signal increase, the resolution improvement left various structural features much better resolved (Supplementary Fig. 4c,e). For example, the membrane folds could be easily observed after AO correction, the aberration-induced ghosts were eradicated, the individual membranes were much better separated, and the periodic structures of the myotome were much better visualized. Comparison with the single-segment illumination method. The signal-versus-displacement maps presented in Figure 1 reflect only the focal intensity variation relative to the ray displacement in focal plane and do not reflect or rely on specific fluorescent structures of the sample. Therefore, we can achieve AO correction from fluorescent samples of arbitrary structural complexity, including densely labeled fluorescent samples, for which the singlesegment illumination method 3 fails, because the reduction of excitation NA during single-

9 segment illumination allows the originally out-of-focus fluorescent structures to appear in the image and makes it difficult to determine wavefront gradients 2. For the same densely labeled mouse brain in vivo, the single-segment illumination method failed to improve signal quality, whereas the multiplexed method, which operates at the full NA of the objective, was able to improve image quality notably (Supplementary Fig. 5). An extreme example of a densely labeled fluorescent sample is a fluorescent solution ( fluorescent sea ). Without any structural feature, a fluorescent-sea sample cannot provide the image shift information that the single-segment illumination method needs to work. In contrast, the multiplexed aberration measurement method can be used to recover diffraction-limited resolution using signal in a fluorescein solution (Supplementary Fig. 6). Here an aberration was introduced to the system by overlaying a phase pattern on the SLM, which reduced the signal from a fluorescent sea by 1.7. Parking the laser at a fixed spot inside the fluorescent sea, and after five iterations with parallel intensity modulation, we fully recovered the signal from the fluorescent sea (Supplementary Fig. 6b). Because signal from a smaller object is much more sensitive to aberration than is a fluorescent sea 7, we tested how well this AO correction works by imaging a 2-µm-diameter fluorescent bead without and with AO correction obtained from the fluorescent sea and compared the resulting images with that from the bead under ideal, aberration-free imaging condition (Supplementary Fig. 6c,e). The multiplexed method improved signal from this bead by 7.5, almost fully recovering the imaging performance under ideal condition. Finally, deep inside scattering samples where excitation power becomes limited, the multiplexed method would perform better even for sparsely labeled samples because it does not require more power than what is necessary to visualize fluorescent structures, whereas the singlesegment illumination method needs higher excitation power during aberration measurement to compensate for the reduction of NA.

Rapid Adaptive Optical Recovery of Optimal Resolution over Large Volumes

Rapid Adaptive Optical Recovery of Optimal Resolution over Large Volumes SUPPLEMENTARY MATERIAL Rapid Adaptive Optical Recovery of Optimal Resolution over Large Volumes Kai Wang, Dan Milkie, Ankur Saxena, Peter Engerer, Thomas Misgeld, Marianne E. Bronner, Jeff Mumm, and Eric

More information

Nature Neuroscience: doi: /nn Supplementary Figure 1. Optimized Bessel foci for in vivo volume imaging.

Nature Neuroscience: doi: /nn Supplementary Figure 1. Optimized Bessel foci for in vivo volume imaging. Supplementary Figure 1 Optimized Bessel foci for in vivo volume imaging. (a) Images taken by scanning Bessel foci of various NAs, lateral and axial FWHMs: (Left panels) in vivo volume images of YFP + neurites

More information

Nature Methods: doi: /nmeth Supplementary Figure 1. Schematic of 2P-ISIM AO optical setup.

Nature Methods: doi: /nmeth Supplementary Figure 1. Schematic of 2P-ISIM AO optical setup. Supplementary Figure 1 Schematic of 2P-ISIM AO optical setup. Excitation from a femtosecond laser is passed through intensity control and shuttering optics (1/2 λ wave plate, polarizing beam splitting

More information

Adaptive optics two-photon fluorescence microscopy

Adaptive optics two-photon fluorescence microscopy Adaptive optics two-photon fluorescence microscopy Yaopeng Zhou 1, Thomas Bifano 1 and Charles Lin 2 1. Manufacturing Engineering Department, Boston University 15 Saint Mary's Street, Brookline MA, 02446

More information

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy Bi177 Lecture 5 Adding the Third Dimension Wide-field Imaging Point Spread Function Deconvolution Confocal Laser Scanning Microscopy Confocal Aperture Optical aberrations Alternative Scanning Microscopy

More information

Spectral Imaging with the Opterra Multipoint Scanning Confocal

Spectral Imaging with the Opterra Multipoint Scanning Confocal Spectral Imaging with the Opterra Multipoint Scanning Confocal Outline Opterra design overview Scan Modes Light Path Spectral Imaging with Opterra Drosophila larva heart. Opterra Design Overview Supravideo

More information

Martin J. Booth, Delphine Débarre and Alexander Jesacher. Adaptive Optics for

Martin J. Booth, Delphine Débarre and Alexander Jesacher. Adaptive Optics for Martin J. Booth, Delphine Débarre and Alexander Jesacher Adaptive Optics for Over the last decade, researchers have applied adaptive optics a technology that was originally conceived for telescopes to

More information

Shaping light in microscopy:

Shaping light in microscopy: Shaping light in microscopy: Adaptive optical methods and nonconventional beam shapes for enhanced imaging Martí Duocastella planet detector detector sample sample Aberrated wavefront Beamsplitter Adaptive

More information

Supplementary information, Figure S1A-S1H The thickness and the uniformity of the light sheet at different DOFs. By

Supplementary information, Figure S1A-S1H The thickness and the uniformity of the light sheet at different DOFs. By Supplementary information, Figure S1A-S1H The thickness and the uniformity of the light sheet at different DOFs. By imaging FITC-containing solution, the thickness of the light sheet generated by the P3A-DSLM

More information

Aberrations and adaptive optics for biomedical microscopes

Aberrations and adaptive optics for biomedical microscopes Aberrations and adaptive optics for biomedical microscopes Martin Booth Department of Engineering Science And Centre for Neural Circuits and Behaviour University of Oxford Outline Rays, wave fronts and

More information

Fast, high-contrast imaging of animal development with scanned light sheet based structured-illumination microscopy

Fast, high-contrast imaging of animal development with scanned light sheet based structured-illumination microscopy nature methods Fast, high-contrast imaging of animal development with scanned light sheet based structured-illumination microscopy Philipp J Keller, Annette D Schmidt, Anthony Santella, Khaled Khairy,

More information

Study of self-interference incoherent digital holography for the application of retinal imaging

Study of self-interference incoherent digital holography for the application of retinal imaging Study of self-interference incoherent digital holography for the application of retinal imaging Jisoo Hong and Myung K. Kim Department of Physics, University of South Florida, Tampa, FL, US 33620 ABSTRACT

More information

3D light microscopy techniques

3D light microscopy techniques 3D light microscopy techniques The image of a point is a 3D feature In-focus image Out-of-focus image The image of a point is not a point Point Spread Function (PSF) 1D imaging 1 1 2! NA = 0.5! NA 2D imaging

More information

Deep and fast live imaging with two-photon scanned light-sheet microscopy

Deep and fast live imaging with two-photon scanned light-sheet microscopy Nature Methods Deep and fast live imaging with two-photon scanned light-sheet microscopy Thai V Truong, Willy Supatto, Davis S Koos, John M Choi & Scott E Fraser Supplementary Figure 1 Supplementary Figure

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION Optically reconfigurable metasurfaces and photonic devices based on phase change materials S1: Schematic diagram of the experimental setup. A Ti-Sapphire femtosecond laser (Coherent Chameleon Vision S)

More information

1.The Problem LIGHT-LEVEL LEVEL IMAGING. light-level level Cameras. 3. Solutions. 2. Low-light LOW-LIGHT

1.The Problem LIGHT-LEVEL LEVEL IMAGING. light-level level Cameras. 3. Solutions. 2. Low-light LOW-LIGHT LOW-LIGHT LIGHT-LEVEL LEVEL IMAGING 1.The Problem 2. Low-light light-level level Cameras 3. Solutions How Much Light? I. Illumination system: 75 W Xenon Arc (~1mW/nm in visible) 490/10 nm exciter filter

More information

MULTIPHOTON MICROSCOPY. Matyas Molnar Dirk Pacholsky

MULTIPHOTON MICROSCOPY. Matyas Molnar Dirk Pacholsky MULTIPHOTON MICROSCOPY Matyas Molnar Dirk Pacholsky Information Information given here about 2 Photon microscopy were mainly taken from these sources: Background information on 2-Photon microscopy: http://micro.magnet.fsu.edu/primer/techniques/fluorescence/multiphoton/

More information

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D Microscopy Outline 1. Resolution and Simple Optical Microscope 2. Contrast enhancement: Dark field, Fluorescence (Chelsea & Peter), Phase Contrast, DIC 3. Newer Methods: Scanning Tunneling microscopy (STM),

More information

More fancy SPIM, Even fancier SPIM

More fancy SPIM, Even fancier SPIM More fancy SPIM, Even fancier SPIM Last class Light sheet microscopy Fancy SPIM (ispim, dspim, etc ) This class Multi camera SPIM SIM SPIM Bessels d x,y = λ em 2 NA d z = 2 NA λ ex + n(1 cosθ λ em 1 IsoView

More information

Multidimensional Imaging with the Opterra Multipoint Scanning Confocal System

Multidimensional Imaging with the Opterra Multipoint Scanning Confocal System Multidimensional Imaging with the Opterra Multipoint Scanning Confocal System Outline Opterra design overview Light Path Scan Modes Performance Application data Drosophila larva heart. Courtesy of Nikon

More information

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report Introduction and Background Two-photon microscopy is a type of fluorescence microscopy using two-photon excitation. It

More information

Pulse Shaping Application Note

Pulse Shaping Application Note Application Note 8010 Pulse Shaping Application Note Revision 1.0 Boulder Nonlinear Systems, Inc. 450 Courtney Way Lafayette, CO 80026-8878 USA Shaping ultrafast optical pulses with liquid crystal spatial

More information

2. Adaptive Optical Microscopy using Direct Wavefront Sensing 2.1 Introduction In this chapter we will review adaptive optics (AO) in biological

2. Adaptive Optical Microscopy using Direct Wavefront Sensing 2.1 Introduction In this chapter we will review adaptive optics (AO) in biological 2. Adaptive Optical Microscopy using Direct Wavefront Sensing 2.1 Introduction In this chapter we will review adaptive optics (AO) in biological imaging using direct wavefront measurement. Here light from

More information

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1

Spectral phase shaping for high resolution CARS spectroscopy around 3000 cm 1 Spectral phase shaping for high resolution CARS spectroscopy around 3 cm A.C.W. van Rhijn, S. Postma, J.P. Korterik, J.L. Herek, and H.L. Offerhaus Mesa + Research Institute for Nanotechnology, University

More information

FEMTOSMART. Benefits. Features

FEMTOSMART. Benefits. Features FEMTOSMART Extremely large space under the objective For in vivo studies Field upgradability Patented imaging technologies Flexible scanning methods Maximal photon collection Elevated, column-based body

More information

Scanless two-photon excitation of channelrhodopsin-2

Scanless two-photon excitation of channelrhodopsin-2 Nature Methods Scanless two-photon excitation of channelrhodopsin- Eirini Papagiakoumou, Francesca Anselmi, Aurelien Begue, Vincent de Sars, Jesper Glückstad, Ehud Y Isacoff & Valentina Emiliani Supplementary

More information

Dynamic beam shaping with programmable diffractive optics

Dynamic beam shaping with programmable diffractive optics Dynamic beam shaping with programmable diffractive optics Bosanta R. Boruah Dept. of Physics, GU Page 1 Outline of the talk Introduction Holography Programmable diffractive optics Laser scanning confocal

More information

3D light microscopy techniques

3D light microscopy techniques 3D light microscopy techniques The image of a point is a 3D feature In-focus image Out-of-focus image The image of a point is not a point Point Spread Function (PSF) 1D imaging 2D imaging 3D imaging Resolution

More information

Confocal Microscopy. Kristin Jensen

Confocal Microscopy. Kristin Jensen Confocal Microscopy Kristin Jensen 17.11.05 References Cell Biological Applications of Confocal Microscopy, Brian Matsumoto, chapter 1 Studying protein dynamics in living cells,, Jennifer Lippincott-Schwartz

More information

Single-photon excitation of morphology dependent resonance

Single-photon excitation of morphology dependent resonance Single-photon excitation of morphology dependent resonance 3.1 Introduction The examination of morphology dependent resonance (MDR) has been of considerable importance to many fields in optical science.

More information

Bio 407. Applied microscopy. Introduction into light microscopy. José María Mateos. Center for Microscopy and Image Analysis

Bio 407. Applied microscopy. Introduction into light microscopy. José María Mateos. Center for Microscopy and Image Analysis Center for Microscopy and Image Analysis Bio 407 Applied Introduction into light José María Mateos Fundamentals of light Compound microscope Microscope composed of an objective and an additional lens (eyepiece,

More information

Chapter 3 Op,cal Instrumenta,on

Chapter 3 Op,cal Instrumenta,on Imaging by an Op,cal System Change in curvature of wavefronts by a thin lens Chapter 3 Op,cal Instrumenta,on 3-1 Stops, Pupils, and Windows 3-4 The Camera 3-5 Simple Magnifiers and Eyepieces 1. Magnifiers

More information

Dynamic closed-loop system for focus tracking using a spatial light modulator and a deformable membrane mirror

Dynamic closed-loop system for focus tracking using a spatial light modulator and a deformable membrane mirror Dynamic closed-loop system for focus tracking using a spatial light modulator and a deformable membrane mirror Amanda J. Wright, Brett A. Patterson, Simon P. Poland, John M. Girkin Institute of Photonics,

More information

A novel tunable diode laser using volume holographic gratings

A novel tunable diode laser using volume holographic gratings A novel tunable diode laser using volume holographic gratings Christophe Moser *, Lawrence Ho and Frank Havermeyer Ondax, Inc. 85 E. Duarte Road, Monrovia, CA 9116, USA ABSTRACT We have developed a self-aligned

More information

Confocal Microscopy and Related Techniques

Confocal Microscopy and Related Techniques Confocal Microscopy and Related Techniques Chau-Hwang Lee Associate Research Fellow Research Center for Applied Sciences, Academia Sinica 128 Sec. 2, Academia Rd., Nankang, Taipei 11529, Taiwan E-mail:

More information

Monitoring Neural Activity with Bioluminescence during Natural Behavior E. A. Naumann*, A. R. Kampff*, D. A. Prober, A. F. Schier and F.

Monitoring Neural Activity with Bioluminescence during Natural Behavior E. A. Naumann*, A. R. Kampff*, D. A. Prober, A. F. Schier and F. Monitoring Neural Activity with Bioluminescence during Natural Behavior E. A. Naumann*, A. R. Kampff*, D. A. Prober, A. F. Schier and F. Engert Supplementary Figure 1 Neuroluminescence in zebrafish: mechanism

More information

Supplementary Figure 1

Supplementary Figure 1 Supplementary Figure 1 Processing pipeline for laser scanning microscopy HDR imaging. The processing pipeline consists of five distinct phases. Images are first acquired after determining the appropriate

More information

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name: EE119 Introduction to Optical Engineering Spring 2003 Final Exam Name: SID: CLOSED BOOK. THREE 8 1/2 X 11 SHEETS OF NOTES, AND SCIENTIFIC POCKET CALCULATOR PERMITTED. TIME ALLOTTED: 180 MINUTES Fundamental

More information

Basics of confocal imaging (part I)

Basics of confocal imaging (part I) Basics of confocal imaging (part I) Swiss Institute of Technology (EPFL) Faculty of Life Sciences Head of BIOIMAGING AND OPTICS BIOP arne.seitz@epfl.ch Lateral resolution BioImaging &Optics Platform Light

More information

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Confocal Imaging Through Scattering Media with a Volume Holographic Filter Confocal Imaging Through Scattering Media with a Volume Holographic Filter Michal Balberg +, George Barbastathis*, Sergio Fantini % and David J. Brady University of Illinois at Urbana-Champaign, Urbana,

More information

Nature Methods: doi: /nmeth Supplementary Figure 1. Comparison of HySP and linear unmixing under different signal-to-noise ratios (SNRs).

Nature Methods: doi: /nmeth Supplementary Figure 1. Comparison of HySP and linear unmixing under different signal-to-noise ratios (SNRs). Supplementary Figure 1 Comparison of HySP and linear unmixing under different signal-to-noise ratios (SNRs). (a) TrueColor images of 32 channel datasets of zebrafish labeled with H2B-Cerulean, kdrl:egfp,

More information

Supplementary Information

Supplementary Information Supplementary Information Simultaneous whole- animal 3D- imaging of neuronal activity using light field microscopy Robert Prevedel 1-3,10, Young- Gyu Yoon 4,5,10, Maximilian Hoffmann,1-3, Nikita Pak 5,6,

More information

Introduction to Optofluidics. 1-5 June Use of spatial light modulators (SLM) for beam shaping and optical tweezers

Introduction to Optofluidics. 1-5 June Use of spatial light modulators (SLM) for beam shaping and optical tweezers 2037-4 Introduction to Optofluidics 1-5 June 2009 Use of spatial light modulators (SLM) for beam shaping and optical tweezers M. Padgett University of Glasgow U.K. Use of spatial light modulators (SLM)

More information

Adaptive Optics for LIGO

Adaptive Optics for LIGO Adaptive Optics for LIGO Justin Mansell Ginzton Laboratory LIGO-G990022-39-M Motivation Wavefront Sensor Outline Characterization Enhancements Modeling Projections Adaptive Optics Results Effects of Thermal

More information

Microscope anatomy, image formation and resolution

Microscope anatomy, image formation and resolution Microscope anatomy, image formation and resolution Ian Dobbie Buy this book for your lab: D.B. Murphy, "Fundamentals of light microscopy and electronic imaging", ISBN 0-471-25391-X Visit these websites:

More information

MALA MATEEN. 1. Abstract

MALA MATEEN. 1. Abstract IMPROVING THE SENSITIVITY OF ASTRONOMICAL CURVATURE WAVEFRONT SENSOR USING DUAL-STROKE CURVATURE: A SYNOPSIS MALA MATEEN 1. Abstract Below I present a synopsis of the paper: Improving the Sensitivity of

More information

12.4 Alignment and Manufacturing Tolerances for Segmented Telescopes

12.4 Alignment and Manufacturing Tolerances for Segmented Telescopes 330 Chapter 12 12.4 Alignment and Manufacturing Tolerances for Segmented Telescopes Similar to the JWST, the next-generation large-aperture space telescope for optical and UV astronomy has a segmented

More information

Confocal Microscopy. (Increasing contrast and resolu6on using op6cal sec6oning) Lecture 7. November 2017

Confocal Microscopy. (Increasing contrast and resolu6on using op6cal sec6oning) Lecture 7. November 2017 Confocal Microscopy (Increasing contrast and resolu6on using op6cal sec6oning) Lecture 7 November 2017 3 Flavours of Microscope Confocal Laser Scanning Problem: Out of Focus Light Spinning disc 2-Photon

More information

Chapter 3 Op+cal Instrumenta+on

Chapter 3 Op+cal Instrumenta+on Chapter 3 Op+cal Instrumenta+on 3-1 Stops, Pupils, and Windows 3-4 The Camera 3-5 Simple Magnifiers and Eyepieces 3-6 Microscopes 3-7 Telescopes Today (2011-09-22) 1. Magnifiers 2. Camera 3. Resolution

More information

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph

Life Science Instrumentation. New Generation. Light Sheet Fluorescence Microscope. Alph Life Science Instrumentation Light Sheet Fluorescence Microscope New Generation Alph Modular Light Sheet Microscope Alpha 3 is a new generation of light sheet fluorescence microscope addressing the needs

More information

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy Qiyuan Song (M2) and Aoi Nakamura (B4) Abstracts: We theoretically and experimentally

More information

The Nature of Light. Light and Energy

The Nature of Light. Light and Energy The Nature of Light Light and Energy - dependent on energy from the sun, directly and indirectly - solar energy intimately associated with existence of life -light absorption: dissipate as heat emitted

More information

In Vivo Two-Photon Laser Scanning Microscopy with Concurrent Plasma- Mediated Ablation

In Vivo Two-Photon Laser Scanning Microscopy with Concurrent Plasma- Mediated Ablation 3 In Vivo Two-Photon Laser Scanning Microscopy with Concurrent Plasma- Mediated Ablation Principles and Hardware Realization Philbert S. Tsai and David Kleinfeld Contents 3.1 Introduction... 61 3. Overview...

More information

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:

EE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name: EE119 Introduction to Optical Engineering Fall 2009 Final Exam Name: SID: CLOSED BOOK. THREE 8 1/2 X 11 SHEETS OF NOTES, AND SCIENTIFIC POCKET CALCULATOR PERMITTED. TIME ALLOTTED: 180 MINUTES Fundamental

More information

1.6 Beam Wander vs. Image Jitter

1.6 Beam Wander vs. Image Jitter 8 Chapter 1 1.6 Beam Wander vs. Image Jitter It is common at this point to look at beam wander and image jitter and ask what differentiates them. Consider a cooperative optical communication system that

More information

NIH Public Access Author Manuscript Opt Lett. Author manuscript; available in PMC 2010 August 9.

NIH Public Access Author Manuscript Opt Lett. Author manuscript; available in PMC 2010 August 9. NIH Public Access Author Manuscript Published in final edited form as: Opt Lett. 2010 January 1; 35(1): 67 69. Autoconfocal transmission microscopy based on two-photon induced photocurrent of Si photodiodes

More information

Chapter Ray and Wave Optics

Chapter Ray and Wave Optics 109 Chapter Ray and Wave Optics 1. An astronomical telescope has a large aperture to [2002] reduce spherical aberration have high resolution increase span of observation have low dispersion. 2. If two

More information

GEOMETRICAL OPTICS AND OPTICAL DESIGN

GEOMETRICAL OPTICS AND OPTICAL DESIGN GEOMETRICAL OPTICS AND OPTICAL DESIGN Pantazis Mouroulis Associate Professor Center for Imaging Science Rochester Institute of Technology John Macdonald Senior Lecturer Physics Department University of

More information

Leica TCS SP8 Quick Start Guide

Leica TCS SP8 Quick Start Guide Leica TCS SP8 Quick Start Guide Leica TCS SP8 System Overview Start-Up Procedure 1. Turn on the CTR Control Box, Fluorescent Light for the microscope stand. 2. Turn on the Scanner Power (1) on the front

More information

Final Exam, 150 points PMB 185: Techniques in Light Microscopy

Final Exam, 150 points PMB 185: Techniques in Light Microscopy Final Exam, 150 points Name PMB 185: Techniques in Light Microscopy Point value is in parentheses at the end of each question. Note: GFP = green fluorescent protein ; CFP = cyan fluorescent protein ; YFP

More information

Towards 3-Dimensional and time sequenced (4D) live cell imaging

Towards 3-Dimensional and time sequenced (4D) live cell imaging Towards 3-Dimensional and time sequenced (4D) live cell imaging Colloquium presented by Heather Campbell Supervisor: Alan Greenaway (Waves and Fields Group) In collaboration with the HW Nano-Optics Group;

More information

High resolution extended depth of field microscopy using wavefront coding

High resolution extended depth of field microscopy using wavefront coding High resolution extended depth of field microscopy using wavefront coding Matthew R. Arnison *, Peter Török #, Colin J. R. Sheppard *, W. T. Cathey +, Edward R. Dowski, Jr. +, Carol J. Cogswell *+ * Physical

More information

Introduction to light microscopy

Introduction to light microscopy Center for Microscopy and Image Anaylsis Introduction to light microscopy Basic concepts of imaging with light Urs Ziegler ziegler@zmb.uzh.ch Light interacting with matter Absorbtion Refraction Diffraction

More information

BASICS OF CONFOCAL IMAGING (PART I)

BASICS OF CONFOCAL IMAGING (PART I) BASICS OF CONFOCAL IMAGING (PART I) INTERNAL COURSE 2012 LIGHT MICROSCOPY Lateral resolution Transmission Fluorescence d min 1.22 NA obj NA cond 0 0 rairy 0.61 NAobj Ernst Abbe Lord Rayleigh Depth of field

More information

Adaptive optimisation of illumination beam profiles in fluorescence microscopy

Adaptive optimisation of illumination beam profiles in fluorescence microscopy Adaptive optimisation of illumination beam profiles in fluorescence microscopy T. J. Mitchell a, C. D. Saunter a, W. O Nions a, J. M. Girkin a, G. D. Love a a Centre for Advanced nstrumentation & Biophysical

More information

Introduction to light microscopy

Introduction to light microscopy Center for Microscopy and Image Anaylsis Introduction to light Imaging with light / Overview of techniques Urs Ziegler ziegler@zmb.uzh.ch Light interacting with matter Absorbtion Refraction Diffraction

More information

GPI INSTRUMENT PAGES

GPI INSTRUMENT PAGES GPI INSTRUMENT PAGES This document presents a snapshot of the GPI Instrument web pages as of the date of the call for letters of intent. Please consult the GPI web pages themselves for up to the minute

More information

ADVANCED METHODS FOR CONFOCAL MICROSCOPY II. Jean-Yves Chatton Sept. 2006

ADVANCED METHODS FOR CONFOCAL MICROSCOPY II. Jean-Yves Chatton Sept. 2006 ADVANCED METHODS FOR CONFOCAL MICROSCOPY II Jean-Yves Chatton Sept. 2006 Workshop outline Confocal microscopy of living cells and tissues X-Z scanning Time series Bleach: FRAP, photoactivation Emission

More information

Very short introduction to light microscopy and digital imaging

Very short introduction to light microscopy and digital imaging Very short introduction to light microscopy and digital imaging Hernan G. Garcia August 1, 2005 1 Light Microscopy Basics In this section we will briefly describe the basic principles of operation and

More information

STORM/ PALM ANSWER KEY

STORM/ PALM ANSWER KEY STORM/ PALM ANSWER KEY Phys598BP Spring 2016 University of Illinois at Urbana-Champaign Questions for Lab Report 1. How do you define a resolution in STORM imaging? If you are given a STORM setup, how

More information

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy, KTH Applied Physics Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy, 2009-06-05, 8-13, FB51 Allowed aids: Compendium Imaging Physics (handed out) Compendium Light Microscopy

More information

BEAM SHAPING OPTICS TO IMPROVE HOLOGRAPHIC AND INTERFEROMETRIC NANOMANUFACTURING TECHNIQUES Paper N405 ABSTRACT

BEAM SHAPING OPTICS TO IMPROVE HOLOGRAPHIC AND INTERFEROMETRIC NANOMANUFACTURING TECHNIQUES Paper N405 ABSTRACT BEAM SHAPING OPTICS TO IMPROVE HOLOGRAPHIC AND INTERFEROMETRIC NANOMANUFACTURING TECHNIQUES Paper N5 Alexander Laskin, Vadim Laskin AdlOptica GmbH, Rudower Chaussee 9, 89 Berlin, Germany ABSTRACT Abstract

More information

Improving the Collection Efficiency of Raman Scattering

Improving the Collection Efficiency of Raman Scattering PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution

More information

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:

Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature: Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: PID: Signature: CLOSED BOOK. TWO 8 1/2 X 11 SHEET OF NOTES (double sided is allowed), AND SCIENTIFIC POCKET CALCULATOR

More information

Opterra. Multipoint Scanning Confocal Microscope. Innovation with Integrity. Cell-Friendly, High-Speed, High-Resolution Imaging

Opterra. Multipoint Scanning Confocal Microscope. Innovation with Integrity. Cell-Friendly, High-Speed, High-Resolution Imaging Opterra Multipoint Scanning Confocal Microscope Cell-Friendly, High-Speed, High-Resolution Imaging Innovation with Integrity Fluorescence Microscopy Opterra Multipoint Scanning Confocal Microscope Superior

More information

Flatness of Dichroic Beamsplitters Affects Focus and Image Quality

Flatness of Dichroic Beamsplitters Affects Focus and Image Quality Flatness of Dichroic Beamsplitters Affects Focus and Image Quality Flatness of Dichroic Beamsplitters Affects Focus and Image Quality 1. Introduction Even though fluorescence microscopy has become a routine

More information

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember

Optical Components for Laser Applications. Günter Toesko - Laserseminar BLZ im Dezember Günter Toesko - Laserseminar BLZ im Dezember 2009 1 Aberrations An optical aberration is a distortion in the image formed by an optical system compared to the original. It can arise for a number of reasons

More information

Nikon Instruments Europe

Nikon Instruments Europe Nikon Instruments Europe Recommendations for N-SIM sample preparation and image reconstruction Dear customer, We hope you find the following guidelines useful in order to get the best performance out of

More information

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO TRAINING MANUAL Multiphoton Microscopy LSM 510 META-NLO September 2010 Multiphoton Microscopy Training Manual Multiphoton microscopy is only available on the LSM 510 META-NLO system. This system is equipped

More information

Εισαγωγική στην Οπτική Απεικόνιση

Εισαγωγική στην Οπτική Απεικόνιση Εισαγωγική στην Οπτική Απεικόνιση Δημήτριος Τζεράνης, Ph.D. Εμβιομηχανική και Βιοϊατρική Τεχνολογία Τμήμα Μηχανολόγων Μηχανικών Ε.Μ.Π. Χειμερινό Εξάμηνο 2015 Light: A type of EM Radiation EM radiation:

More information

A broadband achromatic metalens for focusing and imaging in the visible

A broadband achromatic metalens for focusing and imaging in the visible SUPPLEMENTARY INFORMATION Articles https://doi.org/10.1038/s41565-017-0034-6 In the format provided by the authors and unedited. A broadband achromatic metalens for focusing and imaging in the visible

More information

Dynamic Confocal Imaging of Living Brain. Advantages and risks of multiphoton microscopy in physiology

Dynamic Confocal Imaging of Living Brain. Advantages and risks of multiphoton microscopy in physiology Dynamic Confocal Imaging of Living Brain Advantages and risks of multiphoton microscopy in physiology Confocal laser scanning microscopy In conventional optical microscopy focused and out-offocus light

More information

Micropulse Duty Cycle. # of eyes (20 ms) Total spots (200 ms)

Micropulse Duty Cycle. # of eyes (20 ms) Total spots (200 ms) Micropulse Duty Cycle Total spots (2 ms) # of eyes (2 ms) Total spots (2 ms) % 269 44 3 47% 9 4 4 25% 3 5 4 4 5% 2 4 3 5 2% 5 2 NA NA 9% 2 4 6% NA NA 57 2 5% 4 5 6 3 3% 39 5 35 5 # of eyes (2 ms) Supplemental

More information

Imaging Introduction. September 24, 2010

Imaging Introduction. September 24, 2010 Imaging Introduction September 24, 2010 What is a microscope? Merriam-Webster: an optical instrument consisting of a lens or combination of lenses for making enlarged images of minute objects; especially:

More information

BEAM HALO OBSERVATION BY CORONAGRAPH

BEAM HALO OBSERVATION BY CORONAGRAPH BEAM HALO OBSERVATION BY CORONAGRAPH T. Mitsuhashi, KEK, TSUKUBA, Japan Abstract We have developed a coronagraph for the observation of the beam halo surrounding a beam. An opaque disk is set in the beam

More information

5/4/2015 INTRODUCTION TO LIGHT MICROSCOPY. Urs Ziegler MICROSCOPY WITH LIGHT. Image formation in a nutshell. Overview of techniques

5/4/2015 INTRODUCTION TO LIGHT MICROSCOPY. Urs Ziegler MICROSCOPY WITH LIGHT. Image formation in a nutshell. Overview of techniques INTRODUCTION TO LIGHT MICROSCOPY Urs Ziegler ziegler@zmb.uzh.ch MICROSCOPY WITH LIGHT INTRODUCTION TO LIGHT MICROSCOPY Image formation in a nutshell Overview of techniques Widefield microscopy Resolution

More information

Introduction to Light Microscopy. (Image: T. Wittman, Scripps)

Introduction to Light Microscopy. (Image: T. Wittman, Scripps) Introduction to Light Microscopy (Image: T. Wittman, Scripps) The Light Microscope Four centuries of history Vibrant current development One of the most widely used research tools A. Khodjakov et al. Major

More information

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin film is characterized by using an optical profiler (Bruker ContourGT InMotion). Inset: 3D optical

More information

MODULAR ADAPTIVE OPTICS TESTBED FOR THE NPOI

MODULAR ADAPTIVE OPTICS TESTBED FOR THE NPOI MODULAR ADAPTIVE OPTICS TESTBED FOR THE NPOI Jonathan R. Andrews, Ty Martinez, Christopher C. Wilcox, Sergio R. Restaino Naval Research Laboratory, Remote Sensing Division, Code 7216, 4555 Overlook Ave

More information

Potential benefits of freeform optics for the ELT instruments. J. Kosmalski

Potential benefits of freeform optics for the ELT instruments. J. Kosmalski Potential benefits of freeform optics for the ELT instruments J. Kosmalski Freeform Days, 12-13 th October 2017 Summary Introduction to E-ELT intruments Freeform design for MAORY LGS Free form design for

More information

Heisenberg) relation applied to space and transverse wavevector

Heisenberg) relation applied to space and transverse wavevector 2. Optical Microscopy 2.1 Principles A microscope is in principle nothing else than a simple lens system for magnifying small objects. The first lens, called the objective, has a short focal length (a

More information

Applications of Adaptive Optics in Fluorescence Microscopy and Ophthalmology

Applications of Adaptive Optics in Fluorescence Microscopy and Ophthalmology Applications of Adaptive Optics in Fluorescence Microscopy and Ophthalmology Audrius JASAITIS Imagine Optic (Orsay, France) Application Specialist Microscopy ajasaitis@imagine-optic.com Imagine Optic -

More information

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005 Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev Why use confocal microscopy? Principles of the laser scanning confocal microscope. Image resolution. Manipulating the

More information

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI) Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI) Liang-Chia Chen 1#, Chao-Nan Chen 1 and Yi-Wei Chang 1 1. Institute of Automation Technology,

More information

Enhancement of the lateral resolution and the image quality in a line-scanning tomographic optical microscope

Enhancement of the lateral resolution and the image quality in a line-scanning tomographic optical microscope Summary of the PhD thesis Enhancement of the lateral resolution and the image quality in a line-scanning tomographic optical microscope Author: Dudás, László Supervisors: Prof. Dr. Szabó, Gábor and Dr.

More information

Femtosecond laser microfabrication in. Prof. Dr. Cleber R. Mendonca

Femtosecond laser microfabrication in. Prof. Dr. Cleber R. Mendonca Femtosecond laser microfabrication in polymers Prof. Dr. Cleber R. Mendonca laser microfabrication focus laser beam on material s surface laser microfabrication laser microfabrication laser microfabrication

More information

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal

Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal Digital Camera Technologies for Scientific Bio-Imaging. Part 2: Sampling and Signal Yashvinder Sabharwal, 1 James Joubert 2 and Deepak Sharma 2 1. Solexis Advisors LLC, Austin, TX, USA 2. Photometrics

More information

Travel to New Dimensions- LSM 880. The Resolution of a Microscope is limited. The Resolution of a Microscope is limited. Image. Image. Object.

Travel to New Dimensions- LSM 880. The Resolution of a Microscope is limited. The Resolution of a Microscope is limited. Image. Image. Object. Travel to New Dimensions- LSM 880 LSM 880: The Power of Sensitivity Our Latest Member of the LSM 880 with GaAsP Detectors Sensitivity, and Ease of Use Innovative High-End Laser Scanning Microscopes from

More information

J-KAREN-P Session 1, 10:00 10:

J-KAREN-P Session 1, 10:00 10: J-KAREN-P 2018 Session 1, 10:00 10:25 2018 5 8 Outline Introduction Capabilities of J-KAREN-P facility Optical architecture Status and implementation of J-KAREN-P facility Amplification performance Recompression

More information

Modulation Transfer Function

Modulation Transfer Function Modulation Transfer Function The Modulation Transfer Function (MTF) is a useful tool in system evaluation. t describes if, and how well, different spatial frequencies are transferred from object to image.

More information