UFM 800 W, C Ultrasonic flowmeter for water and wastewater
|
|
- Delilah Atkinson
- 5 years ago
- Views:
Transcription
1 KROHNE 08/ GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring instruments Communications engineering Engineering systems & solutions
2 , C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Efficient flow measurement and volume counting of all types of water and wastewater in closed pipelines or in open channels and raceways. Advantages No constriction of the pipe cross-section No additional pressure drop Electrical conductivity, pressure, density, etc. have no effect on measurements Easy to install from the outside or the inside No maintenance requirement Low power consumption Low operating costs Ultrasonic flowmeters with UFS 800 W sensors for measuring the volumetric flowrate in metal pipelines. The sensors are welded to the outside of the pipelines. Ultrasonic flowmeter with UFS 800 C sensors for measuring flow velocity in open channels. The sensors can be installed or mounted from the inside or outside of the channel. UFC 500 F signal converter Digital signal processing Easy to operate Current, pulse and status outputs Low power consumption Large clear text LC display, easy to read 2
3 Calibration Installation notes UFM 800 Systems Versions Sensors Single-beam measurement Double-beam measurement Signal converter Hazardous-duty version Application/Measurement Accuracies Measurement Linearity Repeatability for measuring process liquids in metal pipelines DN / x UFS 800 W 4 x UFS 800 W (option) UFC 500 pending Volumetric flowrate Volume counts Direction of flow Transit time measurement typical values, dependent upon application ± 3% of measured value ± 0.5% of measured value (v > 0.5 m/s or > 1.6 ft/s) ± 0.2% of measured value for measuring process liquids in open channels Width: mm 2 x UFS 800 C UFC 500 / M 4.1 Flow velocity Direction of flow typical values, dependent upon application ± 5% of measured value ± 0.5% of measured value ± 0.2% of measured value Background Flowtubes UFM 500 Clamp-on UFM 600/610 Weld-om Open channel Dimensions and weights Dimensions in mm and (inch) Gasflowtube GFM 700 UFC 500 F signal converters Weight: approx. 4.2 kg (9.3 lb) Ø 122 (4.80 ) 208 (8.19 ) Custody transfer ALTOSONIC V UFS 800 W sensors UFS 800 C sensors Sizing guide Ordering guide / 3
4 UFM 800 Responsibility for suitability and intended use of our instruments rests solely with the purchaser. Technical data Sensors UFS 800 W UFS 800 C Versions Single-beam measurement Double-beam measurement Hazardous-duty version to European Standard Application data Mounting location Sensor alignment Operating data Process temperature Pressure Ambient temperature Storage temperature (electronics) (electronics) Protection category (IEC529/EN 60529) Standard Optional Material Sensor Sensor mount 2 x FS 500 W 4 x FS 500 W (option) replaceable at operating pressure Ex de ib, pending on metal pipelines meter size DN / DN 1000 / 40 acoustic alignment (water only) DN > 1000 / > 40 by KROHNE technicians using laser alignment set 50 to +170 C / 58 to +338 F max. 40 bar / max. 580 psig 25 to +60 C / 13 to +140 F 40 to +60 C / 40 to +140 F (IEC529/EN 60529) IP 65 equivalent to NEMA 12 and 13 IP 67, IP 68 equivalent to NEMA 6 stainless steel equivalent to SS 316 L stainless steel equivalent to SS 304 others on request 2 x FS 500 C Installation in open channels, Mounted from the outside or the inside Width: mm / by KROHNE technicians with laser alignment set 25 to +120 C / 13 to +248 F max. 10 bar / max. 150 psig 25 to +60 C / 13 to +140 F 40 to +60 C / 40 to +140 F IP 65 equivalent to NEMA 12 and 13 IP 67, IP 68 equivalent to NEMA 6 stainless steel or SS 304, Pyrex and Viton stainless steel or SS 304 and Viton others on request 4 /
5 UFM 800 UFC 500 F Signal converters Versions Standard Option Hazardous- duty version Full-scale range Volumetric flowrate Q 100% Setting range m 3 /hr US gal/min Units any Current output Function UFC 500 F UFC 500 F / MP, settable via magnetic sensors and bar magnet UFC 500 F-EEx continuous flowrate measurement or measurement of sound velocity to determine (composition of) liquid product all operating data configuration galvanically isolated for active and passive mode useable as internal power supply for the binary outputs Current for Q = 0%: 0 16 ma for Q = 100%: 4 20 ma } settings in 1 ma increments (I max = 22 ma) Active mode load max. 680 Ohm Passive mode external voltage: 18 V DC Low-flow cutoff load 680 Ω cutoff on value: 1 19% cutoff off value: 2 20% } of Q 100%, setting in 1% increments Time constant s, setting in increments of 1, 0.1 or 0.01 s Forward / reverse measurement direction identified via status output (or pulse output) Internal power supply for binary outputs U int = V DC / I 50 ma Pulse output Function continuous flow counting or measurement of sound velocity to determine (composition of) liquid product all operating data configurable galvanically isolated for active and passive mode Pulse rate for Q = 100% pulses/h pulses/min optionally in pulse per liter, m3, US gallons pulses/s (= Hz) } or user-defined unit Pulse width automatic: pulse duty cycle 1:1, max pulses/s = max Hz variable: 30, 50, 100, 200, 500 ms, 10 pulses/s 10 Hz Active mode connection: electronic counter internal voltage: V DC, from current output load current: I max < 50 ma, operation without status output Passive mode connection: electronic or electromechanical counter external voltage: U ext 32 V DC / 24 V AC Low-flow cutoff current load: I max 150 ma cutoff on value: 1 19% cutoff off value: 2 20% } of Q 100%, setting in 1% increments Time constant 0.04 s or same as current output Forward / reverse measurement direction identified via status output (or current output) Status output Function configure as indicator for flow direction, errors or operating mode Active mode internal voltage: U int V DC, from current output current load: I max < 50 ma, operation without pulse output Passive mode external voltage: U ext 32 V DC / 24 V AC current load: I max 150 ma Power supply 1. AC Version 2. AC Version AC / DC Version Standard Option Option 1. Rated voltage 230 / 240 V 200 V 24 V AC 24 V DC Tolerance band V V V AC V DC 2. Rated voltage 115 / 120 V 100 V Tolerance band V V Frequency Hz Hz Power consumption (incl. primary head) approx. 10 VA approx. 10 VA approx. 8 W When connected to functional extra-low voltage (24 V) safety separation (PELV) is essential (to VDE 0100 / VDE 0106 and IEC 364 / IEC 536 or equivalent national standards). Background Flowtubes UFM 500 Clamp-on UFM 600/610 Weld-om Open channel Gasflowtube GFM 700 Custody transfer ALTOSONIC V Calibration Installation notes Sizing guide Ordering guide / 5
6 UFM 800 Local display 3-field LCD Display function actual flowrate, measurement of sound velocity to determine (composition of) liquid product, forward, reverse and sum totalizer (7-digit) and status messages, each can be configured for continuous or sequential display Units: actual flowrate m 3, liter, US gallons per second, minute or hour, or in user-defined unit, e.g. liter/h or US gallon/day counter m 3, liter, US gallons or in user-defined unit, e.g. hecto liter or US million gallon (min. 1 year overflow time) Language of plain texts English, French, German, Dutch, others on request Display: 1st line (top) 8-character, 7-segment numeral and sign display, and symbols for key acknowledgement 2nd line (middle) 10-character, 14-segment text display 3rd line (bottom) 5 markers to identify display in measuring mode Housing Field housing Material aluminium with polyurethane finish Protection category (IEC 529/EN 60529) IP 67 equivalent to NEMA 6 (option IP 68) Sensor leads electrical connection between sensors and signal converter max. length: 50 m / 160 ft 6 /
7 Sizing guide Ordering guide UFM 800 for pipelines UFS 800 W Mounting location and installation Position the in the pipeline such that the measuring tube is completely filled with the process liquid at all times, even at zero flow velocity. Make sure that the measuring beam is approximately horizontal. Installation and alignment of FS 800 W ultrasonic sensors can be completed by KROHNE technicians. Install UFC 500 F signal converter in the vicinity of the measuring point (UFS 800 W sensors). Gas content The gas content in the process liquid must not exceed a maximum of 0.2% by volume at flowing conditions. Please note: Even in liquids that are virtually gas-free, large quantities of gas may form if the liquid is allowed to expand before reaching the measuring point, e.g. downstream of partially closed valves or small pump outlets. Inlet and outlet runs Single-beam Double-beam Inlet 20 x DN 10 x DN Outlet 5 x DN 10 x DN (DN = meter size, pipe diameter) Background Flowtubes UFM 500 Clamp-on UFM 600/610 Weld-om Open channel Gasflowtube GFM 700 for open channels UFS 800 C Mounting location and installation, Inlet run: 10 x B Outlet run: 5 x B (B = width of channel) Sensors can be installed either from the inside or the outside of the channel. Sensors aligned by KROHNE technicians are precisely set using laser alignment. Custody transfer ALTOSONIC V Calibration Installation notes / 7
8 UFM 800 Electrical connection, UFC 500 F (M 4.1) Power supply, power consumption and load rating of outputs: see Technical data (page 5) Current and pulse outputs (I + P) are galvanically isolated from all input and output circuits, when used in passive mode. Use the supplied signal cables (coaxial), length 5 m /16 ft, max. length 50 m /160 ft (optional), for the electrical connection between sensors and signal converter. Ambient temperature must be from 25 to +60 C ( 13 to +140 F), therefore do not cover signal converter with heat-insulating materials, and do not expose to strong sunlight or other heat sources. Avoid intensive vibration. Power supply V AC 24 V AC / DC binary outputs current output for internal use only (PE = protective conductor) (FE = functional ground) Current output I active Current output I passive Pulse output P active for passive EC with internal voltage from current output Pulse output P passive and status output S passive with external voltage U ext 32 V DC/ 24 V AC I 150 ma load U ext U ext R i 680 Ω U ext 18 V DC U int V DC EC or relay R i 680 Ω I 50 ma EMC (e.g. Siemens D1) R 650 Ω 8 /
IFC 010 Signal Converter
KROHNE 04/2003 7.02347.22.00 GR Signal Converter for electromagnetic flowmeters Easy to install Low-cost signal converter, measuring error < 0.5% of the measured value Easy user-friendly operation Self-monitoring
More informationElectromagnetic flowmeters and switches DWM 1000/2000
KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass
More informationVersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009
VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement
More informationBATCHFLUX and BATCHCONTROL
KROHNE 04/2001 D 31 BATC 02 E GR/PRINTO BATCHFLUX and volumetric batching and dosing with electromagnetic flowmeters A new era in volumetric batching!!! Optimum sanitary design Ceramic measuring tube Only
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationSITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI
Overview Integration The flowmeter pulse output is often used as input for heat calculators. The range of meters enables optimum measurement of energy consumption. The analog output is used to inform the
More informationOPTISONIC 7300 Technical Datasheet
OPTISONIC 7300 Technical Datasheet Ultrasonic gas flowmeter Wide application range No moving parts and no pressure loss Complete solution for gasflow measurement KROHNE CONTENTS OPTISONIC 7300 1 Product
More informationOPTISONIC 6300 Technical Datasheet
OPTISONIC 6300 Technical Datasheet Ultrasonic clamp-on flowmeter Robust industrial clamp-on construction Immediate start-up All in one concept KROHNE CONTENTS OPTISONIC 6300 1 Product features 3 1.1 Clamp-on
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationIFC 050 Technical Datasheet
IFC 050 Technical Datasheet Signal converter for electromagnetic flowmeters For water and wastewater applications Multiple outputs, incl. active pulse output and RS485 Modbus Excellent price/performance
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationBATCHFLUX 5500 C Technical Datasheet
BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only
More informationIFC 100 Technical Datasheet
IFC 100 Technical Datasheet Signal converter for electromagnetic flowmeters Simple and easy to install and start-up Diagnostics of device and application Extremely fast signal conversion The documentation
More informationWATERFLUX 3070 Technical Datasheet
WATERFLUX 3070 Technical Datasheet Engineered and manufactured for the water and wastewater industry Highly accurate measurement with extremely short in- and outlet lengths Battery operated, stand alone
More informationTIDALFLUX 2300 F Technical Datasheet
Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to
More informationIFC 050 Technical Datasheet
IFC 050 Technical Datasheet Signal converter for electromagnetic flowmeters For simple applications Multiple outputs, incl. active pulse output and RS485 Modbus Excellent price/performance ratio The documentation
More informationOPTIFLUX 1000 Technical Datasheet
OPTIFLUX 1000 Technical Datasheet Electromagnetic flow sensor in sandwich design Lightweight and compact Excellent price performance ratio Quick and easy to install The documentation is only complete when
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationOPTISONIC 7300 Technical Datasheet
OPTISONIC 7300 Technical Datasheet Ultrasonic gas flowmeter Wide application range No moving parts and no pressure loss Complete solution for gasflow measurement KROHNE CONTENTS OPTISONIC 7300 1 Product
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationOPTIMASS 1000 Technical Datasheet
OPTIMASS 1000 Technical Datasheet Sensor for mass flow First choice for universal applications Best price-performance ratio A wide range of options available with no restrictions The documentation is only
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationOPTISONIC Ultrasonic flowmeter for liquids in all industrial applications
OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature
More informationVersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications
VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications 34-VF-03-04 September 2011 The High-Performance Solution The TWC 9000 is a universal coriolis meter converter suitable for a wide
More informationIFC 050 Technical Datasheet
IFC 050 Technical Datasheet Signal converter for electromagnetic flowmeters For simple applications Multiple outputs, incl. active pulse output and RS485 Modbus Excellent price/performance ratio The documentation
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationOPTISONIC 6300 P Technical Datasheet
OPTISONIC 6300 P Technical Datasheet Portable ultrasonic clamp-on flowmeter User friendly operation through full colour graphic display and full keypad Quick and easy transfer of logged data to your PC
More informationFlow Measurement SITRANS F M
Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to
More informationFlow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview
Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationIFC 100 Technical Datasheet
IFC 100 Technical Datasheet Signal converter for electromagnetic flowmeters Simple and easy to install and start-up Diagnostics of device and application Extremely fast signal conversion The documentation
More informationOPTISONIC 3400 Technical Datasheet
OPTISONIC 3400 Technical Datasheet Measurement of (non- ) conductive, low and high viscous liquids, from -200 C to +250 C media temperature Accurate bi-directional measurement that starts from zero flow
More information2-Wire. Level Gauge BM 702
KROHNE 09/2001 7.02323.22.00 GR/PRINTO Level Gauge 2-Wire Level-Radar 2-Wire The first and only FMCW Radar Level Gauge with 2-wire technology The non-contact alternative to ageing technologies Maintenance-free
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationMaxxFlow HTC Flow Measurement for Dry Bulk Solids
EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed
More informationTechnical specification FLUXUS F401 H2O
Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationKFS. Flap-type flow meter. Design and range of application
Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is
More informationTechnical Information Proline Promag 10P
TI00094D/06/EN/13.17 71385977 Products Solutions Services Technical Information Electromagnetic flowmeter Flow measurement of liquids in chemical or process applications Application Electromagnetic flowmeter
More informationKMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)
KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%
More informationFLOMID FX Electromagnetic Flowmeter
FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics
More informationTechnical Specification FLUXUS ADM 8127B
FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere
More informationSITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009
Siemens AG 2009 SITRANS F flowmeters Rotary-piston meters Accessory modules Accessory modules For quantity measurements in conjunction with electromechanical and electronic pulse counters As transmitter
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationKMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display
Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationMFC 400 Technical Datasheet
MFC 400 Technical Datasheet Signal converter for mass flowmeters High performance signal converter for all applications Stable in multi-phase applications due to synthesised drive High developed diagnostic
More informationOPTISONIC 4400 Technical Datasheet
OPTISONIC 4400 Technical Datasheet Ultrasonic liquid flowmeter for high temperature and high pressure Accurate and repeatable measurement; long lasting and robust industrial design Efficient foil wave
More informationUTM10 Series Ultrasonic Transit-time Flowmeters
Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages
More informationMeasurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080
Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always
More informationProline Promag 10P. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications
Technical Information Proline Promag 10P Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications Application Electromagnetic flowmeter for bidirectional measurement
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationMFC 400 Technical Datasheet
MFC 400 Technical Datasheet Signal converter for mass flowmeters High performance signal converter for all applications, developed acc. to IEC 61508, SIL 2/3 Stable in multi-phase applications due to Entrained
More informationFLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual
SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS
More informationMFC 400 Technical Datasheet
MFC 400 Technical Datasheet Signal converter for mass flowmeters High performance signal converter for all applications Stable in multi-phase applications due to Entrained Gas Management (EGM ) High developed
More informationAdvanced instrumentation solutions crafted with highest precision
www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters
More informationPhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications
Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationMJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400
Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in
More informationElectromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P
Technical Information TI 049D/06/en 50097005 Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P Flow rate measurement in chemical or process applications Features and benefits
More informationElectro-Magnetic Flowmeters COPA-XE
Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates
More informationHTTF Transit Time Ultrasonic Flow Meter
Transit Time Ultrasonic Flow Meter Reduced material costs: clamp-on sensor eliminates the need for in-line flanges, pipe fittings, strainers, and filters Reduced installation time: the may be installed
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI
Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is
More informationOPTISONIC 6300 Quick Start
OPTISONIC 6300 Quick Start Ultrasonic clamp-on flowmeter ER 3.4.0_ KROHNE CONTENTS OPTISONIC 6300 1 Installation 4 1.1 Intended use... 4 1.2 Scope of delivery... 4 1.3 Overview... 5 1.4 Storage... 5 1.5
More informationDosimass. Technical Information. Coriolis Mass Flow Measuring System For filling applications
Technical Information Coriolis Mass Flow Measuring System For filling applications Application Suitable for use as a mass or volume flowmeter for filling applications. Liquids with the most diverse properties
More informationTechnical Specification FLUXUS ADM 8x27
Ultrasonic Flow Measurement of Liquids in Explosive Atmosphere Features Transducers non-invasive (no contact with the medium, no need for expensive materials) wearfree no pressure drop (no operational
More informationUltrasonic Level Transducer Type: MPUL06 Article No.: ca. 122
Type: Article No.: 0067720.006 Dimensions ø95 PG7 45.25 16 101 ca. 122 ø53 NPS 2" Figure 1: Ultrasonic Level Transducer Description and application The MPULxx is an ultrasonic transducer used for determining
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationProline Promass 40E. Technical Information
Technical Information Coriolis Mass Flow Measuring System The mass flow measuring system with low cost and basic functionality. The economical alternative to conventional volume flowmeters. Application
More informationSITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI
Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two
More informationFlow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.
Flow Technologies Overview Mag Flow MAGFLO Program Siemens offers a comprehensive selection of electromagnetic flow meters Water & waste water Chemical Food & beverage Mining Aggregates Cement Pharmaceutical
More informationULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement
ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp
More informationTechnical specification FLUXUS WD
Technical specification FLUXUS WD Non-invasive ultrasonic flow measurement on buried pipes Permanently installed clamp-on ultrasonic flow measurement system for buried water and wastewater pipes Features
More informationEfcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK
Efcon Water Installation & User Manual Electro Magnetic Flowmeter (EMF) Page 1 Table of content Page 1.1 General 3 1.2 Application area 4 1.3 Transportation 4 1.4 Principle of Operation 4 1.5 Product Description
More informationFlow Measurement SITRANS F US Inline
Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,
More informationTZIF 4. Current-to-Pulse Converter 10/ EN
TZIF 4 Current-to-Pulse Converter Conversion of direct current or voltage signals into a proportional pulse frequency Integration and average value formation of analog signals for quantity counting/remote
More informationClamp-on ultrasonic flowmeters have six product families: max. 2% solids
System info and selection guide Ultrasonic flowmeters Overview Siemens offers two types of ultrasonic flowmeters, wetted flowmeters and clamp-on flowmeters. This offers the end user the maximum flexibility
More informationApplications Features
GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system
More informationIFC 300 Technical Datasheet
IFC 300 Technical Datasheet Signal converter for electromagnetic flowmeters Diagnostics: Process and device diagnostics, accuracy check One signal converter for all applications Exceeds requirements of
More informationMFC 300 Technical Datasheet
MFC 300 Technical Datasheet Signal converter for mass flowmeters Modular signal converter concept and the same hardware for all housing designs Double redundancy of the calibration data Stainless steel
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationTechnical Information Proline Promag 55S
TI00071D/06/EN/14.17 71385973 Products Solutions Services Technical Information Electromagnetic flowmeter The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics Application
More informationSITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9
Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.
More informationULTRASONIC FLOW METER FT101
Introduction F t101 is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationDigital batch controller
INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationTransit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P
Technical Information TI 056D/24/ae Transit Time Ultrasonic Flow Measuring System PROline prosonic flow 93 P Volume flow measurement of liquids in chemical or process applications Features and benefits
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationRCM DIRECT READING FLOWMETER
RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:
More informationOPTIFLUX 1000 Handbook
OPTIFLUX 1000 Handbook Electromagnetic flow sensor in sandwich design The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE : IMPRINT
More informationOPTITEMP TT 20 Technical Datasheet
OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is
More informationVortex Flow Measuring System prowirl 77
Technical Information TI 040D/06/en No. 50084974 Vortex Flow Measuring System prowirl 77 Reliable Flow Measurement of Gases, Steam and Liquids Safe Verified electromagnetic compatibility according to IEC
More informationProline Promag 55S. Technical Information
Technical Information Proline Promag 55S Electromagnetic Flow Measuring System Flow rate measurement of liquids with solids content or inhomogeneous liquids Application Electromagnetic flowmeter for bidirectional
More informationFlow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview
Flowmeter SITRANS FUS380 standard Overview Design The 2-track design of SITRANS FUS380 ensures maximum accuracy under short inlet conditions. The flowmeter consists of a flow sensor pipe, transducers/transducer
More informationCoriolis Mass Flow Measuring System promass 40 E
Technical Information TI 055D/06/en 50098284 Coriolis Mass Flow Measuring System promass 40 E The new mass flow measuring system with low cost and basic functionality the economical alternative to conventional
More informationCoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter
Data Sheet DS/FCB300/FCH300-EN Rev. H CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter 4-wire compact device For flow measurement of liquids and gases Measurement made easy CoriolisMaster
More informationDigital flow transmitter for continuous flow measurement
Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:
More informationIFC 100 / IFC 300. Electromagnetic flow converters for the OPTIFLUX series
IFC 100 / IFC 300 Electromagnetic flow converters for the OPTIFLUX series 4 The most innovative converter line 4 IFC 100 for all standard applications 4 IFC 300 the high-end device even for difficult applications
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More information