EMC TEST REPORT 2G-2S.0.3.FC-BOX. METEL s.r.o., Žižkův Kopec 617, Česká Skalice. Measured Date Type Version DPS SN
|
|
- Silvia Miles
- 6 years ago
- Views:
Transcription
1 EMC TEST REPORT METEL s.r.o., Žižkův Kopec 617, Česká Skalice 2G-2S.0.3.FC-BOX - 1 -
2 Immunity Testing - Electrostatic Contact Discharge Test No. 1: EN ed.2 Device Used: SRG200LC Description of Connection: The EUT "2G-2S.0.3.FC-BOX" was connected sequentially from the ports G1 and G2 (1000Base-FX) with EXFO-P1 (1000Base-FX) and from the ports P1 to P3 was connected sequentially through media converter (2G- 1S.1.0) with EXFO-P2 (1000Base-FX). The media converter and EUT were connected with EXFO 1m long SM fiber. The EUT and media converter were connected with 1m long UTP cable. The EUT was separately powered from a 48VDC separate power supply (isolating transformer 230AC / 230AC, 230AC power supply / 42-56VDC). Other device was supplied from an external source. The test was used to demonstrate, resistance to electrostatic discharge. Universal Connection Scheme: Power supply Insulating support Direct discharge to EUT Indirect discharge to VCP Indirect discharge to HCP HCP Protective conductor EUT VCP 470kΩ 0,1 m 0,1 m Horizontal copling plane (HCP) 470kΩ Ground reference plane (GRP) 470kΩ 470kΩ Power supply Non-conducting table - 2 -
3 Scheme: Results: Level Of Test kv Result Comment 2 4 (-)b / (+)b 5x negative pulses / 5x positive pulses 3 6 (-)b / (+)b 5x negative pulses / 5x positive pulses 4 8 (-)b / (+)b 5x negative pulses / 5x positive pulses Measured Date Type Version DPS SN Ivo Humeňuk 1st November G-2S.0.3.FC-BOX 2G-2S03_PWRIO_ / 0-3- Unknown
4 Immunity Testing - Electrostatic Air Discharge Test No. 2: EN ed.2 Device Used: SRG200LC Description of Connection: The EUT "2G-2S.0.3.FC-BOX" were involved similarly to resistance tests - Electrostatic contact discharge (Test No. 1). The test demonstrated the resistance to electrostatic discharge. Results: Level Of Test kv Result Comment 2 4 (-)a / (+)a 5x negative pulses / 5x positive pulses 3 8 (-)b / (+)b 5x negative pulses / 5x positive pulses 4 15 (-)b / (+)b 5x negative pulses / 5x positive pulses Immunity Testing Electrical Fast Transient / Burst Test No. 3: EN ed.3 Device Used: Generator RG451, Capacitive Coupling Clamp KK 401 Description connection: The EUT "2G-2S.0.3.FC-BOX" using the same connection scheme as the test "EN " only for application BURST with coupling clamp we using a 2m length UTP cable. The EUT was separately powered from a 48VDC separate power supply (isolating transformer 230AC / 230AC, 230AC power supply / 42-56VDC). The other equipment was supplied from an external source. For the application interference BURST we used capacitive coupling clamp connected to the coaxial HV output on BURST tester. The length of each test was 60 seconds
5 Scheme: EUT line Electrical Fast Transient / Burst Coupling Clamp line AUX EQUIP. 0,1 m insulating support 0,1 m insulating support Ground reference plane (GRP) Generator BURST GND Grounding connection according to the manufacturer s specifications Results: BURST on PORT 1 Level Of Test kv / KHz Result Comment 2 1 / 5KHz (-)b / (+)b (-)/(+) length 60sec 3 2 / 5KHz (-)b / (+)b (-)/(+) length 60sec 4 4 / 5KHz (-)b / (+)b (-)/(+) length 60sec BURST on PORT 2 Level Of Test kv / KHz Result Comment 2 1 / 5KHz (-)b / (+)b (-)/(+) length 60sec 3 2 / 5KHz (-)b / (+)b (-)/(+) length 60sec 4 4 / 5KHz (-)b / (+)b (-)/(+) length 60sec BURST on PORT 3 Level Of Test kv / KHz Result Comment 2 1 / 5KHz (-)b / (+)b (-)/(+) length 60sec 3 2 / 5KHz (-)b / (+)b (-)/(+) length 60sec 4 4 / 5KHz (-)b / (+)b (-)/(+) length 60sec - 5 -
6 Immunity Testing Surge Pulse Test No. 4: EN ed.2 Device Used: Generator RG451 Description of Connection: The EUT "2G-2S.0.3.FC-BOX" using the same connection scheme as the test "EN (Test No. 1)". For surge pulse application (SURGE No. 1) with output impedance 42 Ohms we using modified UTP cable connected to the generator (UTP cable with brought-out twist coule for connection to the generátor). Test (1,2) x (PE) / (3,6) x (PE) / (4,5) x (PE) / (7,8) x (PE) / (1,2,3,6,4,5,7,8) x (PE). After surge impulse we controlled the functioning EUT using the auxiliary equipment (EXFO). (SURGE No. 1: level 2 procedure 11 20, level 3 procedure 21 30). Tested ethernet ports P1, P2, P3 are equipped only with low surge protection, thus have been tested only to level 3. Scheme: Generator combined wave Ancillary Equipment Protection Equipment Separation Network Reference Ground - 6 -
7 Results: PORT P1 Wire (1,2)-(PE) Wire (3,6)-(PE) Wire (4,5)-(PE) Wire (7,8)-(PE) Wire (1,2,3,4,5,6,7,8) -(PE) - 7 -
8 Results: PORT P2 Wire (1,2)-(PE) Wire (3,6)-(PE) Wire (4,5)-(PE) Wire (7,8)-(PE) Wire (1,2,3,4,5,6,7,8) -(PE) - 8 -
9 Results: PORT P3 Wire (1,2)-(PE) Wire (3,6)-(PE) Wire (4,5)-(PE) Wire (7,8)-(PE) Wire (1,2,3,4,5,6,7,8) -(PE) - 9 -
10 Immunity Testing Static Magnetic Field 50 Hz Test No. 5: EN ed.2 Device Used: Autotransformer 2,3kW / Conversion transformer 2KVA, Ring coil 20mH/1m; 2x Tripod for mounting coil; insulation pad Description of Connection: The EUT "2G-2S.0.3.FC-BOX" was exposed a static magnetic field. The EUT using the same connection scheme as the test "EN " only to ensure the remoteness of the test device from the neighborhood we using 5m UTP cables and 3m SM optical fiber. The equipment tested was separately powered from a 48VDC separate power supply. We gradually changed position the EUT to the reference surface (0 / 45 / 90 ) during the test. The length of each test was 60 seconds. During the test we controlled the functioning of the EUT. Scheme: L ATR ITR N A EUT PE Results: Level Of Test A/m Result Comment (-)a / (+)a length 60sec (0 /45 /90 ) (-)a / (+)a length 60sec (0 /45 /90 )
11 Immunity Testing Pulse Magnetic Field Test No. 6: EN Device Used: Generator RG451 output COIL; Square coil 0,6m x 0,6m; insulation pad; tripod for mounting coil Description of Connection: The EUT "2G-2S.0.3.FC-BOX" was exposed to pulsed magnetic field. The EUT using the same connection scheme as the test "EN (Test No. 1)" only to ensure the remoteness of the test device from the neighborhood we using 5m UTP cables and 3m SM optical fiber. We gradually changed position the EUT to the reference surface (0 / 45 / 90 ) during the test. During the test we controlled the functioning of the EUT. Chosen procedure SRG1 No10. Scheme: Generator EUT (GRP) Twisted cable length maximum 2 m GND Separate source Results: Level Of Test A/m Result Comment (-)a / (+)a 5x negative pulses / 5x positive pulses (period 1sec)(0 /45 /90 ) (-)a / (+)a 5x negative pulses / 5x positive pulses (period 4sec)(0 /45 /90 ) (-)a / (+)a 5x negative pulses / 5x positive pulses (period 6sec)(0 /45 /90 )
EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS
EMC-E20130903E EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS Prepared for : MPP SOLAR INC Address : 4F, NO. 50-1, SECTION 1, HSIN-SHENG S. RD. TAIPEI, TAIWAN Prepared by
More informationEMC standards. Presented by: Karim Loukil & Kaïs Siala
Training Course on Conformity and Interoperability on Type Approval testing for Mobile Terminals, Homologation Procedures and Market Surveillance, Tunis-Tunisia, from 20 to 24 April 2015 EMC standards
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25
15072259 001 Seite 2 von 25 Page 2 of 25 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE 4.1.4 DISCONTINUOUS INTERFERENCE
More information2620 Modular Measurement and Control System
European Union (EU) Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) Test Report 2620 Modular Measurement and Control System Sensoray March 31, 2006 April 4, 2006 Tests Conducted by: ElectroMagnetic
More informationImmunity Testing for the CE Mark
Immunity Testing for the CE Mark Summary The European Union (EU) currently has 25 member countries with 2 additional countries to be added in 2007. The total population at that time will be nearly a half
More informationEMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)
EMC TEST REPORT For Company Limited Liability «Faraday Electronics» Switching Mode Power Adaptor Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A) Prepared For : Company Limited Liability «Faraday
More informationEMC TEST REPORT. Report No.: CE10-LIE040101E
EMC TEST REPORT Report No.: CE10-LIE040101E Product: LED TUBE Model No.: T10, T8, T5 Applicant: Shenzhen Saiju Electronic Co., Ltd. Address: 2nd. Xianshun Industrial Park, Gushu, Xixiang, Bao an, Shenzhen,
More informationEMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter
Page 1 of 48 EMC TEST REPORT for Coliy Technology Co.,Ltd. Fluxgate Gaussmeter Prepared for : Coliy Technology Co.,Ltd. Address : Block B,9 th Floor,Xinzhongtai Business Building,Gushu 2nd Road,Xi Town,Bao
More informationOverview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University
Overview of EMC Regulations and Testing Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University What is EMC Electro-Magnetic Compatibility ( 電磁相容 ) EMC EMI (Interference) Conducted
More informationLS200 TEST DATA IEC61000 SERIES
TEST DATA IEC61000 SERIES DWG. No. PA607-58-01 APPD CHK DWG TDK-Lambda INDEX LS200 PAGE 1. Electrostatic Discharge Immunity Test (IEC61000-4-2) R-1 2. Radiated Radio-Frequency Electromagnetic Field Immunity
More informationTEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed
17035561 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 5.1.1 HARMONICS ON AC MAINS RESULT: Passed 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Passed 5.1.3 TERMINAL CONTINUOUS DISTURBANCE VOLTAGE AT RESULT:
More informationEMC Seminar Series All about EMC Testing and Measurement Seminar 1
EMC Seminar Series All about EMC Testing and Measurement Seminar 1 Introduction to EMC Conducted Immunity Jeffrey Tsang Organized by : Department of Electronic Engineering 1 Basic Immunity Standards: IEC
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27
15072768 001 Seite 2 von 27 Page 2 of 27 TEST SUMMARY 4.1.1 HARMONICS ON AC MAINS 4.1.2 VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER ON AC MAINS 4.1.3 MAINS TERMINAL CONTINUOUS DISTURBANCE VOLTAGE
More informationTEST REPORT... 1 CONTENT...
CONTENT TEST REPORT... 1 CONTENT... 2 1 TEST RESULTS SUMMARY... 3 2 EMC RESULTS CONCLUSION... 4 3 LABORATORY MEASUREMENTS... 6 4 EMI TEST... 7 4.1 CONTINUOUS CONDUCTED DISTURBANCE VOLTAGE TEST... 7 4.2
More informationSchlöder GmbH - EMC Test and Measurement Systems Model #
Schlöder GmbH - EMC Test and Measurement Systems Model # Product Description IEC / EN 61000-4 - 2 ESD SESD 216 ESD generator 10 kv CON / 16,5 kv AIR acc. to IEC 61000-4-2, 150 pf / 330 ohm SESD 230 ESD
More informationEMC TEST REPORT. For. Soma Medical (Sabah) Sdn Bhd ( D) UVGI AIR STERILIZER. Model No.: SM 20
EMC TEST REPORT For Soma Medical (Sabah) Sdn Bhd (1248058-D) UVGI AIR STERILIZER Model No.: SM 20 Prepared For : Soma Medical (Sabah) Sdn Bhd (1248058-D) : Block E, Lot 28, 2nd floor, Signature Office,
More informationEN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd
Page 1 of 15 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EN61326 EMC COMPLIANCE
More informationCombination Wave Test System
Immunity Tests Combination Wave Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................
More informationIntroduction EMC. Filter parameters. Definition of EMC / EMI. X-Capacitor. Sources of EMI. Coupling mechanism. Y-Capacitor.
Introduction to EMC Schurter has over 75 years experience in the electronics and electrical industries, developing and manufacturing components that ensure a clean and safe supply of power. Schurter provides
More informationEN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A
Reference No.: WT12106773-N-S-E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 150KHz to 30MHz Radiation Emission, 30MHz to 1000MHz EMISSION Test Standard Class / Severity Result
More informationTest Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator EAST ZTY-30KVA Date of Receipt : Aug. 30, 2013 Date of Test: Sep. 03, 2013
More informationTest Report GUANGDONG EAST POWER CO., LTD
Test Report Applicant: Product Name: Brand Name: Model No.: GUANGDONG EAST POWER CO., LTD Online High Frequency UPS EAST EA906IIRTS, EA906IIRTH Date of Receipt : Feb. 26, 2014 Date of Test: Mar. 24, 2014
More informationDiscontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz
Reference No.: WTN13F0706038E Page 2 of 40 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz EMISSION Test Standard Class / Severity Result
More informationEMC Test Report. Report Number: M030826
Page 1 of 36 EMC Technologies Pty Ltd ABN 82 057 105 549 57 Assembly Drive Tullamarine Victoria Australia 3043 Ph: + 613 9335 3333 Fax: + 613 9338 9260 email: melb@emctech.com.au EMC Test Report Report
More informationEN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass
Reference No.: WTD15S0730643E Page 2 of 42 1 Test Summary Test Item Conducted Disturbance at Mains Terminal, 9kHz to 30MHz Radiation electromagnetic disturbance, 9kHz to 30MHz Radiation Emission, 30MHz
More informationCommunication Certification Laboratory
Communication Certification Laboratory November 29, 2006 Mr. Samuel Smith Adept Systems Inc. 2966 Fort Hill road Eagle Mountain, UT 84005 Dear Sam: Communication Certification Laboratory has completed
More informationTechnical Specification
LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification No. E-MIG0603IN2.doc revised: 20.October 2004 1 MIG Tester Type MIG0603IN2 1 MIG Tester Type MIG0603IN2 1 1.1 Introduction 1 2
More informationHigh precision measurement system for current and voltage IHC-A/B-RM01/03
Measurement Offset-free and low-noise 16 bit data acquisition system ISA-ASIC Internal sample rate 3,500 Hz Communication Standard RS232- or RS485 interface Advantages Direct measurement on the bus bar
More informationIEC Electrical fast transient / Burst immunity test
CONDUCTED RF EQUIPMENT POWER AMPLIFIERS IEC 61000-4-4 Electrical fast transient / Burst immunity test IEC 61000-4-4 Electrical fast transient / Burst immunity test Markus Fuhrer Phenomenom open a contact
More informationTEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass
Seite 2 von 35 Page 2 of 35 TEST SUMMARY 5.1.1 HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass 5.1.2 VOLTAGE FLUCTUATIONS ON AC MAINS RESULT: Pass 5.1.3 CONDUCTED DISTURBANCE AT THE MAINS PORTS RESULT:
More informationHarmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass
Reference No.: WTS15F0323845E Page 2 of 33 1 Test Summary Test Item Mains Terminal Disturbance Voltage, 148.5kHz to 30MHz Disturbance Power, 30MHz to 300MHz Discontinuous Disturbance (Click) Radiated Emission,
More informationEMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19
EMC TEST REPORT Page : 1 of 19 Equipment Under Test Model No. Applicant Address of Applicant : Bluetooth Headset : FB-HS01 : Formosa Teletek Corporation : 358, Huaya 2 nd Rd., Gueishan shiang, Taoyuan,
More informationBS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE
Page 1 of 18 Interference Testing And Consultancy Services (Pty) Ltd ITC SERVICES (PTY) LTD Reg 88/002032/07 Plot 44 Kameeldrift East, Pretoria Private Bag X13 Lynn East 0039 Republic of South Africa Tel
More informationMCR-VAC-UI-0-DC. Voltage transducer for AC voltages. INTERFACE Data sheet _en_02. 1 Description
Voltage transducer for AC voltages TERFACE Data sheet 006_en_0 PHOENIX CONTACT 00-0- Description The MCR voltage transducer measures AC voltages in several signal ranges from 0... ±4 V AC to 0... ±30 V
More informationTelecom Test System. Lightning Tests
Lightning Tests Telecom Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 4 Generator Specifications.................
More informationEMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B
Page 1 of 27 Report No. R011412016E-1 EMC TEST REPORT for LEDELS LIGHTING CO., LTD LED module Model No. : LL-F12T4815X6B Prepared for : LEDELS LIGHTING CO., LTD Address : 5F, Block C, Mingjinhai Ind. Park,
More informationA) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23
D I R E C T O R Y A) Documentation Page(s) Test report 1-17 Directory 2 Test Regulations 3 General Remarks and Summary 17 Test-setups (Photos) 18-23 B) Test data: Immunity against Electrostatic discharge
More informationITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA
Shenzhen BST Technology Co., Ltd. ITUNER NETWORKS CORPORATION EMC REPORT Prepared For : ITUNER NETWORKS CORPORATION 47801 Fremont Blvd. Fremont, CA. 94538 Product Name: PicoPSU-150 Trade Name: PicoPSU
More informationEMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
EMC-Report No.:SZZCT1502030B-EMC-02 EMC Test Report Product Model Number : Drift car : P01 Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China
More informationSign: Replace: Date:
Danfoss EMC-lab. Subj: PAJ WIO Sensor 200. Marine EMC test Technical report 2009-02260 GS-VTTE Author: K. Christiansen Sign: Replace: Date: 2009-09-24 Page 1 of 28 Sent to: Tim Flintholm Fink, PAJ Systemteknik
More informationE M C T E S T Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT & E M C. w w w. h v t e c h n o l o g i e s. c o m
E M C T E S T S O L U T I O N S P A R T N E R S F O R H V & E M C S O L U T I O N S Y O U R SOURCE FOR TOP Q U A L I T Y TEST EQUIPMENT w w w. h v t e c h n o l o g i e s. c o m Transient Immunity Generators
More informationTrees, vegetation, buildings etc.
EMC Measurements Test Site Locations Open Area (Field) Test Site Obstruction Free Trees, vegetation, buildings etc. Chamber or Screened Room Smaller Equipments Attenuate external fields (about 100dB) External
More information1 SUMMARY OF STANDARDS AND RESULTS
1 SUMMARY OF STANDARDS AND RESULTS 1.1 Description of Standards and Results The EUT have been tested according to the applicable standards as referenced below: EMISSION Description of Test Item Standard
More informationEMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv
EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED ITaste vv Model No.: ITaste vv Prepared for : INNOKIN TECHNOLOGY CO., LIMITED Address : 3# Floor, #B Building, Heng Chang Rong Industrial Park, Gonghe
More informationr(oilgln TEST REPORT 'AGREB 6 %P\l Br EMC10001 sasa Gros, B.s"{h-$ INSTITUTE EMC and Safetv Laboratorv
r(oilgln Electrlcal Engin.erlng INSTITUTE Br. 21583EMC10001 TEST REPORT EMC and Safetv Laboratorv Page/Pages:1 /40 Test item: CT Powered Time Over-current relay Model: SIGMA XS Manufacturer: KONCAR - ELEKTRIcNI
More informationNovità sulla IEC ; -10; -12
Novità sulla IEC 61000-4-9; -10; -12 DIPL. ING. MARKUS FUHRER 11.06.2018 Content Recently revised standards IEC 61000-4-9 Ed. 2.0 2016-07 Impulse magnetic field IEC 61000-4-10 Ed. 2.0 2016-07 Damped oscillatory
More informationAPPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:
APPLICATION FOR EMC DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co., Ltd led flood light Trade Name: Model: QH-TGC-400W, QH-TGC-300W, QH-TGC-500W, QH-TGC-800W, QH-TGC-1000W Prepared For : Shenzhen
More informationEMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD
Page 1 of 45 Report No. R011607240E EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD INVERTER CHARGER Model No.: PV35-4K DC24V MPK, PV35-4K DC48V MPK, PV35-5K DC48V MPK, PV35-6K DC48V MPK Prepared
More informationC B. Models. Models 2MOPP
AC/DC Medical Power Supplies High power density 3" x 5" open frame medical power supply 450 Watt with forced air cooling 320 Watt convection cooled without derating up to 50 C Medical certification to
More informationAnalog signal converters CC-E I/I
2CC 281 001 F0b06 Features Loop-powered I/I isolator without external power supply for analog current signals of 0-20 ma and 4-20 ma Electrical isolation between input and output Very low internal voltage
More informationEMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A
EMC Test Report Applicant: Address of Applicant: Trade Name: FATEK AUTOMATION CORP. 26FL, NO.29, SEC.2, JUNGJENG E. RD., DANSHUEI DIST., NEW TAIPEI CITY, TAIWAN, R.O.C. FATEK Equipment Under Test: Training
More informationReport for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027
Report for Excelsys on EMC Measurements for 6Xgen Purchase Order: by email Project Number EMT08J027 Tom O Brien, Engineering Director ElectroMagnetic Technologies Ltd, Cork, June 2007 Executive Summary
More informationALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)
Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA
More information83 Series - Modular timers 16 A. Features
Features 83 Series - Modular timers 16 A 83.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 83.11 - delay, multi-voltage 22.5 mm wide Six time scales from 0.1s to 20h High
More informationInsulation Test System
Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................
More informationEMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8
EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8 Prepared for Address : ShenZhen ZhangQing Electronic LTD :
More informationVOLTAGE DETECTING SYSTEMS
INTEGRATED OPTOELECTRIC SYSTEM OF VOLTAGE DETECTION WITH TOTAL SAFETY GUARANTEED BY GALVANIC INSULATION AND INTERNAL FAULT SUPERVISION pag.1 di 13 INDE 1.PREVIEW.. 3 2.GENERAL.. 3 3.STANDARD REFERENCES..
More informationDIRECTORY - EMISSIONS
DIRECTORY - EMISSIONS A) Documentation Pages Test Report 1-12 Directory 2 Test Regulations 3 General Remarks and Summary 12 Test Setups (Photographs) 13-16 B) Test Data Conducted Emissions 9/150/450 khz
More informationUCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV
UCS 500N7 MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS (EFT/BURST, SURGE & POWER FAIL) UP TO 7KV FOR TESTS ACCORDING TO... > IEC 61000-4-4 > IEC 61000-4-5 > IEC 61000-4-8 > IEC 61000-4-9 > IEC 61000-4-11
More informationCE EMC Test Report GUANGZHOU DMKEMOTOR CO. LTD
CE REPORT CE EMC Test Report Equipment under Test: Model /Type: Applicant: Address: Manufacturer: Address: Laboratory: Address: Report Number Brush D.C. Motor D5D120-24GU D2D10-12GN, D2D10-24GN, D2D10-36GN,
More informationEN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments
EMC Page 3 / 33 Test report No.: EN 61000-6-3:2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments Date of measurement: 2013-10-16
More informationsatech SynchroStar GPS 200 Series
satech SynchroStar GPS 200 Series KEY BENEFITS Designed with high quality oscillator OCXO the device is characterized by superior frequency stability and improved holdover performance that allows maintaining
More informationEMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45
REPORT NO. PRSZ15110502E EMC TEST REPORT For Boardcon Technology Limited. MINI9G45 Computer on Module Model No. : MINI9G45 Prepared For : Boardcon Technology Limited. : Room 702, Hua Feng Xin An Business
More informationBy order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan
4322705.50 EMC Test report for Plug-in adaptor Models PM1W-IT, PM1WU2-IT, PM1W-GR, PM1W-SP, PM1W-RS, PM1WB-RS, PM1WU2-GR, PM1WU2-SP, PM1WU2-RS, PM1WBU2-RS, PM1W-UK, PM1WU2-UK, PM1W-FR, PM1WU2-FR Guangzhou,
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationCE-EMC TEST REPORT. Prepared for : T&T Assoociates London LTD Suite#306 CityGate House, Bussinedd Centre Stratford, Romford Road, London
CE-EMC TEST REPORT Prepared for : T&T Assoociates London LTD Suite#306 CityGate House, Bussinedd Centre Stratford, 246-250 Romford Road, London Product: CCTV Camera Trade Name: Model Name: INNOVEXS IPBQH20HH205,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE. (Main Laboratory) Onna, Atsugi-shi, Kanagawa-ken, Japan
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AMETEK CO., LTD. NAGOYA OFFICE (Main Laboratory) 5-1-1 Onna, Atsugi-shi, Kanagawa-ken, 243-0032 Japan (Commercial Office) 1-329 Kifune, Meito-ku Nagoya-shi,
More informationGuangdong East Power Co., Ltd. Uninterruptible Power Systems
Test Report Applicant: Product Name: Brand Name: Model No.: Guangdong East Power Co., Ltd. Uninterruptible Power Systems EAST EA8806, EA8804 Date of Receipt : Nov. 01, 2012 Date of Test: Nov. 03, 2012
More informationETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.
ETSI EN 301 489-1 V2.2.0 (2017-03) ETSI EN 301 489-3 V2.1.1 (2017-03) TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-10P Report Type: Amended Report
More informationUCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.
UCS 500N5T SERIES MULTIFUNCTIONAL TESTGENERATOR FOR CONDUCTED TRANSIENTS (EFT/BURST, SURGE, TELECOM-SURGE & POWER FAIL) UP TO 5.5KV FOR TESTS ACCORDING TO... > EN 300329 > EN 300340 > EN 300342-1 > EN
More information83 SERIES. 83 Series - Modular timers A. Features
Features 83 Series - Modular timers 12-16 A 83.01 83.02 83 Multi-function timer range 83.01 - Multi-function & multi-voltage, 1 Pole 83.02 - Multi-function & multi-voltage, 2 Pole (timed + instantaneous
More informationAlternative Coupling Method for Immunity Testing of Power Grid Protection Equipment
Alternative Coupling Method for Immunity Testing of Power Grid Protection Equipment Christian Suttner*, Stefan Tenbohlen Institute of Power Transmission and High Voltage Technology (IEH), University of
More informationTEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54
Equipment Under Test Brand Name Model No. Added Model(s) Applicant Address of Applicant Page : 1 of 54 TEST REPORT : AC Servo Motor : Kingservo : AC 400W servo motor : N/A : Ho Fo Automation CO., LTD :
More informationContents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient. 3 Electromagnetic Interference
Issue 3, October 2002 Electromagnetic Compatibility and Electrical Safety Contents Telcordia GR-1089 - Documentation Information Generic Requirements Notice Of Disclaimer................. iii Contents.......................................
More informationCAR - TEST - SYSTEM 14
CAR - TEST - SYSTEM 14 EMC-Test Equipment for electrical installation of vehicles Acc. to ISO 7637-2, ISO 16750-2 ISO 21848 Rise time variable 1-5µs Pulse Waveforms : #1 1-5/2000µs, 600 V, ISO 1-5/1000µs,
More informationHigh-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime
Issued: 5.06.999 Status: 5.06.999 Version: B/09..00 Data subject to change without notice Features Overvoltage and undervoltage protection Single- or three-phase operation High-set overvoltage stage with
More informationEMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS
EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS Prepared For : Prepared By : Changzhou Airwheel Technology Co.,Ltd. Fl.5, East of No. 10 Building, high-tech
More informationUCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY
UCS 500N7.2 MULTIFUNCTIONAL TRANSIENT SIMULATOR FOR RENEWABLE ENERGY FOR TESTS ACCORDING TO... > ANSI/IEEE C62.41 > ECE-R10 > EN 61000-4-11 > EN 61000-4-29 > EN 61000-4-4 > EN 61000-4-5 > EN 61000-4-8
More informationReport No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for
Report No.: 9A042401C2 Page 1 of 36 EN 50121-4: 2006 Product: Industrial IEEE 802.11a/b/g Dual-RF AP/Bridge/Client Trade Name: MOXA Model Number: AWK-5222 Prepared for MOXA Inc. Fl.4, No.135, Lane 235,
More informationCurrent clamps for AC current
Current clamps for AC current Y series The Y series clamps are designed to be both rugged and versatile whilst remaining easy to use. The jaws are designed so that the clamps can be hooked onto cables
More informationEMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.
EMC TEST REPORT REPORT NO. : RM110613E07 MODEL NO. : M-R0027 RECEIVED : June 13, 2011 TESTED : June 17, 2011 ISSUED : June 22, 2011 APPLICANT : LOGITECH FAR EAST LTD. ADDRESS : #2 Creation Rd. 4, Science-Based
More informationTEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.
TEST REPORT Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015 Issued for: Shenzhen Flus Technology Co., Ltd 3rd Floor, Lantian Building,
More informationMulti-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi
Features Special relay for alternating loads, for applications with pumps, compressors, air conditioning or refrigeration units 2 independent NO output, 12 A 4 functions 2 independent control signals,
More informationEMC VERIFICATION SUMMARY Report No.: SZHH
EMC VERIFICATION SUMMARY Toy ITE Others Additional Models: 0801 to 0899 INCLUSIVE, 0804, 0804W, 0805, 0806, 0807, 0808, 0809, 0811, 0811W, 0812, 0813, 0814,0815, 0816, 0817,0817 ROOM 619, 6/F. PENINSULA
More informationREK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual
REK 50 protection of a synchronous machine User s Manual REK 50 X 0 9 8 7 6 5 4 0 V 00 V 0 V 5 6 7 Ordering No: REK 50-AA Uau = 00/0 Vac Un = 48 V Serial No: fn = 50/60 Hz Uec = ma 600 Vdc MRS 75587-MUM
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer IN 1000-S N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)
More informationPassive Current Transducers for Sinusoidal Alternate Currents From A/0...5 A MCR-SLP-1/5-UI-0(-SW)
Passive Current Transducers for Sinusoidal Alternate Currents From 0... A/0...5 A (-SW) Passive current transducer without power supply Measuring range A and 5 A AC, reconnectable Available with threshold
More informationAC/DC current clamps (1/2) E N series
AC/DC current clamps The clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A. These clamps' narrow, elongated design makes them ideal areas
More informationEnergy Management Energy Meter Type EM110
Energy Management Energy Meter Type EM110 Single phase energy meter Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Electro-mechanical display Energy readout on display: 6+1 digit
More informationElectromagnetic Compatibility
Electromagnetic Compatibility Introduction to EMC International Standards Measurement Setups Emissions Applications for Switch-Mode Power Supplies Filters 1 What is EMC? A system is electromagnetic compatible
More informationEMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.
Report No.: UNI2016121702ER-01 Page 1 / 30 ShenZhen KY Technology Co.,Ltd EMC REPORT Prepared For: ShenZhen KY Technology Co.,Ltd Product Name: Smart bracelet No.369, BaoTian 1st RD, TieGang Industrial
More informationSWT 3000 Teleprotection technical data siemens.com
Power network telecommunication SWT 3000 Teleprotection technical data siemens.com Sustainable success for high-voltage power networks The SWT 3000 Teleprotection system has been the first choice for reliable
More information400 (±2,5 V/ V/ ,3% V4A
LVDT Inductive Position Transducer - Hydraulic Series Series Hydraulic position measurement in hydraulic cylinders of machine controls ranges 10...300 mm temperature -40...+150 C (sensors) 0...+60 C (external
More informationHarmonizing the ANSI-C12.1(2008) EMC Tests. Harmonizing the ANSI-C12.1(2008) EMC Tests
Harmonizing the ANSI-C12.1(2008) EMC Tests Subcommittee 1 (Emissions) Subcommittee 5 (Immunity) Joint Task Force on C12.1 June 17, 2013 1 The Accredited Standards Committee C63 presents Harmonizing the
More informationWIRELESS INSULATOR POLLUTION MONITORING SYSTEM
SYSTEM OVERVIEW Pollution monitoring of high voltage insulators in electrical power transmission and distribution systems, switchyards and substations is essential in order to minimise the risk of power
More informationTABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT
ELECTROMAGNETIC COMPLIANCE TEST REPORT For Electric nail art drill Model Name: HBS-021, HBS-278, HBS-288, HBS-530, HBS-540 Brand Name: Date of Issue: May 7, 2011 Prepared For Houbos Hardware & Electrical
More information87 Series - Modular timers 5-8 A. Features
87 eries - Modular timers 5-8 A Features 87.01 87.02 Mono-function and multi-function timer range mm wide 87.01-1 Pole - Multi-function and multi-voltage 87.02-2 Pole - Multi-function and multi-voltage,
More informationIRIG-B Interface (De-modulated) External clock synchronization signal IRIG format B00X
P847B&C Technical Data Sheet INTERFACES IRIG-B (De-modulated) Use Standard Connector Cable type Isolation Input signal Input impedance at dc Accuracy IRIG-B Interface (De-modulated) External clock synchronization
More informationTEST REPORT. Table of Contents
Page:2 of 35 Table of Contents 1. DOCUMENT POLICY AND TEST STATEMENT... 4 1.1 DOCUMENT POLICY...4 1.2 TEST STATEMENT...4 1.3 EUT MODIFICATION...4 2. DESCRIPTION OF EUT AND TEST MODE... 5 2.1 GENERAL DESCRIPTION
More informationP331-2 set ESD generator (IEC )
User manual Probe set set ESD generator (IEC 61000-4-2) Copyright January 2017 LANGER GmbH 2017.01.09 User manual Table of contents: Page 1 ESD generator (IEC 61000-4-2) 3 1.1 Design and function of the
More information