1 FLUXUS Cryo Non-invasive flow measurement of cryogenic liquids FLUXUS Cryo extends the application range of the ultrasonic clamp-on flow measurement with WaveInjector Cryo to cryogenic temperatures up to -200 C. The patented mounting fixture thermally separates the ultrasonic transducers from the hot or cold pipe and at the same time ensures good acoustic contact. Therefore, FLXIM's standard transducers are suitable for long-term operation even at extremely cold temperatures. F721 Features Non-invasive measurement without contact to the fluid Fluid temperature range: C Transducers and mounting fixture can be fully integrated into the insulation Bidirectional measurement Paired and factory-calibrated transducers: no zeroizing necessary, excellent zero-point stability High repeatability of measurement results Highly reliable: maintenance-free, no moving or vibrating parts, dual-beam redundant measurement Operationally safe: no gaskets, no leakage points No pipework necessary for installation F801 Transmitters FLUXUS Cryo F809 Applications Flow measurement of: LNG Liquid ethane Liquid nitrogen Liquid oxygen Other cryogenic fluids Measurement with transducers mounted with WaveInjector Cryo Measurement with transducers mounted with WaveInjector Cryo and with insulation TSFLUXUS_CYO_V1-0N_Leu,

2 FLUXUS CYO Table of contents Typical measurement setup... 3 Flow transmitter F Technical data... 4 Dimensions " pipe mounting kit (optional)... 8 Terminal assignment... 9 Flow transmitter Technical data Dimensions Wall and 2 " pipe mounting kit Terminal assignment Flow transmitter F Technical data Dimensions Wall and 2 " pipe mounting kit Transducers Transducer selection Installation recommendation Technical data Transducer mounting fixture Coupling materials for transducers Connection systems Transducer cable Junction box Technical data Dimensions " pipe mounting kit (optional) Terminal assignment Transducer heating system (optional) Continous operation Cycle operation Technical data Insulation TSFLUXUS_CYO_ V1-0N_Leu,

3 FLUXUS Cryo Typical measurement setup transmitter JB0x JB0x transducer heating system power supply xample of a diagonal arrangement with 2 beams and transducer heating system TSFLUXUS_CYO_ V1-0N_Leu,

4 FLUXUS Cryo Flow transmitter F721 Technical data FLUXUS F721**-NNN*A F721**-NNN*S F721**-A20*S design standard field device field device with stainless steel housing measurement measurement principle flow velocity repeatability fluid temperature compensation accuracy 1 with standard calibration with advanced calibration (optional) with field calibration 2 flow transmitter power supply transit time difference correlation principle, automatic NoiseTrek selection for measurements with high gaseous or solid content m/s 0.15 % of reading ±0.01 m/s all acoustically conductive liquids with < 10 % gaseous or solid content in volume (transit time difference principle) corresponding to the recommendations in ANSI/ASM MFC ±1.6 % of reading ±0.01 m/s ±1.2 % of reading ±0.01 m/s ±0.5 % of reading ±0.01 m/s V/ Hz or V DC or V DC < 15 W 1, optional: 2 power consumption number of flow measuring channels damping s, adjustable measuring cycle (1 channel) Hz response time 1 s (1 channel), option: 20 ms housing material aluminum, powder coated stainless steel 316L (1.4404) degree of protection according IP66 IP66 to IC/N dimensions see dimensional drawing weight 5.4 kg 5.1 kg fixation wall mounting, optional: 2 " pipe mounting ambient temperature C (< -20 C without operation of the display) display 128 x 64 dots, backlight menu language nglish, German, French, Dutch, Spanish, Russian, Polish explosion protection transmitter - F721**-A20*S zone - 2 marking - II3G A T X II2D x na nc ic IIC T4 Gc x tb IIIC T 120 C Db T a C certification - IBxU11ATX1015 type of protection - gas: non sparking dust: protection by enclosure 1 for transit time difference principle, reference conditions and v > 0.15 m/s 2 reference uncertainty < 0.2 % 4 TSFLUXUS_CYO_ V1-0N_Leu,

5 FLUXUS Cryo FLUXUS F721**-NNN*A F721**-NNN*S F721**-A20*S measuring functions physical quantities totalizer calculation functions diagnostic functions data logger loggable values capacity communication (optional) service/diagnosis3 process integration (max. 1 optional) volumetric flow rate, mass flow rate, flow velocity, heat flow (if temperature inputs are installed) volume, mass, optional: heat quantity average, difference, sum (2 measuring channels necessary) sound speed, signal amplitude, SNR, SCNR, standard deviation of amplitudes and transit times all physical quantities, totalized values and diagnostic values max measured values measured value transmission, parametrization of the transmitter: -USB - thernet - BACnet MS/TP - BACnet IP (nonx) - M-Bus (nonx) - RS485 (ASCII sender) including parametrization of the transmitter: - Modbus RTU - Modbus TCP (nonx) -HART - Profibus PA -FF H1 serial data kit (optional) software FluxDiag: online diagnostics and report generation (min. Windows 7) сable USB cable3 outputs (optional) The outputs are galvanically isolated from the transmitter. number on request switchable current output All switchable current outputs are switched to active or passive mode at the same time. - range ma ( ma) - accuracy 0.04 % of reading ±3 μa - active output R ext < 350 Ω - passive output U ext = V, depending on R ext, R ext < 1 kω current output current output - range 0/ ma - accuracy 0.1 % of reading ±15 μa - active output R ext < 500 Ω - passive output U ext = V, depending on R ext, R ext < 1 kω current output I1 in HART mode - range ma - active output U int = 24 V - passive output U ext = V voltage output range V or V accuracy V: 0.1 % of reading ±1 mv V: 0.1 % of reading ±10 mv internal resistance R int = 500 Ω frequency output range khz open collector 24 V/4 ma, R int = 66.5 Ω binary output Reed relay 48 V/100 ma, R int = 22 Ω optorelay 26 V/100 ma binary output as alarm output - functions limit, change of flow direction or error binary output as pulse output mainly for totalizing - pulse value units - pulse width optorelay: ms Reed relay: ms 3 outside of explosive atmosphere (housing cover open) TSFLUXUS_CYO_ V1-0N_Leu,

6 FLUXUS Cryo FLUXUS F721**-NNN*A F721**-NNN*S F721**-A20*S inputs (optional) The inputs are galvanically isolated from the transmitter. number max. 4, on request temperature input type Pt100/Pt1000 connection 4-wire range C resolution 0.01 K accuracy ±0.01 % of reading ±0.03 K current input accuracy 0.1 % of reading ±10 μa active input U int = 24 V, R int = 50 Ω, P int < 0.5 W, not short-circuit proof - range ma passive input R int = 50 Ω, P int < 0.3 W - range ma voltage input range V accuracy 0.1 % of reading ±1 mv internal resistance R int = 1 MΩ binary input switching signal V, 1 ma functions - resetting the measured values - resetting the totalizers - stopping the totalizers - activation of the measuring mode for highly dynamic flows 6 TSFLUXUS_CYO_ V1-0N_Leu,

7 FLUXUS Cryo Dimensions FLUXUS F721**-****A 94 wall mount Ø Ø8.5 thread: 6x M20 x 1.5 cable gland: max. 6x M FLUXUS F721**-****S fixing holes for wall mounting 320 cable gland: max. 6x M20 with flat gasket and counter nut in mm TSFLUXUS_CYO_ V1-0N_Leu,

8 FLUXUS Cryo 2 " pipe mounting kit (optional) FLUXUS F721**-****A FLUXUS F721**-****S 8 TSFLUXUS_CYO_ V1-0N_Leu,

9 FLUXUS Cryo Terminal assignment FLUXUS F721 KL11 KL12 KL7 KL9 AV AVS AGN ARS AR BV BVS BGN BRS BR X_AV X_AR X_BV X_BR X2 X3 KL8 T1A T1B S1 T2A T2B T3A T3B T1a T1b S1 T2a T2b T3a T3b S3 T4A T4B S3 T4a T4b KL10 A+ B- P1+ P2+ P3+ P4+ P5a P6a P7a S S P1- P2- P3- P4- P5b P6b P7b KL4 P N(-) L(+) F721**-****S F721**-****A equipotential bonding terminal power supply terminal strip KL4 terminal connection (AC) connection (DC) P earth earth N(-) neutral - L(+) phase + transducers terminal strip KL11, KL12 extension cable (transducers *****8*, ****LI*, *****52) transducer cable (transducers *****52) transducer cable (transducers *****8*, ****LI*) measuring channel A measuring channel B measuring channel A measuring channel B terminal connection terminal connection terminal connection AV signal BV signal X_AV X_BV SMB connector AVS shield BVS shield X_AR X_BR SMB connector ARS shield BRS shield AR signal BR signal outputs 1 RS485, Modbus RTU, BACnet MS/ TP, Profibus, FF H1, M-Bus (optional) terminal strip KL9, KL10 terminal strip KL9, KL10 terminal connection terminal connection P1+...P4+, P1-...P4- current output, voltage output, frequency output, binary output A+ signal + (Reed relay) P5a...P7a, P5b...P7b binary output (optorelay) B- signal - S shield analog inputs 1 terminal strip KL7, KL8 temperature probe passive current source active current source terminal direct connection connection with extension cable connection of an active input connection of a passive input T1a...T4a red red not connected not connected T1A...T4A red/blue grey - + T1b...T4b white/blue blue + not connected T1B...T4B white white not connected - S1, S3 shield shield not connected not connected binary inputs 1 terminal strip KL9, KL10 terminal P1+...P2+, P1-...P2-1 The number, type and terminal assignment of the outputs and inputs will be customized. TSFLUXUS_CYO_ V1-0N_Leu,

10 FLUXUS Cryo Flow transmitter Technical data FLUXUS F801**-A10 F801C24 model code F801**-A10****-*A F801**-A10****-FF F801**-A1B F801**-A10****-*P design explosion proof offshore device measurement measurement principle flow velocity repeatability fluid temperature compensation accuracy 1 with standard calibration with advanced calibration (optional) with field calibration 2 flow transmitter power supply A T X / I C x transit time difference correlation principle, automatic NoiseTrek selection for measurements with high gaseous or solid content m/s 0.15 % of reading ±0.01 m/s all acoustically conductive liquids with < 10 % gaseous or solid content in volume (transit time difference principle) corresponding to the recommendations in ANSI/ASM MFC ±1.6 % of reading ±0.01 m/s ±1.2 % of reading ±0.01 m/s ±0.5 % of reading ±0.01 m/s V/ Hz or V DC or on request: V DC 24 V DC ±10 % power consumption < 8 W < 4 W number of flow measuring 1, optional: 2 channels damping s, adjustable measuring cycle (1 channel) Hz response time 1 s (1 channel), option: 70 ms housing material stainless steel 316/316L (1.4401, , ) degree of protection according IP66 to IC/N dimensions see dimensional drawing weight 6.6 kg fixation wall mounting, 2 " pipe mounting ambient temperature C C display 2 x 16 characters, dot matrix, backlight menu language nglish, German, French, Dutch, Spanish explosion protection zone 1 1 marking II2G II2D x d e IIC T6 Gb x tb IIIC T 100 C Db T a C II2G x d e [ib] IIC T4 Gb T a C certification ATX IBxU05ATX1078 IBxU05ATX1078 certification ICx ICx IB type of protection electronics compartment: flameproof enclosure connection compartment: increased safety intrinsic safety parameters - 1 for transit time difference principle, reference conditions and v > 0.15 m/s 2 reference uncertainty < 0.2 % electronics compartment: flameproof enclosure connection compartment: increased safety output circuits: intrinsic safety U m = 250 V AC intrinsically safe outputs: U i = 28.2 V P i = 0.76 W L i, C i negligible 10 TSFLUXUS_CYO_ V1-0N_Leu,

11 FLUXUS Cryo FLUXUS F801**-A10 F801C24 measuring functions physical quantities volumetric flow rate, mass flow rate, flow velocity totalizer volume, mass calculation functions average, difference, sum (2 measuring channels necessary) diagnostic functions sound speed, signal amplitude, SNR, SCNR, standard deviation of amplitudes and transit times data logger loggable values all physical quantities, totalized values and diagnostic values capacity > measured values communication interface - process integration (optional): - diagnosis: RS diagnosis: RS232 3 RS485 (sender) or Modbus RTU or HART - diagnosis: RS232 3 serial data kit (optional) software (all Windows versions) - FluxData: download of measurement data, graphical presentation, conversion to other formats (e.g. for xcel ) - FluxDiag (optional): online diagnostics and report generation - FluxSubstanceLoader: upload of fluid data sets сable RS232 3 adapter RS232 - USB 3 outputs (optional) The outputs are galvanically isolated from the transmitter. number current output: and binary output (open collector): or current output: and binary output (open collector): 1 and binary output (Reed relays): 1 current output frequency output: 1 and binary output (open collector): 1 current output: 1 and binary output (open collector): 1 current output I1, I2 - range 0/ ma ma - accuracy 0.1 % of reading ±15 μa % of reading ±15 μa - active output R ext < 500 Ω passive output U ext = V, depending on R ext R ext < 1 kω - U ext = V, depending on R ext R ext < 1 kω intrinsic safety current output I1 in HART mode - range ma passive output U ext = V - - frequency output range khz - open collector - 30 V/100 ma - I off = 0.8 ma optional: 8.2 V DIN N (NAMUR) binary output Reed relay 48 V/100 ma - - open collector 24 V/4 ma 30 V/100 ma I off = 0.8 ma 24 V/4 ma intrinsic safety binary output as alarm output - functions limit, change of flow direction or error open collector as pulse mainly for totalizing output - pulse value units - pulse width ms 3 connection of the interface RS232 outside of explosive atmosphere (housing cover open) TSFLUXUS_CYO_ V1-0N_Leu,

12 FLUXUS Cryo Dimensions FLUXUS F Ø thread: 4x M25 cable gland: max. 4x M20 in mm Wall and 2 " pipe mounting kit FLUXUS F TSFLUXUS_CYO_ V1-0N_Leu,

13 FLUXUS Cryo Terminal assignment FLUXUS F801**-A10****-*A FLUXUS F801**-A10****-*P! " # ) 8 ) 8 5 ) 4 5 ) 4 * 8 * 8 5 * 4 5 * 4! " # $ % & ' equipotential bonding terminal transducers outputs 2 - power supply power supply AC DC terminal connection terminal connection P earth P earth N neutral L- - L1 phase L+ + transducers measuring channel A measuring channel B terminal connection terminal connection AV transducer, signal BV transducer, signal AVS transducer, internal shield BVS transducer, internal shield ARS transducer, internal shield BRS transducer, internal shield AR transducer, signal BR transducer, signal cable gland external shield cable gland external shield outputs F801**-A10****-*A F801**-A10****-*P terminal connection terminal connection 1(-), 2(+) active current output I1 1(+), 2(-) passive current output I1 3(-), 4(+) active current output I2 (optional) 3(+), 4(-) passive current output I2 (optional) 5(-), 6(+) binary output B1 (open collector) 7(-), 8(+) binary output B2 (open collector, optional) 9(a), 10(b) binary output B1 (open collector, Reed relay, optional) 11(a), 12(b) binary output B2 (open collector, Reed relay, optional) 13(B-), 14(A+), communication interface 15 (shield) TSFLUXUS_CYO_ V1-0N_Leu,

14 FLUXUS Cryo FLUXUS F801C24 FLUXUS F801**-A10****-FF equipotential bonding terminal outputs partition (F801C24) transducers power supply power supply AC DC (F801**-A10****-FF) terminal connection terminal connection P earth P earth N neutral L- - L1 phase L+ + transducers measuring channel A measuring channel B terminal connection terminal connection AV transducer, signal BV transducer, signal AVS transducer, internal shield BVS transducer, internal shield ARS transducer, internal shield BRS transducer, internal shield AR transducer, signal BR transducer, signal S not connected S not connected cable gland external shield cable gland external shield outputs F801C24 F801**-A10****-FF colour of terminals blue (intrinsic safety) green terminal connection 1(-), 2(+) current output I1 frequency output F1 5(-), 6(+) binary output B1 (open collector) binary output B1 (open collector) 14 TSFLUXUS_CYO_ V1-0N_Leu,

15 FLUXUS Cryo Flow transmitter F809 Technical data FLUXUS F809**-A10 F809**-A1A design explosion proof field device 1 or 2 measuring channels zone 1 zone 1 (intrinsically safe current output) measurement measurement principle transit time difference correlation principle, automatic NoiseTrek selection for measurements with high gaseous or solid content flow velocity m/s repeatability 0.15 % of reading ±0.01 m/s fluid all acoustically conductive liquids with < 10 % gaseous or solid content in volume (transit time difference principle) temperature compensation corresponding to the recommendations in ANSI/ASM MFC accuracy 1 with standard calibration ±1.6 % of reading ±0.01 m/s with advanced calibration ±1.2 % of reading ±0.01 m/s (optional) with field calibration 2 ±0.5 % of reading ±0.01 m/s flow transmitter power supply V/ Hz or V DC V DC power consumption < 8 W number of flow measuring 1, optional: 2 channels damping s, adjustable measuring cycle (1 channel) Hz response time 1 s, option: 70 ms housing material cast aluminum, special offshore coating degree of protection according IP66 to IC/N dimensions see dimensional drawing weight 7.1 kg fixation wall mounting, 2 " pipe mounting operating temperature C (< -20 C without operation of the display) display 2 x 16 characters, dot matrix, backlight menu language nglish, German, French, Dutch, Spanish 1 for transit time difference principle, reference conditions and v > 0.15 m/s 2 reference uncertainty < 0.2 % TSFLUXUS_CYO_ V1-0N_Leu,

16 FLUXUS Cryo FLUXUS F809**-A10 F809**-A1A explosion protection zone 1 marking II2G II2G II2D II2D x db e IIC T6 Gb x tb IIIC T 100 C Db T a C A T X / I C x x db e ia IIC T6 Gb x tb ia IIIC T 100 C Db T a C certification ATX IBxU11ATX1022 X IBxU11ATX1022 X certification ICx ICx IB X ICx IB X type of protection gas: electronics compartment: flameproof enclosure, connection compartment: increased safety dust: protection by enclosure intrinsic safety parameters - measuring functions physical quantities totalizer calculation functions diagnostic functions data logger loggable values capacity communication interface serial data kit (optional) software (all Windows versions) gas: electronics compartment: flameproof enclosure, connection compartment: increased safety dust: protection by enclosure U m = 250 V U i = 30 V DC I i = 100 ma P i = 0.75 W C i = 3 nf volumetric flow rate, mass flow rate, flow velocity volume, mass average, difference, sum (2 measuring channels necessary) sound speed, signal amplitude, SNR, SCNR, standard deviation of amplitudes and transit times all physical quantities, totalized values and diagnostic values > measured values - process integration (optional): RS485 (sender) or Modbus RTU or HART - diagnosis: RS diagnosis: RS FluxData: download of measurement data, graphical presentation, conversion to other formats (e.g. for xcel ) - FluxDiag (optional): online diagnostics and report generation - FluxSubstanceLoader: upload of fluid data sets сable RS232 3 adapter RS232 - USB 3 3 connection of the interface RS232 outside of explosive atmosphere (housing cover open) 16 TSFLUXUS_CYO_ V1-0N_Leu,

17 FLUXUS Cryo FLUXUS F809**-A10 F809**-A1A outputs The outputs are galvanically isolated from the transmitter. number max. 4 1 current output number max. 2 - current output I1, I2 - - range 0/ ma - - accuracy 0.1 % of reading ±15 μa - - active output R ext < 500 Ω - - passive output U ext = V, depending on R ext, R ext < 1 kω - current output I1 in HART mode - range ma - - passive output U ext = V DC - - active output U int = 24 V - current output (intrinsic safety) number - 1 current output I1 - range ma - accuracy % of reading ±3 μa - passive output - U ext = V, depending on R ext, R ext < 1 kω current output I1 in HART mode - range ma - passive output - U ext = V DC frequency output number max. 1 - range khz - open collector 30 V/100 ma - or 8.2 V DIN N (NAMUR) or 24 V/4 ma (on request) binary output number max. 2 - Reed relay 48 V/100 ma - open collector 24 V/4 ma - optional: 30 V/100 ma or 8.2 V DIN N (NAMUR) binary output as alarm output - functions limit, change of flow direction or error - binary output as pulse output mainly for totalizing - pulse value units - - pulse width ms - TSFLUXUS_CYO_ V1-0N_Leu,

18 FLUXUS Cryo Dimensions FLUXUS F material: stainless steel 304 (1.4301) F809**-A1: thread, cable gland: 4x M20 x 1.5 F809**-A1: thread, cable gland: 2x M20 x 1.5 in mm Wall and 2 " pipe mounting kit 18 TSFLUXUS_CYO_ V1-0N_Leu,

19 FLUXUS Cryo Terminal assignment FLUXUS F809 equipotential bonding terminal upper housing, back view L N P (+) (-) outputs power supply transducers lower housing, front view AR ARS AVS AV BR BRS BVS BV equipotential bonding terminal (transducers) equipotential bonding terminal power supply AC DC terminal connection terminal connection L phase L+ + N neutral L- - P earth P earth transducers measuring channel A measuring channel B terminal connection terminal connection AV transducer, signal BV transducer, signal AVS transducer, internal shield BVS transducer, internal shield ARS transducer, internal shield BRS transducer, internal shield AR transducer, signal BR transducer, signal cable gland or equipotential bonding terminal (transducers) external shield cable gland or equipotential bonding terminal (transducers) external shield outputs terminal connection 1(-), 2(+) current output I1 frequency output F1 3(-), 4(+) current output I2 5(-), 6(+) binary output B1 (open collector) 7(-), 8(+) binary output B2 (open collector) 9(-), 10(+) binary output B1 (Reed relay) binary output B1 (open collector) A+, B-, S communication interface TSFLUXUS_CYO_ V1-0N_Leu,

20 FLUXUS Cryo Transducers Transducer selection for LNG, others on request outer pipe diameter mm, > 1000 mm on request transducer order code FSG FSK FSM FSP inner pipe diameter [mm] transducer order code FSG 11 FSK 5 FSM 2 FSP pipe wall thickness [mm] recommended possible Installation recommendation inner pipe diameter measurement arrangement number of sound paths min. number of measuring channels mm diagonal arrangement 3 1 > reflection arrangement 2 1 >180 diagonal arrangement TSFLUXUS_CYO_ V1-0N_Leu,

21 FLUXUS Cryo Technical data Shear wave transducers (zone 1) technical type CDG1N81 CDK1N81 CDM2N81 CDP2N81 order code FSG-NA1TS FSG-NA1TS/OS FSK-NA1TS FSK-NA1TS/OS FSM-NA1TS FSM-NA1TS/OS FSP-NA1TS FSP-NA1TS/OS transducer frequency MHz inner pipe diameter see Transducer selection pipe wall thickness min. mm material housing PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) contact surface PK PK PK PK degree of protection IP65 IP66 IP66 IP66 according to IC/ N transducer cable type length m dimensions length l mm width b mm height h mm dimensional drawing PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) h l l b b h h l l b b h weight (without cable) kg 0.47 kg 0.36 kg kg kg ambient temperature min. C max. C temperature compensation x x x x explosion protection category gas: 2G dust: 2D gas: 2G dust: 2D gas: 2G dust: 2D gas: 2G dust: 2D PL Gb Db Gb Db Gb Db Gb Db zone A T X / I C x explosion protection temperature (pipe surface) min. C max. C marking II2G II2G II2G II2G II2D II2D II2D II2D x e q IIC T6...T3 Gb x tb IIIC TX Db x e q IIC T6...T3 Gb x tb IIIC TX Db x e q IIC T6...T3 Gb x tb IIIC TX Db x e q IIC T6...T3 Gb x tb IIIC TX Db certification ATX IBxU07ATX1168 X IBxU07ATX1168 X IBxU07ATX1168 X IBxU07ATX1168 X certification ICx ICx IB X ICx IB X ICx IB X ICx IB X type of protection gas: increased safety, powder filling dust: protection by enclosure gas: increased safety, powder filling dust: protection by enclosure gas: increased safety, powder filling dust: protection by enclosure gas: increased safety, powder filling dust: protection by enclosure transducer mounting fixture necessary remark x x x x on request TSFLUXUS_CYO_ V1-0N_Leu,

22 FLUXUS Cryo Shear wave transducers (zone 2 or not explosion proof) technical type CDG1N52 CLG1N52 CDK1N52 CLK1N52 order code FSG-NA2TS FSG-NA2TS/OS FSG-NNNTS FSG-NNNTS/OS FSG-NA2TS/LC FSG-NA2TS/LC/OS FSG-NNNTS/LC FSG-NNNTS/LC/OS FSK-NA2TS FSK-NA2TS/OS FSK-NNNTS FSK-NNNTS/OS FSK-NA2TS/LC FSK-NA2TS/LC/OS FSK-NNNTS/LC FSK-NNNTS/LC/OS transducer frequency MHz inner pipe diameter see Transducer selection pipe wall thickness min. mm material housing PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) contact surface PK PK PK PK degree of protection IP67 IP67 IP67 IP67 according to IC/ N transducer cable type length m dimensions length l mm width b mm height h mm dimensional drawing PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) h l l b b h h l l b b h weight (without cable) kg 0.47 kg 0.47 kg 0.36 kg 0.36 kg ambient temperature min. C max. C temperature compensation x x x x explosion protection order code FSG-NA2TS FSG-NA2TS/LC FSK-NA2TS FSK-NA2TS/LC FSG-NA2TS/OS FSG-NA2TS/LC/OS FSK-NA2TS/OS FSK-NA2TS/LC/OS category gas: 3G dust: 2D gas: 3G dust: 2D gas: 3G dust: 2D gas: 3G dust: 2D PL Gc Db Gc Db Gc Db Gc Db zone A T X / I C x explosion protection temperature (pipe surface) min. C max. C gas: +190, dust: +180 gas: +190, dust: +180 gas: +190, dust: +180 gas: +190, dust: +180 marking II3G II3G II3G II3G II2D II2D II2D II2D x na IIC T6...T2 Gc x tb IIIC TX Db x na IIC T6...T2 Gc x tb IIIC TX Db x na IIC T6...T2 Gc x tb IIIC TX Db x na IIC T6...T2 Gc x tb IIIC TX Db certification ATX IBxU10ATX1163 X IBxU10ATX1163 X IBxU10ATX1163 X IBxU10ATX1163 X certification ICx ICx IB X ICx IB X ICx IB X ICx IB X type of protection gas: non sparking dust: protection by enclosure gas: non sparking dust: protection by enclosure gas: non sparking dust: protection by enclosure gas: non sparking dust: protection by enclosure transducer mounting fixture necessary x x x x 22 TSFLUXUS_CYO_ V1-0N_Leu,

23 FLUXUS Cryo Shear wave transducers (zone 2 or not explosion proof) technical type CDM2N52 CDP2N52 order code FSM-NA2TS FSM-NA2TS/OS FSM-NNNTS FSM-NNNTS/OS FSP-NA2TS FSP-NA2TS/OS FSP-NNNTS FSP-NNNTS/OS transducer frequency MHz 1 2 inner pipe diameter see Transducer selection pipe wall thickness min. mm 2 1 material housing PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) contact surface PK PK degree of protection IP67 IP67 according to IC/ N transducer cable type length m 4 4 dimensions length l mm width b mm height h mm dimensional drawing PK with stainless steel cap 304 (1.4301), option OS: 316L (1.4404) h l l b b h weight (without cable) kg kg kg ambient temperature min. C max. C temperature compensation x x explosion protection order code FSM-NA2TS FSP-NA2TS FSM-NA2TS/OS FSP-NA2TS/OS category gas: 3G dust: 2D gas: 3G dust: 2D PL Gc Db Gc Db zone A T X / I C x explosion protection temperature (pipe surface) min. C max. C gas: +190, dust: +180 gas: +190, dust: +180 marking II3G II3G II2D II2D x na IIC T6...T2 Gc x tb IIIC TX Db x na IIC T6...T2 Gc x tb IIIC TX Db certification ATX IBxU10ATX1163 X IBxU10ATX1163 X certification ICx ICx IB X ICx IB X type of protection gas: non sparking dust: protection by enclosure gas: non sparking dust: protection by enclosure transducer mounting fixture necessary x x TSFLUXUS_CYO_ V1-0N_Leu,

24 FLUXUS Cryo Transducer mounting fixture Order code no. of character description WaveInjector transducer measurement arrangement size fixation outer pipe diameter 1 coupling foil / WI-CYO type K shear wave transducers with transducer frequency G, K M shear wave transducers with transducer frequency M, P D reflection arrangement or diagonal arrangement L large C chains mm mm mm mm mm D coupling foil C A automatic WI tool M mechanical WI tool (pipe planer) O WIT-R tool 110 V R WIT-R tool 230 V N without tool B cryo insulation boxes for measuring channel (without transducer heating system) example WI-CYO M - D L - C D M / L WaveInjector Cryo for shear wave transducers with transducer frequency M, with chains, coupling foil and mechanical WI tool, transducer heating system (240 V) tool option 1 outer pipe diameter > 1000 mm on request WaveInjector WI-CYO l cp dimensions: h - length: 2. l + l cp l = 273 mm l cp = depending on application -width: outer pipe diameter + 32 mm (min. 203 mm) - height: outer pipe diameter + 2. h h = 285 mm material: stainless steel 304 (1.4301) l 24 TSFLUXUS_CYO_ V1-0N_Leu,

25 FLUXUS Cryo Coupling materials for transducers Technical data type ambient temperature material position C coupling foil type SI silicone coupling plate - transducer coupling foil type D indium pipe - coupling plate TSFLUXUS_CYO_ V1-0N_Leu,

26 FLUXUS Cryo Connection systems connection system TS connection with extension cable JB01 direct connection transducers technical type *****8* x l transmitter transmitter x JB02, JB03 x x *****52 l transmitter transmitter T S transducer frequency (3d character of transducer order code) F, G, H, K M, P Q S x l x l x l x l cable length m cable length (option LC) m x - transducer cable length l - max. length of extension cable Transducer cable Technical data transducer cable extension cable type ambient temperature C properties halogen free halogen free fire propagation test according to IC combustion test according to IC fire propagation test according to IC combustion test according to IC cable jacket material PTF PUR PUR outer diameter mm thickness mm colour brown black black shield x x x sheath material stainless steel 304 (1.4301) - steel wire braid with copolymer option OS: 316Ti (1.4571) sheath outer diameter mm TSFLUXUS_CYO_ V1-0N_Leu,

27 FLUXUS Cryo Junction box Technical data technical type JB01S43M JB02 JB03 dimensions see dimensional drawing see dimensional drawing see dimensional drawing weight kg 1.2 kg 1.2 kg 1.2 kg fixation Dimensions wall mounting, optional: 2 " pipe mounting wall mounting, optional: 2 " pipe mounting wall mounting, optional: 2 " pipe mounting material housing stainless steel 316L (1.4404) stainless steel 316L (1.4404) stainless steel 316L (1.4404) gasket silicone silicone silicone degree of protection IP67 IP67 IP67 according to IC/ N ambient temperature min. C max. C explosion protection zone A T X / I C x marking II2G II2D x e mb IIC (T6)...T4 Gb x tb IIIC T 100 C Db Ta (70)80 C II3G x na IIC (T6)...T4 Gc II3D x tc IIIC T 100 C Dc Ta (70)80 C certification ATX IBxU06ATX certification ICx ICx IB type of protection gas: increased safety decoupled network: encapsulation dust: protection by enclosure gas: non sparking dust: protection by enclosure - - wall mounting holder Ø thread: 3x M20 x 1.5 cable gland: max. 2x M20 in mm TSFLUXUS_CYO_ V1-0N_Leu,

28 8 4 FLUXUS Cryo 2 " pipe mounting kit (optional) Terminal assignment JB / 6 / shield terminal equipotential bonding terminal (at wall mounting holder) transducers terminal strip KL1 terminal connection V transducer, signal VS transducer, internal shield RS transducer, internal shield R transducer, signal cable gland external shield extension cable terminal strip KL2 terminal TV TVS TRS TR shield terminal connection signal internal shield internal shield signal external shield JB02, JB / 6 / transducers terminal connection XV transducer, SMB connector XR transducer, SMB connector cable gland external shield shield terminal : 8 : 4 extension cable terminal strip KL2 terminal TV TVS TRS TR shield terminal connection signal internal shield internal shield signal external shield equipotential bonding terminal (at wall mounting holder) 28 TSFLUXUS_CYO_ V1-0N_Leu,

29 FLUXUS Cryo Transducer heating system (optional) Continous operation fluid temperature < -40 C: transducer heating system required Cycle operation operating time in cycle operation > 12 h: transducer heating system required operating time in cycle operation < 12 h and rest period 2x operating time: see table below fluid ambient temperature temperature C C x x x x x x -190 x x x x x x -180 x x x x x -170 x x x x x -160 x x x x -150 x x x x -140 x x x x -130 x x x -120 x x x -110 x x -100 x x -90 x x -80 x -70 x x - transducer heating system required Technical data type BARTC PSB order code ACC-P-Fxxx-CY1 (1 measuring channel) ACC-P-Fxxx-CY2 (2 measuring channels) ACC-P-Fxxx-CY3 (1 measuring channel) ACC-P-Fxxx-CY4 (2 measuring channels) power supply 240 V AC 120 V AC consisting of - heating element PSB 33, PSB 33, connection system PLXO TCS P PLXO TCS P junction box PSB / /2090 explosion protection ATX, ICx, TR TS Cable junction box PSB - heating element type H05SS-F length m 10 max. length m on request weight kg/m 0.11 ambient temperature C installation C temperature bend radius 7.5 D properties cable jacket material rubber outer diameter D mm colour black shield - TSFLUXUS_CYO_ V1-0N_Leu,

30 FLUXUS Cryo Insulation h i h insulation height: h i = max. 185 mm height h: - with transducer heating system: h < 30 mm - without transducer heating system: h 100 mm 30 TSFLUXUS_CYO_ V1-0N_Leu,

31 FLUXUS Cryo FLXIM GmbH Wolfener Str. 36 internet: Berlin 117 Germany Tel.: +49 (30) Fax: +49 (30) Subject to change without notification. rrors excepted. FLUXUS is a registered trademark of FLXIM GmbH. TSFLUXUS_CYO_ V1-0N_Leu,

Technical specification FLUXUS WD

Technical specification FLUXUS WD Technical specification FLUXUS WD Non-invasive ultrasonic flow measurement on buried pipes Permanently installed clamp-on ultrasonic flow measurement system for buried water and wastewater pipes Features

More information

Technical specification PIOX S721SA

Technical specification PIOX S721SA Ultrasonic measurement of sulfuric acid Non-invasive clamp-on ultrasonic measuring system for continuous monitoring of concentration, density or other process-relevant fluid properties Features Bidirectional

More information

Technical specification PIOX S721SA. Ultrasonic measurement of sulfuric acid. Features. Applications

Technical specification PIOX S721SA. Ultrasonic measurement of sulfuric acid. Features. Applications Technical specification Ultrasonic measurement of sulfuric acid Non-invasive clamp-on ultrasonic measuring system for continuous monitoring of concentration, density or other processrelevant fluid properties

More information

Technical Specification FLUXUS ADM 8x27

Technical Specification FLUXUS ADM 8x27 Ultrasonic Flow Measurement of Liquids in Explosive Atmosphere Features Transducers non-invasive (no contact with the medium, no need for expensive materials) wearfree no pressure drop (no operational

More information

Technical Specification FLUXUS ADM 8127B

Technical Specification FLUXUS ADM 8127B FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere

More information

Technical specification FLUXUS F401 H2O

Technical specification FLUXUS F401 H2O Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy

More information

Technical specification FLUXUS F704TE

Technical specification FLUXUS F704TE Technical specification Permanently installed and non-invasive ultrasonic flowmeter for the measurement of thermal energy and volumetric flow rate Precise and intelligent energy measuring system with extremely

More information

Technical specification FLUXUS F601

Technical specification FLUXUS F601 FLUXUS F601 Portable ultrasonic flow measurement of liquids Portable instrument for non-invasive, quick ultrasonic flow measurement with clamp-on technology for all types of piping Features Precise bi-directional

More information

Technical Specification FLUXUS F601

Technical Specification FLUXUS F601 FLUXUS F601 Portable Ultrasonic Flow Measurement of Liquids Portable instrument for non-intrusive, quick ultrasonic flow measurement with clamp-on technology for all types of piping Features Precise bi-directional

More information

Technical specification PIOX R400-*CTF

Technical specification PIOX R400-*CTF Technical specification Transmitted light process refractometer for Highly Corrosive Process Conditions For a wide range of applications in the field of chemistry Sensor Properties inline process refractometer

More information

Technical Specification FLUXUS F601

Technical Specification FLUXUS F601 FLUXUS F601 Portable Ultrasonic Flow Measurement of Liquids Portable instrument for non-invasive, quick ultrasonic flow measurement with clamp-on technology Features Non-invasive measurement using the

More information

Technical specification PIOX R400-*H

Technical specification PIOX R400-*H Technical specification PIOX R400-*H Transmitted light process refractometer For a wide range of applications in the field of hygiene Sensor Properties unique transmitted light process refractometer one

More information

Technical Specification FLUXUS F608**-F2

Technical Specification FLUXUS F608**-F2 Portable Ultrasonic Flow Measurement of Liquids in Hazardous Areas Portable instrument for non-intrusive, quick ultrasonic flow measurement with clamp-on technology for all types of piping Features Precise

More information

Technical Specification FLUXUS G601

Technical Specification FLUXUS G601 Portable Ultrasonic Flow Measurement of Gas New portable instrument for non-invasive, quick ultrasonic flow measurement with clamp-on technology for all types of piping Features Non-invasive measurement

More information

Technical Specification FLUXUS F601

Technical Specification FLUXUS F601 FLUXUS F601 Portable Ultrasonic Flow Measurement of Liquids Portable instrument for non-intrusive, quick ultrasonic flow measurement wit clamp-on tecnology for all types of piping Features Precise bi-directional

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Technical Specification PIOX R400-*C

Technical Specification PIOX R400-*C Technical Specification PIOX R400-*C Transmitted Light Process Refractometer For a wide range of applications in the field of chemistry Sensor Properties unique transmitted light process refractometer

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

User Manual UMFLUXUS_G7V4-0-2EN. Ultrasonic Flowmeter for Gas FLUXUS G704 FLUXUS G704 A2 FLUXUS G709. Firmware V5.xx

User Manual UMFLUXUS_G7V4-0-2EN. Ultrasonic Flowmeter for Gas FLUXUS G704 FLUXUS G704 A2 FLUXUS G709. Firmware V5.xx User Manual UMFLUXUS_G7V4-0-2EN Ultrasonic Flowmeter for Gas FLUXUS G704 FLUXUS G704 A2 FLUXUS G709 Firmware V5.xx MS-DOS, Excel, Windows are registered trademarks of Microsoft Corporation. FLUXUS is a

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009 VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter Portable flowmeter with two measurement channels, optional process outputs and Heat Quantity Measurement capability For commonly used pipe materials and diameters from 10 mm to over 3.0 m Intuitive menu,

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

Head mounted Temperature Transmitter TF02/TF02-Ex

Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance

More information

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016 Advancements in Clamp-on Ultrasonic Flow Measurements 2016 Biosolids Workshop December 1 st 2016 Market Leader in Clamp-On Ultrasonic Flowmeters with >50,000 instruments sold Background Information Extraordinary

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S. EN SolidFlow.0 Product Information Solid mass flow measurement SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.A Group Use SolidFlow.0 has been specially developed for measuring

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Weighing Instruments

Weighing Instruments GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation

More information

General Specifications

General Specifications General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

LST100 Ultrasonic level transmitter for upstream oil and gas

LST100 Ultrasonic level transmitter for upstream oil and gas Data sheet DS/LST100-EN LST100 Ultrasonic level transmitter for upstream oil and gas Accurately track and measure the most expensive consumable on your site chemicals. Measurement made easy Features Keep

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Ultrasonic level meters ULM 70

Ultrasonic level meters ULM 70 průmyslová elektronika Ultrasonic level meters ULM 70 For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels, drains, etc.

More information

OPTIWAVE 7300 C Supplementary instructions

OPTIWAVE 7300 C Supplementary instructions OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Page Type Resolution (mm) min. max. Output

Page Type Resolution (mm) min. max. Output Data Sheet Overview -1- Page Type Resolution (mm) min. max. Output Ind. lenght Ind. lenght 2 XM/XT-800E 5 +/- 2 400 mm 3000 mm current/voltage 6 XM/XT-825E 2.5 +/- 1 200 mm 1500 mm current/voltage 10 XM/XT-800E-PVDF

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - # Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

MaxxFlow HTC Flow measurement for dry bulk solids

MaxxFlow HTC Flow measurement for dry bulk solids Product Information EN MaxxFlow HTC Flow measurement for dry bulk solids SWR engineering Messtechnik GmbH envea TM a trademark of Environnement S.A Group MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Use The

More information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,

More information

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

C4000. inline control. Photometric Converter.  Real-time photometric converter. Factory zero for scattered light sensors C4000 Photometric Converter inline control Real-time photometric converter Factory zero for scattered light sensors Simultaneous operation of up to four inline sensors Process control functions via Remote

More information

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data Technical documentation Table of content Page 2: Page 3: Page 4: Page 5: Page 6: Page 7: Page 8: Characteristics - applications - technical data Technical data - input quantity - output quantity Electrical

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

OPTIWAVE 1010 Technical Datasheet

OPTIWAVE 1010 Technical Datasheet OPTIWAVE 1010 Technical Datasheet Radar (FMCW) Level Transmitter for bypass chambers and magnetic level indicators (BM 26 Advanced) Device welded to a bypass chamber with an optional IP68 level indicator

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high

More information

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C Coriolis Massflowmeter for liquids and gases measuring monitoring analysing TME OMeasuring O range: 0-60 kg/h 0-60000 kg/h water O O Accuracy: ±0.15 of reading ± zero-point stability OO p max : PN40 t

More information

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transducer transmitter BILT 4 II 2(1) G. Technical Manual GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical

More information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building

More information

CALYS 100. Field precision documenting multifunction calibrator

CALYS 100. Field precision documenting multifunction calibrator Field precision documenting multifunction calibrator is a precision documenting multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

Load cell. Special features. Data sheet

Load cell. Special features. Data sheet Z6R Load cell Special features - Nominal (rated) loads: 20 kg 200 kg - Welded-on robust cover - Load cells made of rust-resistant materials - Easy to clean - Same dimensions like Z6F - Verifiable up to

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

Differential charge amplifier

Differential charge amplifier Electronics Differential charge amplifier Type 5181A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure

More information

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 807-0 Fax: 0640 807-259 IT system floor-standing distribution cabinet Series -IPS-F/EDS for supplying power to medical locations

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Technical specification FLUXUS F705. Liquid ultrasonic flowmeter for permanent installation. Features. Applications

Technical specification FLUXUS F705. Liquid ultrasonic flowmeter for permanent installation. Features. Applications Tecnica specification FLUXUS F70x Liquid utrasonic fowmeter for permanent instaation Transmitter for permanent outdoor wa or pipe mounting Features Precise i-directiona and igy dynamic fow measurement

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard

More information

Ult r a s o n i c le v e l me t e r s ULM 55

Ult r a s o n i c le v e l me t e r s ULM 55 Ult r a s o n i c le v e l me t e r s ULM 55 For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels etc. Xi version for

More information