MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.A. PERERA
|
|
- Chastity Farmer
- 5 years ago
- Views:
Transcription
1 MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.A. PERERA
2 SRI LANKA Government type: Democratic Socialist Republic Capital city: Sri Jayawardenapura Location: South Asia Area: 65,610 sq km Population: 20,653,000 Religion: Buddhist (69.3%); Hindu (15.5%); Muslim (7.5%); Christianity (6.9%), other (0.8%) Languages: Sinhala, Tamil, English Climate: tropical and warm / 25 C - 30 C Natural Resources: Granite, Gems, phosphate, Dolomite, Mineral sand, Sea around the island (Fish, salt, etc..) Main industries: Plantations and Agriculture (Rice, Tea, Rubber, Coconut, Cinn amon, coffee, Sugar), Garment & Apparel, Construction sector, Food producti on & Processing
3 MEASUREMENT UNITS, STANDARDS AND SERVICES DEPARTMENT Measurement Units, Standards & Services Department (MUSSD) was established in 1997 to implement the Measurement Units Standards & Services Act No 35 of (The department earlier established as weights and measure division of the depart ment of Internal trade which was established in 1952 to implement weights and me asure ordinance No 37 of 1946 engaged mainly on legal metrology) The Act Empowers MUSSD to engage in, Fundamental metrology Industrial metrology Legal metrology In 1976, National Metric Conversion Law was established to realize the Units based on International System (SI units). In 2007 MUSSD singed the International Mutual Recognition Agreement (MRA) between National Metrology Institutes (NMIs).
4 NEW MUSSD LABORATORY BUILDING COMPLEX 2015 DECEMBER 08 Location: Pitipana, Mahenawatta, Homagama, Sri Lanaka Shifted to new laboratory on
5 TIME AND FREQUENCY LABORATORY Equipment Time and Frequency Standard system: Cs Primary frequency standard (Micro semi 5071A Cs primary frequency standard), Rubidium Atomic standard (Fluke 910R GPS Controlled Rubidium Reference Clock), Time interval counter with rubidium oscillator (Fluke PM 6681R Rubidium Frequency Reference/Counter/Calibrator) Time dissemination system: NTP time servers stratum 1 and 2(LAN time M600GPS/MRS NTP Stratum 1Time Server), web server for time display Time transfer system: GNSS receiver (Polar RX4-TR), Choke ring antenna Time and Frequency calibration system: Signal Generator, Digital Storage Oscilloscope, Timer and Stopwatch calibration software with NTP server Staff Two Metrologists (MSC, Physics Special), two experimental officers (BSc Degree with Physics as a final year subject), one Lab helper (GCE. A/L)
6
7 CURRENT TIME AND FREQUENCY STANDARD AND DISSEMINATION SYSTEM EQUPMENTS Fluke 910R GPS Controlled Rubidium Reference Clock Fluke PM 6681R Rubidium Frequency Reference/Counter/Calibrator Meinberg LAN time M600MRS NTP Stratum 1Time Server Meinberg LAN time M600GPS NTP Stratum 1Time Server Two web servers with stratum 2 NTP servers to maintain the time information website. GNSS Receiver (Septrintrio polar RX4TR), 3 pulse and frequency distribution amplifiers Microsemi 5071A Cs primary frequency standard
8 RESPONSIBILITIES AND EXPERIENCE OF THE PARTICIPANT Educational Background: Physics, Electronics and Telecommunication Engineering. Responsibilities: 1) Maintaining, development and dissemination of National standards for DC electricity and Time and frequency parameters and Gas standards (Head of the above laboratories). 2) Type approval of weighing and measuring instruments used for trade. 3)Training Laboratory and other staff in legal metrology Experience: 1) Working in Electrical and Time and frequency field since 2010(6years) in NML Sri Lanka 2) 5 Year experience as a ISO/IEC17025 technical assessor under Sri Lanka Accreditation board
9 CURRENT ACTIVITIES OF TIME AND FREQUENCY LABORATORY Maintaining and disseminating Sri Lanka Standard Time (Regulation: Sri Lanka Standard Time Regulation 2011) Maintaining National standard for frequency Calibration services to industry and calibration, testing and medical laboratories (Stopwatches, timers, rpm meters, centrifuges, function generators, oscilloscopes, other timing and time interval measuring instruments used in government authorities and industry) (Number of calibrations: 65 items/year)
10 FUTURE PLANS Establish CMCs for time interval and frequency parameters (2018) Participate for regional Time and frequency inter comparisons Established time and frequency standards according to APMP guide lines for minimum requirements of equipment and inter comparisons to participate for deterring UTC, (purchasing necessary equipment, Technical support from other NMIs) (2016 to 2020) Train more staff members and raise awareness about T&F field to increase research activities combine with local universities. Establishing a time stamping service combine with the intellectual property registration department(2017). Establishing time code radio distribution station with using existing AM radio stations and antenna sites not using currently.(2017,2018)
11 PROBLEMS IN SETTING THE GPS TIME TRANSFER SYSTEM AND CALIBRATION Equipment: currently, one Cs clock available, (How to setup reference 10MHz for time transfer with GNSS receiver, Currently used Rubidium frequency reference) GNSS receiver internal delay and attitude value determination Lightning protection of GPS antenna and receiver Cable delay determination when the cables are already installed (best method)
12 THANK YOU
MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA
COUNTRY REPORT: MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.ANURADHA. PERERA SRI LANKA Government type: Democratic Socialist Republic Location: South Asia,
More informationTime and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD- Sri Lanka
Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD- Sri Lanka Introduction Measurement Units, Standards and Services Department (MUSSD
More informationTime and Frequency Laboratory Measurement Units, Standards. (National Metrology Institute) MUSSD-Sri Lanka
Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD-Sri Lanka Introduction Measurement Units, Standards and Services Department (MUSSD
More informationActivity Report of Time and Frequency Laboratory, NMIM (formally known as NML-SIRIM), Malaysia
Activity Report of Time and Frequency Laboratory, NMIM (formally known as NML-SIRIM), Malaysia Dr. Mohd. Nasir Senior Principal Metrologist Ahmad Sahar Senior Metrologist Mohd Rafiq Metrologist Mohd Izzulfitri
More informationMongolian Agency for Standardization and Metrology Time Frequency Lab. Unurbileg Darmaa Head, Length & Time and Frequency lab MASM
Mongolian Agency for Standardization and Metrology Time Frequency Lab Unurbileg Darmaa Head, Length & Time and Frequency lab MASM 2017-10-26 11/13/2017 Mongolian Agency for Standardization and Metrology
More informationSTATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE)
STATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE) Trieu Viet Phuong Head of Time and Frequency Laboratory, VMI Email: phuongtv@vmi.gov.vn DA NANG 11-2016 About TFL Laboratory of time
More informationDEC Workshop on Participation in Co-ordinated Universal Time
Report (Philippines) DEC Workshop on Participation in Co-ordinated Universal Time 6 7 November 2014 NIM, Beijing, China Sabino Paulo B. Leones, Jr. National Metrology Laboratory (NML) Industrial Technology
More informationTIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY
TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY E. L. Marais and B. Theron CSIR National Metrology Laboratory PO Box 395, Pretoria, 0001, South Africa Tel: +27 12 841 3013; Fax:
More informationNPLI Report. for. Technical workshop and inter-laboratory comparison exercise for GPS time-transfer and calibration techniques under MEDEA
NPLI Report for Technical workshop and inter-laboratory comparison exercise for GPS time-transfer and calibration techniques under MEDEA Dr. V. N. Ojha, Dr. A. Agarwal, Mrs. D. Chaddha, Dr. S. Panja, Dr.
More informationREPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)
Nguyen Bang Head of Time and Frequency Laboratory (TFL) Vietnam Metrology Institute (VMI) N 0 8, Hoang Quoc Viet Road, Caugiay District, Hanoi, Vietnam About Time & Frequency Laboratory (TFL) Time and
More informationCURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD.
CURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD., TAIWAN C. S. Liao, P. C. Chang, and S. S. Chen National Standard
More informationREPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)
Trieu Viet Phuong Deputy head of Time and Frequency Laboratory (TFL) Vietnam Metrology Institute (VMI) N 0 8, Hoang Quoc Viet Road, Caugiay District, Hanoi, Vietnam About Time & Frequency Laboratory (TFL)
More informationStatus Report on Time and Frequency Activities at CSIR-NPL India
Status Report on Time and Frequency Activities at CSIR-NPL India (APMP -TCTF 2016) S. Panja, A. Agarwal, D. Chadha, P. Arora, P. Thorat, S. De, S. Yadav, P. Kandpal, M. P. Olaniya and V. N. Ojha (Da Nang,
More informationStatus Report on Time and Frequency Activities at National Physical Laboratory India
Status Report on Time and Frequency Activities at National Physical Laboratory India (TCTF 2015) Ashish Agarwal *, S. Panja. P. Arora, P. Thorat, S. De, S. Yadav, P. Kandpal, M. P. Olaniya, S S Rajput,
More informationReport of the TC Time and Frequency. Ramiz Hamid TC-TF Chair, TÜBİTAK UME, Turkey
Report of the TC Time and Frequency Ramiz Hamid TC-TF Chair, TÜBİTAK UME, Turkey Contents TC-TF meeting and T&F strategy EMRP Projects and future optical redefinition of the second Time scale generation
More informationStatus Report on Time and Frequency Activities at NPL India
Status Report on Time and Frequency Activities at NPL India (APMP TCTF 2013) A. Sen Gupta, A. Chatterjee, A. K. Suri, A. Agarwal, S. Panja P. Arora, S. De, P. Thorat, S. Yadav, P. Kandpal, M. P. Olaniya
More informationTraceability measurement results of accurate time and frequency in Bosnia and Herzegovina
INFOTEH-JAHORINA Vol. 11, March 2012. Traceability measurement results of accurate time and frequency in Bosnia and Herzegovina Osman Šibonjić, Vladimir Milojević, Fatima Spahić Institute of Metrology
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Revised By: Specialist Technical Committee
More informationExpert Site Visit Report
Expert Site Visit Report Time and Frequency Metrology Sub Division Research Center for Metrology Indonesian Institute of Sciences RCM LIPI Metrology Enabling Developing Economies in Asia, MEDEA Project
More informationTime and Frequency Research Activity in NIM
Time and Frequency Research Activity in NIM Gao Xiaoxun National Institute of Metrology Bei San Huan Dong Lu No.18 Beijing P.R.China Abstract This paper will introduce scientific research activities in
More informationTIME & FREQUENCY SERVICES IN MALAYSIA
TIME & FREQUENCY SERVICES IN MALAYSIA Presented by : Mohd Rafiq Bin Abdul Kamal Metrologist National Metrology Laboratory SIRIM Berhad, Malaysia Time & Frequency Laboratory National Metrology Laboratory
More informationILAC input to CIPM MRA Review Workshop October 2015
ILAC input to CIPM MRA Review Workshop 13-14 October 2015 BIPM Sevres 13 October 2015 By Erik Oehlenschlaeger ILAC (DANAK) ILAC History ILAC first started as a conference in 1977 (Copenhagen) with the
More informationLITHUANIAN NATIONAL TIME AND FREQUENCY STANDARD
LITHUANIAN NATIONAL TIME AND FREQUENCY STANDARD Rimantas Miškinis Semiconductor Physics Institute A. Goštauto 11, Vilnius 01108, Lithuania Tel/Fax: +370 5 2620194; E-mail: miskinis@pfi.lt Abstract The
More informationSoftware configuration Precise antenna positioning. Software configuration Precise antenna positioning
Precise antenna positioning 43 Precise antenna positioning 44 36 Precise antenna positioning 44 Precise antenna positioning 44 37 Precise antenna positioning The US National Oceanic and Atmospheric Administration
More informationHaruo Saito. National Institute of Information and Communications Technology
Calibration system at NICT Haruo Saito National Institute of Information and Communications Technology Organization of NICT Content Calibration system Calibration system Carried in system and remote system
More informationNMI's Role and Expertise in Synchronization Applications
NMI's Role and Expertise in Synchronization Applications Wen-Hung Tseng National Time and Frequency standard Lab, Telecommunication Laboratories, Chunghwa Telecom Co., Ltd., Taiwan APMP 2014 Time-transfer
More informationSpecific Accreditation Criteria Calibration ISO/IEC Annex. Electrical metrology
Specific Accreditation Criteria Calibration ISO/IEC 17025 Annex Electrical metrology January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected by
More informationActivity report from NICT
Activity report from NICT APMP 2013 / TCTF meeting 25-26 November, 2013 National Institute of Information and Communications Technology (NICT) Japan 1 1 Activities of our laboratory Atomic Frequency Standards
More informationUpgradation and Strengthening of National Time Scale of India
Upgradation and Strengthening of National Time Scale of India (ATF 2017) Ashish Agarwal, P. Thorat, M. P. Olaniya, S. Yadav, P. Kandpal, P. Arora, S. Panja, S. De, T. Bharadwaj, N. Sharma, S. Kazim, B.
More informationAn Experiment Study for Time Synchronization Utilizing USRP and GNU Radio
GNU Radio Conference 2017, September 11-15th, San Diego, USA An Experiment Study for Time Synchronization Utilizing USRP and GNU Radio Won Jae Yoo, Kwang Ho Choi, JoonHoo Lim, La Woo Kim, Hyoungmin So
More informationCertificate of Calibration No
Federal Department of Justice olice FDJP Federal Office of Metrology METAS Certificate of Calibration No 7-006 Object GPS rcvr type Septentrio PolaRx4TR PRO serial 005 Antenna type Aero AT-675 serial 500
More informationGPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard
GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Standard Key Features Completely self-contained unit. No extra P.C needed. Full information available via LCD. Rubidium Oscillator locked
More informationCER-ASEAN Integration Partnership Forum. CER-ASEAN participation in global frameworks for international recognition and harmonisation of measurement
CER-ASEAN Integration Partnership Forum CER-ASEAN participation in global frameworks for international recognition and harmonisation of measurement Dr Angela Samuel Director, International Relations Mr
More informationOutline. Introduction Laboratory Status Activities Future Plans
Laboratory Report Time and Frequency Metrology Sub Division Research Center for Metrology Indonesian Institute of Sciences RCM LIPI Metrology Enabling Developing Economies in Asia, MEDEA Project for GPS
More informationDEC Country Report. National Institute of Metrology (Thailand) By Mr.Pairoj Rattanangkul
National Institute of Metrology (Thailand) DEC Country Report By Mr.Pairoj Rattanangkul email : pairoj@nimt.or.th National Institute of Metrology (Thailand) 1 2 Table of Content Brief history of NIMT Where
More informationTraceability in Time and Frequency Metrology
Traceability in Time and Frequency Metrology Michael A. Lombardi National Institute of Standards and Technology Time and Frequency Division 325 Broadway Boulder, CO 80303 United States of America (303)
More informationJoint ILAC CIPM Communication regarding the. Accreditation of Calibration and Measurement Services. of National Metrology Institutes.
Joint ILAC CIPM Communication regarding the Accreditation of Calibration and Measurement Services of National Metrology Institutes 7 March 2012 Authorship This document was prepared by the International
More informationHOW TO RECEIVE UTC AND HOW TO PROVE ACCURACY
HOW TO RECEIVE UTC AND HOW TO PROVE ACCURACY Marc Weiss, Ph.D. Independent Consultant to Booz Allen Hamilton Weiss_Marc@ne.bah.com Innovation center, Washington, D.C. JANUARY 23, 2018 HOW DO YOU GET UTC
More informationTime & Frequency Transfer
Cold Atoms and Molecules & Applications in Metrology 16-21 March 2015, Carthage, Tunisia Time & Frequency Transfer Noël Dimarcq SYRTE Systèmes de Référence Temps-Espace, Paris Thanks to Anne Amy-Klein
More informationCalibration Specialists Ltd
The National Technological Park, Castletroy, Limerick Calibration Laboratory Registration number: 001C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in the Schedule
More information33 rd Asia Pacific Metrology Programme General Assembly 30 November 1 December 2017 New Delhi, India
33 rd Asia Pacific Metrology Programme General Assembly 30 November 1 December 2017 New Delhi, India Laboratory Report National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 BHD Test & ment 2100 W. 6th Ave. Broomfield, CO 80020 Everett Hedrick Phone: 303 469 5335 CALIBRATION Valid to: May 31, 2019 Certificate
More informationCountry Profile China
Country Profile China Introduction Location Capital Eastern Asia, bordering the East China Sea, Korea Bay, Yellow Sea, and South China Sea, between North Korea and Vietnam Beijing Area 9,596,960 sq. km
More informationGPS10R - 10 MHz, GPS Disciplined, Rubidium Frequency Standards
GPS10R - 10 MHz, GPS Disciplined, Rubidium Standards Key Features Completely self-contained units. No extra P.C Multiple 10 MHz Outputs plus other outputs needed. Full information available via LCD. RS232
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 Caliber Test & ment 2100 W. 6th Ave. Broomfield, CO 80020 Everett Hedrick Phone: 303 469 5335 CALIBRATION Valid to: May 31, 2019 Certificate
More informationAPMP GUIDELINES FOR ACCEPTING A QUALITY SYSTEM(V.2.0 WD2) approved on July 2010
APMP GUIDELINES FOR ACCEPTING A QUALITY SYSTEM(V.2.0 WD2) approved on July 2010 The CIPM global mutual recognition arrangement (global MRA) requires national metrology institutes (NMIs) to have in place
More informationGPS10RBN - 10 MHz, GPS Disciplined Rubidium Frequency Standard
GPS10RBN - 10 MHz, GPS Disciplined Rubidium Standard Completely self-contained unit. No extra P.C needed. Full information available via LCD. Rubidium Oscillator locked to GPS satellite signal. Accuracy
More informationTHE FIRST TWO-WAY TIME TRANSFER LINK BETWEEN ASIA AND EUROPE
35 th Annual Precise Time and Time Interval (PTTI) Meeting THE FIRST TWO-WAY TIME TRANSFER LINK BETWEEN ASIA AND EUROPE H. T. Lin, W. H. Tseng, S. Y. Lin, H. M. Peng, C. S. Liao Telecommunication Laboratories,
More informationEXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947
EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947 7.1 RF Power -- Pursuant to 47 CFR 2.947(c) Method of Conducted Output Power Measurement: Adaptation of TIA/EIA-603-A clause 2.2.1 for Pulsed Measurements
More informationRemote Frequency Calibration Service at NMIJ
Remote Frequency Calibration Service at NMIJ Case Example for APMP-WS 2014 Frequency Measurement Systems Section National Metrology Institute of Japan (NMIJ), AIST, JAPAN Content Introduction Overview
More information2-5 Frequency Calibration
2-5 Frequency SAITO Haruo, IWAMA Tsukasa, TSUCHIYA Shigeru, and KOYAMA Yasuhiro The Japan Standard Time (JST) and the Coordinated Universal Time (UTC(NICT)), which are constructed by National Institute
More informationFor the National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Masy BioServices 27 Lomar Park Drive Pepperell, MA 01463-1486 Mr. Keith Kelly Phone: 978-433-6279 Fax: 978-433-0442 E-mail: keith.kelly@masy.com URL: http://www.masy.com
More informationCIPM and CCPR What are these organizations and how do they affect my testing results. Maria Nadal Photometry, Surface Color and Appearance NIST
CIPM and CCPR What are these organizations and how do they affect my testing results Maria Nadal Photometry, Surface Color and Appearance NIST CIE USA Annual Meeting October 6-7, 2014 Calibration Laboratory
More informationFor the National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Transcat San Juan 281 Calle Matadero Urb Puerto Nuevo San Juan, PR 00920 Mr. Brian Samuelson Phone: 787-706-8855 Fax: 787-792-3614 E-mail: bsamuelson@transcat.com
More informationEvaluation of timing GPS receivers for industrial applications
12th IMEKO TC1 Workshop on Technical Diagnostics June 6-7, 213, Florence, Italy Evaluation of timing GPS receivers for industrial applications Vojt ch Vigner 1, Jaroslav Rozto il 2, Blanka emusová 3 1,
More informationNational time scale UTC(SU) and GLONASS system time scale: current status and perspectives
State Scientific Center of the Russian Federation National Research Institute for Physical-Technical and Radio Engineering Measurements National time scale UTC(SU) and GLONASS system time scale: current
More informationTime and Frequency Activities at NICT, Japan
Time and Frequency Activities at NICT, Japan Yasuhiro Koyama, Kuniyasu Imamura, Tsukasa Iwama, Shin'ichi Hama, Jun Amagai, Ryuichi Ichikawa, and Mizuhiko Hosokawa National Institute of Information and
More informationBorderline between CIPM MRA and testing activities
Borderline between CIPM MRA and testing activities Michela Sega, EURAMET TC-MC Chair INRIM-Italy 7 th Meeting of the Focus Group on Facilitating National Metrology Infrastructure Development Zagreb, Croatia,
More informationMEASUREMENT AND STANDARDS
MEASUREMENT AND STANDARDS I. MEASUREMENT PRINCIPLES 1. MEASUREMENT SYSTEMS Measurement is a process of associating a number with a quantity by comparing the quantity to a standard Instrument refers to
More informationBuilding a 10Mhz GPS Disciplined Oscillator. Lucas Ford W6AER
Building a 10Mhz GPS Disciplined Oscillator Lucas Ford W6AER Add a Slide Title - 1 Here is the one I will be discussing today What it is - Why you may need one How to Build one! What in the world is a
More informationDesignated Institutes participating in the CIPM MRA
Designated Institutes participating in the CIPM MRA Expectations and nomination form Version 1.2 Contents 1. Introduction... 1 2. Designated Institute in Appendix A of the KCDB... 2 2.1. Designation of
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z540.3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3 SIMCO ELECTRONICS (Ireland) Limited IDA Business & Technology Park Garrycastle, Dublin Rd Athlone Westmeath, Ireland
More informationCertificate of Accreditation
PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 EXPHIL CALIBRATION LABS, INC. 415 Central Avenue Bohemia, NY 11716 Steven Pidd Phone: 631 563 3520 CALIBRATION
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 JM TEST SYSTEMS, INC. 3947 Lincoln Ave., Ste. B Groves, TX 77619 Jerry Kraus Phone: 432 580 7040 CALIBRATION Valid To: February 29,
More informationFor the National Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SET Y GAD SAS METROLOGY LABORATORY CARRERA 48 # 101A - 69 Bogotá, Colombia Mr. Steven Mesa Phone: 57 1 7559277 E-mail: steven.mesa@setgad.com Fields of Calibration
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 EXPHIL CALIBRATION LABS, INC. 415 Central Avenue Bohemia, NY 11716 Steven Pidd Phone: 631 563 3520 CALIBRATION Valid To: October 31,
More informationNew precise timing solutions and their application in JUNO project Jauni precīzā laika risinājumi un to izmantošana JUNO projektā
New precise timing solutions and their application in JUNO project Jauni precīzā laika risinājumi un to izmantošana JUNO projektā Vadim Vedin Institute of Electronics and Computer Science Riga, Latvia
More informationPRECISE RECEIVER CLOCK OFFSET ESTIMATIONS ACCORDING TO EACH GLOBAL NAVIGATION SATELLITE SYSTEMS (GNSS) TIMESCALES
ARTIFICIAL SATELLITES, Vol. 52, No. 4 DOI: 10.1515/arsa-2017-0009 PRECISE RECEIVER CLOCK OFFSET ESTIMATIONS ACCORDING TO EACH GLOBAL NAVIGATION SATELLITE SYSTEMS (GNSS) TIMESCALES Thayathip Thongtan National
More informationWhite Rabbit in Time & Frequency Metrology
VTT TECHNICAL RESEARCH CENTRE OF FINLAND LTD White Rabbit in Time & Frequency Metrology Anders Wallin White Rabbit Workshop 2016-03-15, Amsterdam Long(est?) WR link Fiber asymmetry and calibration Stability
More informationTime Traceability for the Finance Sector Fact Sheet
Time Traceability for the Finance Sector Fact Sheet Version 1.4 14 March 2016 NPL Management Ltd is a company registered in England and Wales No. 2937881 Registered Office: NPL Management Ltd, Hampton
More informationPRELIMINARY RESULTS OF THE TTS4 TIME TRANSFER RECEIVER INVESTIGATION
PRELIMINARY RESULTS OF THE TTS4 TIME TRANSFER RECEIVER INVESTIGATION N. Koshelyaevsky and I. Mazur Department of Metrology for Time and Space FGUP VNIIFTRI, MLB, 141570, Mendeleevo, Moscow Region, Russia
More informationTIME COORDINATION THROUGHOUT THE AMERICAS VIA THE SIM COMMON-VIEW GPS NETWORK
TIME COORDINATION THROUGHOUT THE AMERICAS VIA THE SIM COMMON-VIEW GPS NETWORK Michael A. Lombardi a, Andrew N. Novick a, J. Mauricio Lopez R. b, Jean-Simon Boulanger c, Raymond Pelletier c, and Carlos
More informationFeasibility Studies of Time Synchronization Using GNSS Receivers in Vehicle to Vehicle Communications. Queensland University of Technology
Feasibility Studies of Time Synchronization Using GNSS Receivers in Vehicle to Vehicle Communications Khondokar Fida Hasan Professor Yanming Feng Professor Glen Tian Queensland University of Technology
More informationNov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time. Aimin Zhang National Institute of Metrology (NIM)
Nov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time Aimin Zhang National Institute of Metrology (NIM) Introduction UTC(NIM) at old campus Setup of new UTC(NIM) Algorithm of UTC(NIM)
More informationL.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI
L.S. Compliance, Inc. W66 N220 Commerce Court Cedarburg, WI 53012 262-375-4400 COMPLIANCE TESTING OF: Quartex Synchronization Transmitter Model FM-72 PREPARED FOR: Quartex, Division of Primex, Inc. 965
More informationEstablishing Traceability to UTC
White Paper W H I T E P A P E R Establishing Traceability to UTC "Smarter Timing Solutions" This paper will show that the NTP and PTP timestamps from EndRun Technologies Network Time Servers are traceable
More informationSMD ENS Metrology - National Standards. Short overview. Hugo Pirée. World Metrology Day 2018 Brussels.
SMD ENS Metrology - National Standards Short overview Hugo Pirée World Metrology Day 2018 Brussels Federal government FPS ECONOMY Gen. Direction QUALITY & SAFETY Division METROLOGY 14 persons National
More informationMETAS TIME & FREQUENCY METROLOGY REPORT
METAS TIME & FREQUENCY METROLOGY REPORT Laurent-Guy Bernier METAS Federal Office of Metrology Lindenweg 50, Bern-Wabern, Switzerland, CH-3003 E-mail: laurent-guy.bernier@metas.ch, Fax: +41 31 323 3210
More informationCorrect Measurement of Timing and Synchronisation Signals - A Comprehensive Guide
Correct Measurement of Timing and Synchronisation Signals - A Comprehensive Guide Introduction This document introduces the fundamental aspects of making valid timing and synchronisation measurements and
More informationNational Voluntary Laboratory Accreditation Program
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Transcat St. Louis 527 Mae Court Fenton, MO 63026 Mr. Jim Beckner Phone: 636-349-7722 Fax: 636-349-4590 E-mail: jbeckner@transcat.com URL: www.transcat.com
More informationCalibration Laboratory Assessment Service CLAS Certificate Number Page 1 of 10
Calibration Laboratory Assessment Service CLAS Certificate Number 95-02 Page 1 of 10 400 Britannia Road East, Unit #1 Mississauga, Ontario L4Z 1X9 Contact: Mr. Vince Casali Tel (905) 890-7600, (800) 36FLUKE
More informationTime and Frequency Activities at KRISS
Time and Frequency Activities at KRISS Dai-Hyuk Yu Center for Time and Frequency Metrology, Division of Physical Metrology Korea Research Institute of Standards and Science (KRISS) dhyu@kriss.re.kr Time
More informationTime and Frequency Activities at KRISS
Time and Frequency Activities at KRISS Dai-Hyuk Yu Center for Time and Frequency, Division of Physical Metrology Korea Research Institute of Standards and Science (KRISS) dhyu@kriss.re.kr Time and Frequency
More informationInfluence of GPS Measurements Quality to NTP Time-Keeping
Influence of GPS Measurements Quality to NTP Time-Keeping Vukan Ogrizović 1, Jelena Gučević 2, Siniša Delčev 3 1 +381 11 3218 582, fax: +381113370223, e-mail: vukan@grf.bg.ac.rs 2 +381 11 3218 538, fax:
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 JEL LIMITED 2971 Nakabyo, Abiko-City Chiba-Prefecture, 270-1121, JAPAN Keiichiro Murata Phone: +81 4 7188 5333 Email: murata@jel.co.jp CALIBRATION Valid To:
More informationPower Quality Measurements the Importance of Traceable Calibration
Power Quality Measurements the Importance of Traceable Calibration H.E. van den Brom and D. Hoogenboom VSL Dutch Metrology Institute, Delft, the Netherlands, hvdbrom@vsl.nl Summary: Standardization has
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 SIMCO ELECTRONICS - DRAPER, UTAH 65 E. Wadsworth Park Drive Suite 101 Draper, UT 84020 Curtis Keller Phone:
More informationActivity report from NICT
Activity report from NICT APMP 2017 / TCTF meeting 27-28 November, 2017 National Institute of Information and Communications Technology (NICT) Japan 1 1 Space time standards laboratory Atomic Frequency
More informationProgramme of work and budget for Plans for Time Department
Programme of work and budget for 2013-2015 Plans for 2016-2019 Time Department Elisa Felicitas Arias 101 th Meeting of the CIPM, Session 1 BIPM, Sèvres, 8 June 2012 Programme of work 2013-2015 Continues
More informationBureau International des Poids et Mesures. International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA
Bureau International des Poids et Mesures International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA Prof. Michael Kühne International School of Physics Enrico Fermi Metrology
More informationButler Technologies. Unit 14, Block G, Maynooth Business Campus, Co. Kildare, Ireland. Calibration Laboratory Registration number: 256C
Unit 14, Block G, Maynooth Business Campus, Co. Kildare, Ireland Calibration Laboratory Registration number: 256C is accredited by the Irish National Board (INAB) to undertake calibration as detailed in
More informationCCTF 2012 Report on Time & Frequency activities at National Physical Laboratory, India (NPLI)
CCTF 2012 Report on Time & Frequency activities at National Physical Laboratory, India (NPLI) Major activities of the Time & Frequency division of NPLI in the last three years have been: 1. Maintenance
More information6135A/PMUCAL Phasor Measurement Unit Calibration System
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) 6135A/PMUCAL Phasor Measurement Unit Calibration System Fast, automated, traceable calibrations that comply with IEEE
More informationNdwakhulu Mukhufhi CEO
Ndwakhulu Mukhufhi CEO Outline of Talk Africa Continent of Wonders (+ve & ve) Challenges in Emerging Economies The Intra African System of Metrology The CIPM MRA in Africa What is Needed to grow Metrology?
More informationThe Open University of Sri Lanka
The Open University of Sri Lanka The Open University of Sri Lanka (OUSL) was established in 1980 under the University Act No.16 of 1978. It has the same legal and academic status as any other national
More informationLEGAL AND TECHNICAL REQUIREMENTS FOR TIME AND FREQUENCY METROLOGY
LEGAL AND TECHNICAL REQUIREMENTS FOR TIME AND FREQUENCY METROLOGY Michael A. Lombardi NIST Time and Frequency Division lombardi@nist.gov Abstract - Who needs time and frequency? This paper answers that
More informationTHE OPEN TRACEABLE TIME PLATFORM AND ITS APPLICATION IN FINANCE AND TELECOMMUNICATIONS. Michael J. Wouters. National Measurement Institute, Australia
THE OPEN TRACEABLE TIME PLATFORM AND ITS APPLICATION IN FINANCE AND TELECOMMUNICATIONS Michael J. Wouters National Measurement Institute, Australia E. Louis Marais National Measurement Institute, Australia
More informationEnhanced Primary Clocks and Time Transfer
Deutsche Telekom Enhanced Primary Clocks and Time Transfer Helmut Imlau ITSF 2017, November 8 th ITSF 2017: Enhanced Primary Clocks and Time Transfer, Deutsche Telekom, Helmut Imlau 1 Agenda (a) Enhanced
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & Z540.3-2006 INSPEC, INC. 7282 Haggerty Rd Canton, MI 48187 Dale Robenault Phone: 734 451 8740 CALIBRATION Valid To: September 30,
More information