Monitoring Electric Network Via Internet
|
|
- Dwayne Bond
- 5 years ago
- Views:
Transcription
1 Monitoring Electric Network Via Internet NETWORK ANALYSER
2 let "it" analyse! MPR63 Real time monitoring via internet / intranet Measurement of all electrical parameters Including Harmonics Automatic recording into internal memory Programmable alarm outputs RS-485, MODBUS / PROFIBUS Communication and SCADA compatibility. Energy Billing & consumption reports with 4 tarrifs Text & graphic reports between determined dates Compensation report Helps to SAVE ENERGY
3 NETWORK ANALYSER Server internet / intranet Client Client Client monitoring electric network via internet
4 DIGITAL NETWORK ANALYSER MPR-63 / MPR-60S GENERAL MPR-63 / 60S are designed for measuring all electrical parameters, including harmonics, of an electric network with MODBUS-RTU protocol on RS-485 communication port. 1. MPR-63 / MPR63-10 : Digital network analyser with harmonic measurement (THD V%, THD I%, up to 31th harmonic for current and voltage separately.) Digital input / output for MPR MPR-60S / MPR60S-10 : Digital network analyser with total harmonic measurement (THD V%, THD I%) Digital input / output for MPR60S-10 RS-USB2 MPR-63 (Max. 247 devices) FEATURES Measuring up to 31th Harmonic for current and voltage separately. (Only for MPR-63) Total Harmonic Distortion for (THD V%) Total Harmonic Distortion for (THD I%) RS-485 Communication. Neutral Alarm Contact Output or Digital Output. Energy Pulse Output or Digital Input (optional) ma Analog Output for PLC s or other auxiliary tracking methods (optional). Display Demand Value. Display Max/Min Values. Parameters and demand values are stored even if supply voltage is cut off. Data Logging. (1 MB Internal Memory) Real Time Clock. Non-flammable enclosure. Password Protection for Setup. IEC , IEC , IEC Software : Software for monitoring and recording parameters for MPR and EPR Series. Rail-Mount Kit Wall-Mount Kit ORDER NO. MPR-60S MPR60S-10 MPR-63 MPR63-10 % Harmonise Converter (RS-USB2) / Repeater (RPT-1) USB Converter (RS-USB2) : RS-485 / USB Converter for communicating PC with MPR and EPR Series. Repeater (RPT-1): Amplifies the communication data signal. 1 RPT-1 must be used for each 20 devices. RS 485 / USB Harmonic Graphic which belongs to the same phase up to 31th harmonic. Measured Parameters 2nd, 3rd, 4th... 31th Harmonic for I and V. Phase - Neutral s (V LN) Phase - Phase s (V LL) Average Phase - Neutral Average Phase - Phase Phase s (I) Neutral Total ( I) Power Factor (P.F) Cos Frequency (Hz) Max., Min. and Demand Values Active Power (P) Reactive Power (Q) Apparent Power (S) Total Active Power ( P) Total Reactive Power ( Q) Total Apparent Power ( S) Active Energy - Import (kwh) Active Energy - Export (kwh) Reactive Energy - Capacitive (kvarh) Reactive Energy - Inductive (kvarh) Total Harmonic Distortion for (THD V %) Total Harmonic Distortion for (THD I %) DESCRIPTION Digital Network Analyser with LCD Display (96x96mm) Digital Network Analyser with LCD Display + Digital Input and Digital Output (96x96mm) Digital Network Analyser with LCD Display (96x96mm) Digital Network Analyser with LCD Display + Digital Input and Digital Output (96x96mm) MPR-63 / MPR63-10 : THD V%, THD I%, up to 31th harmonic for current and voltage separately. Digital Output Digital Input (only for MPR63-10) MPR-60S / MPR60S-10 : THD V%, THD I% - Digital Output - Digital Input (only for MPR60S-10)
5 DIGITAL NETWORK ANALYSER MPR-63 / MPR-60S MODEL Digital Output MPR-63 MPR63-10 MPR-60S SPECIFICATIONS Electrical Parameters Harmonic Measurement 2-31th separately voltage & current THD V%, THD I% THD V%, THD I% Operating 230 V AC * ± 10% ; 50/60 Hz Network Type 3-phase / 4-wire (Star) ; 3-phase / 3-wire (Delta) ; 3-phase / 3-wire (Aron) Accuracy Frequency Active Power Reactive Power Transformer Ratio Transformer Ratio Measurement input Measurement Ranges Frequency Power Energy Power Consumption Burden Demand Time Communication Interface Baud Rate / Adress / Parity Alarm Contact Digital Inputs Functions Input Pulse Width Operation 0,5 % ± 2 digit 0,5 % ± 2 digit 0,1 % ± 2 digit 1 % ± 2 digit 2 % ± 2 digit (programmable) 1, ,0 (programmable) 1,0-300,0 V AC (L-N), 2,0-500,0 V AC (L-L) 5 ma - 5,5 A 1,0-400,0 kv 5 ma A 45,0-65,0 Hz M (W, VAr, VA) kwh, kvarh < 6 VA < 1 VA ( burden), < 0,5 VA ( burden) 1-60 min. (programmable) MODBUS RTU (RS-485) bps / / None, Odd, Even Output 1 / Output 2 : 2 NO Relay ; 5 A,1.250 VA (resistive) Real Time / Latch 50 msec. (Min.) VDC, 30VDC (Max.) MPR60S-10 Real Time / Latch 50 msec. (Min.) VDC, 30VDC (Max.) Energy Pulse Output Output 3: Active Energy Pulse Output (1kWh...50 MWh / pulse) - NPN Transistor Output 4: Reactive Energy Pulse Output ( 1kVArh...50 MVArh/pulse)-NPN Transistor Output 3: Active Energy Pulse Output (1kWh...50 MWh / pulse) - NPN Transistor Output 4: Reactive Energy Pulse Output ( 1kVArh...50 MVArh/pulse)-NPN Transistor Switch Period Operation Operation Analog Output (optional) Display Data Logging Memory Min. 1 sec. ( msec. pulse width) Max. 50 ma 5 24 V DC, max. 30 V DC 4-20 ma 3,6 LCD with Backlight, 12 mm Height Selectable 28 parameters with Time Stamp ( records) 1 MB Internal Memory Min. 1 sec. ( msec. pulse width) Max. 50 ma 5 24 V DC, max. 30 V DC Mechanical Parameters Equipment Protection Ambient Operating Temperature Degree of Protection Connection / Installation Dimensions Weight / each Quantity in 1 package Double Insulation ( ), Measurement Category III -5 o C, +55 o C IP40 (front panel) Terminal / Flush-mounting with rear terminals 96x96 mm (PR19**) 0,9 kg 8 pcs * Different operating voltages are available upon request. Please notify VOLTAGE ( ) with the order.
6 DIGITAL NETWORK ANALYSER MPR-53 Series GENERAL MPR-53 Series measure all parameters of an electric system. More than 50 parameters are displayed. 1. MPR-53 : Network Analyser with pulse output. 2. MPR-53S : Network Analyser with RS-485 PC communication (MODBUS-RTU protocol) and pulse output. IEC , IEC , IEC Software : Software for monitoring and saving parameters for MPR and EPR Series. RS-USB2 MPR-53S-96 (Max. 247 devices) Converter (RS-USB2) / Repeater (RPT-1) USB Converter (RS-USB2) : RS-485 / USB Converter for communicating PC with MPR and EPR Series. Repeater (RPT-1): Amplifies the communication data signal. 1 pc RPT-1 must be used for each 20 devices. Rail-Mount Kit Phase Displays Average Display Total Display Average Up Down Max. LED Demand Min.LED Demand LED Total RS 485 / USB MPR-53S-144 Wall-Mount Kit MPR-53S-DIN Measured Parameters : Phase - Neutral s (VLN) Phase - Phase s (VLL) Average Phase - Neutral Average Phase - Phase Phase s (I) Total ( I) Power Factor (P.F) Frequency (Hz) Active Power (P) Max. And Min. Demand Values Reactive Power (Q) Apparent Power (S) Total Active Power ( P) Total Reactive Power ( Q) Total Apparent Power ( S) Active Energy - Import (kwh) Active Energy - Export (kwh) Reactive Energy - Capacitive (kvarh) Reactive Energy - Inductive (kvarh) Non-flammable enclosure ORDER NO DESCRIPTION MPR Network Analyser (96x96 mm) MPR Network Analyser (144x144 mm) MPR-53-DIN- Network Analyser ( DIN 6 (Pk26)) MPR-53S -96- Network Analyser with RS-485 communication (96x96 mm) MPR-53S Network Analyser with RS-485 communication (144x144 mm) MPR-53S -DIN- Network Analyser with RS-485 communication (DIN 6 (PK26)
7 DIGITAL NETWORK ANALYSER MPR-53 Series MODELS SPECIFICATIONS Functions RS-485 Communication Energy Pulse Output Display Demand Value Display Max/Min Values Password Protection Electrical Parameters Operating Network Type Accuracy Transformer Primary Value Transformer Ratio Measurement input Measurement Ranges Frequency Power Factor Power Energy Power Consumption Burden Demand Time Communication Interface Baud Rate Address Parity Energy Pulse Output Switch Period Operation Operation Display Mechanical Parameters Equipment Protection Ambient Operating Temperature Degree of Protection Connection / Installation Dimensions Weight / each Quantity in 1 package MPR-53 3-phase / 4-wire (Star) 3-phase / 3-wire (Delta) 3-phase / 3-wire (Aron) 1% ±1 digit / 5 A (programmable) < 4 VA MODBUS RTU (RS-485) No, odd, even Min. 1,6 sec. (400 msec. pulse width) Double Insulation ( 230 V AC * ±10%; 50 / 60 Hz (programmable) V AC (L-N), V AC (L-L) 50 ma - 5,5 A 4 quadrant M (W, VAr, VA) ,999 kwh, kvarh 1-60 min. (programmable) bps NPN Transistor Max. 50 ma 5 24 V DC, max. 30 V DC Red LED ; 10 mm Height o IP40 (front panel) Terminal / Flush-mounting with rear terminals 4 pcs (PR16) ; 12 pcs (PR19), 12 pcs (DIN6) MPR-53S V (direct), kv (with voltage transformer) 50 ma - 5,5 A (direct), 50 ma A (with current transformer) Hz < 1 VA ( burden), < 0,5 VA ( burden) ), Measurement Category III 144x144 mm (PR16**) ; 96x96 mm (PR19**), DIN6 (PK26**) o -5 C, +55 C 0,8 kg (PR16) ; 0,6 kg (PR19) ; 0,6 kg (DIN6) * Different operating voltages are available upon request. Please notify VOLTAGE ( ) with the order.
8 Chennai LVR CENTRE, 3rd Floor No. 7, Seshadri Road, Alwarpet, Chennai Tel. : , Mobile : Fax : chennai@bchindia.com Surat 601/A, 21st Century Business Centre Ring Road Surat Mobile : surat@bchindia.com Salem Vadodara 101, Toran Complex, Vikas Nagar Old Padra Road Vadodara Tel. : baroda@bchindia.com Western UP & Uttarakhand 8, Cooperative Industrial Estate Patel Nagar Dehradun : Uttarakhand Mobile : dehradun@bchindia.com
NETWORK ANALYSER MPR-50 / MPR-52S / MPR-60S / MPR-63
ETWOR AAYSER MPR-50 / MPR-52S / MPR-60S / Modbus / Ethernet Gateway Genera MPR-50 : etwor Anayser. MPR-52S : etwor Anayser with THD measurement, R S-45 (MODBUS) and Aarm Contact. MPR-60S: etwor Anayser
More informationRI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current
More informationRISH PQM. Power Quality Monitor. Preliminary Datasheet subject to change without notice. Individual Harmonics measurement upto 56th Harmonics
Power Quality Monitor Individual Harmonics measurement upto 56th Harmonics True representation of Voltage & Current waveforms. Phasor Representation of All 3 phases for system analysis Real Time Clock
More informationINTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]
Feature Suit for LV/ HV voltage system Compact design with all real-time measurement Consist of basic unit and optional modules 10 years back-up of integrated energy data Large LCD, high brightness High
More informationN100. example of application Ethernet www/ ftp. Ethernet TCP IP RS X MeaSUreMent of power network parameters.
cat iii Electrical Safety N100 - power network analyzer Measurement of power network parameters in 3 or 4-wire, balanced or unbalanced systems. two-color led display (red, green). Four quadrant energy
More informationRI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters
RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA
More informationPRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID
RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A
More informationPEM353. Universal measuring device
353 Universal measuring device 353_D00335_00_D_XXEN/06.2018 353 Universal measuring device Product description The digital universal measuring device 353 is used to record and display measured quantities
More informationPower analyzers and Energy Meters Power Analyzer Type WM14-DIN
Power analyzers and Energy Meters Power Analyzer Type WM14-DIN Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)
More informationUNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49
TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact
More informationnew! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS
new! cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement of power network parameters in 3- or 4-wire balanced and unbalanced systems. Color graphic display: lcd TFT 3,5, 320
More informationEM-72 Electricity Meters for Current Transformers
Product sheet MT8.18 Meter EM72 EM-72 Electricity Meters for Current Transformers EM72 electricty meters have been designed for panel mounting to monitor electricity consumption and the quality of the
More informationMICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2
PART 1 PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eaton products B.. C.. The listing of specific manufacturers above does not imply acceptance of their products that do not meet the specified ratings, features
More informationData Sheet. RISH Master Record %THD
Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy
More informationPower analyzers and Energy Meters Power Analyzer Type WM14-96
Power analyzers and Energy Meters Power Analyzer Type WM14-96 Optional RS422/485 serial port Alarms (visual only) V LN, An Class 2 (active energy) Class 3 (reactive energy) Accuracy ±0.5 F.S. (current/voltage)
More informationALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationnd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485
cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase
More informationPRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter
Telephone : 44 (0) 1245 428500 PRELIMIARY DATA SHEET RIF400 Series easywire Single and Three Phase Multifunction Energy Meter DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer
More informationEnergy Management. Type WM14 DIN Advanced version. Product Description 3-phase advanced power analyzer with integrated programming
Energy Management Type WM14 DI version Protection degree (front): IP40 2 digital outputs 16 freely configurable alarms with OR/AD logic linkable with up to 2 digital outputs RS422/485 serial output (MODBUS-RTU),
More informationPRELIMINARY DATA SHEET. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID
RIF300 Series easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer input with TASSCTEWA module)
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationULTRA RAPID POWER QUALITY ANALYZER
ULTRA RAPID POWER QUALITY ANALYZER Ultra rapid (cycle by cycle) advanced electrical network analysis Complete network harmonics analysis, up to 63 rd harmonic High visibility, 5 graphic LCD screen with
More informationPower Meter Series PM3200 Functions and characteristics
Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring
More informationDIRIS A40 DIRIS A41. Functions. Conformity to standards. Applications. Energy management DIRIS A40. Network analysis
diris_561_b_3_x_cat 1 1. Backlit LCD display. 2. Direct access key for currents and setup wiring correction. 3. Direct access key for voltages and frequency. 4. Direct access key for active, reactive,
More informationnd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS
nd30pnet tri Measurement of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems. graphical color display:
More informationALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More informationENGLISH 3 Phase Multi-function Power Meter 1/5A MID MID
Professionally approved products. Datasheet Stock Number: 144-0527 3 Phase Multi-function Power Meter 1/5A MID 96mm² Panel Mounted Power Meter. MID UK Specifications The 144-0527 is a new generation modern
More informationCROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM
CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM The Crompton Instruments INTEGRA 1222 digital metering system (dms) from TE Connectivity enables cost effective solution for the measurement and
More informationRISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:
Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationPLA 33. Power line analyzer. User and service manual. version 2.4
PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0
More informationPower quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I
Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th
More informationRTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03
Multimeter 560CVD03 Without LCD Display There are several versions available: With LCD Display Figure 1 Type Display LO HI 1A 5A Versions R0031 3U3I x x x R0035 3U3I x x x R0051 3U3I x x x R0055 3U3I x
More informationEnergy Management Three-phase energy meter with output modules Type EM4-DIN
Energy Management Three-phase energy meter with output modules Type EM4-DIN Class 1 (active energy) Class 2 (reactive energy) Three-phase multi-function energy meter Back-lighted LCD display 3 1 / 2 DGT
More informationMID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID
Telephone : 44 (0) 1245 428500 RIF300 Series MID easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 1A Input from easywire CTs Single phase or three phase network
More informationMT 560/UMT TRANSDUCER & ANALYZER
MT 560/UMT 560 - TRANSDUCER & ANALYZER USE The MT 560/UMT 560 multi transducer and analyzer is used for a permanent analysis of electricity supply quality in compliance with the SIST EN 50160 standard.
More informationENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake
ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate
More informationPower analyzers and Energy Meters. Multifunction indicator. Type WM12-DIN. Product Description. How to order WM12-DIN AV5 3 D X.
Power analyzers and Energy Meters Multifunction indicator Type WM12-DIN Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase
More informationEASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1. Three phase multifunction din rail energy meter
SDM630MCT-RJV-333mV SDM630MCT-RJA-00mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free Measures kwh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.
More informationEnergy Management Modular Smart Power Transducer Type SPT-90
Energy Management Modular Smart Power Transducer Type SPT-90 Class 0.5 (current/voltage) 16-bit µp-based modular smart power transducer Measurements of: W, Wavg, VA, VAr, PF, Wh, VAh, VArh, Amax (among
More informationApplication Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters
Technical Data Sheet Alpha 20 Alpha 20 is a compact multifunction instrument which Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel
More informationMID. Energy Management Energy Meter Type EM33 DIN. Product Description. How to order EM33 DIN AV3 3 X XS PF. Type Selection EM33 DIN
Energy Management Energy Meter Type EM33 DIN Easy connections management Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X):
More informationInstallation and Operating Instructions
Energy Division Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Our commitment. Your advantage. Contents Page 1 Introduction 4 1.1 Measurement Capabilities 5 1.2
More informationMID. Energy Management Energy Analyzer Type EM Product Description. How to order EM26 96 AV5 3 H O3 S1 PF A. Type Selection EM26 96
Energy Management Energy Analyzer Type EM26 96 M-bus communication by means of VMU-B adapter Application adaptable display and programming procedure (Easyprog function) Easy connections management Certified
More informationMID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN
Energy Management Energy Analyzer Type EM11 DIN Other versions available (not certified, option X): see how to order on the next page Product Description Class 1 (kwh) according to EN62053-21 Class B (kwh)
More informationEnergy Management Energy Meter with plug-in Output Modules Type EM4-DIN
Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN Degree of protection (front): IP 40 Front dimensions: 9 DIN modules RS 422/485 Serial port by means of optional module Dual pulse
More informationEnergy Management Modular Power Analyzers Type WM2-96
ISE, Inc. - 10100 Royalton Rd. - Cleveland, OH 44133 USA Energy Management Modular Power Analyzers Type WM2-96 - Tel: (440) 237-3200 - Fax: (440) 237-1744 - http://instserv.com Class 1 Modular power analyzer
More informationNETWORK ANALYZERS Analyzers
CONTENTS PRODUCTS RANGE NA.03 NETWORK ANALYZER - LCC NETWORK ANALYZER - LCA NETWORK ANALYZER - LDA NETWORK ANALYZER - LAB96 NETWORK ANALYZER - LABM NA.04 NA.06 NA.09 NA.10 NA.13 NETWORK ANALYZER - LCCM
More informationMID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN
Energy Management Energy Meter Type EM23 DIN Certified according to MID Directive (option PF only): see how to order below Other version available (not certified, option X): see how to order on the next
More informationEnergy Management Modular Smart Power Quality Analyzer Type WM3-96
Energy Management Modular Smart Power Quality Analyzer Type WM3-96 Class 0.5 (current/voltage) 32-bit µp-based modular smart power quality analyzer Graph display (128x64 dots) Front size: 96x96 mm Measurements
More informationEnergy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302
Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302 Direct connection up to 65 A (WSx10x) Connection with current transformer (WSx30x) Industrial or meters
More informationEnergy Management Energy Analyzer Type EM210 MID
Energy Management Energy Analyzer Type Multi-use housing: for both DIN-rail and panel mounting applications MID annex MI-003 (Measuring Instruments Directive) compliant Class B (kwh) according to EN50470-3
More informationM.3. Electrical measurement and control. Electrical energy meters for partial consumption
M.3 Electrical measurement and control Electrical energy meters for partial consumption M.3 Electrical energy meters for partial consumption M.3 - Electrical energy meters for partial consumption Introduction
More informationIntegra 1560 and 1580 Digital Transducer Systems
Integra 1560 and 1580 multi function transducers provide high accuracy
More informationMultifunction network analyzer Q15U Q96U2L - Q96U4... Q15E Q96E MCU - MCUH Programmable transducer MCUU
Multifunction network analyzer Q15U2... - Q96U2L - Q96U4... Q15E2... - Q96E2... - MCU - MCUH Programmable transducer MCUU OPERATING MANUAL Ipm0163.8 - Edition 06.09 Langer Messtechnik GmbH Soyerhofstrasse
More informationDigital Multifunction Meter - RISH Integra 2000
Features Four line graphic LCD display 1+ parameters Fast communications Customer configurable Easy to use Output options: 4 x -1mA 4 x 4-2mA 1 or 2 energy pulses Panel mounted Neutral current measurement
More informationPowerLogic power-monitoring units. PM700 series power meter. Technical data sheet
PowerLogic power-monitoring units PM700 series power meter Technical data sheet 2009 Functions and characteristics The PowerLogic PM700 series power meter offers all the measurement capabilities required
More informationElectrical network management. Schneider Electric. PM3200 Technical Datasheet
Electrical network management Schneider Electric PM3200 Technical Datasheet Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact
More informationMultimeter 500CVD21 RTU500 series
Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase
More informationEnergy Management Power Analyzer with plug-in Output Modules Type W M22-DIN
Energy Management Power Analyzer with plug-in Output Modules Type W M22-DIN Front dimensions: 9 DIN modules Analogue output by means of optional module (20mA or 10VDC) RS 422/485 Serial port by means of
More informationTechnical Data Sheet AMIK 300 / 301
USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet AMIK 300 / 301 LISTED File No. E471457 AMIK AMIK 300 is a compact multifunction instrument with touch screen LCD utility which measures important
More informationEnergy Management Smart Modular Power Analyzer Type WM30 96
Energy Management Smart Modular Power Analyzer Type WM30 96 Front protection degree: IP65, NEMA4X, NEMA12 One RS232 or RS485 port (on request) Communication protocol: MODBUS-RTU, ifix SCADA compatibility
More informationPower quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I
Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)
More informationRISH Master 3430 DIGITAL MULTI-FUNCTION TRANSDUCER. Electro-Meters
measures important electrical parameters in phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, Power, Energy
More informationEnergy Management Modular Universal Utility Meter and Power Analyzer Type WM4-96
Energy Management Modular Universal Utility Meter and Power Analyzer Type WM4-96 Class 0.5 (current/voltage) Universal meter: energy, water and gas 32-bit µp-based multifunction power analyzer Back-lighted
More informationEnergy Management Energy Meter GM3T E GM3T-RS485 E
Energy Management Energy Meter GM3T E09 814 96 GM3T-RS485 E09 816 65 Certified according to MID Directive Product Description Three-phase energy meter with removable front LCD display unit. The same unit
More informationModel Range code System Power supply Option. variables. Housing for panel mounting, (front) protection degree IP50 and optional RS485 serial output.
Power analyzers and Energy Meters Multifunction indicator Type WM12-96 Accuracy ±0.5 F.S. (current/voltage) Multifunction indicator Display of instantaneous variables: 3x3 digit Variable system and phase
More informationEnergy Management Energy Meter Type EM21 72R Retro-Fit
Energy Management Energy Meter Type EM21 72R Retro-Fit Including 3 miniature split-core current sensors 10mm (90A), 16mm (150A) and 24mm (250A) diameter holes Class A (kwh) according to EN50470-3 Class
More informationEnergy Management Energy Analyzer Type EM210
Energy Management Energy Analyzer Type EM210 Multi-use housing: for both DIN-rail and panel mounting applications Current inputs AV option: CT 5A Current inputs MV option: current sensor 333 mv (CTV series)
More informationN30P DIGITAL PANEL METER
N30P DIGITAL PANEL METER Features: NEW Measurement of single-phase network parameters: voltage, current, active, reactive and apparent power, cosj, tgj, j, frequency, active, reactive and apparent energy,
More informationMultifuncion Measuring Device, 4 mod. DIN, connection via CT, with RS485 port
Viale Borri 231, 21100 Varese Italy Multifuncion Measuring Device, 4 mod. Contents Pages 1. Description Use... 2 2. Range... 2 3. Overall dimensions... 2 4. Preparation Connection... 2 5. General characteristics...
More informationUMG 103-CBM. Universal measurement device for DIN rails
Universal measurement device for DIN rails Harmonics GridVis Analysis software Modbus interface Measurement accuracy 0.5 Communication Protocols: Modbus RTU / Slave Interface RS485 Accuracy of measurement
More informationSUPPLY NETWORK ANALYZER CVM-96 SERIES
SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY
More informationSide view View from below Rear view
Dimension diagrams All dimensions in mm Side view View from below Rear view Cut out: 138 +0,8 x 138 +0,8 mm Typical connection SPS SPS 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 DSUB-9 5 4 3 2 1 8 7 6 5 4
More informationInstallation Instructions and Reference Handbook. Installation instructions
Installation Instructions and Reference Handbook Multi-instrument MIB 7000/7000C/7020 4189320016B (UK) DEIF A/S Product information Installation instructions Basic operation DEIF A/S, Frisenborgvej 33
More informationCVM-C5-ITF-485 CVM-C5-MC-485
Power analyzer CVM-C5-ITF-485 CVM-C5-MC-485 CVM-C5-mV-485 INSTRUCTION MANUAL (M026B01-03-18A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below DANGER Warns
More informationNetworks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM
Power quality Colour graphical display Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management UMG 508 Multifunction power analyser Communication Profibus (DP/V0) Modbus (RTU,
More informationPOWER ANALYZER CVM-MINI SERIES INSTRUCTION MANUAL M A CIRCUTOR, SA
POWER ANALYZER CVM-MINI SERIES INSTRUCTION MANUAL M98174001-03-15A CIRCUTOR, SA CONTENTS 1 BASIC INSTRUCTIONS... 3 1.1 Checks on receipt.... 3 1.2 Main features... 3 1.3 Electrical parameters... 3 1.4
More informationSmart Energy & Power Quality Solutions. UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC)
Smart Energy & Power Quality Solutions UMG 96RM Universal measurement instrument (EN 50160, IEEE 519, ITIC) UMG 96RM UMG 96RM Universal measurement instrument Unrivalled in its class The UMG 96RM is a
More informationEnergy Management Energy Analyzer Type EM24 DIN
Energy Management Energy Analyzer Type EM24 DIN Protection degree (front): IP50 RS485 serial output (on request) (MODBUS-RTU), ifix SCADA compatibility Application adaptable display and programming procedure
More informationDigital Multifunction Instrument - Rish Master 3440
Application Rish Master 3440 measures important electrical parameters in 3 phase and single phase etwork & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationEnergy Management Energy Meter Type EM340
Energy Management Energy Meter Type EM340 Digital input (for tariff management Easy connection or wrong current direction detection Certified according to MID Directive (option PF only: see how to order
More information1 2 3 GridVis Pulse output 2 tariffs Modbus MID M-Bus
speicher MID energy meter ECSEM series Emax 2 Tariffs GridVis 7 Tariffs 8 Tariffs 14 Tariffs 0,2 kwh Class 0,5 kwh Class 1,0 kwh Class Pulse output Tarife 2 tariffs Messgenauigkeit Modbus MID M-Bus eratureingang
More informationEnergy Division
Energy Division http://energy.tycoelectronics.com Installation and Operating Manual Integra 1560 and 1580 Digital Metering and Transducer Systems Tyco Electronics UK Limited Crompton Instruments Freebournes
More informationUPM209 1/5A CT, 80A Multifunction three-phase meter
1/5A CT, 80A Multifunction three-phase meter 4 DIN modules compact version Fully bi-directional four quadrants measurements for all energies and powers Main electrical parameters measured and displayed
More informationCentrale de mesure Power Meter PM500 Merlin Gerin
Notice d'installation et d'utilisation Installation and user manual Centrale de mesure Power Meter PM500 Merlin Gerin 059473_D Introduction and description Package contents c one PM500 power meter with
More informationEnergy Management. Type WM14-DIN Basic Version. How to order WM14-DIN AV5 3 D PGX. Type Selection. Input specifications. CptBSoft
Energy Management Power Analyzer ype WM-DI Basic Version Optional dual pulse output Alarms (visual only) V L, An Optional galvanically insulated measuring inputs Product Description ype Selection Range
More informationPower Quality and Energy Measurement PEM575
Power Quality and Energy Measurement _D00016_03_D_XXEN/12.2015 Power Quality and Energy Measurement Product description The digital universal measuring device is suited for measuring and displaying electrical
More informationUMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.
Harmonics GridVis Analysis software Modbus interface Measurement accuracy 0.5 Universal measurement device for DIN rails Communication Protocols: Modbus RTU / Slave Interface RS485 Power quality Harmonics
More informationPower Quality and Energy Measurement PEM533
Power Quality and Energy Measurement _D00013_02_D_XXEN/11.2014 Power Quality and Energy Measurement 0.5 S Product description The digital universal measuring device is suited for measuring and displaying
More informationDimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung
Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply
More informationEnergy Management Energy Analyzer Type EM24 DIN
Energy Management Energy Analyzer Type EM24 DIN Protection degree (front): IP50 RS485 serial output (on request) (MODBUS-RTU), ifix SCADA compatibility Dupline communication capability (DP option) Application
More informationAMIK 200 / 201 Technical Data Sheet
AMIK 200 / 201 Technical Data Sheet AMIK Special Features MODBUS (RS-485) Communication available only on Amik 201 On site Programmable CT/PT Ratios User selectable CT Secondary 1A/5A User selectable PT
More informationMeasuring centers MC7x0 series Multifunction Meter MC740
Measuring centers MC7x0 series Multifunction Meter MC740 o Measurements of instantaneous values of more than 130 quantities (U, I, P, Q, S, PF, PA, f, φ, THD, MD, energy, energy cost by tariffs, etc.)
More information3-phase meter with direct connection and pulse or Modbus RS485 output
87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 3-phase meter with direct connection and CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...
More informationInstallation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems
Installation and Operating Instructions Quadratic Integra 1530 Digital Metering Systems Tyco Electronics UK Limited Crompton Instruments Freebournes Road, Witham, Essex, CM8 3AH, UK Tel: +44 1376 509 509
More informationEnergy Management Modular Smart Power Quality Analyzer Type WM5-96
Energy Management Modular Smart Power Quality Analyzer Type WM5-96 MODBUS RTU and TCP, JBUS protocol, ifix SCADA compatibility Real time clock function (without back-up) Up to optional digital inputs (sync
More informationRISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:
(With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network
More informationUMG 509-PRO. Multifunction power analyser with RCM
UMG 509-PRO Multifunction power analyser with RCM Power quality RCM Residual current monitoring Ethernet connection Ethernet-Modbus gateway Graphic programming Alarm management Communication Profibus (DP/V0)
More informationEnergy Management Modular Power Quality Transducer Type PQT-90
Energy Management Modular Power Quality Transducer Type MODBUS RTU, JBUS protocol Transmission and reception of SMS messages (variables and alarm status) Data transmission and reception by means of analogue
More informationEnergy Management Modular Smart Power Quality Analyzer Type WM5-96
Energy Management Modular Smart Power Quality Analyzer Type MODBUS RTU, JBUS protocol, ifix SCADA compatibility Real time clock function (without back-up) Up to optional digital inputs (sync function,
More information