1 UPDATED - February 09 The technical documentation of the venue that includ stage, sound or lighting is not list as a contract. Contact the technical department for an update on this document. General Informations Seating seating capacity for booking house seats parterre (including house seats and orchestra pit) Corbeille Balcon Total Removable seats (one by one) House row, seat number Q à 0 / to 0 " R 5 à 0 / 5 to 0 " S 5 à / 5 to " K, L, M, N, O, P à 8 / to 8 Orchestra pits pit for 55 musicians rows AA, BB and CC are removed. total: 58 seats Capacity for booking 377 House dimensions from house curtain to last row of the house,6m 80'-3" from house curtain to last row in balcony 8,9m 9'-6" From Corbeille edge to Cyclorama (Projection) 3,m 0'6" Artist entrance 00 St.Urbain street Loading dock 0 St.Urbain street At street level, the stage of the theater is located two levels above the street. Sets, costumes and properties have to be transported to the stage by elevator. Loading platform dimensions width 9,58 m 3'-5'' length 3, m 3'-0'' height 3,05 m 0'-0'' height of platform,09 m 3'-7'' Two trailers (without tractors) can be parked inside the garage with doors closed. Elevator Maximum allowed weight 6,8 T lbs width 3,8 m ''-5' length 7,77 m 5'-6'' height 3,8 m '-5'' Elevator door width,97 m 9'-9'' length 3,00 m 9'-0'' all objects must not exceed 3 feet (7,0 m) Chain Hoist for roadcases SR (Unstacking ) 000 Kg 00 lbs Page
2 Production offices Production offices - Level 6, stage level located backstage, 3 people telephone : Dressing rooms DRESSING ROOMS - Level 6, stage level Make-up room or dressing room persons Loge A Loge B Loge C Loge D Make-up room DRESSING ROOMS - Level 5 (shared with F) (shared with E) (shared with H) person toilet - shower (shared with G) person toilet - shower (shared with K) (shared with J) person toilet - shower Musician's room Loge E Loge F Loge G Loge H Loge J Loge K Loge L Loge M Room of honour width 6,0 m 0'- '' length 5,6 m 7'-'' (69 persons) - toilets and showers LARGE DRESSING ROOM - Level 7 DRESSING ROOMS - Level 5 9, m x 3,6 m 3' x ' NB: wardrobe employees are members of IATSE local Wardrobe room sink washing machine dryer machine flat iron Jiffy steamer quick change 8' x 8' Rehearsal rooms available upon request Page
3 Stage Stage description and dimensions General rule It is stricly forbidden to screw, nail or staple into the stage floor Production or visiting company must find alternatives ways to secure and anchor their stage equipment or scenery. In exceptional circumstances, anchors might be permitted upon prior arrangement and autorisation, in this eventuality, cost will apply. Stage floor wooden stage floor covered with linoleum (battleship), except playing area. Allowed load on the stage floor kg / m² lbs/pi² pound/foot² Proscenium height 0,97 m 3'- '' Proscenium opening maximum height 8,3 m 7'- 0'' minimum height 5,7 m 8'- 0'' maximum width 7,00 m 55'- 9'' minimum width 9,0 m 9'- 7'' Stage dimensions Total width 6,8 m 53'- 7'' from center line to S.R. wall 3,39 m 76'- 9'' from center line to S.L. wall 3, m 76'- 0'' Total depth (excluding pit) 7,86 m 58'- 7'' from house curtain to back wall 6,3 m 53'- 6'' from house curtain to orchestra pit,55 m 5'- '' from house curtain to apron 6,8 m '- '' Height from stage floor to grid 5,90 m 85'- 0'' clearance under fly gallery SR 8, m 7'- 0'' clearance under fly gallery SL 8, m 7'- 0'' Wing space, stage right width,05 m 6'-0'' length,9 m 0'- 0'' Wing space, stage left width 3,7 m 5'-0'' length,88 m '- 3'' Rigging system Fly system : Double purchase counterweight system * operated from S.R. fly gallery pipe's length,9 m 75'- 3'' number of sets * 7 * maximum loading capacity 57 kg 0 lbs * Lineset #8 is used for the fixed movie screen Motorized side pipe : maximum loading capacity 70 Kg 600 lbs Motorized pipe in front of the procenium pipe's length,63 m 8' * maximum loading capacity 5 Kg 00 lbs * see the line plot for house hang. Main Power (08V) and Chain Hoist cam-lock, at grid level 60 A Subject to availability and billable: Chain hoists T double-brake, 00',,8 m/min ChainMaster BGV D8 Chain Hoist controller Chain Hoist to lift video projector at Corbeille edge ChainMaster 50 Kg fixed Page
4 Stage masking House curtain Fabric (yellow, orange and brown) with center opening. operated from stage right. Fly type (up and down) Stage curtains (black velvet) legs standard opening 3, m '- 0'' * see the house hang sets of legs 6 width,7 m 5'- 6'' length 0,67 m 35'- 0'' borders width,3 m 70'- 0'' height,7 m 5'- 6'' set of legs for cyclorama width,7 m 5'- 6'' height 0,67 m 35'- 0'' full back drops 5 width,8 m 70'- 0'' height 0,67 m 35'- 0'' half backing (traveler) width 0,67 m 35'- 0'' height 0,67 m 35'- 0'' Germans (side curtains) 6 width,7 m 5'- 6'' height 0,67 m 35'- 0'' Scrims white width,3 m 70'- 0'' height 0, m 33'- 6' black width,3 m 70'- 0'' height 0,67 m 35'- 0'' Cyclorama plastic, cream colored width,3 m 70'- 0'' height,9 m 0'- 0'' Stage manager's desk Desk located S.R. only, includes paging microphone Orchestra equipment musician's chair stage pit stool 0 utility chair music stands stands lights Conductor's podium 85 black wood 30" 50 Pianos (piano tuning charges will apply) Steinway 9' D - New York Page
5 Risers plateform 3, x, m ' x 8' 8, x, m ' x ' leg 6 03 mm 8" 6 06 mm 6" 60 mm " riser's straircase 5 5 riser's wheel 3 steps steps dress kit 8 03 x 876 mm 8'' x 6' 8 06 x 876 mm 6'' x 6' 8 60 x 876 mm '' x 6' Ground support systems bases+pin " x " - 3 holes on a dolly adjustables 7'-' horizontal adjustable 6'-0' vertical black curtain 8' x 8' Tables ' lenght 6' 8' Lifts (battery, ac) Genie AWP-36S Step ladders height : 6' 8' Louisville-Werner 0' ' ladder 0' Dance floor Harlequin Cascade 0 9' x 6'-7" rolls Black drum carpet ' x 8' 8' x 8' Carpet Page
6 Lighting Touring companies (0 / 08 volts) located stage left * connection possibility when available 00 A 00 A Follows spots follow spot Robert Juliat Aramis HMI.5 kw Stage lighting control console Strand Light Palette VL located behind the first balcony. console Strand Light Palette VL located stage right dimmer = circuit dimmers 68 Strand C- /. Kw dimmers Strand C- / 6 Kw Electronic soft patch Catwalk (FOH) Fixed equipment ETC - Source Four F.O.H 6 # w # st 750 w zoom 5 x 30 # nd 750 w Torm doors w ETC - S w Scoop bar 8 Iris Kw worklights 3 ETC PAR 575 w bodies Source four 575 w lenses available: ETC Strand projectors 6 5 x w zoom SL 3 x w 0 fresnel 8" 8 x 6 Kw 0 fresnel 6" 5 x 59 Kw Altman projectors 8 Par 6 Kw Bulbs available: Wide - Medium - Narrow - Very Narrow 0 Par ACL (simple) ground row ( x circuits) Aurora '-'' - ( 30 mm ) Kw Gobo holder 0 type A ETC 0 type B 0 Strand type B Iris floor base lighting ladders Roscolux color filters Mobile Equipment Lighting accessories ETC Strand simple 30" x 5' Page
7 Sound Clause 9. of the contract: The Théâtre Maisonneuve is located above the théâtre Jean-Duceppe. The TENANT agrees to comply to the satisfaction of the SOCIETY the volume of his license at Théâtre Maisonneuve to a maximum of ninety-six (96) dbc. Touring companies (0 / 08 volts) located stage left 00 A Mixing console Audio mixing position Center, last rows(q,r,s) at Parterre level usable width x depth 9" x 0",3m x,59m mixing digital audio board SD-0 opticon DIGICO (CORE v) 56 IN / 56 OUT (8 Analog + 8 AES/EBU) SD-RACK Available from September to may : SD-9 DIGICO (CORE v) 0 In / 6 OUT D-Rack 50 balanced lines (mobile on stage) 6 balanced lines (stage left) multi-patch patch box House speaker system Center sub-bass speaker (fixed) 600-HP Floor sub-bass speaker L + R (fixed) 650-P Top speaker L + R (fixed) 8 Meyer MINA Floor speaker L + R (fixed) + UPQ-P / UPQ-P Front fill speaker 6 UP-XP Corbeille delay speaker (fixed) EAW JF-80 Balcon delay speaker (fixed) Meyer UPJ-P main system processor (fixed) Meyer Galileo 66 Stage monitor system monitors mix including: 8 passive speaker 6 EAW SM-00 equalizer Klark teknik DN360 amplifier 7 QSC MX500A speaker for side fill Meyer MSL- P Playback CD player SONY CDP-D Egalizer Klark teknik DN Page
8 Microphones 3 MX393 7 SM-57 7 SM-58 SM-58S Switch on/off Shure SM-8 SM-87 SM-9 Beta-98 Beta 5 KM-8 Neumann TLM-93 6 E60 with percussion clip MD- Sennheiser MD- 3 MKH-0 MKH-60 with shockmount clip C- ULS with shockmount clip AKG C-B with shockmount clip C-5 PZM 30RB Crown PCC 60 Goose neck 8" 3 LBB00 active Klark teknik 6 DN-00 3 Radial Pro DI (passive) long with boom small with boom long with boom small with boom with small boom table stand Communications (digital) fixed stations located in the theater CLEAR COM HelixNet stage manager desk, lighting booth, audio rack Beltpack 7 CLEAR-COM HBP-X Permanent beltpack 3 CLEAR-COM HBP-X SR Follow spot, SL Follow spot, loading gallery desktop station with speaker CLEAR-COM HKB-X Permanent desktop station with speaker CLEAR-COM HKB-X Lighting console, Remote console, Prod room, Pin-rail Guest inputs A, B, C, D Wireless intercom system (digital) wireless intercom system (Transmit) FreeSpeak II base CLEARCOM belt pack (Receiver) 8, Ghz Hearing-impaired system DECADE 89,9 FM Projection vidéo Plateform for video projector (Corbeille edge) 300 lbs - 35 Kg CMU offset center 36" 30" depth x 36" Large Page
9 Movie / Cinema Air conditioned projection booth, equipped for 35 mm film. Analog projector Century analog projector KELMAR reverse scanning laser reading system Digital projector digital projector Solara 30 Fixed CHRISTIE high brightness - lense,8-3,0: Fixed digital console Show store DSS00 Fixed DOLBY digital converter DMA8 Fixed automate interface INTEG Jnior 30 Fixed cinema scaler GEFEN Pro Fixed Installed with motorized winch on line set # 8 Projection screen height 6,5 m 0'- 6'' width,80 m '-'' Audio surround system sub-bass speaker* 650P Meyer L/C/R 3 CQ-P surround 6 OUTLINE MOVIE FX 0 Processing XILICA XP 8080 Dolby sound system CP 00 amplification * parts of the existing P.A. house system Page
THÉÂTRE MAISONNEUVE. UPDATED - October 2017
UPDATED - October 2017 The technical documentation of the venue that includ stage, sound or lighting is not list as a contract. Contact the technical department for an update on this document. General
More informationTHÉÂTRE JEAN-DUCEPPE
Updated - October 207 The technical documentation of the venue that include stage, sound or lighting equipment is not part of the contract. Contact the technical department for an update on this Informations
More informationTHÉÂTRE JEAN-DUCEPPE
Updated - February 08 The technical documentation of the venue that include stage, sound or lighting equipment is not part of the contract. Contact the technical department for an update on this Informations
More informationSALLE WILFRID-PELLETIER
UPDATED - September 07 The technical documentation of the venue that include stage, sound or lighting equipment is not part of the contract. Contact the technical department for an update on this document.
More informationJeanne and Peter Lougheed Performing Arts Centre
Theatre Technical Specifications Seating Capacity: 584 Seats Maximum 573 with basic holds (7 seats removed for sound console, 4 FOH Holds) (Space for sound console at the back of the orchestra level is
More informationJockey Club Auditorium - Technical Information
Jockey Club Auditorium - Technical Information General Set-up Jockey Club Auditorium operates on a bare-walls touring policy. That is, all equipment is normally setup and struck within the booking period.
More informationJockey Club Auditorium - Technical Information
Jockey Club Auditorium - Technical Information General Set-up Jockey Club Auditorium operates on a bare-walls touring policy. That is, all equipment is normally set-up and struck within the booking period.
More informationFor more information please contact Bob Luffman at Ext or by at
SOUND INFORMATION For more information please contact Bob Luffman at 519.578.5660 Ext. 5235 or by email at bluffman@centreinthesquare.com INDEX MAIN SOUND SYSTEM Page 1 CENTER CLUSTER 1 ON-STAGE SOUND
More informationFRONT HOUSE AND BACKSTAGE
Technical Rider FRONT HOUSE AND BACKSTAGE - The Cinema-Theatre is equipped for cinema, theatre, music, dance and conferences. - It has a seating capacity of 219, 3 being suitable for wheelchairs. - Lift
More informationREPERTORY THEATRE HOSTOS CENTER FOR THE ARTS & CULTURE
450 Grand Concourse Bronx, NY 10451 Box Office: 718.518.4455 Production Office: 718.518.6635 Production Office FAX: 718.518.6794 Administrative Office: 718.518.6700 THEATER STAFF Director College Asst.
More informationTECHNICAL RIDER OCTOBER 2015
TECHNICAL RIDER OCTOBER 2015 1004 St-Catherine Est, Montréal, Québec, H2L 2G2, Canada Tel.: 514-845-3524 TABLE OF CONTENTS Address Parking and loading dock Stage Stage curtains Dressing rooms Truss and
More informationTECHNICAL RIDER SALA BARTS BARCELONA ARTS ON STAGE. BARTS is a venue located at Barcelona city centre where most important theatres are.
TECHNICAL RIDER SALA BARTS BARCELONA ARTS ON STAGE BARTS is a venue located at Barcelona city centre where most important theatres are. BARTS Avda. Paral.lel, 62 08001 BARCELONA http://www.barts.cat STAGE
More informationHodgson Concert Hall Technical Information Packet 2017
General Information: Location: Hodgson Concert Hall is located in the Performing Arts Center building at the Performing and Visual Arts Complex off River Road in Athens, GA. River Road can be accessed
More informationDuncan Theatre Technical Specifications 6/16. Contact: Josh Schneider, Technical Director, , FAX
AT PALM BEACH STATE COLLEGE 4200 Congress Avenue, MS 62 Lake Worth, FL 33461 Josh Schneider, Technical Director 561-868-3313, Fax 561-868-3317 schneidj@palmbeachstate.edu Duncan Theatre Technical Specifications
More informationTechnical Specification 2017
Technical Technical For further information please contact Millfield.Technical@Enfield.gov.uk Technical Department:0208 887 7315 www.millfieldtheatre.co.uk,, Updated: February 2016 Technical Seating Capacities:
More informationDonald W. Reynolds Performance Hall Technical Information for Touring Companies
Donald W. Reynolds Performance Hall Technical Information for Touring Companies General Information Mailing Address UCA Public Appearances 201 Donaghey Avenue Stanley Russ Hall 225 Conway, AR 72035 Street
More informationRamsey Recital Hall Technical Information Packet 2017 General Information:
General Information: Location: Ramsey Recital Hall is located in the Performing Arts Center building at the Performing and Visual Arts Complex off River Road in Athens Ga. River Road can be accessed from
More informationTennessee Williams Theatre
Technical Specifications (Updated 02-15-2011) Stage Stage Floor Sprung pine covered with masonite Dance Floor..5 panels of marley flooring (5' x 45' Panels) Proscenium Opening...48-2 Proscenium Height...26-8
More information2016/2017 Technical Specifications. FOH Sound System. FOH Mains: 2- Meyer MSL-4 (1 Above, 1Below) + 1- Meyer DF-4P per side
2016/2017 Technical Specifications FOH Sound System FOH Mains: 2- Meyer MSL-4 (1 Above, 1Below) + 1- Meyer DF-4P per side 2- Meyer PSW-2 Dual 15 Subwoofers 2- Meyer UPM-1P Center Fills (Optional) 25- TOA
More informationAlways check availability of equipment Additional charges may apply PLEASE NOTE Stock availability may differ due to repairs etc
Technical Specifications SEATING CAPACITY Auditorium with no sound position: 366 Auditorium with sound position: 351 Auditorium with pit covered: 323 Sound position equates to 15 seats Four seats are reserved
More informationTHE CLAYTON CENTER TECHNICAL INFORMATION PACKET
THE CLAYTON CENTER TECHNICAL INFORMATION PACKET AS OF JANUARY 2016 THE CLAYTON CENTER TECHNICAL INFORMATION PACKET Thank you for considering the The Clayton Center for your performances. This technical
More informationN DI TECHNICAL RIDER PHOTO : SÉBA. imperialbell.com
PHOTO : SÉBA PHOT SÉBASTIE STIEN STIE N DI DION TECHNICAL RIDER A PROPERTY OF ADRESS 252, rue Saint-Joseph Est Québec (Québec) MANAGEMENT 240, rue Saint-Joseph Est Québec (Québec) G1K 3A9 General phone:
More informationThe Theater at Colorado Heights
The Theater at Colorado Heights Theater Manager - Dennis Leach O: 303-937-4009 C: 720-985-4886 DLeach@CHU.edu Technical Coordinator Cullen Munch O: 303-937-4012 C: 303-570-6241 CMunch@CHU.edu Director
More informationTHEATRE SPECIFICATIONS FOR WILLOW THEATRE
THEATRE SPECIFICATIONS FOR WILLOW THEATRE Booking Coordinator Stacee Lanz 561.347.3901 slanz@myboca.us Technical Theatre Supervisor Jason Hester 561.347.3914 jhester@myboca.us Facility Information Willow
More informationTechnical Specifications THEATRE
Table of Contents 1. General Information: 1.1. Seating Capacity 1.2. Equipment Set Up & Operation 1.3. Electrical Safety 1.4. Power Supply 2. Audio & Video: 3. Lighting: 2.1. Mixing Console 2.2. Playback
More informationTECHNICAL EQUIPMENT INFORMATION THE NORMAN ROTHSTEIN THEATRE Updated: November 2018
Stage Specifications: Stage Dimensions: Apron Dimensions: Proscenium Arch: Backstage Crossover: Wing space is limited Proscenium to upstage traveler 6.71 meters deep by 10.67 meters wide The apron down
More informationPlaza del Sol. Technical Specifications. Stage Rigging Schedule. California State University, Northridge. plaza del sol CONCERT HALL
Plaza del Sol Hall California State University, Northridge Technical Specifications Stage Rigging Schedule From Batten # Pl Name Length 0-0 Plaster Line Fc 0-3 Fire Curtain 43-0 1 1-0 House Curtain 56-0
More informationHOLLYWOOD CENTRAL PERFORMING ARTS CENTER
THEATER SPECIFICATIONS SEATING CAPACITY: 98 seats, as well as 8 spaces for wheel chairs, all on one biraked level. STAGE DIMENSIONS: DECK: Height from House floor = 3 5 Depth from Proscenium Arch to Cyclorama
More informationDobson High School Auditorium
Dobson High School Auditorium Dobson High School Auditorium 1501 W. Guadalupe Rd., Mesa, AZ 85202-7575 Crew (Staff, Student, Union, etc.): Staff (Non-IATSE) Layout Type of Theatre: Proscenium Orchestra
More informationCENTRO CULTURAL DE BELÉM FOUNDATION GRANDE AUDITÓRIO TECHNICAL FILE
CENTRO CULTURAL DE BELÉM FOUNDATION GRANDE AUDITÓRIO TECHNICAL FILE INDEX INDEX 1 INTRODUCTION 2 STAGE CONFIGURATION 3 ELECTRICAL POWER SUPPLY 3 FLYBAR SYSTEM 4 STAGE EQUIPMENT 4 ORCHESTRA PIT 4 ORCHESTRA
More informationCampbell Heritage Theatre. Technical Information.
www.heritagetheatre.org Stephen Milligan Production Manager Heritage Theatre 408.981.6785 heritage_production@yahoo.com Address: 1 W. Campbell Avenue Campbell, CA 95008 Box Office telephone: 408.866.2700
More informationAUDIO INVENTORY. Available as Front Fill Speakers Positioned evenly across the DS edge of stage 2 D&B V7P Speakers Available as Outer Fill Speakers
PAGE 50 OF 86 AUDIO INVENTORY SOUND SYSTEM INVENTORY QUANTITY MAKE AND MODEL USE 34 D&B V8 Speakers Mid-High L/R and Arrays 4 D&B V12 Speakers Mid-High L/R and Arrays 8 D&B V-Sub Speakers *both L/R and
More informationJeanne and Peter Lougheed Performing Arts Centre
Facility Information Jeanne and Peter Lougheed The Jeanne and Peter Lougheed is located at 4501 50 th Street in Camrose, Alberta. We are situated on the University of Alberta Augustana Campus, alongside
More informationSurrey Civic Theatres Main Stage at Surrey Arts Centre Technical Information
Surrey Civic Theatres Main Stage at Surrey Arts Centre Technical Information Current as of February 2019 Main Stage at Surrey Arts Centre is a 402 seat proscenium theatre All dimensions are in mm (imperial)
More informationDonald W. Reynolds Performance Hall Technical Information for Touring Companies
Donald W. Reynolds Performance Hall Technical Information for Touring Companies General Information Mailing Address UCA Public Appearances 201 Donaghey Avenue Stanley Russ Hall 225 Conway, AR 72035 Street
More informationTechnical Specifications Alhambra Stage
Technical Specifications Alhambra Stage TECHNICAL DEPARTMENT CONTACTS : - Technical Manager : Mr. Vincent Collin +41.22.418.36.10 / +41.79.203.99.82 - vincent.collin@ville-ge.ch - Lighting Technician :
More informationMAIN HOUSE TECHNICAL RIDER
FT version du 28/09/15 MAIN HOUSE TECHNICAL RIDER ENGLISH VERSION HOUSE page 2 / 10 587 seats on tier 4 public access at upper and lower row level Acousticaly treated ceiling CATWALKS AND TECHNICAL GALLERY
More informationJ. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO
J. W. ENNIS AUDITORIUM CENTENNIAL SECONDARY SCHOOL WELLAND, ONTARIO THEATRE TECHNICAL INFORMATION Revised Jan 11, 2014 Basic description of Performing Space: Proscenium Theatre Seating Capacity: 1,052
More informationTechnical Specifications Black Box
Table of Contents 1. General Information: 2. Audio & Video: 3. Lighting: 4. Staging: 1.1. Equipment Set Up & Operation 1.2. Electrical Safety 1.3. Power Supply 2.1. Mixing Console 2.2. Playback 2.3. Standard
More informationWaterside. Robert Bolt Theatre. Technical Rider
Waterside Robert Bolt Theatre Technical Rider 1 Waterside Plaza Sale Waterside Sale Cheshire M33 7ZF (Updated 24.11.2017) Robert Bolt Theatre- Summary Get In- Via Main Entrance No stairs. Smallest door
More informationLismore City Hall Churchill Auditorium Technical Specifications
Auditorium Technical Specifications 2014/2015 Please complete and return to venue@norpa.org.au / phone: 02 6622 0300 / fax: 02 6622 3175 Lismore City Hall is managed by Northern Rivers Performing Arts
More informationRobert Bolt Theatre. Technical Rider
Robert Bolt Theatre Technical Rider 1 Waterside Plaza Sale Waterside Sale Cheshire M33 7ZF (Updated 05.11.2014) Quick List Robert Bolt Theatre Get In- Via Main Entrance No stairs. Smallest door to reach
More informationDESCRIPTION OF FACILITIES
274 Main Street Northampton, Ma 01060 DESCRIPTION OF FACILITIES Office: (413) 584-9032 Email: info@aomtheatre.com http://www.aomtheatre.com Revised July 20, 2016 1 AUDITORIUM Hemp house built in 1891 Seating
More informationRiverCenter for the Performing Arts. House Sound System
RiverCenter for the Performing Arts House Sound System PLEASE NOTE THAT THE ENTIRE INVENTORY MAY NOT BE AVAILABLE FOR YOUR PRODUCTION. PLEASE CONFIRM INVENTORY WITH THE TECHNICAL DIRECTOR AT LEAST 30 DAYS
More informationCENTRO CULTURAL DE BELÉM FOUNDATION PEQUENO AUDITÓRIO TECHNICAL FILE
CENTRO CULTURAL DE BELÉM FOUNDATION PEQUENO AUDITÓRIO TECHNICAL FILE INDEX INDEX 1 INTRODUCTION 2 STAGE CONFIGURATION 2 ELECTRICAL POWER SUPPLY 2 FLYBAR SYSTEM 3 STAGE EQUIPMENT 3 ORCHESTRA FURNITURE 3
More informationNOTTINGHAM LAKESIDE ARTS DJANOGLY THEATRE TECHNICAL INFORMATION
If we do not receive your technical requirements and a lighting plan on Lakeside s plan at least four weeks before your visit, pre-rigging cannot be guaranteed. Please note that we will not pre-rig using
More informationTheatre Technical Specifications
Theatre Technical Specifications Seating Capacity: The Lakes Theatre STAGING INFORMATION Total 1200 seats Stage Dimensions: Width at widest Part 18m Rear stage width- 13m Stage depth (at centre) 7.4m Height
More informationTHE REPUBLIC CULTURAL CENTRE TECHNICAL FACILITIES (THEATRE)
THEATRE THEATRE SEATING CAPACITY: 1,111 (maximum) Stalls (Level 1) 744 wagon seats 62 orchestra pit seats 32 Balcony (Level 2) 273 Total: 1,111 22 seats in Stalls are removable for a maximum of 10 x wheelchair
More informationSee the lakeside website for up-to-date tech spec and drawings
Updated Sept 208 General Venue Information See the lakeside website for up-to-date tech spec and drawings https://www./technical.html 0m x 0m Maximum Performance Area Dimensions (See Ground Plan for Details)
More informationPalm Beach State College Eissey Campus Theatre Last revised: Jan General Technical Specifications Stage Dimensions:
Palm Beach State College Eissey Campus Theatre Last revised: Jan. 2015 General Technical Specifications Stage Dimensions: Proscenium Width: 44-0 Height of grid at stage floor: 70-0 Proscenium Height 22-0
More informationThe Crossing Venue Information & Specification 2013
THE CROSSING VENUE INFO & SPECIFICATION 1 The Crossing Venue Information & Specification 2013 Phone: 0121 694 5000 8am - 8pm Mon-Thurs 8am - 5pm Fri Outside UK please call +44 121 694 5000 Email: events@sccb.ac.uk
More informationGECC Theatre Technical Specifications
GECC Theatre Technical Specifications Senior Technician: Jayden Allen Mobile: 0417 097 992 Landline: 07 4972 2822 Email: JaydenA@gladstone.qld.gov.au Venue: Phone: 07 4972 2822 Website: www.gladecc.com.au
More informationA SPECIAL VENUE FOR SPECIAL EVENTS
A SPECIAL VENUE FOR SPECIAL EVENTS Technical Rider Théâtre Desjardins is managed by the Société de la salle Jean-Grimaldi. It s main partners are the Borough of LaSalle and André-Laurendeau Cegep. Equipped
More informationFleck Dance Theatre Technical Specifications As of September 2014
GENERAL INFORMATION: Stage Floor: The floor is double sprung with a maple hardwood surface. It is a light chestnut brown colour and is in good condition. IT MAY NOT BE SCREWED, NAILED OR STAPLED INTO!
More informationCONTACTS. Pantages Theatre 710 Hennepin Avenue Minneapolis, MN Steve Olson Operations Coordinator Phone: (612) Fax: (612)
Pantages Theatre 710 Hennepin Avenue Minneapolis, MN 55403 CONTACTS Steve Olson Operations Coordinator Phone: (612) 373-5654 Fax: (612) 746-3153 Gail Nelson Chief Operating Officer (612) 373-5673 Rick
More informationFOLKEN STORSALEN - FOH Production Specs - General Information
FOLKEN STORSALEN - FOH Production Specs - General Information Venue Promoter Visiting address Postal address Vat ID Folken Storsalen Studentersamfunnet Folken Løkkeveien 24 4008 Stavanger Norway Postboks
More informationNational Theater_stage
NT ET CH RH 01-1 1 National Theater : The Equipment 1-1 National Theater Facilities 1-1-1Main Elevators 1 Main Elevators The main stage of National Theater is 26.5M in width, 16.7M in depth; Superficial
More informationConcert Hall_sound Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage. Stage. Light. Sound. Video. Back Stage.
3- 3 : The Equipment 3 Control Room Item Brand/Type Amount Note Mixer STUDER VISTA- 8 40 Channel 0 Line Channel 8 Master mono 8 Group stereo 0 Aux mono 4 Aux Stereo CD player TASCAM CD-450 For performance
More informationLes Amazones d'afrique on tour 2017
STAGE DIMENSION AND BACKSTAGE AREA The Promoter will provide a stage with the following dimensions: Width: 10 m. / Depth: 8 m. / Height: depending on the venue. The P.A. wings should be on the same level
More informationBuffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222
(Revised December 2015) Buffalo State Performing Arts Center SUNY Buffalo State 1300 Elmwood Ave. ROCK 210 Buffalo, New York 14222 PAC STAFF Director of Operations Jeff Marsha 716-878-3599 marshajl@buffalostate.edu
More informationTechnical Specifications Alhambra Stage
Technical Specifications Alhambra Stage TECHNICAL DEPARTMENT CONTACTS: Technical Manager: Mr.Vincent Collin +41.22.418.36.10/+41.79.203.99.82 Lighting Technician: Mr.Frédéric Fellmann +41.22.418.36.09/+41.79.476.69.10
More informationGusman Concert Hall Technical Rider
Gusman Concert Hall Technical Rider Location: 1314 Miller Drive, Coral Gables, Florida 33146 Load In and Out: Stage right, through elevator, or using a handicap ramp from the front of the building to stage
More informationHorizon Foundation for New Jersey Theater. Newark, New Jersey
Horizon Foundation for New Jersey Theater Newark, New Jersey THEATER TECHNICAL SPECIFICATIONS Page 1 of 7 TABLE OF CONTENTS GENERAL INFORMATION 3 Contact Sheet 4 Directions 5 Parking Loading Access STAGING
More informationNEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY
NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY VICTORIA THEATER TECHNICAL SPECIFICATIONS Correct as of 11.08.07 Page 1 of 10 CONTACT SHEET NEW JERSEY PERFORMING ARTS CENTER One Center Street, Newark,
More informationMANDURAH PERFORMING ARTS CENTRE BOARDWALK THEATRE. Stage & Auditorium Specifications
MANDURAH PERFORMING ARTS CENTRE BOARDWALK THEATRE Email: tech@manpac.com.au Phone: 08 9550 3911 TECHNICAL STAFF CONTACT Alexander Dick Peter Lovell Clinton Gerard Technical Supervisor Audio Technician
More informationMonchichi. Company Wang Ramirez A duo by Sébastien Ramirez & Honji Wang. TECHNICAL RIDER North America
Compagnie Wang Ramirez www.wangramirez.com Clash c/o Casa Musicale 1 rue Jean Vielledent 000 Perpignan France SIRET : 0 854 30 000 APE : 9001Z N TVA intracommunautaire/eu VAT N : FR35 0 854 30 Licences
More informationThe Bridgewater Hall Technical Specifications
The Bridgewater Hall Technical Specifications General Information Capacity (Maximum) Fixed seating auditorium: 2341 on four levels, including 16 wheelchair spaces Artist s Rooms/Orchestra Rooms/Production
More informationSt Pancras Room Technical Specification
St Pancras Room Technical Specification Details shown are correct as of January 2012 Subject to change. Kings Place Music Foundation 90 York Way, London N1 9AG www.kingsplace.co.uk St Pancras Room 2.1
More informationTechnical Specifications
Updated 2016-11-03 360 University Drive NE New Philadelphia, Ohio 44663 Box Office Phone: 330-308-6400 Fax: 330-308-6464 http://www.kent.edu/tusc/pac House Stage Box Office Manager General Manager Production
More informationFront-Of-House mixing desks: Monitor mixing desk: House speakers (main stacks): Allen & Heath GL4000. Allen & Heath GL4
COMFAC Concert Sound Equiipment Liist Front-Of-House mixing desks: Allen & Heath GL4000-40 channel (40x8xx1), 4-band full sweep equalizers with selectable Q mids - sweepable lo-cut filters / phase reverse
More informationDROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre
DROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre Technical Rider V2 - Trio Version TEAM & SCHEDULE The following technical rider presents the Trio version of Drops & Points. It is a modular live
More informationTechnical Rider. Latest revision March 2017 ABBA-Salutely 70 s Show Director: Sammy Pawlak,
Latest revision March 2017 ABBA-Salutely 70 s Show Director: Sammy Pawlak, sammypawlak@yahoo.com 407-492-8028 Technical Rider The following Technical Rider is provided by ABBA-Salutely 70 s to ensure the
More informationHuntsville Algonquin Theatre AUDIO INVENTORY
Huntsville Algonquin Theatre AUDIO INVENTORY FOH Audio Console 1 Yamaha CL5 Note: Audio booth located aprox 50' from stage under short balcony, slightly stage right of centre. Booth area is 6'd x 8'w.
More informationGreen Room: Fridge, microwaves and tea and coffee making facilities (tea and coffee available subject to small donation)
Salberg - Technical Information Visiting Company Specification Updated February 2018 STAGE Stage Information: Width: 8300 Max Upstage, 5000 Max between seating blocks Depth: 7000 Max, 3500 Max between
More informationHult Center for the Performing Arts Technical Specifications
Hult Center for the Performing Arts Technical Specifications Silva Concert Hall Technical Director, Brian Ference Asst Technical Director, Mike Carpenter.... Brian.R.Ference@ci.eugene.or.us Michael.C.Carpenter@ci.eugene.or.us
More informationSCOTT RECORD PERFORMANCE RIDER FOR 8 PIECE ORCHESTRA
SCOTT RECORD PERFORMANCE RIDER FOR 8 PIECE ORCHESTRA ALL MINIMAL REQUIREMENTS LISTED ARE GENERAL AND ALL BRAND NAMES AND MODELS ARE INTERCHANGEABLE WITH PRODUCTS OF EQUAL QUALITY AND PERFORMANCE. I. SOUND
More informationRIDER TECNICO OCT 2012 ( )
RIDER TECNICO OCT 2012 (07-10-2012) PLEASE DISCARD ANY PREVIOUS TECHNICAL REQUIREMENTS YOU MAY HAVE While all riders seem equal, it is extremely important that all information contained in this document
More informationWe Are Monchichi. Wang Ramirez Company TECHNICAL RIDER
Compagnie Wang Ramirez www.wangramirez.com Clash66 c/o Casa Musicale 1 rue Jean Vielledent 66000 Perpignan France SIRET : 500 54 0 000 APE : 9001Z N TVA intracommunautaire/eu VAT N : FR5 500 54 0 Licences
More informationCAT4 Meyer MPS-488HP. FOH -> Amp Room House Patchbay. Amp Room QSC Powerlight A. Amp Room QSC Powerlight B
Assistant Laptop HEADPHONES /" TRS - Dual /" TS Mixer Line In Line In Apple Wired Keyboard Apple Wired Mouse Mac Mini ' A-B UB MADI BNC IN BNC OUT UB-MADI 0' UB-MADI 0' DIGICO SD9 UB MADI OUT Local UB
More informationGotoGuta. Technical Rider V1 for GotoGuta by FRIKAR Page 1 of 6
GotoGuta by Technical Rider V1 / edited 7.7.2015 HM The Piece Is performed by 3 dancers, Hallgrim Hansegård, Ådne Kolbjørnshus, Vetle Springgard and the musician Andris Hemsing " GotoGuta, is a Valdresdialect
More informationCAPACITY 650 Kapelstraat 13, 5401 EC Uden PHONE 0031 (0) FAX 0031 (0) IMPORTANT NOTES PROHIBITED SMOKING
VENUE DE PUL HALL MAIN HALL CAPACITY 650 ADDRESS Kapelstraat 13, 5401 EC Uden PHONE 0031 (0)413-265091 FAX 0031 (0)413-266125 WEB www.livepul.com PROHIBITED SMOKING GET-IN SETTLEMENT LOCAL CREW SECURITY
More informationDROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre
DROPS & POINTS by Pascal Schumacher feat. Maxime Delpierre Technical Rider - Extended Version V2 TEAM & SCHEDULE The following technical rider presents the extended version of Drops & Points. It is a modular
More informationLast Updated January 2018
Last Updated January 2018 I CONTACTS Staff Technical Manager: Chris Gaughan Telephone: +353 21 490 5209 Mobile: +353 86 601 8517 Email: cgaughan@corkoperahouse.ie Stage Manager: Declan O Mullane Telephone:
More informationTechnical specifications Short Format Subject to alteration-please call us to confirm details.
1. Belmont Street, Bognor Regis West Sussex. PO21 1BL tech@regiscentre.co.uk iain.jordan@regiscentre.co.uk Tel / Fax: 01243 867676 Box Office: 01243 861010 Technical specifications Short Format Subject
More informationVISHAL AND SHEKHAR. AUDIO AnD VIDEO TECHnICAL RIDER 2012.A
VISHAL AND SHEKHAR AUDIO AnD VIDEO TECHnICAL RIDER 2012.A Please go through each Page of this rider thoroughly so that all equipment is correctly provided for the event. All exceptions /substitutions must
More informationTechnical Specifications Alhambra Stage
Technical Specifications Alhambra Stage Technical Department Contacts: -Technical Manager: Mr.Vincent Collin +41.22.418.36.10/+41.79.203.99.82 vincent.collin@ville-ge.ch -Lighting Technician: Mr.Frédéric
More informationMulti-Purpose Auditorium. Sound Reinforcement System Design. ECE Spring 2018 Team 3
Multi-Purpose Auditorium Sound Reinforcement System Design ECE 40020 Spring 2018 Team 3 Trey Overholser, Luke Molloy, Tom Kearns, Michael Furnish Slide # 1 of 22 Outline Primary System Design Constraints
More informationOGRE Portugal Technical Rider
OGRE Portugal Technical Rider Technical rider Sound 1.FOH 1.1- Speaker system Must be in stereo and of adequate size to cover the venue. Speaker system will include all needed amplifiers and controllers
More informationTechnical Information Package I. Personnel
A Center for the performing arts serving Richmond and Scotland Counties. 1042 West Hamlet Avenue, Post Office Box 1189 Hamlet, North Carolina 28345 Technical Information Package I. Personnel Director Direct
More informationPrice List for Lease of Facilities and Equipment of the Concert Hall Great Amber
Price List for Lease of Facilities and Equipment of the Concert Hall Great Amber Great Hall Specification total area 1170 m 2 ceiling height 23.70 m Inclined floor with a possibility to level the stalls
More informationNEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY
NEW JERSEY PERFORMING ARTS CENTER NEWARK, NEW JERSEY PRUDENTIAL HALL TECHNICAL SPECIFICATIONS Contact Production Dept for updates correct as of 04-29-10 Page 1 of 12 CONTACT SHEET NEW JERSEY PERFORMING
More informationTECH RIDER 7 DAYS IN ALASKA
1 av 5 TECH RIDER 7 DAYS IN ALASKA Contacts Kickstart Booking: Band og technician: Jørgen Bertelsen Ole Gunnersen jorgen@ksbooking.no ole@gunnersen.no tlf: +47 980 34 060 tlf: +47 950 93 843 This rider
More informationThe Kala Chethena Kathakali Company TECHNICAL INFORMATION Large theater venue
The Kala Chethena Kathakali Company TECHNICAL INFORMATION Large theater venue GET OUT TIME: 1 hour approximately after the end of show. [ ] SOUND CHECK: - to be agreed AT LEAST 1 HOUR BEFORE THE START
More informationTECHNICAL SPECIFICATIONS LABAN THEATRE
TECHNICAL SPECIFICATIONS LABAN THEATRE The Bonnie Bird theatre is intended to provide a first class environment for an audience of 296 to watch contemporary dance performed by both student and visiting
More informationUnder The Radar Technical Rider
Under The Radar Technical Rider Scope This Technical Rider shall define the requirements for the Under The Radar (The Artists) Front of House (FOH), Monitor Mix sound system, stage dimensions, stage AC
More informationMulti-Purpose Auditorium Sound Reinforcement System Design ECE Spring 2018 Group 4
Multi-Purpose Auditorium Sound Reinforcement System Design ECE 40020 Spring 2018 Group 4 From Left to Right: Derek Tenny, Devin Clausen, Zack Bennett Outline Primary System Design Constraints Venue Illustration
More informationAPACA Technical Specifications Guidelines
APACA Technical Specifications Guidelines These guidelines have been developed through extensive consultation with the industry and whilst differences in venues and productions are extensive the standards
More informationCLIENT TO SUPPLY: OTHER BANDS: please make you own copy rather than copy/paste ours!
WB PRODUCTIONS WildBoys Technical Rider for Theatre shows, Jan 2018 Telephone Steve on +44 (0)7776 127 468 with any queries. If any of the items listed are not available and substitutions need to be made
More informationStage size: Height: 0,8m Depth: 5m Width: 6,75m Clearance: 2,3m - 4m (slanted roof) + additional working space behind the backdrop (Black Molton)
1 / 5 KERUBIN SALI VENUE INFO & TECHNICAL DETAILS Updated 23rd Mar 2018 GENERAL INFORMATION Venue address: Siltakatu 1 (Ilosaari) 80100 JOENSUU, Finland https://goo.gl/maps/0fl4w Capacity: 450 standing
More informationPINK TURTLE THEATRE RIDER
PINK TURTLE THEATRE RIDER This rider is part of the contract: please read it carefully, don t hesitate to call us to get more information. Remember we can always find solutions providing we have reasonable
More information