IQ241/242 Controllers

Size: px
Start display at page:

Download "IQ241/242 Controllers"

Transcription

1 Q/ Controllers Q/ CONTROLLERS Description Features The Q/ controllers are of medium capacity designed for the control of all types of building plant. They can provide a minimum of digital inputs, and analogue voltage outputs. A further 0 /O points can be made available by using up to 0 S cards, each providing inputs or outputs of the same type ( input only, input or output). The Q has thermistor inputs pre-fitted via S cards. S cards can provide analogue current, analogue voltage, thermistor, or digital inputs, or analogue voltage outputs giving the Q/ sufficient capability for more complex strategies. t can operate either as a stand alone device or as part of a Building Management System. f required a Network Display Panel can be mounted on the front cover, or externally, using a node controller fitted into the Q/. A standard Display Panel can also be mounted on the front cover, or externally. The Q/ also has the facility to connect any Trend supervisor or Engineering Tool to the network without a separate node controller. Physical 30 Vac Power connector second cycle time. Optional integral/external Network Display Panel. Optional integral/external Display Panel. Access to entire network via local supervisor connection. Facility for mounting an additional node controller. High capacity DDC with PD control loops. Stand alone or integrated system operation. digital inputs. analogue voltage outputs. 0 slots for S cards (0 /O points) (Q has cards pre-fitted) Optional cable management system. Knockouts for M0 cable gland Knockout for RDS connector Knockout for additional node RS3 mm Q/ V Power connector S card fittings under flap 3 mm /O LEDs 3 LEDs Channel identification label Network connectors d ig ita l in p u ts 7 9 LAN 3 TX V RX 0 3 S 3 a n a lo g u e in p u ts S S L S L a n a lo g u e o u tp u ts L C 3 C C 7 C 9 C C 3 C C 7 C 9 C C 3 C C 7 C 9 C 3 C 33 C 3 C 37 C 39 C C C C C 0 C C C C C 0 C C C C C 30 C 3 C 3 C 3 C 3 C 0 C L AUX v Supervisor port /O connectors Earthing bar 3 mm Q/ Controllers TA0303 ssue /D /0/03 Auxiliary supply

2 Q/ PHYSCAL (Continued) Cable Management System mm 0 mm 3 mm 0mm holes for cable entry/exit (suitable for standard M0 (copex type) conduit glands) FUNCTONALTY The Q/ Controller s functionality can be divided into two sections, the strategy, and the hardware. STRATEGY The strategy processes inputs according to a set of instructions and then outputs signals which can be used to control plant. Configuration: The Q/ uses the standard Q configuration mode which enables configuration via the network, or by direct connection. Alternatively SET (System Engineering Tool) can be used to create an.qf strategy data file which can then be downloaded to the controller. SET can also be used to upload, and download.qf files for backup purposes. Modules: The strategy consists of a number of individual functional blocks known as configuration modules. These blocks can be linked in various combinations to enable plant to be controlled appropriate to the building s requirements. The table lists the different types of configuration modules and the number of each type available with Q/. Module Type Number Module Type Number Sensor Critical Alarm Sensor type Alarm History 0 Loop 3 C Comms Function 0 Digital nputs Logic 0 Fast Sequence Driver 3 Zone Knob 30 Schedule 3 Switch 0 Calendar 0 Sensor log 3 User Password Sequence step 00 Sequence time s Analogue Nodes Digital Nodes 0 Display 00 Directory 0 Page 0 Group 0 Route 0 Destination 7 New Alarm Log 00 Full details of the modules are given in the Q Configuration Manual and Addendum. The Q/ contains the normal Q features as described in Q Configuration Manual Addendum: Engineers Journal (J), /O Summary (i/o), Loader ssue (R(c), c lower case), Serial Number (R(s), s lower case), Supply Frequency Option, Enhanced Logging, Module position, and Strategy Cleardown. /O Channel reference: The Q/ has very flexible /O which can be configured in a number of ways. The configuration input modules (sensors and digital inputs) and the output modules (drivers) are related to the external channels as shown in the table below. The external channel reference for these modules is displayed in configuration mode. Module type Module reference External channel Sensor-analogue input S to S0 3 to 3 Sensor-digital input S t o S 3 ( n o t normally used*) to 3 Digital input to 3 to 3 Driver Driver channel to driver channel 0 0 to The table below specifies the possible modes for each channel. Module nput Modes S to S0 analogue input, digital input*, internal analogue, internal digital S to S3 digital input*, internal analogue, internal digital S33 to S internal analogue, internal digital to 3 digital input 33 to internal digital Note that as sensors and digital inputs are supported separately on the display panel, and have separate labels, use of sensor modules in digital input mode is not normally required. FRMWARE Communications: When operating as part of a Building Management System, the Q/ will be connected to other devices via the Trend Network. This means that information within the Q/ can be accessed using one of the Trend supervisor programs, or passed to other Trend Q controllers using inter-controller communications, enabling the sharing of information across the whole system. When connected to the network the controller can use up to 3 different addresses. One address is for the controller itself, the second and third are optional, and are for the Network Display Panel, and locally connected supervisor. This means that both the Network Display Panel and supervisor have their own network addresses when connected to the network via the controller. The controller s address is set by a switch on the module, and the addresses for the network display panel, and supervisor are software selectable. Q/ Controllers TA0303 ssue /D /0/03

3 ! # % ' " $ & : :! # % '! # % '! " $ & " $ &!! ) +! + # + % + ' + +! + # + % + ' + +! + # + % + ' +! +!! +! # +! % +! ' + " L ) 7 : + " + $ + & " + $ + & " + $ + & +! +! +! " +! $ +! & + " +!!! #! %! '! "! $! & " Q/ HARDWARE Unit: The Q/ is supplied in a metal and plastic enclosure which provides P0 protection for the unit. The controller can be fitted with an optional cable management system. Cable management system: The cable management system comprises of a metal box with 7 off 0 mm metal knockouts ( rear, bottom, each side). The knockouts can be removed to provide cable entry/exit holes suitable for grommets, or standard M0 (copex type) conduit glands. t fits immediately underneath the controller, or the relay extension system (if fitted) using a simple hooking method preventing accidental contact with the terminals. The diagram below illustrates how a cable management system can be fitted to an Q/ 3 " Q/ with Cable Management System Network: The network terminals facilitate connection of or wire cables. The address and baud rate (9k, 9k, or k) are selected by switches. The standard Trend node features are included (TX RX, and network OK indicators, bypass relay, and network alarm generation). There is also the facility for connection of a Network Display Panel, and/or supervisor to the network via the controller without the need for additional node controllers. A location is also provided for mounting an extra node controller, e.g. TMN, should this be required. Address/Baud rate switch: The address on the Lan is set by poles to 7 in range, to 9, to 9 and must be unique on the Lan. The baud rate is set by poles to 0 in the range k, 9k, 9k and must match the other nodes on the Lan. The address/baud rate switch may also be used to perform a strategy cleardown; this is done by setting all the address/baud rate poles to zero before power up (see nstallation nstructions, TG033 sheet and Q Configuration Manual Addendum). For this reason the address should normally be set non-zero. ndicators: LED indicators for receive and transmit network current flow (RX, TX) and network OK ( ), also for power ( ), all /O channels ( ), and watchdog ( ). See specification section for details. Connectors: Two part connectors are used throughout to facilitate wiring. The 30 Vac power supply uses a standard EC connector. An earthing bar is provided for screen termination. Power: 30 Vac 0/0 Hz, Vac 0/0 Hz or Vdc. V supply must be isolated. Fusing: The controller has no replaceable fuses; protection is provided by means of a self resetting thermally protected transformer. The Vac or dc versions have a solid state multifuse. Note that a switch of circuit breaker must be included in the supply to the unit and in close proximity to it, and must be clearly marked as the disconnecting device for the unit. The /O modules are also individually protected against short circuits. Battery Backup: Details about the strategy configuration, time and date, and logged data are stored in RAM. A plug-in lithium cell provides power to maintain the data in the event of power failure, or the controller being switched off. S Cards: S Cards enable the Q configuration of the controller to be set up according to user requirements. Each card provides input/output channels of the same type and is supplied complete with terminals. The range of S Cards provides analogue current, analogue voltage, thermistor, and digital inputs, or analogue voltage outputs. The Q/ has space for 0 S Cards providing up to 0 additional /O channels ( input only, input or output). The Q has thermistor inputs pre-fitted via S cards. Auxiliary Supplies: The Q/ has two types of auxiliary supply which share 000 ma. Both are thermally protected and can supply Vdc at a maximum of 00 ma. The first is a single connector for relay modules, sensors external NDP, external DP etc. The second consists of 0 connectors for relay modules etc. connected to channels to 0. The 000 ma will normally be available, but if the Q/ has an integral NDP or an integral node controller fitted, only 900 ma would be available to be shared between the two supplies. Displays: The Q/ can be fitted with 3 different types of display, a -line Display Panel, a Network Display Panel, and a PC. The Q/ has ports, the local supervisor port on the front panel (RJ) and the NDP port under the cover on the main board. These correspond to the two extra CNC addresses provided by the Q/; the local supervisor port address, and the NDP port address. NDP V supply (NDP PWR) NDP Port (NDP) local supervisor port (RJ) -line Display Panel: The controller may be purchased with a DP option fitted in the cover or there is a retrofit kit (KT/DP) to add an integral DP. Alternatively an external DP (i.e. HDP, FPK, ENCLS/FP) may be connected by fitting the KT/xx/RDS option which provides a way D type female connector on the upper face of the unit. f a display panel is mounted in the front cover, it will not be possible to connect an external -line display or mount an internal Network Display Panel. The DP provides access to parameters within the controller. Fitting an external DP will reduce available Vdc auxiliary current by 30 ma (see Auxiliary Supply section). Q/ Controllers TA0303 ssue /D /0/03 3

4 ) * +,! # % ' " $ & : :! # % '! # % '! " $ & " $ &!! ) +! + # + % + ' + +! + # + % + ' + +! + # + % + ' +! +!! +! # +! % +! ' + " L ) 7 : + " + $ + & " + $ + & " + $ + & +! +! +! " +! $ +! & + " +,!!! #! %! '! "! $! & ",! # % ' " $ & : :,! # % '! # % '! " $ & " $ &!! ) +! + # + % + ' + +! + # + % + ' + +! + # + % + ' +! +!! +! # +! % +! ' + " L ) 7 : + " + $ + & " + $ + & " + $ + & +! +! +! " +! $ +! & + " + ) * +,,!!! #! %! '! "! $! & ",! # % ' " $ & : :! # % '! # % '! " $ & " $ &!! ) +! + # + % + ' + +! + # + % + ' + +! + # + % + ' +! +!! +! # +! % +! ' + " L ) 7 : + " + $ + & " + $ + & " + $ + & +! +! +! " +! $ +! & + " + ) * +,,!!! #! %! '! "! $! & ", Q/ HARDWARE (continued) PC: A computer running a Trend Supervisor or Engineering Tool can be connected to the Trend network via the controller s supervisor port without the need for an additional node controller although it does have its own network address. When connected in this way the supervisor will have access to all devices on the network, and will function as if it were connected via its own node controller. A wall mounting display, room display (RD), or smart display unit (SDU) may be connected to the local supervisor port. Both displays monitor and adjust parameters in the local Q/ only. The RD enables temperature setpoint display and adjustment with options for occupancy override and fan speed adjustment (see order codes section). The SDU enables monitor and adjustment of selected parameters. f a supervisor/engineering tool, RD or SDU is connected to the controller it is not possible to connect an external NDP. Network Display Panel: A Network Display panel can be mounted externally or in the front cover to provide access to parameters within all Q controllers on a single or multi-lan system. Using icons, and softkeys it allows an operator to perform, under password protection, supervisory functions, such as setpoint adjustments, or to view logs and alarms from all controllers on the system. t can be powered from the Q/. The controller may be purchased with an NDP option fitted in the cover or there is a retrofit kit (KT/ENDP/) to add an integral NDP. Connection is via the internal NDP port (when mounted in front cover), or the supervisor port (when mounted externally). f mounted in the front cover, it is not possible to mount an internal Display Panel, and if the supervisor port is used to connect the NDP it is not possible to connect a Supervisor/Engineering Tool. t uses 7 ma from the Vdc supply (see auxiliary supply section above). f an NDP is connected externally, the CABLE/ EJ009 should be used to connect both the signal (RJ) and power (AUX). Note that if the NDP is connected externally via the local supervisor port (RJ) it uses the local supervisor port address (not NDP port address). The diagrams below illustrate the various combinations in which the display panels, network display panels and supervisor/engineering tools can be connected. FPK or HDP FPK or HDP (connected via DP port if (connected via DP port if KT/xx/RDS fitted) KT/xx/RDS fitted) 3 " 3 " 3 " ntegral DP ntegral NDP PC, NDP, RD or SDU (connected via Supervisor port) PC, NDP, RD or SDU (connected via Supervisor port) PC, NDP, RD or SDU (connected via Supervisor port) nputs/outputs: The Q and Q both have digital inputs and analogue voltage outputs, in addition the Q has thermistor inputs provided by pre-fitted S cards (SCT). The maximum number of additional channels provided via S Cards ( per S card) is 0 for Q and for Q. Qx Digital nputs Thermistor Q 0 ) Q ) S cards ( channels per card) : analogue current inputs (SCC) analogue voltage inputs (SCV) analogue thermistor inputs (SCT) digital inputs (SCD) analogue voltage outputs (SCVO) Additional S card channels Analogue Voltage Outputs Additional S card channels Max No. of additional S cards which can be fitted 0 (0 S cards ( S cards) 0 ( S cards ( S cards) Q/ Controllers TA0303 ssue /D /0/03

5 Q/ HARDWARE (continued) channel identification label!!!!! " # $ % & ' " # $ % & '! " # $ % & '!!! "! #! $! %! &! '!! EC EJ= E F K J = = C K A E F K J & ' # ' = = C K A K JF K J & Fitted on Q Built in digital inputs nput only S cards nput or Output S cards Built in voltage outputs External reference Channel Digital nput Sensor Driver Output channel C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C S S S S S S S S S S S S S S S S S S S S L L L L L L L L L L L L L L L L L L L L Note sensors start at channel 3 +! + # + % + ' + +! + # + % + ' + +! + # + % + ' +! +!! +! # +! % +! ' + + " + $ + & " + $ + & " + $ + & +! +! +! " +! $ +! & + " + Digital nputs (channels to fitted - channels 3 to 3 optional via S cards - SCD) ( to 3 correspond to channels to 3) Nn K 39K Channels 3 to 0 prefitted with thermistor inputs on Q yellow C Analogue Current nputs (channels 3 to 3 optional via S cards - SCC) (S to S0 correspond to channels 3 to 3) 00K Nn 0R Channels 3 to 0 prefitted with thermistor inputs on Q C + V LOOP EXT LOOP EXT Analogue Voltage nputs (channels 3 to 3 optional via S cards - SCV) (S to S0 correspond to channels 3 to 3) Nn 00K 00K Channels 3 to 0 prefitted with thermistor inputs on Q C Analogue Thermister nputs (channels 3 to 3 optional via S cards - SCT) (S to S0 correspond to channels 3 to 3) + V 0K 00K Channels 3 to 0 prefitted with thermistor inputs on Q Nn C Q/ Controllers TA0303 ssue /D /0/03

6 Q/ HARDWARE (continued) Analogue Voltage Outputs (channels 33 to 0 fitted - channels to 3 optional via S cards - SCVO) (Driver output channels to 0 correspond to channels 0 to i.e. reverse order) V R yellow 00R OUTn C K7 ntegral Node: f required an additional node controller (e.g. TMNH, TNME, CNC, PNC, NC, LNC/FTT) may be fitted inside the Q/ using the node fixing kit, KT/NODE/Q. The fixing kit contains nylon pillars which are screwed to the holes in the Q/. The node card has holes that fit onto the pillars enabling the node to be screwed into position. There is a special Vdc supply connection (labelled XNC/PWR) and a network connector (labelled XNC). The two on-board network links must be removed to enable the network to connect to the node. hinged plate Note that an additional node controller will consume current from the Vdc auxiliary supply; see auxiliary supply section above and appropriate node controller data sheet. There is a top panel Way D-type knockout for RS3 to auxiliary node and two circular M0 knockouts for other auxiliary node cables. network links node network connection (XNC) node supply (XNC PWR) Q/ Controllers TA0303 ssue /D /0/03

7 Q/ COMPATBLTY Supervisors: 9x series, 9, NDP (v.3 or greater), 9, 93, Viewpoint+, 9. Utility software: PowerTool, +/Toolbox version, Strategy Browser, Change Tracker, SET, Wupdn. Controllers: t can communicate to other Trend Q controllers using inter controller communications. nterface: Local Display: t can be connected to Trend interface modules. Check interface module specification to ensure compatibility. Network Display Panel, -line Display Panel. The Q Configuration Reference Manual Addendum covers the compatibility between different types of strategy files, and between the Q/ sensor logs, and supervisors and software tools. Q/ Controllers TA0303 ssue /D /0/03 7

8 Q/ NSTALLATON The Q/ controller must be installed on a flat surface such as, a wall, or panel, using screws and washers. The procedure involves: mount the controller in position fit cable management tray if required route the cable to the controller connect power connect the /O connect the auxiliary supply connect network set network address and baud rate fit S cards if required switch on configure the strategy check operation The installation procedure is covered in the Q/ nstallation nstructions (TG030, sections and.). Sections.,.3, 3., 3., 3.3, 3. cover Connecting to a PC, Connecting to NDP, Replacing the Battery, Zero Address/Baud Rate Reset, Mounting in an Enclosure (ENCLS), Connecting a remote -line Display. Other installation instructions: Post fitting an integral NDP, KT/ENDP/ nstallation nstructions, TG0. Post fitting an integral -line Display Panel, KT/DP nstallation nstructions, TG0373. Fitting an integral node, KT/NODE/Q nstallation nstructions, TG007. Fitting an external NDP or ENCLS/FNDP, NDP nstallation nstructions, TG00. Fitting Remote Display Panel Support, KT/xx/RDS nstallation nstructions, TG03. Fitting Cable Management Tray, ENCLS/CMTRAY/ nstallation nstructions, TG0330. Fitting S Cards, SCVO, SCV, SCC, SCT, SCD, S Cards nstallation nstructions, TG037 Q/ Controllers TA0303 ssue /D /0/03

9 TX RX! " # $ % & '! " # $ % & '! " # $ % & '!!!!! "! #! $! %! &! ' EC EJ= E F K J! = = C K A E F K J & ' ' & = = C K A K JF K J Q/ CONNECTONS V Supply (option) part Mat-N-Loc connector Vac: Vac Earth Yellow Green Blue EC connector Auxiliary Supplies off part connectors with screw terminals for 0. to. mm cross section area cable. Supervisor Port v AUX " LoadLoad off RJ (FCC) V supply must be isolated! # % ' " $ &! # % '! # % '! " $ & " $ &!!!!! #! %! '! "! $! & " channel identification label LAN C 3 C C 7 C 9 C C 3 C C 7 C 9 C C 3 C C 7 C 9 C 3 C 33 C 3 C 37 C 39 C v AUX C C C C 0 C C C C C 0 C C C C C 30 C 3 C 3 C 3 C 3 C 0 C !! # Network off part connectors with screw terminals for 0. to. mm cross section area cable. Using two wire method Using four wire method LAN 30 Vac Supply (option) LAN T- T+ OUT Earthing bar N R+ R- T- T+ R- R+ OUT Earthing bar N R+ R- T+ T- /O channel identification label!!!!! " # $ % & ' " # $ % & '! " # $ % & '!!! "! #! $! %! &! '!! EC EJ= E F K J = = C K A E F K J & ' # ' = = C K A K JF K J & Fitted on Q Built in digital inputs nput only S cards nput or Output S cards Built in voltage outputs External reference Channel Digital nput Sensor Driver Output channel C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C S S S S S S S S S S S S S S S S S S S S L L L L L L L L L L L L L L L L L L L L Note sensors start at channel 3 +! + # + % + ' + +! + # + % + ' + +! + # + % + ' +! +!! +! # +! % +! ' + + " + $ + & " + $ + & " + $ + & +! +! +! " +! $ +! & + " + Q has channels 3 to 0 pre-fitted with thermistor input S cards; otherwise channels 3 to 3 require S cards fitted in order to function Q/ Controllers TA0303 ssue /D /0/03 9

10 Q/ FELD MANTENANCE The Q/ controller requires virtually no routine maintenance, however it is recommended that the lithium battery be replaced every years, as explained in the nstallation nstructions (TG030, sheet 3). ORDER CODES Q/[Display]/[Node]/[PSU] Q/[Display]/[Node]/[PSU] : digital inputs, analogue voltage outputs, and 0 configurable channels : digital inputs, thermistor inputs, analogue voltage outputs, and configurable channels B lank No display. ENDP Q/ with front cover. DP Q/ with cover. [ Display] [ Node] [PSU] Network Display Panel in -line Display Panel in front blank TMNH TMNE CNC PNC NC LNC/FTT No node Vac power supply Node including integral MODEM Node for external MODEM Node for Trend network Node for remote printer Node for Trend nternetwork Node for LonWorks network VAC Vac power supply VDC Vdc power supply e.g. Qx/ENDP/TMNH/30 Specifies an unboxed Q/ with integral NDP, integral modem, and 30 Vac power supply. S cards Q (0 input cards max, output cards max, 0 cards in total max). Q ( input cards max, output cards max, cards in total max). Note that S cards are supplied with terminals. SCVO Analogue voltage outputs S card SCV Analogue voltage inputs S card SCC Current inputs S card SCT Thermistor inputs S card SCD Digital inputs S card Cable management system ENCLS/CMtray/ CABLE/EJ0 CABLE/EJ009 cable management tray and cover (only may be fitted to a single Q/) Adapter cable RJ to 9 way D type female for local PC connector Adapter cable RJ to 9 way D type female and screw terminals for external NDP connection Retrofit kits KT/ENDP/Q KT/DP KT/xx/RDS KT/node/Q Kit to retrofit Network Display Panel in front cover (does not include NDP) Kit to retrofit -line Display Panel, HDP, FPK to front cover of Qx, Q3x, Q/, Q0 (does not include -line display panel) Kit to enable connection of -line Display (FPK or HDP) externally (does not include line-display panel) Kit for fitting additional integral node (does not include node) Enclosures ENCLS ENCLS/FP ENCLS/NDP 00 mm x 00 mm x 0 mm P enclosure (does not include NDP) 00 mm x 00 mm x 0 mm P enclosure with -line Display Panel on front 00 mm x 00 mm x 0 mm P enclosure with Network Display Panel on front Other Displays SDU/Q RD/Q/K RD/Q/KOS RD/Q/KOSF Smart Display Unit for wall mounting enabling monitoring and adjustment of parameters Room Display for wall mounting, including temperature, setpoint display and adjustment Room Display for wall mounting, including temperature, setpoint display and adjustment, and occupancy override Room Display for wall mounting, including temperature, setpoint display and adjustment, occupancy override, and fan speed adjustment 0 Q/ Controllers TA0303 ssue /D /0/03

11 Q/ SPECFCATONS CONTROLLER Electrical CPU :33 3 bit micro controller CPU speed :.7 MHz Cycle time : s Memory : kbyte battery backed SRAM, and kbyte Flash. Supply voltage /30 :30 Vac + -0 %, 0 to 0 Hz /VAC : Vac + -0 %, 0 to 0 Hz (Vac supply must be isolated). /VDC : Vdc +% -0% ( V to 3 Vdc) Auxiliary supply : Vdc, 000 ma dependent on configuration, see page for further details. Consumption :0 VA max Fusing :No replaceable fuses required. All protection self resetting. Battery backup :Battery maintains time, and logged data with mains off for at least years. Battery :Saft LM0, 3 V, or equivalent Clock accuracy :30 s per month (typical). Network display panel :con driven display panel with backlit display, for use on single or multi Lan systems. Can be mounted in front cover, or externally. Display panel : x 0 character display, with programmable softkeys. Can be mounted in front cover, or externally via display panel connector. Network :0 ma serial wire current loop, opto isolated, polarity independent receiver, balanced transmitter. Supervisor transmission :RS3, EA/TA/3E, V Distance Supervisor : m Network :Dependent on cable type, see table below. Cable Belden 9 Belden 907 Trend TP////HF/00 (Belden 7) Trend TP////HF/00 (Belden 73) k baud 9k baud 9k baud No. of Wires 000 m 000 m 700 m 000 m 000 m 00 m 000 m 700 m 30 m 000 m 00 m 0 m Baud rate Network :Selectable by switch k, 9k, or 9k, set to be same as other nodes on Lan. NDP :9k. Supervisor :9k. Network addresses Controller Supervisor port NDP port :Selectable by switch, nodes addressable (, to 9 excluding 0) set to be unique on Lan. :Software selectable, nodes addressable (, to 9 excluding 0) set to be unique on Lan. :Software selectable, nodes addressable (, to 9 excluding 0) set to be unique on Lan. nputs/outputs Signal Cable Channels to :Analogue voltage, Current, Thermistor, or Digital inputs, and Analogue voltage outputs. Trend TP////HF/00 recommended (Belden 7) digital inputs. nternally, or self powered volt free contact. Wetting current Vdc, count rate 3 Hz max. Status LED per channel. ON if input is closed. Channels 3 to 0 Q: universal inputs, slots to fit Trend analogue voltage input, current input, thermistor input, or digital input S cards. Q: thermistor inputs (via slots pre-fitted with S cards). Channels to 3 universal /O, slots to fit Trend analogue voltage input, current input, thermistor input, digital input, or analogue voltage output S cards. Channels 33 to 0 analogue voltage outputs. bit resolution ( steps). 0 to 0 V with 0 ma current limit, accuracy ±00 mv equivalent to ± % span. Status LED per channel. Light intensity increases with output voltage. Mechanical Dimensions :3 mm x 3 mm x mm Material Chassis :Steel Cover :Fire retardant ABS Protection :P0 Weight :. kg Connectors /30 :EC plug / :Mat-N-Loc part connector Network : part connector with screw terminals for 0. to. mm cross section area cable. /O : part connector with screw terminals for 0. to. mm cross section area cable. Supervisor port :RJ (FCC), for Trend utility software connected via adaptor cable CABLE/EJ0. Display panel way D type (if KT/RDS fitted). Environmental EMC Emissions :EN00-. mmunity :EN00-. Safety :EN00. Ambient limits storage :-0 C to 0 C operating :0 C to C humidity :0 to 90 %RH non-condensing Protection :P0 (with CMtray fitted) ndicator Lamps TX RX PWR WD LAN :(green) ON when power supply is connected. :(red) ON if controller has a software fault. :(green) ON if network is operating. Flashes if prohibited address set (0,, 3, >9). :(yellow) ON if current is flowing from the network transmitter. :(yellow) ON if current is entering the network receiver. Q/ Controllers TA0303 ssue /D /0/03

12 Q/ SPECFCATONS (continued) Version Firmware Board SCVO card nput S Card :v3 or greater :AM070 v :AM070 v :AM0777 v S CARDS Dimensions :3 mm x mm x 0 mm Analogue voltage input card Analogue voltage inputs : channels per card, bit resolution (09 steps). Minimum 0 db series mode rejection at supply frequency. 0 to 0 V, input resistance 00 kω, accuracy 0 mv equivalent to ±0.% of span. Analogue Current input card Analogue current inputs : channels per card, bit resolution (09 steps). Minimum 0 db series mode rejection at supply frequency. 0 to 0 ma, input resistance 0 Ω 0.%, accuracy 0. % of span (i.e. 00 µa). Analogue Thermistor input card Analogue Thermistor inputs : channels per card, bit resolution (09 steps). Minimum 0 db series mode rejection at supply frequency. Thermistor, bridge resistor 0 kω 0.%, accuracy 0. % of span. Bridge supply V. Digital input card Digital inputs : channels per card. Wetting current Vdc, count rate 3 Hz max. Status LED per channel. ON if contact closed. Analogue voltage output card Analogue voltage outputs : channels per card, bit resolution ( steps). 0 to 0 V with 0 ma current limit, accuracy ±00 mv equivalent to ± % span. Status LED per channel. Light intensity increases with output voltage. CABLE MANAGEMENT SYSTEM Dimensions Material tray cover Protection Weight :0 mm x 3 mm mm (including cover) :Steel :Fire retardant ABS P0 (when fitted to Q/) 0.3 kg Trend Control Systems Ltd reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes. Trend Control Systems Ltd. P.O. Box 3 Horsham Sussex RH YF England Tel:+ (0)03 Fax:+ (0) Q/ Controllers TA0303 ssue /D /0/03

ECB-103 BACnet B-ASC 10-Point Programmable Controllers

ECB-103 BACnet B-ASC 10-Point Programmable Controllers D a t a s h e e t BACnet B-ASC 10-Point Programmable Controllers Overview The is a microprocessor-based programmable controller designed to control terminal units such as fan coil unit, heat pump unit,

More information

IQ212/BOX/ATM Atomic Timemaster

IQ212/BOX/ATM Atomic Timemaster ) + ) + ) + " & $! $ " ' ' $ ata Sheet IQ212/BOX/AT Atomic Timemaster ATOIC TIASTR escription The Atomic Time aster (IQ212/BOX/AT) is an IQ212 controller with a radio controlled clock which will receive

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of wireless I/O provides a low cost alternative

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL This manual covers installation, setup, operation and troubleshooting. Read carefully before attempting to install, operate or

More information

ECL-VAV-N. Features & Benefits

ECL-VAV-N. Features & Benefits D a t a s h e e t ECL-VAV-N Overview The ECL-VAV-N controller is a microprocessorbased programmable variable air volume (VAV) controller designed to control any variable air volume box. This controller

More information

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at

More information

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module

ioselect Z-NET Z-4RTD 4 Channel RTD Input Module 4 Channel nput Module : PT00, PT000, PT500 & N00: 2, 3 & 4 wire 500 V solation, 6-way Modbus Communications Adjustable Sampling Time Accuracy to 0.2 C Configuration and Setup Software EC 63 Flexible Power

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair

More information

Speed and Key Monitor Specifications

Speed and Key Monitor Specifications Speed and Key Monitor Specifications The Speed and Key Monitor is designed for high reliability for the plant s most critical rotating machinery monitoring speed, phase, zero speed and direction of rotation.

More information

Control Systems Ltd. Drawing Definitions WIRING DIAGRAM FOR SSP REMOTE MONITORING PANEL

Control Systems Ltd. Drawing Definitions WIRING DIAGRAM FOR SSP REMOTE MONITORING PANEL 1 4 6 7 8 9 10 11 1 1 14 1 16 17 18 19 0 1 Remote Monitoring Outstation s I** & Wire Numbering Schedule Description Controller input terminals. Ie I+ is connector input and I- is connector common. O**

More information

The wireless alternative to expensive cabling...

The wireless alternative to expensive cabling... The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of telemetry modules provide remote monitoring

More information

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz TAC ATV8, IP55 Variable Speed Drives for Asynchronous Motors. -phase. 80/460 V, 50-60 Hz E-60-24 24 May 2004 ATV 8 IP55 drives are specifically designed for pump and fan applications powered by a three-phase

More information

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed

Datasheet. Octadrive DSP-CN * Applies to Part Number: *This unit has a CobraNet interface installed OCTADRIVE DSP-CN Datasheet Applies to Part Number: 391030 Octadrive DSP-CN * *This unit has a CobraNet interface installed User Notice: No part of this document including the software described in it may

More information

Specification DataFile

Specification DataFile DATUM U & U Ultrasonic Level System Specification DataFile 6-digit backlit l.c.d. and bargraph clear display of measured level Echo Processing using 'DATEM' software true level measurement, overcoming

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

RN Thyristor Controllers

RN Thyristor Controllers Data Sheet RN Thyristor Controllers RN Thyristor Controllers Thyristor Controllers (solid state relays) provide a means of varying the voltage for electrically resistive s, typically electric heating elements.they

More information

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis

More information

Portable Multi-Channel Recorder Model DAS240-BAT

Portable Multi-Channel Recorder Model DAS240-BAT Data Sheet Portable Multi-Channel Recorder The DAS240-BAT measures parameters commonly found in process applications including voltage, temperature, current, resistance, frequency and pulse. It includes

More information

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase

More information

DDC control of package units, heat pumps, unit ventilators, and other terminal unit applications

DDC control of package units, heat pumps, unit ventilators, and other terminal unit applications Infinity TCX 867 Terminal Control Unit F E A T U R E S The Infinity TCX 867 programmable controller is a compact terminal control unit that provides lowcost DDC control of package units, heat pumps, unit

More information

CX-A6 Amplifier Installation & User Guide V9.0

CX-A6 Amplifier Installation & User Guide V9.0 CX-A6 Amplifier Installation & User Guide V9.0 Cloud Electronics Limited 140 Staniforth Road, Sheffield, S9 3HF England Tel + 44 (0) 114 244 7051 Fax + 44 (0) 114 242 5462 E-mail info@cloud.co.uk Web site

More information

HAWK5000 Operators Manual

HAWK5000 Operators Manual HAWK5000 Operators Manual Keison Products P.O. Box 2124, Chelmsford CM1 3UP, England Tel: +44 (0) 1245 600560 Fax: +44 (0) 1245 600030 Email: sales@keison.co.uk www.keison.co.uk KANE INTERNATIONAL LIMITED

More information

maxon document number:

maxon document number: maxon document number: 791272-04 1 Table of contents... 2 2 Table of figures... 3 3 Introduction... 4 4 How to use this guide... 4 5 Safety Instructions... 5 6 Performance Data... 6 6.1 Motor data... 6

More information

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed

PB-400-CN. Datasheet. IndustryAmp PB-400-CN * Applies to Part Number: *This unit has a CobraNet interface installed PB-400-CN Datasheet Applies to Part Number: 590403 IndustryAmp PB-400-CN * *This unit has a CobraNet interface installed User Notice: No part of this document including the software described in it may

More information

OM7AT & OM7AR1 (Stand alone) ROM7AT & ROM7AR1 (Rack mount)

OM7AT & OM7AR1 (Stand alone) ROM7AT & ROM7AR1 (Rack mount) OM7AT & OM7AR1 (Stand alone) ROM7AT & ROM7AR1 (Rack mount) IRIG Time Code Electrical to Fiber Optic Transceiver Operating Manual Rev. 1.3 December 20, 2015 Luxcom Technologies Inc., 102 WALGREEN ROAD,

More information

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual IDA 4 XM V 1.X Installation and configuration of IDA 4 XM User Manual IMPORTANT SAFETY INSTRUCTIONS - Switch the device s power off before any maintenance operation (changing the CU card, etc.) - The 24V

More information

Main Features. Highlights

Main Features. Highlights Highlights For portable use or continuos system; Multi-position measuring system using wireless communication from MASTER to SLAVE units; N.4 analog inputs, n.1 digital inputs; Inputs extension using MASTER/SLAVE

More information

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back

DPA602 1/7. Multi-Channel Network Amplifier. General Description. Features. Applications. AtlasIED.com. DPA602 Front. DPA602 Back 1/7 DPA602 Multi-Channel Network Amplifier Features Configurations 2 x 300 Watt 70V / 100V (Factory Default) 4 x 150 Watt @ 4Ω 1 x 300 Watt 70V / 100V & 2 x 150 Watt @ 4Ω No Computer Required to Operate

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

PLC-K506 Series FEATURES DESCRIPTION FEATURES

PLC-K506 Series FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate With Up to 32 Devices DESCRIPTION

More information

OVEN INDUSTRIES, INC. Model 5C7-362

OVEN INDUSTRIES, INC. Model 5C7-362 OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...

More information

DigiFlex Servo Drive DPQNNIE-060A400

DigiFlex Servo Drive DPQNNIE-060A400 Description The DigiFlex Performance (DP) Series digital servo drives are designed to drive brushed and brushless servomotors. These fully digital drives operate in torque, velocity, or position mode and

More information

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions Wireless Temperature and Humidity Overview and Indentification The Wireless Temperature and Humidity measures the room temperature and Relative Humidity and transmits the data at 418MHz or 433MHz RF to

More information

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification General The VT76x7 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Wireless Data Gathering Panel MODEL TS0825

Wireless Data Gathering Panel MODEL TS0825 Wireless Data Gathering Panel MODEL TS0825 Wireless Data Gathering Panel: Model TS0825 INSTALLATION GUIDE The TS0825 Wireless Data Gathering Panel may be installed up to 1.5km from the Challenger panel

More information

Integrated servo motor

Integrated servo motor R88E-AECT@, R88S-EAD@ Integrated servo motor Motor and drive integrated for space optimization Wide range of motors from 2.55 Nm to 25 Nm 3000 rpm rated speed Peak torque 300% of rated torque IP65 protection

More information

Shaft Absolute Vibration Monitor Specifications

Shaft Absolute Vibration Monitor Specifications Shaft Absolute Vibration Monitor Specifications The Shaft Absolute Vibration Monitor is designed for high reliability for the plant s most critical rotating machinery. This 1-slot monitor is used together

More information

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers Secondary Injection Relay Test Set Designed for testing relays and transducers Two current outputs to test differential relays Convertible current and voltage generator With phase angle shifter Frequency

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

PRO Professional Radio Control Series Applications

PRO Professional Radio Control Series Applications 204 205 Ready to Use Remote Control 4, 8/16 Channel Systems Range: Up to 200 metres at 433MHz Up to 1,000 metres at 433MHz NB Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting

More information

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs Inputs 10 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate with up to 32 devices DESCRIPTION

More information

R-Log Radio data logger

R-Log Radio data logger > data loggers R-Log Radio data logger Highlights For portable use or continuos system; Multi-position measuring system using wireless communication from MASTER to SLAVE units; N.4 analog inputs, n.1 digital

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

SMARTALPHA RF TRANSCEIVER

SMARTALPHA RF TRANSCEIVER SMARTALPHA RF TRANSCEIVER Intelligent RF Modem Module RF Data Rates to 19200bps Up to 300 metres Range Programmable to 433, 868, or 915MHz Selectable Narrowband RF Channels Crystal Controlled RF Design

More information

Radio Data Modem MOD 02

Radio Data Modem MOD 02 Order information Name Type Part No. Radio Data Modem MOD 02 133 610 02 AX 20mA Current Loop / TTY Interface 5V Supply Voltage FFSK Coding (Fast Frequency Shift Keying) Indicating LEDs for Transmit and

More information

Wireless sensor system

Wireless sensor system Wireless sensor system Internet / Ounet PC in internal network GW Internet connection FIGURE 1 structure of wireless sensor network = Base station = Routing wireless sensor = Wireless sensor General description

More information

MEMOCAL 2000/2000S. Hand-held calibrator

MEMOCAL 2000/2000S. Hand-held calibrator MEMOCAL 2000/2000S Hand-held calibrator MEMOCAL 2000 Very low temperature drift (0.1µV/ C) Accuracy: 0.015% of span Power supply: standard AA size battery (Alkaline, NiCd or Ni-MH) Measurement & generation

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

Conductivity Analyzer

Conductivity Analyzer Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures

More information

C-Band Redundant LNA Systems

C-Band Redundant LNA Systems C-Band Redundant LNA Systems LRC-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon

More information

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched EXL6 OCS Datasheet for HE- EXL1E0, HE- EXL1E2, HE- EXL1E3, HE- EXL1E4, HE- EXL1E5, HE- EXL1E6 HEXT371C100, HEXT371C112, HEXT371C113, HEXT371C114, HEXT371C115, HEXT371C116 1. Specifications Required Power

More information

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS

More information

The FM 3517i on-board computer interfaces directly with the vehicle s data bus supporting the CAN - J1939 and J1708 / J1587 standards.

The FM 3517i on-board computer interfaces directly with the vehicle s data bus supporting the CAN - J1939 and J1708 / J1587 standards. PRODUCT FACT SHEET FM3516i, FM 3507i and FM 3517i Overview The FM 3507i (Communicator without backup battery) and FM 3517i (Communicatorbattery) and FM3516i (Tracer), collectively referred to herein as

More information

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials. The equipment described in this manual contains high voltage. Always disconnect power to the equipment before installing, disconnecting, or servicing the product. This product is for use in a dry, indoor

More information

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers Secondary Injection Relay Test Set Designed for testing relays and transducers Microprocessor controlled With phase angle shifter Frequency generator Test results and settings are saved into local memory

More information

Phase and neutral overcurrent protection

Phase and neutral overcurrent protection Phase and neutral overcurrent protection Page 1 ssued June 1999 Changed since July 1998 Data subject to change without notice (SE970165) Features Two-phase or three-phase time-overcurrent and earth fault

More information

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

Uni-Mux XQL Multi-Channel Data Acquisition Module

Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module Uni-Mux XQL Multi-Channel Data Acquisition Module * 8 channel differential inputs. * 16 channel single ended inputs. * User programmable via P.C. software.

More information

X-Band Redundant LNA Systems

X-Band Redundant LNA Systems X-Band Redundant LNA Systems LRX-1000 Series Introduction Redundant LNA systems minimize system downtime due to LNA failure by providing a spare LNA and an automatic means of switching to the spare upon

More information

2601 System SourceMeter 2602 Multi-Channel I-V Test Solutions

2601 System SourceMeter 2602 Multi-Channel I-V Test Solutions 601 System SourceMeter 60 Multi-Channel I-V Test Solutions SPECIFICATION CONDITIONS This document contains specifications and supplemental information for the Models 601 and 60. Specifications are the

More information

7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End FEATURES DESCRIPTION 7RU SSPA Chassis Teledyne Paradise Datacom s 7RU Indoor, High Power Rack Mount series of SSPAs represent the industry s highest power density and most reliable high power amplifier

More information

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual External RF Driver Electrical Driver for AOTF-crystal Instruction Manual Table of Contents 1 General... 3 2 Compliance... 3 3 Labeling... 4 4 Interface... 5 4.1 Front Panel... 5 4.2 Back Panel... 6 4.2.1

More information

Z4MK3/Z8MK3 : Zone Mixers

Z4MK3/Z8MK3 : Zone Mixers ZMK/ZMK : Zone Mixers Clearly better sound. mm Z MK Four Zone Venue Mixer Microphone Microphone Paging Mic Level Music Source Music Level. mm (U) / Power Mute Zone Zone Zone Zone ZMK Zone Mixer Z MK Eight

More information

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE -175 AC/DC Power Supply Series APPLICATION NOTE 69493 NV175 App note 4.doc Document Number 69493 Page 1 of 17 1. INPUT...3 AC INPUT LINE REQUIREMENTS... 3 2. DC OUTPUT...3 OUTPUT VOLTAGES... 3 REMOTE SENSE...

More information

K3P ENG.qxd 23/10/ Pagina 1

K3P ENG.qxd 23/10/ Pagina 1 K3P ENG.qxd 23/10/2003 12.30 Pagina 1 - CLEAR PROGRAM STATUS DISPLAY - DIRECT PROGRAM PARAMETER ADJUSTMENT - 8 INDEPENDENT PROGRAMS - 10 SEGMENTS FOR EACH PROGRAM - "SET - POINT TRACKING " AND "GUARANTEED

More information

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR).

RETROFITTING. Motor Protection Relay. Two mountings are available, Flush Rear Connection (EDPAR) or Projecting Rear Connection (SDPAR). RETROFITTING Motor Protection Relay NPM800R (R2 case) and NPM800RE (R3 case) are dedicated to the refurbishment of 7000 series (R2 and R3 cases) of CEE relays providing the protection of medium voltage

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

TORKEL 900-series Battery Load Unit

TORKEL 900-series Battery Load Unit Batteries can be tested in service Dynamic discharge technology full power at all voltages Safety in all details, e.g. detection of blocked airflow Real time monitoring during test Quick report Easily

More information

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series OPERATION MANUAL INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series VOICE ALARM SYSTEM AMPLIFIER VM-3240VA VOICE ALARM SYSTEM AMPLIFIER VM-3360VA VM EXTENSION AMPLIFIER VM-3240E VM EXTENSION AMPLIFIER VM-3360E

More information

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features AR-DN-RS232 An-10 / Rapid RS232 Interface Product Guide Overview The AR-DN-RS232 is a device that is used as a 2 way gateway between third party systems and the CP An-10 or Rapid lighting control systems

More information

Ouput Loop Powered Products Section C

Ouput Loop Powered Products Section C Ouput Loop Powered Products Section C An output loop powered (or signal powered) isolator derives its power from the voltage drop across the device's current loop output. Because they require no separate

More information

Wireless 900 MHz Receiver

Wireless 900 MHz Receiver Overview and Identification The 900 MHz unit receives a repeated or re-transmitted RF signal from one or more wireless temperature or humidity transmitters. The signal from the transmitter (418 MHz) is

More information

Paperless Recorder PR20

Paperless Recorder PR20 Technical Information TI 075R/24/ae Paperless Recorder PR20 Economical and time saving recorder operates without the need for paper or pens and is exceedingly simple to operate Application Areas Technological

More information

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard

More information

BLuAC5 Brushless Universal Servo Amplifier

BLuAC5 Brushless Universal Servo Amplifier BLuAC5 Brushless Universal Servo Amplifier Description The BLu Series servo drives provide compact, reliable solutions for a wide range of motion applications in a variety of industries. BLu Series drives

More information

CAN-IO Custom IO remote module

CAN-IO Custom IO remote module CAN-IO Custom IO remote module Main characteristics High customization Integrate different types of inputs/ outputs Up to 40 total channels DIN rail mount or plate Main applications Climatic chambers Autoclaves

More information

MA80FT Mini Amplifier

MA80FT Mini Amplifier MA8FT Mini Amplifier LF HF MA8FT 8W MIXER AMPLIFIER OFF 1 OFF 1 STATUS MUTE PEAK OFF 1-1 db +1-1 db +1 MUSIC EQ MA8FT Front Panel PAGE/ INPUT +5 +1 db HI-Z SPKR IN 7/ - -1V SETTINGS 1: / PAGE MODE 2: /

More information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Sarasota CM200 Sarasota HME900 Density Converter Electronics Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

English RACON SERIES II RADIO CONTROL SERVICE MANUAL English 22.2.2007 RACON SERIES II RADIO CONTROL SERVICE MANUAL Read the instructions supplied with the product before installation and commissioning. Keep the instructions in a safe place for future reference.

More information

PERMA Series Revision 2 Amplifiers

PERMA Series Revision 2 Amplifiers PERMA Series Revision 2 Amplifiers High Efficiency Life Safety Digital Power Amplifiers Current Thinking Document Number DDC PER 7001 02 ACS Introduction Voice Alarm (VA) systems are the quickest way to

More information

Remote Site Monitoring

Remote Site Monitoring Remote Site Monitoring FEATURES AT A GLANCE Codan Radio Communications now offers Remote Site Monitoring options that provide live site information, giving you the power to respond intelligently to communications

More information

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems

Comm Series DC Power Supplies Radio Base Station Covers Battery Chargers DC UPS Backup Systems Product Catalog 2014 Condensed Version INNOVATIVE CIRCUIT TECHNOLOGY LTD. ICT has been providing DC power conversion products since 1986 for two-way wireless communications, fixed wireless broadband and

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

SR3400 Base Station Module Configuration and Use Series-2 Cards Only

SR3400 Base Station Module Configuration and Use Series-2 Cards Only SR3400 Base Station Module Configuration and Use Series-2 Cards Only A.W. Communication Systems Ltd Crook Barn, The Crook Rowel Town, Carlisle Cumbria Telephone (44) 1697-748777 Fax (44) 1697-748778 www.toneremote.com

More information

F2A3X Frequency to Analog Converter Module

F2A3X Frequency to Analog Converter Module the professional s choice F2A3X Frequency to Analog Converter Module Instruction Manual MONARCH INSTRUMENT 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Multiple sensor types supported with one instrument Dial-type digital bar graph Modules are field installable and replaceable

More information

C-Band VSAT Block Up Converters

C-Band VSAT Block Up Converters FEATURES Single box BUC output power levels to 20W RS485 M&C capability Accurate RF Power Monitoring Maintenance Free Operation +24VDC or +48 VDC input voltage OPTIONS Antenna Mounting Kit Form A Summary

More information

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters. ~ ~ SX High performance Vector Control IP54 full range. Compact design & Robustness Built-in Filter according to C3 Class Built-in Fusses (From 200 kw) Safety according EN13849-1 and EN62061 standards

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

Wireless Analog Output Modules

Wireless Analog Output Modules Overview and Product Identification Wireless Analog s Analog s receive data from a BAPI 418 MHz receiver or 900 MHz receiver through a four-wire RS 485 bus. Up to 127 different Analog s can be connected

More information

AC/DC Power Supply Series APPLICATION NOTE

AC/DC Power Supply Series APPLICATION NOTE -175 AC/DC Power Supply Series APPLICATION NOTE 69493 NV175 App note 6a.doc Document Number 69493 Page 1 of 20 1. INPUT... 4 AC INPUT LINE REQUIREMENTS... 4 2. DC OUTPUT... 4 OUTPUT VOLTAGES all models

More information