System of INVISIO Vertical Façades

Size: px
Start display at page:

Download "System of INVISIO Vertical Façades"

Transcription

1 System of INVISIO Vertical Façades Technical document No. 21 / Version 3 / July 2006

2 CONTENT 1.0 Technical Description of a Vertical Façade System With Secret Fixing - INVISIO [1] 1.1 General [1] 1.2 Panel profile [2] 1.3 Panel composition [2] 1.4 Technical data [2] Basic technical data [2] Coatings [3] 2.0 Design Procedure [4] 2.1 Panel tickness selection [4] 2.2 Structural design data [4] 2.3 Fixing methods [4] Intermediate support [5] Bottom end support [5] Panel to panel junction [6] Top end support [6] 2.4. Panel fixing [7] 3.0 Assembly Instructions [8] 3.1 Installation recommendations [8] 3.2 Sealing [9] 3.3 Lifting methods [10] 3.4 Installation details [11] Fixing to an intermediate support [11] Connection to the main beam [12] Connection of a façade to the main beam [12] Drip flashing extension detail [13] Drip flashing cut for water outlet [13] External corner [13] Corners with a pre-fabricated corner panels [15] Extension of a façade [16] Parapet [17] Window installation [17] 4.0 Packing, Transport and Storing [19] 4.1 Packing [19] 4.2 Transport [19] 4.3 Storage [20] 5.0 Maintenance [21] 5.1 Annual checking of a façade [21] 5.2 General recommendations [21] All rights to alteration reserved. The last versions of documents is available on

3 1.0 Technical Description of the Vertical Façade System with Secret Fixing - INVISIO 1.1 General The basic of the INVISIO vertical façade system consists of a Trimoterm FTV INVISIO façade panels standard module width of 1000 mm with method secret fixing (Fig. 1 and 2). Trimoterm FTV INVISIO panels are fixed through a side lap joint to steel cladding rails or concrete structure with integrated steel profile by means of a special supporting element (Fig. 5). The supporting element is intended for the load distribution over a large overlying surface. It is made of stainless steel in a thickness of 2 mm and is 160 mm long. The longitudinal edge of the neighbouring panel covers these elements and panel fixings so that they are not visible on the façade accomplished. A fixing section is shown in Fig. 4. Distance tube (Fig. 1 and 4) is to be inserted into the panel joint where secret fixing is used. Requirements for other fixing types are stated in Section 2. The INVISIO system of vertical façades has excellent technical properties, a long life span and allows the greatest creative freedom in façade design. The range of applications for INVISIO vertical façades is extremely wide. They are suitable for business, trade, factory buildings as well as buildings constructed for representative purposes. Fig. 1: Elements in a joint Fig. 2: Panel assembly Fig. 3: Detail of fixing to supports made of various materials Fig. 4: Detail of fixing the INVISIO façade Fig. 5: Supporting element 1 Trimoterm FTV INVISIO panel 2 Self-tapping screw _x_ 3 Supportnig element 4 Distance tube 5 Sealing tape (factory applied) 0 WARNING: For side lap panel fixing stainless steel fixing screws WITHOUT washer in combination with an supporting element and distance tube are used! No.21/V-3/

4 1.2 Panel Profile Steel sheet on the external side of a panel can be performed in a standard, micro-lined, smooth profile or multi vario; on the inner side in a standard, smooth or v - profile. With respect to the profiles of steel sheet the following types of Trimoterm FTV INVISIO panels (Fig. 6) are possible. Fig. 6: Possible forms of Trimoterm FTV INVISIO façade panels Side A Side B S - profile V - profile Smooth profile Micro-lined profile Profile Type Side A Side B S - profile V - profile Smooth Micro-lined Multi vario Side A is usually the external side of a panel Multi vario profile 1.3 Panel Composition Trimoterm FTV INVISIO fireproof panels consist of two shallow profiled, coated steel sheet faces in thicknesses of 0.5 mm, 0.6 mm or 0.7 mm. The steel sheet is bonded to the panel core made of non-combustible mineral wool lamellas of class A1 (EN ). All three layers make a solid panel in a thickness of mm. A protective polyethylene foil is applied on the panel surface to protect it during handling, transport and assembly. The foil is removed after the assembly has been completed. Panels can be up to 14 m long. 1.4 Technical Data Basic Technical Data Table 1: Technical data for Trimoterm FTV INVISIO façade panels Technical data FTV INVISIO FTV H 60 FTV H 80 FTV H 100 FTV H 120 FTV H 150 FTV H 200 Panel thickness [mm] Weight FTV H [kg/m 2 ] Fe 0.6 / Fe ,5 U Thermal conductivity [W/m 2 K] * (EN ISO 6946) Fire resistance class (acc to EN , EN ) Combustibility of insulant core (acc to EN ) Rw Sound reduction [db] (EN ISO 140-3) ,20 EI 60 EI 90 EI 120 EI 180 Non - combustible, class A Cover width [mm] 1000 Panel length [m] up to 14 * Values measured on the panels Trimoterm FTV 1000 STANDARD. 2 No.21/V-3/

5 1.4.2 Coatings Two types of steel sheet coatings are used: - Protection based on polyester marked as SP standard protection. - Protection based on polyvinyl idenfluoride marked as PVDF (available on request). Steel sheet is preliminary hot galvanised and colour pre-coated. Thickness of a zinc layer is 275 g (Zn)/m 2 (EN 10326, EN 10327) while colour coating is performed by Coil Coating procedure. This denotes painting between cylinders and drying in the furnace at a temperature of minimum 200 C. All possible shades of the RAL scale are possible. Standard colour shades of Trimoterm INVISIO panels (valid for protection based on polyester - SP) are: - RAL grey while, - RAL aluminium white. Other paint coatings are available upon a special request (e.g. based on PVC, silicone, polyester, Corus HPS200, Corus Prisma etc.) that may have other properties. Table 2: Basic properties of an individual type of protection TYPE OF CORROSION PROTECTION SP SP PVDF PVDF+ PUR PVC(P) PVC+F Corrosion classification [DIN ] II III III III III III III Total organic thickness (my) [EN ] Corrosion resistance category ** Types of outdoor atmosphere / corrosivity category [EN ] Types of indoor atmosphere /corrosivity category [EN ] External EN RC3 RC3 RC4 RC5 RC5 Internal EN CPI2 CPI3 CPI4 CPI5 CPI4 CPI5 Rural - normal C2 *** Urban and industrial C3 and C4 *** Martitme 0 < 10 km from sea C5 - M *** 10 < 20 km from sea C4 *** Severe industrial C5 - I *** Non-corrosive atmosphere Routine upkeep - normal Low humidity Non-corrosive atmosphere Routine upkeep - normal Medium humidity Non-corrosive atmosphere Non-intensive cleaning High humidity Slightly corrosive atmosphere Non-intensive cleaning Humid (risk of condensation) Corrosive atmosphere Intensive cleaning Very humid (frequent risk of condensation) Highly corrosive atmosphere Highly intensive cleaning Satureted (permanent risk of condensation) Ai1-40 Cà25 C 0% - 40%* Ai2 0 Cà25 C 40% - 60%* Ai3 0 Cà25 C 60% - 80%* Ai4 0 Cà30 C 60% - 80%* Ai5 0 Cà35 C 80% - 90%* Ai6 0 Cà40 C 90% - 100%* Temperture resistance ( C) UV resistance category [EN ] Ruv3 Ruv4 Ruv4 Ruv4 Ruv2 Flexibility Staining resistance Note: suitable without reservations very suitable suitable suitable with reservations/contact Trimo - unsuitable * Temperature must not fall below condensation point when cleaning. See table for details: Condensation point temperature is shown at specific ambient temperature and relative humidity. In case of cooling down, working temperature must be 3 C above condensation point. ** Corrosion categories are defined by climatic conditions of external and internal building environment. Standard external climatic conditions: C1, C2, C3, C4, C5-M and C5-1. Example: outside atmosphere C3 --> steel sheet of corrosion category RC3 or RC4 is selected. *** Recommended for use North of 45th parallel latitude and maximum temperature 70 C. No.21/V-3/

6 2.0 Design Procedure 2.1 Panel Thickness Selection With respect to the client s or project requirements or in accordance with the legislation appropriate thickness of Trimoterm FTV INVISIO panel shall be selected. Thickness has a direct influence on the load-bearing capacity of the panel, thermal insulation of the façade and heat stability of the structure. 2.2 Structural Design Data Max. spans allowed are determined in relation to the selected panel thickness, loads and support width. Max. span are stated in the Appendix to the Instructions and should be used only as a guide. Exact span should be calculated for each individual building. Trimo s technical department can prepare a calculation of max. spans alowed. 2.3 Fixing Methods Major factors that influence a fixing method: - Wind loading: - basic wind loading, - height of a façade above the ground, - position on the façade (edge areas in a width of up to 2 m). - Temperature loading: - Colour of a panel (group I, II, III). - Static system of panel lying: - Single-, double-, multiple-span. With respect to the factors stated various loading appears on the façade. The fixing method should be adjusted to accommodate them. Characteristic fixing areas are marked in Fig. 7. Tables for calculation of fixings are stated in the Appendix. Fig. 7: Characteristic fixing areas CENTRAL FAÇADE AREA: A - Intermediate support B - Bottom end support C - Top end support E - Panel to panel junction EDGE FAÇADE AREA: A*- Intermediate support B*- Bottom end support C*- Top end support E* - Panel to panel junction * Usually the edge area of a façade is up to 2 m wide. WARNING: Secret fixing at end supports is not sufficient. Usually fixing through a panel is necessary; according to details it should be covered by flashing. A fixing calculation is necessary to determine a fixing method on individual places. Trimo s technical department can prepare such calculation required. 4 No.21/V-3/

7 2.3.1 Intermediate Support Fig. 8: Intermediate support fixing detail 1 Self-tapping screw x 2 Supporting element 3 Expansion element 4 Self-tapping screw x 5 Distance tube * Fixing method in the edge area is usually up to 2 m wide. The necessity of additional fixing is determined by fixings calculation. Such fixing is usually necessary in the edge area see Structural Design Data for Trimoterm FTV INVISIO Type B Bottom End Support Fig. 9: Bottom end support fixing detail 1 Panel beam-closing element 2 Dripping edge of a panel 3 Sealing tape 30 x 20 4 Anchor bolt 5 Self-tapping screw 6 Self-tapping screw 7 Beam of dripping edge flashing 8 Dripping edge flashing support 9 Blind rivet x 10 Sealing tape EPDM 2 x 30 x Panel beam-closing element top 12 Sealing tape 3 x Blind rivet 5.2 x 14 Supporting element 15 Distance tube *Fixing method in the edge area usually up to 2 m wide. The necessity of additional fixing is determined by fixings calculation. No.21/V-3/

8 2.3.3 Panel to Panel Junction Fig. 10: Panel to panel junction detail 1 Panel beam-closing element 2 Dripping edge of a panel 3 Sealing tape 3 x 15 4 Self-tapping screw 5 Thermal insulation 6 Bulb tite rivet 5.2 x Panel mask 8 Blind rivet 4 x 10 * Fixing method in the edge area usually in a width of up to 2 m. The necessity of additional fixing is determined by fixing calculation Top End Support Fig. 11: Detail of fixing to the top end support h 800 mm (when loading by wind up to 0.8 kn/m 2 or with respect to static calculation) * Fixing method in the edge area is usually up to 2 m wide. The necessity of additional fixing is determined by fixing calculation. 1 Parapet cap 2 Closing profile 3 Blind rivet x 4 Self-tapping screw x 5 Flashing 6 Self-tapping screw x 7 Roof flashing 8 Tapping screw x 9 Thermal insulation 10 Butyl sealing tape 2 x 6 11 Sealing tape 3 x15 12 Supporting element 13 Blind rivet 5.2 x 14 Roof mask - gable - B 15 Roof mask - gable A 16 Corner profile 17 Self-tapping screw 18 Support flashing 19 Support flashing 20 Distance tube 6 No.21/V-3/

9 L 2.4 Panel Fixing Only screws made of stainless steel without round washers and with specially designed supporting elements (Fig. 5) can be used for fixing panels in the joint. Minimal screw thickness is 6.3 mm (Fig. 12 Item 2). For fixing through a panel (end supports) only screws made of stainless steel (Fig. 13 Item 4) should be used with 19 mm stainless steel washers and bonded EPDM seal. Fig. 12: Façade fixing detail Fig. 13: Detail of fixing through a panel 1 Trimoterm FTV INVISIO panel 2 Self-tapping screw x without washer 3 Adjusment element 4 Self-tapping screw x 5 Distance tube The length of a screw depends on the thickness of Trimoterm FTV INVISIO panel and type of substructure in accordance with the screw producer instructions (Table 3). Care should be taken when tightening screws to ensure they are not too loose or too tight. A distance tube (Fig. 1, 12 and 14) is to be inserted in a joint of a panel, or fixing place. The length of a distance tube depends on the panel thickness (Table 3). The distance tube is an item available from Trimo. Table 3: Type and length of a screw depending on panel and substructure thickness Panel thickness (mm) Fixing thickness for end support x L (Fig.13) Fixing thickness x L (Fig.12) 64 (7) (13) (3) (10) (5) x L Table 4: Distance tube lengths depending on panel thickness Panel thickness (mm) Length of a distance pipe L (mm) Fig. 14: Distance tube Fig. 15: Fixing screw types 10 type A type B type C 3 16 Notes: - All dimensions are stated in millimetres (mm). - Screws with a diameter of 6.5 mm are used for a substructure thickness up to 3 mm. - Data in brackets referring to screws 6.3 x L are thicknesses of the steel structure into which they can be fixed using the first screw length stated. For a thicker substructure the second length stated applies. - Lengths apply to screw types that are similar to those produced by SFS Stader, END - Self-tapping screws of type A (Fig.15) are used for fixing to thin steel purlins (steel thickness up to 3 mm). - Self-tapping screws of type B (Fig.15) are used for fixing to steel purlins (steel thickness of 3 mm and more). - Self-drilling screws of type C (Fig.15) are also used for fixing to steel purlins (steel thickness up to 12 mm). No.21/V-3/

10 Screws of types A and B are used for fixing to a steel substructure; a hole of a suitable diameter is to be drilled thought a panel and substructure in accordance with the instructions of the screw producer. Table 5 presents examples of required hole sizes by the producer SFS Stadler. Preliminary drilling of boreholes is not allowed for screws of type C. Table 5: Borehole diameter depending on substructure thickness Substructure thickness [ mm ] Borehole diameter [ mm ] (type A ) > Assembly Instructions 3.1 Installation Recommendations Trimoterm FTV INVISIO panels are suitable for vertical façades (Fig. 16). Fig. 16: FTV INVISIO cladding system Minimal intermediate support width for panels is 60 mm and on the end support 40 mm or depending on the static calculation (Fig. 17). Mineral wool in longitudinal sides of panels is protected by a self-adhesive tape (Fig. 18a). The tape does not need to be removed before the assembly. Fig. 17: Width of a support for panel overlying Fig. 18a: Presentation of protection on panel sides End support Intermediate support 8 No.21/V-3/

11 Trimoterm FTV INVISIO panels have a protective foil fixed on the top and bottom sides to protect its varnished surfaces against any possible damage during transport, handling and assembly. The foil should be removed from the internal side before the assembly of an individual panel. The foil on the external side should be removed immediately after the work has been finished. If necessary, the foil can be removed during assembly (e.g. in a longitudinal joint of two panels, under screws, flashing etc. Fig. 18b). Fig. 18b: Removal of a protective foil If panels are stored for a longer period of time, the foil is to be removed after three months at the latest. When storing panels in the open air, they are to be protected against the sun; otherwise removal of the foil may be difficult. When panels are cut during the assembly, only scissors and saws that do not heat the cutting edge to a high temperature (Fig. 19) may be used. High temperature can destroy the anticorrosive protection in the immediate vicinity of a cut. Therefore use of grinding machines is prohibited for such purposes! All small metal particles that appear as a consequence of cutting and drilling are to be immediately removed from the surface of panels, or at the latest when the daily work has been finished. Welding in the direct vicinity of panels may damage the anticorrosive protection. Fig. 19: Devices allowed for panel cutting Marking or scratching with nails or similar sharp objects that can damage the protective coat layer is prohibited. 3.2 Sealing During the assembly special attention is to be paid to tight fitting of panels. There should be no space in the longitudinal joint between the neighbouring panels (Fig. 20). Fig. 20: Tight fitting of panels No.21/V-3/

12 Sealing of longitudinal joints between Trimoterm FTV INVISIO panels is described in detail in Trimo Technical Document No. 3 Sealing of Trimoterm FTV panels is carried out regarding construction and physical conditions. When it is necessary that a seal (Fig. 21 and 22) is inserted in the longitudinal joint in the inner (warm) façade side; the seal is to be inserted at the stage of panel production. As a rule, a panel is delivered with a seal inserted. Fig. 21: Position of a seal Fig. 22: Method of inserting a seal in a panel Seal If butyl or silicone mastic seal is to be placed into the longitudinal joint, it should be applied in a way presented in Fig. 23 and 24. Mastic seal is placed in an individual joint before the assembly of the following panel. Fig. 23: Insertion of mastic seal in a panel Fig. 24: Detail of inserting mastic seal in a panel Points of installation for other sealing materials are evident from Trimo Standard details. 3.3 Lifting Methods The assembly begins in the end axis of an individual façade. Before the panels instalation begins, it is necessary to check the geometry of the substructure for accuracy, which is a pre-condition for quality performance. If there are irregularities in the geometry it is necessary to correct them by suitable cutting of the beginning and closing panels. The panels are leaned on the foundation angular steel that partly transfers vertical loads. For vertical façades the use of vacuum grippers (Fig. 25) is recommended for lifting the panels and putting them in place at the site of installation. On places where a vacuum gripper sucks on the panel, the protective foil should be removed from the panel before lifting. The use of mechanical grippers (Fig. 26 and 27) is also possible for vertical façades. Dimensions of the gripper and pins are to be statically determined relating to thickness and weight of panels. Fig. 25: Mechanical grippers 10 No.21/V-3/

13 Fig. 26: Lifting of panels using vacuum grippers Fig. 27: Lifting of panels using mechanical grippers Grippers with φ 12 mm pins should be used for lifting panels of 60, 80, 100 mm thickness, and grippers with φ 16 mm pins are used for panels thicker than 100 mm (Table 6). Boreholes for pins are made on spots that are subsequently covered by flashing. Table 6: Gripper types for individual thickness of a panel FTV INVISIO Gripper type 1 60 PVF PVF PVF PVF PVF PVF * PVF Gripper for Trimoterm FTV INVISIO vertical façade 3.4 Installation Details Fixing to an Intermediate Support Panels are fixed to intermediate supports through side lap joint using specially designed washers (Fig. 5 and 28). When fixing by two screws is necessary in the edge area, a purlin is upgraded by an expansion element (Fig. 29 and 30). A distance tube should be inserted in the panel, on fixing spots in the joint (Fig. 1, 14 and 28). Length of the distance tube depends on panel thickness (Table 4). Sequence of panel fixing to an intermediate support: - Drilling of a borehole for a screw in a joint through a panel and substructure (diameter of a bore hole is deter mined in Table 5). - Drilling of φ 10 mm borehole through steel sheet on the external side of the panel and wool up to the sheet metal on the rear side. - Insertion of a distance tube (Fig. 14) into the panel. A cut in the distance tube is parallel to the external edge of the panel (Fig. 4). - Insertion of the underlying element in the joint and fixing of the panel onto the substructure. A distance tube enables correct and even fixing of all panels to the joint. No.21/V-3/

14 Fig. 28: Detail of fixing to an intermediate support Fig. 29: Detail of fixing to a too short intermediate support Fig. 30: View of fixing to an intermediate support Type A Type B 1 Self-tapping screw x 2 Supporting element 3 Expansion element 4 Self-tapping screw 6.3 x 5 Distance tube Connection to the main beam Connection of a façade to the main beam The assembly begins in the buildings end axis. Before the first panel is fixed, the accuracy of the substructure geometry and the façade length should be checked. If the length is mm shorter than the multiplier of the Trimoterm FTV panel (module width is 1000 mm), it is recommended first to cut the panel longitudinally to a suitable length so that the façade begins and ends by approximately the same width of the panel. Fig. 31: Detail of a connection to the main beam 1 Self-tapping screw 2 Trimoterm FTV INVISIO panel 3 Sealing tape 3 x15 4 Blind rivet 4 x 8 stainless steel 5 Sealing tape EPDM 2 x 30 x100 6 Dripping edge flashing 7 Dripping edge of a panel 8 Supporting angle rail 9 Anchor bolt 10 Dripping edge flashing support Assembly sequence (Fig. 31): - Before assembly of an individual panel a cut should be made in the mineral wool approx. 2 mm wide, 30 mm from the external side and mm deep. The cut is needed for the performance of a drip flashing (Fig. 31). It is to be made by a circular saw or a knife using a suitable guiding device. - The panel beam-closing element (Item 8) is riveted to the concrete main beam and serves as a horizontal levelling. - Sealing tape 3 x 15 is fixed to the Item 8. - The dripp flashing (Item 7) is put under the first panel that is mounted. The panel is put on a suitable place, leaned on the angular steel (Item 8), levelled relating to the substructure and fixed. The number of screws for fixing through a panel is determined by calculation. - When the assembly has been finished, the dripp flashing support (Item 10) is riveted to the panels, i.e. one support to each panel. Sealing tape EPDM 2 x 30 x 100 mm is preliminary fixed to each beam of the flashing and riveted by two 4 x 8 rivets (Item 4). - Flashing of the dripping edge (Item 6) is put on the beam of the flashing support and then fixed by a 4 x 8 rivet (Item 4). 12 No.21/V-3/

15 Drip Flashing Extension Detail The extension is achieved by a 50 mm overlap using adhesive mastic seal in three lines as shown in Fig. 32. Fig. 32: Drip flashing extension Adhesive mastic seal Drip flashing extension Overlap Dripp Flashing Cut for Water Outlet Fig. 33 presents a water outlet that is made during the assembly. The rear part of the flashing should be cut out at approx. every 2 m. Fig. 33: Drip flashing cut for water outlet Drip flashing The rear part of the drip flashing should be cut out at approx. every 2 m External Corner Fig. 34: Detail of a external corner 1 External corner flashing 2 Sealing tape EPDM 2 x 47 3 Sealing tape 3 x 15 4 Thermal insulation 5 Self-tapping screw x 6 Blind rivet 4 x 10 7 Corner beam No.21/V-3/

16 Fig. 35: Performance panel beam closing element in the corner Fig. 36: Performance of a dripping edge in the corner Cross-section A - A Panel beam - closing element Anchor bolt Dripping edge Main beam Dripping edge Blind rivet 4 x 8 stainless steel Adhesive mastic seal Assembly sequence: - External corner flashing can be sharp-edged or rounded-off with a radius R = 80 mm (Fig. 34). - A beam panel beam-closing element is fixed to the main beam using anchors (Fig. 35). The foundation dripping edge of the panel is then riveted to it. The closing element in the corner is carried out by a 20 mm overlapping (Fig. 36). It is fixed by means of stainless steel blind rivet 4 8 mm. The joint is sealed using sealing-adhesive mastic seal. The vertical line is sealed in the central and rear part of the dripping edge. - The dripping edge should be cut in the corner when assembling the rounded-off corner flashing. - First, an angular steel is placed on the façade profiles and temporary fixed (e.g. welded) to the façade profiles. A sealing tape made of foamed polyethylene or foamed PVC 3 x 15 mm (Fig Item 3) is pre-applied put on it. - A panel is placed on the first façade and fixed. The second panel is placed slightly over the surface of façade profiles of the first façade. The space between the panels should be filled with mineral wool of good compression (Fig Item 4). - Rounded-off corner masks should be cut 15 mm at an angle of 45 (Fig. 34) on the second panel during the assembly. - A beam of the corner mask is riveted from the foundation to the parapet by at least 3 rivets/m before the external corner mask is assembled. Sealing tape EPDM 2 x 30 (Fig. 37 and 38) is pre-applied to the beam of the corner mask. - External corner flashing of the panel is placed in the corner and riveted by min. 2 rivets/m on each edge (Fig. 39 and 40). The corner flashing is levelled with the bottom edge of the foundation dripping edge and riveted from the side to the beam of the corner mask by min. 2 rivets/m. The corner flashing should be cut in the drip section because of the dripping edge. Extension of the mask on the external side should be carried out by an overlap of minimum 50 mm (Fig. 41). - Riveting of flashing in the bottom dripping edge follows. The flashing in the bottom dripping edge is to be laid up to the corner flashing. Preliminary, the flashing is to be cut at an angle of 15. WARNING: Some form of protection (e.g. cardboard, etc.) should be placed between the drilling machine and the façade panel when drilling and riveting the flashing to prevent damage to the panel. Fig. 37: Performance of a façade corner Fig. 38: Flashing beam Beam of a corner mask Panel beamclosing element EPDM seal Flashing beam Blind rivet Flashing beam Dripping edge of a panel Main beam Rivets 14 No.21/V-3/

17 Fig. 39: Fixing of a corner flashing in a panel Fig. 40: Performance of flashing in dripping edge Fig. 41: External corner flashing External corner flashing Blind rivet 4 x 8 stainless steel External corner element of a panel Overlap 50 mm Drip flashing Corners with a Pre-fabricated Corner Panels A pre-fabricated rounded off (Fig. 42) or sharp-edged longitudinal corner can be made of Trimoterm INVISIO panels (Fig. 42). The corner is fixed using a bespoke aluminium fixing profile to the concrete or steel structure. The sum of side lengths in the rounded-off corner is max A + B = 980 mm. Fig. 42: Detail of a preformed rounded-off corner 1 HF3 aluminium profile 2 Sealing tape EPDM 6 x 30 3 Self- tapping screw x 4 Thermal insulation 5 Fixing element 6 Self-tapping screw x 7 Bulb tite rivet x 8 Sealing tape 3 x 15 9 Corner element 10 Bulb tite rivet x Notes: - At least 50 mm of the longitudinal panel edge should be cut on both sides of the rounded-off corner, as well as on the edges of both neighbouring panels. - Possible angle of corner bending α = Rounded-off corners can be carried out only on façade panels that have micro-lined sheet metal on the external side. Fig. 43 presents the assembly of a parapet of a rounded-off corner and a dripping edge. The parapet of the rounded-off corner is inserted in the top of the rounded-off corner and sealed twice by adhesive mastic seal. Then the parapet cap is inserted and at least 50 mm of the parapet of the rounded-off corner is covered. Fixing of the parapet cap and the parapet of the rounded-off corner follows. Flashing of the corner dripping edge is inserted in the longitudinal flashing of the dripping edge and fixed by 4 x 8 - stainless steel blind rivets. No.21/V-3/

18 Fig. 43: Performance of a rounded-off corner parapet 1 Parapet of a rounded-off corner 2 Flashing of a dripping edge in the corner 3 Mastic seal 4 Self-tapping screw x 5 Blind rivet x Extension of a Façade For higher façades a façade extension detail is required (max. panel length is 14 m). Extension is carried out on an expanded or double purlin (Fig. 44). Minimum width of a support shall be 120 mm. Assembly sequence (Fig. 44): - First, sealing tape (Item 3) is applied to the façade profiles. The bottom row of Trimoterm FTV INVISIO façade panels is fixed. - Panel beam-closing element (Item 1) is riveted. Soft mineral wool (Item 5) should be inserted between the panel beam-closing element and the bottom panel. - Before the assembly of each top panel begins, cuts should be made in mineral wool of a dripping edge in a minimum width of 2 mm, 30 mm from the external side and mm deep, to accomodate drip flashing. - When assembling the first top panel a dripping edge (Item 2). is placed underneath. The panel with the dripping edge is placed in a suitable position, leaned on support angle rail (Item 1), levelled relating to the substructure and fixed. Care should be taken to ensure the screw does not make a hole in the dripping edge. The dripping edge is riveted to the top edge of the bottom panel. Extension of the dripping edge is to be carried out by an overlap and then fixed by mastic seal (Fig. 32). - An extension mask is put on the dripping edge (Item 7) and fixed to the bottom edge of the top panel by a 4 x 8 blind rivet (Item 8). Fig. 44: Detail of façade extension 1 Beam of the panel-closing element 2 Drip flashing 3 Sealing tape 3 x 15 4 Self-tapping screw 5 Thermal insulation 6 Bulb tite rivet 5.2 x Drip flashing mask 8 Blind rivet 4 x No.21/V-3/

19 3.4.6 Parapet Assembly sequence: - Panels are side lap fixed by use of supporting elements (Item 1) and distance tube (Item 5). - Closing profiles, 2 mm thick (Fig. 45 Item 4) are riveted to the top of panels in their longitudinal direction. - A parapet cap (Item 3) is put on the closing profile; the cap is to be fixed to the top of the closing profile by self-tapping screws. Fig. 45: Parapet detail Fig. 46: View of the parapet and valley gutter 1 Self-tapping screw 2 Blind rivet 3 Sealing tape 4 Parapet cap 5 Parapet cap carrier 6 Supporting element 7 Distance tube 8 Self-tapping screw Due to condensation problems it is recomended that downpipes be insulted Window Installation Before installing a window the bottom and top dripping edges are arranged as shown in Fig. 47. An 80 mm slot should be made in the top corner of the opening. Fig. 48 shows the installation of the top dripping edge in the slot (Detail A). A flap of 5 mm in height should be made in the top dripping edge to prevent water penetration from the end of the dripping edge into the panel. At the end of the slot the opening is sealed by adhesive mastic seal. Fig. 50 presents Detail B from Fig. 47. The bottom dripping edge should be adjusted to the form of the window opening. Flaps are made in a height of approx. 15 mm. A critical section on the part cut should be urgently sealed by sealing adhesive putty up to a height of 5 mm. Fig. 47: Performance of window dripping edges and flashing Flashing support of the top dripping edge point-wise or in complete length Closing flashing support Clossing flashing support Blind rivet 4 x 8 stainless steel Bottom dripping edge No.21/V-3/

20 Before the window is assembled, the bottom dripping edge should be fixed to the beam of the window opening fixed by stainless steel blind rivets 4 8 mm. Before the assembly of the bottom dripping edge the beam of the bottom dripping edge should be riveted by two rivets per meter, if there is a point-like element or at each 30 cm, if the element s length equals the length of the opening. Fig. 49 presents closing of the bottom dripping edge from the end. The hole is closed by the over-dimension of the flashing. After the top dripping edge has been mounted, the window can be installed (Fig. 51). Fig. 48: Detail of installing the top dripping edge Detail A Flap approx. 5 mm Adhesive mastic seal Slot approx. 80 x 5 Top dripping edge The closing flashing is fixed last. Before the closing flashing is mounted, the support of the closing flashing is riveted in the complete width of the window; seal EPDM 2 x 30 (Fig. 47) is fixed to it. When the window has been installed, a mask of the top dripping edge is installed, if necessary. Fig. 49: Closing of the bottom dripping edge Fig. 50: Detail of installing a bottom dripping edge Detail B Closing flashing Adhesive mastic seal Blind rivet 4 x 8 stainless steel Flap approx. 15 mm Bottom dripping edge Fig. 51: External view of a window Blind rivet 4 x 8 stainless steel Flashing of the top dripping edge Closing window flashing Window Bottom dripping edge Adhesive mastic seal Closing window flashing 18 No.21/V-3/

21 4.0 Packing, Transport and Storing 4.1 Packing Typically, panels are packed in stacks of height ranging from 200 to 1200 mm (Fig. 52). A stack of panels is loaded on to a Styro-foam base to a height of 100 mm. Varnished surfaces of panels are protected by a self-adhesive protective foil that should be removed at the individual panel assembly stage. A stack of panels is protected by cardboard; wrapping by a stretchable machine packing foil ensures its water tightness. Possible packing methods: - packing for a road transport, - packing for combined - road & railway transport, - packing for railway transport. Maximum dimensions of stacks including packaging: - width: 1195 mm, - height: 1320 mm, - length: mm, - weight: 3500 kg. Fig. 52: Side view of a stack Panels and all protective elements are wrapped in a packing foil. Cover Corner element distance piece Labels Front side Handling instructions Styro-foam Detailed information about packing is contained in Trimo Technical Document 9 Packing, transport and storing of Trimoterm FTV INVISIO façade panels. Instructions are available on the Internet ( 4.2 Transport Transport of Trimoterm FTV INVISIO façade from the factory to a building site is carried out by trucks or rail. The load should be fixed on a means of transport by fabric carrying belts. A lift or crane truck can be used for carrying of stacks and a fork lift truck for the transport of stacks shorter than 6 m. Moving or pushing of stacks by fork points or use of steel wires for carrying stacks with a crane is not allowed; only load bearing belts of suitable load-bearing capacity can be used for crane handling. Special attention is to be paid to the centre of gravity, since it should be between the forks or the load bearing belts. Only one stack may be carried at a time! When unloading a truck the truck tarpaulin should be completely removed from the vehicle. The carrying frame of the tarpaulin should also be completely (also from sides) removed so that panels cannot get damaged when lifted. WARNINGS: - Only one stack may be carried at a time. - Off-loading and site manupulation by a forklift truck is allowed only for stacks of a length up to 6 m. - Lifting by all kinds of cranes should always be carried out with fabric carrying belts. - Unloading instructions for handling are to be strictly followed. They are attached to a stack and any other handling can easily cause damage. - When stacks are received on a building site a recipient is obliged to complain about all visible defects to a driver. No.21/V-3/

22 4.3 Storage When storing Trimoterm FTV INVISIO panels the following is to be considered: - It is recommended that the stacks be stored in their original packaging, which ensures suitable water tightness. - When storing panels in the open air, a cardboard cover protects them against the sun; if there is no cover, it may be difficult to remove the protective foil. It is recommended that the foil be removed after three months. - Stacks are to be arranged on the flat and solid ground so that a stack cannot sink under its own weight and slip to the ground which is especially dangerous in winter when ice can collect on the foil. - Possible ways of arranging stacks are presented in Fig. 53. Fig. 53: Arranging stacks for storing Low stacks High stacks 20 No.21/V-3/

23 5.0 Maintenance 5.1 Annual Checking of a Façade In accordance with desirable practice it is necessary to check a façade and the complete building at least once a year. The purpose of checking is elimination of any possible shortcomings and extending of the façade s life time. Annual checking includes: - Cleaning of all dirt collected on the façade and if necessary, washing of the façade. It is recommended that the façade be washed once a year by a soft brush. If necessary a mild cleaning agent can be added (ph 6-7, concentration max. 10 %). The façade is washed from top to bottom by running water. - Damage caused to the façade is to be repaired immediately when it appears or it is observed. The location of damaged places is to be mechanically cleaned by a fine abrasive agent (Scotch breit M600). Removal of dust and grease follows (cleaning alcohol, isopropyl alcohol). Then a primer coating is applied by a brush (an air-dried coat based on epoxy fixing agent and Zn pigments). At the end final coating is also applied by a brush (an air-dried coat based on polyurethane or acrylic fixing agent). 5.2 General Recommendations The use of any aggressive substances for façade cleaning is prohibited due to possibility of damage of anticorrosive colour coating. Use of a rotating grinding machine (cutting machine) in the vicinity of the Trimo façading is prohibited since hot parts can damage the coating. If there are any questions relating to maintenance of a building or if repairs of defects or damage are needed, you are kindly asked to consult Trimo Service department. No.21/V-3/

24 Published by: TRIMO d.d., Design: Meta Gabrijel, Photography: Janez Erjavec, Miran Kambič, Printed by: Petrič, Circulation: 3000/EN, 07/2008

Inclined Roof System Trimoterm SNV

Inclined Roof System Trimoterm SNV Inclined Roof System Trimoterm SNV Inclined Roof System Trimoterm SNV - Technical Document EN Version 6 July 2016 TABLE OF CONTENTS 1 Technical Description of Roof System Trimoterm SNV 1 1.1 General 1

More information

Façade System Trimoterm FTV INVISIO

Façade System Trimoterm FTV INVISIO Façade System Trimoterm FTV INVISIO Façade System Trimoterm FTV INVISIO - Technical Document EN Version December 0 TABLE OF CONTENTS Technical description of the Facade system with Hidden Fixing FTV INVISIO.

More information

INCLINED ROOF SYSTEM TRIMOTERM SNV

INCLINED ROOF SYSTEM TRIMOTERM SNV INCLINED ROOF SYSTEM TRIMOTERM SNV TABLE OF CONTENTS 1 Technical Description of Roof System Trimoterm SNV 1 1.1 General 1 1.2 Panel Profile 1 1.3 Panel Composition 2 1.4 Technical Data 2 1.4.1 Basic Technical

More information

PolyCarb has good resistance to many chemicals. Some chemicals may harm the PolyCarb sheets. Contact us when in doubt about any chemical.

PolyCarb has good resistance to many chemicals. Some chemicals may harm the PolyCarb sheets. Contact us when in doubt about any chemical. Polycarbonate Panels This manual provides the basic information for working with and installing PolyCarb sheets. Due to their hollow core, prior preparation is needed before the actual installation, with

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

lindab we simplify construction LindabSandwichPanels Installation instructions PIR Panels

lindab we simplify construction LindabSandwichPanels Installation instructions PIR Panels lindab we simplify construction LindabSandwichPanels Installation instructions PIR Panels Assembly instructions Before you start Check that the panel support structures are level. Position the packages

More information

CINTRALUX ALU BARREL VAULT EP 10/10

CINTRALUX ALU BARREL VAULT EP 10/10 CINTRALUX ALU BARREL VAULT EP 10/10 Installation instructions EN 14963 Artn 43984 E_MH_Cintralux EP 10/10 mm AG.PLASTICS QUALITY 1 Installation instructions Cintralux aluminium barrel vault: Cintralux

More information

Hoesch Arched Roof Installation guide

Hoesch Arched Roof Installation guide Table of contents page 1. General........................................................................................ 1 2. Safety hints......................................................................................

More information

MOUNTING INSTRUCTIONS CONCRETE PURLIN BRACKET

MOUNTING INSTRUCTIONS CONCRETE PURLIN BRACKET CONCRETE PURLIN BRACKET VERSION MARCH 2015 GENERAL INSTRUCTIONS Safety: Systems may only be installed and operated by properly trained and technically suitable people (i.e. MCS accredited installers).

More information

DUTCH GABLE FREESTANDING CARPORT

DUTCH GABLE FREESTANDING CARPORT DUTCH GABLE FREESTANDING CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building a FREESTANDING Outback DUTCH GABLE CARPORT BEFORE YOU START Carefully read these instructions. If

More information

Fastening material. Lindab 1. General information and theory 2. Safe 3. Silencers 4. Dampers & Measure units 5. Fire dampers & Smoke evacuation

Fastening material. Lindab 1. General information and theory 2. Safe 3. Silencers 4. Dampers & Measure units 5. Fire dampers & Smoke evacuation Fastening material Lindab General information and theory Safe Silencers Dampers & Measure units Fire dampers & Smoke evacuation Air valves Roof hoods Other circular products Transfer 0 Rectangular Flexible

More information

Installation Guide Simplicity 16. V2.9 Lu171117

Installation Guide Simplicity 16. V2.9 Lu171117 0845 869 6006 www.canoports.co.uk Installation Guide Simplicity 16 V2.9 Lu171117 Tools Required Below is a list of tools that you will require to install the Simplicity 16 Canopy or Carport. Cordless Drill

More information

Verge Flashing. Verge Flashing. Only use if flashings requirements can be site measured before ordering. Verge Clip

Verge Flashing. Verge Flashing. Only use if flashings requirements can be site measured before ordering. Verge Clip Tolerance Detail (recommended) Verge Closure Verge Channel Verge Clip Verge Flashing VERGE CHANNEL RIVETTED TO EUROSEAM AT APPROX 400MM CENTRES USING 4.8 X 12MM RIVETS. NB: DO NOT RIVET AT HALTER POSITION

More information

PRICE LIST - 6th February 2017

PRICE LIST - 6th February 2017 W: www.cladco.co.uk E: info@cladco.co.uk T: 01837 659901 F: 01837 659902 Cladco Profiles North Road Industrial Estate, North Road, Okehampton, Devon, EX20 1BQ. PRICE LIST - 6th February 2017 Colour coated

More information

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM

KEITH PANEL SYSTEMS FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM S Y S T E M D E T A I L S FUNDERMAX- MAX EXTERIOR EXPOSED FASTENER PRESSURE EQUALIZED WALL SYSTEM PAGE TITLE PAGE Table of Contents Fundermax Max Exterior Product Information Design and Installation Information

More information

Walls Fact Sheets. Partition Walls and Walls Cladding. Perforated Board. Sandwich Board

Walls Fact Sheets. Partition Walls and Walls Cladding. Perforated Board. Sandwich Board s Partition and Perforated Board Sandwich Board Please consult Viroc Technical File available at www.viroc.pt, on EN language, on Downloads page. Other Viroc Recommended Solutions files, organized by type

More information

How to operate (folding)

How to operate (folding) How to operate (folding) LEFT HAND STACKING OUTWARD OPENING How to operate (folding) RIGHT HAND STACKING OUTWARD OPENING LOCK BOTH LEVER HANDLE AND FLAT HANDLE UTILISING THE D-HANDLE LOCATED ABOVE THE

More information

SUPREME WALL GARDEN ASSEMBLY INSTRUCTIONS 24/08/16 www.hallsgreenhouses.com Please refer to website for the most up to date instructions. SAFETY WARNING 1. Always wear protective glasses, shoes, gloves

More information

Installation Manual for Gate Guard

Installation Manual for Gate Guard Installation Manual for Gate Guard Fast Opening Barrier Gate for Emergencies and Contra Flow Innovative safety technology from SGGT of Germany TABLE OF CONTENTS Page Number Preface 3 Introduction 3 System

More information

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02

GROWING BETTER THROUGH DESIGN. 6ft Lean-To LEAN-TO. Assembly Instructions 04/02 GROWING BETTER THROUGH DESIGN 6ft Lean-To LEAN-TO Assembly Instructions 04/02 6ft Lean-To Greenhouse Base Plan Introduction/Tools/Contents / / Contents This is a copy of our Lean-To greenhouse base plan.

More information

INSTALLATION INSTRUCTIONS TRI-VENT. energy for a better world

INSTALLATION INSTRUCTIONS TRI-VENT. energy for a better world energy for a better world INSTALLATION INSTRUCTIONS TRI-VENT The photovoltaic mounting system for trapezoidal sheet roofs Quick and easy installation Riveting instead of glueing Securing without screws

More information

T H E W A Y Y O U W A N T

T H E W A Y Y O U W A N T T H E W A Y Y O U W A N T SL/kal 18.11.1992 Location: WORK INSTRUCTION 1(2) LK75-910-002-EN Installation of a Fire Door with Screw Fastening Frame Changed: 2009-12-11 AE/KM 2009-12-11 AE 2009-12-11 KM

More information

Wall mounting with holding profile

Wall mounting with holding profile B Main profile C Edge profile D Wall spacer E Heradesign acoustic panel Edge distance max. 250 mm c Centre distance of basic section (see table) B max. 600 mm or 625 mm a Centre distance of spacer (see

More information

Installation Instructions

Installation Instructions Installation Instructions Roof edge trim profile Series TAG multi-piece aluminium profile Front face height: 250-1050 mm supplied with patented 4F brackets as standard height-adjustable, horizontally moveable,

More information

INSTALLATION GUIDE DECKING.

INSTALLATION GUIDE DECKING. INSTALLATION GUIDE DECKING www.ttp-online.de/resysta CONTENT LATEST TEST RESULT Classification C, DIN 51097: Features, made by, best skid-resistance properties and is eminently suitable for wet barefoot

More information

DW HORIZONTAL INSTALLATION

DW HORIZONTAL INSTALLATION AR-PJ-01-DW2H 2" HORIZONTAL PANEL JOINT AR-PJ-02-DW2H 2" VERTICAL PANEL JOINT AR-PJ-03-DW2H 3" HORIZONTAL PANEL JOINT AR-PJ-04-DW2H 3" VERTICAL PANEL JOINT AR-PJ-05-DW2H CUSTOM REVEAL AR-PJ-06-DW2H DW-2000S

More information

Installation of HORIZONT and HORIZONT HIGH pool enclosures

Installation of HORIZONT and HORIZONT HIGH pool enclosures Installation of HORIZONT and HORIZONT HIGH pool enclosures Rev. 19.10.2017 PARTS LIST Parts for rail installation: Rail screw 6 x 60 Plastic anchor 10 x 50 Rail connector Arrest wedge [R-L] Pop rivet 4

More information

INSTALLATION AN EXPLODED VIEW OF A TYPICAL BRETT MARTIN RAINWATER INSTALLATION RAINWATER PRODUCT GUIDE

INSTALLATION AN EXPLODED VIEW OF A TYPICAL BRETT MARTIN RAINWATER INSTALLATION RAINWATER PRODUCT GUIDE AN EXPLODED VIEW OF A TYPICAL BRETT MARTIN RAINWATER HANDLING Brett Martin Rainwater systems are light in weight and are therefore easy to handle. As with all other quality materials, Rainwater components

More information

Land Rover Defender 110 Station Wagon External Front-Internal Mid Roll Cage (L148) Fitting Instructions

Land Rover Defender 110 Station Wagon External Front-Internal Mid Roll Cage (L148) Fitting Instructions Land Rover Defender 110 Station Wagon External Front-Internal Mid Roll Cage (L148) Fitting Instructions Unwrap the roll cage and unpack the individual fitting kits. At this point it is recommended that

More information

SECTION SHEET METAL FLASHING AND TRIM

SECTION SHEET METAL FLASHING AND TRIM SECTION 07620 PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Formed roof drainage sheet metal fabrications. 2. Formed low-slope roof sheet metal fabrications. 1.2 SUBMITTALS A. Shop Drawings: Show

More information

Barofor Round System (polyester coated) Panels, Posts, Accessories

Barofor Round System (polyester coated) Panels, Posts, Accessories 1 Scope This Technical Data Sheet specifies the requirements for the Barofor Round System. The complete system exists of: Panels Posts Accessories such as fixation system and posts caps. Panels and posts

More information

KS42 MF SERIES - HORIZONTAL INSTALLATION

KS42 MF SERIES - HORIZONTAL INSTALLATION CI-DS-01-KSMF H CI-PJ-01-KSMF H CI-PJ-02-KSMF H CI-PJ-03-KSMF H CI-PJ-04-KSMF H CI-PJ-05-KSMF H CI-PJ-06-KSMF H CI-PJ-07-KSMF H CI-PJ-08-KSMF H CI-PJ-09-KSMF H CI-PJ-10-KSMF H CI-PJ-11-KSMF H CI-PJ-12-KSMF

More information

Construction details: Master-C type profiles and joints:

Construction details: Master-C type profiles and joints: Construction details: Master-C type profiles and joints: Master-C 3g 32 mm. (1 1/4 ) 1000 mm. (39 3/8 ) outer face inner face 10.5 fixing details: sealing washers shall be installed through a 2-3/8 x 1-9/16

More information

I N S TA L L AT I O N & M A I N T E N A N C E G U I D E

I N S TA L L AT I O N & M A I N T E N A N C E G U I D E I N S TA L L AT I O N & M A I N T E N A N C E G U I D E E N V I R O B U I L D. C O M + 4 4 ( 0 ) 2 0 8 0 8 8 4 8 8 8 Version 3.2 EnviroBuild 2018 C O N T E N T S Storage & Handling 03 Tools 04 Calculating

More information

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions Edgerail System Specification & Installation Instructions Hill & Smith, Inc 1000 Buckeye Park Road Columbus, Ohio 43207 Tel: 614-340-6294 Fax: 614-340-6296 www.hillandsmith.com Section A System Specification

More information

PAGE 1 OF 6 FITTING INSTRUCTIONS FOR CAMEC 4 RADIUS CORNER SLIMLINE WIND OUT WINDOW. Rev 3 change all cutout radiuses from 55mm to 68mm.

PAGE 1 OF 6 FITTING INSTRUCTIONS FOR CAMEC 4 RADIUS CORNER SLIMLINE WIND OUT WINDOW. Rev 3 change all cutout radiuses from 55mm to 68mm. PAGE 1 OF 6 FITTING INSTRUCTIONS FOR CAMEC 4 RADIUS CORNER SLIMLINE WIND OUT WINDOW Rev 3 change all cutout radiuses from 55mm to 68mm. PAGE 2 OF 6 1. To install Camec 4RC window correctly please follow

More information

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws. Sheet Steel Facts Fastener Guide for Sheet Steel Building Products August, 2003 Fastener Materials Fasteners are manufactured from several materials and coatings. For the purpose of this fact sheet, the

More information

Tuff-Rib Install Guide

Tuff-Rib Install Guide Install Guide bestbuymetalroof.com Page 2 of 27 Page 3 of 27 1. Page 4 2. a. Installation Guide b. Panel Squaring Pages 5, 6 Pages 7, 8 3. Pages 9, 10 4. a. Fascia (optional) b. Eave / 1.5x3.5 Angle c.

More information

User s Manual For CT Model IMB

User s Manual For CT Model IMB User s Manual For CT Model IMB 2 of (13) Contents: A. Introduction... 3 B. Steps on receipt and opening the cases... 3 C. Transportation and handling... 3 D. Unpacking the transformer... 4 E. Storage...

More information

INSTALLATION INSTRUCTIONS ROPE ASSEMBLIES FATZER AG WITH HYEND SOCKETS FOR FROM. Kai-J. Thiem (THK) Martin Bechtold (BEM)

INSTALLATION INSTRUCTIONS ROPE ASSEMBLIES FATZER AG WITH HYEND SOCKETS FOR FROM. Kai-J. Thiem (THK) Martin Bechtold (BEM) INSTALLATION INSTRUCTIONS FOR ROPE ASSEMBLIES WITH HYEND SOCKETS FROM FATZER AG Created Kai-J. Thiem (THK) Checked Martin Bechtold (BEM) Released Kai-J. Thiem (THK) Version 2.0 Date 30.08.2016 Proof of

More information

SHEET METAL FLASHING AND TRIM Christ on the Mountain

SHEET METAL FLASHING AND TRIM Christ on the Mountain SECTION 076200 - SHEET METAL FLASHING AND TRIM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Compatibly with the bumping of flashings and trim as identified in the Membrane Roofing Section 075000.

More information

LUXAR Anti reflective coated glass Handling Procedures for LUXAR

LUXAR Anti reflective coated glass Handling Procedures for LUXAR LUXAR Anti reflective coated glass Handling Procedures for LUXAR - 1-29.03.99 Table of contents 0. Introduction of LUXAR 1. Transportation / Packing 2. Storage 3. Handling / Cutting 4. Treatment 5. Washing

More information

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS

EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS External EXPOSED FASTENING SYSTEM WITH SCREWS OR RIVETS Parklex Facade may be installed using mechanical fasteners, such as screws or rivets. The panels are attached to vertical battens. In the event that

More information

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS GARDEN SHED Assembly Instructions Suitable for Models 6' Wide 8' Wide 0' Wide WITH VARYING DEPTHS GI0003 November 0 INSTALLATION ADVICE It's Not That Difficult! The construction of your shed isn't as complicated

More information

GLOSSARY OF TERMS SECTION 8

GLOSSARY OF TERMS SECTION 8 GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the

More information

Swift assembly guide

Swift assembly guide Swift assembly guide Download the assembly guide at www.scihighmodels.com/swift.pdf Sample kit shown with aluminium bells (available with the Deluxe kit) Shown here without main tanks Version 10/12/2010

More information

ALUMINUM PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy

More information

LED Thin Frame Fixed Frame Screen User Guide

LED Thin Frame Fixed Frame Screen User Guide LED Thin Frame Fixed Frame Screen User Guide INTRODUCTION INTRODUCTION WARNING - Sharp Edges This product may contain sharp edges, please handle with care. Protective gloves are recommended. WARNING -

More information

STEEL PIPE GUIDERAIL 01/01/

STEEL PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Pipe Rails and s shall be in accordance with ASTM A5 Grade B for standard weight pipe and ASTM A500 Grade B, C or D or ASTM A50 for structural tube. Bars for handrail supports

More information

50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated

50948-RHN Putney. 06 January This document includes: Aluminium strip/ sheet coverings/ flashings 1. Code Section Revision Dated 50948-RHN Putney 06 January 2018 This document includes: Code Section Revision Dated H72 Aluminium strip/ sheet coverings/ flashings 1 Table of Contents Title H72 Aluminium strip/ sheet coverings/ flashings

More information

Durabrac Gable Bracket Installation Guide

Durabrac Gable Bracket Installation Guide Durabrac Gable Bracket Installation Guide Durabrac vinyl gable brackets are manufactured from high quality natural white vinyl with UV inhibitors. There are currently six styles and three sizes to choose

More information

ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH

ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH RAFTER PREPERATION RAFTER PREPARATION A FRAME PREPERATION AND ASSEMBLY A FRAME PREPARATION AND ASSEMBLY... Open boxes, remove

More information

Five Star Panel Installation Instructions

Five Star Panel Installation Instructions Five Star Panel Installation Instructions How to Store Five Star Panels You will need to store FIVE STAR PANELS in dry place to prevent staining, deterioration and possibly void all warranties. Stand the

More information

900 SERIES WALL PANELS

900 SERIES WALL PANELS CI-DS-01-900 CI-PP-01-900 CI-PJ-01-900 CI-PJ-02-900 CI-PJ-03-900 CI-BS-01-900 CI-BS-02-900 CI-BS-03-900 CI-BS-04-900 CI-BS-05-900 CI-OC-01-900 CI-OC-02-900 CI-IC-01-900 CI-FO-01-900 CI-FO-02-900 CI-FO-03-900

More information

FischerTHERM plusdach The Sandwichelement with the special something

FischerTHERM plusdach The Sandwichelement with the special something The Sandwichelement with the special something Contents Page General Product Range 4 Fasteners 5 Secure fastening 7 Assembly 8 9 Details 0 References 4-5 FischerProfil 05 FischerTHERM plusdach The first

More information

W L. Standard Sizes: 2.125m underside of gutters m total height m roof m roof m roof.

W L. Standard Sizes: 2.125m underside of gutters m total height m roof m roof m roof. H Standard Sizes: H 2.125m underside of gutters. 2.280m total height. L L 5.450m roof. 6.050m roof. 7.250m roof. W W 3.000m roof/2.640m between posts. 3.600m roof/3.240m between posts. 5.400m roof/5.040m

More information

Installation Instructions

Installation Instructions Installation Instructions Alpha SolarSmart On Roof Kits for the Installation of Alpha Solar Collectors onto Tile and Slate Type Roofs For Technical help or for Service call... ALPHA HELPLINE Tel: 0 77

More information

SunTrackerTwo Preparation

SunTrackerTwo Preparation TOLL FREE:(888)29-2705 FAX:(941)77-9460 info@eco-smart.com SunTrackerTwo Preparation Cutting Holes and Preparing Curbs T.G.I Or Truss CIRALIGHT INSTALLATION MANUAL Page 1 Cutting Holes and Preparing Curbs

More information

PANEL FABRICATION PROCESS

PANEL FABRICATION PROCESS PANEL FABRICATION PROCESS PANEL FABRICATION MACHINE SPECIFICATIONS- FEATURES AND USAGE Features: Fabrication machine has the advantage of having a beautiful appearance, design, reliable quality, easy operating

More information

SpeedDeck. Fixing and Handling Guide

SpeedDeck. Fixing and Handling Guide SpeedDeck Section 1 Delivery/Storing On Site/Handling l SpeedDeck is factory or on-site manufactured. l Straight SpeedDeck bundles are a maximum 1 tonne, sheets nestled and banded with polypropylene or

More information

Installation Guide. Resysta Flooring. 15 Years Guarantee. swell-free crack-free splinter-free rot-free. Version 1 / July 2010 / English.

Installation Guide. Resysta Flooring. 15 Years Guarantee. swell-free crack-free splinter-free rot-free. Version 1 / July 2010 / English. Installation Guide Flooring 15 Years Guarantee swell-free crack-free splinter-free rot-free Flooring Version 1 / July 2010 / English 1 The Latest Test Result Classification C, DIN 51097: offers best skid-resistance

More information

Slide the stock rubber tank mount caps onto the ends of the CS-1 tank mount:

Slide the stock rubber tank mount caps onto the ends of the CS-1 tank mount: RYCA CS-1 BODY PARTS INSTALLATION GUIDE [The CS-1 installation guides should be used as supplements to the videos found on our Youtube Channel. There is no strict order to the build process, but it is

More information

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS

STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS STACKING MULTI-SLIDE DOOR SYSTEM INSTALLATION INSTRUCTIONS 1290363 Revision 1 12/16 Page 1 Weather Shield Mfg., Inc. NOTICE CAUTION! Failure to install and maintain our product according to these instructions

More information

Industrial and Transportation Business DISTRIBUTOR PRODUCT LINE

Industrial and Transportation Business DISTRIBUTOR PRODUCT LINE Industrial and Transportation Business DISTRIBUTOR PRODUCT LINE 3900 DUCT TAPE 3900 DUCT TAPE MRO (Maintenance and Repair) Construction Trade Shows and Conventions General Industrial Electrical Aerospace

More information

Installation instructions: Elements Vulcan+ Newport Hector Cladding

Installation instructions: Elements Vulcan+ Newport Hector Cladding Technical Data Wood Species Thermally Modified Softwood (Pinus Radiata) Images Profile Newport Hector - Light Band Sawn face - Secret fix 5.4 6.0 8.5 3.0 25.0 3.0 111.0 3.0 12.0 R 3.0 7.0 7.0 123.0 15.0

More information

Carousels - Overlapping Slat

Carousels - Overlapping Slat Carousels - Overlapping Slat Introduction The overlapping slat carousel is designed to re-circulate baggage through a series of rectangular shaped slats overlapped and linked to form a continuous loop.

More information

POOL ENCLOSURES LEIA & ALVA. Assembly manual

POOL ENCLOSURES LEIA & ALVA. Assembly manual POOL ENCLOSURES LEIA & ALVA Assembly manual Rev. 07.2017 PARTS LIST Parts for rail installation: Rail Síncsavar screw 1 Plastic Síncsavar anchor 10 50 2 Rail Síncsavar connector 3 Arrest Síncsavar wedge

More information

DW VERTICAL INSTALLATION

DW VERTICAL INSTALLATION AR-PJ-01-DW5V AR-PJ-02-DW5V AR-PJ-03-DW5V AR-PJ-04-DW5V AR-BS-01-DW5V AR-BS-02-DW5V AR-OC-01-DW5V AR-OC-02-DW5V AR-OC-03-DW5V AR-IC-01-DW5V AR-IC-02-DW5V AR-IC-03-DW5V AR-FO-01-DW5V AR-FO-02-DW5V AR-FO-03-DW5V

More information

Installation Manual. Last Updated 4 February, Postal PO Box 932 Bayswater VIC

Installation Manual. Last Updated 4 February, Postal PO Box 932 Bayswater VIC Installation Manual Last Updated 4 February, 2013 Part 1: Provided Material The Panel Expandable Foam Sealing Strip Barge Capping Z-Fascia Structural Screws Timber: 3/8 head size Metal: 5/16 head size

More information

Cabonyx Installation Manual

Cabonyx Installation Manual Cabonyx Installation Manual Content Deck-Nyx and Plan-Nyx Installation Page 1 Flooring Products Page 1 Accessories Page 1 Installation Tools Page 2 Preparing Sub-structure Page 2 Installation Page 4 Cautions

More information

HBS-AP ASSEMBLING INSTRUCTIONS

HBS-AP ASSEMBLING INSTRUCTIONS ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK - ALUMINIUM PIPEWORK 97 HBS-AP ASSEMBLING INSTRUCTIONS 1. INTRODUCTION 1.1. This manual is very easy to consult and we recommend reading it before starting work,

More information

Instructions for Installation on a Flat Roof

Instructions for Installation on a Flat Roof Lightway, s.r.o. Registered office: Ledvinova 1714, 149 00 Praha 4 Offices: Za Humny 1054/4a, 161 00 Praha 6 tel.: 235 300 694, fax: 235 300 218 Company ID No.: 63669366, Tax ID No.: CZ63669366 Bank: KB

More information

Instructions for Installation on a Pitched Roof LIGHTWAY optical tube LW 260, LW 320, LW 520, LW 760

Instructions for Installation on a Pitched Roof LIGHTWAY optical tube LW 260, LW 320, LW 520, LW 760 Lightway, s.r.o. Registered office: Ledvinova 1714, 149 00 Praha 4 Offices: Za Humny 1054/4a, 161 00 Praha 6 tel.: 235 300 694, fax: 235 300 218 Company ID No.: 63669366, Tax ID No.: CZ63669366 Bank: KB

More information

Installation Manual for Thermo Panel

Installation Manual for Thermo Panel Installation Manual for Thermo Panel 1 About Thermo Panel is a building wrap, insulation, air and water barrier, mold inhibitor and cold bridge eliminator all-in-one. Delivering an R-value of up to 5 on

More information

Polytegola N. Bitumen Roof shingles. Application guide

Polytegola N. Bitumen Roof shingles. Application guide Polytegola N Bitumen Roof shingles Application guide Application manual POLYTEGOLA N CONTENT 1. Foreword - General conditions 3 2. POLYTEGOLA N designs 4 3. Roof pitches 5 4. Storage 5 5. Roof decking

More information

Folding sliding doors

Folding sliding doors Folding sliding doors Standard program overview Folding sliding doors Folding sliding doors single and double-skinned Product Dimensions in mm width/height Leaf thickness Min. headroom Min. lateral projection

More information

ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS. Style A Style B Style C Style D

ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS. Style A Style B Style C Style D ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical

More information

CALME Installation Manual

CALME Installation Manual Installation Manual 1. Installation Methods..2 (1) Installation with screws or rivets (2) Installation with glue (3) Examples of installation (4) Installation of edges and corners 2. Curving, Cutting,

More information

Cembrit Patina. Cembrit Cover. Cembrit Solid. Cembrit Transparent

Cembrit Patina. Cembrit Cover. Cembrit Solid. Cembrit Transparent Rainscreen Cladding Your choice. In addition to the range of colours and shades, Cembrit cladding boards are available in four compositions, each with distinctive performance and characteristics. Cembrit

More information

Assembly instructions

Assembly instructions Assembly instructions Plannja Profiles 20 105, 20 75, Sinus 18, Sinus 51, 45, 45R, 19R, 35 including flashings and fittings 2017 Roofing Sheet & Wall Cladding TABLE OF CONTENTS Some words of advice...

More information

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT TRADITIONAL GABLE ATTACHED PATIO AND CARPORT STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT BEFORE YOU START Carefully read

More information

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM). PART 1 - GENERAL 1.1 SECTION INCLUDES A. Benches. B. Trash receptacles. C. Bike storage. 1.2 REFERENCE STANDARDS A. Including but not limited to: 1. American Society for Testing and Materials (ASTM). 1.3

More information

CAVALIER. Shower Door Installation Instructions

CAVALIER. Shower Door Installation Instructions CAVALIER Shower Door Installation Instructions IMPORTANT DreamLine reserves the right to alter, modify or redesign products at any time without prior notice. For the latest up-to-date technical drawings,

More information

ANTTI MARINE. Antti Marine Doors Instructions ASENNUS_EN

ANTTI MARINE. Antti Marine Doors Instructions ASENNUS_EN Antti Marine Doors Instructions ASENNUS_EN ANTTI-TEOLLISUUS OY Koskentie 89 FIN-25340 Kanunki, Salo FINLAND Tel. +358 2 7744 700 Fax +358 2 7744 777 www.antti-teollisuus.fi Read the installation instructions

More information

Elara NanoEdge Fixed Frame Screen User Guide

Elara NanoEdge Fixed Frame Screen User Guide Elara NanoEdge Fixed Frame Screen User Guide INTRODUCTION INTRODUCTION WARNING This product may contain sharp edges, please handle with care. Protective gloves are recommended. A minimum of two people

More information

PAT installation of a Sun Dome over a in-ground

PAT installation of a Sun Dome over a in-ground PAT. 3766573 Installation of Sun Domes for in-ground pool GENERAL INSTRUCTIONS: STEP 1. Read thru the entire instructional materials before beginning any installation. You will find that the installation

More information

Installation Instructions

Installation Instructions Installation Instructions Öko Skin application as facade cladding Öko Skin concrete slats are installed as wall panels based on the principle of curtain-type, rear-ventilated facades. In order to ensure

More information

Assembly instructions

Assembly instructions Assembly instructions SF 55 / SF 55c SF 75 / SF 75c / SF 75H A B B C D Scope of delivery: Safety instructions: A. Top rail B. Vertical profile C. Floor rail D. Hinged panel, sliding panel Accessories pack

More information

Flex Fence Instruction Manual

Flex Fence Instruction Manual The Safer Stronger Smarter Choice Flex Fence Instruction Manual Table of contents 2 3 4 4 5 5 6 7 8 10 10 11 11 12 13 13 15 18 18 19 20 22 Table of contents Supplies, tools and equipment Introduction Laying

More information

ClicWall. Decorative wall covering

ClicWall. Decorative wall covering ClicWall Decorative wall covering ClicWall Installation guide Overview 1. Product description... 3 2. Dimensions and weight... 3 3. Transport... 3 4. Storage and installation conditions... 3 5. Installation

More information

3/ /

3/ / SUNGLAZE system is designed for both rafter and purlin construction options. Recommended minimum roof slope for Sunglaze applications is 5 o. Where lower slopes are necessary, we recommend rafter construction.

More information

Installation Guide Simplicity Alfresco. V1.9 Lu070318

Installation Guide Simplicity Alfresco. V1.9 Lu070318 0333 305 5272 www.canoports.co.uk Installation Guide Simplicity Alfresco V1.9 Lu070318 Tools Required Below is a list of tools that you will require to install your the Simplicity Alfresco System. Cordless

More information

Connect Transit Shelter

Connect Transit Shelter Tools Required *denotes special tools required Connect Shelter, 8ft Connect Shelter, 12ft *Soft, non abrasive protective surface such as a furniture blanket *Source of compressed air (for thorough dust

More information

Industrial Steel Sliding Doors

Industrial Steel Sliding Doors Industrial Steel Sliding Doors Exceptionally Robust and Extremely Efficient A wide range of different types and appearances Hörmann steel sliding doors can be supplied single and double-skinned in an overall

More information

INSTALLATION INSTRUCTIONS (for a sloping roof)

INSTALLATION INSTRUCTIONS (for a sloping roof) INSTALLATION INSTRUCTIONS (for a sloping roof) Tubular light tunnel ALLUX 250, 350, 550 (versions ALLUX Flexi or ALLUX Plus) 1. Dome (unbreakable polycarbonate) 2. Dome fixture 3. Nut for attaching the

More information

SILVERBACK INSTALLATION MANUAL

SILVERBACK INSTALLATION MANUAL SILVERBACK INSTALLATION MANUAL R-SERIES SOLAR RACKS T OLL FREE 866-766-3727 WWW.ROOFSCREEN.COM Introduction... 2 The Silverback Solar Racking System... 2 This manual... 2 Application... 2 System Overview...

More information

INSTALLATION GUIDE DUOFUSE SLAT WALL SYSTEM

INSTALLATION GUIDE DUOFUSE SLAT WALL SYSTEM 06/2013 ENG 1 INSTALLATION GUIDE DUOFUSE SLAT WALL SYSTEM The Duofuse wood composite slat wall system is much more durable than wooden fences, and correct installation is necessary to enjoy the fences

More information

How to make a template to mount your plaque to a surface

How to make a template to mount your plaque to a surface How to make a template to mount your plaque to a surface A piece of heavy paper 3 4 wider than your plaque on all four sides (paper grocery bag works great too) Small amount of paint (latex dries the fastest)

More information

The Leka System Installation Guide

The Leka System Installation Guide Installation Guide The Leka System Installation Guide The following guide has been created to assist in the fabrication and installation of the Leka System. Please note that each roof is individual and

More information

Care Instruction: Wash vehicle roof prior to installing Rhino Tracks.

Care Instruction: Wash vehicle roof prior to installing Rhino Tracks. Important: Please read these instructions carefully prior to installation. Please refer to your fitting instruction to ensure that the roof racks are installed in the correct locations. Check the contents

More information