sustainable savings that can be viewed directly on the internet
|
|
- Nathaniel Burns
- 6 years ago
- Views:
Transcription
1 sustainable savings that can be viewed directly on the internet MEASUREMENT, METERING & DISPLAY VIA e COMMUNICATION
2 Measurement, metering and display, the first step towards sustainable savings Measurement, metering & display via e communication Measurement is the basis of all diagnostics. By monitoring your consumption, you can make savings of 8 to %. And by combining this with action plans, you can optimise performance and commit to a sustainable development process. Energy efficiency requirements in commercial buildings will encourage the use of measurement by load type, in each consumer unit, with consumption displayed as close as possible to the user (heating, cooling, hot water production, lighting, cooking, power sockets). Legrand solutions In addition to energy meters, measurement control units and the new DX or DPX protection devices incorporating measurement functions, Legrand has developed an e communication infrastructure for displaying information on reactive power consumption, voltage disturbance, harmonic distortion, etc. according to the type of building (low consumption/high environmental quality, whether in use or being refurbished). LIGHTING Electricity meter at head of row Installation of web server, electricity meters and measurement control unit, combined with corrective actions HEATING/AIR CONDITIONING Electricity meter at head of row Potential savings for a set of electrically heated offices 600 m ANNUAL SAVING 800 Payback 4 months max. () ANNUAL SAVING 00 kg CO equivalent CO equivalent of all polluting gases (CO, methane, carbon monoxide, fluorinated gases, etc.) ANY APPLICATION Measurement control unit () at the supply end of the installation with checking of the electrical parameters () Meters and control units are protected upstream by 0.5 A fuses () Prices and data for information only valid in France.
3 DISPLAY IN THE CONSUMER UNIT DISPLAY AS CLOSE AS POSSIBLE TO USERS Directly on the internet and on tablet computers equipped with a web browser (ipad, Archos, etc.) or smartphones (iphone, etc.) Measurement via e communication on fixed and mobile screens Display of the measurement on a screen connected to the IP network with web server, displaying data from measurement control units and EMDX electricity meters. CENTRALISED DISPLAY FOR OPERATING MANAGERS Measurement via e communication on PC screen Remote display, for a set of buildings, of the measurement information from various main LV distribution boards (MB) or secondary boards (SB). One IP address per consumer unit. Used for the real-time display, measurement and recording of consumption.
4 Build an architecture for measurement via e communication Measurement, metering and display via e communication : Each consumer unit has an IP address Main LV distribution board Measurement on each direct outgoing line RS 485 FIELDBUS RS 485/IP converter Cat.No DIRECT OUTGOING LINE FROM 80 A Secondary board Essential measurements New buildings Electronic circuit breaker with measurement unit For measuring consumption, voltage, current, active power, etc. Operates with electronic interface Cat.No DIRECT OUTGOING LINE FROM 80 A RS 485 FIELDBUS RS 485/IP converter Cat.No OUTGOING LINE TO AIR CONDITIONING/HEATING EMDX Access and Premium measurement control unit with module for temperature measurement, event log, remote control, measurement of harmonics, etc. OUTGOING LINE TO LIGHTING DIRECT OUTGOING LINE FROM 80 A OUTGOING LINE TO POWER SOCKETS EMDX modular measurement control unit OTHER RS 485 electricity meters For recharged metering, use MID certified meters RS Fieldbus Pulse link IP protocol - Ethernet bus
5 IP PROTOCOL - ETHERNET BUS Secondary board Extension of measurements, (positive energy buildings), existing buildings DIRECT DISPLAY ON SCREEN (WITH SOFTWARE OR WEB SERVER, see page 5) MB For example at each outgoing line, display and measurement of harmonics, consumption history PULSE EMDX modular concentrator RS 485 RS 485/IP converter Cat.No Each application is detailed (heating/lighting/ measurement can be extended to water and gas meters). For each one, the consumption only is measured by a pulse energy meter connected, in groups of 7 meters, to a concentrator SB For example low consumption/high environmental quality building. Detailed measurements for each application SB Consumption history per previous days, months and years Pulse energy meters For recharged metering, use MID certified meters
6 Build an architecture for measurement via e communication Measurement, metering & display via e communication : Each consumer unit has an IP address Main LV distribution board Essential measurements RS 485 FIELDBUS IP PROTOCOL ETHERNET BUS RS 485/IP converter Cat.No BOILER ROOM CONSUMER UNIT OUTGOING LINE OUTGOING LINE TO AIR CONDITIONING Web server Enables consumption to be displayed on all types of screen equipped with a web browser (PC), Smartphone (iphone, etc.), TV, tablet computer equipped with a web browser (ipad, Archos, etc.) 4 OUTGOING LINE TO LIGHTING OUTGOING LINE TO POWER SOCKETS OTHER RS 485 electricity meters For recharged metering, use MID certified meters Software dedicated to measurement For displaying measurement or metering on a dedicated PC RS Fieldbus IP protocol - Ethernet bus
7 GLOBAL IP DISPLAY DIRECTLY ON THE INTERNET WITH THE WEB SERVER e communication The consumer unit's consumption per application is displayed, via the web server, on a screen connected to the network displaying, as required, all the parameters of the installation: consumption, energy, voltage, etc. ipad, Archos, etc. type tablet computer equipped with a web browser On PC On Smartphone* On TV* On tablet* * Direct display on screens equipped with a web browser, using the web server IP DISPLAY WITH LEGRAND SOFTWARE e communication Measurements from electricity meters or measurement control units (consumption, energy, voltage, etc.) are displayed, via the dedicated software, on a PC connected to the company network. 5 On PC
8 Configure a system for measurement via e communication in steps A simple, intuitive application for complete display of the consumption of a building To use remote display with the web server: - If you are on a company network, ask you IT department for a fixed IP address - If you have a box, ask your service provider for a fixed address solutions for displaying the consumption of buildings: Installation of the Measurement application on a dedicated PC, or direct connection to a web server. Then, directly configure (in steps) the display of the consumption of the buildings PC Tablet* TV* * Direct display on screens equipped with a web browser, using the web server Smartphone* EXAMPLE OF CONFIGURATION OF THE ELECTRICAL INFRASTRUCTURE OF A BUILDING BY CREATING CONSUMER UNITS, CIRCUITS AND AREAS 4 Add an item to the building: Add Consumer units Circuits (and predefined applications) Areas Name the items added: Consumer units Main LV distribution board Secondary board Examples of creating consumer units 6 Save Circuits (applications) Heating Lighting Example of screen for configuring a consumer unit. Repeat the same operations from the initial screen to create circuits and areas. Save Areas Building A 4 Display of the saved items SB - Bldg B - nd floor - Heating Building B - nd floor Examples of creating areas Save
9 EXAMPLE OF CONFIGURATION OF THE GATEWAY* (IP ADDRESS) OF A CONSUMER UNIT Add a gateway Add Enter the IP address of the consumer unit gateway Each consumer unit has its own IP address (via the gateway) Name the gateway Gateway 4 Select the assigned consumer unit Main LV distribution board 5 Save EXAMPLE OF CONFIGURATION OF DEVICES (MEASUREMENT CONTROL UNIT OR ELECTRICITY METER) AND AREAS OF A BUILDING Add a device Setting the parameters of a device Add Modular Designation of the meas. control unit (here ) Assign the Modbuss address 4 Each device has a communication address number Select the device 4 Name the device Meas. control unit 5 Load type Lighting 6 Set the parameters of an area Save 7 Assign the area(s) of the device Lighting area Save *Gateway: IP converter
10 Display the consumption of buildings with the e communication measurement application All the measurements can be accessed from a dedicated PC with software for measurement via e communication or on tablet computers (ipad, etc.), smartphones (iphone, etc.) and TV screens using the Legrand web server You can view all the readings taken (available in real time and historically), access the data by partial or total area and display the consumption or other electrical values PC Smartphone* TV* Tablet* * Direct display on screens equipped with a web browser, using the web server EXAMPLE OF DISPLAY OF A DEVICE (MEASUREMENT CONTROL UNIT OR ELECTRICITY METER) Select the type of display for the device: Gateway All (total measurement for the device) Gateway Table Display of selected device: Cent. control unit lighting 4 Select the type of measurement Example (with a measurement control unit) Energy 8 ON Energy 4 Power Power V/A/Hz Voltage Current Frequency THD Total harmonic distortion Display of the measurements Example of screen displaying the measurement of a central control unit with lighting circuit Example of display tables (energy, power and voltage)
11 EXAMPLE OF DISPLAY OF TOTAL CONSUMPTION Display of the consumption in real time Current month 0.0 MWh 0 k * Display of consumption and estimated cost in euros per current and previous year, month and day (example month) Selection of the graphic showing consumption per period Graphic period: Day Month Year Display of consumption graphic Example of screen displaying the total heating consumption of a device over a month EXAMPLE OF DISPLAY OF PARTIAL CONSUMPTION (BY AREAS AND CIRCUITS) Select an area Floor Select a circuit Heating Display of consumption Display of partial consumption per current and previous day, month and year EXAMPLE OF DETAILED DISPLAY OF ALL THE ELECTRICAL VALUES Select the type of measurement 4 Energy Energy Power Power V/A/Hz Voltage Current Frequency THD Total harmonic distortion Select the device Display of selected device 4 Display of consumption Detailed display of the energy consumption of the heating device per current and previous day, month and year *For information purposes only 9
12 EMDX multi-function measuring units A range tailored to your measurement, metering and display requirements High precision devices with complete communication functions Thanks to the new range you can: Analyze energy consumption and reduce your electrical bill Find weak points and unsymmetrical loads in customer networks Check the quality of supplied energy and document this Create a measuring network for a complete installation Create a cost monitoring for different consumers EMDX overview With pulse transmitter With RS 485 communication interface Access Premium Temperature storage module 0 Individual Harmonics 6 rd Harmonics 5 rd Communication RS 485 Communication pulse Double tarif U, V, I. Energy, THD, Demand, Custom Alarms
13 EMDX main functions With pulse transmitter With RS 485 communication interface Access Premium Instantaneous Current Maximum MEASURING Average Instantaneous Voltage Frequency Instantaneous Average Power Max,Min Predictive Power factor (instantaneous) Internal Temperature External (with plug-in module and sensors) METERING Active energy Reactive energy Apparent energy Hours run Harmonic distortion Harmonics current Phase to neutral voltage Phase to phase voltage Harmonics current individual Phase to neutral voltage Phase to phase voltage
14 EMDX electrical energy meters 4 rail mounting EMDX multi-function measuring units 4 rail mounting Technical characteristics p. 5 Technical characteristics p. 6 Measure the electricity consumed by a single-phase or three-phase circuit downstream of the electricity distribution metering Display electricity consumption in kwh, as well as other values such as current, active energy, reactive energy and power (depending on the catalogue number) Conform to standards IEC 605-/, IEC 605- and IEC 600- MID compliance ensures accuracy of the metering with a view to recharging for the electricity used Pack Cat.Nos Single-phase meters Non-MID MID compliant Direct connection A - module Pulse output A - modules Pulse output A - modules Pulse output A - modules RS485output Three-phase meters MID Non-MID compliant Direct connection A - 4 modules Pulse output A - 4 modules RS485output Connection with CT A - 4 modules pulse output A - 4 modules RS485and pulseoutput Conform to standards: - IEC IEC 605- class 0.5 S - IEC 605- class Pack Cat.Nos EMDX modular For mounting on rail Width: 4 modules LCD display Measurement of currents, voltages, active, reactive and apparent power and internal temperature Dual tariff metering: - Active energy consumed - Reactive energy consumed - Operating time -Powerfactor THD voltages and currents up to order 5 Programmable alarms on all functions Outputs for controlling wiring devices, alarm feedback and pulse feedback EMDX pulse unit Datatransmissionviapulses EMDX RS 485 unit DatatransmissionviaRS485communication interface and pulses Concentrator For collecting and transmitting measurements taken by 7 universal pulse electricity meters Also collects data from other meters (gas meters, water meters, etc.) RS485 output 4modules
15 EMDX multi-function measuring units for mounting on door or solid faceplate Technical characteristics p. 6 Conform to standards: - IEC IEC 605- class 0.5 S - IEC 605- class Pack Cat.Nos EMDX - Access Multi-function measuring unit For mounting on door or solid faceplate Dimensions: 96 x 96 x 60 mm LCD display Measurement of currents, voltages, active, reactive and apparent power, internal temperature and power factor Metering: -Activeenergyconsumedorproduced - Reactive energy consumed or produced - Operating time -Pulses THDvoltagesandcurrentsuptoorder5 Programmable alarms on all functions Can take optional modules Modules for EMDX - Access multi-function measuring unit RS485 communication module MODBUS link output module Can be assigned to pulse feedback, alarm feedback or control of wiring devices EMDX - Premium Multi-function measuring units For mounting on door or solid faceplate Dimensions: 96 x 96 x 60 mm LCD display Measurement of currents, voltages, active, reactive and apparent power, internal temperature and power factor Metering: -Activeenergyconsumedorproduced - Reactive energy consumed or produced - Operating time -Pulses Individualharmonicsuptoorder6 Programmable alarms on all functions Can take 4 optional modules Pack Cat.Nos EMDX - Premium (continued) Modules for EMDX - Premium multi-function measuring units RS 485 communication module MODBUS link Storage module Storage of active and reactive power over 6 days, the last 0 alarms and the average voltage and frequencyvaluesover60daysmax Module with inputs/ outputs Uptomodules,i.e.6inputs/6outputs,can be installed Outputs can be assigned to monitoring mode, remote control or timed remote control Temperature module Indication of the internal temperature and possibility of connecting sensors for measuring the external temperature Communication and supervision Web servers Enable remote viewing, via a web browser on PCs, smartphones, web viewers, tablet computers such as ipads, Archos, etc., of values collected on electricity meters and multi-function measuring units For metering points (meters or multi-function measuring units) Foranunlimitednumberofmeteringpoints(meters or multi-function measuring units) Legrand software dedicated to measurement For displaying the values collected from electricity meters or multi-function measuring units on a PC connected to the network For metering points (supplied on CD) Foranunlimitednumberofmeteringpoints(supplied on CD) IP converter For RS485/Ethernet conversion for connecting electricity meters and multi-function measuring units toanip network
16 current transformers CT current transformers CT n Current transformers (CT) Technical characteristics Degree of protection: IP 0 Operating frequency: 50/60 Hz Pack Cat.Nos Single-phase current transformers (CT) Used with ammeters, electricity meters or multi-function measuring units Providea0to5Acurrentatthesecondary, proportional to the primary current For fixing on plates, EN rail Cat.Nos /4/6, or bars Secondary connected by terminals or lugs Precision class % For6x.5mmbarandØmmcable Transformation ratio Output (VA) / / /5 5.5 For 0.5 x.5 and 0 x 0.5 mm bar and Ømmcable /5 For40.5x0.5mmbarandØ5mmcable /5 For 65 x mm bar / / /5 0 For 84 x 4 mm bar /5 5 For 7 x 8 mm bar / /5 0 For 7 x 54 mm bar / /5 50 Three-phase current transformers (CT) Used with ammeters, electricity meters or multi-function measuring units Providea0to5Acurrentatthesecondary, proportional to the primary current For fixing directly on bars Secondary connected by terminals or lugs Precision class % For three 0.5 x 5.5 mm bars Transformation ratio Output (VA) /5 For three 0.5 x 5.5 mm bars /5 4 Dimensions Single-phase CTs Cat.Nos /4/6 for 6 x.5 mm bar and Ø mm cable Fixing on EN 6075 rail ,5 65 Cat.No for 0.5 x.5 and 0 x 0.5 mm bar and Ø mm cable Cat.No 00468for40.5x0.5 mmbarandø5mmcable Fixing on EN 6075 rail or on plate Cat.Nos A B C D Ø Fixing centres on plate x x 45 Cat.Nos /77/78 for 65 x mm bar Cat.No for 84 x 4 mm bar Fixing on bar Cat.Nos A B C D /77/ Cat.Nos /46 for 7 x 8 mm bar Cat.Nos and for 7 x 54 mm bar Fixing on bar Cat.Nos A B / / Three-phase CT Cat.No for three 0.5 x 5.5 mm bars Cat.No for three 0.5 x 5.5 mm bars Fixing on bar 56 D C D B A A B C 45 A A 87 B C B Cat.Nos A B C Determination of the max. distance between CT and meter Cat.Nos Max. power Meter Max. distance bet. CT & meter (m) of CT consump. Max. loss in (W) capac. (VA) Wiring Wiring Wiring.5 mm 4mm 6mm /
17 EMDX electrical energy meters 4 rail mounting ntechnical characteristics Single-phase meters Cat.Nos /7/77/78/79/8 LCD display: 7 digits Resolution: 0. kwh Maximum indication: kwh Metrological LED: Wh/pulse (Cat.No : 0.5 Wh/pulse) Accuracy (EN 605-): class Reference voltage Un: 0 V-40 V Reference frequency: Hz Pulse output: pulse/0 Wh (Cat.No : pulse/wh) Three-phase meters Cat.Nos /74/80/8/8/84/85/86 LCD display: 8 digits Resolution: 0.0 kwh () Maximum indication: kwh () Metrological LED: 0. Wh/pulse or Wh/pulse Active energy accuracy (EN 605-): class Reactive energy accuracy (EN 605-): class Reference voltage Un: - Single-phase: 0-40 V - Three-phase: 0(400)-40(45) V Operating limit range (EN 605-, EN 605-): - Single-phase: 0 to 54 V - Three-phase: 0(90) to 54(440) V Pulse output: pulse/0 Wh Cat.Nos Number of modules Connection Direct Via a current transformer Single-phase Three-phase Max. current A 6 A 6 A 6 A 6 A 6 A 6 A 6 A 6 A 6 A 5 A (CT) Metering and measurement Communication MID compliant Operating conditions Total active energy Total reactive energy Partial active energy (reset) Partial reactive energy (reset) Active power Reactive power Apparent power Current Voltage Frequency Power factor Time-of-use Average active power Max. average active power value Dual tariff Pulse output RS 485 interface Reference temperature C ± C Operating temperature -0 to +55 C -0 to +45 C -5 to +55 C Storage temperature -40 to +70 C -5 to +70 C -5 to +70 C Consumption 8 VA 4 VA per phase VA per phase Heat dissipation 6.5 W 6W 4W 5A (CT) 5A (CT) 5A (CT) n Interfacing with IP communication network Pulse electricity meters RS 485 electricity meters Concentrator Cat.No Connects up to 7 pulse electricity meters RS Fieldbus RS485/IPconverter Cat.No IP network - Communication bus : For direct connection meters If connected via transformers, the resolution and maximum indication depend on the transformation ratios of these transformers 5
18 EMDX multi-function measuring units n Technical characteristics Cat.Nos / Connection Current measurement terminals 4mm 6mm 6mm Other terminals.5 mm.5 mm.5 mm Protection index Front cover IP5 IP5 IP5 Casing IP0 IP0 IP0 Weight 05/5 g 400 g 400 g Display Backlit LCD Backlit LCD Backlit LCD Measurements P+N, P, P, P+N P+N, P, P, P+N P+N, P, P, P+N Voltage measurement Current measurement Power measurement Frequency measurement Direct From a PT Phase/phase 50 to 50 VA 50 to 500 VA 8 to 700 VA Phase/neutral 8 to 00 VA 8 to 89 VA to 404 VA Primary kv Secondary , 00, 0, 5, 0, 7, 90 VA Permanent overload between phases 760 VA 800 VA 760 VA Update period s s s From a CT Primary 5to9999A 9999 A 9995 A Secondary 5 A 5 A or 5 A Minimum measurement 5 ma 5 ma 0 ma Input consumption < 0.6 VA < 0.6 VA < 0. VA Display 0 to 9999 A to ka 0 to ka Permanent overload 6A 6A 0 A Intermittent overload 60 A/ s - 0 A/0.5 s 0 In/ s 0 In/ s Update period s s s Max. CT x PT ratio Total 0 to 9999 kw/kvar/kva 0 to MW/Mvar/MVA 0 to 8000 MW/Mvar/MVA Update period s s s Measurement range 45.0 to 65.0 Hz 45.0 to 65.0 Hz 45.0 to 65.0 Hz Update period s s s 50/60 Hz 00 to 77 VA ±5% 0 to 400 VA ±0% 0 to 400 VA ±0% Auxiliary power supply DC - 0 to 50 V= ±0% 0 to 50 V= ±0% Consumption <5VA <0VA <0VA Operating temperature -0 C to +55 C -0 C to +55 C -0 C to +55 C Storage temperature -0 C to +70 C -0 C to +85 C -0 C to +85 C n Flush-mounting dimensions Cat.Nos /69 n Fixing on door Cat.Nos / ,8-0, ,8-0, n Fitting modules Cat.Nos /69 6
19 n Connection solutions n Wiring example of communication network Unbalanced three-phase network ( or 4-wire) I I I S S S S S S V V V VN AUX Measure Software unlimited S P S P S P (-wire) L (R) L (S) L (T) N Web server Cat.Nos /79 IP protocol - Ethernet BUS Legrand software Cat.Nos /89 I I I S S S S S S V V V VN AUX I I I S S S S S S V V V VN AUX IP converter RS485/IP Cat.No S P S P L (R) L (S) L (T) S P S P L (R) L (S) L (T) Energy meters Cat.No Balanced three-phase network ( or 4-wire) I I I S S S S S S V V V VN AUX RS 485 fieldbus Multi-function measuring unit Cat.No S P L (R) L (S) L (T) N Single-phase network (-wire) Two-phase network (-wire) I I I S S S S S S V V V VN AUX I I I S S S S S S V V V VN AUX EDMX Access multi-function measuring unit Cat.No Communication module Cat.No S P L (R) N S P L (R) L (S) a Auxiliary power supply: VAC/0 50 VDC b Fuse: 0.5 A gg/bs 88 A gg/0.5 A class CC EDMX Premium multi-function measuring unit Cat.No Communication module Cat.No
20 EXB049 - July 0 - Photos: Istock - Pierre Maufront World Headquarters and International Department 8, av. du Maréchal-de-Lattre-de-Tassigny Limoges CEDEX France % :+(0) Fax: + (0)
DIRIS A40 Multifunction meters - PMD Multi-measurement meter - dimensions 3.78 x 3.78 in/96 x 96 mm
Single-circuit metering, measurement & analysis The solution for > Industry > Data centres > Infrastructures Function are panel mounted measurement units which ensure the user has access to all the measurements
More informationEnergy counting and measurement
Energy counting In the current context of research of energy saving, counting of consumption become unavoidable. Hager offers new residential and tertiary solutions, to better control energy consumption.
More informationDIRIS A40/A41 Multifunction meters - PMD multi-measurement meter - dimensions 96 x 96 mm
Single-circuit metering, measurement & analysis The solution for > Industry > Data centres > Infrastructures DIRIS A4 Function and A4are panel mounted measurement units which ensure the user has access
More informationDIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis
diris_561_b_3_x_cat 1 1. Backlit LCD display. 2. Direct access key for currents and setup wiring correction. 3. Direct access key for voltages and frequency. 4. Direct access key for active, reactive,
More informationRI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current
More information3-phase meter with direct connection and pulse or Modbus RS485 output
87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 3-phase meter with direct connection and CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...
More informationApplications. diris_581_d_1_gb_cat. Multimeasurement. Currents
Measurement units EW Applications Ethernet diris_744_a_1_cat PC Main meter panel diris_581_d_1_gb_cat COTROL VISIO software Currents per phase curve appli_384_b Monitoring and managing energy for high/low
More informationData Sheet. RISH Master Record %THD
Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy
More information Applications DIRIS A40 DIRIS A40 DIRIS A40. diris_581_e_1_gb_cat
Multifunction meters EW  Applications DIRIS A4 Ethernet diris_744_a cat PC Main meter panel Monitoring and managing energy for high/low voltage electrical installations  Function The and A4 are multifunction
More informationApplications. diris_581_e_1_gb_cat
Multifunction meters EW Applications Ethernet diris_744_a_1_cat PC Main meter panel Monitoring and managing energy for high/low voltage electrical installations Function The and A41 are multifunction meters
More informationEnergy Measurement & Management
Energy Measurement & Management Countis kwh Meters Diris Multifunction Meters Software Installation Solutions IPD Industrial Products is an Australian owned leading distributor of a wide variety of low
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More informationRISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:
Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationRISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:
(With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network
More informationEnergy Management Energy Meter with plug-in Output Modules Type EM4-DIN
Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse
More informationPower Meter Series PM3200 Functions and characteristics
Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring
More informationDigital Multifunction Instrument - Rish Master 3440
Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationRISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:
Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit
More informationEnergy Management Three-phase energy meter with output modules Type EM4-DIN
Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT
More informationMT 560/UMT TRANSDUCER & ANALYZER
MT 560/UMT 560 - TRANSDUCER & ANALYZER USE The MT 560/UMT 560 multi transducer and analyzer is used for a permanent analysis of electricity supply quality in compliance with the SIST EN 50160 standard.
More informationSingle phase meter with direct connection and pulse or Modbus RS485 output
87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 Fax: +33(0)5 55 06 88 88 Single phase meter with direct connection CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...
More informationActi 9 Energy Meters. iem3000 Series. Technical data sheet
Acti 9 Energy Meters iem3000 Series Technical data sheet 1 PB108410 b The Acti 9 iem3000 Energy Meter Series offers a cost-attractive, competitive range of DIN rail-mounted energy meters ideal for sub-billing
More informationRISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters
measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy
More informationALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More information1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus
speicher MID energy meter ECSEM series Emax 2 Tariffs GridVis 7 Tariffs 8 Tariffs 14 Tariffs 0,2 kwh Class 0,5 kwh Class 1,0 kwh Class Pulse output Tarife 2 tariffs Messgenauigkeit Modbus MID M-Bus eratureingang
More informationMonitoring Electric Network Via Internet
Monitoring Electric Network Via Internet NETWORK ANALYSER let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording
More informationActi 9 Energy Meters. iem3000 Series. Technical data sheet
Acti 9 Energy Meters iem3000 Series Technical data sheet PB108410 b The Acti 9 iem3000 Energy Meter Series offers a cost-attractive, competitive range of DIN rail-mounted energy meters ideal for sub-billing
More informationTechnical Data Sheet AMIK 300 / 301
USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important
More informationPowerLogic power-monitoring units. PM700 series power meter. Technical data sheet
PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required
More informationRI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA
More informationUNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49
TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact
More informationMICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2
PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features
More informationMultifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port
Viale Borri 231, 21100 Varese Italy Multifuncion Measuring Device, 4 mod. Contents Pages 1. Description Use... 2 2. Range... 2 3. Overall dimensions... 2 4. Preparation Connection... 2 5. General characteristics...
More informationEM-72 Electricity Meters for Current Transformers
Product sheet MT8.18 Meter EM72 EM-72 Electricity Meters for Current Transformers EM72 electricty meters have been designed for panel mounting to monitor electricity consumption and the quality of the
More informationTechnical Data Sheet. x1000. kwh R Y B
Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy
More informationElectrical network management. Schneider Electric. PM3200 Technical Datasheet
Electrical network management Schneider Electric PM3200 Technical Datasheet Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact
More informationRISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics
Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock
More informationPRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID
RIF300 Series easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer input with TASSCTEWA module)
More informationDIRIS. The multi-function multi-measurement range MADE TO MEASURE
DIRIS A The multi-function multi-measurement range for managing YOUR ELECTRICAL NETWORKS MADE TO MEASURE DIRIS system: the reference Measurement is the key link in managing an energy efficiency project.
More informationActi 9 Energy Meters. iem3000 Series. Technical data sheet
Acti 9 Energy Meters iem3000 Series Technical data sheet 1 PB108410 b The Acti 9 iem3000 Energy Meter Series offers a cost-attractive, competitive range of DIN rail-mounted energy meters ideal for sub-billing
More informationCOUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet
INSTRUCTION MANUAL COUNTIS E27/E28 Three-phase energy meter Direct - 80 A Ethernet EN countis e27 countis e28 - mid www.socomec.com/ en/countis-e2x EN Contents 1. Documentation.... 3 2. Hazards and warnings...
More informationSHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100
APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationEnergy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302
Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters
More informationEnergy Management Energy Analyzer Type EM210 MID
Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3
More informationHV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point
2010 MAP Range HV / MV / LV electrical network quality analyzers Class A > Network quality Analyzers PRODUCT ADVANTAGES COMPLIANT with the EN 61000-4-30 standard, Class A DETECTION of the fault LOCATION
More informationMultifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port
87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax: 05 55 06 88 88 Multifuncion Measuring Device, 4 mod. Contents Pages 1. Description Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...
More informationRUDOLF Digital power analyzer. Advanced Version
RUDOLF Digital power analyzer Advanced Version Digital power analyzer Advanced Version Company Introduction Bridex Singapore Pte Ltd is founded in 1978 as a manufacturer of instruments transformer for
More informationMID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID
Telephone : 44 (0) 1245 428500 RIF300 Series MID easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 1A Input from easywire CTs Single phase or three phase network
More informationnd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485
cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase
More informationMID. Energy Management Energy Analyzer Type EM Product Description. How to order EM26 96 AV5 3 H O3 S1 PF A. Type Selection EM26 96
Energy Management Energy Analyzer Type EM26 96 M-bus communication by means of VMU-B adapter Application adaptable display and programming procedure (Easyprog function) Easy connections management Certified
More informationnew! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS
new! cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement of power network parameters in 3- or 4-wire balanced and unbalanced systems. Color graphic display: lcd TFT 3,5, 320
More informationPRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter
Telephone : 44 (0) 1245 428500 PRELIMIARY DATA SHEET RIF400 Series easywire Single and Three Phase Multifunction Energy Meter DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer
More informationSHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2
APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the
More informationENERIUM. A powerful solution for energy management and the environment
ENERIUM A powerful solution for energy management and the environment Sustainable development A responsible commitment Vital for the production of all the products and services we consume, electricity
More informationCentrale de mesure Power Meter PM500 Merlin Gerin
Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with
More information3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3
More informationM.3. Electrical measurement and control. Electrical energy meters for partial consumption
M.3 Electrical measurement and control Electrical energy meters for partial consumption M.3 Electrical energy meters for partial consumption M.3 - Electrical energy meters for partial consumption Introduction
More informationSmart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)
Smart Energy & Power Quality Solutions UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC) UMG 96RM UMG 96RM Universal measurement instrument Unrivalled in its class The UMG 96RM is a
More informationCOUNTIS E23. Three-phase energy meter Direct - 80 A MODBUS. Instruction manual. en/countis-e2x
Instruction manual COUNTIS E23/E24 Three-phase energy meter Direct - 80 A MODBUS COUNTIS E23 COUNTIS E24 - MID www.socomec.com/ en/countis-e2x Contents 1. Documentation.... 3 2. Hazards and warnings...
More informationCOUNTIS and DIRIS systems CONTROL AND ENERGY MANAGEMENT FOR ELECTRICAL NETWORK INSTALLATIONS
COUNTIS and DIRIS systems CONTROL AND ENERGY MANAGEMENT FOR ELECTRICAL NETWORK INSTALLATIONS SOCOMEC GROUP SWITCHING PROTECTION & UPS Industrial Switching & Protection Systems COUNTIS and DIRIS systems:
More informationPower quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I
Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th
More informationApplication Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters
Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel
More informationTechnical Data Sheet
Technical Data Sheet parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters. Special Features Pulse/Limit Switch output (optional) Number of interruption Application
More informationPower analyzers and Energy Meters Power Analyzer Type WM14-DIN
Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationPower analyzers and Energy Meters Power Analyzer Type WM14-96
Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)
More informationPower analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.
Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase
More informationEnergy Management Modular Power Analyzers Type WM2-96
ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer
More informationKE-N80. Item: kg/pc unit Item No. KE-N80 three phase Energy Meter for direct connection 80A 0, DIN rail 35mm
WE CONNECT TO PROTECT K electric GmbH Carl-Benz-Str. 7 D 95448 Bayreuth Fon +49 (0) 921 1512678-0 Fa +49 (0) 921 1512678-20 E-mail: office@k-electric-gmbh.de www.k-electric-gmbh.de DIN rail 35mm KE-N80
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationEnergy Management Energy Meter Type EM112
Energy Management Energy Meter Type EM112 Easy connection or wrong current direction detection Other versions available (not certified, option X: see how to order on the next page Single phase energy meter
More informationMoving Test - MT3000
Moving Test - MT3000 Three-Phase Portable Test System Keep ahead with Modular Design The Modular Concept The MT3000 is based on a real modular design concept to provide the greatest possible flexibility
More informationEnergy Management Power Analyzer with plug-in Output Modules Type W M22-DIN
Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Front dimensions: 9 DIN modules Analogue output by means of optional module (20mA or 10VDC) RS 422/485 Serial port by means of
More informationContents. Introduction and description Package contents Device identification PM Options... 80
Contents 1 Introduction and description Package contents... 77 Device identification... 77 2 Characteristics PM500... 78 Options... 80 3 Installation Front-panel cut-out... 82 Mounting... 82 4 Connections
More informationMID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN
Energy Management Energy Meter Type EM33 DIN Easy connections management Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X):
More informationEnergy Management. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X. Type Selection. Input specifications
Energy Management Multifunction indicator Type WM12-DI Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase measurements:
More informationSHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2
APPLICATION ultrasonic compact energy meter can be used for measuring the energy consumption in heating / cooling application for billing purposes. The measurement principle is static and based on the
More informationINTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]
Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High
More informationEnergy Management Energy Meter Type EM21 72R Retro-Fit
Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class
More informationBrunata Optuna H. Properties. Counter
Brunata Optuna H Brunata Optuna H measures energy consumption in large and small heating and cooling systems as well as combined heating and cooling systems. The meter is compact and belongs to the first
More informationDimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung
Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply
More informationPower IT LV Active Filters PQFA - PQFL - PQFT
Power IT LV Active Filters PQFA - PQFL - PQFT The ABB comprehensive solution for active filtering of harmonics Pst Harmonics and Power Quality Harmonics caused by non-linear electrical loads such as variable
More information400,440Vac Vdc V, A, W, VA, var, Hz, V, Avg. A cos phi, sin phi and phi measurement kwh, kvarh (via Pulse Output)
MODEL EM4000ACF Multifunction Transducer for alternating voltage and current Power supply voltages: Suitable for DIN-rail mounting 85 240Vac 400,440Vac 24 65Vdc 100..330Vdc V, A, W, VA, var, Hz, V, Avg.
More informationMID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN
Energy Management Energy Meter Type EM23 DIN Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X): see how to order on the next
More informationPower factor correction and harmonic filtering. Automatic power factor regulators R.1
Power factor correction and harmonic filtering Automatic power factor regulators R.1 R.1 Automatic power factor regulators R.1 - Automatic power factor regulators Selection table R1-4 computer Plus-T Intelligent
More informationEnergy Management Energy Meter Type EM111
Energy Management Energy Meter Type EM111 Easy connection or wrong current direction detection Other versions available (not certified, option X: see how to order on the next page Single phase energy meter
More informationNETWORK ANALYZERS Analyzers
CONTENTS PRODUCTS RANGE NA.03 NETWORK ANALYZER - LCC NETWORK ANALYZER - LCA NETWORK ANALYZER - LDA NETWORK ANALYZER - LAB96 NETWORK ANALYZER - LABM NA.04 NA.06 NA.09 NA.10 NA.13 NETWORK ANALYZER - LCCM
More informationIntroduction DIN rail mounted electricity meters
Introduction DIN rail mounted electricity meters Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail
More informationApplication: Product Features: On site programmable PT/CT ratios: User selectable CT Secondary 5A/1A. User selectable PT Secondary
Application: Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwor & replaces the multiple analog panel meters. t measures electrical parameters lie AC current,, frequency,
More informationENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake
ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate
More informationEnergy Management Energy Meter Type EM340
Energy Management Energy Meter Type EM340 Digital input (for tariff management Easy connection or wrong current direction detection Certified according to MID Directive (option PF only: see how to order
More information12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices
BETA Measuring /2 Product overview /3 7KT1 14, 7KT1 53 E-counters /9 7KT1 11, 7KT1 digital measuring devices /11 7KT1 0 analog measuring devices / 7KT5 8 time and pulse counters /14 7KT5 5, 7KT5 6 time
More informationULTRA RAPID POWER QUALITY ANALYZER
ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with
More informationUPM209 1/5A CT, 80A Multifunction three-phase meter
1/5A CT, 80A Multifunction three-phase meter 4 DIN modules compact version Fully bi-directional four quadrants measurements for all energies and powers Main electrical parameters measured and displayed
More informationFluke Fluke-Direct.ca. Three-Phase Power Logger. Technical Data
Fluke 1735 Three-Phase Power Logger Technical Data Electrical load studies, energy consumption testing, and general power quality logging The Fluke 1735 Three-Phase Power Logger is the ideal electrician
More informationnd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS
nd30pnet tri Measurement of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems. graphical color display:
More informationModel Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.
Power analyzers and Energy Meters Multifunction indicator Type WM12-96 Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase
More informationEnergy Management. Type WM14-96 Basic Version. Product Description. How to order WM14-96 AV5 3 D PGX. Type Selection. Input specifications.
Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer
More information