Nature Methods: doi: /nmeth Supplementary Figure 1. Resolution of lysozyme microcrystals collected by continuous rotation.
|
|
- Jesse Peters
- 5 years ago
- Views:
Transcription
1 Supplementary Figure 1 Resolution of lysozyme microcrystals collected by continuous rotation. Lysozyme microcrystals were visualized by cryo-em prior to data collection and a representative crystal is shown (inset, scale bar represents 1 μm). Well diffracting crystals were typically on the order of 2 µm x 2µm x 0.5 µm in size. The crystal shown is a wedge that measured as 0.5 μm thick at the center and 0.15 μm thick at the edges. A representative diffraction pattern from a lysozyme microcrystal collected under continuous rotation. This individual frame was collected over 4 s at a dose of ~0.01 e-/å2/s and a rotation -1 rate of 0.09 s. The diffraction pattern shows visible reflections extending to ~ 2 Å resolution and beyond. The contrast of this image was enhanced in Fiji25 to enable spot visualization for this figure.
2 Supplementary Figure 2 Radiation damage assessment of continuously exposed microcrystals. (a) A single crystal was exposed continuously for 120 frames for a final accumulated dose of 12.0 e - /A 2 (0.1 e - /A 2 per frame). A representative region from diffraction patterns originating from the same crystal in the same orientation is shown as a function of accumulated dose. It can be seen qualitatively that the intensities of the reflections decrease as dose is accumulated, especially at higher resolutions (see arrows in top left panel), and this effect becomes more severe for all reflections at the higher dosages (8.0 e - /A 2 and 12.0 e - /A 2 ). (b) In order to more quantitatively investigate the negative effects of radiation damage, intensities in the resolution bins of 2-3 Å (2 randomly chosen reflections) as well as 3-6 Å (7 randomly chosen reflections) were selected and their normalized intensity as a function of accumulated dose was analyzed. It was found that the higher resolution reflections suffer relatively early (~2 e - /Å 2 of total accumulated dose, blue), whereas the intensities between 3 Å and 6 Å do not decrease drastically until approximately 5 to 6 e - /Å 2 of total accumulated dose (black). Error bars represent standard error of the mean.
3 Supplementary Figure 3 Process flow from raw data to completely processed data set using MOSFLM. The raw data collected on the TEM is first converted to a file compatible with MOSFLM by an in-house script. MOSFLM then uses automated spot finding to determine the position of the reflections on the images. Following spot finding MOSFLM uses the relative positions of each reflection to determine crystal lattice parameters and the crystals orientation. This then allows the location of each reflection within the data set to be predicted, properly indexed, and integrated. After merging and scaling, process of converting the many raw diffraction patterns into one reflection file is complete.
4 Supplementary Figure 4 Continuous rotation reduces dynamical scattering. (a-b) Diffraction patterns near the (001) major planes of lysozyme were used to assess the level of dynamic scattering by looking at the systematic absences along the a* axis for both still diffraction data (a) and continuously rotated diffraction data (b). The data from (a) and (b) come from two different crystals. (c-d) The intensity of reflections along a* was quantified and plotted for the still diffraction and continuously rotated diffraction patterns (the portion of the diffraction patterns indicated by the box inset). The plot from still diffraction (c) clearly show small but significant levels of intensity coming from dynamic scattering for reflections (2n+1,0,0), which are forbidden in P symmetry. The intensities of these forbidden reflections are greatly reduced when continuous rotation is used (d).
5 SUPPLEMENTARY INFORMATION Supplementary Results Radiation damage assessment Previously, we assessed the radiation damage for the collection of still data sets, where the crystal undergoes pulses of exposure followed by a rest period as the crystal is tilted 4. When collecting still data sets, the dose where reflection intensities from a single lysozyme microcrystal began to deteriorate was ~ 9 e - /Å 2. This allowed us to collect up to 90 frames at the set dose rate of 0.01 e - /Å 2 /s with a 10 s exposure per frame. In the continuous rotation method, the crystal is continuously exposed to the electron beam without rest periods, therefore, it was important to characterize the radiation damage to determine how long the crystal could be exposed before radiation damage became too severe and the crystal was destroyed. Again, we used lysozyme as a model microcrystal and examined the decrease in reflection intensities as the electron beam constantly bombarded the sample during a continuous exposure (Supplementary Video 1). The microcrystal was oscillated between - 1 and 1 to collect full intensities and to account for beam- induced crystal rocking that could affect the recorded intensities. The microcrystal was subjected to 120 exposures, each at a total dose of 0.1 e - /Å 2 without pausing between exposures, and the intensities as a function of dose were measured for randomly chosen reflections in the ranges of 2-3 Å and 3-6 Å (Supplemental Fig. 2). We found that the crystal experiences significant radiation damage, especially beyond a total dose of ~6 e - /Å 2 where the measured intensities dropped below ~50% of their original value. The higher resolution reflections deteriorate at a higher rate than those at lower resolution. Reflections in the 2-3Å resolution range vanished very quickly, within a total dose of only ~2e - /Å 2 leading to a 50% reduction in measured intensity. These results are significantly different than for the still data set 4. It is possible that with pulses followed by rest periods of up to 10 s, the free radicals 21 and hydrogen gas 22 generated during the exposure have time to diffuse from the 1
6 microcrystal during the rest period, before they can accumulate to high concentrations and cause substantial damage. However, with a continuous exposure the accumulation of free radicals or hydrogen gas could exceed the diffusion rate, leading to higher concentration of damaging species and increased levels of damage. It is also possible that increased sample heating 23 caused by the incident beam during the continuous exposure is a significant factor contributing to the observed rapid decay of the crystal lattice during the continuous exposure. This suggests that lowering the intensity of the electron beam and recording the diffraction data over longer times may decrease the effects of beam- induced damage, however this is currently not possible with the current experimental set up. Future analysis and optimization should help clarify the effects of radiation damage during continuous rotation. While these data indicate there is more radiation damage for continually exposed crystals, our hypothesis was that the improvement in overall data quality by continuous rotation justifies the higher levels of radiation damage. We therefore set the limit for continuously rotated data sets to < 5 e - /Å 2 where the damaging effects of the electron beam appear tolerable. Using MOSFLM with continuous rotation data The images from the TVIPS CMOS detector were converted to the Super Marty View (SMV) image format, which is a format recognized by MOSFLM. Based on the distribution of pixel values in these images, the ADC offset parameter was set to zero. The MOSFLM gain parameter was set to 2.0, a value derived by observing the variation in background regions around diffraction spots and adjusting the gain so that this matched the variation expected from Poisson statistics. The background levels in the images at high resolution were very low and pixels with a value of zero were not uncommon. To avoid rejecting reflections that included pixels with a value of zero, the Null pixel threshold parameter was set to - 1 (the default value is zero). Correct indexing was not possible for a single MicroED pattern, while this is possible for most X- ray diffraction images. This because the Ewald sphere in our experiments has a very limited curvature for the wavelength used (0.025 Å), 2
7 resulting in very limited information about the reciprocal space parameters along the beam direction. In practice it was found that several images spaced over a tilt range of at least 20 were required, and the most robust indexing results were obtained using 6 images equally spaced in phi, covering a total rotation range of 35. The cell parameters from indexing were used for integration, without any further refinement. When integrating the images, the detector tilt and twist parameters (describing rotations of the detector plane about axes parallel and normal to the rotation axis respectively) were not well defined and were fixed at zero. This is due to the relatively small size of the detector (64 x 64 mm) and the lack of strong reflections at higher resolution. The crystal mosaicity required particular attention. Because of the way in which the CMOS detector is read out while the crystal is continuously rotating, the effective rotation range of an image is continually shifted across the image (see explanation below). At present there is no way of allowing for this in the MOSFLM software (although the necessary changes are now being introduced). To avoid missing reflections that are present on an image, but would not be predicted to be present based on the nominal start and end phi values for that image, the crystal mosaicity was set to an artificially high value of 2 and the mosaic block size was set to 5 microns. This resulted in significant over- prediction (as judged by the width of individual reflection lunes) but successfully predicted all the spots present on the image. Smaller values for the mosaic spread resulted in a significant deterioration in data quality as judged by the merging R- factor. The effect of the high mosaicity will be to include more background along with the true Bragg intensity when integrating any particular reflection, because a reflection will be predicted to be present on more images than it actually is. This will result in a loss in data quality that will be most apparent for the weak, high- resolution reflections. The mosaic block size parameter is almost certainly an imperfect way of modelling what is actually happening in the crystal, but it is certainly much better than making no correction at all. That is why the absolute value of the mosaic block size that gives the best prediction cannot be directly translated into the physical mosaic block size of the crystal. The value is adjusted heuristically to get the best prediction of what is observed in the diffraction pattern. 3
8 Therefore, the mosaic block model is not a perfect model of the physical reality and the absolute value cannot be taken too literally, but the advantage of using this model in terms of the quality of the resulting data (especially Rmerge at low resolution) is very clear (Supplemental Table 1). The increased mosaicity is necessary because of the rolling shutter mode of the detector readout. In this mode, each line of pixels in the image (4096 x 4096 pixels) is read out sequentially, line by line, with a readout time of ~100 µs during which time that line of pixels is inactive (but the remainder of the detector is still active). Immediately following readout, the line of pixels becomes active again. It takes ~400 ms to read out the entire detector, and during this time, the crystal is rotating continuously. As a result, the rotation angle corresponding to the beginning of the exposure varies across the detector. The rotation angle corresponding to the end of the exposure for each line (i.e. immediately before that line is read out) varies in the same way. Thus, for all lines making up the image, the total rotation angle per exposure is the same (0.36 in these experiments), but the starting (and ending) rotation angle differs across the image. This is quite different to the readout for typical CCD or image plate detectors used in X- ray diffraction, where the shutter is closed and the crystal rotation is stopped while the entire image is read out. Correctly allowing for the mode of the detector readout and further optimization of data collection parameters and equipment (e.g. per frame rotation range and faster read- out times from the detector) should therefore extend the resolution of the analyzed diffraction data beyond that reported here and should allow us to reach the recorded resolution limit of ~1.9Å of our data. 4
9 Supplementary Table 1. Data collection and refinement statistics Data Collection Excitation voltage Electron Source 200kV Wavelength (Å) Total dose per crystal (e - /Å 2 ) ~4.5 Frame rate (s/frame) 4 Rotation rate ( /s) 0.09 Total Angular range per crystal ( ) ~44 Field Emission Gun Merging Statistics 2 total crystals Single crystal Space group P P Unit cell dimensions a, b, c (Å) 76.0 Å, 76.0 Å, 37.2 Å 75.9 Å, 75.9 Å, 36.9 Å α=β=γ Resolution Å Å Total reflections R merge (%) c 13.9 (29.9) a 15.5 (29.2) a Total Unique Reflections Multiplicity 4.8 (4.9) a 3.4 (3.2) a Completeness (%) 97.2 (90.2) a 80.1 (80.1) a Mean (I/σ(I)) 11.8 (6.0) a 8.7 (4.7) a Data Refinement Reflections in working set Reflections in test set R work/r free (%) 22.0/ /25.3 RMSD Bonds Å Å RMSD Angles Ramachandran (%) b (Favored, allowed, outlier) 97.9; 2.1; ; 4.0; 0 a Values for highest resolution shell of 2.6 Å 2.5 Å b Statistics given by MolProbity 24 c!!!!,!!!! R!"#$" = ; where I i,j is the integrated intensity for the j th observation of the unique!!!!,! reflection i and I i is the weighted mean intensity for reflection i. 5
10 SUPPLEMENTARY REFERENCES 21. Henderson, R. P Roy Soc B- Biol Sci 241, 6-8 (1990). 22. Meents, A., Gutmann, S., Wagner, A. & Schulze- Briese, C. Proceedings of the National Academy of Sciences of the United States of America 107, (2010). 23. Larsen, F.K. Acta Crystallogr B 51, (1995). 24. Chen, V.B. et al. Acta crystallogr D 66, (2010). 25. Schindelin, J. et al. Nat Methods 9, (2012). 6
Nature Protocols: doi: /nprot
Supplementary Tutorial A total of nine examples illustrating different aspects of data processing referred to in the text are given here. Images for these examples can be downloaded from www.mrc- lmb.cam.ac.uk/harry/imosflm/examples.
More informationSupplementary Figure 1
Supplementary Figure 1 Technical overview drawing of the Roadrunner goniometer. The goniometer consists of three main components: an inline sample-viewing microscope, a high-precision scanning unit for
More informationR-AXIS RAPID. X-ray Single Crystal Structure Analysis System. Product Information
The Rigaku Journal Vol. 15/ number 2/ 1998 Product Information X-ray Single Crystal Structure Analysis System R-AXIS RAPID 1. Introduction X-ray single crystal structure analysis is known as the easiest
More informationSupplementary Information
Supplementary Information Supplementary Figure 1. Modal simulation and frequency response of a high- frequency (75- khz) MEMS. a, Modal frequency of the device was simulated using Coventorware and shows
More informationPixel Array Detectors: Counting and Integrating
Pixel Array Detectors: Counting and Integrating Roger Durst, Bruker AXS October 13, 2016 1 The quest for a perfect detector There is, of course, no perfect detector All available detector technologies
More informationBackground Correction to Experimental CCD Images of X-ray Diffraction, Showing a Temporal Oscillation of Pendellösung Interference Fringes
BL-15C /2011G032 Background Correction to Experimental CCD Images of X-ray Diffraction, Showing a Temporal Oscillation of Pendellösung Interference Fringes Jun-ichi Yoshimura and Keiichi Hirano Photon
More informationSupplementary Figure S1 X-ray diffraction pattern of the Ag nanowires shown in Fig. 1a dispersed in their original solution. The wavelength of the
Supplementary Figure S1 X-ray diffraction pattern of the Ag nanowires shown in Fig. 1a dispersed in their original solution. The wavelength of the x-ray beam was 0.1771 Å. The saturated broad peak and
More informationNo part of this material may be reproduced without explicit written permission.
This material is provided for educational use only. The information in these slides including all data, images and related materials are the property of : Robert M. Glaeser Department of Molecular & Cell
More informationDATA COLLECTION WITH R-AXIS II, AN X-RAY DETECTING SYSTEM USING IMAGING PLATE
THE RIGAKU JOURNAL VOL. 7 / NO. 2 / 1990 Technical Note DIFFRACTION DATA COLLECTION WITH R-AXIS II, AN X-RAY DETECTING SYSTEM USING IMAGING PLATE ATSUSHI SHIBATA R&D Division, Rigaku Corporation 1. Introduction
More informationGeneral principles of image processing in cryo-em
Lecture 13 E. Orlova Birkbeck College, London General principles of image processing in cryo-em Cryo EM & 3D Image Processing 8 July 2016 Thiruvananthapuram, India William Lawrence Bragg Crystallography
More informationFEI Falcon Direct Electron Detector. Best Practice Document
FEI Falcon Direct Electron Detector Best Practice Document 2 1. Introduction FEI Falcon Direct Electron Detector Best Practice Application Guide The FEI Falcon Detector is based on direct electron detection
More informationProcessing data collected with Pilatus/Eiger detectors. James Parkhurst IUCR Computing School, Bangalore, August 2017
Processing data collected with Pilatus/Eiger detectors James Parkhurst IUCR Computing School, Bangalore, August 2017 Introduction Overview of Pilatus/Eiger detectors Overview of the DIALS integration program
More informationNanoSpective, Inc Progress Drive Suite 137 Orlando, Florida
TEM Techniques Summary The TEM is an analytical instrument in which a thin membrane (typically < 100nm) is placed in the path of an energetic and highly coherent beam of electrons. Typical operating voltages
More informationBias errors in PIV: the pixel locking effect revisited.
Bias errors in PIV: the pixel locking effect revisited. E.F.J. Overmars 1, N.G.W. Warncke, C. Poelma and J. Westerweel 1: Laboratory for Aero & Hydrodynamics, University of Technology, Delft, The Netherlands,
More informationCamera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note
Technical Note CMOS, EMCCD AND CCD CAMERAS FOR LIFE SCIENCES Camera Test Protocol Introduction The detector is one of the most important components of any microscope system. Accurate detector readings
More informationCCP4 Workshop Chicago 2011 Data Integration with XDS
CCP4 Workshop Chicago 2011 Data Integration with XDS Dept. of Structural Chemistry, University of Göttingen June 2011 http://shelx.uni-ac.gwdg.de tg@shelx.uni-ac.gwdg.de CCP4 Chicago 2011: XDS 1/29 The
More informationProperties of a Detector
Properties of a Detector Quantum Efficiency fraction of photons detected wavelength and spatially dependent Dynamic Range difference between lowest and highest measurable flux Linearity detection rate
More informationProcedures for Performing Cryoelectron Microscopy on the FEI Sphera Microscope
Procedures for Performing Cryoelectron Microscopy on the FEI Sphera Microscope The procedures given below were written specifically for the FEI Tecnai G 2 Sphera microscope. Modifications will need to
More informationOCT Spectrometer Design Understanding roll-off to achieve the clearest images
OCT Spectrometer Design Understanding roll-off to achieve the clearest images Building a high-performance spectrometer for OCT imaging requires a deep understanding of the finer points of both OCT theory
More informationDiamond X-ray Rocking Curve and Topograph Measurements at CHESS
Diamond X-ray Rocking Curve and Topograph Measurements at CHESS G. Yang 1, R.T. Jones 2, F. Klein 3 1 Department of Physics and Astronomy, University of Glasgow, Glasgow, UK G12 8QQ. 2 University of Connecticut
More informationCommissioning Results of The Protein Microcrystallography Beamline TPS 05A
Science Advisory Committee Meeting Commissioning Results of The Protein Microcrystallography Beamline TPS 05A Construction Team Leader: Yuch-Cheng Jean 2016.09.21 0 Outline I. Beamline Introduction II.
More informationSchematic diagram of the DAP
Outline Introduction Transmission mode measurement results Previous emission measurement Trapping mechanics Emission measurement with new circuits Emission images Future plan and conclusion Schematic diagram
More informationThe predicted performance of the ACS coronagraph
Instrument Science Report ACS 2000-04 The predicted performance of the ACS coronagraph John Krist March 30, 2000 ABSTRACT The Aberrated Beam Coronagraph (ABC) on the Advanced Camera for Surveys (ACS) has
More informationTEM theory Basic optics, image formation and key elements
Workshop series of Chinese 3DEM community Get acquainted with Cryo-Electron Microscopy: First Chinese Workshop for Structural Biologists TEM theory Basic optics, image formation and key elements Jianlin
More informationExperiment #12 X-Ray Diffraction Laboratory
Physics 360/460 Experiment #12 X-Ray Diffraction Laboratory Introduction: To determine crystal lattice spacings, as well as identify unknown substances, a x-ray diffractometer is used to replace the traditional
More informationPERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY
12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY Rajashekar
More informationECEN 4606, UNDERGRADUATE OPTICS LAB
ECEN 4606, UNDERGRADUATE OPTICS LAB Lab 2: Imaging 1 the Telescope Original Version: Prof. McLeod SUMMARY: In this lab you will become familiar with the use of one or more lenses to create images of distant
More informationUnderstanding Optical Specifications
Understanding Optical Specifications Optics can be found virtually everywhere, from fiber optic couplings to machine vision imaging devices to cutting-edge biometric iris identification systems. Despite
More informationRadiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893
Digital Radiography D. J. Hall, Ph.D. x20893 djhall@ucsd.edu Background Common Digital Modalities Digital Chest Radiograph - 4096 x 4096 x 12 bit CT - 512 x 512 x 12 bit SPECT - 128 x 128 x 8 bit MRI -
More informationFIBER OPTICS. Prof. R.K. Shevgaonkar. Department of Electrical Engineering. Indian Institute of Technology, Bombay. Lecture: 37
FIBER OPTICS Prof. R.K. Shevgaonkar Department of Electrical Engineering Indian Institute of Technology, Bombay Lecture: 37 Introduction to Raman Amplifiers Fiber Optics, Prof. R.K. Shevgaonkar, Dept.
More informationSupplementary Figure S1. Schematic representation of different functionalities that could be
Supplementary Figure S1. Schematic representation of different functionalities that could be obtained using the fiber-bundle approach This schematic representation shows some example of the possible functions
More informationQuantitative HRTEM investigation of an obtuse angle dislocation reaction in gold with a C S corrected field emission microscope
Quantitative HRTEM investigation of an obtuse angle dislocation reaction in gold with a C S corrected field emission microscope Joerg R. Jinschek 1, Ch. Kisielowski 1,2, T. Radetic 1, U. Dahmen 1, M. Lentzen
More informationAn Introduction to CCDs. The basic principles of CCD Imaging is explained.
An Introduction to CCDs. The basic principles of CCD Imaging is explained. Morning Brain Teaser What is a CCD? Charge Coupled Devices (CCDs), invented in the 1970s as memory devices. They improved the
More informationX-RAY COMPUTED TOMOGRAPHY
X-RAY COMPUTED TOMOGRAPHY Bc. Jan Kratochvíla Czech Technical University in Prague Faculty of Nuclear Sciences and Physical Engineering Abstract Computed tomography is a powerful tool for imaging the inner
More informationMultianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors
Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors F. Muheim a edin]department of Physics and Astronomy, University of Edinburgh Mayfield Road, Edinburgh EH9 3JZ,
More informationFig.2: Scanner VistaScan for image plates
RADIOGRAPHIC INSPECTION OF WELDINGS BY DIGITAL SENSORS H. Thiele, H.-J. Friemel RADIS GmbH, Johanniskirchen, Germany Abstract: The newly available digital sensors for radiographic inspection are suitable
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. JY/T
Translated English of Chinese Standard: JY/T011-1996 www.chinesestandard.net Sales@ChineseStandard.net INDUSTRY STANDARD OF THE JY PEOPLE S REPUBLIC OF CHINA General rules for transmission electron microscopy
More informationPhase plates for cryo-em
Max Planck Institute of Biochemistry Martinsried, Germany MAX PLANCK SOCIETY Phase plates for cryo-em Rado Danev Max Planck Institute of Biochemistry, Martinsried, Germany. EMBO course 2017, London, UK
More informationSupplementary Figures
Supplementary Figures Supplementary Figure 1 EM wave transport through a 150 bend. (a) Bend of our PEC-PMC waveguide. (b) Bend of the conventional PEC waveguide. Waves are incident from the lower left
More informationHigh Resolution BSI Scientific CMOS
CMOS, EMCCD AND CCD CAMERAS FOR LIFE SCIENCES High Resolution BSI Scientific CMOS Prime BSI delivers the perfect balance between high resolution imaging and sensitivity with an optimized pixel design and
More informationExposure schedule for multiplexing holograms in photopolymer films
Exposure schedule for multiplexing holograms in photopolymer films Allen Pu, MEMBER SPIE Kevin Curtis,* MEMBER SPIE Demetri Psaltis, MEMBER SPIE California Institute of Technology 136-93 Caltech Pasadena,
More informationVery short introduction to light microscopy and digital imaging
Very short introduction to light microscopy and digital imaging Hernan G. Garcia August 1, 2005 1 Light Microscopy Basics In this section we will briefly describe the basic principles of operation and
More informationTechnical Explanation for Displacement Sensors and Measurement Sensors
Technical Explanation for Sensors and Measurement Sensors CSM_e_LineWidth_TG_E_2_1 Introduction What Is a Sensor? A Sensor is a device that measures the distance between the sensor and an object by detecting
More informationplasmonic nanoblock pair
Nanostructured potential of optical trapping using a plasmonic nanoblock pair Yoshito Tanaka, Shogo Kaneda and Keiji Sasaki* Research Institute for Electronic Science, Hokkaido University, Sapporo 1-2,
More informationEE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:
EE119 Introduction to Optical Engineering Spring 2003 Final Exam Name: SID: CLOSED BOOK. THREE 8 1/2 X 11 SHEETS OF NOTES, AND SCIENTIFIC POCKET CALCULATOR PERMITTED. TIME ALLOTTED: 180 MINUTES Fundamental
More informationPANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: )
University of Minnesota College of Science and Engineering Characterization Facility PANalytical X pert Pro High Resolution Specular and Rocking Curve Scans User Manual (Version: 2012.10.17) The following
More informationSUPPLEMENTARY INFORMATION
SUPPLEMENTARY INFORMATION doi:10.1038/nature10864 1. Supplementary Methods The three QW samples on which data are reported in the Letter (15 nm) 19 and supplementary materials (18 and 22 nm) 23 were grown
More informationA Short History of Using Cameras for Weld Monitoring
A Short History of Using Cameras for Weld Monitoring 2 Background Ever since the development of automated welding, operators have needed to be able to monitor the process to ensure that all parameters
More informationFLAT FIELDS FOR FILTER WHEEL OFFSET POSITIONS
FLAT FIELDS FOR FILTER WHEEL OFFSET POSITIONS R. C. Bohlin, T. Wheeler, and J. Mack October 29, 2003 ABSTRACT The ACS filter wheel movements are accurate to one motor step, which leads to errors that exceed
More informationExamination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,
KTH Applied Physics Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy, 2009-06-05, 8-13, FB51 Allowed aids: Compendium Imaging Physics (handed out) Compendium Light Microscopy
More informationFabrication of large grating by monitoring the latent fringe pattern
Fabrication of large grating by monitoring the latent fringe pattern Lijiang Zeng a, Lei Shi b, and Lifeng Li c State Key Laboratory of Precision Measurement Technology and Instruments Department of Precision
More informationFull-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right
Quick Guide to Operating FEI Titan Themis G2 200 (S)TEM: TEM mode Susheng Tan Nanoscale Fabrication and Characterization Facility, University of Pittsburgh Office: M104/B01 Benedum Hall, 412-383-5978,
More informationNANO 703-Notes. Chapter 9-The Instrument
1 Chapter 9-The Instrument Illumination (condenser) system Before (above) the sample, the purpose of electron lenses is to form the beam/probe that will illuminate the sample. Our electron source is macroscopic
More informationExperimental Competition
37 th International Physics Olympiad Singapore 8 17 July 2006 Experimental Competition Wed 12 July 2006 Experimental Competition Page 2 List of apparatus and materials Label Component Quantity Label Component
More informationLaue diffraction software for reciprocal space data visualisation and analysis
Laue diffraction software for reciprocal space data visualisation and analysis Dr Gail N. Iles Neutrons 2.0: International Workshop Software for Neutron Scattering Berlin, Germany Tuesday 26th March 2013
More informationMuon detection in security applications and monolithic active pixel sensors
Muon detection in security applications and monolithic active pixel sensors Tracking in particle physics Gaseous detectors Silicon strips Silicon pixels Monolithic active pixel sensors Cosmic Muon tomography
More informationSUPPLEMENTARY INFORMATION
Optically reconfigurable metasurfaces and photonic devices based on phase change materials S1: Schematic diagram of the experimental setup. A Ti-Sapphire femtosecond laser (Coherent Chameleon Vision S)
More informationNature Protocols: doi: /nprot Supplementary Figure 1. Schematic diagram of Kőhler illumination.
Supplementary Figure 1 Schematic diagram of Kőhler illumination. The green beam path represents the excitation path and the red represents the emission path. Supplementary Figure 2 Microscope base components
More informationLOS 1 LASER OPTICS SET
LOS 1 LASER OPTICS SET Contents 1 Introduction 3 2 Light interference 5 2.1 Light interference on a thin glass plate 6 2.2 Michelson s interferometer 7 3 Light diffraction 13 3.1 Light diffraction on a
More informationReducing Proximity Effects in Optical Lithography
INTERFACE '96 This paper was published in the proceedings of the Olin Microlithography Seminar, Interface '96, pp. 325-336. It is made available as an electronic reprint with permission of Olin Microelectronic
More informationContrast transfer. Contrast transfer and CTF correction. Lecture 6 H Saibil
Lecture 6 H Saibil Contrast transfer Contrast transfer and CTF correction The weak phase approximation Contrast transfer function Determining defocus CTF correction methods Image processing for cryo microscopy
More informationGas scintillation Glass GEM detector for high-resolution X-ray imaging and CT
Gas scintillation Glass GEM detector for high-resolution X-ray imaging and CT Takeshi Fujiwara 1, Yuki Mitsuya 2, Hiroyuki Takahashi 2, and Hiroyuki Toyokawa 2 1 National Institute of Advanced Industrial
More informationElectron-Bombarded CMOS
New Megapixel Single Photon Position Sensitive HPD: Electron-Bombarded CMOS University of Lyon / CNRS-IN2P3 in collaboration with J. Baudot, E. Chabanat, P. Depasse, W. Dulinski, N. Estre, M. Winter N56:
More informationSome of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design)
Lens design Some of the important topics needed to be addressed in a successful lens design project (R.R. Shannon: The Art and Science of Optical Design) Focal length (f) Field angle or field size F/number
More informationUpgrade of the ultra-small-angle scattering (USAXS) beamline BW4
Upgrade of the ultra-small-angle scattering (USAXS) beamline BW4 S.V. Roth, R. Döhrmann, M. Dommach, I. Kröger, T. Schubert, R. Gehrke Definition of the upgrade The wiggler beamline BW4 is dedicated to
More informationRadial Polarization Converter With LC Driver USER MANUAL
ARCoptix Radial Polarization Converter With LC Driver USER MANUAL Arcoptix S.A Ch. Trois-portes 18 2000 Neuchâtel Switzerland Mail: info@arcoptix.com Tel: ++41 32 731 04 66 Principle of the radial polarization
More informationExperiment 1: Fraunhofer Diffraction of Light by a Single Slit
Experiment 1: Fraunhofer Diffraction of Light by a Single Slit Purpose 1. To understand the theory of Fraunhofer diffraction of light at a single slit and at a circular aperture; 2. To learn how to measure
More informationBruker D8 HRXRD Collecting X-Ray Reflectivity Data using the PathFinder Detector
Bruker D8 HRXRD Collecting X-Ray Reflectivity Data using the PathFinder Detector Abridged SOP for Manually Aligning a Sample and Collecting Data using XRD Commander Scott A Speakman, Ph.D. MIT Center for
More informationPolycapillary optic source combinations for protein crystallography
Journal of Applied Crystallography ISSN 0021-8898 Polycapillary optic source combinations for protein crystallography F. A. Hofmann, W. M. Gibson, C. A. MacDonald, D. A. Carter, J. X. Ho and J. R. Ruble
More informationAssessing ACS/WFC Sky Backgrounds
Instrument Science Report ACS 2012-04 Assessing ACS/WFC Sky Backgrounds Josh Sokol, Jay Anderson, Linda Smith July 31, 2012 ABSTRACT This report compares the on-orbit sky background levels present in Cycle
More informationDirect Contact Fiberoptic Plates for the Detection of Luminescent Cells
Direct Contact Fiberoptic Plates for the Detection of Luminescent Cells Prepared for Incom, Inc. By: Dr. David W. Stowe MinoTech Engineering Dr. Michael J. Minot Incom, Inc. October 30, 2007 INCOM, Inc.
More informationImprovement of terahertz imaging with a dynamic subtraction technique
Improvement of terahertz imaging with a dynamic subtraction technique Zhiping Jiang, X. G. Xu, and X.-C. Zhang By use of dynamic subtraction it is feasible to adopt phase-sensitive detection with a CCD
More informationSimulation comparisons of monitoring strategies in narrow bandpass filters and antireflection coatings
Simulation comparisons of monitoring strategies in narrow bandpass filters and antireflection coatings Ronald R. Willey Willey Optical, 13039 Cedar St., Charlevoix, Michigan 49720, USA (ron@willeyoptical.com)
More informationLaser Telemetric System (Metrology)
Laser Telemetric System (Metrology) Laser telemetric system is a non-contact gauge that measures with a collimated laser beam (Refer Fig. 10.26). It measure at the rate of 150 scans per second. It basically
More informationPackaging Fault Isolation Using Lock-in Thermography
Packaging Fault Isolation Using Lock-in Thermography Edmund Wright 1, Tony DiBiase 2, Ted Lundquist 2, and Lawrence Wagner 3 1 Intersil Corporation; 2 DCG Systems, Inc.; 3 LWSN Consulting, Inc. Addressing
More informationDigital Radiology with Photon Counting Detectors
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Digital Radiology with Photon Counting Detectors More Info at Open Access Database www.ndt.net/?id=16709
More informationPANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: )
University of Minnesota College of Science and Engineering Characterization Facility PANalytical X pert Pro Gazing Incidence X-ray Reflectivity User Manual (Version: 2012.10.17) The following instructions
More informationIMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2
KODAK for use with the KODAK CMOS Image Sensors November 2004 Revision 2 1.1 Introduction Choosing the right lens is a critical aspect of designing an imaging system. Typically the trade off between image
More informationLaser Beam Analysis Using Image Processing
Journal of Computer Science 2 (): 09-3, 2006 ISSN 549-3636 Science Publications, 2006 Laser Beam Analysis Using Image Processing Yas A. Alsultanny Computer Science Department, Amman Arab University for
More informationImproving the Collection Efficiency of Raman Scattering
PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution
More informationHigh Resolution Transmission Electron Microscopy (HRTEM) Summary 4/11/2018. Thomas LaGrange Faculty Lecturer and Senior Staff Scientist
Thomas LaGrange Faculty Lecturer and Senior Staff Scientist High Resolution Transmission Electron Microscopy (HRTEM) Doctoral Course MS-637 April 16-18th, 2018 Summary Contrast in TEM images results from
More informationControl of Noise and Background in Scientific CMOS Technology
Control of Noise and Background in Scientific CMOS Technology Introduction Scientific CMOS (Complementary metal oxide semiconductor) camera technology has enabled advancement in many areas of microscopy
More informationLaser Speckle Reducer LSR-3000 Series
Datasheet: LSR-3000 Series Update: 06.08.2012 Copyright 2012 Optotune Laser Speckle Reducer LSR-3000 Series Speckle noise from a laser-based system is reduced by dynamically diffusing the laser beam. A
More informationPixel Response Effects on CCD Camera Gain Calibration
1 of 7 1/21/2014 3:03 PM HO M E P R O D UC T S B R IE F S T E C H NO T E S S UP P O RT P UR C HA S E NE W S W E B T O O L S INF O C O NTA C T Pixel Response Effects on CCD Camera Gain Calibration Copyright
More informationRadiographic sensitivity improved by optimized high resolution X -ray detector design.
DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France Radiographic sensitivity improved by optimized high resolution X -ray detector
More informationSpatially Resolved Backscatter Ceilometer
Spatially Resolved Backscatter Ceilometer Design Team Hiba Fareed, Nicholas Paradiso, Evan Perillo, Michael Tahan Design Advisor Prof. Gregory Kowalski Sponsor, Spectral Sciences Inc. Steve Richstmeier,
More informationA 4 Megapixel camera with 6.5μm pixels, Prime BSI captures highly. event goes undetected.
PRODUCT DATASHEET Prime BSI SCIENTIFIC CMOS CAMERA Can a camera single-handedly differentiate your product against competitors? With the Prime BSI, the answer is a resounding yes. Instrument builders no
More informationWaveguiding in PMMA photonic crystals
ROMANIAN JOURNAL OF INFORMATION SCIENCE AND TECHNOLOGY Volume 12, Number 3, 2009, 308 316 Waveguiding in PMMA photonic crystals Daniela DRAGOMAN 1, Adrian DINESCU 2, Raluca MÜLLER2, Cristian KUSKO 2, Alex.
More informationTransmission electron Microscopy
Transmission electron Microscopy Image formation of a concave lens in geometrical optics Some basic features of the transmission electron microscope (TEM) can be understood from by analogy with the operation
More informationAmorphous Selenium Direct Radiography for Industrial Imaging
DGZfP Proceedings BB 67-CD Paper 22 Computerized Tomography for Industrial Applications and Image Processing in Radiology March 15-17, 1999, Berlin, Germany Amorphous Selenium Direct Radiography for Industrial
More informationCharge Loss Between Contacts Of CdZnTe Pixel Detectors
Charge Loss Between Contacts Of CdZnTe Pixel Detectors A. E. Bolotnikov 1, W. R. Cook, F. A. Harrison, A.-S. Wong, S. M. Schindler, A. C. Eichelberger Space Radiation Laboratory, California Institute of
More informationSTEM Spectrum Imaging Tutorial
STEM Spectrum Imaging Tutorial Gatan, Inc. 5933 Coronado Lane, Pleasanton, CA 94588 Tel: (925) 463-0200 Fax: (925) 463-0204 April 2001 Contents 1 Introduction 1.1 What is Spectrum Imaging? 2 Hardware 3
More informationSimulation of High Resistivity (CMOS) Pixels
Simulation of High Resistivity (CMOS) Pixels Stefan Lauxtermann, Kadri Vural Sensor Creations Inc. AIDA-2020 CMOS Simulation Workshop May 13 th 2016 OUTLINE 1. Definition of High Resistivity Pixel Also
More informationMode analysis of Oxide-Confined VCSELs using near-far field approaches
Annual report 998, Dept. of Optoelectronics, University of Ulm Mode analysis of Oxide-Confined VCSELs using near-far field approaches Safwat William Zaki Mahmoud We analyze the transverse mode structure
More informationThe new CMOS Tracking Camera used at the Zimmerwald Observatory
13-0421 The new CMOS Tracking Camera used at the Zimmerwald Observatory M. Ploner, P. Lauber, M. Prohaska, P. Schlatter, J. Utzinger, T. Schildknecht, A. Jaeggi Astronomical Institute, University of Bern,
More informationChapter Ray and Wave Optics
109 Chapter Ray and Wave Optics 1. An astronomical telescope has a large aperture to [2002] reduce spherical aberration have high resolution increase span of observation have low dispersion. 2. If two
More informationSupplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.
Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers. Finite-difference time-domain calculations of the optical transmittance through
More informatione2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions
e2v Launches New Onyx 1.3M for Premium Performance in Low Light Conditions e2v s Onyx family of image sensors is designed for the most demanding outdoor camera and industrial machine vision applications,
More informationNew Detectors for X-Ray Metal Thickness Measuring
ECNDT 2006 - Poster 132 New Detectors for X-Ray Metal Thickness Measuring Boris V. ARTEMIEV, Alexander I. MASLOV, Association SPEKTR- GROUP, Moscow, Russia Abstract. X-ray thickness measuring instruments
More informationPROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, Edited by
X - R A Y M I C R O S C O P Y A N D M I C R O R A D I O G R A P H Y PROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, 1956 Edited by V. E. COSSLETT Cavendish Laboratory, University
More information