RX 3 ->CATALOG PAGES INSIDE. the global specialist

Size: px
Start display at page:

Download "RX 3 ->CATALOG PAGES INSIDE. the global specialist"

Transcription

1 RX 3 ESSENTIAL PROTECTION ->CATALOG PAGES INSIDE the global specialist IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

2 NEW RX 3 RANGE essential The new RX 3 range of RCDs and MCBs provides a response to the essential requirements on residential or small business sites, protecting against short-circuits, overloads and residual current faults. PROTECTION RCDs The breadth of the range covers the essential requirements of sites: C curves, 4500 breaking capacities and residual current protection In = 25 to 63 A 2P Sensitivity: AC type 30/100/300 ma Conform to standard IEC

3 IDEAL FOR BUILDINGS IN THE RESIDENTIAL AND SMALL BUSINESS SECTORS (OFFICES, SHOPS, ETC.) THERMAL-MAGNETIC CIRCUIT BREAKERS In = 6 to 63 A 1P/2P/3P Breaking capacity 4500 at 230/400 VA C curve Conform to standard SNI Conform to standard IEC

4 NEW RX 3 RANGE SAFE, RELIABLE AND EASY TO INSTALL safe, easy wiring: IP2X insulated terminals Large capacity terminals 35 mm 2 Rising clamp terminals Compatible with Phillips or flat screwdriver SIMPLE, VISIBLE MARKING Easy to use, visible marking area whatever the position of the handle Clear, simple, indelible marking for easy identification of the produc QUICK IDENTIFICATION OF THE FUNCTIONS 2 handle colours: Black for circuit breakers Grey for RCDs bistable clips: Easy positioning or removal of the product on its DIN rail 2

5 AIR FLOW AN ATTRACTIVE, WELL THOUGHT-OUT DESIGN FOR SAFETY AND COMFORT A well-designed shape and careful choice of material for the devices enables air to circulate, limiting any temperature rise between each circuit breaker Neat, attractive finish for greater ease of use RX 3 THE GUARANTEE OF A SAFE, RELIABLE RANGE Long-lasting electrical endurance Use under extreme conditions Optimum protection in the event of short-circuits Quality guaranteed by international approvals 10,000 operations -25 C to +70 C Limitation class

6 MCBs RX thermal magnetic MCBs from 6 A to 63 A C curves RCDs RX 3 residual current circuit breakers from 25 A to 80 A AC types Conform to IEC Conform to standard SNI Do not accept auxiliaries, and add-on modules Breaking capacity: IEC /400 V± 4.5 ka - IEC /400 V± Conform to IEC AC type?: detect AC component faults Pack Cat.Nos Single pole 230/400 VA C curve Nominal rating In (A) Number of modules pole 230/400 VA C curve Nominal rating In (A) Number of modules pole 400 VA C curve Nominal rating In (A) Number of modules Pack Cat.Nos RX 3 RCDs 2-pole V± AC type? 30 ma In (A) Number of modules AC type? 100 ma AC type? 300 ma RX 3 RCDs 4-pole V± neutral on right-hand side AC type? 30 ma In (A) Number of modules AC type? 100 ma AC type? 300 ma

7 supply busbars, entry terminals "standard" distribution NEW supply busbars, entry terminals "standard" distribution n Technical characteristics Max. Length Cross Permissible current: Busbars number in number section 1 central types of devices of 17.5 mm (mm 2 ) power 2 power connected modules supply point supply point Single pole or 1 row Single pole + neutral Meter Double pole 1 row Meter Double pole 1 row balanced on 3-phases Meter Triple pole 1 row Meter Four pole 1 row Meter Pack Cat.Nos Prong-type supply busbars Universal single pole + neutral Reversible: blue for neutral, black for live Length Max. number of devices connected row meter 57 n Use of supply busbars Universal single phase + neutral - blue for neutral - black for live Double pole row meter 28 Double pole balanced on 3 phases row meter 28 Triple pole row meter 19 Entry terminal Power supply at the rear of the busbar Power supply at the front of the busbar For all devices with moving cage For all devices with fixed cage terminals terminals Four pole row 1 meter 3 14 Protection Protection of prongs modules Can be cut to length Protection of supply busbar ends For single pole/single pole + neutral For double pole length 1 m and triple pole For four-pole Entry terminals For universal single pole + neutral or single pole supply busbars Cross section: 4 to 25 mm 2 - IP 2X For all supply busbars Cross section: 6 to 35 mm 2 Four pole busbar 1: Filled with end protection Red catalogue numbers: New products 5

8 flush-mounting cabinets Practibox TM 6 to 36 modules flush-mounting cabinets Practibox TM 6 to 36 modules Lateral, top and bottom knock-out entries Mounting of chassis with levelling system Faceplate with integrated door n Dimensions Cabinets 6,8 and 12 modules IP 40 - IK 07 with door Class II Conform to standard IEC 439 Reversible faceplate Box for masonry White RAL 9003 Supplied without terminal block E 72 A C Pack Cat.Nos Terminal shield boxes To be equipt with terminal blocks cat. no / row of 6 modules 1/ row of 8 modules 1/ row of 12 modules 1/ rows of 12 modules 1/ rows of 12 modules Accessories Blanking plate Separable into modules or 1/2 modules modules - white Terminal blocks Neutral and earth - 2 x 8 holes Key lock Only for 2 and 3 rows distribution cabinets N 850 Number of modules 6 mod. 8 mod. 12 mod. A B C D E Cabinets 24 and 36 modules C B A D B Number of modules 24 mod. 36 mod. A B C Bold pack quantities: Minimum quantities to be ordered

9 Notes

10 Notes

11

12 FOLLOW US ALSO ON PT. Intraco Indonesia Ruko Mahkota Ancol Blok C/50 Jl. R. E. Martadinata Kel. Pademangan Barat, Kec. Pademangan Jakarta Utara INDONESIA Authorized Distributor Of Telp. : : Fax. : info@intracoindonesia.co.id : PT. Intraco Indonesia World Headquarters and International Department Limoges Cedex - France Tel. : + 33 (0) Fax : + 33 (0) EXB September 2012

RX 3 ->CATALOG PAGES INSIDE. the global specialist

RX 3 ->CATALOG PAGES INSIDE. the global specialist RX 3 ESSENTIAL PROTECTION ->CATALOG PAGES INSIDE the global specialist IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW RX 3 RANGE essential The new RX 3 range of RCDs and MCBs provides a response

More information

NEW CIRCUIT PROTECTIONRANGE

NEW CIRCUIT PROTECTIONRANGE NEW CIRCUIT PROTECTIONRANGE TRUSTED PROTECTION FOR YOUR RESIDENTIAL AND COMMERCIAL INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW RCBO, RCCB AND MCB RANGE PROTECTION

More information

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE

DRIVIA cabinets LIMOGES Cedex France 1. DESCRIPTION, USE 3. DIMENSIONS 2. RANGE, CAT. NO. EQUIVALENCE TABLE 87045 LIMOGES Cedex France Tel: (+33) 05 55 06 87 87 Fax: (+33) 05 55 06 88 88 DRIVIA cabinets CONTENTS NTS PAGES 1. Description, use....1 2. Range, equivalence table...1 3. Dimensions...1 4. General characteristics...2

More information

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit

DPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit DPX TM MCCBs Description Cat. nos. ` / Pack DPX TM MCCBs Description Cat. nos. ` / Pack Auxiliary contact / Fault signalling contact DPX 125,160,250 ER 0261 60 804 1/24 250, 630, 1600, 1250 Under voltage

More information

COPYTRACER Anti-counterfeit registration number

COPYTRACER Anti-counterfeit registration number COPYTRACER Anti-counterfeit registration number Bottom clamp Environment friendly 36 New top clamp for all tools Technical labelling area Integrated label holder DX 3 The Next Step. Presenting, DX 3, an

More information

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole

Add-on modules DX 3 63A for MCBs DX 3 1,5 modules per pole 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 Add-on modules DX 3 63A for MCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4.

More information

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A

NIRAPOD 1. High performance circuit breaker mcb and combined mcb with remote controls. LV Distribution Products 2-63A High performance circuit breaker mcb and combined mcb with remote controls LV Distribution Products 2-63A Mini motorized circuit breaker The mini-series of motorized circuit breakers operates both locally

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 807-0 Fax: 0640 807-259 IT system floor-standing distribution cabinet Series -IPS-F/EDS for supplying power to medical locations

More information

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole

Btdin RCD Add-on modules 63A for MCBs 1,5 modules per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and

More information

Technical features table for miniature circuit-breakers SH 200 Series

Technical features table for miniature circuit-breakers SH 200 Series Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution

More information

THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES P. 20-21 DX³ - MCB AC Application upto 63 A MCBs P. 23 DX³ - 25 ka MCB from 6 A to 125 A Isolator RCCB & RCBOs

More information

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127

Section five. Connection systems. Isobar 4 Evo MCB pan assemblies Mulitclip busbar and Polybloc 126. Comb busbars 127 Connection systems Section five Isobar 4 Evo MCB pan assemblies 122 1 Mulitclip busbar and Polybloc 126 Comb busbars 127 Terminals and installation accessories 128 129 121 Isobar 4 Evo MCB pan assemblies

More information

sustainable savings that can be viewed directly on the internet

sustainable savings that can be viewed directly on the internet sustainable savings that can be viewed directly on the internet MEASUREMENT, METERING & DISPLAY VIA e COMMUNICATION Measurement, metering and display, the first step towards sustainable savings Measurement,

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

Trunkingxxxxxx. in aluminium. Industrial Catalogue

Trunkingxxxxxx. in aluminium. Industrial Catalogue 93 Trunkingxxxxxx in aluminium Industrial Catalogue 151 TRUNKING 93 IN LUMINIUM Trunking 93 in aluminium To mount switches and sockets in environments requiring neat finishing Free choice of switches and

More information

Cable Management Solutions with DLP TM

Cable Management Solutions with DLP TM DLP trunking system P. 374-375 Selection chart for DLP trunking system P. 397 Floor boxes & Under floor boxes Technical data P. 373 DLP U-PVC adaptable trunking system Cable Management Solutions with DLP

More information

PHOENIX CONTACT

PHOENIX CONTACT Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode

More information

Trunkingxxxxxx. aluminium colour U23X. Industrial Catalogue

Trunkingxxxxxx. aluminium colour U23X. Industrial Catalogue in U23X 93 Trunkingxxxxxx aluminium colour Industrial Catalogue 127 Trunking 93 IN U23X aluminium colour Trunking 93 in U23X aluminium colour Designed to fit in the most demanding architectural and decorative

More information

PHOENIX CONTACT

PHOENIX CONTACT Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24

More information

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR The flexibility of the Zucchini MS range during planning and installation makes it ideal for frequently changing requirements in small to medium sized commercial

More information

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE

RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE RCP IP68 RESIN BUSBAR TRUNKING GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURE IP68 RCP RESIN BUSBAR TRUNKING New resin busbar RCP ranging from 6 A to A and IP68 degree of protection,

More information

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts

5/2 Introduction. Unequipped Distribution Boards 5/4 Modular distribution boards 5/5 Add-on parts ALPHA AS Modular Distribution Boards /2 Introduction Unequipped Distribution Boards /4 Modular distribution boards / Add-on parts Assembly Kits for Unequipped Distribution Boards /6 8GK4 assembly kits

More information

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION

More information

Measuring current transformers of the W, W series

Measuring current transformers of the W, W series Measuring current transformers of the W, W -8000 series W(-8000)_D00078_01_D_XXEN/09.2015 Measuring current transformers of the W, W -8000 series Product description The highly sensitive W and W -8000

More information

Page 13-2 Page Page 13-7

Page 13-2 Page Page 13-7 Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,

More information

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity.

C.A 6115N. Safety at all costs. IEE 16th: Electrical installation IEC/EN I E C. Insulation RCD. Earth. Loop. Continuity. IEE 16th: Safety at all costs C.A 6115N Electrical installation Insulation RCD Earth Loop Continuity Phase rotation I E C CONFIRMS TO CONFIRMS TO IEC/EN 61557 1010-1 III 300V Cat Cat The most complete

More information

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole

Btdin RCD Add-on Modules 32A - 63A for M.C.Bs 1 module per pole Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-6 6. Compliance - Approvals... 6 7. Curves... 7 1 / 7 1. DESCRIPTION

More information

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards

4/2 Introduction. Marshaling Boxes 4/8 8GK1 surface-mounting distribution boards ALPHA 630 - DIN Floor- Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards /5 8GK1 surface-mounting distribution boards, IP3 /6 8GK1 surface-mounting distribution boards, IP55 Marshaling

More information

Raised Floor system LIMOGES Cedex. Phone : Fax :

Raised Floor system LIMOGES Cedex. Phone : Fax : 87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Raised Floor system CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 10 3.Products détails 11 to 22 4.Technical characteristics

More information

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards

2/2 Introduction. Unequipped Distribution Boards 2/5 8GK1 surface and flush-mounting distribution boards Siemens AG 010 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quickassembly kits Unequipped

More information

DLP mini trunking. DLP U-PVC trunking system mini-trunking system. DLP U-PVC trunking system and accessories 80 x 50. Comfortable implementation

DLP mini trunking. DLP U-PVC trunking system mini-trunking system. DLP U-PVC trunking system and accessories 80 x 50. Comfortable implementation DLP mini trunking Cable-grip It makes the installation easier and faster by containing all the wires inside the trunking body before the cover is clipped Comfortable implementation During installation,

More information

Protective Relays Digitrip 3000

Protective Relays Digitrip 3000 New Information Technical Data Effective: May 1999 Page 1 Applications Provides reliable 3-phase and ground overcurrent protection for all voltage levels. Primary feeder circuit protection Primary transformer

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range

Residual Current-operated Circuit Breakers (RCCBs) F 360 and F 370 Range Technical data System pro M Residual Current-operated Circuit Breakers (RCCBs) System pro M 1 When connecting aluminium conductors ensure that the contact surfaces of the conductors are cleaned, brushed

More information

Residual current circuit breakers (RCCBs)

Residual current circuit breakers (RCCBs) Residual current circuit breakers (RCCBs) Description Automatically trips in event of earth leakage fault Provides protection against direct & indirect contact with live parts Technical data IS 12640-1,

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications

Circuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL

More information

Atlantic. ip40-ip65 Metal distribution switchboard. Certifications. Technical features. Electrical properties

Atlantic. ip40-ip65 Metal distribution switchboard. Certifications. Technical features. Electrical properties Atlantic ip40-ip65 Metal distribution switchboard Atlantic series is designed by metal cabinets combinations created for low Voltage electrical switchboards. This line of products show an innovative aesthetic,

More information

Fluke and

Fluke and Fluke 1623-2 and 1625-2 GEO Earth Ground Testers Technical Data The new Fluke 1623-2 and 1625-2 GEO Earth Ground Testers offer data storage and download capabilities via USB port. World class accessories

More information

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Miniature circuit-breakers S 280 UC series. System pro M. Technical data Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum

More information

FINAL - EST Electrical Service Technician Answer Schedule

FINAL - EST Electrical Service Technician Answer Schedule FINAL - EST 2069 - Electrical Service Technician Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the accepted answers to the examination questions.

More information

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

Local control stations for Zone 1 and Zone 21. Features. Description

Local control stations for Zone 1 and Zone 21. Features. Description Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning

More information

Installation / Monitoring Technique

Installation / Monitoring Technique Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and

More information

DATA SHEET. Switchboard instruments,

DATA SHEET. Switchboard instruments, DATA SHEET Switchboard instruments, types Standard DIN sizes Quadratic instruments: Q48 Q144 Edgewise instruments: 48 x 24 144 x 72 mm Slim edgewise instruments: 72 x 24 144 x 36 mm Accuracy class 1.5

More information

Protective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection)

Protective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection) Protective earthing, protective conductor and automatic disconnection in case of a fault (Fault protection) FIGURE 1.2 Fig.1 Earth fault loop path. Figure 1 shows the earth fault system which provides

More information

DATA SHEET Selectable AC transducer TAS-311DG

DATA SHEET Selectable AC transducer TAS-311DG DATA SHEET Selectable AC transducer Measuring on AC networks Class 0.5 (IEC688) measurement Supply/measur. voltage up to 690 V Easy configuration via PC interface possible DEIF A/S Frisenborgvej 33 DK-7800

More information

DLP-S Trunking LIMOGES Cedex. Phone : Fax :

DLP-S Trunking LIMOGES Cedex. Phone : Fax : 87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 SOMMAIRE PAGES 1.Trunking 1 to 2 2.Accessories 3 to 7 3.Technical chacteristiques 8 4.Material chacteristiques 8 1. TRUNKING. DLP-S trunking

More information

ConnectionSolutions 4Workplaces. general catalogue

ConnectionSolutions 4Workplaces. general catalogue ConnectionSolutions 4Workplaces general catalogue 2011-2012 Simon TRUNKING 06 FOR DIRECT SNAP-FIT K45 MECHANISMS C Specifications: Material: PVC and anodisedaluminium trunking. White and paintedaluminium

More information

Flush Floor system LIMOGES Cedex. Phone : Fax :

Flush Floor system LIMOGES Cedex. Phone : Fax : 87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 8 3.Products détails 9 to 18 4.Technical characteristics 19 to 21 1 RANGE. Lid

More information

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke s A6V10628469 ACVATIX Electromotoric actuators for valves SAY..P.. with a 15 mm stroke SAY31P03 Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10

More information

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique

Protection and control. Sepam range Sepam 100 LA Self-powering protection. Merlin Gerin Square D Telemecanique Protection and control Sepam range Sepam 0 LA Self-powering protection Merlin Gerin Square D Telemecanique presentation contents page presentation protection functional and connection schemes other connection

More information

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required

More information

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION) GENERAL MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION) SUBMITTED BY SASHIKUMAR G BHARAT HEAVY ELECTRICALS LIMITED INDUSTRIAL SYSTEMS GROUP Prof. C. N. R. Rao Circle I. I. Sc. POST Malleswaram Bangalore

More information

Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault 1SDC007402G0201

Integration between the MV protection and control unit REF542 and the LV protection trip unit PR123: selectivity and earth fault 1SDC007402G0201 1SDC007402G0201 Index 1. Introduction... 2 2. Theoretical outline 2.1 Restricted earth fault... 3 2.2 Selectivity between medium and low voltage... 4 3. Application examples and wiring logic 3.1 Restricted

More information

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar Fig. 1. Isolating amplifier RISH Ducer TV 808 in housing S 17 clipped onto a top - hat rail or screw hole mounting brackets pulled out. Features and Benefits Electric Isolation between input, and power

More information

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Current / residual current and voltage transformers. Current / residual current and voltage transformers Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A Load break switches standards UL and CSA The solution for Load break switches sircm_1_a_1_cat > Power distribution Strong points Function Rotary switch SRCO M 3 x 1 A SRCO M load break switches are compact

More information

Circuit protection devices

Circuit protection devices Circuit protection devices MCBs, RCCBs, RCBO, ELR, surge arresters, fuse carriers, complete range of auxiliaries, busbars and connectors EA 2002/1 Welcome to the new edition of our general catalogue For

More information

Technical Data Accessories MCCBs Ex9M.

Technical Data Accessories MCCBs Ex9M. Auxiliary and signal contact units AX21, AL21 Contact units for auxiliary and signal contact functions are suitable for both M1 and M2 frame sizes It is possible to use ap to two units of AX21 plus 1 unit

More information

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION

CDV 22, 62. Voltage Controlled Overcurrent Relay GRID PROTECTION PROTECTION CDV 22, 62 Voltage Controlled Overcurrent Relay CDV22 relay is used for overload and fault protection for ac generators when the sustained short circuit current is less than the full load current.

More information

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and

More information

ALPHA DIN Wall-Mounted. Distribution Boards

ALPHA DIN Wall-Mounted. Distribution Boards Siemens AG 008 ALPHA 160 - DIN Wall-Mounted Distribution Boards / Introduction Distribution Boards with Built-In Distribution Board Panels /4 8GK1 surface and flush-mounting with quick-assembly kits Unequipped

More information

OptiLine 45 Floor boxes

OptiLine 45 Floor boxes OptiLine 45 Floor outlet boxes P89490 Type Colour Dimensions A/B/C (mm) Qty per pack Ref. No. Floor outlet box including mounting frames for Altira, trim frame with four quick-fix devices and lid with

More information

Technical catalogue. Emax Low voltage air circuit-breakers. Hotline:

Technical catalogue. Emax Low voltage air circuit-breakers.   Hotline: Technical catalogue Emax Low voltage air circuit-breakers www.alobitanbd.com Hotline: 01711548558 PAGE : 02 The new Emax have received innumerable international certifications and approval by the major

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light.

isw switches Control Local control IEC/EN , isw switch with indicator light. IEC/EN , isw switch without indicator light. isw switches DB88 PB0566-40 Position contact indication b Suitable for industrial isolation according to IEC/EN 60947-3 standard. b The presence of the green strip guarantees physical opening of the contacts

More information

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented

FIB / FIC. r with Overcurrent Protection (RCBO) Doepke. » effi cient. » reliable. » fl exible. » future-oriented Doepke The experts in residual current protection technology Residual Current Circuit-Breakers it- r with Overcurrent Protection (RCBO) FIB / FIC» effi cient» reliable» fl exible» future-oriented Doepke

More information

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors

Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL77/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the UL489/CSA C22.2 No.5-02,

More information

Single phase meter with direct connection and pulse or Modbus RS485 output

Single phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 Fax: +33(0)5 55 06 88 88 Single phase meter with direct connection CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

8 Input/8 Output AC Block I/O Module

8 Input/8 Output AC Block I/O Module 8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.

More information

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Industrial Controls. Catalog IC SIRIUS. Answers for industry. Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor

More information

GLS A GLS 15

GLS A GLS 15 GLS 25-40-63A GLS 15 GLS Graziadio Busbar Graziadio have been making busbar in Italy since 1959. Originally founded by Antonio Graziadio. The company continued to expand its sales and product ranges within

More information

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole

MULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole MULTIBLOC 00.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 00.ST8 comprises NH fuse switch disconnectors for 160A. They are designed for bottom

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

Low voltage switchgear

Low voltage switchgear Low voltage switchgear Sivacon S8 and 8PT Withdrawable core structure designed for demanding applications and international markets. SAT8 PU0 Main exchange system for demanding fixed output, industrial

More information

Siemens AG New portfolio for reliable personnel, material and fire protection

Siemens AG New portfolio for reliable personnel, material and fire protection s Siemens AG 2016 SENTRON 5SV9 Compact RCBOs New portfolio for reliable personnel, material and fire protection Reliable personnel/ investment protection This combination of residual current operated circuit

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

Flexible AC current probes

Flexible AC current probes Flexible AC current probes Making use of the principle of Rogowski coils, the MiniFLEX models are flexible sensors offering a wide dynamic range for measuring AC intensities and viewing high-speed current

More information

LBPLUS DATA. he new busbar unking system for LIGHTING MANAGEMENT. Range

LBPLUS DATA. he new busbar unking system for LIGHTING MANAGEMENT. Range LBPLUS DATA The he new busbar trunking unking system for LIGHTING MANAGEMENT, the new busbar conceived for distribution and lighting in the service sector, which integrates a BUS that can be used for Lighting

More information

Basic Series Square Panel Meters Features Benefits

Basic Series Square Panel Meters Features Benefits Features Benefits Worldwide sales and service All panel meters can be supplied ex stock 1) Shunt resistors without protective cover (nominal current up to 1.5 ka) ASK 31.3 / ASK 412.4 current transformers

More information

10. Mini Coax Connectors

10. Mini Coax Connectors . Connectors The allows multi-pole coaxial data transmission for board-to-board, cable-to-board and cable-to-cable applications with protection up to IP 65 / IP 67. At the same time, applications up to

More information

Measuring current transformers of the W B series

Measuring current transformers of the W B series Measuring current transformers of the W B series W-B_D00075_01_D_XXEN/09.2015 Measuring current transformers of the W B series Product description Measuring current transformers of the W B series are highly

More information

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke s A6V10628469 ACVATIX Electromotoric actuators for VPI46 SAY..P.. with a 15 mm stroke Operating voltage AC 230 V, 3-position control signal Operating voltage AC/DC 24 V, control signal DC 0 10 V, 4 20

More information

3-phase meter with direct connection and pulse or Modbus RS485 output

3-phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 3-phase meter with direct connection and CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD)

from 0.5 to 125 A Electrical characteristics Sensitivity type (ma) a AC Electrical auxiliaries Auxiliary and alarm switches (OF-SD) Acti 9 Acti 9 circuit reakers from 0.5 to 125 A 056903N-32_SE.eps 056806N-28_SE.eps PB104440_28.eps PB107141_28.eps Acti 9 circuit reaker C120N Numer of poles 1 2-3-4 Electrical characteristics Rated current

More information

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke s 4 509 ACVATIX Electromotoric actuators for valves SAX..P with a 20 mm stroke SAX31P.. Operating voltage AC 230 V, 3-position control signal SAX61P.. Operating voltage AC/DC 24 V, control signal DC 0

More information

RUDOLF Digital power analyzer. Advanced Version

RUDOLF Digital power analyzer. Advanced Version RUDOLF Digital power analyzer Advanced Version Digital power analyzer Advanced Version Company Introduction Bridex Singapore Pte Ltd is founded in 1978 as a manufacturer of instruments transformer for

More information

MISTRAL SYSTEM IMPACT 2

MISTRAL SYSTEM IMPACT 2 MISTRAL 25-40A SYSTEM 100-400A IMPACT 2 400-6300A Megabarre Group represents the perfect fusion of a global offer, a highly-qualified service and a great working efficiency. The certificated quality of

More information

Introduction. Centrado leading-edge transformer. Introduction

Introduction. Centrado leading-edge transformer. Introduction Introduction Centrado leading-edge transformer products are designed to optimize safety and produced to deliver a great electrical power experience and solution - for factory, infrastructure, home industry,

More information

Ceiling Mount - 32" to 60" - Single Installation Instructions

Ceiling Mount - 32 to 60 - Single Installation Instructions Ceiling Mount - 32" to 60" - Single Installation Instructions Important Safety Information Use proper safety equipment during installation If you don't understand the installation instructions, have any

More information

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion

More information

Output of three-phase motors at 50 Hz and 400 V

Output of three-phase motors at 50 Hz and 400 V RT0, RH Coupling Relays (Interfaces) Description DC operation IEC 0 947 and EN 0 947 (VDE 00) The RT0 coupling relays for switching motors and RH for auxiliary circuits are laid out to the special requirements

More information

10. Mini Coax Connectors

10. Mini Coax Connectors . Connectors The allows multi-pole coaxial data transmission for board-to-board, cableto-board and cable-to-cable applications with protection up to IP65 / IP67. At the same time, applications up to 2.5

More information

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request Euromas Polymas Detailed product information can be found on www.bopla.de - 5 sizes - Versions with or without screwing systems - Quick-release fastener versions - Transparent lids on request - Terminals

More information

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!

More information

EMC filters. Mounting instructions. Date: January 2006

EMC filters. Mounting instructions. Date: January 2006 Date: January 2006 EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS prior express consent is prohibited. EMC cannot be assured

More information