DETAILS KOMPROMENT DANISH BUILDING DESIGN ZAPPA

Size: px
Start display at page:

Download "DETAILS KOMPROMENT DANISH BUILDING DESIGN ZAPPA"

Transcription

1 DETAILS KOMPROMENT DANISH BUILDING DESIGN ZAPPA

2 Z-0 - Elevation : 0 At the bottom, the first batten must be mounted according to detal Z- Slate size Batten distance 00 x 00 mm 0 mm -0, + 0 x 00 mm 0 mm -0, + 00 x 00 mm 0 mm -0, + Natural slate - mm Barcelona silver white Mounting clips, stainless steel 00 system batten Moist- and UV-resistant mm counter batten Z-0 - Cut : 00 Z-0 - Natural slate 00 x 00 mm ZAPPA system Date: Z-0 : 0 As indicated Tlf: Fax: + 90

3 Natural slate - mm, UH Barcelona silver white mounting clips mm system batten Counter batten mm Batten distance 0-0, + Overlay 0 Slate height 00 Slate size Batten distance 00 x 00 mm 0 mm -0, + 0 x 00 mm 0 mm -0, + 00 x 00 mm 0 mm -0, + Vertical Cut Date: Z- : Tlf: Fax: + 90

4 Natural slate - mm, UH Barcelona silver white system batten mounting clips mm Counter batten mm Horizontal cut Date: Z- : Tlf: Fax: + 90

5 8 9 Bottom window Top window/door window flashing bottom/side Natural slate - mm, UH Barcelona Silver White Façade adhesive system batten Trimmed mounting clips mounting clips Natural slate - mm, UH Barcelona Silver White system nail Counter batten mm system batten system nail Counter batten mm Drainage gutter - mechanically fixed and sealed Start batten + start clips 8 Façade adhesive 9 Window flashing top/side Window / door - Vertical cut Date: Z- : Tlf: Fax: + 90

6 Natural slate - mm, UH Barcelona Silver white system batten mounting clips Counter batten mm Façade adhesive Window flashing bottom/side Window / door - Horizontal cut Date: Z- : Tlf: Fax: + 90

7 Trimmed mounting clips Natural slate - mm, UH Barcelona Silver white mounting clips system batten Counter batten mm Connection roof/facade v. Date: Z- : Tlf: Fax: + 90

8 8 Ventilated roof construction Aluminium profile (Project specified) Trimmed mounting clips Counterbatten mm system batten mounting clips 8 Natural slate - mm, UH Barcelona Silver White Connection roof/facade v. Date: Z- : Tlf: Fax: + 90

9 Natural slate - mm, UH Barcelona Silver White Counter batten mm mounting clips system batten start clips start batten Start façade Date: Z- : Tlf: Fax: + 90

10 8 Top elements (project specified) Ventilated roof construction Trimmed mounting clips Natural slate - mm, UH Barcelona Silver White Counter batten mm mounting clips 8 system batten With air vent. Date: Z-8 : Tlf: Fax: + 90

11 Top elements (Project specified) Trimmed mounting clips Natural slate - mm, UH Barcelona Silver White Counter batten mm mounting clips system batten Without air vent. Date: Z-9 : Tlf: Fax: + 90

12 Natural slate - mm, UH Barcelona Silver white system batten mounting clips Counter batten mm Corner profile aluminium mounted on counter battens per 0 mm Element for seperating facades (wind stop) External corner with alu profile Date: Z-0 : Tlf: Fax: + 90

13 Natural slate - mm, UH Barcelona Silver white mounting clips system batten Counter batten mm Corner profile aluminium mounted on counter battens per 0 mm Element for seperating facades (wind stop) Internal corner with alu profile Date: Z- : Tlf: Fax: + 90

Details KOMPROMENT. Danish Building Design D-WALL

Details KOMPROMENT. Danish Building Design D-WALL Details KOMPROMENT Danish Building Design X X X X X X Elevation : 0 Batten Distance: Slate size: X X At the bottom, the first batten must be mounted according to detail D-7 00x00 mm 0 mm mm 0x00 mm 0 mm

More information

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc.

Installation Instruction 3-D Model 3D 03/01/17. 0 Flush Siding Horizontal System N/C WPS, Inc. I B D L K C E G M F A H J Installation Instruction 3-D Model 3D 03/01/17 Detail: System Type: Scale: Drawn By: 0 Flush Siding Horizontal System N/C WPS, Inc. Wall Panel System, Inc. 15/16" 1 1/4" Bottom

More information

Installation guide for 20/20

Installation guide for 20/20 Introduction The following installation instructions are recommended minimum requirements for the 20/20. The designer and fixer should ensure that tiles are installed in accordance with BS 5534; The British

More information

Ventilated tile façades

Ventilated tile façades Ventilated tile façades xxxxxxxx 3 Vidar - Clay Shingles 5 ZAPPA - natural slate 21 D Wall - natural slate 37 Climate Cover - natural slate 41 SOLAR CELLS - INTEGRATED IN THE FAÇADE 45 Vidar - Clay Shingles

More information

Ventilated tile façades

Ventilated tile façades Ventilated tile façades XXXXXXXX 3 VIDAR - CLAY SHINGLES 5 ZAPPA - NATURAL SLATE 21 D WALL - NATURAL SLATE 37 CLIMATE COVER - NATURAL SLATE 41 SOLAR CELLS - INTEGRATED IN THE FAÇADE 45 VIDAR - CLAY SHINGLES

More information

Installation Guide Classic Series Wood Siding

Installation Guide Classic Series Wood Siding Installation Guide Classic Series Wood Siding Please read the following instructions prior to beginning your installation. The following installation guidelines have been produced in accordance with the

More information

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit

C.00. Ullrich Aluminium Co. Ltd. Ulltraclad Aluminium Cladding September Wall Batten Elevation. Horizontal battens between verticals at soffit Horizontal battens between verticals at soffit 2 C.04 600 600 600 600 Cavity batten at 600 mm centres 1 C.03 Batten fixing points 1 C.04 1 C.07 1 C.12 1 C.13 1 C.14 Meter Box Window 1 C.08 1 C.09 800 800

More information

Multi-layer Insulation Blanket for Roofs, Walls & Floors The Highest Performing Certificated MultiFoil on the Market

Multi-layer Insulation Blanket for Roofs, Walls & Floors The Highest Performing Certificated MultiFoil on the Market Multilayer Insulation Blanket for Roofs, Walls & Floors e The Highest Performing Certificated MultiFoil on the Market MultifoilInsulation.com UK and European Distributors Specialising in Multifoil Insulation

More information

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs. Plank joint 600mm stud crs 600mm 600mm 600mm Horizontal Structural Timber Cavity atten 50x20mm H3.1 atten fixing points 800mm 800mm 300mm 800mm Max. Nog spacing 50mm All intermediate battens to be 50x20mm

More information

Installation Guide - Evolution Series Wood Siding

Installation Guide - Evolution Series Wood Siding Installation Guide - Evolution Series Wood Siding The following instructions pertain to the installation of Fraser Wood Siding Evolution Series on a typical wood frame construction allowing for nail penetration

More information

Technical Note No. 028

Technical Note No. 028 Technical Note No. 028 38 Series Strand Substrate for Board & Batten Applications This Technical Note provides guidance for the application of 38 Series Strand Substrate for Board & Batten Applications.

More information

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS External EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS Parklex Facade may be installed using mechanical fasteners, such as screws or rivets. The panels are attached to vertical battens. In the event that

More information

NEW equinox INSTALLATION GUIDE Issue

NEW equinox INSTALLATION GUIDE Issue NEW equinox INSTALLATION GUIDE Issue 1 CONTENTS If in doubt at any stage 1. Preparing the ring beam 2 2. Installing the framework 3 3. Insulation and waterproofing 7 4. Tile application: Steel tiles 9

More information

8000 SERIES SLIDER - 2 LITE (DUAL SLIDE) (ELEVATION DRAWING)

8000 SERIES SLIDER - 2 LITE (DUAL SLIDE) (ELEVATION DRAWING) - 2 LITE (DUAL SLIDE) (ELEVATION DRAWING) HEAD (MEETING RAIL) NOTE: ELEVATION VIEWED FROM THE OUTSIDE LOOKING IN. ELEVATION DRAWING 3" = 1' - 0" SL1.1 - 3 LITE (END VENT) (ELEVATION DRAWING) HEAD 3 LITE

More information

Installation Guide GRP Dormer

Installation Guide GRP Dormer Installation Guide GRP Dormer To ensure optimum performance please follow the correct fitting procedures outlined in this installation guide. Site safety and good building practice should be adhered to

More information

Concrete Log Siding Material Estimate Worksheet

Concrete Log Siding Material Estimate Worksheet Thank you for your interest in ClearCreek Concrete Log Siding. 4436 W. Manufacturers Street Springfield, MO 65803 Phone: (800) 862-6088 www.crosstechcp.com www.clearcreeksiding.com Concrete Log Siding

More information

manthorpe Roll-Out Dry Fix Ridge System building products Fixing Instructions MBP 8265e

manthorpe Roll-Out Dry Fix Ridge System building products Fixing Instructions MBP 8265e manthorpe building products Roll-Out Dry Fix Ridge System Fixing Instructions MBP 8265e Ridge Details Fig A. Assembly View of Dry Ridge Detail s/s screw clamping plate rubber washer foam spacer ridge tile

More information

REDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions

REDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions REDLAND DRY VALLEY Installation Instructions for Redland Dry Valley Version: 6 Date: May 2013 Author: Department: Redland Technical Solutions Redland Technical Solutions 1 Introduction 1.1 TECHNICAL DATA

More information

40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)

40mm Thermoclick.  Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories

More information

Technical Note No. 026

Technical Note No. 026 Technical Note No. 026 Strand Substrate Installed Vertically for Board & or Board-on-Board Applications This Technical Note is an addendum to the Strand Substrate Application Instructions and Trim and

More information

YWY M08 The new VELUX solution

YWY M08 The new VELUX solution YWY M08 The new VELUX solution VELUX roof windows and vertical window elements installed as a dormer in roof pitches between 42º and 52º YWY M08 is available as a double or triple unit and can be installed

More information

1. Tile Roof Installation:!

1. Tile Roof Installation:! 1. Tile Roof Installation:! * Solar Roof Fan have a different base plate and ventilation opening size. This will require different measurements and allowances to those shown as pictures. Materials Needed:

More information

Roll-Fix Kit The complete dry hip kit RFIG

Roll-Fix Kit The complete dry hip kit RFIG H I P Roll-Fix Kit The complete dry hip kit RFIG.045-0906-1 Roll-Fix is a quick and simple dry-fix roofing kit for hips. l Quick and easy to install no special tools required l Universal application fits

More information

IMAGINATION SOLAR LTD. Installation Guide A1. Planning The Collector Installation

IMAGINATION SOLAR LTD. Installation Guide A1. Planning The Collector Installation Page 1 of 6 IMAGINATION SOLAR LTD Installation Guide A1 Planning The Collector Installation Unit 4 Montpelier Central, Station Road Bristol BS6 5EE t: 0117 943 6668 f: 0117 942 8998 e: enquiries@imaginationsolar.com

More information

Installing Novi Siding Trim

Installing Novi Siding Trim Installing Novi Siding Trim CAUTION: Remember that polymer undergoes expansion/contraction due to variations in temperature. The following instructions will allow for the expansion/contraction of the material.

More information

AQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM

AQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM AQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM The following guide covers the technique for the Mechanically Fixed System. This system is best employed when an overlay

More information

Metal Roof Installation Manual. Chapter 5: Panel Attributes/Profiles

Metal Roof Installation Manual. Chapter 5: Panel Attributes/Profiles Metal Roof Installation Manual Chapter 5: Panel Attributes/Profiles Chapter 5: Panel Attributes/Profiles Chapter Contents 5. Panel Attributes / Profiles... 5-1 5.1 Widths... 5-1 5.2 Ribs... 5-2 5.2.1 Rib

More information

Greenhouse Assembly Instructions

Greenhouse Assembly Instructions Greenhouse Assembly Instructions Our Help Line provides support and advice to customers of Summer Garden Buildings after ordering. For advice before you buy you can phone us free 7 days a week on 0800

More information

How many tiles can you see?

How many tiles can you see? www.lafarge-roofing.co.uk Customer Service Hotline For all sales enquiries/orders, call or fax our dedicated Customer Service Hotline and you will be connected to the internal sales representative dealing

More information

Assembly instructions

Assembly instructions Assembly instructions Plannja Profiles 20 105, 20 75, Sinus 18, Sinus 51, 45, 45R, 19R, 35 including flashings and fittings 2017 Roofing Sheet & Wall Cladding TABLE OF CONTENTS Some words of advice...

More information

Roof fastener. Perfectly thought out for every roof

Roof fastener. Perfectly thought out for every roof Roof fastener Perfectly thought out for every roof 1 Welcome to the world of clever solutions Solutions for every roof In our production areas we produce all needed components for the sub construction

More information

Installation. Openings: Valley: Installation on timber roofs (new buildings) 1. Fit a support (noggins) around the opening.

Installation. Openings: Valley: Installation on timber roofs (new buildings) 1. Fit a support (noggins) around the opening. Installation Openings: 1. Fit a support (noggins) around the opening. 2. Apply Isola Sealant to the support and then fit Pro Super. 3. Install an Isola Opening Fitting for round or square openings. (Remember

More information

Installation Instructions of HomeTech Fakro Skylights

Installation Instructions of HomeTech Fakro Skylights Installation Instructions of HomeTech Fakro Skylights EH Flashing Suitable for corrugated, concrete tile and pressed metal tile roof types 15-75 For roofs with minimum pitch 15 and maximum pitch 75 IMPORTANT:

More information

Gardman Lean-to Greenhouse Assembly Instructions

Gardman Lean-to Greenhouse Assembly Instructions Page 1 Gardman Lean-to Greenhouse Assembly Instructions Our Help Line provides support and advice to customers of Summer Garden Buildings after ordering. For advice before you buy you can phone us free

More information

System for 2+ Level Buildings

System for 2+ Level Buildings Issued Sept 205 Contact Info@symonite.co.nz System for 2+ Level Buildings Typical Details Issued: September 205 TYPICAL DETAILS CONTENTS.0 TYPICAL VERTICAL JOINTS 2.0 EXT. CORNER / TYPICAL HORIZONTAL JOINT

More information

Series 525 LouvreMASTER Adjustable Louvre Window

Series 525 LouvreMASTER Adjustable Louvre Window Series 525 LouvreMASTER Adjustable Louvre Window DESIGNER SERIES Photo courtesy of Hanlon Windows Australia DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 DESIGNER SERIES Series 525 KEY EATURES / PERORMANCE

More information

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.

Ulltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4. Ulltraclad Aluminium Cladding Contents 1.0 General Information 2 2.0 Design Information 4 3.0 Installation Information 7 4.0 Maintenance 10 5.0 Health & Safety 10 1 1.0 General Information 1.1 Introduction

More information

SIDING INSTALLATION GUIDE

SIDING INSTALLATION GUIDE READ THIS ENTIRE GUIDE CAREFULLY BEFORE INSTALLING NOBELIA SIDING. This installation guide applies to all NOBELIA siding profiles, including SPF tongue-and-groove and exposed nail siding. IMPORTANT: FAILURE

More information

APRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL

APRON FLASHING NOTES: SHEET METAL APRON FLASHING WITH HEMMED EDGE RAGGLE SEALANT UNDERLAYMENT TURNED UP WALL SHEET METAL APRON FLASHING WITH HEMMED EDGE SEALANT SHEET METAL COUNTERFLASHING (SEE NOTE No.1) RAGGLE UNDERLAYMENT TURNED UP WALL SHEET METAL STEP FLASHING SOLDER OR SEAL CORNERS ASPHALT SHINGLES NOTES:

More information

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights

1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and Highlights 1 Exam Prep NRCA Roofing Manual: Steep-Slope Roof Systems 2013 Tabs and s These 1 Exam Prep Tabs are based on the National Roofing Contractors Association (NRCA) manual listed below: Steep-Slope Roof Systems

More information

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS www.capecodsiding.com INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS IMPORTANT READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE INSTALLING YOUR WOOD SIDING. FAILURE TO STRICTLY FOLLOW THESE INSTALLATION,

More information

NEW equinox INSTALLATION GUIDE Issue

NEW equinox INSTALLATION GUIDE Issue NEW equinox INSTALLATION GUIDE Issue 2 CONTENTS 1. Preparing the ring beam 2 2. Installing the framework 3 3. How to install structural support posts 7 4. Insulation and waterproofing 8 5. Tile application:

More information

Chapter 24: Residential Overhead Door Openings

Chapter 24: Residential Overhead Door Openings Chapter 24: Residential Overhead Door Openings Most Common Mistakes: 1. Column(s) next to door turned wrong direction. 2. Header placed at incorrect height. 3. Wall not square prior to framing opening.

More information

Installation Instructions: Urbanline Euro Selekta Clad

Installation Instructions: Urbanline Euro Selekta Clad Product description Ecology Technical data Urbanline Euro Selekta Clad (selekta façade profiles and heritageselekta façade profiles) are identical in terms of their core material and surface texture. However,

More information

THE PLACEMENT OF ALUMINIUM PROFILES IN THE FRAME VIEW FROM THE FRONT SIDE 2

THE PLACEMENT OF ALUMINIUM PROFILES IN THE FRAME VIEW FROM THE FRONT SIDE 2 1 Contents THE PLACEMENT OF ALUMINIUM S IN THE FRAME VIEW FROM THE FRONT SIDE 2 THE PLACEMENT OF ALUMINIUM S IN THE SERVICE DOOR VIEW FROM THE FRONT SIDE.. 3 LIST OF ALUMINIUM S FOR SERVICE DOOR... 4 ASSEMBLY

More information

Installation Manual In-Roof Reflector-System Inflecs Pro

Installation Manual In-Roof Reflector-System Inflecs Pro Installation Manual In-Roof Reflector-System Inflecs Pro AkoTec Produktionsgesellschaft mbh * Grundmühlenweg 3 * 16278 Angermünde Tel: 03331-29 66 88 * Fax: 03331-25 59 996 * Email: info@akotec.eu * www.akotec.eu

More information

How To Install Windows: Nail-Fin Application

How To Install Windows: Nail-Fin Application How To Install Windows: Nail-Fin Application Required Tools & Materials: Materials: 1 3/4" galvanized roofing nails. Nails must penetrate at least 1" into framing For mulled and/or DP50 or above units:

More information

The Leka System Installation Guide

The Leka System Installation Guide Installation Guide The Leka System Installation Guide The following guide has been created to assist in the fabrication and installation of the Leka System. Please note that each roof is individual and

More information

Pipe penetration refer CT15. Viking CertainTeed Shingles General Roof details

Pipe penetration refer CT15. Viking CertainTeed Shingles General Roof details Vented ridge refer CT02 Substrate Viking SuperStrand or F11 Roofing ply Pipe penetration refer CT15 Valley details refer CT07 and CT08 refer CT17 and CT18 for requirements Drip-edge refer CT01 Barge detail

More information

SUPREME WALL GARDEN ASSEMBLY INSTRUCTIONS 24/08/16 www.hallsgreenhouses.com Please refer to website for the most up to date instructions. SAFETY WARNING 1. Always wear protective glasses, shoes, gloves

More information

equinox INSTALLATION GUIDE Issue CONTENTS If in doubt at any stage BE SAFE WHEN WORKING AT HEIGHT

equinox INSTALLATION GUIDE Issue CONTENTS If in doubt at any stage BE SAFE WHEN WORKING AT HEIGHT equinox INSTALLATION GUIDE Issue 3 CONTENTS 1. Preparing the ring beam 2 2. Installing the eaves beam 3 3. How to install structural support posts 7 4. Insulating and waterproofing 8 5. Tile application:

More information

Installation Instructions

Installation Instructions Installation Instructions Alpha SolarSmart On Roof Kits for the Installation of Alpha Solar Collectors onto Tile and Slate Type Roofs For Technical help or for Service call... ALPHA HELPLINE Tel: 0 77

More information

SECTION SHEET METAL FLASHING AND TRIM

SECTION SHEET METAL FLASHING AND TRIM SECTION 07620 SHEET METAL FLASHING AND TRIM PART 1 GENERAL 1.1 SUMMARY A. Section includes flashings and counterflashings, sheet metal roofing and fabricated sheet metal items, as indicated in Schedule.

More information

Recommended Slating Tools

Recommended Slating Tools Recommended Slating Tools Product Size L Sketch of Article No. Description 60-070 Scriber 60-00 Slater s Hammer 60-00 Slater Ripper 60-080 Parallel Shears 60-0 Slate Cutter Kwiksnip Slate Guuillotine Slate

More information

CERACLAD.

CERACLAD. CERACLAD 4. Horizontal Application (Wood Structure) Instructions and Details Siding Panel Installation Accessories Installation Overview Starter Bar Installation Install s Installation

More information

Handleless Uni t Specification

Handleless Uni t Specification Handleless Uni t Specification QUALITY BRITISH CRAFTSMANSHIP 160 Handless Fitting Guide - Parts Index & Base Cabinet Section 1 150 325 DRAWER 870 870 870 73 73 720 720 DOOR 685 325 2 x

More information

Assembly instructions. NL2320 Deco outdoor sauna

Assembly instructions. NL2320 Deco outdoor sauna Assembly instructions NL2320 Deco outdoor sauna Saunastore 8.11.2014 Aluminium base frame is placed on the floor. Fasten the corners together with screws (4x30 mm). Crossmeasure from the corners to check

More information

Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK WA 1 - Ü 150 E

Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK WA 1 - Ü 150 E Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK 150-275 WA 1 - Ü 150 E 1 F Ü R D I E ZU K U N FT G E DAC HT. The alwitra waterproofing system alwitra wall flashing profiles are part of the practically

More information

Guardian warm roof conversion system. Installation Guide

Guardian warm roof conversion system. Installation Guide Guardian warm roof conversion system Installation Guide 2 www.guardianroof.co.uk Conservatory walls consist largely of glazed elements including windows and doors that may include structural mullions or

More information

Architectural Information Series 614 ClearVENT Double-hung Window Design Features Australian registered design

Architectural Information Series 614 ClearVENT Double-hung Window Design Features   Australian registered design Architectural Information Page: 27. 1 Introduction Design Features This full vision vertical sliding sashless double-hung window has been designed to complement our existing quality product range including:

More information

SuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter

SuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter SuperFOIL Insulation Solutions Guide Pitched Roof - Under Rafter SF19+ Pitched Roof Under Rafter Solutions CONSTRUCTION THICKNESS R -VALUE EXTERNAL SURFACE - 0.040 TILES / SLATES 10mm - BATTEN CAVITY 25mm

More information

Halny Romana by. The roofing pantile with the invisible fastening system. Made from. Steel. Aluminium. Copper. need of special tools

Halny Romana by. The roofing pantile with the invisible fastening system. Made from. Steel. Aluminium. Copper. need of special tools Halny Romana by The roofing pantile with the invisible fastening system 1 Made from Steel Aluminium 2 Copper - ultra lightweight modular panels - easy installation - fixing spots only visible on the outer

More information

WESTERN WAVE Panel. Horizontal Installation and Technical Information

WESTERN WAVE Panel. Horizontal Installation and Technical Information WESTERN WAVE Panel Horizontal Installation and Technical Information Western States Western Wave Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page

More information

Special Roofs and Vertical Slating

Special Roofs and Vertical Slating Special Roofs and Vertical Slating Roofs falling into the category of "special" roofs have the following characteristics: (a) any roof slope equal to or greater than the minimum pitch for the size of slate

More information

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE

COMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE INTRODUCING THE CLICKFAST FASCIA AND GUTTER SYSTEM The Clickfast Fascia and Gutter System was originally designed by Stratco and has proven to be the most successful fascia and gutter system in Australia

More information

Basic Fitting Details No. 1

Basic Fitting Details No. 1 No. 1 Fixing free edges of flashings A. Clips for flashings over interlocking tiles B. Clip to ridge or hip roll C. Clip to apron flashings Clips should be made from quarter hard copper, 0.6mm thick, terne

More information

Architectural Information Page: Series 602 Magnum Sliding Window Introduction. Design Features : Date: Aug 03 Replaces: Scale: Not to scale

Architectural Information Page: Series 602 Magnum Sliding Window Introduction. Design Features : Date: Aug 03 Replaces: Scale: Not to scale Design eatures : Architectural Information Page: 17. 1 Introduction Date: Aug 03 Replaces: Scale: Not to scale This high performance sliding window has been designed to complement our existing high quality

More information

INSTALL IN 2 DAYS. *Assumes 3-man fitting team. equinox. Tiled roof system. Installation guide ISSUE 1

INSTALL IN 2 DAYS. *Assumes 3-man fitting team. equinox. Tiled roof system. Installation guide ISSUE 1 INSTALL IN 2 DAYS *Assumes 3-man fitting team equinox Tiled roof system Installation guide ISSUE 1 Equinox tiled roof system Installation guide Contents Pre-installation checks 1. Installing the framework

More information

Multi-layer Insulation Blanket for

Multi-layer Insulation Blanket for Pitched roof insulation Fully certificated Thermally tested in accordance with EN12667 High thermal resistance of 2.71m²K/W Class 1 Surface spread of flame Ideal for New build & Refurbishment Effective

More information

Contents. Stage 1. Preparation of the aperture 9. Interior finishing 25

Contents. Stage 1. Preparation of the aperture 9. Interior finishing 25 Installation Manual Pitchglaze Roof Window Contents Contents and introduction 2 Delivery 3 Pre Installation 4 Installation 8 Stage 1. Preparation of the aperture 9 Stage 2. Fitting the Pitchglaze 11 Stage

More information

How-To-build guide Garden shed

How-To-build guide Garden shed How-To-build guide Garden shed What you can build using this guide This guide will show you how to build a re-locatable garden shed. Before you begin building Contact your local territorial authority to

More information

1 Roof Substrate (Deck) OWENS CORNING BERKSHIRE SHINGLES INSTALLATION INSTRUCTIONS

1 Roof Substrate (Deck) OWENS CORNING BERKSHIRE SHINGLES INSTALLATION INSTRUCTIONS General This Installation Instruction document for Owens Corning Berkshire roofing shingles is to be read in conjunction with the Installation information printed on each packet of shingles along with

More information

Components Catalog. Mounting Systems. Version 18.01, updated: 05/25/2018

Components Catalog. Mounting Systems. Version 18.01, updated: 05/25/2018 Components Catalog Mounting Systems Version 18.01, updated: 05/25/2018 1 Index IBC TopFix 200 Components... 5 Roof Tiles... 6 Roof Hook Alu-Vario S+... 6 Roof Hook Alu-Mammut S+... 6 Roof Hook Alu-Mammut

More information

Installation Guide Simplicity Alfresco. V1.9 Lu070318

Installation Guide Simplicity Alfresco. V1.9 Lu070318 0333 305 5272 www.canoports.co.uk Installation Guide Simplicity Alfresco V1.9 Lu070318 Tools Required Below is a list of tools that you will require to install your the Simplicity Alfresco System. Cordless

More information

Vi - BOX GUTTER COMPONENT REFERENCE

Vi - BOX GUTTER COMPONENT REFERENCE Page 114 Vi - BOX GUTTER COMPONENT REFERENCE Item No Item Description Pack Comments BG1 Box Gutter D BG2 Box Gutter Braces A BG4 Box Gutter Sealing Tape A BG7 Box Gutter Internal Cladding D BG8 135 Box

More information

46, 66, Page /01/17

46, 66, Page /01/17 46, 66, 86 46 Only Instructions Page 29-31 www.hallsgreenhouses.com Please refer to website for the most up to date instructions. 05/01/17 333 1106 No. 6 x 16mm Long 711 F B D E C A G I,H J K L M

More information

Inspire Slate Starter Piece Hip and Ridge. 13 1/2" Height: 13 ½" Width: 12" Squares/ Pallet. Bundles/ Square

Inspire Slate Starter Piece Hip and Ridge. 13 1/2 Height: 13 ½ Width: 12 Squares/ Pallet. Bundles/ Square December 2017 Classic Slate Application Guidelines Only Basic Roofing Tools Required Hand fastened or fastened with a pneumatic nail gun Utility knife or a standard circular saw Tape measure, pry bar,

More information

METAL STRAPPING. .018" (.5mm) EDGE BAND 9 16 " GYPSUM BOARD PSI PANEL RIGHT SIDE VIEW #312 HORIZONTAL REVEAL / DIVIDER

METAL STRAPPING. .018 (.5mm) EDGE BAND 9 16  GYPSUM BOARD PSI PANEL RIGHT SIDE VIEW #312 HORIZONTAL REVEAL / DIVIDER MIDWALL PANEL JOINTS 01.018" (.5mm) EDGE BAND #312 HORIZONTAL REVEAL / DIVIDER RIGHT SIDE VIEW MIDWALL PANEL JOINTS 01.018" (.5mm) EDGE BAND #312RI INSERT #312 HORIZONTAL REVEAL / DIVIDER RIGHT SIDE VIEW

More information

PV SLATE ROOF INSTALLATION GUIDE

PV SLATE ROOF INSTALLATION GUIDE The PV Slate roof tile is designed to integrate into a roof clad with either natural or imitation slates. Initial Roof Batten Layout. The roof should be battened using 50x25mm batten at a spacing of 270mm.

More information

OWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS

OWENS CORNING LAMINATE SHINGLES INSTALLATION INSTRUCTIONS General This Installation Instruction document for Owens Corning asphalt roofing shingles is to be read in conjunction with the Installation information printed on each packet of shingles along with the

More information

CFDTT-01. Control Joint Study (General)

CFDTT-01. Control Joint Study (General) Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area

More information

Window with Nail fin (New construction)

Window with Nail fin (New construction) Window with Nail fin (New construction) Disclaimer: Improper installation and care may void warranty. These instructions are a basic/general recommendation for installation, but may not be utilized in

More information

Contents. Basics of ventilated facades Service package. Brackets. Project-Checklist Reference projects

Contents. Basics of ventilated facades Service package. Brackets. Project-Checklist Reference projects A structured approach to facades Contents Basics of ventilated facades... 3 Building physics Service package Static analysis... 4 Installation training... 4 Installation plans... 5 Brackets MacFOX... 6

More information

SIMPLER BETTER FASTER

SIMPLER BETTER FASTER SIMPLER BETTER FASTER 1. FITTING RING BEAMS DETAILS Always work anti-clockwise viewed from outside the roof. Each bar should be sequentially numbered, i.e. 1, 2, 3. Select the ring beam, position the left

More information

900 SERIES WALL PANELS

900 SERIES WALL PANELS CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900

More information

ARCHITECTURAL STYLE: ENGLISH TUDOR COTTAGE

ARCHITECTURAL STYLE: ENGLISH TUDOR COTTAGE ARCHITECTURAL STYLE: ENGLISH TUDOR COTTAGE English Cottage style homes are smaller in size and typically one to two stories. It is often referred to as Storybook style. The asymmetrical homes tend to be

More information

ASSEMBLY INSTRUCTIONS RUUKKI HYYGGE

ASSEMBLY INSTRUCTIONS RUUKKI HYYGGE www.ruukkidachy.pl ASSEMBLY INSTRUCTIONS RUUKKI HYYGGE ASSEMBLY INSTRUCTIONS Ruukki Hyygge Ruukki Hyygge modular steel roof tile is an innovative roofing product that fits perfectly into modern architectural

More information

1 IMPORTING GDL-OBJECT...1

1 IMPORTING GDL-OBJECT...1 GDL-OBJECT TABLE OF CONTENTS 1 IMPORTING GDL-OBJECT...1 2 MTH CONCERTTO -OBJECT...3 2.1. Information-window...3 2.2. Settings-window...3 2.3. Dimensions-window...4 2.4. Mounting frame and screws -window...6

More information

Profile and design dependent - refer to our technical team length width

Profile and design dependent - refer to our technical team length width Smarttray Roofing Systems Roofing Systems Smart tray 510 standing seam custom panel introduction Due to the nature of the materials used we are able to accomodate most non standard roof designs The design

More information

Multi-layer Insulation Blanket for

Multi-layer Insulation Blanket for Data Sheet for Fitting Superquilt Under or over Rafters to Roofs To Order Superquilt direct at Lowest prices in the UK or Europe UK Customers Call 0844 9919949 From outside the UK Call 0044 1143230474

More information

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION 1. Scope 4. Underlayment 2. 1.1 This roofing application standard has been developed to provide a responsive

More information

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION

ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION ROOFING APPLICATION STANDARD (RAS) No. 115 STANDARD PROCEDURES FOR ASPHALTIC SHINGLE INSTALLATION 1. Scope 4. Underlayment 2. 1.1 This roofing application standard has been developed to provide a responsive

More information

Sutton Screened in Awning / Porch

Sutton Screened in Awning / Porch Sutton Screened in Awning / Porch Sections: Project Overview Roof Work Cedar Framing Canopy Frame Screen Frames Misc. Sheet 1 - - - Index Sheet 2 - - - Project Summary Sheet 3 - - - Roof Work overview

More information

GRANDIO G R E E N H O U S E S. Model GRA-812BR-GR. 8x12 GRANDIO ELITE GREENHOUSE USER MANUAL

GRANDIO G R E E N H O U S E S. Model GRA-812BR-GR. 8x12 GRANDIO ELITE GREENHOUSE USER MANUAL GRANDIO G R E E N H O U S E S Model GRA-8BR-GR 8x GRANDIO ELITE GREENHOUSE USER MANUAL 03 Grandio Greenhouses, Backyard Living Source Inc. All rights reserved GRANDIO G R E E N H O U S E S IMPORTANT! PLEASE

More information

182.1 INTRODUCTION SERIES 462 ARCHITECTURAL COMMERCIAL SLIDING WINDOW. Design Features : Australian Registered Design.

182.1 INTRODUCTION SERIES 462 ARCHITECTURAL COMMERCIAL SLIDING WINDOW. Design Features : Australian Registered Design. INTRODUCTION DATE JUN 06 REPLACES NOV 04 SCALE NOT TO SCALE Design Features : The 26mm thick heavy duty sliding window sashes have been fitted into custom head and sill and jamb inlay adaptor that snaps

More information

Unit 9. Wall and Ceiling Framing

Unit 9. Wall and Ceiling Framing Unit 9 Wall and Ceiling Framing Wall construction Wall framing includes the assembly of horizontal and vertical members that make up exterior walls and interior partitions. Theses walls support the ceilings

More information

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.

Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation. Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed

More information

GRANDIO G R E E N H O U S E S GRANDIO ASCENT ADDITIONAL ROOF VENT KIT FOR NEW AND EXISTING GREENHOUSE CUSTOMERS

GRANDIO G R E E N H O U S E S GRANDIO ASCENT ADDITIONAL ROOF VENT KIT FOR NEW AND EXISTING GREENHOUSE CUSTOMERS GRANDIO G R E E N H O U S E S GRANDIO ASCENT ADDITIONAL ROOF VENT KIT FOR NEW AND EXISTING GREENHOUSE CUSTOMERS (GRA-ASC-VENT) ASCENT ROOF VENT PACKING LIST GRAPHIC PART NAME SIZE/LOCATION QUANTITY GRAPHIC

More information

60.AL. Lauder. Facade LAUDESCHER

60.AL. Lauder. Facade LAUDESCHER 60.AL Facade Lauder LAUDESCHER General performance Industrial manufacturing process Rebated using halved joint assembly guaranteeing perfect hold of the linear panel. Solid wood All of our solid wood is

More information

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE

More information