VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Size: px
Start display at page:

Download "VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009"

Transcription

1 VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement can be done anywhere and startup is immediate. The new VERSAFLOW clamp on flowmeter for liquids with its robust industrial construction and regreasing concept provides a revolutionary solution for easy handling Figure 1 VersaFlow Ultrasonic clamp-on Flowmeter Highlights Applications Minimised uncertainty Optimised reliability Minimal maintenance Efficient regreasing concept Easy sensor mounting Installation wizard All in one system Industries Chemical addition General process control Cooling water circuits Broad range of refined hydrocarbons Potable water De-ionized and demineralized water Sanitary flow rate measurements Purified water Chemicals Petrochemical Power Plants Water Oil & Gas Semi-conductor Food & Beverage Pharmaceuticals

2 Page 3 Technical Data Ultrasonic flowmeter VERSAFLOW Versions VERSAFLOW VERSAFLOW - Ex, zone 1/2 Performance Measurement functionality Measuring range Max. deviation (under reference conditions] actual volume flow rate and totalised volume m/s / ft/s <± 1% of M.V. for DN ~ 50 mm / 2", v > 0.5 m/s / 1.5 ft/s <± 3% of M.V. for DN < 50 mm / 2", v > 0.5 m/s / 1.5 ft/s Repeatability <± 0.2% Process conditions Solid particle content < 5% (by volume) Gas content < 2% (by volume) Measurement configurations Single path, single pipe or dual path/dual pipe Ultrasonic flow sensor VERSAFLOW Versions VERSAFLOW - small (DN15...DN100 / ½...4") VERSAFLOW - medium (DN50...DN400 / ) VERSAFLOW - large (DN200...DN4000 / ) VERSAFLOW - small (ext. temp. DN15...DN100 / ½...4 ) VERSAFLOW - medium (ext. temp. DN50...DN400 / ) Pipe specifications Material: metal, plastic, ceramic, asbestos cement, internal/external coated pipes (coatings and liners fully bonded to pipe wall) Maximum pipewall thickness of 200 mm / 7.87" Protection category IP67 Electric signal level Ex-I, intrinsically safe circuits, floating Process temperature C / F C / F, XT version

3 Page 4 Sensor cable length 5 m / 15 t 10 m / 30ft 20 m / 0ft 30 m / 90ft Recommended mounting areas Inlet Outlet ~ 10DN ~ 5DN Ultrasonic flow converter TWS9000 Versions W (wall) F (field) F(/i-)Eex, zone 1/2 Display languages With Local display English, French, German TWS9000 W (general purpose) TWS9000 F (non-ex) TWS9000 F-Ex Flow Sensor VERSAFLOW DN / ½ Communication Current, pulse & status output HART communication, control input Power Supply VAC (-15/+10%), 50/60 Hz 24 VAC/DC Power consumption 22 VA Approvals EEx - zone 1, zone 2 FM - Class I DIV 1, DIV 2 CSA - / Class I DIV 1, DIV 2 Protection category W (wall) F (field) IP65 (eq. to NEMA 4/4X) IP66/67 (eq. to NEMA6) Temperature Process see flow sensor Ambient C / F Storage C / F Cable connection M20 x 1.5 ½ NPT PF ½ 1 Outer Diameter: mm /

4 Page 5 Materials used Polyamide - polycarbonate (W-version) Die-cast aluminium with polyurethane coating) (F-version) Stainless steel 316 L / (F-version) Overall functionality Highlights Continuous measurement of actual volume flow rate, flow velocity, velocity of sound, damping of acoustic signal, signal to noise ratio Flow direction (forward or reverse) Totalisation of volume flow Reliability of flow measurement, Quality of acoustic signal Current Output Q = 0% Q = 100% Error identification Connection Active: Basic/Modular IO Connection Passive: Basic/Modular IO All operating data configurable; galvanically isolated; HART communication ma ma ma I 22 ma / R L 1 kohm I 22 ma / R L 470 Ù U O = 21V / l O = 90 ma P O = 0.5 W C O = 90 nf / L O = 2 mh L 22mA / U 32 VDC I 22 ma U i = 30 V / l i = 100 ma P i = 1 W C i = 10 nf / L i ~ 0 mh

5 Page 6 Pulse output and status output Configurable as pulse output, identification for automatic range change, indicator of flow direction, overflow, errors, trip point or empty pipe indication Q = 100% Pulse width Status Connection Active: Connection Passive: Valve control, if batch control function is activated pulses/s or pulses/volume ms or auto or sym. On or Off f 10 khz: I 20 ma f 10 Hz: I 100 ma U 32 VDC / I 100 ma Acc. EN U i = 30V / I i = 100 ma P i = 1 W Connection NAMUR: Control input C i = 10 nf/l i ~ 0 mh "Active" Freeze output (e.g. during cleaning), forced return to zero, counter and error reset, ext. range selection. Freeze outputs, output zero, reset counter, reset error Connection Active: l nom 16mA / U nom 24VDC Acc. EN Connection Passive: Connection NAMUR: U d 32 VDC U on ~ 19 VDC / U off < 2.5 VDC "Active"

6 Page 7 I/O Specifications Overall functionality Current output Connection Basic / Modular IO: Active Ex-i: Active Basic/ Modular IO: Passive Ex-i: Passive Pulse output and Status output Connection Basic/ Modular IO: Passive Passive Active Namur (ace. to EN ) Control input Connection Basic / Modular IO: Active Basic/ Modular IO: Passive Namur (ace. to EN ) Continuous measurement of actual volume flow, mass flow, flow speed velocity of sound gain SNR diagnosis value. Bidirectional flow measurement and totalisation. Signal quality bar graph All operating data configurable; galvanically isolated; HART communication Q = 0%:0...15mA Q = 100%: mA Error identification: mA l 22mA / R L 1 kohm l 22mA / R L 470 Ohm U O = 21 V/l 0 = 90mA P O = 0.5W C O = 90nF / L0 = 2mH l 22mA / U 32VDC I 22mA U i = 30V / l i = 100mA P i = 1W C i = 10nF / L i ~ 0mH Configurable as pulse output, identification for automatic range change, indicator of flow direction, overflow, errors, trip point or empty pipe indication Q = 100%: pulses per second or pulses per unit volume Pulse width: ms or auto or sym. Status: On or Off f 10kHz: I 20mA f 10Hz: I 100mA U 32 VDC / l 100mA U i = 30V / l i = 100mA P i = 1W C i = 10nF / L i i ~ 0mH U nom = 24VDC / l <1 ma U O = 1.5 V at 10mA Passive Freeze output (e.g. during cleaning), forced return to zero, counter and error reset, ext. range selection. Freeze outputs, output zero, reset counter, reset error, start batch (in batch mode) l nom = 16mA / U nom = 24VDC U 32VDC U on > 19VDC / U off < 2.5VDC Active

7 Page 11 Dimensions and weights Dimensions [mm] Approx. weight Version (without cable / strip) L H W [kg] small medium large Version Dimensions [inches] Approx. weight (without cable / strip) L H W [lbs] small medium large Value for one of the 2 delivered rails

OPTISONIC 6300 Technical Datasheet

OPTISONIC 6300 Technical Datasheet OPTISONIC 6300 Technical Datasheet Ultrasonic clamp-on flowmeter Robust industrial clamp-on construction Immediate start-up All in one concept KROHNE CONTENTS OPTISONIC 6300 1 Product features 3 1.1 Clamp-on

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

OPTISONIC 7300 Technical Datasheet

OPTISONIC 7300 Technical Datasheet OPTISONIC 7300 Technical Datasheet Ultrasonic gas flowmeter Wide application range No moving parts and no pressure loss Complete solution for gasflow measurement KROHNE CONTENTS OPTISONIC 7300 1 Product

More information

OPTISONIC 6300 P Technical Datasheet

OPTISONIC 6300 P Technical Datasheet OPTISONIC 6300 P Technical Datasheet Portable ultrasonic clamp-on flowmeter User friendly operation through full colour graphic display and full keypad Quick and easy transfer of logged data to your PC

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

OPTISONIC 7300 Technical Datasheet

OPTISONIC 7300 Technical Datasheet OPTISONIC 7300 Technical Datasheet Ultrasonic gas flowmeter Wide application range No moving parts and no pressure loss Complete solution for gasflow measurement KROHNE CONTENTS OPTISONIC 7300 1 Product

More information

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications 34-VF-03-04 September 2011 The High-Performance Solution The TWC 9000 is a universal coriolis meter converter suitable for a wide

More information

OPTIFLUX 1000 Technical Datasheet

OPTIFLUX 1000 Technical Datasheet OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when

More information

OPTISONIC 6300 Quick Start

OPTISONIC 6300 Quick Start OPTISONIC 6300 Quick Start Ultrasonic clamp-on flowmeter ER 3.4.0_ KROHNE CONTENTS OPTISONIC 6300 1 Installation 4 1.1 Intended use... 4 1.2 Scope of delivery... 4 1.3 Overview... 5 1.4 Storage... 5 1.5

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

IFC 010 Signal Converter

IFC 010 Signal Converter KROHNE 04/2003 7.02347.22.00 GR Signal Converter for electromagnetic flowmeters Easy to install Low-cost signal converter, measuring error < 0.5% of the measured value Easy user-friendly operation Self-monitoring

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

WATERFLUX 3070 Technical Datasheet

WATERFLUX 3070 Technical Datasheet WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

OPTISONIC 3400 Technical Datasheet

OPTISONIC 3400 Technical Datasheet OPTISONIC 3400 Technical Datasheet Measurement of (non- ) conductive, low and high viscous liquids, from -200 C to +250 C media temperature Accurate bi-directional measurement that starts from zero flow

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature

More information

IFC 050 Technical Datasheet

IFC 050 Technical Datasheet IFC 050 Technical Datasheet Signal converter for electromagnetic flowmeters For water and wastewater applications Multiple outputs, incl. active pulse output and RS485 Modbus Excellent price/performance

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

IFC 100 Technical Datasheet

IFC 100 Technical Datasheet IFC 100 Technical Datasheet Signal converter for electromagnetic flowmeters Simple and easy to install and start-up Diagnostics of device and application Extremely fast signal conversion The documentation

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

OPTIMASS 1000 Technical Datasheet

OPTIMASS 1000 Technical Datasheet OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

IFC 050 Technical Datasheet

IFC 050 Technical Datasheet IFC 050 Technical Datasheet Signal converter for electromagnetic flowmeters For simple applications Multiple outputs, incl. active pulse output and RS485 Modbus Excellent price/performance ratio The documentation

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm) KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

MFC 400 Technical Datasheet

MFC 400 Technical Datasheet MFC 400 Technical Datasheet Signal converter for mass flowmeters High performance signal converter for all applications Stable in multi-phase applications due to synthesised drive High developed diagnostic

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

BATCHFLUX and BATCHCONTROL

BATCHFLUX and BATCHCONTROL KROHNE 04/2001 D 31 BATC 02 E GR/PRINTO BATCHFLUX and volumetric batching and dosing with electromagnetic flowmeters A new era in volumetric batching!!! Optimum sanitary design Ceramic measuring tube Only

More information

IFC 100 Technical Datasheet

IFC 100 Technical Datasheet IFC 100 Technical Datasheet Signal converter for electromagnetic flowmeters Simple and easy to install and start-up Diagnostics of device and application Extremely fast signal conversion The documentation

More information

IFC 300 Technical Datasheet

IFC 300 Technical Datasheet IFC 300 Technical Datasheet Signal converter for electromagnetic flowmeters Diagnostics: Process and device diagnostics, accuracy check One signal converter for all applications Exceeds requirements of

More information

MFC 400 Technical Datasheet

MFC 400 Technical Datasheet MFC 400 Technical Datasheet Signal converter for mass flowmeters High performance signal converter for all applications Stable in multi-phase applications due to Entrained Gas Management (EGM ) High developed

More information

IFC 300 Technical Datasheet

IFC 300 Technical Datasheet IFC 300 Technical Datasheet Signal converter for electromagnetic flowmeters All-round signal converter matches almost any application requirement Reliable measurements with extensive diagnostics of device

More information

OPTISONIC 4400 Technical Datasheet

OPTISONIC 4400 Technical Datasheet OPTISONIC 4400 Technical Datasheet Ultrasonic liquid flowmeter for high temperature and high pressure Accurate and repeatable measurement; long lasting and robust industrial design Efficient foil wave

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

IFC 050 Technical Datasheet

IFC 050 Technical Datasheet IFC 050 Technical Datasheet Signal converter for electromagnetic flowmeters For simple applications Multiple outputs, incl. active pulse output and RS485 Modbus Excellent price/performance ratio The documentation

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved. Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the

More information

Technical specification FLUXUS F401 H2O

Technical specification FLUXUS F401 H2O Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

MFC 400 Technical Datasheet

MFC 400 Technical Datasheet MFC 400 Technical Datasheet Signal converter for mass flowmeters High performance signal converter for all applications, developed acc. to IEC 61508, SIL 2/3 Stable in multi-phase applications due to Entrained

More information

FLOWMETER. Siemens MAG 5000/6000. Overview

FLOWMETER. Siemens MAG 5000/6000. Overview Overview Design The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP65/NEMA

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

MFC 300 Technical Datasheet

MFC 300 Technical Datasheet MFC 300 Technical Datasheet Signal converter for mass flowmeters Modular signal converter concept and the same hardware for all housing designs Double redundancy of the calibration data Stainless steel

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Overview SITS FUH1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for applications carrying crude oil, refined petroleum or liquefied gas. SITS FUH1010 has three application areas: Interface detectors,

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P

Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P Technical Information TI 056D/24/ae Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P Volume flow measurement of liquids in chemical or process applications Features and benefits

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

2-Wire. Level Gauge BM 702

2-Wire. Level Gauge BM 702 KROHNE 09/2001 7.02323.22.00 GR/PRINTO Level Gauge 2-Wire Level-Radar 2-Wire The first and only FMCW Radar Level Gauge with 2-wire technology The non-contact alternative to ageing technologies Maintenance-free

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Mass Flowmeter CoriolisMaster FCM2000

Mass Flowmeter CoriolisMaster FCM2000 Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Echotel Trident 91S/92S Ultrasonic Level Switches

Echotel Trident 91S/92S Ultrasonic Level Switches Echotel Trident 91S/92S Ultrasonic Level Switches D E S C R I P T I O N The Trident 91S/92S detects single or dual point level in a wide variety of liquid applications. It is available with either an ma

More information

MFC 400 Technical Datasheet

MFC 400 Technical Datasheet MFC 400 Technical Datasheet Signal converter for mass flowmeters High performance signal converter for all applications, developed acc. to IEC 61508, SIL 2/3 Stable in multi-phase applications due to Entrained

More information

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max

More information

IFC 100 / IFC 300. Electromagnetic flow converters for the OPTIFLUX series

IFC 100 / IFC 300. Electromagnetic flow converters for the OPTIFLUX series IFC 100 / IFC 300 Electromagnetic flow converters for the OPTIFLUX series 4 The most innovative converter line 4 IFC 100 for all standard applications 4 IFC 300 the high-end device even for difficult applications

More information

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter Portable flowmeter with two measurement channels, optional process outputs and Heat Quantity Measurement capability For commonly used pipe materials and diameters from 10 mm to over 3.0 m Intuitive menu,

More information

Technical Specification FLUXUS ADM 8127B

Technical Specification FLUXUS ADM 8127B FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

JUMO flowtrans MAG S01

JUMO flowtrans MAG S01 Phone: +49 661 6003-0 Fax: +49 661 6003-607 Internet: www.jumo.net Fax: +44 1279 635262 sales@jumo.co.uk Fax: 315-437-5860 info.us@jumo.net Page 1/57 JUMO flowtrans MAG S01 Electromagnetic flowmeter for

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview Benefits Process Intelligence for advanced signal processing and quick and easy adjustment Self-guided quick start wizard for plug and play startup 2 GHz provides superior reflective properties

More information

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI Overview The is a -wire, 2 GHz FMCW radar level transmitter with extremely high signal-to-noise ratio and advanced signal processing for continuous monitoring of solids up to 100 m (328 ft). It is ideal

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

LST400 Ultrasonic level / open channel flow transmitter

LST400 Ultrasonic level / open channel flow transmitter Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

Applications Features

Applications Features GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

Rod probe With coaxial tube reference probe

Rod probe With coaxial tube reference probe Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions

More information

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance

More information

OPTIFLUX 2000 Technical Datasheet

OPTIFLUX 2000 Technical Datasheet OPTIFLUX 2000 Technical Datasheet Electromagnetic flow sensor For all water and wastewater applications Wide range of approvals for potable water Robust, fully welded construction The documentation is

More information

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as

More information

Electromagnetic Flow Measuring System promag 35

Electromagnetic Flow Measuring System promag 35 Technical Information TI 035D/06/en No. 50075884 Electromagnetic Flow Measuring System promag 35 Applications Promag 35 S solves complex flow problems and is used to measure fluids with a high solids content,

More information