Notes B

Size: px
Start display at page:

Download "Notes B"

Transcription

1

2 Notes B 2

3 TABLE OF CONTENTS TEKS Fastener Features...B 4 TEKS Self Drilling Fasteners...B 5 Light Duty Steel-To-Steel Applications...B 6 Medium Duty Steel-To-Steel Applications...B 8 Heavy Duty Steel-To-Steel Applications...B 11 Low Profile Architectural Metal Roof Clip Fasteners...B 14 Wood-to-Metal Fasteners...B 16 TEKS with Bonded Washer...B 19 Dekstrip Expandable Edged Flashing...B 22 Dektite and Retrofit Dektite...B 25 TAPCON Concrete and Masonry Anchors...B 28 TAPCON Ceiling Anchor...B 32 E-Z Drywall Anchors...B 34 Rock-On and Backer-On Fasteners...B 36 Gridmate BR Plastic Insulation Fasteners...B 38 B 3

4 TEKS Fastening Features FEATURES Head Threads Pilot Section (When Necessary) Flute Point HEAD Proper head style choice will ensure stability during driving, proper clamping and desired finished appearance. THREAD FORM AND DIAMETER The correct choice of thread form and diameter optimizes low installation torque with high pullout strength. PILOT SECTION The unthreaded portion of the point assures the drilling of the steel is completed before the threads begin tapping into the drilled hole. POINT The point is designed to efficiently remove material and precisely size the hole for the thread. FINISH Platings and coatings provide lubricity during drilling and tapping as well as corrosion resistance. FASTENER DESCRIPTION AND BREAKDOWN EXAMPLE x 3/4" HWH Teks/3 Nominal Screw Size Threads Per Inch Screw Length Head Style Drill Point Type Nominal Screw Sizes Thread Decimal Diameter Equivalent #6.140 #7.150 #8.160 #9.180 # # # # # /4.250 # Steel Gauge Chart Common Decimal Eq. Sheet Steel Gauges Inches MM / / / / Material Thickness (Inches) Screw Size Point 2.4mm mm 2.4mm mm 2.4mm mm 2.50mm mm Drill and Tap Material Thickness Chart 5.3mm mm 4.17mm mm 5.3mm mm 5.3mm mm 6.36mm mm 6.36mm mm 9.51mm mm 12.72mm mm 12.72mm mm #10 #12 1/4 #8 #12 #10 #12 1/4 #12 1/4 #12 #12 1/4 Teks/1 Teks/2 Teks/3 Teks/4 Teks/4.5 Teks/5 *Drill & tap capacities may vary with special feature designs. Refer to product reports for specifics. B 4

5 TEKS Self-Drilling Fasteners Preferred Most by Electrical, Decking, HVAC and Metal Building Contractors DESCRIPTION/ADVANTAGES Light Duty Steel-To-Steel Applications SPECIFICATIONS Diameter / 8-18 Thread Form Head Styles TEKS Self-Drilling Fasteners Sharp convex drill point has precise cutting edges to improve drill performance with less effort. Non-walking point provides fast material engagement. Unique point to thread design extrudes the metal preventing stripout. Point to thread design maximizes pullout performance and minimizes backout. Three head styles available to handle various applications. Climaseal finish provides excellent corrosion resistance Hex Washer Head Socket Pan Head Modified Truss Head (HWH) (SP) (MTH) Drill Point Teks 2 Teks 3 Finish Type Kesternich Results Salt Spray Results (DIN 50018, 2.OL) (ASTM B117) Electro-zinc (EZ) 3 cycles - 5% or less red rust 48 hours - 5% or less red rust Climaseal Coating (CL) 30 cycles - 10% or less red rust 1000 hours - 10% or less red rust Climaseal + Coating (CL+) Meets or exceeds Kesternich and Salt Spray Results of Climaseal Coating (CL) INSTALLATION INSTRUCTIONS 1. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 4 amps and have a RPM range of Adjust the screwgun nosepiece to properly seat the fastener. 3. New magnetic sockets must be correctly set before use. Remove chip build-up as needed. 4. The fastener is fully seated when the head is flush with the work surface. 5. Overdriving may result in torsional failure of the fastener or stripout of the substrate. 6. The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. B 5

6 TEKS Light Duty Steel-To-Steel Applications Stitch roof deck and wall panel sidelaps. HVAC, electrical trim accessories to steel framing. Residential steel frame construction. Brick ties to steel framing. Track to stud and stud splicing. Hat channel to stud. APPROVALS/LISTINGS Factory Mutual (J.I. 2 X 9A2 AM) ICC - ESR 1976 SELECTION CHART TEKS Fasteners PART REFERENCE DESCRIPTION Finish: Electro-Zinc Plating. HEAD STYLE DRILL POINT DRILL & TAP CAPACITY MAX. MATERIAL ATTACHMENTS BOX QTY P/A X PAK QTY PAK QTY 2240 X 2240 X 8-18 x 1/2" #2 SP # ,000 1, x 1/2" MTH # , X 2280 X 8-18 x 5/8" #2 SP # ,000 1, X 2330 X 8-18 x 3/4" #2 SP # ,000 1, X 2360 X A 8-18 x 1" #2 SP # , X 2220 P X 8-18 x 1/2" 1/4" HWH # ,000 1, X 2310 X A 8-18 x 3/4" 1/4" HWH # ,000 1, A 8-18 x 1" 1/4" HWH # ,000 P Available in P/A PAK TEKS Fasteners PART REFERENCE X Available in X PAK DESCRIPTION Finish: Electro-Zinc Plating. HEAD STYLE DRILL POINT DRILL & TAP CAPACITY MAX. MATERIAL ATTACHMENTS BOX QTY P/A X PAK QTY PAK QTY - HVAC, electrical trim accessories to steel framing - Residential steel frame construction - Track to stud - Hat channel to stud - Stud splicing 2480 X 2480 X x 3/4" #2 SP # , Clips, duct straps, brick 2490 X 2490 X x 1" #2 SP # , ties or accessories to steel framing 2495 X 2495 X x 1-1/4" #2 SP # , X 2400 X x 1/2" 5/16" HWH # ,000 1, P X 2460 P X x 3/4" 5/16" HWH # , A X 2510 A X x 1" 5/16" HWH # , P Available in P/A PAK X Available in X PAK TEKS Fasteners PART REFERENCE DESCRIPTION Finish: Climaseal Coating. HEAD STYLE DRILL POINT DRILL & TAP CAPACITY MAX. MATERIAL ATTACHMENTS BOX QTY x 3/4" 5/16" HWH # ,000 - Clips, duct straps, brick ties or x 1-1/2" 5/16" HWH # ,000 accessories to steel framing 2220CL 2220CL 8-18 X 1/2" 1/4" HWH # ,000 + (CL+) Coating B 6

7 PERFORMANCE TABLES Sheet Steel Gauges TEKS Light Duty Steel-To-Steel Applications GAUGE NO Nominal Decimal Equivalent (Inch) Pullout Values (Average Lbs. Ultimate) FASTENER STEEL GAUGE (Lbs.) DIA. PT # # / Shear Values (Average Lbs. Ultimate) FASTENER STEEL GAUGE (Lapped) DIA. PT # # / Fastener Values FASTENER (Dia-tpi) TENSILE (Lbs. Min) SHEAR (Avg. Lbs. Ultimate) TORQUE (Min. in Lbs.) The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes. B 7

8 TEKS Self-Drilling Fasteners The Best Point Ever for Speed and Consistency DESCRIPTION/ADVANTAGES Medium Duty Steel-To-Steel Applications TEKS Self-Drilling Fasteners SPECIFICATIONS Diameter / Thread Form /4-14 Point has precise cutting edges to improve drill performance with less effort. Non-walking point provides fast material engagement. Point to thread design maximizes pullout performance and minimizes backout. Drills and taps in the broadest range of applications. Climaseal finish provides excellent corrosion resistance and lower tapping torque. Head Style Hex Washer Head (HWH) Drill Point Teks 2 Teks 3 Finish Type Kesternich Results Salt Spray Results (DIN 50018, 2.OL) (ASTM B117) Electro-zinc (EZ) 3 cycles - 5% or less red rust 48 hours - 5% or less red rust Climaseal Coating (CL) 30 cycles - 10% or less red rust 1000 hours - 10% or less red rust Climaseal + Coating (CL+) Meets or exceeds Kesternich and Salt Spray Results of Climaseal Coating (CL) INSTALLATION INSTRUCTIONS 1. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have a RPM range of Adjust the screwgun nosepiece to properly seat the fastener. 3. New magnetic sockets must be correctly set before use. Remove chip build-up as needed. 4. The fastener is fully seated when the head is flush with the work surface. 5. Overdriving may result in torsional failure of the fastener or stripout of the substrate. 6. The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. B 8

9 TEKS Medium Duty Steel-To-Steel Applications APPROVALS/LISTINGS Roof deck to steel framing. Wall panel to girt. Duct work to steel framing. Accessories to steel framing Clip to steel framing. Retrofit framing. Factory Mutual (J.I. 2 X 9A2 AM) ICC - ESR 1976 DRILL POINTS Teks 2 Teks 3 SELECTION CHART TEKS Fasteners PART REFERENCE DESCRIPTION Finish: Climaseal Coating. HEAD STYLE DRILL POINT DRILL & TAP CAPACITY MAX. MATERIAL ATTACHMENTS BOX QTY P PAK QTY x 3/4" 5/16" HWH # ,000 - Duct work to steel framing P x 1" 5/16" HWH # , x 1-1/4" 5/16" HWH # , x 1-1/2" 5/16" HWH # , x 2" 5/16" HWH # , /4-14 x 3/4" 3/8" HWH # , /4-14 x 1" 3/8" HWH # , /4-14 x 1-1/4" 3/8" HWH # , /4-14 x 1-1/2" 3/8" HWH # , P 1/4-14 x 2" 3/8" HWH # , /4-14 x 2-1/2" 3/8" HWH # , /4-14 x 3" 3/8" HWH # , /4-14 x 4" 3/8" HWH # P Available in P PAK + (CL+) Coating - Accessories to steel framing - Clip to steel framing - Duct work to steel framing - Accessories to steel framing - Clip to steel framing TEKS Fasteners PART REFERENCE DESCRIPTION Finish: Electro-zinc Plating. HEAD STYLE DRILL POINT DRILL & TAP CAPACITY MAX. MATERIAL ATTACHMENTS x 3/4" 5/16" HWH # ,000 BOX QTY A/X PAK QTY A A x 1" 5/16" HWH # , A A x 1-1/2" 5/16" HWH # , A A x 2" 5/16" HWH # , Duct work to steel framing - Accessories to steel framing - Clip to steel framing /4-14 x 3/4" 3/8" HWH # , A A 1/4-14 x 1" 3/8" HWH # , A A 1/4-14 x 1-1/4" 3/8" HWH # , A A 1/4-14 x 1-1/2" 3/8" HWH # , /4-14 x 2" 3/8" HWH # , /4-14 x 3" 3/8" HWH # ,000 A Available in A PAK X Available in X PAK B 9

10 TEKS Medium Duty Steel-To-Steel Applications PERFORMANCE TABLES Sheet Steel Gauges GAUGE NO Nominal Decimal Equivalent (Inch) Pullout Values (Average Lbs. Ultimate) FASTENER Fastener Values FASTENER (Dia-tpi) TENSILE (Lbs. Min) SHEAR (Avg. Lbs. Ultimate) TORQUE (Min. in Lbs.) / STEEL GAUGE (Lbs.) DIA. PT /16 # / Shear Values (Average Lbs. Ultimate) FASTENER STEEL GAUGE (Lapped) DIA. PT # / The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes. B 10

11 TEKS Self-Drilling Fasteners First in Performance!! Over 30 Years of Consistent Drilling DESCRIPTION/ADVANTAGES Heavy Duty Steel-To-Steel Applications THE ORIGINAL SELF-DRILLERS FOR HEAVY DUTY TEKS Self-Drilling Fasteners SPECIFICATIONS Diameter / Thread Form 1/4-28 Unique double fluted point has precise cutting edges to improve drill performance in 1/4" thru 1/2" steel. Engineered for fast drilling and smooth tapping with less effort. Climaseal finish provides excellent corrosion resistance and lower tapping torque. Attachments up to 7.2" of material including 1/2" steel. 1/4" Diameter has notched threads to reduce tapping torque. Head Styles Hex Washer Head (HWH) Drill Point Teks 4 Teks 5 Finish Type Kesternich Results Salt Spray Results (DIN 50018, 2.OL) (ASTM B117) Climaseal Coating (CL) 30 cycles - 10% or less red rust 1000 hours - 10% or less red rust INSTALLATION INSTRUCTIONS 1. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have a RPM range of (Maximum 1800 RPM is recommended for Teks 5 fasteners) 2. Adjust the screwgun nosepiece to properly seat the fastener. 3. New magnetic sockets must be correctly set before use. Remove chip build-up as needed. 4. The fastener is fully seated when the head is flush with the work surface. 5. Overdriving may result in torsional failure of the fastener or stripout of the substrate. 6. The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. B 11

12 TEKS Heavy Duty Steel-To-Steel Applications APPROVALS/LISTINGS Metal deck to structural steel or bar joist. Clips to structural steel or bar joist. Liner panels to structural steel or bar joist. Accessories to structural steel or bar joist. Longer length fasteners can be used in retrofit clip and sheet applications. Factory Mutual (J.I. 2 X 9A2 AM) ICC - ESR 1976 DRILL POINTS Teks 4 Teks 5 SELECTION CHART TEKS Fasteners PART REFERENCE Finish: Climaseal Coating. DESCRIPTION HEAD STYLE DRILL POINT DRILL & TAP CAPACITY MAX. MATERIAL ATTACHMENTS x 1-1/2" 5/16" HWH # ,000 BOX QTY P/X PAK QTY 1650 P P x 7/8" 5/16" HWH # , P P x 1-1/4" 5/16" HWH # , X X x 1-1/2" 5/16" HWH # , P P x 2" 5/16" HWH # , x 1-1/4" 5/16" HWH # , /4-28 x 3" 5/16" HWH # , /4-28 x 4" 5/16" HWH # /4-28 x 5" 3/8" HWH # /4-28 x 6" 3/8" HWH # /4-28 x 8" 3/8" HWH # P Available in P PAK B Available in X PAK Material Thickness (Inches) Screw Size Point 2.4mm 2.4mm 2.4mm Drill and Tap Material Thickness Chart 2.5mm mm mm.91mm 4.17mm 5.3mm 5.3mm mm.91mm.91mm 6.36mm 6.36mm mm mm 3.18mm 3.18mm 3.18mm 3.18mm mm.45mm.45mm #10 #12 1/4 #8 #12 #10 #12 1/4 #12 1/4 #12 #12 1/4 Teks/1 Teks/2 Teks/3 Teks/4 Teks/4.5 Teks/5.125 *Drill & tap capacities may vary with special feature designs. Refer to product reports for specifics. - Metal deck, clips, linear panels or accessories to structural steel or bar joist - Retrofit clip and sheet applications 12.72mm 12.72mm B 12

13 PERFORMANCE TABLES Sheet Steel Gauges TEKS Heavy Duty Steel-To-Steel Applications GAUGE NO Nominal Decimal Equivalent (Inch) Pullout Values (Average Lbs. Ultimate) Fastener Values FASTENER (Dia-tpi) FASTENER PT TENSILE (Lbs. Min.) STEEL GAUGE (Lbs.) DIA. PT /16 1/4 # / Shear Values (Average Lbs. Ultimate) FASTENER STEEL GAUGE (Lapped) DIA. PT /8 1/4 # / SHEAR (Avg. Lbs. Ultimate) TORQUE (Min. in Lbs.) / NOTE: Teks fasteners are not categorized as structural bolts. Proper design criteria and strengths must be used for satisfactory application. The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes. B 13

14 TEKS Self-Drilling Fasteners Low Profile Architectural Metal Roof Clip Fasteners DESCRIPTION/ADVANTAGES Low Profile Architectural Metal Roof Clip Fastener INCORPORATES THE ITW EXCLUSIVE PHILLIPS SQUARE-DRIV ANTI-CAM-OUT SYSTEM #12 diameter utilizes the ITW exclusive Phillips Square-Driv with patented interlocking components system. - Excellent installation stability. - Extended bit driver life. - Keeps the driver securely mated to the fastener during installation. - Hands-free installation. Fasteners are finished with a corrosion resistant coating. Teks 3 fasteners are available with Gray Spex coating. Sharp convex drill point has precise cutting edges to improve drill performance with less effort. Low profile pancake head style ensures proper installation of metal roof panels. SPECIFICATIONS Diameter / Thread Form Head Styles Phillips Square-Driv Pancake (PSP) Drill Point Teks 3 Finish Type Kesternich Results Salt Spray Results (DIN 50018, 2.OL) (ASTM B117) Grey Specx 15 cycles - 5% or less red rust 300 hours - 10% or less red rust Low profile architectural metal roof clips to steel purlin. Low profile architectural metal roof clips to wood supports. INSTALLATION INSTRUCTIONS 1. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have a RPM range of Adjust the screwgun nosepiece to properly seat the fastener. 3. The fastener is fully seated when the head is flush with the work surface. 4. Overdriving may result in torsional failure of the fastener or stripout of the substrate. 5. The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. 6. New magnetic sockets must be correctly set before use. Remove chip build-up as needed. B 14

15 SELECTION CHART TEKS Low Profile Architectural Metal Roof Clip Fastener TEKS Fasteners Finish: Gray Spex Coating. PART REFERENCE DESCRIPTION HEAD STYLE DRILL POINT DRILL & TAP CAPACITY MAX. MATERIAL ATTACHMENTS BOX QTY x 1" #2 PSD # ,000 - Low profile architectural metal roof clip to steel purlin PERFORMANCE TABLES Sheet Steel Gauges GAUGE NO Nominal Decimal Equivalent (Inch) Pullout Values (Average Lbs. Ultimate) FASTENER STEEL GAUGE (Lbs.) DIA. PT # Shear Values (Average Lbs. Ultimate) FASTENER STEEL GAUGE (Lapped) DIA. PT 20 GAUGE 18 GAUGE 16 GAUGE 14 GAUGE # Fastener Values FASTENER (Dia-tpi) PT TENSILE (Lbs. Min.) SHEAR (Avg. Lbs. Ultimate) TORQUE (Min. in Lbs.) The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes. B 15

16 TEKS Wood to Metal Fasteners No Pre-Drilling, Fast, Efficient Attachment of Wood-To-Metal DESCRIPTION/ADVANTAGES Wood-To-Metal Applications TEKS Wood to Metal Self-Drilling Fasteners SPECIFICATIONS Diameter / Thread Form /4-20 Point has precise cutting edges to improve drill performance with less effort. Special winged fasteners ream a hole in wood preventing thread engagement during drilling. Wafer head design has a large bearing surface ideal for plywood. Flat head design countersinks and seats flush in wood. Gray Spex finish provides excellent corrosion resistance and lower tapping torque. Compatible with ACQ treated wood. Head Styles Socket Wafer Head (SW) Philips Flat Head (PFH) Drill Point Teks 3 Teks 4 Finish Type Kesternich Results Salt Spray Results (DIN 50018, 2.OL) (ASTM B117) Electro-zinc (EZ) 3 cycles - 5% or less red rust 48 hours - 5% or less red rust Grey Specx 15 cycles - 5% or less red rust 300 hours - 10% or less red rust INSTALLATION INSTRUCTIONS 1. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of Adjust the screwgun nosepiece to properly seat the fastener. 3. Worn or damaged bit tip should be replaced. 4. The fastener is fully seated when the head is flush with the work surface. 5. Overdriving may result in torsional failure of the fastener or stripout of the substrate. 6. The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. 7. All #10 diameter Winged parts must be driven into a minimum of 16 GA steel thickness. 8. All 1/4 and #12 diameter Winged parts must be driven into a minimum of 1/8" steel in order to break the wings consistently. B 16

17 TEKS Wood-To-Metal Applications DRILL POINTS Plywood roof and floor sheet to steel frames. 2 x 4 headers to steel frames. Plywood fascia to steel frames. Teks 3 Teks 4 Drill and Tap Material Thickness Chart Material Thickness (Inches) Screw Size Point 2.4mm 2.4mm 2.4mm mm mm mm.91mm 4.17mm 5.3mm 5.3mm mm.91mm.91mm 6.36mm 6.36mm mm mm.45mm.45mm #10 #12 1/4 #8 #12 #10 #12 1/4 #12 1/4 #12 #12 1/4 Teks/1 Teks/2 Teks/3 Teks/4 Teks/4.5 Teks/ mm 12.72mm mm 3.18mm 3.18mm 3.18mm 3.18mm *Drill & tap capacities may vary with special feature designs. Refer to product reports for specifics. SELECTION CHART TEKS Fasteners PART REFERENCE DESCRIPTION HEAD STYLE Finish: Electro-zinc Plating. Without Wings. DRILL POINT DRILL & TAP CAPACITY WOOD ATTACHMENT RANGE BOX QTY X PAK QTY A PAK QTY X X A x 1" #2 SW # /4"-1/2" 5, Plywood, mansard, fascia, X X x 1-1/4" #2 SW # /4"-3/4" 3, roofing, flooring to steel framing X Available in X PAK A Available in A PAK TEKS Fasteners PART REFERENCE DESCRIPTION Finish: Electro-zinc Plating. With Wings. HEAD STYLE DRILL POINT DRILL & TAP CAPACITY WOOD ATTACHMENT RANGE BOX QTY P PAK QTY X PAK QTY X P B x 1-1/2" #2 SW # /4"-1" 3, Plywood, 2 x 4 s to steel framing P P x 2" #3 SW # /4" - 1" 2, P x 2-1/2" #3 SW # /4"-1-1/2" 1, P P x 3" #3 SW # /4"-2" 1, P Available in P PAK X Available in X PAK B 17

18 TEKS Wood-To-Metal Applications SELECTION CHART TEKS Fasteners Finish: Gray Spex Coating. With Wings. PART REFERENCE DESCRIPTION HEAD STYLE DRILL POINT DRILL & TAP CAPACITY WOOD ATTACHMENT RANGE BOX QTY /4-20 x 3" #3 PFH # /4"-2" 1, x 2-1/4" #3 PFH # /4"- 1-3/8" 2, x 2-3/4" #3 PFH # /4"-2-5/8" 1,600 - Plywood, 2 x 4 s to steel framing PERFORMANCE TABLES Sheet Steel Gauges GAUGE NO Nominal Decimal Equivalent (Inch) Pullout Values (Average Lbs. Ultimate) FASTENER Fastener Values FASTENER (Dia-tpi) TENSILE (Lbs. Min) SHEAR (Avg. Lbs. Ultimate) TORQUE (Min. in Lbs.) / STEEL GAUGE Lbs.) DIA. PT /16 1/4 # # # / Shear Values (Average Lbs. Ultimate) FASTENER STEEL GAUGE (Lapped) DIA. PT /8 # # / The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes. B 18

19 TEKS with Bonded Washer For Weather-Tight Sealing of Roof and Wall Applications DESCRIPTION/ADVANTAGES Metal Roof and Wall Applications TEKS with Bonded Washer SPECIFICATIONS Diameter / Thread Form /4-14 1/4-28 Vulcanized bonding of washer eliminates separation of EPDM from the metal backing. Dual sealing bonded washer prevents leaks. Climaseal finish provides excellent corrosion resistance and lower tapping torque. Point has precise cutting edges to improve drill performance with less effort. Point to thread design maximizes pullout performance and minimizes backout. Head Styles Hex Washer Head with Bonded Washer(HWH) Washer Style Galvanized (G-90) Drill Point Teks 1 Teks 2 Teks 3 Teks 4 Teks 5 Finish Type Kesternich Results Salt Spray Results (DIN 50018, 2.OL) (ASTM B117) Climaseal Coating (CL) 30 cycles - 10% or less red rust 1000 hours - 10% or less red rust Climaseal + Coating (CL+) Meets or exceeds Kesternich and Salt Spray Results of Climaseal Coating (CL) INSTALLATION INSTRUCTIONS 1. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screw gun should be a minimum of 6 amps and have an RPM range of New magnetic sockets must be correctly set before use Remove chip build-up as needed. 3. Adjust the screwgun nosepiece to properly seat the fastener. 4. Overdriving may result in torsional failure of the fastener or stripout of the substrate. 5. The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. B 19

20 TEKS Metal Roof and Wall Applications DRILL POINTS Roof panels to purlin or bar joist. Wall panels to girt. Mansard panel to structural. Teks 1 Teks 2 Teks 3 Teks 4 Teks 5 Drill and Tap Material Thickness Chart PROPERLY SEATED WASHERS Underdriven Correctly Driven Overdriven SELECTION CHART TEKS w/bonded Washer PART REFERENCE DESCRIPTION Finish: Climaseal Coating. HEAD STYLE WASHER DIAMETER DRILL POINT DRILL & TAP CAPACITY MAX. MATERIAL ATTACHMENTS x 3/4" 5/16" HWH 9/16" # , W x 3/4" 5/16" HWH 9/16" # , W x 1" 5/16" HWH 9/16" # , W x 1-1/2" 5/16" HWH 9/16" # , W x 2" 5/16" HWH 9/16" # , W /4-14 x 7/8" 5/16" HWH 9/16" # , W /4-14 x 1" 3/8" HWH 9/16" # , W 1/4-14 x 1-1/2" 3/8 HWH 9/16 # , W /4-14 x 2" 3/8" HWH 9/16" # , W x 1-1/4" 5/16" HWH 9/16" # , W x 1-1/2" 5/16" HWH 9/16" # , W x 2" 5/16" HWH 9/16" # , /4-28 x 3" 5/16" HWH 9/16" # , /4-28 x 4" 5/16" HWH 9/16" # /4-28 x 5" 3/8" HWH 3/4" # (CL+) Coating Material Thickness (Inches) Screw Size Point 2.4mm 2.4mm 2.4mm mm mm mm.91mm 4.17mm 5.3mm 5.3mm mm.91mm.91mm mm.45mm.45mm #10 #12 1/4 #8 #12 #10 #12 1/4 #12 1/4 #12 #12 1/4 Teks/1 Teks/2 Teks/3 Teks/4 Teks/4.5 Teks/5 *Drill & tap capacities may vary with special feature designs. Refer to product reports for specifics. BOX QTY 6.36mm 6.36mm mm mm 3.18mm 3.18mm 3.18mm 3.18mm - Brick tie to steel framing - Mansard panel to steel framing - Roof panel to purlin - Stitch roof 12.72mm 12.72mm B 20

21 PERFORMANCE TABLES Sheet Steel Gauges GAUGE NO Nominal Decimal Equivalent (Inch) Pullout Values (Average Lbs. Ultimate) FASTENER Fastener Values FASTENER (Dia-tpi) TENSILE (Lbs. Min.) SHEAR (Avg. Lbs. Ultimate) TORQUE (Min. in Lbs.) / / STEEL GAUGE (Lbs.) DIA. PT /16 1/4 # #12 #12 1/4 Shear Values (Average Lbs. Ultimate) FASTENER TEKS Metal Roof and Wall Applications STEEL GAUGE (Lapped) DIA. PT /8 1/4 # #12 #12 1/ The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes. B 21

22 DEKSTRIP Expandable Edged Flashing Stretches to Any Shape, Seals and Stays DESCRIPTION/SUGGESTED SPECIFICATIONS Pipe Flashing Applications DEKSTRIP is a flexible neoprene product that is completely chemical resistant. It has an aluminum bar embedded in it to form & follow the various corrugations of your roof. ADVANTAGES Wraps around almost any profile Paintable after installation TPE has a continuous service temperature range of -50 C to +115 C 20 year warranty Serpentine edges stretch up to 25% for added length Great for large round pipes Handles vibration & expansion DEKSTRIP B 22

23 DEKSTRIP Expandable Edged Flashing INSTALLATION INSTRUCTIONS Large square & round ducts & penetrations BASIC Chimneys Skylights Parapet Flashing Expansion Joints Stepped Roof Dissimilar roof profiles Transition wall 1. Snap a chalk line to provide a guide for applying sealant. Gambrel roof Flash between dissimilar materials 2. Apply a continuous bead of sealant along chalk line. SPECIFICATIONS Material Grey TPE 3. Position top edge of Dekstrip over seal bead and install Buildex fasteners at 1-1/2" maximum intervals on top edge. Repeat steps 1, 2, and 3 for the bottom edge. Base Kit Contents Dekstrip material 1" x 4' Aluminum termination strip 3" x 2' Splice tape 4. Apply additional sealant to both fastened edges for maximum weather-tight sealing. B 23

24 DEKSTRIP Expandable Edged Flashing INSTALLATION INSTRUCTIONS SPLICING MATERIALS NEEDED: Leather Gloves Heat Gun 3" x 2' splice tape Shears or scissors 1. Apply splice tape to Dekstrip. 2. Position second Dekstrip over tape & press in place. 3. Apply heat and press firmly to seal edges. DETAILED INSTRUCTIONS 1. Cut splice tape (supplied in Dekstrip carton) to the width needed and remove clear film from one side of the tape. Lining up the edges, press the tape firmly onto the Dekstrip to remove air pockets. 2. Remove remaining film from tape. Apply second piece of Dekstrip over tape and press firmly. 3. Apply heat over spliced area for 1-2 minutes while applying firm pressure over entire spliced area to ensure adhesion. 4. Turn material over and repeat step 3. JOINING ENDS AROUND ROUND PIPES DETAILED INSTRUCTIONS 1. Cut splice tape to length, remove film from one side and apply to Dekstrip. 2. Remove film from top of splice tape. 3. Overlap top piece of Dekstrip and press onto tape. 4. Fold termination strip in half, cut to width, and slide over spliced area and apply to Dekstrip. 5. Fasten through top of termination strip, Dekstrip, and back of strip with Scots fasteners or rivets. 6. Apply sealant to all seams SELECTION CHART DEKSTRIP Expandable Edged Flashing PART REFERENCE DESCRIPTION WEIGHT FASTENERS NEEDED (1-1/2" O.C.) " x 75' 31 lbs " x 75' 38 lbs " x 50' 30 lbs. 800 B 24

25 Dektite and Retrofit Dektite The Original Flexible Pipe Flashing System with a 20 Year Warranty. Standard Dektite DESCRIPTION/SUGGESTED SPECIFICATIONS Pipe Flashing Applications Dektite Will not crack or break. Dekite can be installed over or between the ribs of standard panels. Generally no sealant is required where the Dektite collar provides a compression fit around the pipe. Standard Dektite ADVANTAGES Retrofit Dektite Made of long life, flexible, weatherproof gray EPDM rubber or red silicone. Flexible, corrosion resistant aluminum base conforms to any panel configuration. EPDM and silicone will not crack or break. Pipe diameter markings are clearly indicated for accurate fitting. Designed for 1/4" to 18" diameter pipes. Pleated cone adjusts to any roof pitch and allows for complete flexibility. Step Design vs Dektite No size markings on step design. Dektite underside rib height is 54% lower than step design, resulting in better drainage % -35.1% Retrofit Dektite makes difficult installations a breeze! Wraps around existing or difficult to access pipes. Snaps together in seconds. The built-in crimp means no loose clips or rivets. Grips tight and stays tight. The supple aluminum base conforms to metal profiles One piece construction is easy to install. EPDM has a continuous service temperature range of -53 C to +121 C. Silicone has a continuous service temperature range of -40 C to +176 C Proven resistance to ozone and ultra-violet light. Thickness of the cone, particularly at stress points, considerably impacts on the life span of the flashing. Dektite is up to 66% thinker in some areas over the competition. Step design has exposed corner angles that become vulnerable to degradation when stretched. Step product is WT% thinner compound in critical areas. -54% Retrofit Dektite PHYSICAL PROPERTIES Product Comparison Dektite with Silicone Needs loose clips to join ends. Needs band to seal pipe. Needs sealant applied to base, seam & pipe seam join. Fully integrated waterproof seam joint Seals by strong compound & good design Only needs a sealant on roof and top of seam -24.8% % 3.30mm 7.65mm mm -23.4% 2.57mm 3.171mm -.28% 2.47mm 2.54mm Other Retrofit -12.5% 3.53mm 3.97mm Dektite Retrofit Dektite with wires PRODUCT COMPARISON B 25

26 Dektite and Retrofit Dektite Plumbing Heating Air Conditioning Electrical and Exhaust Vents INSTALLATION INSTRUCTIONS Dektite Cut Dektite at appropriate pipe diameter marking. 2. Slide Dektite flashing down over pipe. 3. Apply sealant on underside of flexible aluminum base. 4. Press Dektite base into contours of panel configuration. 5. Fasten Dektite to surface with Buildex Scots self-drilling fasteners. Apply additional sealant around base if desired. Notes: Dekite can be installed over or between the ribs of standard panels. Can be installed between the rib sections of a Standing Seam Roofs or Architectural Panel. Do Not install over the rib section of the SSR or Architectural Panel ribs. Generally no sealant is required where the Dektite collar provides a compression fit around the pipe. However, some metal pipes and flues include a seam which may require a local application of sealant at the point where the Dektite colla crosses the seam. Retrofit Dektite SPECIFICATIONS Pipe Diameter Ranges 1/4" to 18" Dektite 3/4" to 10" Retrofit Dektite 1/4" to 18" Silicone Materials EPDM Standard and Retrofit Silicone High Temperature Replace with Recommend Sealant: Flexible, Polyurethane-based elastomeric Sealant Begin cutting opposite of the mechanical locking joiner. Cut through the joiner with tin snips. 2. Wrap Retrofit Dektite around the pipe. Engage the top section of the joiner first, then proceed down until joiner is completely engaged. 3. Crimp joiner tightly, starting at the top by squeezing joiner fingers with pliers. 4. Apply sealant to the underside of the ribbed aluminum base. Press Retrofit Dektite against contours of the panel configuration. 5. Attach Retrofit Dektite to the panel with SCOTS self-drilling screws. Screws should be spaced as necessary to avoid gaps between the base and the panel. 6. Apply additional sealant around the top of the Dektite, near the mechanical locking joiner seam. B 26

27 Dektite and Retrofit Dektite SELECTION CHART Dektite Flashing PART REFERENCE DESCRIPTION PIPE OUTSIDE DIAMETER DEKTITE BASE DIAMETER DEKTITE HEIGHT #1 EPDM 1/4" - 2" 4-3/4" 3" #2 EPDM 1-3/4" - 3-1/4" 6-1/4" 4" #3 EPDM 1/4" - 4" 7-3/4" 4" #4 EPDM 3" - 6" 9-1/4" 5" #5 EPDM 4" - 7" 10-3/4" 5" #6 EPDM 5" - 9" 12-1/2" 6" #7 EPDM 6" - 11" 14-1/2" 6" #8 EPDM 7" - 13" 16-1/2" 6" #9 EPDM 10" - 18" 25-3/8" 8" #3 Silicone 1/4" - 4" 7-3/4" 4" #5 Silicone 4" - 7" 10-3/4" 5" #8 Silicone 7" - 13" 16-1/2" 6" #9 Silicone 10" - 18" 25-3/8" 8" 2 Note: When used on roofs where pitch is steeper than 20 degrees, or when used on deep ribbed profile roof panel (1-1/2" deep corrugation or more), consider using next larger size Dektite that will accommodate the same pipe diameter. Flexible, Polyurethane-based elastomeric Sealant. Recommended Fastener: 1/4-14 x 7/8" Scots Teks /1, part number BOX QTY Retrofit Dektite PART REFERENCE DEKTITE SIZE PIPE OUTSIDE DIAMETER DEKTITE BASE DIAMETER DEKTITE HEIGHT EPDM 3/4" - 2-3/4" 6-3/10" 3-1/2" EPDM 2" - 7-1/4" 10-3/4" 5-3/5" EPDM 3-1/4" - 10" 14-1/2" 5-4/5" 5 BOX QTY PERFORMANCE TABLE Dektite Flashing ASTM METHOD TEST DESCRIPTION SPECIFICATION TEST RESULTS D412 Tensile Strength (min. psi rating) 1450 psi min psi D412 Ultimate Elongation (%) 350 min. 535 D1171 Resistance to Ozone-min. rating 100 (no cracks) Passed D673 Heat Aging - 70 hrs. at 100 C Change in Hardness (points) Change in Tensile Strength (%) Change in Elongation (%) ± 15 max. ± 30 max. ± 50 max ASTM METHOD D2137 D624 TEST DESCRIPTION Low Temperature Brittleness- 3 mins. at -40 C Tear Resistance Die C (min.) per inch of width min. SPECIFICATION Non-brittle 125 pounds per inch of width TEST RESULTS Passed 130 pounds U.L. 94 Flame Resistance U.S. 94 H.B. Passed B 27

28 DESCRIPTION/ADVANTAGES TAPCON Concrete and Masonry Anchors Light-To-Medium Duty Masonry Applications The original masonry anchor that cuts its own threads into concrete, brick, or block. Maximum performance is achieved because the Tapcon Anchor, the Condrive Installation Tool, and the carbide-tipped Tapcon Drill Bits are designed to work as a system. It is essential to use the Condrive tool and the correct drill bit to assure consistent anchor performance. ADVANTAGES Fast installation... drill a hole... drive an anchor. Packaged with one Tapcon close tolerance masonry drill bit per 100 anchors. Also available in bulk packaging. Available in 3/16" diameter up to 4" in length and 1/4" diameter up to 6 in length. Compatible for use in ACQ treated wood. Tapcon Anchors Replaces small diameter expansion anchors, plugs and screws in light to medium duty applications. No need to pre-spot holes... and no inserts are required. Reversible and removable... can be installed close to an edge. Hex Head style on Tapcon Anchors is available for majority of fixture anchoring needs Climaseal Coating is standard on all Tapcon anchors to provide extended corrosion resistance Phillips Flat Head style is available when flush seating is necessary in countersink applications Advanced Threadform cuts into masonry materials for greater pullout values Lengths of Tapcon Anchors range from 1-1/4" to 4" in 3/16" and up to 6" in 1/4" diameters. Nail-Type Point guides the anchor into the pre-drilled hole. Excellent for wood to concrete applications SPECIFICATIONS Diameter 3/16" and 1/4" Thread Form Advanced Threadform Technology Head Style Point Type Finish Flat and Hex Head Nail Blue Climaseal B 28

29 Tapcon Concrete and Masonry Anchors APPROVALS/LISTINGS Electrical junction boxes and conduit clips to masonry. Wood headers and furring strips to masonry HVAC strapping to masonry. Plywood backer boards to masonry. Exterior insulation systems to masonry. Miami Dade County Product Control Approved RR25644 ICC-ESR 1671 Masonry ICC-ESR 2202 Concrete City of Los Angeles INSTALLATION STEPS Read instructions before using (installation)! WARNING: If there are any questions concerning proper installation, applications or appropriate use of this product, please call our Technical Services Department at Failure to follow these instructions can result in serious personal injury. INSTALLATION TOOL GUIDELINES Tapcon Condrive Pro Installation Kit A one-tool system engineered to work with all impact drivers, rotary hammers and hammer drills, the Tapcon Pro Installation Kit can drill and drive. The Condrive is designed to speed up anchor installation and enhance jobsite productivity. It features recessed hex drivers designed to significantly reduce over-torquing, head snapping and strip outs, allowing PROs to anchor with confidence and efficiency the first time, every time. PREPARATION 1. Place correct Tapcon drill bit in drill adapter and tighten set screw with hex key (included). For rotary hammer begin at Step Secure drill adapter into 3/8" 1/2" chuck of hammer drill or into 1/4" impact hammer 3. Attach appropiate hex driver or Phillips bit to end of sleeve. DRILL 4. Drill hole 1/4" deeper than depth of anchor embedment. (Min. embedment 1"). Remove dust from hole. SLIDE 5. Slide sleeve over drill bit and snap into drill adapter DRIVE 6. Insert anchor into the end of the sleeve, position fixture to be fastened and drive the Tapcon Buildex Condrive Tools are designed to specifically install Tapcon Anchors and to fit standard hammer drills. 1. Select proper fastener diameter / head style / length a) Use selection chart to choose proper length. 2. Drill Hole use selection chart to determine drill bit length and depth of hole a) Choose appropriate drill bit based upon diameter of Tapcon Anchor. b) Drill hole minimum ¼" deeper than Tapcon Anchor to be embedded. Minimum anchor embedment: 1" Maximum anchor embedment: 1-3/4" 3. Drive Anchor WARNING: WARNING: HEAD STYLES Failure to wear safety glasses with side shields can result in serious personal injury. Always wear ANSI compliant eye protection (ANSI Z ). Using the wrong size drill bit will affect performance values and may cause failure. 3/16" diameter has a 1/4" slotted hex washer head (HWH) 1/4" diameter has a 5/16" slotted hex washer head (HWH) 3/16" diameter uses a #2 phillips flat head (PFH) 1/4" diameter uses a #3 phillips flat head (PFH) B 29

30 Tapcon Concrete and Masonry Anchors SELECTION CHART Tapcon Anchors 3/16" Diameter PART 1/4" HWH PART #2 PFH DESCRIPTION FIXTURE THICKNESS STRAIGHT SHANK DRILL BIT PART DRILL BIT DESCRIPTION BOX QTY CASE QTY BULK QTY 3010 BK 3110 BK 3/16" x 1-1/4" 0-1/4" /32" x 3-1/2" , BK 3120 BK 3/16" x 1-3/4" 0-3/4" /32" x 3-1/2" , BK 3130 BK 3/16" x 2-1/4" 1/2" - 1-1/4" /32" x 4-1/2" , BK 3140 BK 3/16" x 2-3/4" 1" - 1-3/4" /32" x 4-1/2" , BK 3160 BK 3/16" x 3-1/4" 1-1/2" - 2-1/4" /32" x 5-1/2" , /16" x 4" 2-1/4" - 3" /32" x 5-1/2" Tapcon Anchors must be installed using all Buildex system components (Tapcon Anchors, Condrive Tools and Tapcon Drill Bits) in order to qualify for ITW Buildex system support. BK Available in Bulk Pack Qty Tapcon Anchors 1/4" Diameter PART 5/16" HWH PART #3 PFH DESCRIPTION FIXTURE THICKNESS STRAIGHT SHANK DRILL BIT PART DRILL BIT DESCRIPTION 3210 BK 3310 BK 1/4" x 1-1/4" 0-1/4" /16" x 3-1/2" , BK 3320 BK 1/4" x 1-3/4" 0-3/4" /16" x 3-1/2" , BK 3330 BK 1/4" x 2-1/4" 1/2" - 1-1/4" /16" x 4-1/2" , BK 3340 BK 1/4" x 2-3/4" 1" - 1-3/4" /16" x 4-1/2" , BK 3350 BK 1/4" x 3-1/4" 1-1/2" - 2-1/4" /16" x 5-1/2" BK 3370 BK 1/4" x 4" 2-1/4" - 3" /16" x 5-1/2" BK 3380 BK 1/4" x 5" 3-1/4" - 4" /16" x 6-1/2" BK /4" x 6" 4-1/4" - 5" /16" x 7-1/2" Tapcon Anchors must be installed using all Buildex system components (Tapcon Anchors, Condrive Tools and Tapcon Drill Bits) in order to qualify for ITW Buildex system support. BK Available in Bulk Pack Qty BOX QTY CASE QTY BULK QTY Accessories PART DESCRIPTION BOX QTY 7001 Condrive Pro Installation Kit 4 BX /32 x 4-1/2 Tapcon Drill Bit 10 BX /16 x 4-1/2 Tapcon Drill Bit 10 BX /32 x 3-1/2 Tapcon Drill Bit 10 BX /16 x 3-1/2 Tapcon Drill Bit 10 BX /16 x 5-1/2 Tapcon Drill Bit 10 BX /32 x 5-1/2 Tapcon Drill Bit C 3/16 x 7 SDS Plus Tapcon Drill Bit C 5/32 x 7 SDS Plus Tapcon Drill Bit 10 CONDRIVE PRO ADVANTAGES Works with all Impact Drivers, Rotary Hammers, Hammer Drills, Tapcon SDS and Carbide Straight Shank Bits. Fast and Easy: only one tool needed to drill and drive Recessed Hex Driver reduces overtorquing, head snapping, and spinouts Fits fully assembled in carrying pouch for easy storage Tapcon SDS Plus Drill Bits are specially designed to be compatible with Condrive Pro Installation Kit. Use the Tapcon bits and Condrive Pro together to install Tapcon anchors for optimal performance. B 30

31 Tapcon Concrete and Masonry Anchors PERFORMANCE TABLES Tension Values (In Normal-Weight Concrete Lbs.) ANCHOR DIAMETER EMBEDMENT DEPTH CONCRETE STRENGTH 2000 PSI 4000 PSI 5000 PSI 1" /16 1-1/2" /4" " /4 1-1/2" /4" Tension and Shear Values (In CMU 1" Embedment) ANCHOR DIAMETER TENSION (Lbs.) SHEAR (Lbs.) LIGHT WEIGHT MEDIUM WEIGHT LIGHT WEIGHT MEDIUM WEIGHT 3/ / For minimum edge distance and spacing distance, please refer to the ICC-ES report or Miami-Dade report for this product. Lightweight and medium-weight Concrete Masonry Units (CMU) were defined by ASTM C 90. Shear Values (In Normal-Weight Concrete Lbs.) ANCHOR DIAMETER EMBEDMENT DEPTH CONCRETE STRENGTH 2000 PSI 4000 PSI 5000 PSI 1" /16 1-1/2" /4" " /4 1-1/2" /4" NOTE: Indicated tension and shear failure values were obtained in tests conducted at CEL Consulting. Designated holding power depends on the quality of the masonry material, depth of embedment and proper hole size. These figures are offered only as a guide and are not guaranteed in any way by Illinois Tool Works Inc. The figures indicate average ultimate tension and shear failure values. A safety factor of 4:1 or 25% of ultimate value is generally accepted as a safe working load. However, reference should always be made to applicable codes for the specific safe working ratio. All values are based on close tolerance holes drilled with Buildex Tapcon carbide drill bits. Performance of the Tapcon anchor may vary in extremely hard concrete aggregates. Consult your Buildex representative for further information. As in the case with all applications, Buildex can only suggest typical fasteners for typical applications and that the connection design is the sole responsibility of the Building Design Engineer, Architect or otherwise responsible person charged with the design of the connection. For further product information, please contact the nearest Authorized Buildex Distributor or the Buildex Technical Service Department at B 31

32 TAPCON Ceiling Anchor DESCRIPTION Tapcon Ceiling Anchors This innovative anchoring system allows the installer to conduct the installation from the ground for ceiling heights 18 foot or lower. The patented pole system allows the installer to drill the hole from the ground through hard to reach areas where pipes and duck work get in the way. The driving mechanism will also tie the wire after the anchor is fully set. ADVANTAGES Install the anchor from the ground. Eliminating the need for scaffolds or expensive scissor lifts and increase your output. No need to set the anchor using a claw hammer. Just drive the anchor in using the installation tool and your are done. Anchors can easily be inspected for correct installation. No need to pay more for a 1/4" drill bit. This anchor requires a 3/16" carbide bit so you can drill faster with less effort. Reversible and removable...can be installed close to an edge. Tie-Wire Head accommodates up to 3/16" wire. SUGGESTED SPECIFICATIONS The fastener used to suspend T-Bar, Gypsum Wall Board Ceilings, or Light Fixtures in Concrete shall be Buildex Tapcon Ceiling Anchor 1/4" x 1-1/4" with Blue Climaseal Coating (TCA-114). TCA allows for easy access through pipes and obstacles. T-Bar ceiling, gypsum wall board ceiling, and safety chains for light fixtures. SELECTION CHART Tapcon Ceiling Anchors PART DESCRIPTION BOX QTY TCA-114 T1-1/4" Tapcon Ceiling Anchor 1000 SP4 TCA Pole for installing 1 TCA-I TCA-I Driver for pole tool 1 B 32

33 Tapcon Ceiling Anchors PERFORMANCE TABLES Ultimate Tension & Shear Values In 4000 PSI Normal-Weight Concrete (Lbs.) ANCHOR DIAMETER ANCHOR EMBEDMENT ULTIMATE TENSION (Lbs.) ULTIMATE SHEAR (Lbs.) 1/4" 1-1/4" 1,310 1,370 Allowable Edge and Spacing Distances In Normal-Weight Concrete (Lbs.) PARAMETER FULL CAPACITY (Critical Distance Inches) REDUCED CAPACITY (Minimal Distance Inches) LOAD REDUCTION FACTOR Spacing - Tension Spacing - Shear Edge Distance - Tension 2-1/2 1-1/ Edge Distance - Shear 3 1-1/ INSTALLATION STEPS 1. Drill hole 1-1/2" deep into the concrete using a 3/16" ANSI Carbide Drill Bit. 4. Install the Tapcon Ceiling Anchor using a 18v cordless drill with a clutch feature until the anchor collar is flush with the concrete surface. 2. Insert Tapcon Ceiling Anchor into the TCA driver. 5. Pull on the installation pole tool until the head of the anchor is free from the TCA driver. 3. Feed tie wire rod through the TCA driver and the Tapcon Ceiling Anchor. Align Tapcon Ceiling Anchor to 3/16" hole 6. Turn the pole tool using the cordless drill until the tie wire rod is securely fastened into itself. B 33

34 E-Z Drywall Anchors DESCRIPTION/SUGGESTED SPECIFICAITONS Drywall Anchor Applications E-Z Ancor Self-Drilling Anchor The E-Z Ancor is a one-piece self-drilling anchor designed for optimal holding performance in gypsum wallboard. Available in zinc or high strength engineered plastic (non-conductive). Ideal anchor for 3/8", 1/2" and 5/8" gypsum wallboard. The Original! Fast and Easy Self-Drilling Anchors ADVANTAGES No hole preparation necessary; pre-drills own small precise hole in gypsum wallboard. Replaces plastic plugs and toggles. Deep thread design provides strong engagement in 3/8" 1/2" and 5/8" gypsum wallboard. Installs quickly and easily with a phillips screw-driver or square drive bit. Full range of anchors to cover all wall fastening applications. Available in corrosion resistant, non-conductive white nylon. Can be easily backed-out. Low profile head. Single point designs for clean cutting installation. E-Z Ancors E-Z Mini E-Z E-Z E-Z Mini Twist-N-Lock Ancor Twist-N-Lock Toggle B 34

35 Electrical Fixtures Plaques and Awards Thermostats Closet Organizers HVAC Fixtures Coat Racks Plumbing Fixtures Curtain Rods Bathroom Accessories Signs Shelving and Supports Bulletin Boards Mirrors Control Systems Picture Frames Decorative Wall Hangings Brackets Office Material Holders Smoke Detectors Clocks Kitchen Accessories Doorbells Telecommunications Equipment Chalk Boards Remote Control Boxes E-Z Drywall Anchors INSTALLATION INSTRUCTIONS LIGHT DUTY & MEDIUM DUTY E-Z ANCORS 1. Place #2 Phillips screwdriver into recess of E-Z Zinc, E-Z Lite, E-Z Mini, E-Z Stud Solver, Twist-N-Lock, or E- Z Plastic Plus. 2. Press into drywall while turning the anchor clockwise until it is seated flush with wall. 3. Place fixture in position over installed E-Z Zinc, E-Z Lite, E-Z Mini, E-Z Stud Solver, Twist-N-Lock, or Plastic Plus. Insert screw with screw driver. Tighten fixture in place. SPECIFICATIONS Material Drilling Capacity Zinc die cast, Carbon, Steel, Nylon PERFORMANCE TABLE E-Z Ancors 3/8", 1/2" and 5/8" gypsum wallboard DRYWALL THICKNESS HOLDING WEIGHT (lbs.) Gypsum Board Thickness 3/8" 1/2" 5/8" HEAVY DUTY E-Z TOGGLE 1. Using a #2 Phillips screwdriver, drill the E-Z Toggle Anchor into drywall until the head of the anchor is seated flush. 2. To set the clamp behind the drywall, place the mounting screw into the anchor and push or tap firmly until approximately 1" of screw is protruding (do not rotate). Then remove the screw. 3. Place fixture over E-Z Toggle, insert screw and continue to turn until fastened tightly (for example when attaching a 1/2" thick fixture, it will require approx. 23 full rotations of the screwdriver to fully tighten the fixture). EZ Mini and Mini Twist-N-Lock E-Z Anchor and EZ Stud Solver Twist-N-Lock E-Z Toggle These performance values are averages obtained under laboratory conditions. Note that these values will change depending on age, moisture content and surface treatment of the drywall (gypsum) material. Appropriate safety factors should be applied to these values for design purposes. SELECTION CHART E-Z Ancors PART WITH SCREWS PART WITHOUT SCREWS DESCRIPTION MATERIAL MAXIMUM FIXTURE THICKNESS ACCOMMODATES SHEETS METAL SCREW SIZE BOX QTY CASE QTY BULK QTY 6411L 6400L S Mini Twist-N-Lock Nylon 3/4" # , M 6400M E-Z Mini Zinc 3/4" #6, #7, # B E-Z Ancor Zinc 3/4" #6, #7, # , EZ Stud Solver Zinc 3/4" # P 6400P B E-Z Twist N Lock Nylon 3/4" # , B - E-Z Toggle Zinc 1/2" # B Available in Bulk Pack Qty E-Z Mini E-Z E-Z E-Z Mini Twist-N-Lock Ancor Twist-N-Lock Toggle B 35

36 Rock-On Backer-On Fasteners Cement Board and Fiber Cement Backerboard Fasteners DESCRIPTION/ADVANTAGES Cement Board Applications ROCK-ON Rib design under head countersinks into dense material while preventing stripouts. Two point types for steel and wood applications. Larger head diameter increases board surface contact for greater pullover resistance. Rock-On is recommended for ACQ treated wood. SPECIFICATIONS ROCK-ON Diameter #9 Thread Form Drill Point Head Style Finish 9-15 Hi-Lo #9 Type S Wafer Head with countersinking ribs Climacoat BACKER-ON Gimlet points starts easily - no predrilling. Serrated thread design provides reduced installation torque and superior holding power. Rib design under head countersinks into dense material while preventing stripouts. #2 square drive prevents bit from slipping. BACKER-ON Diameter #10 Thread Form Drill Point Head Style Finish Serrated Gimlet Wafer Head with countersinking ribs Long life epoxy topcoat/zinc plating. INSTALLATION INSTRUCTIONS 1. A standard screwgun with a depth sensitive nosepiece should be used to install cement board fasteners. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of Adjust the screwgun nosepiece to properly seat the fastener. 3. Worn or damaged bit tips should be replaced. 4. The fastener is fully seated when the head is flush with the work surface. 5. Overdrivng may result in torsional failure of the fastener or stripout of the substrate. 6. The fastener must penetrate beyond the metal structure a minimum of 3 pitches of thread. Cement-type boards or any dense sheathings to steel or wood studs. Wire lath to steel or wood studs. Plywood to steel or wood studs. Hardie Fiber Cement Backerboard B 36

37 Rock-On, Backer-On Fasteners SELECTION CHART Hi-Lo Rock-On Fasteners PART REFERENCE DESCRIPTION HEAD STYLE BX x 1-1/4" #2 PW BX x 1-5/8" #2 PW MATERIAL ATTACHMENT RANGE BOX QTY Up to 3/4" Material Thickness to Wood 3/8"-1" Material Thickness to Steel Up to 1-1/8" Material Thickness to Wood 3/8"-1-3/8" Material Thickness to Steel Cement Board to wood or light gauge steel gauge Backer-On Fasteners PART REFERENCE DESCRIPTION HEAD STYLE BX23206 BX23206 #10 x 1-1/4" #2 SW BX23137 BX23137 #10 x 1-1/4" #2 SW MATERIAL ATTACHMENT RANGE BOX QTY Up to 1/2" Backer Board to Wood Up to 1" Backer Board to Steel Up to 1/2" Backer Board to Wood Up to 1" Backer Board to Steel Backer Board to wood and steel PERFORMANCE TABLES Sheet Steel Gauges GAUGE NO Nominal Decimal Equivalent (Inch) Pullout Values FASTENER STEEL GAUGE (Lbs.) Hi-Lo Backer-On Wood Embedment #2 SPF 2 x 4 1/2" 3/4" 1" 1-1/4" Hi-Lo Backer-On The values listed are ultimate averages achieved under laboratory conditions and apply to Buildex manufactured fasteners only. Appropriate safety factors should be applied to these values for design purposes. B 37

38 Gridmate BR DESCRIPTION/ADVANTAGES Fastening Insulation To Concrete Textured head allows for coverage of stucco. Fins provided high holding power. Non cold-conductive. Non Corrosive. Made from strong Polypropylene. Easy to install. Plastic Insulation Fasteners All Polymer Modified (PM) Systems. Modified Stucco Systems. Exapnded lath over EPS, XPS or ISO rigid insulation. Fiberglass fabric over rigid insulation. Wire mesh over rigid insulation. Attaching rigid insulation to masonry or concrete. SELECTION CHART Gridmate BR Anchor PART REFERENCE DESCRIPTION HOLE DIAMETER MAXIMUM GRIP BOX QTY /4" 5/16" 1-1/2" /2" 5/16" 2-1/2" /8" 5/16" 3-1/4" /4" 5/16" 4" 100 Washer diameter is 1-3/8" PERFORMANCE TABLE Gridmate BR BASE MATERIAL EMBEDMENT ULTIMATE PULLOUT 25 MPA Concrete 1-1/8" 113 lbs. Concrete Block 1-1/8" 113 lbs. Brick 1-1/8" 113 lbs. 8 fasteners per 4' x 8' sheet required. B 38

39 Notes B 39

Need a Door and Frame taken off? Check out our Full Service Door and Frame Department.

Need a Door and Frame taken off? Check out our Full Service Door and Frame Department. Collated Screw Systems DURASPIN COLLATED SCREWS Drywall to Wood Coarse Part No. Description Qty. Interior Wood to Wood (*coarse thread w/wax lube) Part No. Description Qty. GCS6125 1-1/4" 1M GCS6162 1-5/8"

More information

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws. Sheet Steel Facts Fastener Guide for Sheet Steel Building Products August, 2003 Fastener Materials Fasteners are manufactured from several materials and coatings. For the purpose of this fact sheet, the

More information

METAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD. Value through the Roof.

METAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD. Value through the Roof. METAL-TO-METAL FASTENERS QUIKDRILL METAL2METAL METAL2METAL HD Value through the Roof. Reliable Self-Drilling Performance. Superior Marco Value. Value drives everything we do. That s why our exclusive Weather-Tite

More information

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION test TECHNICAL NOTE On Cold-Formed Steel Construction $5.00 Cold-Formed Steel Engineers Institute Washington, DC www.cfsei.org 866-465-4732 SCREW FASTENER SELECTION FOR COLD-FORMED STEEL FRAME CONSTRUCTION

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

ROSKO FASTENERS & SUPPLY, INC FASTENERS FOR CONSTRUCTION

ROSKO FASTENERS & SUPPLY, INC FASTENERS FOR CONSTRUCTION 406 Bell Court Woodstock, GA 30188 www.roskofasteners.com A Customer-Conscious Company OUR MISSION At Rosko Fasteners & Supply we are committed to the profitability of our customers. We consider our customers

More information

FASTENERS QUIKDRILL QUIKGRIP CLIPSCREWS. Value through the Roof.

FASTENERS QUIKDRILL QUIKGRIP CLIPSCREWS. Value through the Roof. FASTENERS QUIKDRILL QUIKGRIP CLIPSCREWS Value through the Roof. METAL-TO-METAL FASTENERS for CANADA QUIKDRILL METAL2METAL Value through the Roof. Reliable Self-Drilling Performance. Superior Marco Value.

More information

METAL-TO-WOOD FASTENERS QUIKGRIP METAL2WOOD METAL2WOOD HD METAL2WOOD XD LOPRO 300SS. Value through the Roof.

METAL-TO-WOOD FASTENERS QUIKGRIP METAL2WOOD METAL2WOOD HD METAL2WOOD XD LOPRO 300SS. Value through the Roof. METAL-TO-WOOD FASTENERS QUIKGRIP METAL2WOOD METAL2WOOD HD METAL2WOOD XD LOPRO 300SS Value through the Roof. Proven Performance. Huge Selection. Marco Quality. Value drives everything we do. That s why

More information

YUKON PATIO COVER INSTALLATION INSTRUCTIONS

YUKON PATIO COVER INSTALLATION INSTRUCTIONS YUKON PATIO COVER INSTALLATION INSTRUCTIONS Before You Begin: Consult your local building department for any required permits You may be required to obtain a building permit for this structure. Contact

More information

ANCHORS SLEEVE ANCHORS BOLT DIAMETER

ANCHORS SLEEVE ANCHORS BOLT DIAMETER SLEEVE ANCHORS No hole spotting. No mis-alignments. Simply drill through the fixture into concrete, insert and tighten. Preassembled for fast, easy installation. No special tools necessary; meets federal

More information

Coatings ASTM B117 SST Salt Spray Test Kesternick Phosphate Zinc E-Coat Dip Spin Coatings

Coatings ASTM B117 SST Salt Spray Test Kesternick Phosphate Zinc E-Coat Dip Spin Coatings Head and Thread types Coatings ASTM B117 Two major types of coating tests: SST Salt Spray Test screws are placed in a container and a salt solution is sprayed on the screws for a number of hours, checking

More information

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW A21-1 1160 CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD S For light duty applications in solid materials Color coded diameters for easy identifi cation Acid resistant NYLON FLANGED:

More information

Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum

Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum u Uses THE PERLOK CR 1.2 BASE SHEET FASTENER is a one piece unit, precision formed from G-90 galvanized

More information

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED INSTALLATION INSTRUCTIONS LS-24 24 X 12-2 X 7 1/2 FRAME ACTUAL FRAME BASE SIZE: 24 X 12-2 LOAFING SHED Our unique assembly process quickly transforms the individual pieces into a finished structure that

More information

Large Diameter Tapcon

Large Diameter Tapcon CONCRETE ANCHORING SPECIALISTS Large Diameter Tapcon (LDT ) Anchors Finished head, Removable Anchor DESCRIPTION/SUGGESTED SPECIFICATIONS Self-threading Anchors SPECIFIED FOR ANCHORAGE INTO CONCRETE The

More information

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications UltraCon Masonry Fasteners High Performance in a Wide Range of Applications The UltraCon masonry fastening system from Elco Construction Products offers optimal performance in a wide range of masonry applications.

More information

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED INSTALLATION INSTRUCTIONS LS-30 30 X 12-2 X 7 1/2 FRAME ACTUAL FRAME BASE SIZE: 30 X 12-2 LOAFING SHED Our unique assembly process quickly transforms the individual pieces into a finished structure that

More information

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS 1290363 Revision 1 12/16 Page 1 Weather Shield Mfg., Inc. NOTICE CAUTION! Failure to install and maintain our product according to these instructions

More information

Screw selecting guide for Norex & Noroc panels installation (metal screw)

Screw selecting guide for Norex & Noroc panels installation (metal screw) Screw selecting guide for Norex & Noroc panels installation (metal screw) Anchor Capacity (lbs.) (1)()() Girt thickness (2) Panel type NOREX Mfg. 2 x TEKS ( 1) 2 x TEKS ( 28) 2 x IMPAX SD ( 1) 2 x IMPAX

More information

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED INSTALLATION INSTRUCTIONS LS-12 12 X 12-2 X 7 1/2 FRAME ACTUAL FRAME BASE SIZE: 12 X 12-2 LOAFING SHED Our unique assembly process quickly transforms the individual pieces into a finished structure that

More information

Multi-Set II Drop-In Anchors

Multi-Set II Drop-In Anchors CONCRETE ANCHORING SPECIALISTS Internally Threaded Heavy- Duty Anchoring Systems DESCRIPTION/SUGGESTED SPECIFICATIONS Drop-In, Shell-Type Anchors SPECIFIED FOR ANCHORAGE INTO CONCRETE Drop-In, shell-type

More information

T3ss Gas Powered Tool

T3ss Gas Powered Tool T3ss Gas Powered Tool Gas Technology Single Pin Gas Tool Fuel Injection Cross Over Technology /SUGGESTED SPECIFICATIONS Crossing Over from Powder to Gas THE PREMIER FASTENING SYSTEM FOR THE ELECTRICAL

More information

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications UltraCon Masonry Fasteners High Performance in a Wide Range of Applications The UltraCon masonry fastening system from Elco Construction Products offers optimal performance in a wide range of masonry applications.

More information

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit.

Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installation Guidelines For Quaker Window Products Aluminum flange fin sub sill & receptor system using a T mulled twin window unit. Installer: Read these instructions completely before starting any installation.

More information

Metal Roof Installation Manual. Chapter 14: Fasteners

Metal Roof Installation Manual. Chapter 14: Fasteners Metal Roof Installation Manual Chapter 14: Fasteners Chapter 14: Fasteners Chapter Contents 14. Introduction... 14-1 14.1 Fastener Parts and Installation... 14-1 14.1.1 Points... 14-1 14.1.2 Heads... 14-1

More information

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN

INSTALLATION SHOP DRAWINGS FOR MINNEAPOLIS, MN MINNEAPOLIS, MN 2-0- 2-- General Notes Abbreviations Deviations from Architectural Specifications Deviations from Architectural Drawings ALUM. = ALUMINUM B.O. = BY OTHERS CONT. = CONTINUOUS. = CLEARANCE

More information

DEKFAST COMMERCIAL ROOFING FASTENERS

DEKFAST COMMERCIAL ROOFING FASTENERS STEEL DECKING & UL DECKING ATTACHMENT FASTENERS Used for attachment of steel decking attachment to 12ga up to 1/2 thick steel purlin structures. #10 x 3/4 designed for steel B deck side lap stitch. The

More information

Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum

Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum Perlok CR 1.2 Base Sheet Fastener Secure Base Sheets to Lightweight Insulating Concrete or Gypsum u THE PERLOK CR 1.2 BASE SHEET FASTENER is a one piece unit, precision formed from G-90 galvanized steel,

More information

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 04080 MASONRY ANCHORAGE AND REINFORCEMENT Display hidden notes to specifier. (Don't know how? Click Here) A. Post installed masonry anchors. B. Miscellaneous

More information

Submittal Sheet. Product: Item# Description Unit Pack

Submittal Sheet. Product: Item# Description Unit Pack Submittal Sheet Submittal Sheet #0309412 Bugle Head Screws (212) Product: Item# Description Unit Pack C368 6 x 1-1/4-in, Bugle Head, Fine Thread,, Phosphate, Collated 1,000 1268YZ 10 x 3-1/2-in, Bugle

More information

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary.

INSTALLATION INSTRUCTIONS for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) ImpOrTaNT INFOrmaTION & GlOssary. for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025) Thank you for selecting JELD -WEN products. Attached are JELD-WEN s recommended installation instructions for metal clad wood windows

More information

REGAL. Installation Manual

REGAL. Installation Manual REGAL Installation Manual General Information The details shown on the following pages are suggestions or guidelines for installing the Regal system. The installation details shown here are proven methods

More information

Wedge Type Anchors. Trubolt. Wedge Anchor ADVANTAGES

Wedge Type Anchors. Trubolt. Wedge Anchor ADVANTAGES CONCRETE ANCHORING SPECIALISTS Dependable, Heavy-Duty, Inspectable, Wedge Type Expansion Anch 2015 IBC Compliant DESCRIPTION/SUGGESTED SPECIFICATIONS Wedge Type Anchs SPECIFIED FOR ANCHORAGE INTO CONCRETE

More information

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications

UltraCon Masonry Fasteners High Performance in a Wide Range of Applications UltraCon Masonry Fasteners High Performance in a Wide Range of Applications The UltraCon masonry fastening system from Elco Construction Products offers optimal performance in a wide range of masonry applications.

More information

COMPOSITE SIDING INSTALLATION GUIDE

COMPOSITE SIDING INSTALLATION GUIDE CENTURY HOME LIVING COMPOSITE SIDING INSTALLATION GUIDE Read all instructions prior to installing any siding product. Failure to install and finish this product in accordance with all local building codes,

More information

Adorn Mortarless Stone Veneer Installation Natural Concrete Products

Adorn Mortarless Stone Veneer Installation Natural Concrete Products Adorn Mortarless Stone Veneer Installation Adorn Mortarless Stone Veneer can be used on new or existing construction. Adorn is nailed or screwed onto the wall; therefore no brick ledge is required. Adorn

More information

Approvals and Listings 3. Sammys for Wood 4. Sidewinder for Wood 5. Sammys Swivel Head for Wood 5. Sammys for Steel 6. Sidewinder for Steel 7

Approvals and Listings 3. Sammys for Wood 4. Sidewinder for Wood 5. Sammys Swivel Head for Wood 5. Sammys for Steel 6. Sidewinder for Steel 7 PRODUCT CATALOG 2 TABLE OF CONTENTS TABLE OF CONTENTS Approvals and Listings 3 Sammys for Wood 4 Sidewinder for Wood 5 Sammys Swivel Head for Wood 5 Sammys for Steel 6 Sidewinder for Steel 7 Sammys Swivel

More information

Stainless Steel Anchors. for Concrete & Masonry

Stainless Steel Anchors. for Concrete & Masonry Innovative Fastening Technologies Stainless Steel s for Concrete & Masonry The Industry Leader in Critical Fastening Stainless Steel s for Concrete and Masonry Applications To meet the needs of the wide

More information

GCN150 Gas-Actuated Concrete Nailer

GCN150 Gas-Actuated Concrete Nailer GCN0 Gas-Actuated Concrete Nailer The GCN0 gas-actuated concrete nailer is a portable fastening tool for attaching light-duty fixtures such as drywall track, furring strips, hat track and angle track to

More information

Installation Guidelines

Installation Guidelines Page 1 Tools You ll Need 4 ft. Carpenter s level Chalk line (to mark U channel locations) Cordless drill/nut driver Caulking gun Chop saw with a metal cutting blade on it (required to make accurate and

More information

SECTION SHEET METAL FLASHING AND TRIM

SECTION SHEET METAL FLASHING AND TRIM SECTION 07620 PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Formed roof drainage sheet metal fabrications. 2. Formed low-slope roof sheet metal fabrications. 1.2 SUBMITTALS A. Shop Drawings: Show

More information

Letter of Transmittal/Submittal

Letter of Transmittal/Submittal Letter of Transmittal/Submittal FROM: TO: Baker Concrete Construction 1904 Jasper Street DATE JOB NUMBER 09/23/10 Aurora, CO 80011 9921 303.367.8111 ATTENTION Nick Dewald 937.536.9000 RE: Bruce Herman

More information

DW HORIZONTAL INSTALLATION

DW HORIZONTAL INSTALLATION AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S

More information

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

SERIES 4070-T GENERAL ASSEMBLY AND INSTALLATION INSTRUCTIONS Table of Contents I. Care and Maintenance... 2 II. Tools / Materials, Sealant Requirements, & Anchor Instructions... 2 III. Structure Verification & Sub-Sillpan Installation... 3 1. Opening Verification...3

More information

GLOSSARY OF TERMS SECTION 8

GLOSSARY OF TERMS SECTION 8 GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the

More information

SecuAnch Roof Anchor System

SecuAnch Roof Anchor System Height Safety Products Email: marketing@fallprotec.com SecuAnch Roof Anchor System 1 Presentation The SecuAnch lifeline is designed to be permanently installed on buildings and other structures where maintenance

More information

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR www.quakerwindows.comv www.quakercommercialwindows.com PO Box 128 504 Highway 63 South Freeburg, MO 65035 800-347-0438 573-469-4151 (fax) Installation Guidelines For ALUMINUM M-SERIES 3 PANEL SLIDING DOOR

More information

How To Install Windows: Nail-Fin Application

How To Install Windows: Nail-Fin Application How To Install Windows: Nail-Fin Application Required Tools & Materials: Materials: 1 3/4" galvanized roofing nails. Nails must penetrate at least 1" into framing For mulled and/or DP50 or above units:

More information

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL The ProTEC panels are manufactured with grooves on all four sides to accept the steel components. This grooving applies to the regular panel whose

More information

ALUMA-VENT AWNING REGULAR END STYLE INSTALLATION INSTRUCTIONS

ALUMA-VENT AWNING REGULAR END STYLE INSTALLATION INSTRUCTIONS ALUMA-VENT AWNING REGULAR END STYLE INSTALLATION INSTRUCTIONS Contact us at: 1-888-442-2928 or www.americana.com Options in your kit: A. Splice Pg 16 B. Column Pg 17 C. C-Channel Brace Pg 19 D. Runner

More information

SteelChief Installation Instructions for pre-assembled panel form sheds GABLE ROOF

SteelChief Installation Instructions for pre-assembled panel form sheds GABLE ROOF SteelChief Installation Instructions for pre-assembled panel form sheds GABLE ROOF Please read fully before commencing work...any queries will be promptly answered, contact theboss@steelchief.com.aui MPORTANT

More information

Shapes Siding. Perfection Shingles. Chalk Line

Shapes Siding. Perfection Shingles. Chalk Line Snap a Chalk Line Shapes Siding Perfection Shingles Chalk Line To establish a straight reference line to guide the positioning of the starter strip and the first course of siding, snap a chalk line. starter

More information

Dimensions Mechanical and Performance Requirements. Drop-In Anchors Hollow Wall, Steel Regular Style Drive Style...

Dimensions Mechanical and Performance Requirements. Drop-In Anchors Hollow Wall, Steel Regular Style Drive Style... Dimensions Mechanical and Performance Requirements Drop-In Anchors... 257 Hollow Wall, Regular Style... 258 Drive Style... 259 Hollow Wall, Plastic Ribbed... 260 Conical, Light Duty... 261 Fluted, Light

More information

Rolling Curtain door Manual

Rolling Curtain door Manual Rolling Curtain door Manual Installation Maintenance parts Model 944 PHONE 800 448 8979 FAX 800 236 8722 website www.tracrite.com EMAIL tr@tracrite.com ADDRESS 216 Wilburn Road Sun Prairie, WI 53590 This

More information

Installation Instructions

Installation Instructions For Medium (15-18.5K) + Heavy duty (-8.5K) Air Conditioner READ BEFORE INSTALLING UNIT To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges

More information

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes General Guidelines These instructions show one type of installation and are intended for the professional

More information

installation guide Villa

installation guide Villa installation guide Villa Table of Contents Introduction............................. 2 Safety................................... 2 Tools.................................... 2 Codes & Requirements....................

More information

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032)

INSTALLATION INSTRUCTIONS for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII032) for Wood Bay or Bow Windows with Nailing Fin or Exterior Trim (JII0) Thank you for selecting JELD-WEN products. Attached are JELD-WEN s recommended installation instructions for wood and clad wood bay

More information

UL Construction No. 254

UL Construction No. 254 UL Construction No. Wind-Uplift - Class 90 (See Item No. ) / Fire Not Investigated Metal Roof Deck Panels* Snap-Clad No. MSG or No. MSG min. thickness coated steel panels. Panels in. wide max., 0 in. wide

More information

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS

ULTRA WINDOW & DOOR EXPANDERS AND RECEIVERS INSTALLATION INSTRUCTIONS ULTRA WINDOW & DOOR S AND RECEIVERS INSTALLATION INSTRUCTIONS! CAUTION: *REMEMBER SAFETY FIRST* Proper Eye and! Hearing Protection must always be worn during installation of all window and door products.

More information

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM SIX INCH ALPHA MODULE INSTALLATION KEWAUNEE SCIENTIFIC CORPORATION SIX INCH ALPHA MODULE ANCHORING SYSTEM After Alpha module has been set in desired location. Adjust the four adjustment bolts until the

More information

Tools required by installer: Materials required by installer:

Tools required by installer: Materials required by installer: Installation Guidelines For Quaker Window Products Vinyl product line (Single Hung, Double Hung, Sliding Window, Fixed Window, Casement, Awning, and Hopper) Installer: Read these instructions completely

More information

Peco Fasteners 3/8 Internal Plug Drop In 50 Per Jar 3/8-16 SMART DROP IN ANCHOR ZINC

Peco Fasteners 3/8 Internal Plug Drop In 50 Per Jar 3/8-16 SMART DROP IN ANCHOR ZINC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category 6337J 3/8-6 Smart Drop In Zinc Peco Fasteners,

More information

Installation Guidelines

Installation Guidelines Page 1 Tools You ll Need 4 ft. Carpenter s level Chalk line (to mark U channel locations) Cordless drill/nut driver Caulking gun Chop saw with a metal cutting blade on it (required to make accurate and

More information

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16

Equilibrium. Conference Table. Installation Instruction. Revision B 11/07/16 Equilibrium Conference Table Installation Instruction Revision B 11/07/16 Equilibrium End User Agreement Enwork Equilibrium table bases must be installed directly onto a four inch minimum thickness concrete

More information

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING

TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING TECHNICAL GUIDE BEONSTONE PANELIZED STONE SIDING TABLE OF CONTENTS This installation guide provides detailed step-by-step instructions for do-it-yourself projects. We invite you to read it carefully and

More information

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8 1 Table of Contents Page(s) Installation Guide for Profile with Hidden Fasteners 3 Installation Steps 4, 5 Prestige Series Moldings 6, 7 Other Accessories 8 Trims & Accessories 9 Eave Starters 10 Gableboards

More information

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY

HANDRAIL HEIGHT PER LOCAL CODE AUTHORITY WITH OPTIONAL S.S. S PLEASE READ PLEASE READ THESE INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING THE INSTALLATION! THIS INSTRUCTION SHEET IS INTENDED TO PROVIDE A SPECIFIC GUIDE TO FOLLOW FOR THE INSTALLATION

More information

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION CONCRETE ANCHORING. Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 03 15 00 CONCRETE ANCHORING Display hidden notes to specifier. (Don't know how? Click Here) A. General purpose mechanical anchors for horizontal and vertical

More information

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions

14000 I/O Series Flush Glaze. Fabrication and Installation Instructions 14000 I/O Series Flush Glaze Fabrication and Installation Instructions Last saved on 12/18/2009 Table of Contents GENERAL CONSTRUCTION NOTES...3 EXTRUDED ALUMINUM PARTS...4 ACCESSORIES...5 OVERVIEW...6

More information

GLOBALLOY HIGH STRENGTH MASONRY ANCHORS KEEP MACHINERY AND FIXTURES SECURELY IN PLACE

GLOBALLOY HIGH STRENGTH MASONRY ANCHORS KEEP MACHINERY AND FIXTURES SECURELY IN PLACE GLOBALLOY HIGH STRENGTH MASONRY ANCHORS KEEP MACHINERY AND FIXTURES SECURELY IN PLACE THE HEAVIER THE LOAD THE HARDER THEY HOLD PRE-ASSEMBLED READY TO USE NO EXTRA NUTS OR BOLTS NO RE-SPOTTING OF MACHINERY

More information

Installation Instructions

Installation Instructions For Medium (15-18.5K) + Heavy duty (22-28.5K) Air Conditioner READ BEFORE INSTALLING UNIT To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp

More information

UNIVERSAL INSTALLATION INSTRUCTIONS FOR CARPORTS

UNIVERSAL INSTALLATION INSTRUCTIONS FOR CARPORTS UNIVERSAL INSTALLATION INSTRUCTIONS FOR CARPORTS FRAME SIZES: WIDTH: 10, 12, 14, 16, 18, 20, 24, AND 30 ON CENTER FRAME SPACING: 4, 4 1/2, AND 5 FRAME LENGTH: 4 ON CENTER 20-2, 4 1/2 ON CENTER 18 AND 5

More information

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window

Installation Guidelines. Next Dimension. Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window Installation Guidelines Next Dimension Single Hung / Single Hung Fixed / Double Hung / Sliding Window / Fixed Window Windsor Windows & Doors Windsor Windows & Doors 900 S. 19 th St. 2210 Stafford St. Extn

More information

Elco Construction Products 1301 Kerr Drive Decorah, IA fax:

Elco Construction Products 1301 Kerr Drive Decorah, IA fax: Technical Manual 2010 HangerMate anchors were designed to speed installation of fire sprinkler, HVAC, refrigeration, general piping, and electrical systems. They can also be used to install strut channels,

More information

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter PRODUCT INFORMATION Internally Threaded Expansion Anchor PRODUCT DESCRIPTION The is an all-steel, machine bolt anchor available in carbon steel. It can be used in solid concrete, hard stone, and solid

More information

POCKETING MULTI-SLIDE DOOR SYSTEM

POCKETING MULTI-SLIDE DOOR SYSTEM PMSD POCKETING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS READ THESE INSTRUCTIONS COMPLETELY BEFORE STARTING ANY INSTALLATION! CAUTION Lead-based paint may be present in older homes, and the removal

More information

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP

NX8 SERIES 6-1/4 HANDRAIL W/ VINYL HANDGRIP 6-1/4 HANDRAIL W/ VINYL HANDGRIP TYPICAL ASSEMBLY 5 2 BUTT JOINT 12 10 9 1 8 11 6 3 7 4 BUTT JOINT COMPONENT LIST 1 LEFT RETURN 7 UPPER IMPACT ABSORBER 2 RIGHT RETURN 8 LOWER IMPACT ABSORBER 3 OUTSIDE

More information

Storing, Handling, and Cutting Steel Panels

Storing, Handling, and Cutting Steel Panels Storing, Handling, and Cutting Steel s Storing Specifically check your quantities, colors, and lengths All materials should be used as soon as possible Steel bundles should be stored indoors with enough

More information

SunTrackerTwo Preparation

SunTrackerTwo Preparation TOLL FREE:(888)29-2705 FAX:(941)77-9460 info@eco-smart.com SunTrackerTwo Preparation Cutting Holes and Preparing Curbs T.G.I Or Truss CIRALIGHT INSTALLATION MANUAL Page 1 Cutting Holes and Preparing Curbs

More information

PV MOUNTING SYSTEM INSTALLATION MANUAL

PV MOUNTING SYSTEM INSTALLATION MANUAL PV MOUNTING SYSTEM INSTALLATION MANUAL The ROOF TRAC PV mounting system makes the installation of PV modules for rooftop installations easy, safe and attractive. The patented (pat #6,360,491) PV support

More information

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

RELINER INSIDE DROP SYSTEM SPECIFICATIONS 1. PRODUCT NAME RELINER INSIDE DROP SYSTEM U.S. Patent 6074130 Canadian Patent # 2269565 All RELINER Products are proudly made in the U.S.A. 2. MANUFACTURER RELINER /Duran Inc. 53 Mount Archer Rd. Lyme

More information

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42 - 60 Plasma Screens Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens Models: PLAV 70-UNL, PLAV 70-UNL-S PLAV 70-UNLP, PLAV 70-UNLP-S R This product is UL Listed. It must be

More information

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners?

FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S. Which FERO Tie Systems Require Fasteners? FASTENERS C O M P AT I B L E W I T H F E R O T I E S Y S T E M S Which FERO Tie Systems Require Fasteners? Structural Actions: Fastener,, or Both? With the exception of FERO tie systems that are directly

More information

Storefront Installation Guide

Storefront Installation Guide Storefront General Notes: 1. Check Contract Documents and Shop Drawings. Understand and clarify any Field Verify Notes and approvals of drawings and products to be familiar with the project. Installation

More information

Cable Cutter Square. 25 Tape Measure. Chalk Line Level Loctite 242 Blue

Cable Cutter Square. 25 Tape Measure. Chalk Line Level Loctite 242 Blue ATLANTIS RAIL Contact Information: Atlantis Rail Systems 70 Armstrong Road 3900 Civic Center Drive Plymouth, MA 02360 North Las Vegas, NV 89030 (800) 541-6829 or (508) 732-9191 (508) 732-9798 www.atlantisrail.com

More information

Curtain Wall Installation Guide

Curtain Wall Installation Guide Curtain Wall Installation Guide Curtain Wall Installation Guide 1 IMPORTANT NOTICES! Important Notices & Information Manufacturer s Notes: The building envelope must be correctly prepared with weather

More information

INSTALLATION GUIDE. TRANZFORM Sound TRANZFORM Space

INSTALLATION GUIDE. TRANZFORM Sound TRANZFORM Space INSTALLATION GUIDE TRANZFORM Sound TRANZFORM Space Cornell Iron Works, Inc. 100 Elmwood Ave. Crestwood Industrial Park Mountain Top, PA 18707 Phone: 800.233.8366 or 570.474.6773 Fax: 800.526.0841 INSTALLATION

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS A CSW Industrials Company FR and FRE Roof Expansion Joint Covers IMPORTANT The following instructions are very important. Read them carefully, and be sure you understand them

More information

Fasteners Engineered for Cutting Edge Performance

Fasteners Engineered for Cutting Edge Performance ?I Fasteners Engineered for Cutting Edge Performance 6357 Reynolds Road, Tyler, Texas 75708 P.O. Box 4515, Tyler, Texas 75712 800-352-4864 800-352-3940 Fax 903-592-2826 903-592-1583 Fax 9950 Princeton

More information

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools...

INS A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Verify Curb Installation Required Installation Tools... INS-88.300-0A KSR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE 1. Verify Curb Installation... 2 2. Required Installation Tools... 2 3. Unpacking the KSR... 3 4. Attach KSR Bottom Rail to Curb... 5 5. Attach

More information

KS SERIES - VERTICAL INSTALLATION

KS SERIES - VERTICAL INSTALLATION CS-DS-01-KSV CS DISCLAIMER CS-PJ-01-KSV KS42SL EXPANDED PANEL JOINT CS-PJ-02-KSV KS42SL ENGAGED PANEL JOINT CS-PJ-03-KSV KS45SL EXPANDED PANEL JOINT CS-PJ-04-KSV KS45 FLAT ENGAGED PANEL JOINT CS-PJ-05-KSV

More information

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

GE Monogram. Installation. Instructions. 36 Vent Hood. Model ZV750. Call anywhere in the US and Canada - at :: rangehoods. com GE Monogram Instructions Model ZV750 GE Monogram at:: rangehoods. com is a division of CAUTION WARNING Before you begin Read these instructions completely and carefully. IMPORTANT:

More information

NX7 SERIES 5-1/2 HANDRAIL

NX7 SERIES 5-1/2 HANDRAIL STORAGE & HANDLING The handrails are shipped unassembled. Upon receipt, immediately check all material for any damage that may have occurred in transit and verify that all of the items and quantities are

More information

CFDTT-01. Control Joint Study (General)

CFDTT-01. Control Joint Study (General) Trim Method Classic Method Notes: Control joints are required and should be located by the designer at the following locations on the construction documents: 144 sf (13.4 sm) is the maximum overall area

More information

Hang-TITE Rod Hanger Screws

Hang-TITE Rod Hanger Screws Description The Hang-TITE Rod Hanger Screw is a one-piece, internally threaded anchor designed for suspending threaded rod for applications like cable-tray, pipe hanging, fire protection, and electrical

More information

Flashing Materials. Rough Opening Preparation

Flashing Materials. Rough Opening Preparation Installation Instructions for CertainTeed New Construction Windows Handling vinyl windows CAUTION: Always store vinyl windows and doors in an upright position on a slight angle. Never lay them flat or

More information

Rayport G Eco Dealer Kit

Rayport G Eco Dealer Kit Rayport G Eco Dealer Kit Installation Guide www.aetenergy.com Supporting a Cleaner, Greener Tomorrow 1. Table of Contents 1. Table of Contents P2 2. Installer Notes P3 3. Parts List P4-7 4. Tool List P8

More information

For. Metal Roofing. Cement Roofing. Metal Framing & Fixing. Concrete Fixing

For.   Metal Roofing. Cement Roofing. Metal Framing & Fixing. Concrete Fixing Metal To Metal Fixing Calcium Silicate Boards Metal To wood Fasteners For Concrete Metal Roofing & Cladding For Metal Roofing Fixing AHU & Ventilators Doors & Window Framing Cement Roofing Metal Framing

More information

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11 INSTALLATION MANUAL CONTENTS Important Notes... 2-4 Weather Protective Barriers... 2 Storage and Transportation... 2 Tools and Equipment... 2 Fastener Choices... 3 Wall Preparation... 3,4 Flashing... 4

More information