PROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, Edited by
|
|
- Shon May
- 5 years ago
- Views:
Transcription
1 X - R A Y M I C R O S C O P Y A N D M I C R O R A D I O G R A P H Y PROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, 1956 Edited by V. E. COSSLETT Cavendish Laboratory, University of Cambridge, England ARNE ENGSTROM Department of Medical Physics, Karolinska Institutet, Stockholm, Sweden H. H. PATTEE, JR. Department of Physics, Stanford University, California 1957 ACADEMIC PRESS INC PUBLISHERS. NEW YORK
2 S7P- COPYRIGHT, 1957 BY ACADEMIC PRESS, INC. Ill FIFTH AVENUE NEW YORK 3, N.Y. ALL RIGHTS RESERVED NO PART OF THIS BOOK MAY BE REPRODUCED IN ANY FORM,BY PHOTOSTAT, MICROFILM, OR ANY OTHER MEANS, WITHOUT WRITTEN PERMISSION FROM THE PUBLISHERS LIBRARY OF CONGRESS CATALOG CARD NUMBER: s PRINTED IN THE UNITED STATES OF AMERICA
3 I A Scanning Microscope for X-Ray Emission Pictures P. DUNCUMB AND V. E. COSSLETT Cavendish Laboratory, Cambridge, England The purpose of the microscope is to form a picture of a surface by its X-ray emission and to analyze the elements in a selected volume of about one cubic micron in the surface by the characteristic lines emitted. This paper deals with the microscope, and some results of analysis are described on p It was convenient to develop the microscope first as a scanning projection microscope, somewhat similar to that proposed by Pattee (1), in order to have direct comparison with the normal projection microscope of Cosslett and Nixon (2). Figure 1 shows schematically the arrange- FIG. 1. Collection of X-rays in the scanning projection method. ment of the final lens with the electron beam scanned over the target by coils before the lens. The X-rays transmitted through each point in the specimen are detected by a counter after restriction by an aperture, and the amplified signal from the counter modulates the brightness of 374
4 X-RAY EMISSION SCANNING MICROSCOPE 375 a cathode-ray tube scanned in synchronism with the microscope beam. The screen, therefore, displays an absorption picture analogous to that from the static projection microscope. Clearly, it is best to put the specimen in contact with the target so that the counter aperture can be made as large as possible without spoiling the resolution. The intensity of each picture element is proportional to the number of quanta transmitted during the scanning time of the picture, and in order that the statistical fluctuation in this number shall not be visible, it must be greater than a certain minimum. With a screen of average brightness, the eye can just detect a change in brightness of about 15%, so that the statistical fluctuation must be less than this for a noise-free picture, and about 650 quanta per picture element are required. In order to collect sufficient quanta with a spot of 1 p and a copper target at 20 kv, it is necessary to use a counter aperture which subtends an angle of 2 at the target, and this gives a depth of focus for the specimen of 30 p. In practice, however, it is possible to put up with a picture showing some quantum noise on the screen and photograph it with an exposure time of several minutes to reduce the effect. An RCA electron microscope has been modified for projection scanning; the column was rebuilt with condenser and projector lenses only and reduced in length to about 80 cm. The counter first used was a scintillation counter using a sodium iodide crystal, and the picture was produced on a 6-in. cathode-ray tube with a long persistence screen at a scanning speed of about one picture in 2 sec. Figure 2 shows 200-mesh/in. copper grid and 800-mesh/in. silver grid photographed from the display screen. The thick bars of the finer grid are 6 p across, and the resolution is limited in this picture by the size of the spot on the display screen. The magnification was increased by reducing the area of scan of the microscope beam, and the same specimen then gave a resolution of about 2 p, limited by the diffusion of the electrons in the target. The accelerating voltage was 30 kv. The maximum area that could be scanned was about 0.4 mm square and the resolution is maintained out to the edges. Comparison with the static microscope showed that the scanning technique was satisfactory, and it appeared at first that the scanning projection microscope might have certain advantages over the static microscope. These are, first, that it can give a brighter picture than the fluorescent screen of the static microscope, and second, that it permits easy control of the contrast of the picture by electronic means. But it seemed, after some experiments, that neither of these features was sufficiently promising to pursue, and attention was therefore transferred to the emission method,
5 376 P. DUNCUMB AND V. E. COSSLETT In this mode of operation, the electrons strike the specimen directly and the X-rays emitted from each point are collected by the counter. If the specimen is thick, this must be done in the backward direction, but with a thin specimen, the X-rays may be collected along the axis as before, after passing through the specimen. There is now no restriction on the solid angle of X-rays collected, which can be as large as is practicable. A new final lens was designed to cope with both methods of collection and the emission microscope in its present form is shown in Fig. 3. FIG mesh/in. copper grid and 800 mesh/in. silver grid imaged by scanning projection method. 30 kv. Magnification 200 x. The electron beam is focused by two magnetic lenses on to the specimen O and is scanned over it by the deflection coils. These coils are similar to those used by McMullan and Smith in their scanning electron microscope (3) but give the beam a double deflection, balanced so that the beam always goes through the lens aperture. The spot size is 1 p and the area of scan about y 2 mm square at largest. Part of the emitted X-rays are collected through the gap in the pole piece by a scintillation counter S, and the amplified signal modulates the brightness of the display tube, which is scanned in synchronism with the microscope beam. When the picture is formed, the scan can be stopped and the microscope beam accurately located on any feature of the specimen by positioning
6 X-RAY EMISSION SCANNING MICROSCOPE 377 the spot on the afterglow of the picture on the display tube. Through another window, part of the emitted X-rays pass into a crystal spectrometer for analysis of the emission spectrum from the selected feature. Alternatively, the crystal can be removed and the X-rays pass straight into a proportional counter P, which gives for each quantum a pulse of height approximately proportional to its energy. Using a single-channel pulse analyzer, one can pass only pulses corresponding to a given characteristic line and, with the beam scanning, use these to form the picture on the display tube, so that the distribution of the element emitting that line is shown up. ffl Electron Gun Display ' > Amplifier Deflection Coils Time Bases Scint. Counter "Magnetic Lenses /Crystal Spectrometer may be inserted Prop. Counter Amplifier Specimen 0 Rate Meter Pulse Analyzer FIG. 3. The X-ray emission scanning microscope. The second lens is shown in Fig. 4. The electrons are focused on to the specimen which is level with the lower pole face, and X-rays pass through a window into a crystal phosphor just outside the pole-piece gap. The light produced passes down a perspex rod leading to the photocathode of the multiplier outside the lens. Alternatively, the X-rays can be collected along the axis of the beam in the case of a thin specimen or for the projection picture of a thin specimen. On the right-hand side, X-rays pass out through a tube filled with hydrogen into the spectrometer for analysis. The specimen is mounted on a tube gripped by two O rings and can be moved laterally by the screws below the lens, when the tube tilts about the upper O ring. The specimen tube can also be moved up or down and rotated; it is insulated from earth in order to measure the incident electron current. The focal length of the lens is about 4 mm; this is slightly shortened when a thick ferromagnetic speci-
7 378 P. DUNCUMB AND V. E. COSSLETT men is used, but the spot is not distorted. The top face of the lens is recessed so that the second set of deflection coils can be as close to the aperture as possible, to keep the electron beam within the uniform part of the field at large deflections. V Photo- % Multiplier g Specimen Movements FIG. 4. Final lens in the scanning emission microscope. The resolution is again limited by the penetration of the electrons, and Fig. 5 indicates the resolution obtainable at 10 kv to be about 1 p. It shows 1500-mesh/in. silver grid and the X-rays are collected after transmission through it along the axis. The width of the bars is about 3 p, and the dark line down the center of one set is presumably due to their triangular cross section, the center absorbing more strongly than the edges. As an example of the pulse-sorting technique with a proportional counter and pulse analyzer, Fig. 6 shows 200-mesh/in. copper grid and 800 mesh/in. silver taken at 20 kv. In A, the pulse analyzer was set to accept the AgL characteristic at 4 A, and the silver grid appears brighter than the copper. In B the pulse analyzer was passing CuK pulses at 1.5 A when the copper appears brighter than the silver. This demonstrates the possibility of showing up the distribution of one element only, but the energy resolution of the proportional counter is not good enough to be able to do this when the elements differ by less than about 4 in atomic number. However, some recent experiments indicate that there would be sufficient intensity reflected from a curved crystal in the spectrometer to form a noise-free picture, and this would easily be capable of separating adjacent elements.
8 X-RAY EMISSION SCANNING MICROSCOPE 379 FIG mesh/in. silver grid by the scanning emission method. 10 kv. Magnification 630 X. FIG mesh/in. copper grid and 800 mesh/in. silver. 20 kv. Magnification 300 X. A. Formed by AgL characteristic emission. B. Formed by CuK characteristic emission. Another way of displaying this same result is to regard Fig. 6 A and B as two components of a color picture and photograph them through different filters in register on the same piece of color film. Thus, if A is photographed with a green filter and B with a red, the silver comes out as green and the copper red. This was demonstrated. In principle one
9 ' 380 P. DUNCUMB AND V. E. COSSLETT can attach a given color to a given X-ray characteristic wavelength, which may be a useful technique for presenting in one picture the relative positions of different elements. The main points about the scanning emission microscope are therefore as follows: 1. It will produce a picture of a surface with contrast depending on the local variation of X-ray emission with a resolution of 1 p and a maximum field of view of about y 2 mm square. 2. It then enables one to position the electron beam very precisely on a selected point on the surface and to analyze the emitted X-rays with a crystal spectrometer. 3. Using a proportional counter or possibly a curved crystal spectrometer, it can show up the distribution of a particular element over the surface. Some applications of these techniques are given on p References 1. H. H. Pattee, /. Opt. Soc. Amer. 43, 61 (1953). 2. V. E. Cosslett and W. C. Nixon, /. Appl. Phys. 24, 616 (1953); W. C. Nixon, Proc. Roy. Soc. A232, 475 (1955). 3. D. McMullan, Proc. Inst. Elec. Engrs. 100, Pt. 1, 245 (1953); K. C. A. Smith and C. W. Oatley, Brit. J. Appl. Phys. 6, 391 (1955).
SCANNING ELECTRON MICROSCOPY By W. C. NIXON (Engineering Laboratory, Cambridge University)
213 0 Journal of the Royal MicroscopicalSociety, VoZ. 83, Pts. I & 2, June 1964. Pages 213-216 SCANNING ELECTRON MICROSCOPY By W. C. NIXON (Engineering Laboratory, Cambridge University) PLATE 97-98 AND
More informationS200 Course LECTURE 1 TEM
S200 Course LECTURE 1 TEM Development of Electron Microscopy 1897 Discovery of the electron (J.J. Thompson) 1924 Particle and wave theory (L. de Broglie) 1926 Electromagnetic Lens (H. Busch) 1932 Construction
More informationSecondary Electron Detector
Secondary Electron Detector Fig. 17 Everhart-Thornley Detector (Fig. 7-9, p. 215, Bozzola and Russell) Secondary electrons (SE) are attracted to Faraday cage because of its positive charge. Detector surface
More informationMODULE I SCANNING ELECTRON MICROSCOPE (SEM)
MODULE I SCANNING ELECTRON MICROSCOPE (SEM) Scanning Electron Microscope (SEM) Initially, the plan of SEM was offered by H. Stintzing in 1927 (a German patent application). His suggested procedure was
More information--> Buy True-PDF --> Auto-delivered in 0~10 minutes. JY/T
Translated English of Chinese Standard: JY/T011-1996 www.chinesestandard.net Sales@ChineseStandard.net INDUSTRY STANDARD OF THE JY PEOPLE S REPUBLIC OF CHINA General rules for transmission electron microscopy
More informationTransmission electron Microscopy
Transmission electron Microscopy Image formation of a concave lens in geometrical optics Some basic features of the transmission electron microscope (TEM) can be understood from by analogy with the operation
More informationModule 4B7: VLSI Design, Technology, and CAD. Scanning Electron Microscopical Examination of CMOS Integrated Circuit
Engineering Tripos Part IIB FOURTH YEAR Module 4B7: VLSI Design, Technology, and CAD Laboratory Experiment Dr D Holburn and Mr B Breton Scanning Electron Microscopical Examination of CMOS Integrated Circuit
More informationIntroduction: Why electrons?
Introduction: Why electrons? 1 Radiations Visible light X-rays Electrons Neutrons Advantages Not very damaging Easily focused Eye wonderful detector Small wavelength (Angstroms) Good penetration Small
More informationDETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response
DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response (response time) 5) Stability 6) Cost 7) convenience Photoelectric
More informationLaser Telemetric System (Metrology)
Laser Telemetric System (Metrology) Laser telemetric system is a non-contact gauge that measures with a collimated laser beam (Refer Fig. 10.26). It measure at the rate of 150 scans per second. It basically
More informationObserving Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros
PHARMACEUTICAL MICROBIOLOGY JIGAR SHAH INSTITUTE OF PHARMACY NIRMA UNIVERSITY Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens.
More informationNANO 703-Notes. Chapter 9-The Instrument
1 Chapter 9-The Instrument Illumination (condenser) system Before (above) the sample, the purpose of electron lenses is to form the beam/probe that will illuminate the sample. Our electron source is macroscopic
More informationVISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES
VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES Shortly after the experimental confirmation of the wave properties of the electron, it was suggested that the electron could be used to examine objects
More informationMedical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging
Medical Imaging X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging From: Physics for the IB Diploma Coursebook 6th Edition by Tsokos, Hoeben and Headlee And Higher Level Physics 2 nd Edition
More informationELECTRON MICROSCOPY AN OVERVIEW
ELECTRON MICROSCOPY AN OVERVIEW Anjali Priya 1, Abhishek Singh 2, Nikhil Anand Srivastava 3 1,2,3 Department of Electrical & Instrumentation, Sant Longowal Institute of Engg. & Technology, Sangrur, India.
More informationNanoSpective, Inc Progress Drive Suite 137 Orlando, Florida
TEM Techniques Summary The TEM is an analytical instrument in which a thin membrane (typically < 100nm) is placed in the path of an energetic and highly coherent beam of electrons. Typical operating voltages
More information(Refer Slide Time: 00:10)
Fundamentals of optical and scanning electron microscopy Dr. S. Sankaran Department of Metallurgical and Materials Engineering Indian Institute of Technology, Madras Module 03 Unit-6 Instrumental details
More informationIntroduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image
Introduction Chapter 16 Diagnostic Radiology Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther In diagnostic radiology
More informationTransmission Electron Microscopy 9. The Instrument. Outline
Transmission Electron Microscopy 9. The Instrument EMA 6518 Spring 2009 02/25/09 Outline The Illumination System The Objective Lens and Stage Forming Diffraction Patterns and Images Alignment and Stigmation
More informationScintillation Counters
PHY311/312 Detectors for Nuclear and Particle Physics Dr. C.N. Booth Scintillation Counters Unlike many other particle detectors, which exploit the ionisation produced by the passage of a charged particle,
More informationSCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS
SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS Robert Edward Lee Electron Microscopy Center Department of Anatomy and Neurobiology Colorado State University P T R Prentice Hall, Englewood Cliffs,
More informationScanning electron microscope
Scanning electron microscope 6 th CEMM workshop Maja Koblar, Sc. Eng. Physics Outline The basic principle? What is an electron? Parts of the SEM Electron gun Electromagnetic lenses Apertures Chamber and
More informationComponents of Optical Instruments
Components of Optical Instruments General Design of Optical Instruments Sources of Radiation Wavelength Selectors (Filters, Monochromators, Interferometers) Sample Containers Radiation Transducers (Detectors)
More informationChapter 2 The Study of Microbial Structure: Microscopy and Specimen Preparation
Chapter 2 The Study of Microbial Structure: Microscopy and Specimen Preparation 1 Lenses and the Bending of Light light is refracted (bent) when passing from one medium to another refractive index a measure
More informationOperating the Hitachi 7100 Transmission Electron Microscope Electron Microscopy Core, University of Utah
Operating the Hitachi 7100 Transmission Electron Microscope Electron Microscopy Core, University of Utah Follow the procedures below when you use the Hitachi 7100 TEM. Starting Session 1. Turn on the cold
More informationX-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope
X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope Kenichi Ikeda 1, Hideyuki Kotaki 1 ' 2 and Kazuhisa Nakajima 1 ' 2 ' 3 1 Graduate University for Advanced
More informationScanning electron microscope
Scanning electron microscope 5 th CEMM workshop Maja Koblar, Sc. Eng. Physics Outline The basic principle? What is an electron? Parts of the SEM Electron gun Electromagnetic lenses Apertures Detectors
More information880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser
880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser The goal of this lab is to give you experience aligning a laser and getting it to lase more-or-less from scratch. There is no write-up
More informationLife Science Chapter 2 Study Guide
Key concepts and definitions Waves and the Electromagnetic Spectrum Wave Energy Medium Mechanical waves Amplitude Wavelength Frequency Speed Properties of Waves (pages 40-41) Trough Crest Hertz Electromagnetic
More informationIntroduction to Scanning Electron Microscopy
Introduction to Scanning Electron Microscopy By: Brandon Cheney Ant s Leg Integrated Circuit Nano-composite This document was created as part of a Senior Project in the Materials Engineering Department
More informationBurton's Microbiology for the Health Sciences
Burton's Microbiology for the Health Sciences Chapter 2. Viewing the Microbial World Chapter 2 Outline Introduction Using the metric system to express the sizes of microbes Microscopes Simple microscopes
More informationChapter 2 Instrumentation for Analytical Electron Microscopy Lecture 7. Chapter 2 CHEM Fall L. Ma
Chapter 2 Instrumentation for Analytical Electron Microscopy Lecture 7 Outline Electron Sources (Electron Guns) Thermionic: LaB 6 or W Field emission gun: cold or Schottky Lenses Focusing Aberration Probe
More informationMSE 595T Transmission Electron Microscopy. Laboratory III TEM Imaging - I
MSE 595T Basic Transmission Electron Microscopy TEM Imaging - I Purpose The purpose of this lab is to: 1. Make fine adjustments to the microscope alignment 2. Obtain a diffraction pattern 3. Obtain an
More informationSECONDARY ELECTRON DETECTION
SECONDARY ELECTRON DETECTION CAMTEC Workshop Presentation Haitian Xu June 14 th 2010 Introduction SEM Raster scan specimen surface with focused high energy e- beam Signal produced by beam interaction with
More informationScanning Electron Microscopy. EMSE-515 F. Ernst
Scanning Electron Microscopy EMSE-515 F. Ernst 1 2 Scanning Electron Microscopy Max Knoll Manfred von Ardenne Manfred von Ardenne Principle of Scanning Electron Microscopy 3 Principle of Scanning Electron
More informationEE119 Introduction to Optical Engineering Fall 2009 Final Exam. Name:
EE119 Introduction to Optical Engineering Fall 2009 Final Exam Name: SID: CLOSED BOOK. THREE 8 1/2 X 11 SHEETS OF NOTES, AND SCIENTIFIC POCKET CALCULATOR PERMITTED. TIME ALLOTTED: 180 MINUTES Fundamental
More informationEnergy in Photons. Light, Energy, and Electron Structure
elearning 2009 Introduction Energy in Photons Light, Energy, and Electron Structure Publication No. 95007 Students often confuse the concepts of intensity of light and energy of light. This demonstration
More informationA DIGITIZING DEVICE FOR FILMLESS VISUAL DETECTORS. F. Villa Stanford Linear Accelerator Center ABSTRACT
-1- SS-7S 2100 A DIGITIZING DEVICE FOR FILMLESS VISUAL DETECTORS F. Villa Stanford Linear Accelerator Center ABSTRACT We describe a device for eliminating film as data storage for visual detectors. The
More informationChapter 18 Optical Elements
Chapter 18 Optical Elements GOALS When you have mastered the content of this chapter, you will be able to achieve the following goals: Definitions Define each of the following terms and use it in an operational
More informationX-ray Imaging. PHYS Lecture. Carlos Vinhais. Departamento de Física Instituto Superior de Engenharia do Porto
X-ray Imaging PHYS Lecture Carlos Vinhais Departamento de Física Instituto Superior de Engenharia do Porto cav@isep.ipp.pt Overview Projection Radiography Anode Angle Focal Spot Magnification Blurring
More informationChapter Ray and Wave Optics
109 Chapter Ray and Wave Optics 1. An astronomical telescope has a large aperture to [2002] reduce spherical aberration have high resolution increase span of observation have low dispersion. 2. If two
More informationTechnical Explanation for Displacement Sensors and Measurement Sensors
Technical Explanation for Sensors and Measurement Sensors CSM_e_LineWidth_TG_E_2_1 Introduction What Is a Sensor? A Sensor is a device that measures the distance between the sensor and an object by detecting
More informationNew 500 kv Electron Microscope
New 500 kv Electron Microscope B. T ADANO, H. KIMURA, S. KATAGIRI, M. NISHIGAKI Hitachi Central Research Laboratory, Kokubunji, Tokyo and R. UYEDA, Y. SAKAKI, S. MARUSE, K. MIHAMA, Y. KAMIYA Nagoya University,
More informationClass XII - Physics Wave Optics Chapter-wise Problems
Class XII - hysics Wave Optics Chapter-wise roblems Multiple Choice Question :- 10.1 Consider a light beam incident from air to a glass slab at Brewster s angle as shown in Fig. 10.1. A polaroid is placed
More informationRadiographic sensitivity improved by optimized high resolution X -ray detector design.
DIR 2007 - International Symposium on Digital industrial Radiology and Computed Tomography, June 25-27, 2007, Lyon, France Radiographic sensitivity improved by optimized high resolution X -ray detector
More informationOPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge
OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE by Doug Bray Department of Biological Sciences University of Lethbridge Revised September, 2000 Note: The terms in bold in this document represent
More informationMSE 460 TEM Lab 2: Basic Alignment and Operation of Microscope
MSE 460 TEM Lab 2: Basic Alignment and Operation of Microscope Last updated on 1/8/2018 Jinsong Wu, jinsong-wu@northwestern.edu Aims: The aim of this lab is to familiarize you with basic TEM alignment
More informationIntroduction To NDT. BY: Omid HEIDARY
Introduction To NDT BY: Omid HEIDARY NDT Methods Penetrant Testing Magnetic Particle Testing Eddy Current Testing Ultrasonic Testing Radiographic Testing Acoustic Emission Infrared Testing Visual Testing
More informationBASICS OF FLUOROSCOPY
Medical Physics Residents Training Program BASICS OF FLUOROSCOPY Dr. Khalid Alyousef, PhD Department of Medical Imaging King Abdulaziz Medical City- Riyadh Edison examining the hand of Clarence Dally with
More informationNAME SECTION PERFORMANCE TASK # 3. Part I. Qualitative Relationships
NAME SECTION PARTNERS DATE PERFORMANCE TASK # 3 You must work in teams of three or four (ask instructor) and will turn in ONE report. Answer all questions. Write in complete sentences. You must hand this
More informationProcedures for Performing Cryoelectron Microscopy on the FEI Sphera Microscope
Procedures for Performing Cryoelectron Microscopy on the FEI Sphera Microscope The procedures given below were written specifically for the FEI Tecnai G 2 Sphera microscope. Modifications will need to
More informationLlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points
WRITE ON SCANTRON WITH NUMBER 2 PENCIL DO NOT WRITE ON THIS TEST LlIGHT REVIEW PART 2 DOWNLOAD, PRINT and submit for 100 points Multiple Choice Identify the choice that best completes the statement or
More informationINTRODUCTION THIN LENSES. Introduction. given by the paraxial refraction equation derived last lecture: Thin lenses (19.1) = 1. Double-lens systems
Chapter 9 OPTICAL INSTRUMENTS Introduction Thin lenses Double-lens systems Aberrations Camera Human eye Compound microscope Summary INTRODUCTION Knowledge of geometrical optics, diffraction and interference,
More informationInstruction Manual T Binocular Acromat Research Scope T Trinocular Acromat Research Scope
Research Scope Instruction Manual T-29031 Binocular Acromat Research Scope T-29041 Trinocular Acromat Research Scope T-29032 Binocular Semi-Plan Research Scope T-29042 Trinocular Semi-Plan Research Scope
More informationOscilloscope Measurements
PC1143 Physics III Oscilloscope Measurements 1 Purpose Investigate the fundamental principles and practical operation of the oscilloscope using signals from a signal generator. Measure sine and other waveform
More informationLECTURE 1 The Radiographic Image
LECTURE 1 The Radiographic Image Prepared by:- KAMARUL AMIN ABDULLAH @ ABU BAKAR UiTM Faculty of Health Sciences Medical Imaging Department 11/23/2011 KAMARUL AMIN (C) 1 Lesson Objectives At the end of
More information2. Raise HT to 200kVby following the procedure explained in 1.6.
JEOL 2100 MANUAL Quick check list 1. If needed, fill the reservoir with LN2 2. Raise HT to 200kVby following the procedure explained in 1.6. 3. Insert specimen holder into TEM (Insert holder in airlock,
More informationPhysics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: Signature:
Physics 431 Final Exam Examples (3:00-5:00 pm 12/16/2009) TIME ALLOTTED: 120 MINUTES Name: PID: Signature: CLOSED BOOK. TWO 8 1/2 X 11 SHEET OF NOTES (double sided is allowed), AND SCIENTIFIC POCKET CALCULATOR
More informationChapter 25. Optical Instruments
Chapter 25 Optical Instruments Optical Instruments Analysis generally involves the laws of reflection and refraction Analysis uses the procedures of geometric optics To explain certain phenomena, the wave
More informationA Pa UNITED STATES. November 1956 [TISE Issuance Date] David Sarnoff Research Center Princeton, New Jersey
UNCLASSIFIED RIB-17 A Pa, PR I 1958 UNITED STATES ATOMIC ; ^ rc ENERGY INSTRUMENTATION COMMISSION ELECTRONIC DEVICES FOR NUCLEAR PHYSICS; A REPORT ON PHOTOMULTIPLIER TUBE DEVELOPMENT Quarterly Report No.
More informationECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the
ECEN 4606 Lab 8 Spectroscopy SUMMARY: ROBLEM 1: Pedrotti 3 12-10. In this lab, you will design, build and test an optical spectrum analyzer and use it for both absorption and emission spectroscopy. The
More informationELECTRON MICROSCOPY. 13:10 16:00, Oct. 6, 2008 Institute of Physics, Academia Sinica. Tung Hsu
ELECTRON MICROSCOPY 13:10 16:00, Oct. 6, 2008 Institute of Physics, Academia Sinica Tung Hsu Department of Materials Science and Engineering National Tsing Hua University Hsinchu 300, TAIWAN Tel. 03-5742564
More informationSchematic diagram of the DAP
Outline Introduction Transmission mode measurement results Previous emission measurement Trapping mechanics Emission measurement with new circuits Emission images Future plan and conclusion Schematic diagram
More informationTecnai on-line help manual --
Tecnai on-line help Alignments 1 Tecnai on-line help manual -- Alignments Table of Contents 1 Alignments in the Tecnai microscope...5 2 Alignment procedures...6 3 Introduction to electron optics...11 3.1
More informationUser Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com
User Manual Digital Compound Binocular LED Microscope Model MD82ES10 MicroscopeNet.com Table of Contents i. Caution... 1 ii. Care and Maintenance... 2 1. Components Illustration... 3 2. Installation...
More informationLight Microscopy. Upon completion of this lecture, the student should be able to:
Light Light microscopy is based on the interaction of light and tissue components and can be used to study tissue features. Upon completion of this lecture, the student should be able to: 1- Explain the
More informationChapter 36. Image Formation
Chapter 36 Image Formation Image of Formation Images can result when light rays encounter flat or curved surfaces between two media. Images can be formed either by reflection or refraction due to these
More informationChapter 36. Image Formation
Chapter 36 Image Formation Notation for Mirrors and Lenses The object distance is the distance from the object to the mirror or lens Denoted by p The image distance is the distance from the image to the
More informationCHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES
CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES The current multiplication mechanism offered by dynodes makes photomultiplier tubes ideal for low-light-level measurement. As explained earlier, there
More informationMaltase cross tube. D. Senthilkumar P a g e 1
Thermionic Emission Maltase cross tube Definition: The emission of electrons when a metal is heated to a high temperature Explanation: In metals, there exist free electrons which are able to move around
More informationRADIOGRAPHIC EXPOSURE
RADIOGRAPHIC EXPOSURE Receptor Exposure Receptor Exposure the that interacts with the receptor. Computed Radiography ( ) requires a. Direct Digital Radiography (DR) requires a. Exposure Indicators Exposure
More informationX-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage
X-rays Ouch! 1 X-rays X-rays are produced when electrons are accelerated and collide with a target Bremsstrahlung x-rays Characteristic x-rays X-rays are sometimes characterized by the generating voltage
More informationNanotechnology and material science Lecture V
Most widely used nanoscale microscopy. Based on possibility to create bright electron beam with sub-nm spot size. History: Ernst Ruska (1931), Nobel Prize (1986) For visible light λ=400-700nm, for electrons
More informationp q p f f f q f p q f NANO 703-Notes Chapter 5-Magnification and Electron Sources
Chapter 5-agnification and Electron Sources Lens equation Let s first consider the properties of an ideal lens. We want rays diverging from a point on an object in front of the lens to converge to a corresponding
More informationPhysics Laboratory Scattering of Photons from Electrons: Compton Scattering
RR Oct 2001 SS Dec 2001 MJ Oct 2009 Physics 34000 Laboratory Scattering of Photons from Electrons: Compton Scattering Objective: To measure the energy of high energy photons scattered from electrons in
More informationAQA P3 Topic 1. Medical applications of Physics
AQA P3 Topic 1 Medical applications of Physics X rays X-ray properties X-rays are part of the electromagnetic spectrum. X-rays have a wavelength of the same order of magnitude as the diameter of an atom.
More informationThe arrangement of the instrument is illustrated in the diagrams opposite.
Sectional view Plan view General description This is a direct reading instrument for measuring transmission densities of ordinary photographic negatives. Visual observation of the photometric fields is
More informationChapter Wave Optics. MockTime.com. Ans: (d)
Chapter Wave Optics Q1. Which one of the following phenomena is not explained by Huygen s construction of wave front? [1988] (a) Refraction Reflection Diffraction Origin of spectra Q2. Which of the following
More information1.3. Before loading the holder into the TEM, make sure the X tilt is set to zero and the goniometer locked in place (this will make loading easier).
JEOL 200CX operating procedure Nicholas G. Rudawski ngr@ufl.edu (805) 252-4916 1. Specimen loading 1.1. Unlock the TUMI system. 1.2. Load specimen(s) into the holder. If using the double tilt holder, ensure
More informationGeneral Physics II. Ray Optics
General Physics II Ray Optics 1 Dispersion White light is a combination of all the wavelengths of the visible part of the electromagnetic spectrum. Red light has the longest wavelengths and violet light
More informationScanning Electron Microscopy SEM. Warren Straszheim, PhD MARL, 23 Town Engineering
Scanning Electron Microscopy SEM Warren Straszheim, PhD MARL, 23 Town Engineering wesaia@iastate.edu 515-294-8187 How it works Create a focused electron beam Accelerate it Scan it across the sample Map
More informationNumerical analysis to verifying the performance of condenser magnetic lens in the scanning electron microscope.
Numerical analysis to verifying the performance of condenser magnetic lens in the scanning electron microscope. Mohammed Abdullah Hussein Dept. of mechanization and agricultural equipment, College of agriculture
More informationANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER
Copyright(c)JCPDS-International Centre for Diffraction Data 2001,Advances in X-ray Analysis,Vol.44 325 ANALYTICAL MICRO X-RAY FLUORESCENCE SPECTROMETER ABSTRACT William Chang, Jonathan Kerner, and Edward
More informationAtomic and nuclear physics
Atomic and nuclear physics X-ray physics Physics of the atomic shell LEYBOLD Physics Leaflets Investigating the energy spectrum of an x-ray tube as a function of the high voltage and the emission current
More informationApplications of Optics
Nicholas J. Giordano www.cengage.com/physics/giordano Chapter 26 Applications of Optics Marilyn Akins, PhD Broome Community College Applications of Optics Many devices are based on the principles of optics
More informationRecent results from the JEOL JEM-3000F FEGTEM in Oxford
Recent results from the JEOL JEM-3000F FEGTEM in Oxford R.E. Dunin-Borkowski a, J. Sloan b, R.R. Meyer c, A.I. Kirkland c,d and J. L. Hutchison a a b c d Department of Materials, Parks Road, Oxford OX1
More informationDesign and Application of a Quadrupole Detector for Low-Voltage Scanning Electron Mcroscopy
SCANNING Vol. 8, 294-299 (1986) 0 FACM. Inc. Received: August 29, 1986 Original Paper Design and Application of a Quadrupole Detector for Low-Voltage Scanning Electron Mcroscopy R. Schmid and M. Brunner"
More informationTest Review # 8. Physics R: Form TR8.17A. Primary colors of light
Physics R: Form TR8.17A TEST 8 REVIEW Name Date Period Test Review # 8 Light and Color. Color comes from light, an electromagnetic wave that travels in straight lines in all directions from a light source
More informationChapter 16 Light Waves and Color
Chapter 16 Light Waves and Color Lecture PowerPoint Copyright The McGraw-Hill Companies, Inc. Permission required for reproduction or display. What causes color? What causes reflection? What causes color?
More informationVisibility of Detail
Visibility of Detail Radiographic Quality Quality radiographic images represents the, and information is for diagnosis. The of the anatomic structures and the accuracy of their ( ) determine the overall
More informationMultiple Choice Identify the letter of the choice that best completes the statement or answers the question.
RA110 test 3 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. An object 35 cm in width is radiographed at 100 cm SID and at a 50 cm SOD. What
More informationX-rays in medical diagnostics
X-rays in medical diagnostics S.Dolanski Babić 2017/18. History W.C.Röntgen (1845-1923) discovered a new type of radiation Nature, Jan. 23. 1896.; Science, Feb.14. 1896. X- rays: Induced the ionization
More informationPh 3455 The Photoelectric Effect
Ph 3455 The Photoelectric Effect Required background reading Tipler, Llewellyn, section 3-3 Prelab Questions 1. In this experiment you will be using a mercury lamp as the source of photons. At the yellow
More informationExam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.
Name: Class: Date: Exam 4 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. Mirages are a result of which physical phenomena a. interference c. reflection
More informationX-ray Tube and Generator Basic principles and construction
X-ray Tube and Generator Basic principles and construction Dr Slavik Tabakov - Production of X-rays and Patient Dose OBJECTIVES - X-ray tube construction - Anode - types, efficiency - Classical X-ray generator
More informationLEO 912 TEM Short Manual. Prepared/copyrighted by RH Berg Danforth Plant Science Center
LEO 912 TEM Short Manual Prepared/copyrighted by RH Berg Danforth Plant Science Center Specimen holder [1] Never touch the holder (outside of the O-ring, double-headed arrow) because finger oils will contaminate
More informationBasic Users Manual for Tecnai-F20 TEM
Basic Users Manual for Tecnai-F20 TEM NB: This document contains my personal notes on the operating procedure of the Tecnai F20 and may be used as a rough guide for those new to the microscope. It may
More informationEE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:
EE119 Introduction to Optical Engineering Spring 2003 Final Exam Name: SID: CLOSED BOOK. THREE 8 1/2 X 11 SHEETS OF NOTES, AND SCIENTIFIC POCKET CALCULATOR PERMITTED. TIME ALLOTTED: 180 MINUTES Fundamental
More informationLow Voltage Electron Microscope
LVEM5 Low Voltage Electron Microscope Nanoscale from your benchtop LVEM5 Delong America DELONG INSTRUMENTS COMPACT BUT POWERFUL The LVEM5 is designed to excel across a broad range of applications in material
More informationECEN 4606, UNDERGRADUATE OPTICS LAB
ECEN 4606, UNDERGRADUATE OPTICS LAB Lab 2: Imaging 1 the Telescope Original Version: Prof. McLeod SUMMARY: In this lab you will become familiar with the use of one or more lenses to create images of distant
More information