1 ) + ) + ) + " & $! $ " ' ' $ ata Sheet IQ212/BOX/AT Atomic Timemaster ATOIC TIASTR escription The Atomic Time aster (IQ212/BOX/AT) is an IQ212 controller with a radio controlled clock which will receive highly accurate time signals, and use this to automatically synchronise a complete Trend building management system. The controller retains its general functionality and contains pre-configured strategy to monitor and control the clock. The controller is contained in a metal box complete with glands for the supply and receiver cables, cable glanding grommets, and a short length of IN rail with an earthing terminal. The radio controlled clock consists of a desk or panel mounting display a junction box, and a remote antenna in a weatherproof box. The display indicates both the time and the signal strength Features Accurate system clock traceable to National Physical Lab. Automatic daylight saving time change Trend system timemaster functionality General IQ212 controller functionality Receiver fail detection Time update inhibit esk or panel mounting display showing time and signal strength Remote antenna with signal strength indication Physical dimensions in mm plan view shown with lid open cable glanding grommet to radio controlled clock, see page two 100 mm cable strain relief grommet IQ212 N N RJ11! " # $ % & '! " #! Security screw IN rail (150 mm) earthing terminal Cable glanding grommets 20 cable gland (supply) IQ212/BOX/AT, Atomic Timemaster ata Sheet TA2007 Issue 2/B 2/10/02 1

2 IQ212/BOX/AT ata Sheet PHYSICAL (continued) dimensions in mm isplay Unit Jack Socket connects to 125 junction box 30 Junction Box Jack plug connects to display unit 0 cable to 55 antenna Reset button at rear RJ11 connects to IQ cable to junction box FUNCTIONALITY The radio controlled clock receives the time signal and communicates the time and date to the /AT controller. The controller incorporates special firmware to communicate with the radio controlled clock, to set the time and status bits in the controller, and to synchronise the system. The controller also contains some strategy to monitor the receiver status bits, control the clock, and indicate signal strength. RAIO CONTROLL CLOCK The radio controlled clock is connected to the /AT controller via the supervisor port (RJ11). It receives a radio signal and transmits it as an RS232 signal to the supervisor port. It tunes to the SF radio station at the NPL Rugby and must be within 1500 km (937.5 m) of the station; this covers UK and Ireland. The clock consists of the antenna, junction box, and display unit, connected together in that order and then to the /AT controller. antenna junction box screw terminals jack plug display unit RJ11 IQ212 The antenna is supplied in a weatherproof box. The cover can be removed using four screws to reveal the red signal indicator L. This will flash steadily every second if a good signal strength has been achieved. If the L is constantly on or off, the receiver is not getting a good signal. The antenna is supplied wired to the junction box by a 1300 mm cable. This can be rewired using 0.2 mm, core security or alarm cable (CAT 5 structured cable can also be used) up to a maximum length of 150 m. Junction box The junction box cover can be removed using one screw in order to fix it to the wall, or to rewire the connection to the antenna. It is fixed to a flat surface via 2 3 screws. The junction box has a 100 mm flying lead terminated in a jack plug which plugs into the display unit. isplay Unit The display unit can be mounted on the desk or on a panel. There are two holes in the rear of the unit which can either hold the panel mounting bracket, or two triangular plates which enable it to be stood on a desk. The panel mounting bracket screws to the panel with two 3 screws. panel fixing reset button The antenna box can be fixed to the wall using screws. suggestion for mounting antenna conduit desk mounting 20 coupling 2 IQ212/BOX/AT, Atomic Timemaster ata Sheet TA2007 Issue 2/B 2/10/02

3 ata Sheet IQ212/BOX/AT It has a jack socket in the side for connection to the flying lead from the junction box. It also has a flying lead terminated in an RJ11 plug for connection to the /AT controller supervisor port. The /AT controller connection carries both signal and power. The display normally shows the time (hh:mm:ss), a radio tower symbol, and the date in American format (mm:dd, i.e means 1th July). time # %! % $ radio pylon date isplay As the unit is powered up all the segments light for one second, and the time display starts counting seconds from zero. This indicates the start of the radio signal reception attempt. The signal strength is indicated by four signal strength bars running across the display from the top of the radio pylon. seconds count up! signal strength bars One bar means weak or no reception, bars mean excellent reception. When the radio station has been picked up the radio tower symbol starts blinking. After an average of 3½ minutes (3 to minutes) the actual time appears on the display and the radio tower stops blinking. If the clock cannot receive the time within seconds, it will enter an idle mode; the antenna symbol disappears from the display and the seconds count up. Further attempts will be made every hour until the unit picks up the time. The unit can be forced to restart its reception attempt by cycling its power (i.e. cycling the power to the /AT controller) with a 1 minute wait before re-powering, or by pressing the display s reset button. The reset button is a small pinhole button situated in the rear of the unit. Reception The receiver must be correctly orientated to receive the signal. It should be positioned as high as possible in a window or on an outside wall facing the radio station. The signal is strongest when the antenna is orientated at right angles to the signal from Rugby. The antenna box should be mounted with its junction box cable coming from the bottom of the antenna box and a face of the antenna box facing Rugby. cable to junction box at bottom of unit antenna view onto top of unit right angles to signal Rugby transmitter The recommended method is to remove the antenna cover to view the signal strength L and orientate the antenna so that the L stops flashing, indicating minimum signal strength. Then rotate the antenna by 90, and check that the signal strength L consistently flashes at 1 second intervals. c a b The signal strength is also indicated in the display as described above and should be a minimum of 3 bars. Signal strength can also be measured by a voltmeter connected to output channel 1 (OUT1/ AO); the signal range is 0 to 5 V, and should be 3 V or greater. It should take an average 3.5 minutes (3 to minutes) for the receiver to establish valid time and date information after it is powered up. Once the /AT controller firmware has established a signal strength of 3 bars or greater (3 V or greater), it will synchronise. It is recommended that attempts should be made for a greater signal strength (e.g. bars or 5 V) by making smaller angular changes to the receiver position, cycling the power with a 1 minute wait before re-powering for each attempt, and checking the signal strength bars, or the voltage reading. After synchronization, if there is a communications fault between the /AT controller and the receiver, a subsequent attempt at synchronisation will generate a Receiver Comms Fail alarm, but if the synchronisation was due to a power cycle, it will still show the previous signal strength. For a full system test, change the time of one of the controllers being synchronised, induce a synchronisation by cycling the /AT controller s power, and check the controller is resynchronised with the correct time. The following sources of interference may prevent reception of a strong signal: omestic appliances without radio interference suppression Computer monitors closer than 2 metres away TV receivers closer than 2 metres away achinery with high H.F leakage Poor atmospheric conditions (e.g. stormy weather) Poor reception may also be experienced in low lying areas, or in metal clad buildings. Signal strength improves at night so leaving the receiver overnight may establish the time and date. Gaps in Reception The radio station may be subject to routine maintenance, so the station should be contacted directly to check for details of shutdowns (Rugby tel.: + (0) ). The receiver will maintain accurate time to an accuracy of 0.01 seconds maximum drift per 2 hour period that the radio time is not available. aylight Saving, BST/UTC The Atomic time used is UTC, Coordinated Universal Time which is the agreed international atomic time (with minor corrections for earth s rotation etc.). This is approximately the same as GT. BST, British Summer Time is 1 hour ahead of UTC. The receiver gives three status indications: BST is in effect: When this status is one it means the current time is summer time, BST. When this status is zero, the current time is GT. UTC is in effect: The logical inverse of BST is in effect. BST/UTC change impending: This status is one for the half hour before the change from GT to BST or vice versa from BST to GT. " # " # IQ212/BOX/AT, Atomic Timemaster ata Sheet TA2007 Issue 2/B 2/10/02 3

4 IQ212/BOX/AT ata Sheet /AT CONTROLLR The /AT controller consists of an IQ212 with special firmware and a small amount of pre-configured strategy. /AT Firmware The /AT controller has additional firmware to communicate with the receiver and to synchronise the IQ timer module and the rest of the system. It also sets values and status in the arrays as listed below and has one switch module to inhibit time update: B28,0 BST/UTC change impending B28,1 BST is in effect B28,2 UTC is in effect B29,0 AT Receiver Valid Time B29,1 One attempt since 3:00 am Successful B3 Cable/Receiver Failure B31,0 Inhibit Time Update A220 Signal Strength /AT Strategy The pre-configured strategy installed in the /AT controller takes the values and status set by the /AT firmware in the arrays, and makes them available as internal digital inputs. It drives the voltage output, and enables W1 to inhibit the time update Signal Strength S12 S 220 INTRNAL Signal Strength Units 0to5 xponent 3 High Alarm Limit 10 Low Alarm Limit 2 Low Alarm elay 5 V 12 P1 PLOT Sensor 12 Period 15 in P2 PLOT Sensor 12 Period 1 in 1 0 F2 102 G 220 F 10 RSCL TO =100(G-)/(F-) S F2 3 1 L A Alarm ANALOGU Signal Strength Range ,0 R 29,0 AT Receiver Valid Time = 1 29,1 One attempt since 3:00am Successful 29,0 F 29,1 G H K = G1 COB e f I9V 3 Cable/Receiver Failure F G H 3 7 G COB I12V W1 S 18,0 I10 S 2,1 28,0 BST/UTC change impending 28,0 F G 5 G2 I10V W1V 18,0 Inhibit Time Update From Page 2 F G W1V 8 G5 31,0 SWITCH Inhibit Time Update Pin Level 0 Status 0 INTRNAL BST-UTC Imminent Required 0 nabled 0 elay 0 28,1 BST is in effect = 1 28,2 UTC is in effect = 1 H 28,1 F 28,2 G H COB G3 COB f I11V H COB 31,0 1=Time Update Inhibit I9 INTRNAL Time Update Failure Required 0 nabled 1 elay 0 S 2,0 I11 INTRNAL BST in effect Required 0 nabled 0 elay 0 I12 INTRNAL S 2,2 S 2,3 Receiver Comms Fail Required 0 nabled 1 elay 0 AT Strategy Schematic IQ212/BOX/AT, Atomic Timemaster ata Sheet TA2007 Issue 2/B 2/10/02

5 ata Sheet IQ212/BOX/AT /AT Strategy (continued) Signal Strength With reference to the strategy diagram, the signal strength from analogue node 220 is monitored by S12 (Signal Strength). The sensor is logged at both 15 minute and 1 minute intervals by plotting channels 1 and 2 respectively. The signal strength is in the range 0 to 5 (with a good signal being greater than 3). Function module F2 rescales the signal to 0 to 50. The output of F2 drives the analogue driver 1 to give a signal of 0 to 5 V on output channel 1 (OUT1/AO). Time Update Failure The logic module G1 generates internal digital input I9 when either /AT controller hasn t a valid time, or if there hasn t been one successful attempt since 3:00 am. The required state of I9 is 0, and its alarm is enabled so that it will generate a Time Update Failure alarm (if the alarm target address and Lan are set up) if the time is invalid, or if there isn t a single successful update in a 2 hour period. Internal igital Inputs Logic module G3 generates internal digital input I11 from the logical combination of BST is in effect and not UTC is in effect. Logic modules G2,and G generate internal digital inputs I10 and I12 from the BST/UTC change impending and Cable/Receiver Failure signals respectively. The internal digitals are labelled as listed below. The required state of I12 is set to 0, and its alarm is enabled so that it will generate a Receiver Comms Fail alarm (if the alarm target address and Lan are set up) if there is a cable or receiver failure. Inhibit Time Update Switch 1, Inhibit Time Update (W1) causes G5 to set bit 31,0 which causes the receiver to stop updating the controller. HARWAR Box: The /AT controller is enclosed in a metal box which has cable glanding grommets in the lower edge and a single grommet in the top edge for signal and network cables. It also has a strain relief gland for the /AT receiver cable, and an 20 gland for the supply cable. The box contains the /AT controller (IQ212) and a 150 mm length of IN rail. A single earth terminal is supplied installed on the IN rail to facilitate connection of mains supply earth. Receiver: The receiver consists of three parts, the antenna, junction box, and the display unit as described above (see functionality, Radio Controlled Clock). /AT Controller: The /AT controller is an IQ212 with additional firmware and some pre-configured strategy. All the features of a standard IQ212 controller at v3.01 firmware level are available for use other than a few small exceptions as listed below. The standard controller details are given in the IQ21x data sheet, TA200012: The pre-configured strategy uses some of the modules, and array nodes (as shown in diagram above) Output channel 1 (OUT1/AO) is used for the signal strength voltage output. The receiver uses the local supervisor port, so a local supervisor cannot be connected; the controller can only be configured via the network. Strategy Backup :It is recommended that the pre-configured strategy should be backed up to create a AT default file. If required, additional strategy can be added to this strategy observing the special array values and taking care not to overwrite the modules. This strategy should be backed up separately. Strategy Items I9 Time Update Failure I10 BST-UTC Imminent I11 BST in ffect I12 Receiver Comms Fail W1 Inhibit Time Update S12 Signal Strength IQ212/BOX/AT, Atomic Timemaster ata Sheet TA2007 Issue 2/B 2/10/02 5

6 IQ212/BOX/AT ata Sheet SYST The /AT acts as a special timemaster. It will automatically synchronise a complete building management system, but if the system has autodialled sections, these should have their own timemasters. The /AT will synchronise all controllers on the system by sending out a global global time synchronisation message on power up and every hour, as long as the receiver has received one valid signal in the last 2 hours (see Time Update Failure, I9). [The actual reception attempt occurs at 5 minutes past the hour, and it requires 3 minutes of continuous reception as it receives further data, so the system synchronisation should occur at 8 minutes past the hour approximately.] The global global time message is acceptable to both IQLs and IQs, so the /AT will synchronise the whole system (excluding autodialled controllers). Since this message uses attribute comms, if an IQ or IQL on the system has a PIN set up, the /AT must have an identical password as that set up in the controller and with level 99. In order that any traditional IQ timemasters on the system do not interfere with the AT synchronisation, the AT will automatically null down their timemaster functionality. It will do this on power up and at.05 am each day. Traditional timemaster functionality is switched on by setting the time module change by value to non-zero. (Note that the AT does not require this to be done in order for it to act as a timemaster.) The /AT will stop any other controller from being a timemaster (including stopping its own traditional time master functionality, if set up) by sending out a global global message that clears all controllers time module change by values to zero. INSTALLATION The antenna is weatherproof (IP5) and can be mounted outside the building if necessary. All the other parts must be mounted inside the building. The installation procedure involves: ount /AT controller, display unit, and junction box in position connect units together and to antenna If necessary extend cable between antenna and junction box connect power (do not switch on) Perform IQ212 installation Switch on power to unit Open antenna box Check signal strength by observing L and re-orientating receiver as appropriate Check signal strength on display (or AT controller voltage output) Permanently mount antenna Configure strategy to: use /AT parameters set up timemaster function Test system Backup configuration Full details of IQ212 installation are given in IQ21x series installation instructions, TG Additional details required for /AT installation are given in IQ212/BOX/AT installation instructions TG IQ212/BOX/AT, Atomic Timemaster ata Sheet TA2007 Issue 2/B 2/10/02

7 ! " # $ ) + % & ) + ' ) +! " # N N " & $! $ " ' ' $ ata Sheet IQ212/BOX/AT CONNCTIONS Junction Box cable from cable to Junction Box Jack plug to isplay Unit signal L R Blk Y Blu Junction Box isplay Unit Jack socket 230 Vac Supply 2 part N L RJ11 supervisor port cable to /AT controller box earth 1 2 3! 8 Network 2 wire ) Inputs N L 230 Vac Outputs wire : : : : A = HJ > K I ) : 13 $ 8 % & ) + ' ) +! " # ! 1 " ! " 7 " 7 # " 7 $ 8 =? 8 =? ) $ 8 ) %, & ", ' 8 =? ",, 8 =? $ 8 : : : : A = HJ > K I : additional terminals if required IQ212/BOX/AT, Atomic Timemaster ata Sheet TA2007 Issue 2/B 2/10/02 7

8 IQ212/BOX/AT ata Sheet ORR COS IQ212/BOX/AT/UK/230: Atomic timemaster for UK, 230 Vac supply SPCIFICATION Receiver Accuracy :1 second in years istance :1500 km from radio station imensions antenna :125 x 35 x 30 mm junction box :55 x 0 x 23 mm display unit :130 x 95 x 55 mm Cables antenna :1300 mm cable to junction box supplied. Can be rewired using 0.2 mm, core security or alarm cable (or CAT 5 structured cable) up to 150 m. junction box :flying lead (100 mm) to display unit terminated in jack plug. display unit :flying lead (1000 mm) to /AT controller terminated in RJ11 plug Signal L :under cover in antenna. Red L will flash steadily at one second intervals to indicate good signal. L is constantly on or off, indicates weak signal. isplay :liquid crystal. isplays time (hh:mm:ss), date (mm:dd), and radio tower symbol to indicate reception. uring reception attempt, tower flashes and signal strength indicated by bars in the display. Good signal is 3 to bars Reset button :pinhole button in rear of display unit restarts reception attempt. Controller Supply :230 Vac %, 50 to 0 Hz Consumption :13 VA max. Supervisor :port used for receiver Inputs/Outputs :2 thermistor inputs, 1 universal input 2 digital inputs, 2 analogue outputs (one used for signal strength as see below), digital outputs Signal Strength :uses analogue output channel 1 (OUT1 AO). Output 0 to 5 V. Good signal is =>3 V (Full IQ212 controller specification given in IQ21x data sheet, TA200012) Box imensions aterial IN rail :280 x 180 x 80 mm :1.2 mm mild steel :150 mm Version Firmware :IQ21x v3.01 Strategy :issue 1.1 Trend Control Systems Ltd reserves the right to revise this publication from time to time and make changes to the content hereof without obligation to notify any person of such revisions or changes. Trend Control Systems Ltd. P.O. Box 3 Horsham Sussex RH12 2YF ngland Tel:+ (0) Fax:+ (0) IQ212/BOX/AT, Atomic Timemaster ata Sheet TA2007 Issue 2/B 2/10/02

IQ241/242 Controllers

IQ241/242 Controllers Q/ Controllers Q/ CONTROLLERS Description Features The Q/ controllers are of medium capacity designed for the control of all types of building plant. They can provide a minimum of digital inputs, and analogue

More information

Control Systems Ltd. Drawing Definitions WIRING DIAGRAM FOR SSP REMOTE MONITORING PANEL

Control Systems Ltd. Drawing Definitions WIRING DIAGRAM FOR SSP REMOTE MONITORING PANEL 1 4 6 7 8 9 10 11 1 1 14 1 16 17 18 19 0 1 Remote Monitoring Outstation s I** & Wire Numbering Schedule Description Controller input terminals. Ie I+ is connector input and I- is connector common. O**

More information

Aqua-Gen 3BR INSTRUCTIONS

Aqua-Gen 3BR INSTRUCTIONS Aqua-Gen 3BR INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLLER: Find a suitable location to mount the control box* radio note. The controller must be installed out of direct weather and no closer than

More information

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features.

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features. Instruction Manual DESCRIPTION The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features. Aquasun 3 RP Instruction rb2.docx 1 INSTALLATION INSTRUCTIONS

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

Modular Radio Telemetry System

Modular Radio Telemetry System Simple to Use Remote Control 8 Channels per Transmitter 16 Channels per Receiver Upto 48 Transmitters per system Auto Transmit Mode Secure RF Protocol Automatic Watchdog Transmission Range: Upto 200 metres

More information

Wireless Data Gathering Panel MODEL TS0825

Wireless Data Gathering Panel MODEL TS0825 Wireless Data Gathering Panel MODEL TS0825 Wireless Data Gathering Panel: Model TS0825 INSTALLATION GUIDE The TS0825 Wireless Data Gathering Panel may be installed up to 1.5km from the Challenger panel

More information

Aqua-Gen 3PV INSTRUCTIONS

Aqua-Gen 3PV INSTRUCTIONS Aqua-Gen 3PV INSTRUCTIONS INSTALLATION INSTRUCTIONS CONTROLLER: Find a suitable location to mount the control box* radio note. The controller must be installed out of direct weather and no closer than

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this compact 868MHz Temperature Station which displays radio controlled time, date, indoor and outdoor

More information

Bellman BRUGERVEJLEDNING. Fyrtårn Flash BE1441

Bellman BRUGERVEJLEDNING. Fyrtårn Flash BE1441 Bellman EN BRUGERVEJLEDNING Fyrtårn Flash BE1441 Introduction The Visit system consists of a number of radio transmitters and receivers. The transmitters detect different events in the surrounding area

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this temperature station with wireless 868MHz transmission. It not only displays the indoor temperature

More information

433 MHZ REMOTE THERMO

433 MHZ REMOTE THERMO 433 MHZ REMOTE THERMO INTRODUCTION: Congratulations on purchasing this innovative 433MHz Remote Thermo which displays the time with up to the minute indoor and up to five outdoor temperature readings.

More information

PRO Professional Radio Control Series Applications

PRO Professional Radio Control Series Applications 204 205 Ready to Use Remote Control 4, 8/16 Channel Systems Range: Up to 200 metres at 433MHz Up to 1,000 metres at 433MHz NB Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting

More information

4DIX/24VAC Four Digital Input Expander Module

4DIX/24VAC Four Digital Input Expander Module ata heet IX/A our igital Input xpander Module our igital Input xpander Module escription The igital Input xpander allows volt free inputs to be monitored by a single analogue input channel. The resultant

More information

WIRELESS 868 MHz WEATHER STATION

WIRELESS 868 MHz WEATHER STATION WIRELESS 868 MHz WEATHER STATION Instructions Manual INTRODUCTION: Congratulations on purchasing this Weather Station with wireless 868 MHz transmission of outdoor temperature and display of indoor temperature,

More information

RN Thyristor Controllers

RN Thyristor Controllers Data Sheet RN Thyristor Controllers RN Thyristor Controllers Thyristor Controllers (solid state relays) provide a means of varying the voltage for electrically resistive s, typically electric heating elements.they

More information

WIRELESS 433MHZ WEATHER STATION

WIRELESS 433MHZ WEATHER STATION WIRELESS 433MHZ WEATHER STATION INTRODUCTION: Congratulations on purchasing this Weather Station with wireless 433MHz, which displays time/date, indoor/outdoor temperature and humidity, and receives up

More information

CONTENTS. La Crosse Technology, Ltd. Page 1

CONTENTS. La Crosse Technology, Ltd. Page 1 WT-5220U-IT FAQS The links below will work in most PDF viewers and link to the topic area by clicking the link. We recommend Adobe Reader version 10 or greater available at: http://get.adobe.com/reader

More information

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8 PRO-BLADE8 Ready to Use Remote Control 8 Channel Systems Range: PROFLY Up to 100 metres PROBLADE Up to 500 metres Relay Outputs: Momentary, Latching, Timed Receiver IP65 Applications Lighting Control General

More information

Wireless sensor system

Wireless sensor system Wireless sensor system Internet / Ounet PC in internal network GW Internet connection FIGURE 1 structure of wireless sensor network = Base station = Routing wireless sensor = Wireless sensor General description

More information

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 OPERATING INSTRUCTIONS ARE ON PAGE 5 RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 This Programmable Ravenheat R/F controlled room Thermostat RVHT 2, consists of 2 items: a Mobile Transmitter

More information

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308 433MHz HAND HELD GIGALINK TRANSMITTERS GLT43300, GLT43301, GLT43302, GLT43303, GLT43304 and GLT43308 Features One, two, three, four & eight buttons. More than four billion code combinations Ability to

More information

Installation Instructions

Installation Instructions SYSTXBBSAM01 EVOLUTION SYSTEM ACCESS MODULE Installation Instructions NOTE: Read the entire instruction manual before starting the installation. pointsett U.S. Pat No. 7,415,102 Fig. 1 - Evolution System

More information

200, 201 Series Radio Telemetry Transmitters

200, 201 Series Radio Telemetry Transmitters 200 DIN Rail Transmitter Encoder Up to 8 Input Channels Volt Free contact Inputs via Screw Terminals 12 / 24Vdc Supply Range; 433MHz Up to 200 Metres 433MHz NB Up to 1,000 Metres 458MHz Up to 6,000 Metres

More information

Wireless Pressure Station with Backlight

Wireless Pressure Station with Backlight Wireless Pressure Station with Backlight FORECAST RELATIVE PRESSURE PRESSURE HISTORY inhg -24h -18h -12h -9h- 6h -3h0 h INDOOR For online video support: http://bit.ly/laxtechtalk Model: 308-1417BL DC:

More information

Connecting Mains Electrical Power

Connecting Mains Electrical Power Tide Level Monitoring Instrumentation The following documentation details the electrical installation for the tide level monitoring instrumentation and also a summary of the logger configurations required

More information

R PROFLAME Instruction Book Collection

R PROFLAME Instruction Book Collection 9.956.028 R00 584 PROFLAME Instruction Book Collection 4-17 18-29 584 PROFLAME System 30-39 Appendix: DIP SWITCH NUMBER (0=ON 1=OFF) 40-41 4-17 Fig. 1 The SIT is a device that allows, in conjunction with

More information

Eltek TU GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions

Eltek TU GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions Eltek TU1043 - GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions System configuration diagram GD900A NDRail350 AC supply 240V nominal RS485 AC AC AC For 1 x three phase load

More information

OVEN INDUSTRIES, INC. Model 5C7-362

OVEN INDUSTRIES, INC. Model 5C7-362 OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...

More information

Operating instructions. Radio weather station

Operating instructions. Radio weather station Operating instructions Radio weather station 0334.. Notes regarding the battery Batteries and button cells do not belong in the hands of children. Contact a doctor immediately if a button cell has been

More information

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16 MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model LD120T Series The LD120T is a series of single channel inductive loop detectors. The use of microprocessor and surface mount technology enables a large number of functions

More information

GMS-xx GSR-IAxx User Manual Appendix Simple Interconnection Network

GMS-xx GSR-IAxx User Manual Appendix Simple Interconnection Network GMS-xx GSR-IAxx User Manual Appendix Simple Interconnection Network GeoSIG Ltd, Ahornweg 5A, 5504 Othmarsingen, Switzerland Phone: + 41 44 810 2150, Fax: + 41 44 810 2350 info@geosig.com, www.geosig.com

More information

SIMREX Corporation Your Trusted Wireless Solution Provider

SIMREX Corporation Your Trusted Wireless Solution Provider SIMSYNC Instruction Manual Traffic Controller Time Synchronization System Firmware Release 1.7 SIMREX MAN.SIMSYNC, Rev 8.0 MARCH 2006 Your Trusted Wireless Solution Provider www.simrex.com Introduction

More information

TX CONTROLLER Model EM-IP Quick Start Guide

TX CONTROLLER Model EM-IP Quick Start Guide TX CONTROLLER Model EM-IP Quick Start Guide 860 boul. de la Chaudière, suite 200 Québec (Qc), Canada, G1X 4B7 Tel.: +1 (418) 877-4249 Fax: +1 (418) 877-4054 E-Mail: gdd@gdd.ca Web site: www.gdd.ca Visit

More information

Fuzzy Temperature Controllers E5AF

Fuzzy Temperature Controllers E5AF Fuzzy Temperature Controllers 1/4 DIN Controller Combines Fuzzy and PID Control For Fast Response to Process Disturbances Advanced PID control provides optimal response during start-up and steadystate

More information

BCV-1203 Barcode Verification System Users Guide Version 1.2

BCV-1203 Barcode Verification System Users Guide Version 1.2 BCV-1203 Barcode Verification System Users Guide Version 1.2 6 Clock Tower Place Suite 100 Maynard, MA 01754 USA Tel: (866) 837-1931 Tel: (978) 461-1140 FAX: (978) 461-1146 http://www.diamondt.com/ Liability

More information

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive

More information

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic

More information

P178252GB DELTA RC WIRELESS WEATHER STATION INSTRUCTION MANUAL

P178252GB DELTA RC WIRELESS WEATHER STATION INSTRUCTION MANUAL P178252GB070 74292 DELTA RC WIRELESS WEATHER STATION INSTRUCTION MANUAL Thank you for your purchase of this delicate Wireless Weather Station. Once you have inserted the batteries the clock will automatically

More information

WIRELESS Energy Monitor - Smart Meter

WIRELESS Energy Monitor - Smart Meter Energy saving made simple MONITOR CONTROL SAVE WIRELESS Energy Monitor - Smart Meter Monitors your electricity use and cost in real time Instruction Manual EW4500 IMPORTANT Please retain your Instruction

More information

IntelPage 5W (POCSAG) Transmitter

IntelPage 5W (POCSAG) Transmitter A division of NESS CORPORATION PTY LTD IntelPage 5W (POCSAG) Transmitter INSTALLATION MANUAL IntelPage 5W (POCSAG) Transmitter Installation Manual v1.2 1. Contents 1. Contents... 1 2. Equipment List...

More information

Proximity-Sensor Counter Installation Instruction Model: MRC-PRO

Proximity-Sensor Counter Installation Instruction Model: MRC-PRO Proximity-Sensor Counter Installation Instruction Model: MRC-PRO NYS DOT Approval SYSDYNE CORP. 1055 Summer St. 1 st Floor Stamford, CT 06905 Tel: (203)327-3649 Fax: (203)325-3600 Contents: Introduction...

More information

Answering frequently asked Questions (Firmware V.107)

Answering frequently asked Questions (Firmware V.107) FAQ EasyConn Profibus plug Answering frequently asked Questions (Firmware V.107) EasyConn LEDs: While connected, the Profibus connector offers the following test functions for start-up and trouble shooting

More information

AMB-1200C Deactivator Controller and AMB-1200A Countertop Antenna

AMB-1200C Deactivator Controller and AMB-1200A Countertop Antenna AMB-1200C Deactivator Controller and AMB-1200A Countertop Antenna Installation Guide Regulatory Restriction: In certain countries, there may be installation restrictions on the antennas. See antenna installation

More information

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)

ATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE) USER MANUAL ATS-I Tel.+39.0522.832004 P1/17 ATS-I User manual Fax.+39.0522.832012 Tecnoelettra_EN.doc P.1/17 Index General description...3 Electrical specifics...3 Device operative logic...4 Manual mode...4

More information

Mist. now you know. Clock Radio with Weather Forecast. Quick Start Guide and User Manual

Mist. now you know. Clock Radio with Weather Forecast. Quick Start Guide and User Manual Mist Clock Radio with Weather Forecast Quick Start Guide and User Manual now you know. Contents 2 Welcome to Ambient Devices! 3 Quick Start Guide 5 Getting to know your Mist Clock Radio 8 Using your Mist

More information

KanAtoN 1 / 3 AIS Transponder. Installation Manual

KanAtoN 1 / 3 AIS Transponder. Installation Manual Orolia S.A.S. Z.I. des Cinq Chemins 56520 GUIDEL - FRANCE Telephone: +33 (0)2 97 02 49 49 Fax: +33 (0)2 97 65 00 20 Web : http://www.mcmurdomarinesystems.com An Orolia Group Business DATE : 20/072012 KanAtoN

More information

WPE 48N USER MANUAL Version1.1

WPE 48N USER MANUAL Version1.1 Version1.1 Security instructions 1. Read this manual carefully. 2. Follow all instructions and warnings. 3. Only use accessories specified by WORK PRO. 4. Follow the safety instructions of your country.

More information

BandMaster V Manual. Installation

BandMaster V Manual. Installation BandMaster V Manual Installation Installing and configuring the BM-5 BandMaster V is a simple process. All the configuration process is done from the front panel. Installation and configuration steps are

More information

Wireless Pressure Station

Wireless Pressure Station Wireless Pressure Station FORECAST RELATIVE PRESSURE PRESSURE HISTORY inhg -24h -18h -12h -9h- 6h -3h0 h INDOOR For online video support: http://bit.ly/laxtechtalk Model: 308-1417 DC: 111517 Table of Contents

More information

Atomic Forecast Station with Moon Phase

Atomic Forecast Station with Moon Phase Atomic Forecast Station with Moon Phase For online video support: http://bit.ly/laxtechtalk Model: S84107 Instruction Manual DC: 080817 Welcome to the La Crosse Technology family! We hope you enjoy your

More information

Always there to help you. Register your product and get support at AJ3200. Question? Contact Philips.

Always there to help you. Register your product and get support at  AJ3200. Question? Contact Philips. Always there to help you Register your product and get support at www.philips.com/support Question? Contact Philips AJ3200 User manual Contents 1 Important 2 Safety 2 2 Your clock radio 3 Introduction

More information

NTS-4000-S. NTS-4000-S Installation and Configuration Manual TEL: +44 (0) FAX: +44 (0) galleonsupport.

NTS-4000-S. NTS-4000-S Installation and Configuration Manual TEL: +44 (0) FAX: +44 (0) galleonsupport. NTS-4000-S Installation and Configuration Manual CONTENTS Contents... 2 Introduction... 4 Features... 4 What should be shipped... 5 Standard Parts... 5 Optional Parts... 5 Technical Specification... 6

More information

Radiodetection Pipeline Products

Radiodetection Pipeline Products Radiodetection Pipeline Products For efficient troubleshooting of cathodic protection systems on buried pipelines The Pipeline Range Pipeline Products Radiodetection is the world leader in the field of

More information

KiloStream Data Sheet

KiloStream Data Sheet KiloStream Data Sheet KiloStream speeds The choice of interfaces and speeds shown below enable a wide variety of equipment conforming to CCITT* standards to be connected. Speeds and interfaces Speed kbit/s

More information

Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual

Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual RMR183-e Cover R2 OP 1 Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor

More information

TPW288. Transmitter Transmission frequency: MHz Range of up to 50m Battery: 2 x AAA.UM04/LR03 (not included)

TPW288. Transmitter Transmission frequency: MHz Range of up to 50m Battery: 2 x AAA.UM04/LR03 (not included) . TPW288 FEATURES Radio controlled Clock DCF77 Automatic time signal receiving to display exact time with automatic winter/summer time change. Time format 12 or 24 hour format Time Zone setting from -12

More information

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308

ELSEMA 1,2,3,4,8 -Channel 433MHz GIGALINK Transmitter GLT43300,GLT43301,GLT43302,GLT43303,GLT43304,GLT43308 GLT43300/1/2/3/4/8 433MHz HAND HELD GIGALINK TRANSMITTERS Features One, two, three, four & eight channels. More than four billion code combinations and no dipswitch visible, enabling it to be used for

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information

SAPLING WIRELESS SYSTEM

SAPLING WIRELESS SYSTEM SAPLING WIRELESS SYSTEM Sapling Wireless System DESCRIPTION A Wireless Clock System starts with a master clock with a transmitter. The master clock s transmitter transmits the time data to the secondary

More information

3000W multi Pir light controller

3000W multi Pir light controller 3000W multi Pir light controller Cat No. MLB3000 - Black Cat No. MLW3000 - White Installation & Operating Instructions INSTALLATION & operating instructions SECTION ONE GENERAL INFORMATION The unit utilises

More information

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual

TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual TS-WS-07 Wireless Indoor/Outdoor 8-Channel Thermo-Hygrometer with Jumbo Display User Manual Table of Contents 1. Introduction......2 2.Getting Started.....2 2.1 Parts List.......2 2.2 Recommend Tools.........2

More information

200 RTH OFF ON IN OUT ALARM RESET

200 RTH OFF ON IN OUT ALARM RESET 200 RTH OFF ON IN OUT ALARM RESET EN OWNER S MANU AL www.auraton.pl 2 3 Thank you for purchasing the modern temperature controller based on an advanced microprocessor. AURATON 200 RTH LCD FrostGuard function:

More information

COD GB / 1.0 RBAND/UMS - RBAND/CSM

COD GB / 1.0 RBAND/UMS - RBAND/CSM INTRODUCTION DESCRIPTION The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge is used. The system provides a wireless system replacing

More information

R9999 ROBERTS. PLL Synthesised 3 band radio with station name display. Sound for Generations. Please read this manual before use

R9999 ROBERTS. PLL Synthesised 3 band radio with station name display. Sound for Generations. Please read this manual before use ROBERTS Sound for Generations R9999 PLL Synthesised 3 band radio with station name display Please read this manual before use Contents Important Information... 1 Automatic plug and play setup... 2 Controls...

More information

CONNECT SYSTEMS INCORPORATED 5321 Derry Ave., Suite B Agoura Hills, CA FLEX SERIES UNIVERSAL CONTROLLER

CONNECT SYSTEMS INCORPORATED 5321 Derry Ave., Suite B Agoura Hills, CA FLEX SERIES UNIVERSAL CONTROLLER CONNECT SYSTEMS INCORPORATED 5321 Derry Ave., Suite B Agoura Hills, CA 91301 Phone (805) 642-7184 Fax (805) 642-7271 FLEX SERIES UNIVERSAL CONTROLLER FLEX IIIA CTCSS COMMUNITY TONE PANEL User s Instruction

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock MAIN FEATURES: MAIN UNIT GB MODEL: RMR182 USER'S MANUAL INTRODUCTION Congratulations on your purchase of the RMR182 Multi- Channel In-Out

More information

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual

IDA 4 XM V 1.X. Installation and configuration of IDA 4 XM User Manual IDA 4 XM V 1.X Installation and configuration of IDA 4 XM User Manual IMPORTANT SAFETY INSTRUCTIONS - Switch the device s power off before any maintenance operation (changing the CU card, etc.) - The 24V

More information

TPW899. Package Contents. Technical Details

TPW899. Package Contents. Technical Details . TPW899 Thank you for purchasing this Ytora device. Please read these operating instructions carefully to familarize yourself with the features and modes of operation before using the instrument. Package

More information

Primare A32 Amplifier User Guide

Primare A32 Amplifier User Guide > Primare A32 Amplifier User Guide i 0 Preface.pm7 1 > Preface COPYRIGHT AND ACKNOWLEDGMENTS Copyright 2005 Primare Systems AB. All rights reserved. Primare Systems AB Renvägen 1 SE-352 45 Växjö Sweden

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

RCU-06 USER MANUAL. Introduction

RCU-06 USER MANUAL. Introduction RCU-06 USER MANUAL Introduction The following manual will show the features and how to use the new antenna electronic controller. As you will see, it is by far the most simple and intuitive controller

More information

Short form User Manual

Short form User Manual Nortech Detection Pty Ltd Unit1, Bldg 5, Forest Central Business Park, 49 Frenchs Forest Road, Frenchs Forest NSW 2086 PO Box 6011, Frenchs Forest DC, NSW 2086 Tel: 02 8977 4047 Fax: 02 9475 4742 email:

More information

i. AM. Radio Transmitter Installation and Operation Easy to follow instructions on how to program and use your Model 5.0 i. AM.

i. AM. Radio Transmitter Installation and Operation Easy to follow instructions on how to program and use your Model 5.0 i. AM. i. AM. Radio Transmitter Installation and Operation Easy to follow instructions on how to program and use your Model 5.0 i. AM. Radio Transmitter Contents Quick Start...3 Front and Rear Panel Controls...5

More information

10/17/2011. I have an Air-Card. I have Satellite Internet. Why would I use Wi-Fi? Just for

10/17/2011. I have an Air-Card. I have Satellite Internet. Why would I use Wi-Fi? Just for How much do you use the Internet? Just for e-mail Or. 2011 National HDT Rally How much do you use the Internet? How much do you use the Internet? E-mail Face Book Google Plus Blog reading Blog Writing

More information

3000W MULTI PIR LIGHT CONTROLLER

3000W MULTI PIR LIGHT CONTROLLER 3000W MULTI PIR LIGHT CONTROLLER Cat No. MLB3000 Black Cat No. MLW3000 White Installation & Operating Instructions INSTALLATION & OPERATING INSTRUCTIONS E G Dusk/Dawn Time Override/Holiday Mode F H Lens

More information

LK Wireless Room Control Cq

LK Wireless Room Control Cq LK Wireless Room Control Cq Description LK Wireless Room Control Cq consists of a LK Room Thermostat Cq-n (transmitter) and a LK Receiver Unit Cq 8 (8 channel receiver unit). The range also includes a

More information

n FRONT PANEL CONFIGURATIONS

n FRONT PANEL CONFIGURATIONS INSTRUCTION MANUAL VALVE POSITIONER (for LonWorks; built-in SSR) MODEL MEXL MEXL BEFORE USE... Thank you for choosing M-System. Before use, check the contents of the package you received as outlined below.

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No ALTHC015 RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 2 2 ALTHC015 INSTRUCTION

More information

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR 1. Introduction The FLUX 11 is a single channel plug-in inductive loop detector designed for vehicle access applications, and interfaces

More information

SpeedTouch 190. Setup and User s Guide. SIP Gateway. Release R1.0

SpeedTouch 190. Setup and User s Guide. SIP Gateway. Release R1.0 SpeedTouch 190 SIP Gateway Setup and User s Guide Release R1.0 SpeedTouch 190 Setup and User s Guide Release R1.0 Status v1.0 Reference E-DOC-CTC-20040401-0004 Short Title Setup and User s Guide ST190

More information

Model: WS-7014CH-IT Instruction Manual DC: WIRELESS FORECAST STATION

Model: WS-7014CH-IT Instruction Manual DC: WIRELESS FORECAST STATION Model: WS-7014CH-IT Instruction Manual DC: 081815 WIRELESS FORECAST STATION Date Time + WWVB Indoor Temperature, Humidity + Comfort Forecast + Tendency Outdoor Temperature ºF/ºC + Channel Indicator Base

More information

RF4432 wireless transceiver module

RF4432 wireless transceiver module 1. Description www.nicerf.com RF4432 RF4432 wireless transceiver module RF4432 adopts Silicon Lab Si4432 RF chip, which is a highly integrated wireless ISM band transceiver. The features of high sensitivity

More information

KRONOsync Transmitter System Operations Guide

KRONOsync Transmitter System Operations Guide KRONOsync Transmitter 11869 Teale St. Culver City, CA 90230 Tech Support: 888-608-0125 www.innovationwireless.com Thank You for Purchasing the KRONOsync GPS/NTP Wireless Clock System from. We appreciate

More information

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing

More information

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS FULL FEATURED SATELLITE CLOCK TCG 02-G The TCG 02-G is a highly accurate, full featured GPS and GLONASS (GNSS) clock. Offering multiple oscillator options, Time Code and Frequency outputs, it fits virtually

More information

RFS 2. Operating instructions Bedienungsanleitung Mode d emploi

RFS 2. Operating instructions Bedienungsanleitung Mode d emploi RFS 2 Operating instructions Bedienungsanleitung Mode d emploi scope OF delivery 1 11 3 10 2 12 4 5 6 7 8 9 1 case 2 lithium button cell li-mn cr2450 (560 mah, 3 V) 3 display 4 usb socket 5 Sync in 6 Sync

More information

With Audible Detect Signal

With Audible Detect Signal T-100 SERIES SINGLE CHANNEL SHELF MOUNT DETECTOR Meets and exceeds NEMA TS 1 specification. Six front panel DIP switches provide: Seven levels of sensitivity plus off. Presence or Pulse mode. Four loop

More information

Important Safety Information

Important Safety Information OWNER'S MANUAL Important Safety Information 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only

More information

Instruction Manual REMOTE CONTROL BOX OM3500 A. OM POWER, s. r. o Báč 126 SLOVAKIA

Instruction Manual REMOTE CONTROL BOX OM3500 A. OM POWER, s. r. o Báč 126 SLOVAKIA Instruction Manual REMOTE CONTROL BOX OM3500 A OM POWER, s. r. o. 930 30 Báč 126 SLOVAKIA General description of the OM 3500 A Remote control Remote Control expands possibilities of using OM3500 A up to

More information

RadioStar INTRODUCTION

RadioStar INTRODUCTION CONTENTS INTRODUCTION...2 PACK CONTENTS...2 SAFETY INSTRUCTIONS...3 DEFINITION OF SYMBOLS...4 RECOMMENDED TOOLS...4 ASSEMBLY INSTRUCTIONS...5 RADIOSTAR MIRROR FUNCTIONS...7 SIDE INTEGRATED CONTROL PANEL...8

More information

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series OPERATION MANUAL INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series VOICE ALARM SYSTEM AMPLIFIER VM-3240VA VOICE ALARM SYSTEM AMPLIFIER VM-3360VA VM EXTENSION AMPLIFIER VM-3240E VM EXTENSION AMPLIFIER VM-3360E

More information

CSI MasterFormat Specification. Wireless Remote Transmitter

CSI MasterFormat Specification. Wireless Remote Transmitter Specification Wireless Remote Transmitter SSQRTM-CSI-Spec Rev. 3 July 2015 This product specification is written according to the Construction Specifications Institute (CSI), MasterFormat, SectionFormat,

More information

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS FULL FEATURED SATELLITE CLOCK TCG 02-G The TCG 02-G is a highly accurate, full featured GPS and GLONASS (GNSS) clock. Offering multiple oscillator options, Time Code and Frequency outputs, it fits virtually

More information

ELSEMA 1,2,3,4,8 -Channel 433MHz,25mWatt Transmitter

ELSEMA 1,2,3,4,8 -Channel 433MHz,25mWatt Transmitter ELSEMA GLT4330112E, GLT4330212E, GLT4330412E, GLT4330812E, GLT4330812NC 433MHz, 25mW GIGALINK TRANSMITTERS Features One, two, four & eight channels. Wide supply connection 11.0 to 24.0 Volts DC. More than

More information

ATOMIC WALL CLOCK with REMOTE TEMPERATURE SENSOR Model CL Instruction Manual

ATOMIC WALL CLOCK with REMOTE TEMPERATURE SENSOR Model CL Instruction Manual ATOMIC WALL CLOCK with REMOTE TEMPERATURE SENSOR Model CL030027 Instruction Manual Congratulations on purchasing your ATOMIC CLOCK with REMOTE TEMPERATURE SENSOR. Please read these instructions carefully

More information

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual USL300 SNOW DEPTH SENSOR Revision 1.1.2 User Manual 1 Table of Contents 1. Introduction... 3 2. Operation... 3 2.1. Electrostatic Transducer... 4 2.2. SL300 Analog Board... 4 2.3. SL300 Digital Circuit

More information

Industriefunkuhren. Technical Manual. System 7001RC. Multi-Source Function ENGLISH. Version:

Industriefunkuhren. Technical Manual. System 7001RC. Multi-Source Function ENGLISH. Version: Industriefunkuhren Technical Manual System 7001RC Multi-Source Function ENGLISH Version: 02.01-29.11.2006 Valid for Control Board 7020RC with FIRMWARE Version: 01.00 and REMOTE-SOFTWARE Version: 00.00

More information