Installation Instructions: Urbanline Euro Selekta Clad
|
|
- Moris Robinson
- 5 years ago
- Views:
Transcription
1 Product description Ecology Technical data Urbanline Euro Selekta Clad (selekta façade profiles and heritageselekta façade profiles) are identical in terms of their core material and surface texture. However, they are available with different surface coatings. The particle wood core consists of processed timber. We use exclusively untreated pulpwood in the form of wood shavings, thinning material and round timber from sustainable, domestic forestry. Imported timber is not used - especially from tropical climates. The binding agent used is a thermosetting artificial resin with building authority approval for outdoor use. s a wood preservative, we use an eco-friendly boron-based product with building authority approval that does not contain lindane or PCP. For the low flammability version, a mixture of boric acid and borax is used as a fire protection agent. No isocyanates, phosphates or halogens are added. Several layers of paper are impregnated with artificial resins for use as a coating. The surface and core are fused together without seams in a single process under the application of pressure and heat. Colorpan Base coating of paper impregnated with melamine resin, followed by coloured Colorpan surface coating using a pure, water-based acrylate. The pigments added are free of toxic heavy metals (no lead, chrome or cadmium). Dekopan Plus Multi-layer coating, printed or dyed; transparent, weatherresistant surface coating of the decor side. Rear side brown, no colour options. Technical data Values Unit Test specification. Density kg/m EN. Flexural strength 0 N/mm EN 0. Elasticity modulus N/mm EN 0. Tensile strength vertical to the surface.0.0 N/mm EN 9. Screw withdrawal strength ) N WERZLIT TEST STNDRD. Swelling after storage after h % EN in water at 0 C after h.0.0 % EN. Moisture content 0 % EN 8. Temperature resistance under permanent load under temporary load 9. Fire behavior, class Standard version: B = normal flammability, special version B: low flammability Length change due to moisture/heat exposure ) -0 to C C WERZLIT TEST STNDRD B and B ) DIN 0 mm/m WERZLIT TEST STNDRD. Thermal conductivity λ W/m K DIN. Water vapour permeability diffusion-equivalent air layer thickness m DIN. Cross-cut test ) GT 0 GT EN ISO 09. Scratch resistance 0.. N EN 8. Light fastness Level 8 DIN 00. Chemical resistance limited resistance EN 8. Cigarette burn resistance not resistant to burns as for EN 8 8. Colour deviation ) Δ E < DIN 0 9. Impact load impact resistant WERZLIT TEST STNDRD ) mm particle board screw, using a hole of mm diameter, 0 mm deep. ) Not available for all products, please ask for specific information. ) Maximum expected length change under extreme climate fluctuations. ) Gt 0 is the best, Gt is the worst value. ) With measurement geometry 0 /, standard illuminant C. v.ul..9. Phone sales@urbanline.com.au
2 General information, Profile dimensions, Calculating the required quantity & Guidelines 0 0 Coverage widths + - Scope The scope of these installation instructions covers all installation variants of façade cladding, including soffits. 9 8 Calculating the required quantity (Calculation values exclude cutting waste) Required quantity/m Required quantity/m Coverage width Standard lengths Façade profile Façade screw. x 0, stainless steel Urbanline Euro Selekta Clad (Colorpan/Dekopan plus) at max. fastening spacing = mm (heritage-selekta) mm 00 mm. linear m 0. pcs. (selekta) mm 00 mm. linear m 0. pcs. Note! Top view The DIN requirements are presented here in The wood decors are equivalent to natural wood surfaces, meaning that different grain textures are possible within a single shipment (plain and/or mottled). Unfortunately, sorting at the factory is not possible! In order to obtain a uniform overall finish, we recommend considering this fact and, for example, laying out the façade profiles before starting with the installation. Wind side e d a simplified form as a general rule of thumb. Precise information on this topic must be taken from DIN 0, Part from March 00. The building dimensions are naturally Installation lengths View (cladding side) of primary importance for determining the size of area with increased For installation lengths of more than 00 mm, the profiles must wind suction (exterior be cut to a maximum length of 00 mm in order to minimise the expansion joints. Wind side B pressure coefficients). Sub-framework for façade cladding e/ d-e/ ccording to DIN 0, Part, the increased wind suction at the edge areas of the building walls must be considered when planning the sub-framework. The fastening spacing of the Urbanline Euro Selekta Clad (WERZLIT façade) profiles must be reduced to max. 00 mm in these areas; additional support battens must be provided as necessary. d Example: Wind side Cladding side rea with increased suction Batten spacing in area Normal area Batten spacing in area B e = m d = 8 m = e/ = m max. 00 mm B = d-e/ = m max. mm If two opposite main wind directions exist (e.g. west/east), area must naturally also be observed on the other side of the cladding wall. In the above example, area B would then only be m wide. Fire Protection see attached Fire Test Report v.ul..9. Phone sales@urbanline.com.au
3 Horizontal installation Sub-framework max.. Urbanline Euro Selekta Clad (UESC (Selekta / heritage-selekta façade profile). Façade screw. x 0, stainless steel. Support batten 0 mm x 0 mm, spacing max. mm. Fastening with screws x 0, stainless steel. Counter batten at least 0 mm x 0 mm. Dowel and screw with building authority approval. Insulation in two layers, pressure-resistant B - C Sections. UESC selekta / heritage-selekta façade profile. Back ventilation spacing at least 0 mm *) *) For selekta façade profiles in version B (low flammability) at least 0 mm Important Building Design Notes: Sub-framework The supporting wall must be watertight and correct flashings used in the event of any water penetration i.e. severe storms There must be ventilation/ drainage at the base of the wall Install breathable sarking over the stud frame keeping all overlaps pointing downwards 0 mm and tape all joints Composite products expand B Horizontal section C Vertical section and contract with temperature longitudinally see installation instructions for joint options. v.ul..9. Phone sales@urbanline.com.au
4 Horizontal installation X Fastening spacing. UESC (selekta / heritage-selekta façade) profile max. 00 X. Façade screw. x 0, stainless steel. Punched holes. Support batten 0 mm x 0 mm X = or more supports, max. mm max. 00 X X = for only supports, max. 00 mm; Profile excess length max. 00 mm Fastening materials Fastening spacing B Sub-framework, alternative Use only screws. x 0, stainless steel. lways centre the screws in the punched fastening holes of the façade profile. B Sub-framework alternative 0 e. g. aluminium and wood sub-frameworks. Building wall. Thermal insulation. Support batten max U bracket lternatively, other sub-framework systems C Start of installation, alternative D Internal corner can also be used, such as for very thick insulation layers. C Start of installation from below. selekta / heritage-selekta façade profile. Starting profile T + G, aluminium. Starting profile P, aluminium (alternative) We recommend a max. 0 mm projection of the starting profile P. Ventilation profile, plastic D Internal corner. selekta / heritage-selekta façade profile. Jointing tape, plastic or suitable construction adhesive. luminium internal corner profile (lternative). Ventilation opening, continuous Please note: Baseboard termination t least 00 mm spacing to the floor. void designs that allow moisture build-up. v.ul..9. Phone sales@urbanline.com.au
5 Horizontal installation External corner. UESC (selekta / heritage-selekta façade profile). External corner C, aluminium (two-part). luminium external/internal corner profile (lternative). Cylinder sheet screw.9x, stainless steel The external corner C consists of lower profile and cover profile. The cover profile is clipped on after installation of the façade External Corner C Side Termination profile and secured to each profile bar in the upper area using cylinder sheet screws, pre-drilled to ø. mm. Please note: The luminium External/ Internal corner profile can be used in reverse for Internal corner applications at least 0mm B Side termination. UESC (selekta / heritage-selekta façade profile). Cover angle 0/0, aluminium D Connection to pitched roof. Sealing material. Connection profile F, aluminium C Roof connection. UESC (selekta / heritage-selekta façade profile). Edge trim profile, aluminium (alternative spacer bar, 9 mm). Ventilation profile, plastic. Ventilation opening, continuous. Roof tile v.ul..9. Phone sales@urbanline.com.au
6 Horizontal installation - B - C Window lintel connection. selekta / heritage-selekta façade profile Connection profile F, aluminium Z profile, aluminium External corner profile, plastic (Cut off lower leg) Ventilation profile, plastic Cladding panel (alternative) 8 0 Edge trim profile, aluminium 8 Ventilation opening, continuous Window lintel connection t the transition between the reveal and the lintel, the connection profiles F are given a mitre cut. 0 B The Z profile, aluminium, covers the vertical connection profile F. 0 C Window sill connection. selekta / heritage-selekta façade profile Ventilation profile, plastic Z profile, aluminium Outer window sill Ventilation opening, continuous 0 8 B Window lintel connection, alternative D Window reveal connection D Window reveal connection. selekta / heritage-selekta façade profile. Connection profile F, aluminium. Sealing material. luminium external corner profile. Outer window sill 0 mm approx. 0 mm C Window sill connection v.ul..9. Phone sales@urbanline.com.au
7 Horizontal Installation only for (selekta) UESC Profile butt joints The profiles can be installed in staggered arrangement or with a continuous vertical joint. Staggered arrangement. selekta façade profiles, cutting length. Install support battens in each joint area max. 00 mm Staggered arrangement max. D X Notching of the groove lip. Jointing tape, plastic Profile butt joint with butt connector max. 00 mm max. 00 mm When installing in a staggered arrangement, the expansion joints can be closed with butt connectors. Notch the groove lip on the back side of the façade profile. See images C to D B - C - D Butt connector / (for selekta façade profile ) Place the butt connector / on the lower façade profile and nail it to the support batten. Slide the notched façade profiles from both sides onto the butt connector, expansion joint 0 mm. B Butt connector / E Continuous profile butt joint. selekta façade profile. Butt connector /, plastic D Notching of the groove lip X = mm, for butt connector / 0 E - F Continuous vertical profile butt joint C Profile butt joint without butt connector F Cover profile T + G. selekta façade profile. Support batten, width at least 00 mm. Jointing tape, plastic. Cover profile T + G, aluminium. Pan head screw x 0, stainless steel Tip: Peg a mm wide batten to the sub-framework at the joint location. Position the façade profiles flush on both sides. fter installation of the façade profiles, remove the batten and screw on the cover profile T + G in its place. v.ul..9. Phone sales@urbanline.com.au
8 Horizontal installation only for (heritage-selekta) UESC Profile butt joints The profiles are installed in a staggered arrangement. There is no need to ensure an orderly joint arrangement. No battens are required under the joints. Staggered arrangement. heritage-selekta façade profile. No support batten is required in the joint area. Minimum length of the first profile: mm Staggered arrangement 8 v.ul..9. Phone sales@urbanline.com.au
9 max. Installation Instructions: Urbanline Euro Selekta Clad Vertical installation only for UESC (selekta) 00 - Sub-framework. selekta façade profile. Façade screw. x 0, stainless steel. Support batten 0 mm x 0 mm, spacing max. mm. Fastening with screws x 0, stainless steel. Counter batten at least 0 mm x 80 mm, or at least 0 mm higher than second layer of thermal insulation. (See also note for B C, no. ). Dowel and screw with building authority approval. Insulation in two layers, pressure-resistant B - C Sections. selekta façade profile. Back ventilation spacing at least 0 mm*) *) For selekta façade profiles in version B (low flammability) at least 0 mm. Sub-framework 0 mm B Horizontal section C Vertical section 9 v.ul..9. Phone sales@urbanline.com.au
10 Vertical installation only for UESC (selekta) max. 00 max. 00 Fastening spacing. UESC (selekta façade profile) X X. Façade screw. x 0, stainless steel. Punched holes. Support batten 0 mm x 0 mm X = or more supports, max. mm X X = For only supports, max. 00 mm; profile excess length max. 00 mm Fastening materials Fastening spacing B Sub-framework, alternative Use only screws. x 0, stainless steel. lways centre the screws in the punched fastening holes of the façade profile. B Sub-frameworks alternatives at mind. least 0 mm. Building wall. Thermal insulation, two layers. Counter batten. U bracket C Start of installation D Connection to pitched roof. Support batten 0 mm x 0 mm lternatively, other sub-framework systems can also be used, such as for very thick insulation layers. D Connection to pitched roof. selekta façade profile C Start of installation from below. selekta façade profile. Layering profile, aluminium. Ventilation profile, plastic. Ventilation opening, continuous. Ventilation profile, plastic. Ventilation opening, continuous. Roof tile E Internal corner. selekta façade profile E Internal corner, alternative 0 Please note: Baseboard termination at least 00 mm spacing to the floor. void designs that allow moisture build-up.. Spacer bar, 9 mm. luminium internal corner profile. Jointing tape, plastic or suitable construction adhesive v.ul Phone sales@urbanline.com.au
11 Vertical installation only for UESC (selekta) External corner. selekta façade profile. Spacer bar, 9 mm. External corner C (two-part), aluminium. luminium external/internal corner profile. Cylinder sheet screw.9 x, stainless steel The external corner C consists of lower profile and cover profile. The cover profile is clipped on after installation of the façade profile and secured to each profile bar in the upper area using cylinder sheet screws, pre-drilled to ø. mm Please note: The luminium External/Internal corner profile can be used in reverse for Internal corner applications External corner, alternative B Connection to side in niche. selekta façade profile. Spacer bar, mm. Cover angle 0/0, aluminium. Sealing material, e. g. Compriband 0 B Connection to side in niche v.ul..9. Phone sales@urbanline.com.au
12 Vertical installation only for UESC(selekta) - B - C Window lintel connection. selekta façade profile. Connection profile F, aluminium. Z profile, aluminium. External corner profile, plastic (cut off lower leg). Ventilation profile, plastic 0. Edge trim profile, aluminium Spacer bar, 9 mm (alternative to ). Ventilation opening, continuous Window lintel connection t the transition between the reveal and the lintel, the connection profiles F are given a mitre cut. 0 B The Z profile, aluminium, covers the vertical connection profile F. 0 C Window sill connection. selekta façade profile. Ventilation profile, plastic. Outer window sill. Z profile, aluminium. Ventilation opening, continuous B Window lintel connection, alternative D Window reveal connection D Window reveal connection. selekta façade profile. Connection profile F, aluminium. Spacer bar 9 mm. luminium external corner profile, alternative external corner C, aluminium. Sealing material, e. g. Compriband. Edge trim profile, aluminium C Window sill connection 0 mm approx. 0 mm. Outer window sill v.ul..9. Phone sales@urbanline.com.au
13 Installation Instructions: Urbanline Euro Selekta Clad 0 0 Butt joints and diagonal installation - B Vertical installation, continuous. selekta façade profile Install support battens 0 mm x 0 mm in each joint area Jointing tape, plastic 00 - X = max. Vertical installation B Continuous horizontal butt joint Z profile or, aluminium, maintain a 0 mm expansion joint at top and bottom C - D Vertical / horizontal installation, continuous horizontal butt joint The sub-framework must be modified at C Vertical / horizontal installation D Continuous horizontal butt joint the butt joint according to the installation direction. E Vertical / horizontal installation F Continuous vertical butt joint *) For selekta façade profiles in version B (low flammability) at least G Diagonal 0 mm! installation Note: Position the vertical support battens at the transition point at least mm above the horizontal counter batten to ensure back ventilation*).. selekta façade profile Support battens 0 mm x 0 mm Jointing tape, plastic Z profile or, aluminium, maintain 0 mm gap at top and bottom L Back ventilation spacing at least 0 mm *) E - F Vertical / horizontal installation, continuous vertical butt joint. selekta façade profile. Support batten, width at least 00 mm. Jointing tape, plastic. Cover profile T + G, aluminium. Pan head screw x 0, stainless steel Vertical installation B Continuous horizontal butt joint profiles, remove the batten and screw 9 G Diagonal installation, X = max. a Tip: Peg a mm wide batten to the sub-framework at the joint location. L Position the façade profiles flush on both sides. fter installation of the façade 8 depending on thermal insulation + 0 mm for back ventilation spacing 0 0 Vertical installation B Continuous horizontal butt joint C Vertical / horizontal installation D Continuous horizontal butt joint X = max. max. E Vertical / horizontal installation F Continuou E Vertical / horizontal installation F Continuous vertical butt joint G Diagonal installation G Diagonal installation on the cover profile T + G in its place. G Diagonal installation sub-framework. selekta façade profile. Counter batten, cross-section (see also note for C D, no. ). pproved dowel incl. stainless steel screw. Support batten 0 mm x 0 mm. Fastening with screws x 0, stainless steel. Façade screw. x 0, stainless steel. Layering profile, aluminium, see also page 8 8. Façade profile end pieces, fasten with at least screws 9. Install corresponding battens Vertical installation B Continuou Vertical installation B Continuous horizontal butt joint X = max. max. a C Vertical / horizontal installation D Continuou L 00 - C Vertical / horizontal installation D Continuous horizontal butt joint L Support batten spacing = BS Fastening spacing = X (measure parallel to the façade profile) The spacing of the support battens BS depends on the selected installation angle α and the fastening spacing X X = or more supports, max. mm X = For only supports, max. 00 mm Examples: 00 - E Vertical / horizontal installation F Continuous vertical butt joint X = max. X = max X = max. Installation angle α 0 max. mm max. mm BS = or more supports 0 0 BS = For only supports 0 0 a v.ul X = max. Phone sales@urbanline.com.au
14 Soffits - B Soffit, installed lengthwise. Universal angle selekta / heritage-selekta façade profile Spacer bar 9 mm Ventilation profile 0 lternative edge trim profile Roof tile 0 C Soffit, installed crosswise Verge section, soffit installed lengthwise B Wall connection, alternative. Cover angle 0/0, aluminium 8. Sealing material 9. Ventilation opening, continuous 0. Starting profile P 9 at least C Verge section, soffit installed crosswise v.ul..9. Phone sales@urbanline.com.au
15 General guidelines rguments for a back-ventilated curtain cladding of the exterior wall Energy savings Weather protection ttractive design Increased building value Handling The selekta façade profiles must be stored in their packaging, lying flat and dry until use. Sawing with power tools Hard metal saw blade, high number of teeth, (tooth pitch approx. 0 mm), saw blade with alternate top bevel or hollow-tooth flat-top teeth. Sawing with hand saws well-sharpened and dressed saw with small teeth is sufficient. Fastening the façade profiles Only with WERZLIT façade screws. x 0, stain- less steel. Centre the fastening screws through the existing punched holes. The screws may only be screwed in until the screw head rests against the surface. Fastening of all connection profiles Only with WERZLIT façade screws. x 0, stainless steel. Please note: Heavy structures, such as an awning, climbing trellis, etc., may not be fastened directly to the cladding or its sub-framework. Provide separate sub-frameworks. Sub-framework Façade profiles are typically fastened to a wood sub-framework. In principle, the following guidelines should be followed for wood sub-frameworks: a) The wood must correspond to grade S0 (or MS0) according to DIN 0. b) The individual cross-section must be selected according to DIN 0, Part. c) The wood must be protected according to DIN 8800, wood preservation. d) The sub-framework must be fastened using dowels and screws with building authority approval and in accordance with the instructions of the manufacturer. e) The support battens must be fastened to the counter battens with at least wood screws, stainless steel, per intersection, in a diagonal arrangement. f) The sub-framework must be level and plumb. Dimensional tolerances can be found in DIN 80 Part and Part. g) ll Structural framework must be in accordance to ustralian Building Standards & Local Building Codes. Thermal insulation The thermal insulation must be dimensioned according to the current German energy conservation regulations (EnEV). The thermal insulation material must be fastened with appropriate hardware, such as insulation pins, in accordance with the instructions of the manufacturer. The installation must be made windproof to prevent cold air from flowing behind it. We therefore recommend installing in two layers with overlapping joints. The insulation must be flush against the wall. Back ventilation The back ventilation spacing must be at least 0 mm *). Expansion The length change of the façade profiles is approx. mm/linear m, depending on moisture and temperature. Expansion joints of 0 mm must be maintained at profile butt joints and profile connections. Sealing cut edges Cut edges must be sealed free of pores with Werzalit edge sealant. Exception: Sufficiently covered cut edges under the roof overhang. *) For selekta façade profiles in version B (low flammability) at least 0 mm. The back ventilation cross-section may not be regularly diminished by battens or other objects. The ventilation inlets and outlets must have consistent widths of at least 0 mm. If you have additional questions, please contact Urbanline rchitectural Subject to changes due to technical improvements. v.ul..9. Phone sales@urbanline.com.au
Installation Instructions: Urbanline Alu Selekta Clad
Product description Ecology Technical data Urbanline Alu Selekta Clad (selekta façade profiles and heritageselekta façade profiles) are identical in terms of their core material and surface texture. However,
More informationKEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM
S Y S T E M D E T A I L S FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM PAGE TITLE PAGE Table of Contents Fundermax Max Exterior Product Information Design and Installation Information
More informationKEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR CONCEALED FASTENERS PRESSURE EQUALIZED WALL SYSTEM
S Y S T E M D E T A I L S FUNDERMAX- MAX EXTERIOR CONCEALED FASTENERS PRESSURE EQUALIZED WALL SYSTEM PAGE TITLE PAGE Table of Contents Fundermax Max Exterior Product Information Design and Installation
More informationInstallation instructions: Elements Vulcan+ Newport Hector Cladding
Technical Data Wood Species Thermally Modified Softwood (Pinus Radiata) Images Profile Newport Hector - Light Band Sawn face - Secret fix 5.4 6.0 8.5 3.0 25.0 3.0 111.0 3.0 12.0 R 3.0 7.0 7.0 123.0 15.0
More informationSHIPLOCK CLADDING PRODUCT GUIDE INSTALLATION TECHNICAL SPECIFICATIONS CARE & MAINTENANCE
SHIPLOCK CLADDING PRODUCT GUIDE INSTALLATION TECHNICAL SPECIFICATIONS CARE & MAINTENANCE SHIPLOCK CLADDING CN-04E / CN-04W / CN-W008 Prior to the installation of any form of Cladding, it is recommended
More informationInstallation Instructions
Installation Instructions Roof edge trim profile Series TAG multi-piece aluminium profile Front face height: 250-1050 mm supplied with patented 4F brackets as standard height-adjustable, horizontally moveable,
More informationCembrit Patina. Cembrit Cover. Cembrit Solid. Cembrit Transparent
Rainscreen Cladding Your choice. In addition to the range of colours and shades, Cembrit cladding boards are available in four compositions, each with distinctive performance and characteristics. Cembrit
More informationFold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE
Fold-A-Way Patio Door ASSEMBLY & INSTALLATION GUIDE This instruction guide provides the minimum recommended procedures to correctly prepare the rough opening, install a fold-a-way patio door unit and apply
More informationINSTALLATION INSTRUCTIONS
www.falconpp.co.uk FACADE SYSTEMS INSTALLATION INSTRUCTIONS CONTENTS Contents Benefits page 3 Basics page 4 Installation tips page 5 Colour Glaze (FVG) and Sealing (RFS) page 6 Product range page 7 FACADE
More informationLUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February
LUX Panel V Groove Installation Installation Guide February 2017 www.luxpanel.ca LUX Panel V Groove Installation LUX panel steel cladding is designed to be installed vertically, horizontally, diagonally
More informationHow-To-build guide Garden shed
How-To-build guide Garden shed What you can build using this guide This guide will show you how to build a re-locatable garden shed. Before you begin building Contact your local territorial authority to
More informationtechnical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit
Roofline Installation Details This is intended to provide you with a brief overview of the popular products in Kestrel s Roofline range, where they can be used and the main criteria for installation. Typical
More informationInstallation instructions for co-extruded louver-board profiles
Installation instructions for co-extruded louver-board profiles www.silvadec.com / info@silvadec.com / tel.:+33 (0)2.97.45.09.00 TO BE READ CAREFULLY BEFORE INSTALLATION Before starting installation on
More information15 YEARS GUARANTEE no swelling no cracking no splintering no rotting
I N S TA L L AT I O N R E F E R E N C E S R E S Y S TA FA C A D E 15 YEARS GUARANTEE no swelling no cracking no splintering no rotting 1 1. Basics 2. Product Range 3. General Information 4. Pre-Treatment
More informationMarch High performance building boards
CI/SfB March 2009 (4-) Rf9 High performance building boards High performance building boards Contents 3 Product Selector 4-5 Bluclad 6-7 Hydropanel 8-9 Eterboard 10-11 Duripanel 12 Handling & Storage 2
More informationInstallation Instructions
Installation Instructions Alcove Enclosure Before Installation please check that your shower enclosure system is undamaged Please read these instructions carefully March 2015 TOOLS REQUIRED Electric or
More informationInstallation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes
Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes General Guidelines These instructions show one type of installation and are intended for the professional
More informationAluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement
Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement 1 Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement The following instructions are a supplement
More informationtechnical bulletin Roofline Installation Details No.7 Fascia Installation Details Typical Eaves Details K16 Fascia & 9mm Vented Soffit
Roofline Installation Details This is intended to provide you with a brief overview of the popular products in Kestrel s Roofline range, where they can be used and the main criteria for installation. Typical
More informationREDLAND DRY VALLEY. Installation Instructions for Redland Dry Valley. Version: 6. Date: May Redland Technical Solutions
REDLAND DRY VALLEY Installation Instructions for Redland Dry Valley Version: 6 Date: May 2013 Author: Department: Redland Technical Solutions Redland Technical Solutions 1 Introduction 1.1 TECHNICAL DATA
More informationWave Profile Installation Guide
Wave Profile Installation Guide American Pa o Covers Plus Proudly Builds With Tools & Hardware Wave Profile Installation Guide Tape Measure Square Level Felt tipped Marker and/or grease pencil 3/8" Nut
More informationInstallation Instructions Palladium Square Edge Panels
Please read all instructions before installing wall panels Important 1. Before installation: a. Acclimate Palladium Panels, Trim, adhesives and wall substrates to room temperature 24 hours before installation.
More informationNewTech - CleverDeck Composite Decking Installation Guidelines
NewTech - CleverDeck Composite Decking Installation Guidelines Composite decking has unique characteristics and requires specific fixing requirements that differ from timber. We strongly recommend that
More informationA. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and type.
SECTION 062000 - FINISH CARPENTRY PART 1 - GENERAL 1.1 SECTION REQUIREMENTS A. All trim that has been damages, broken, or missing shall be repaired or replaced with material of the same size, shape, and
More informationNATURA PRO Product Information Leaflet 1
NATURA PRO Product Information Leaflet 1 1. Product composition NATURA PRO sheets consist of the following: Portland cement Mineral fillers Organic reinforcing fibers Additives Semi-transparent water-based
More information40mm Thermoclick. Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial)
http://www.sundancesupply.com 40mm Thermoclick Type II Class 1 Clear Satin Anodize - 201R1 (Mid Grade Commercial) U-Profile 12' Lengths $39 Out System offers a complete set of extrusions and accessories
More informationInstallation Instructions
www.marlite.com Effective Date 03/01/2018 ARTIZAN FRP, SYMMETRIX FRP, ENVUE FRP, STANDARD FRP Installation Instructions Statements expressed in this technical bulletin are recommendations for the application
More informationTOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL
ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL The ProTEC panels are manufactured with grooves on all four sides to accept the steel components. This grooving applies to the regular panel whose
More informationINSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS
www.capecodsiding.com INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS IMPORTANT READ THE FOLLOWING INSTRUCTIONS CAREFULLY BEFORE INSTALLING YOUR WOOD SIDING. FAILURE TO STRICTLY FOLLOW THESE INSTALLATION,
More informationA Shell construction
A Shell construction A 4/2012 Content 1 BASE AND WALL ANCHORING 1.1 Base with mortar bed 1.2 Base with sill plate 1.3 Base with raised sill plate 1.4 Concrete base (mortar bed) 1.5 Concrete base (sill
More informationINSTALLATION GUIDE DECKING.
INSTALLATION GUIDE DECKING www.ttp-online.de/resysta CONTENT LATEST TEST RESULT Classification C, DIN 51097: Features, made by, best skid-resistance properties and is eminently suitable for wet barefoot
More informationCONTENTS. Transitions Board and Batten Vertical Installation... 10,11
INSTALLATION MANUAL CONTENTS Important Notes... 2-4 Weather Protective Barriers... 2 Storage and Transportation... 2 Tools and Equipment... 2 Fastener Choices... 3 Wall Preparation... 3,4 Flashing... 4
More informationEndura-Classic Craftsman Information
Endura-Classic Craftsman Information Endura Classic Craftsman Series Columns have a Limited Lifetime Warranty against rot, corrosion and moisture damage. Endura Classic Craftsman Series Columns are manufactured
More informationDAYLIGHT HARVESTING MULTIWALL. Applications:
DAYLIGHT HARVESTING MULTIWALL Applications: ROOFING FAÇADE INTERIOR OUTDOOR PRODUCT RANGE Tuflite Hollow & Cellular Polycarbonate Sheets: Twin Wall Triple Wall Four Wall Tuflite Multiwall Polycarbonate
More informationDUTCH GABLE FREESTANDING CARPORT
DUTCH GABLE FREESTANDING CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback DUTCH GABLE CARPORT BEFORE YOU START Carefully read these instructions. If
More informationASS 70 FD folding/sliding door installation guide
ASS 70 FD folding/sliding door installation guide 2 Preparation IMPORTANT These doors should be fitted by competent and trained installers. Please read these instructions thoroughly before beginning the
More informationOverlapping panel Cladding system made up of horizontal overlapping panels fixed on a wooden or metal wall-mounted framework.
facade Overlapping panel Cladding system made up of horizontal overlapping panels fixed on a wooden or metal wall-mounted framework. Specification and installation guide Presentation of the system VMZ
More informationASS 70 FD folding / sliding door. Installation Guide
ASS 70 FD folding / sliding door Installation Guide IMPORTANT! These doors should be fitted by competent and trained installers. Please read these instructions thoroughly before beginning the installation.
More informationWall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK WA 1 - Ü 150 E
Wall flashing profiles FP 60 WA 1 WA 150 WA 1 - ÜK 150-275 WA 1 - Ü 150 E 1 F Ü R D I E ZU K U N FT G E DAC HT. The alwitra waterproofing system alwitra wall flashing profiles are part of the practically
More informationThe Passive Fire Protection Handbook
Uniclass L5:P:N3 CI/SfB Rf9 EPIC E:X:Y41 (K)+(K3) December 003 NBSPlus The Passive Fire Protection Handbook VICUCLAD VICUCLAD Applications Fire protection of metal ducts Construction of smoke extract ducts
More informationPolyCarb has good resistance to many chemicals. Some chemicals may harm the PolyCarb sheets. Contact us when in doubt about any chemical.
Polycarbonate Panels This manual provides the basic information for working with and installing PolyCarb sheets. Due to their hollow core, prior preparation is needed before the actual installation, with
More informationArchitectural Interior Wall Paneling
Architectural Interior Wall Paneling Compact Laminate Arpa Compact Laminate is comprised of reinforced wood fibres and thermosetting resins which when manufactured under very high pressure and heat produce
More informationSTACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS
STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS 1290363 Revision 1 12/16 Page 1 Weather Shield Mfg., Inc. NOTICE CAUTION! Failure to install and maintain our product according to these instructions
More informationInstallation Manual SOLID CORE SIDING
Installation Manual SOLID CORE SIDING SOLID CORE SIDING Installation Information contained in this manual can be viewed in video form at: www.youtube.com/epbc CONTENTS Important Notes...2-4 Weather Protective
More informationFibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.
Plank joint 600mm stud crs 600mm 600mm 600mm Horizontal Structural Timber Cavity atten 50x20mm H3.1 atten fixing points 800mm 800mm 300mm 800mm Max. Nog spacing 50mm All intermediate battens to be 50x20mm
More informationINSTALLATION GUIDE DUOFUSE SLAT WALL SYSTEM
06/2013 ENG 1 INSTALLATION GUIDE DUOFUSE SLAT WALL SYSTEM The Duofuse wood composite slat wall system is much more durable than wooden fences, and correct installation is necessary to enjoy the fences
More informationPRIMED STRAND REVERSIBLE SHAKE
PRIMED STRAND REVERSIBLE SHAKE PRIOR TO INSTALLATION Inspect product for any issues before installing (breakage, surface defects, foreign objects). Do not install questionable product. Report any problems
More informationSeries Sloped glazed Curtain wall. Installation Instructions
Series 5600 Sloped glazed Curtain wall Installation Instructions Part NO. Y308 February 2013 SECTION TABLE OF CONTENTS PAGE I. General Notes & Guidelines. 3-4 II. Gutter and Mullion Assembly.. 5 III. End
More informationCOMPOSITE RAILING INSTALLATION
COMPOSITE RAILING INSTALLATION Tools All you ll need is a hammer and screw gun, circular saw (carbidetipped blade with fewer than 20 teeth is recommended), level, tape measure, rasp and blue chalk line.
More informationinstallation care & maintenance instructions moistureshield.com limited lifetime warranty
installation care & maintenance instructions 866.729.2378 moistureshield.com limited lifetime warranty It s comforting to know that you re about to build a deck that gives you every possible advantage.
More informationInstallation Manual for Thermo Panel
Installation Manual for Thermo Panel 1 About Thermo Panel is a building wrap, insulation, air and water barrier, mold inhibitor and cold bridge eliminator all-in-one. Delivering an R-value of up to 5 on
More informationmaintenance-free free from painting easy to install Fixing Guide Cedral Lap
maintenance-free free from painting easy to install Fixing Guide Cedral Lap www.cedralsidings.com CONTENT Step by step guide to installing your Cedral façade Required materials and tools 1. Prepare wall(s)
More informationinstallation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty
installation care & maintenance instructions lifecycledecking.com 25-year limited residential warranty 20-year limited commercial warranty Installation Instructions As with any building project, use proper
More informationMetal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions
PO Box 480 Ph: 417-235-7821 Monett, MO 65708 Fax: 417-737-7140 Metal & Vinyl, Flush Mount and Recessed Fin Windows Recommended Installation Instructions These installation instructions are recommendations
More informationInstallation Guide (888)
BamDeck Installation Guide (888) 788-2254 The Collection Decking Systems BAMDECK 3G 5-7/16 Wide Plank Dims: 96 L x 5-7/16 W x 13/16 H BAMDECK 3G 16FT. 5-7/16 Wide Plank Dims: 192 L x 5-1/2 W x 13/16 H
More informationKS SERIES - VERTICAL INSTALLATION
CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV
More informationDura-Lock Roof System
DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.
More informationXL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS
XL JOINERY LTD LA PORTE VISTA MODULAR 3 2090mm High x 4687mm Wide ASSEMBLY INSTRUCTIONS READ AND UNDERSTAND THESE INSTRUCTIONS FULLY PRIOR TO STARTING INSTALLATION. IT IS STRONGLY RECOMMENDED THAT A COMPETENT
More informationSTEEL FRAMING WEATHERBOARD SYSTEM
T A R A NAK IPINE STEEL FRAMING WEATHERBOARD SYSTEM Installation information and technical drawings TIMBER WEATHERBOARDS NATURALLY BETTER FOR MORE THAN A CENTURY www.taranakipine.co.nz T A R ANAKIPINE
More informationEaves Lining Installation Guide
Eaves Lining Installation Guide feb 13 Design Pine Eaves Lining - Installation Like most building products, Design Pine eaves lining has both advantages and limitations therefore a clear understanding
More informationInstallation Guide. Guardian Slate Roof System. England, Scotland & Wales
Installation Guide Guardian Slate Roof System England, Scotland & Wales March 2016 Product Information Construction: Manufactured from resin bonded crushed limestone Size (slate): 445 x 294mm (ridgecap):
More informationRead guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.
Installation Guide for E-Series/Eagle High-Performance Mullion Windows with LVL Reinforcement and Installed Using Type B Clips Thank you for choosing Andersen. Instructions are for typical, new wood-framed
More informationHOW TO INSTALL ELITE PANELED WAINSCOTING Using X-Rails with Either Raised, Flat or Beaded Panels
HOW TO INSTALL ELITE PANELED WAINSCOTING Using X-Rails with Either Raised, Flat or Beaded Panels 1. First, remove the cover plates from all electrical outlets. All baseboards should also be removed; the
More informationFir and pine wood (52 %) Portland cement (38 %) made by firing limestone and clay Water (9 %) Wood mineralisation substances (1 %)
Duripanel Structura Product information sheet 1 1 Product composition Duripanel Structura fibre panels are made from: Fir and pine wood (52 %) Portland cement (38 %) made by firing limestone and clay Water
More informationEXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS
External EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS Parklex Facade may be installed using mechanical fasteners, such as screws or rivets. The panels are attached to vertical battens. In the event that
More informationWINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS
WINDOW REPLACEMENT INSTRUCTIONS FOR CASEMENT, DOUBLE-HUNG AND CLAD FRAME WINDOWS USING FRAME SCREWS These instructions were tested developed for replacing windows in wood-frame wall construction systems
More informationRoll-Fix Kit The complete dry hip kit RFIG
H I P Roll-Fix Kit The complete dry hip kit RFIG.045-0906-1 Roll-Fix is a quick and simple dry-fix roofing kit for hips. l Quick and easy to install no special tools required l Universal application fits
More informationInstallation Guide (888)
BamDeck Installation Guide (888) 788-2254 The Collection Decking Systems BAMDECK 4G 5-7/16 Wide Plank Dims: 192 L x 5-7/16 W x 13/16 H BAMDECK 4G WIDE 8-1/4 Wide Plank Dims: 96 L x 8-1/4 W x 13/16 H BAMDECK
More informationUlltraclad Aluminium Cladding. Contents. 1.0 General Information Design Information Installation Information 7. 4.
Ulltraclad Aluminium Cladding Contents 1.0 General Information 2 2.0 Design Information 4 3.0 Installation Information 7 4.0 Maintenance 10 5.0 Health & Safety 10 1 1.0 General Information 1.1 Introduction
More informationSun Windows General Information New Construction Hinged Door Installation Instructions
A G H F H H A. Apply Weather Resistive Barrier B. Apply Bottom Flashing Tape C. Install Sill Pan End Caps & Pan D. Caulk Sides & Top Nailing Surface, Set Door, Fasten E. Apply Side Flashing Tape F. Apply
More information50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated
50948-RHN Putney 06 January 2018 This document includes: Code Section Revision Dated H72 Aluminium strip/ sheet coverings/ flashings 1 Table of Contents Title H72 Aluminium strip/ sheet coverings/ flashings
More informationInstallation Guide GRP Dormer
Installation Guide GRP Dormer To ensure optimum performance please follow the correct fitting procedures outlined in this installation guide. Site safety and good building practice should be adhered to
More informationSTRUCTURAL PERFORMANCE OF TIMBER EXTERNAL CLADDING
STRUCTURAL PERFORMANCE OF TIMBER EXTERNAL CLADDING David Crawford 1 Dr Robert Hairstans 2 Ivor Davis 3 ABSTRACT: Although timber cladding has been used for centuries, the current design guidance for timber
More informationCOMPONENTS OF THE CLICKFAST FASCIA AND GUTTER SYSTEM 5: INTERNAL MITRE
INTRODUCING THE CLICKFAST FASCIA AND GUTTER SYSTEM The Clickfast Fascia and Gutter System was originally designed by Stratco and has proven to be the most successful fascia and gutter system in Australia
More informationLuxCore Installation Instructions
LuxCore Installation Instructions ATTENTION: LuxCore PANELS MUST BE ACCLIMATIZED FOR 24 HOURS BEFORE INSTALLATION PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLATION The guidelines provided herein have
More informationMethod of Build 1. Fire. Sound
Method of Build 1 General Viso Fire & Acoustic in the solid form differs from most other systems as it can be erected using 12.5mm & 15.0mm boards within the same Aluminium framework. Also hidden fix board
More informationVinyl Windows and Doors Manufactured by Pella Corporation
Vinyl Windows and Doors Manufactured by Pella Corporation Part Number: V981255 2009 Pella Corporation INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACIÓN FOR BOW WINDOWS WITHOUT HEAD AND SEAT BOARD
More informationBalustrade Systems / Installation Instructions
A. PARTS AND SUPPLIES NEEDED FOR INSTALLATION Hardware included for each 10 section of rail: 2 3 x 1-1/2 L-brackets 4 1-3/4 x 3/16 Blue hex-head screws for anchoring the L-brackets to the newel cap, column
More informationBest Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications.
Best Materials LLC distributes backer rod, caulking and sealants for all types of EIFS joints and penetration sealing applications. EXTERIOR INSULATION & FINISH SYSTEM CONSTRUCTION Data Published Courtesy
More informationContents. Installation Guide. Dynex Soffit Installation Guide V03 March The Smart Choice in Soffit
The Smart Choice in Soffit Installation Guide Looks great - A contemporary tongue and groove styled soffit, with hidden fixings, that provides a versatile and sleek lining complimenting a range of building
More informationWestern Red Cedar Shingles Product Guide
Western Red Cedar Shingles Product Guide Western Red Cedar Shingles & Shakes from John Brash are a truly renewable and sustainable roofing and cladding material; with one of the lowest carbon footprints
More informationSteel Reinforced Joining Thank you for choosing Andersen. Please leave this guide with building owner.
Steel Reinforced Joining (Horizontal/Vertical) for Andersen 400 Series Woodwright & Tilt-Wash Double-Hung, Picture, and Transom Windows and 400 Series Double-Hung Half Circle and Flexiframe Specialty Windows
More informationKERRAFRONT INSTRUCTION FOR INSTALLATIONS AND USE. Cellular cladding FS-201 / FS-202. kerrafront.com
KERRAFRONT INSTRUCTION FOR INSTALLATIONS AND USE Cellular cladding kerrafront.com - 2 - SUMMARY Installation - general rules 3 Cladding boards - detailed description 4 Trims and accessories 5 Horizontal
More informationINSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG
2008 Pella Corporation Part Number: 80ED0101 INSTALLATION INSTRUCTIONS - INSTRUCCIONES DE INSTALACION FOR HURRICANESHIELD IMPACT-RESISTANT DOUBLE-HUNG, SINGLE-HUNG AND SIMULATED-HUNG Instrucciones en español
More informationSun Windows General Information New Construction Sliding Door Installation Instructions H F
A G B D C H F H E H A. Apply Weather Resistive Barrier B. Apply Bottom Flashing Tape C. Install Sill Pan End Caps & Pan D. Caulk Sides & Top Nailing Surface, Set Door, Fasten E. Apply Side Flashing Tape
More informationBARRELL VAULT BATTENLESS
i BARRELL VAULT BATTENLESS INSTALLATION GUIDE INSTALLATION NOTIFICATION The installation procedures demonstrated in this manual are recommended methods for the installation of the Gerard Barrel Vault battenless
More informationNEVADA ASSEMBLY INSTRUCTIONS
NEVADA ASSEMBLY INSTRUCTIONS BASE SIZE: 2.700m x 1.500m NEVADA Tools Required: Battery Drill Riveter Hammer Tape Measure Ladder Skillsaw Level Screwdriver - Flat 3/8 Hex Drive bit 8mm Hex Drive bit Drill
More informationTechnical product descriptions WORKTOPS STANDARD SLIM LINE. 1. Material thickness 38 mm. 2. Core/substrate material Chipboard
Technical product descriptions WORKTOPS I STANDARD 1. 38 mm 2. Chipboard 3. Surface material Laminate (CPL, HPL) 4. Laminate thickness 0,6-0,8 mm 5. Surface structure Wood pore or relief, matt, gloss 6.
More informationSuperFOIL Insulation. Solutions Guide. Pitched Roof - Under Rafter
SuperFOIL Insulation Solutions Guide Pitched Roof - Under Rafter SF19+ Pitched Roof Under Rafter Solutions CONSTRUCTION THICKNESS R -VALUE EXTERNAL SURFACE - 0.040 TILES / SLATES 10mm - BATTEN CAVITY 25mm
More informationSeries 1500 Aluminum Door Canopy
Series 500 Aluminum Door Canopy with Sidewings It is our recommendation that you read instructions carefully prior to assembly and installation. Series 500 with Sidewings mounting bar (A) top trim (B)
More informationThe Passive Fire Protection Handbook
Uniclass L5:P:N3 CI/SfB Rf9 EPIC E:X:Y41 (K)+(K3) December 003 NBSPlus The Passive Fire Protection Handbook SUPALUX SUPALUX Applications Timber and steel frame partitions Single skin solid wall Fire protection
More informationINSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS
2008 Pella Corporation Part Number: 803V0101 INSTALLATION INSTRUCTIONS IMPERVIA SLIDING PATIO DOOR WITH FINS Installation Instructions for Typical Wood Frame Construction. These instructions were developed
More informationShapes Siding. Perfection Shingles. Chalk Line
Snap a Chalk Line Shapes Siding Perfection Shingles Chalk Line To establish a straight reference line to guide the positioning of the starter strip and the first course of siding, snap a chalk line. starter
More informationThe Passive Fire Protection Handbook
Uniclass L5:P:N3 CI/SfB Rf9 EPIC E:X:Y41 (K)+(K3) December 003 NBSPlus The Passive Fire Protection Handbook MASTERBOARD MASTERBOARD Applications Partitions Ceilings Wall and roof linings Soffit, porch
More informationSystem for 2+ Level Buildings
Issued Sept 205 Contact Info@symonite.co.nz System for 2+ Level Buildings Typical Details Issued: September 205 TYPICAL DETAILS CONTENTS.0 TYPICAL VERTICAL JOINTS 2.0 EXT. CORNER / TYPICAL HORIZONTAL JOINT
More informationINSTALLATION INSTRUCTIONS TRI-ROOF. energy for a better world
energy for a better world INSTALLATION INSTRUCTIONS TRI-ROOF The flexible roof integration system Compatible for framed module types* Simple exchange of modules Replaces existing roofing Special profiles
More informationFaçade CUT-TO-SIZE FAÇADE STRIPS APPLICATION IN OVERLAP ON WOODEN SUPPORTING STRUCTURE APPLICATION INSTRUCTIONS 1 1. GENERAL
Façade CUT-TO-SIZE FAÇADE STRIPS APPLICATION IN OVERLAP ON WOODEN SUPPORTING STRUCTURE APPLICATION INSTRUCTIONS 1 1. GENERAL These application instructions are specifically intended for the fastening of
More informationINSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO
2008 Pella Corporation Part Number: 801V0101 INSTALLATION INSTRUCTION INSTRUCCIONES DE INSTALACIÓN FOR CLAD HINGED PATIO DOOR PUERTA DE BISAGRA PARA PATIO REMEMBER TO USE APPROPRIATE PERSONAL PROTECTIVE
More informationWindows Installed into Walls with Polyiso and Wood Framing. Installation Instructions Standard Method Revised 10/24/2016
Windows Installed into Walls with Polyiso and Wood Framing Installation Instructions Standard Method Revised 10/24/2016 Background There are many acceptable ways to mount and detail windows for support
More informationWith Illustrations, Drawings & Step By Step Details. Click Here To Download 12,000 Shed Plans. 1 P a g e Download 12,000 More Shed Plans
With Illustrations, Drawings & Step By Step Details Click Here To Download 12,000 Shed Plans 1 P a g e Download 12,000 More Shed Plans Table of Contents OVERVIEW... 3 MATERIALS & CUTTING LISTS... 4 DRAWINGS,
More information