Outline. Introduction Laboratory Status Activities Future Plans
|
|
- Griffin Moody
- 6 years ago
- Views:
Transcription
1 Laboratory Report Time and Frequency Metrology Sub Division Research Center for Metrology Indonesian Institute of Sciences RCM LIPI Metrology Enabling Developing Economies in Asia, MEDEA Project for GPS time-transfer and calibration techniques Concluding Workshop October 2017, Yangmei, Taiwan
2 Outline Introduction Laboratory Status Activities Future Plans
3 Outline Introduction Laboratory Status Activities Future Plans
4 Introduction Structure RCM-LIPI Director of RCM-LIPI Administration Division Mechanical Metrology Division Optical Electronic Metrology Division Research Groups Length Metrology Sub Division Electrical Metrology Sub Division Mass Metrology Sub Division Acoustic & Vibration Metrology Sub Division Time & Frequency Metrology Sub Division Temperature Metrology Sub Division Radiometry Photometry Metrology Sub Division
5 Introduction Time and Frequency Sub Divison Time and Frequency Laboratory Responsible for establishing and maintaining units and standards of time & frequency measurement in Indonesia, and for coordinating the national traceability of time &frequency measurement system. Optical Wavelength Laboratory Responsible for establishing and maintaining the optical frequency/wavelength standard, and for coordinating the national traceability of optical frequency/wavelength measurement system. Radio Frequency Laboratory Responsible for establishing and maintaining the unit and standards of radio frequency, and for coordinating the national traceability of radio frequency measurement system.
6 Introduction Members Swivano Agmal Yulita Ika Ratnaningsih A.M.Boynawan Windi Kurnia Syamsuir Asep Hapiddin
7 Outline Introduction Laboratory Status Activities Future Plans
8 Laboratory Status RCM-LIPI operated three commercial cesium clocks 5071A (Cs1, Cs2 and Cs3) Cs1 has been used as source of UTC(KIM) published in Circular T GPS Time Transfer system : TTS-3 GPS/GLONASS regularly send data to BIPM Time Dissemination : NTP server (ntp.metrologi.lipi.go.id up) Cooperation with NICT (ntp2.metrologi.lipi.go.idunder construction) Frequency Calibration : Local frequency standard; general frequency source; counter; period; rise/fall time; pulse width; stopwatch; tachometer; stroboscope.
9 Outline Introduction Laboratory Status Activities Future Plans
10 Activities Campaign UTC(KIM) as Indonesia Standard Time with slogan Satu Nusa Satu Waktu or One Country One Time
11 Activities Continue cooperation with Ministry of Communication and Informatics to issue regulation for electronic time synchronization Cooperation with BMKG(Meteorological, Climatological, and Geophysical Agency) BMKG has cesium clocks need to calibrate BMKG requested to calibrate his clocks using remote time calibration
12 Activities Time dissemination Coordinate with Internet Service Provider and Network Division to provide reliable link for NTP service Current link sharing bandwidth for all internet activities Proposed link all bandwidth for ntp service RCM-LIPI Current link Proposed link ISP Internet client
13 Activities Under Center for Excellent Science program of Ministry of Research, Technology and High Education, we invited Mr. Yi Jiun Huang(TL) on July 10 th 13 th 2017 as instructor for Training Time and Frequency Remote Calibration System
14 Activities Expert Site Visit MEDEA project Visited by Dr. Ichikawa and Mr. Narita (NICT) from August 14 th 18 th 2017
15 Outline Introduction Laboratory Status Activities Future Plans
16 Future Plans Calibrate our TTS3 on G2 lab calibration calibrate BMKG Cesium clock using remote calibration system Propose equipment for supporting remote calibration system practice remote calibration Submit CMC on BIPM appendix C Build reliable NTP server
17 THANK YOU for YOUR ATTENTION A.M. Boynawan
Expert Site Visit Report
Expert Site Visit Report Time and Frequency Metrology Sub Division Research Center for Metrology Indonesian Institute of Sciences RCM LIPI Metrology Enabling Developing Economies in Asia, MEDEA Project
More informationREPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)
Trieu Viet Phuong Deputy head of Time and Frequency Laboratory (TFL) Vietnam Metrology Institute (VMI) N 0 8, Hoang Quoc Viet Road, Caugiay District, Hanoi, Vietnam About Time & Frequency Laboratory (TFL)
More informationREPORT OF TIME AND FREQUENCY LABORATORY (VIETNAM METROLOGY INSTITUTE)
Nguyen Bang Head of Time and Frequency Laboratory (TFL) Vietnam Metrology Institute (VMI) N 0 8, Hoang Quoc Viet Road, Caugiay District, Hanoi, Vietnam About Time & Frequency Laboratory (TFL) Time and
More informationSTATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE)
STATUS REPORT OF TIME AND FREQUENCY LAB. (VIETNAM METROLOGY INSTITUTE) Trieu Viet Phuong Head of Time and Frequency Laboratory, VMI Email: phuongtv@vmi.gov.vn DA NANG 11-2016 About TFL Laboratory of time
More informationTIME & FREQUENCY SERVICES IN MALAYSIA
TIME & FREQUENCY SERVICES IN MALAYSIA Presented by : Mohd Rafiq Bin Abdul Kamal Metrologist National Metrology Laboratory SIRIM Berhad, Malaysia Time & Frequency Laboratory National Metrology Laboratory
More informationMongolian Agency for Standardization and Metrology Time Frequency Lab. Unurbileg Darmaa Head, Length & Time and Frequency lab MASM
Mongolian Agency for Standardization and Metrology Time Frequency Lab Unurbileg Darmaa Head, Length & Time and Frequency lab MASM 2017-10-26 11/13/2017 Mongolian Agency for Standardization and Metrology
More informationNPLI Report. for. Technical workshop and inter-laboratory comparison exercise for GPS time-transfer and calibration techniques under MEDEA
NPLI Report for Technical workshop and inter-laboratory comparison exercise for GPS time-transfer and calibration techniques under MEDEA Dr. V. N. Ojha, Dr. A. Agarwal, Mrs. D. Chaddha, Dr. S. Panja, Dr.
More informationActivity Report of Time and Frequency Laboratory, NMIM (formally known as NML-SIRIM), Malaysia
Activity Report of Time and Frequency Laboratory, NMIM (formally known as NML-SIRIM), Malaysia Dr. Mohd. Nasir Senior Principal Metrologist Ahmad Sahar Senior Metrologist Mohd Rafiq Metrologist Mohd Izzulfitri
More informationDEC Workshop on Participation in Co-ordinated Universal Time
Report (Philippines) DEC Workshop on Participation in Co-ordinated Universal Time 6 7 November 2014 NIM, Beijing, China Sabino Paulo B. Leones, Jr. National Metrology Laboratory (NML) Industrial Technology
More informationTime and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD- Sri Lanka
Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD- Sri Lanka Introduction Measurement Units, Standards and Services Department (MUSSD
More informationTIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY
TIME AND FREQUENCY ACTIVITIES AT THE CSIR NATIONAL METROLOGY LABORATORY E. L. Marais and B. Theron CSIR National Metrology Laboratory PO Box 395, Pretoria, 0001, South Africa Tel: +27 12 841 3013; Fax:
More informationCURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD.
CURRENT ACTIVITIES OF THE NATIONAL STANDARD TIME AND FREQUENCY LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT TELECOM CO., LTD., TAIWAN C. S. Liao, P. C. Chang, and S. S. Chen National Standard
More informationStatus Report on Time and Frequency Activities at National Physical Laboratory India
Status Report on Time and Frequency Activities at National Physical Laboratory India (TCTF 2015) Ashish Agarwal *, S. Panja. P. Arora, P. Thorat, S. De, S. Yadav, P. Kandpal, M. P. Olaniya, S S Rajput,
More informationNMI's Role and Expertise in Synchronization Applications
NMI's Role and Expertise in Synchronization Applications Wen-Hung Tseng National Time and Frequency standard Lab, Telecommunication Laboratories, Chunghwa Telecom Co., Ltd., Taiwan APMP 2014 Time-transfer
More informationUpgradation and Strengthening of National Time Scale of India
Upgradation and Strengthening of National Time Scale of India (ATF 2017) Ashish Agarwal, P. Thorat, M. P. Olaniya, S. Yadav, P. Kandpal, P. Arora, S. Panja, S. De, T. Bharadwaj, N. Sharma, S. Kazim, B.
More informationTraceability measurement results of accurate time and frequency in Bosnia and Herzegovina
INFOTEH-JAHORINA Vol. 11, March 2012. Traceability measurement results of accurate time and frequency in Bosnia and Herzegovina Osman Šibonjić, Vladimir Milojević, Fatima Spahić Institute of Metrology
More informationLITHUANIAN NATIONAL TIME AND FREQUENCY STANDARD
LITHUANIAN NATIONAL TIME AND FREQUENCY STANDARD Rimantas Miškinis Semiconductor Physics Institute A. Goštauto 11, Vilnius 01108, Lithuania Tel/Fax: +370 5 2620194; E-mail: miskinis@pfi.lt Abstract The
More informationTime and Frequency Activities at NICT, Japan
Time and Frequency Activities at NICT, Japan Yasuhiro Koyama, Kuniyasu Imamura, Tsukasa Iwama, Shin'ichi Hama, Jun Amagai, Ryuichi Ichikawa, and Mizuhiko Hosokawa National Institute of Information and
More informationTime and Frequency Laboratory Measurement Units, Standards. (National Metrology Institute) MUSSD-Sri Lanka
Time and Frequency Laboratory Measurement Units, Standards and Services Department (National Metrology Institute) MUSSD-Sri Lanka Introduction Measurement Units, Standards and Services Department (MUSSD
More informationStatus Report on Time and Frequency Activities at CSIR-NPL India
Status Report on Time and Frequency Activities at CSIR-NPL India (APMP -TCTF 2016) S. Panja, A. Agarwal, D. Chadha, P. Arora, P. Thorat, S. De, S. Yadav, P. Kandpal, M. P. Olaniya and V. N. Ojha (Da Nang,
More informationMEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA
COUNTRY REPORT: MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.ANURADHA. PERERA SRI LANKA Government type: Democratic Socialist Republic Location: South Asia,
More informationCRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY
CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TIME AND FREQUENCY METROLOGY Approved By: Chief Executive Officer: Ron Josias Senior Manager: Mpho Phaloane Revised By: Specialist Technical Committee
More information2-5 Frequency Calibration
2-5 Frequency SAITO Haruo, IWAMA Tsukasa, TSUCHIYA Shigeru, and KOYAMA Yasuhiro The Japan Standard Time (JST) and the Coordinated Universal Time (UTC(NICT)), which are constructed by National Institute
More informationTime Comparisons by GPS C/A, GPS P3, GPS L3 and TWSTFT at KRISS
Time Comparisons by GPS C/A, GPS, GPS L3 and at KRISS Sung Hoon Yang, Chang Bok Lee, Young Kyu Lee Division of Optical Metrology Korea Research Institute of Standards and Science Daejeon, Republic of Korea
More informationTHE TIMING ACTIVITIES OF THE NATIONAL TIME AND FREQUENCY STANDARD LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT CO. LTD.
THE TIMING ACTIVITIES OF THE NATIONAL TIME AND FREQUENCY STANDARD LABORATORY OF THE TELECOMMUNICATION LABORATORIES, CHT CO. LTD., TAIWAN P. C. Chang, J. L. Wang, H. T. Lin, S. Y. Lin, W. H. Tseng, C. C.
More informationNov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time. Aimin Zhang National Institute of Metrology (NIM)
Nov.6-7,2014 DEC Workshop on Participation in Coordinated Universal Time Aimin Zhang National Institute of Metrology (NIM) Introduction UTC(NIM) at old campus Setup of new UTC(NIM) Algorithm of UTC(NIM)
More informationInternationally accepted framework for metrology
Internationally accepted framework for metrology Andy Henson BIPM Working Groups The BIPM Bureau International des Poids et Measures the intergovernmental organization through which Member States act together
More informationMEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.A. PERERA
MEASUREMENT UNITS STANDARDS AND SERVICES DEPARTMENT(MUSSD) SRI LANKA PRESENTED BY: R.G.S.A. PERERA SRI LANKA Government type: Democratic Socialist Republic Capital city: Sri Jayawardenapura Location: South
More informationILAC input to CIPM MRA Review Workshop October 2015
ILAC input to CIPM MRA Review Workshop 13-14 October 2015 BIPM Sevres 13 October 2015 By Erik Oehlenschlaeger ILAC (DANAK) ILAC History ILAC first started as a conference in 1977 (Copenhagen) with the
More informationHaruo Saito. National Institute of Information and Communications Technology
Calibration system at NICT Haruo Saito National Institute of Information and Communications Technology Organization of NICT Content Calibration system Calibration system Carried in system and remote system
More informationCIPM and CCPR What are these organizations and how do they affect my testing results. Maria Nadal Photometry, Surface Color and Appearance NIST
CIPM and CCPR What are these organizations and how do they affect my testing results Maria Nadal Photometry, Surface Color and Appearance NIST CIE USA Annual Meeting October 6-7, 2014 Calibration Laboratory
More informationBureau International des Poids et Mesures. International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA
Bureau International des Poids et Mesures International Recognition of NMI Calibration and Measurement Capabilities: The CIPM MRA Prof. Michael Kühne International School of Physics Enrico Fermi Metrology
More informationCCTF 2012 Report on Time & Frequency activities at National Physical Laboratory, India (NPLI)
CCTF 2012 Report on Time & Frequency activities at National Physical Laboratory, India (NPLI) Major activities of the Time & Frequency division of NPLI in the last three years have been: 1. Maintenance
More informationTime and Frequency Research Activity in NIM
Time and Frequency Research Activity in NIM Gao Xiaoxun National Institute of Metrology Bei San Huan Dong Lu No.18 Beijing P.R.China Abstract This paper will introduce scientific research activities in
More informationThe Importance of Global Metrology for Standards, Industry and Trade: Metrology in a Dynamic World
The Importance of Global Metrology for Standards, Industry and Trade: Metrology in a Dynamic World v1 Dr Martin J.T. Milton Director of the BIPM Riyadh and Jeddah 18 and 19 May 2016 The importance of global
More informationComparison of Cesium Fountain Clocks in Europe and Asia
APMP/TCTF workshop 214,Daejeon, Korea Comparison of Cesium Fountain Clocks in Europe and Asia Aimin Zhang National Institute of Metrology(NIM) Sep.2,214 Outline Introduction Setup of PFS comparison Comparison
More informationRapid UTC: a step forward for enhancing GNSS system times Elisa Felicitas Arias
Rapid UTC: a step forward for enhancing GNSS system times Elisa Felicitas Arias Eighth Meeting of the International Committee on Global Navigation Satellite Systems (ICG) Dubai, United Arab Emirates 9-14
More information2-2 Summary and Improvement of Japan Standard Time Generation System
2-2 Summary and Improvement of Japan Standard Time Generation System NAKAGAWA Fumimaru, HANADO Yuko, ITO Hiroyuki, KOTAKE Noboru, KUMAGAI Motohiro, IMAMURA Kuniyasu, and KOYAMA Yasuhiro Japan Standard
More informationBIPM TIME ACTIVITIES UPDATE
BIPM TIME ACTIVITIES UPDATE A. Harmegnies, G. Panfilo, and E. F. Arias 1 International Bureau of Weights and Measures (BIPM) Pavillon de Breteuil F-92312 Sèvres Cedex, France 1 Associated astronomer at
More informationReport of the TC Time and Frequency. Ramiz Hamid TC-TF Chair, TÜBİTAK UME, Turkey
Report of the TC Time and Frequency Ramiz Hamid TC-TF Chair, TÜBİTAK UME, Turkey Contents TC-TF meeting and T&F strategy EMRP Projects and future optical redefinition of the second Time scale generation
More informationTime and Frequency Activities at KRISS
Time and Frequency Activities at KRISS Dai-Hyuk Yu Center for Time and Frequency Metrology, Division of Physical Metrology Korea Research Institute of Standards and Science (KRISS) dhyu@kriss.re.kr Time
More information33 rd Asia Pacific Metrology Programme General Assembly 30 November 1 December 2017 New Delhi, India
33 rd Asia Pacific Metrology Programme General Assembly 30 November 1 December 2017 New Delhi, India Laboratory Report National Metrology Institute of Japan (NMIJ) National Institute of Advanced Industrial
More informationEstablishing Traceability to UTC
White Paper W H I T E P A P E R Establishing Traceability to UTC "Smarter Timing Solutions" This paper will show that the NTP and PTP timestamps from EndRun Technologies Network Time Servers are traceable
More informationDEC Country Report. National Institute of Metrology (Thailand) By Mr.Pairoj Rattanangkul
National Institute of Metrology (Thailand) DEC Country Report By Mr.Pairoj Rattanangkul email : pairoj@nimt.or.th National Institute of Metrology (Thailand) 1 2 Table of Content Brief history of NIMT Where
More informationSTEERING UTC (AOS) AND UTC (PL) BY TA (PL)
STEERING UTC (AOS) AND UTC (PL) BY TA (PL) J. Nawrocki 1, Z. Rau 2, W. Lewandowski 3, M. Małkowski 1, M. Marszalec 2, and D. Nerkowski 2 1 Astrogeodynamical Observatory (AOS), Borowiec, Poland, nawrocki@cbk.poznan.pl
More informationTime and Frequency Activities at NICT, Japan
Time and Frequency Activities at NICT, Japan Yasuhiro Koyama, Kuniyasu Imamura, Tsukasa Iwama, Shin'ichi Hama, Jun Amagai, Ryuichi Ichikawa, Yuko Hanado, and Mizuhiko Hosokawa National Institute of Information
More informationDesignated Institutes participating in the CIPM MRA
Designated Institutes participating in the CIPM MRA Expectations and nomination form Version 1.2 Contents 1. Introduction... 1 2. Designated Institute in Appendix A of the KCDB... 2 2.1. Designation of
More informationStatus Report on Time and Frequency Activities at NPL India
Status Report on Time and Frequency Activities at NPL India (APMP TCTF 2013) A. Sen Gupta, A. Chatterjee, A. K. Suri, A. Agarwal, S. Panja P. Arora, S. De, P. Thorat, S. Yadav, P. Kandpal, M. P. Olaniya
More informationActivity report from NICT
Activity report from NICT APMP 2013 / TCTF meeting 25-26 November, 2013 National Institute of Information and Communications Technology (NICT) Japan 1 1 Activities of our laboratory Atomic Frequency Standards
More informationNational time scale UTC(SU) and GLONASS system time scale: current status and perspectives
State Scientific Center of the Russian Federation National Research Institute for Physical-Technical and Radio Engineering Measurements National time scale UTC(SU) and GLONASS system time scale: current
More informationLaboratory Report National Institute of Information and Communications Technology (NICT), Japan. Section 1: Laboratory Related Matters
32 nd Asia Pacific Metrology Programme General Assembly 17-18 November 2016 Da Nang, Vietnam Laboratory Report National Institute of Information and Communications Technology (NICT), Japan Section 1: Laboratory
More informationFuture challenges in high-frequency electromagnetic metrology (RF to terahertz)
Prof Nick Ridler IEEE Fellow Electromagnetics Science Leader National Physical Laboratory, UK CCEM workshop Future challenges in electrical metrology, BIPM, Paris, 23 March 2017 Focus on three new measurement
More informationRF and Microwave Power Standards: Extending beyond 110 GHz
RF and Microwave Power Standards: Extending beyond 110 GHz John Howes National Physical Laboratory April 2008 We now wish to extend above 110 GHz Why now? Previous indecisions about transmission lines,
More informationSTABILITY AND ACCURACY OF THE REALIZATION OF TIME SCALE IN SINGAPORE
90th Annual Precise Time and Time Interval (PTTI) Meeting STABILITY AND ACCURACY OF THE REALIZATION OF TIME SCALE IN SINGAPORE Dai Zhongning, Chua Hock Ann, and Neo Hoon Singapore Productivity and Standards
More informationDEMETRA A Time Service Demonstrator Patrizia Tavella, INRIM Torino Italy on behalf of DEMETRA consortium
This project has received funding from the European GNSS Agency under the European Union s Horizon 2020 research and innovation programme under grant agreement No 640658. DEMETRA A Time Service Demonstrator
More informationPilot Study EURAMET.AUV.V-P1: Bilateral comparison on magnitude of the complex charge sensitivity of accelerometers from 10 Hz to 10 khz
Pilot Study EURAMET.AUV.V-P1: Bilateral comparison on magnitude of the complex charge sensitivity of accelerometers from 10 Hz to 10 khz 1) Pilot laboratory: Laboratoire national de métrologie et d'essais
More informationTime & Frequency Transfer
Cold Atoms and Molecules & Applications in Metrology 16-21 March 2015, Carthage, Tunisia Time & Frequency Transfer Noël Dimarcq SYRTE Systèmes de Référence Temps-Espace, Paris Thanks to Anne Amy-Klein
More informationActivity report from NICT
Activity report from NICT APMP 2017 / TCTF meeting 27-28 November, 2017 National Institute of Information and Communications Technology (NICT) Japan 1 1 Space time standards laboratory Atomic Frequency
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration Korea 775 Gyeongin-ro
More informationRESULTS FROM TIME TRANSFER EXPERIMENTS BASED ON GLONASS P-CODE MEASUREMENTS FROM RINEX FILES
32nd Annual Precise Time and Time Interval (PTTI) Meeting RESULTS FROM TIME TRANSFER EXPERIMENTS BASED ON GLONASS P-CODE MEASUREMENTS FROM RINEX FILES F. Roosbeek, P. Defraigne, C. Bruyninx Royal Observatory
More informationTwo-Way Time Transfer via Satellites and Optical Fibers. Physikalisch-Technische Bundesanstalt
Two-Way Time Transfer via Satellites and Optical Fibers Dirk Piester Physikalisch-Technische Bundesanstalt Time Dissemination Group (4.42) 42) 1 Outline Two-way satellite time and frequency transfer (TWSTFT)
More information1.Clocks and Time scales
Highlights Activities from July 2009 to August 2012 of the National Time and Frequency Standard laboratory of the Telecommunication Laboratories, CHT Co. Ltd., TAIWAN ABSTRACT Telecommunication Laboratories
More informationEnhanced Primary Clocks and Time Transfer
Deutsche Telekom Enhanced Primary Clocks and Time Transfer Helmut Imlau ITSF 2017, November 8 th ITSF 2017: Enhanced Primary Clocks and Time Transfer, Deutsche Telekom, Helmut Imlau 1 Agenda (a) Enhanced
More informationRemote Frequency Calibration Service at NMIJ
Remote Frequency Calibration Service at NMIJ Case Example for APMP-WS 2014 Frequency Measurement Systems Section National Metrology Institute of Japan (NMIJ), AIST, JAPAN Content Introduction Overview
More informationEnhancing the capability of primary calibration system for shock acceleration in NML
Enhancing the capability of primary calibration system for shock acceleration in NML Jiun-Kai CHEN 1 ; Yen-Jong HUANG 1 1 Center for Measurement Standards, Industrial Technology Research Institute, R.O.C.
More informationTime and Frequency Activities at KRISS
Time and Frequency Activities at KRISS Dai-Hyuk Yu Center for Time and Frequency, Division of Physical Metrology Korea Research Institute of Standards and Science (KRISS) dhyu@kriss.re.kr Time and Frequency
More informationActivity report from NICT
Activity report from NICT APMP 2016 / TCTF meeting 14-15 November, 2016 National Institute of Information and Communications Technology (NICT) Japan 1 1 Space time standards laboratory Atomic Frequency
More information5-3 JJY, The National Standard on Time and Frequency in Japan
5-3 JJY, The National Standard on Time and Frequency in Japan The Communications Research Laboratory (CRL) determines the national standard time and frequency in Japan, which is disseminated throughout
More informationReport. Bilateral Comparison on Time Differences Between Two Pulses Between TÜBİTAK UME and SASO NMCC GULFMET.TF-S1
Report Bilateral Comparison on Time Differences Between Two Pulses Between TÜBİTAK UME and SASO NMCC GULFMET.TF-S1 (Rev. 1) April 21, 2017 Contents Contents... 2 1. Introduction... 3 2. Travelling Standard...
More informationReport of the CCTF WG on TWSTFT. Dirk Piester
Report of the CCTF WG on TWSTFT Dirk Piester Two-way satellite time and frequency transfer (TWSTFT) How does it work? Phase coherent to a local clock pseudo random noise phaseshift keying spread spectrum
More informationINFORMASI LAYANAN KALIBRASI PUSLIT METROLOGI LIPI TAHUN 2018
INFORMASI LAYANAN KALIBRASI PUSLIT METROLOGI LIPI TAHUN 2018 SUBBID: Metrologi Akustik dan Vibrasi No. Nama Alat Spesifikasi/RentangUkur 1 Sound Level Meter, Coupler method - C/A-Weighting at 63 Hz ~ 16kHz
More informationSynchrometrology and PMU Testing at NIST
Synchrometrology and PMU Testing at NIST Jerry FitzPatrick and Tom Nelson National Institute of Standards and Technology i-pcgrid Workshop 2013 March 27, 2013 2 Topics for Today NIST Mission SGIP NIST
More informationCALIBRATION OF THE BEV GPS RECEIVER BY USING TWSTFT
CALIBRATION OF THE BEV GPS RECEIVER BY USING TWSTFT A. Niessner 1, W. Mache 1, B. Blanzano, O. Koudelka, J. Becker 3, D. Piester 3, Z. Jiang 4, and F. Arias 4 1 Bundesamt für Eich- und Vermessungswesen,
More informationPendulum Instruments AB Sorterargatan 26 SE VÄLLINGBY SWEDEN
à Pendulum Instruments AB Sorterargatan 26 SE-162 15 VÄLLINGBY SWEDEN Handläggare, enhet / +DQGOHGÃE\ÃGHSDUWPHQW Datum / 'DWH Beteckning / 5HIHUHQFH Sida / 3DJH Kenneth Jaldehag, Fysik och Elteknik 2000-09-04
More informationWide-Area Time Distribution with PTP Using Commercial Telecom Optical Fiber
Wide-Area Time Distribution with Using Commercial Telecom Optical Fiber NASPI Work Group Meeting March 22, 2017 Lee Cosart, lee.cosart@microsemi.com Microsemi Corporation Presenter, Co-author Marc Weiss,
More informationFederal Department of Justice and Police FDJP Federal Office of Metrology METAS. Measurement Report No
Federal epartment of Justice olice FJP Federal Office of Metrology METAS Measurement Report No 9-0009 Object GPS receiver type Septentrio PolaRxeTR serial 05 Antenna type Aero AT-775 serial 5577 Cable
More informationProgramme of work and budget for Plans for Time Department
Programme of work and budget for 2013-2015 Plans for 2016-2019 Time Department Elisa Felicitas Arias 101 th Meeting of the CIPM, Session 1 BIPM, Sèvres, 8 June 2012 Programme of work 2013-2015 Continues
More informationCertificate of Calibration No
Federal Department of Justice olice FDJP Federal Office of Metrology METAS Certificate of Calibration No 7-006 Object GPS rcvr type Septentrio PolaRx4TR PRO serial 005 Antenna type Aero AT-675 serial 500
More informationJoint ILAC CIPM Communication regarding the. Accreditation of Calibration and Measurement Services. of National Metrology Institutes.
Joint ILAC CIPM Communication regarding the Accreditation of Calibration and Measurement Services of National Metrology Institutes 7 March 2012 Authorship This document was prepared by the International
More informationSMD ENS Metrology - National Standards. Short overview. Hugo Pirée. World Metrology Day 2018 Brussels.
SMD ENS Metrology - National Standards Short overview Hugo Pirée World Metrology Day 2018 Brussels Federal government FPS ECONOMY Gen. Direction QUALITY & SAFETY Division METROLOGY 14 persons National
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Micro Precision Calibration Pte. Ltd. Blk
More informationGFT Channel Digital Delay Generator
Features 20 independent delay Channels 100 ps resolution 25 ps rms jitter 10 second range Output pulse up to 6 V/50 Ω Independent trigger for every channel Four triggers Three are repetitive from three
More informationThe Physikalisch-Technische Bundesanstalt,
Physikalisch-Technische Bundesanstalt the National Metrology Institute of Germany The Physikalisch-Technische Bundesanstalt, Germany snational metrologyinstitute, isa scientific and technical higher federal
More informationTraceability in Time and Frequency Metrology
Traceability in Time and Frequency Metrology Michael A. Lombardi National Institute of Standards and Technology Time and Frequency Division 325 Broadway Boulder, CO 80303 United States of America (303)
More informationAn Experiment Study for Time Synchronization Utilizing USRP and GNU Radio
GNU Radio Conference 2017, September 11-15th, San Diego, USA An Experiment Study for Time Synchronization Utilizing USRP and GNU Radio Won Jae Yoo, Kwang Ho Choi, JoonHoo Lim, La Woo Kim, Hyoungmin So
More informationOUR HISTORY OUR MISSION OUR ACTIVITIES
Company Profile OUR HISTORY Established in 1953, the Industrial Research Institute (IRI) is registered as a Lebanese nonprofit institution declared of public utility by D/L n 10059 dated 17 August 1955,
More informationCALIBRATION OF THE BEV GPS RECEIVER BY USING TWSTFT
CALIBRATION OF THE BEV GPS RECEIVER BY USING TWSTFT A. Niessner 1, W. Mache 1, B. Blanzano, O. Koudelka, J. Becker 3, D. Piester 3, Z. Jiang 4, and F. Arias 4 1 Bundesamt für Eich- und Vermessungswesen,
More informationCalibration schedule 2016/9/29
Outline Time links calibration Equipment calibration NIM calibrator: Equipment, characteristics NIM calibrator: Operation Calibration campaign: Data and results 51 Calibration schedule 52 NTSC calibration
More informationResearch Article Fast Comparison of High-Precision Time Scales Using GNSS Receivers
Hindawi International Navigation and Observation Volume 2017, Article ID 9176174, 4 pages https://doi.org/10.1155/2017/9176174 Research Article Fast Comparison of High-Precision Time Scales Using Receivers
More informationTiming-oriented Processing of Geodetic GPS Data using a Precise Point Positioning (PPP) Approach
6 th Meeting of Representatives of Laboratories Contributing to TAI BIPM, 31 March 2004 Timing-oriented Processing of Geodetic GPS Data using a Precise Point Positioning (PPP) Approach Patrizia TAVELLA,
More informationITSF 2017 It is time for time It Is Time For Time PTP/NTP/IRIG Time Server w/ RFC3161 TimeStamping
Tomasz Widomski It Is Time For Time From ultra precision sub-nanosecond synchronization until Trusted time distribution systems with audit and verification facilities Building Robust Synchronization Systems
More informationReport to the 20th Meeting of CCTF Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST
Report to the 20th Meeting of CCTF Research Activities on Time and Frequency National Metrology Institute of Japan (NMIJ)/AIST The National Metrology Institute of Japan (NMIJ) is responsible for almost
More informationEvaluation of timing GPS receivers for industrial applications
12th IMEKO TC1 Workshop on Technical Diagnostics June 6-7, 213, Florence, Italy Evaluation of timing GPS receivers for industrial applications Vojt ch Vigner 1, Jaroslav Rozto il 2, Blanka emusová 3 1,
More information5-2 Generating and Measurement System for Japan Standard Time
5-2 Generating and Measurement System for Japan Standard Time HANADO Yuko, IMAE Michito, KURIHARA Noriyuki, HOSOKAWA Mizuhiko, AIDA Masanori, IMAMURA Kuniyasu, KOTAKE Noboru, ITO Hiroyuki, SUZUYAMA Tomonari,
More informationAcoustic Calibration Service in Automobile Field at NIM, China
Acoustic Calibration Service in Automobile Field at NIM, China ZHONG Bo National Institute of Metrology, China zhongbo@nim.ac.cn Contents 1 Overview of Calibration Services 2 Anechoic Room Calibration
More informationTime and Frequency Transmission Facilities
Time and Transmission Facilities Ohtakadoya-yama LF Standard Time and Transmission Station Disseminating accurate Japan Standard Time (JST)! Time synchronization of radio clocks Time standard for broadcasting
More informationContinuous development of the national standard for vibration
Continuous development of the national standard for vibration by Ian Veldman, National Metrology Laboratory, CSIR In this fast technologically-advancing world, higher measurement accuracy is part of the
More informationActivity report from NICT
Activity report from NICT APMP 2015 / TCTF meeting 2-3 November, 2015 National Institute of Information and Communications Technology (NICT) Japan 1 1 Space time standards laboratory Atomic Frequency Standards
More informationPROMOTING QUALITY AND STANDARDS
PROMOTING QUALITY AND STANDARDS 1 PROMOTING QUALITY AND STANDARDS Strengthen capacities of national and regional quality systems (i.e. metrology, standardization and accreditation) Build conformity assessment
More informationRECENT ACTIVITIES IN THE FIELD OF TIME AND FREQUENCY IN POLAND
RECENT ACTIVITIES IN THE FIELD OF TIME AND FREQUENCY IN POLAND Jerzy Nawrocki Astrogeodynamical Observatory, Borowiec near Poznań, and Central Office of Measures, Warsaw, Poland Abstract The work of main
More information