1 ECDA to assess possibility of AC Corrosion Mark Yunovich Honeywell Corrosion Solutions January 27 th, 2009
2 What are we talking about today? Assessing the degree of AC interference at the pipeline level - What can one do using ECDA tools to assess the likelihood of AC corrosion - Commonly used criteria Based on current density, not voltage (<20/30, >100 A/m 2 ) - Defining regions? Coating condition (defect sizing) Soil resistivity/depth of cover - Which tools? AC CIS Direct current measurement (CTS) Modeling - Direct Assessment Morphology of damage Not talking about protection criteria (i.e., how much CP is necessary to offset the AC interference) - Still debated - Concern about overprotection Not talking about mitigation
3 Introduction PHMSA-sponsored research The primary focus was ECDA aboveground assessment with emphasis on: DCVG, CIS accuracy with and without interference March 2008 Unique conditions AC corrosion threat assessment
4 Assessing AC Corrosion: AC CIS and what else? Some algebra Laboratory experimental modeling PRCI software assessment Full-scale outdoor testing - Utilized a large scale outdoor facility: multiple sections of coated pipeline, spanning a total of 120 feet internal diameter of 20 inches and an external FBE coating
5 AC CIS Commonly employed technique of assessing the problem AC CIS measurements: AC voltage on the pipe is measured AC voltage can be used to make an approximate calculation of the current density expected for a defect of a known (or assumed size)
6 Experimental site 3 ft sections of pipeline have waterproof end seals Each section contains an intentionally introduced defect - Defects range from 1 to 10 sq.in in area - Circumferential position (2, 3, 9, and 12 o clock) - Contains bare sections - Lateral spacing (2.5 to 5 ft) - Different depth of cover - Different resistivities
7 Experimental site
8 Experimental site HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 8
9 Experimental site
10 AC CIS Laboratory measurements 12:00 or 6:00 12:00 12:00
11 AC CIS - calculations Converting AC voltage into current density - i AC current density (A/m 2 ) - U measured AC voltage (V) - R resistance (ohm) - A assumed or known area of bare metal (m 2 ) R is a spread resistance - circular holiday with diameter d, - resistance of the coating ( pore resistance) - s and f soil and electrolyte resistance - h pore (coating) thickness i R U R s A 4 2d d 2 f h
12 AC CIS - calculations Converting AC voltage into current density Assuming that s = f ; at larger holiday sizes (d 4 h s f R i 2 2d d and substituting h), 8V AC d where: i = AC current density V AC = AC voltage of pipeline to remote earth s = soil resistivity d = diameter of a circular holiday having an area equal to that of the actual holiday
13 AC density, A/sq.m AC CIS - calculations Resistance, ohm AC density, A/sq.m Resistance, ohm Converting AC voltage into current density Density Calculated Resistance 1.00E E E Density Calculated Resistance 1.00E E E E E E E E E E E E E E E E Defect size, cm Lower resistivity i 8V E Defect size, cm AC d Higher resistivity Defect size dominates pore resistance at sizes greater than 1 cm HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 13
14 AC density, A/sq.m AC CIS - calculations Converting AC voltage into current density Influence of soil resistivity on current density is diminished (from practical point of view) as holiday size increases K ohm-cm 500 ohm-cm is 40:1 for all defect sizes, however: For larger defects densities stay under 10A/m 2 for 1000 ohm-cm and above AC voltage fixed at 5V Soil resistivity, ohm-cm HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 14
15 AC density, A/sq.m AC CIS - calculations Converting AC voltage into current density Current density is greater than 50A/m 2 : for AC voltage of as small as 10V cm defect for AC voltage as low as 1V 1 cm defect 10 soil resistivity is fixed at 5,000 ohm-cm AC Voltage HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 15
16 Volts, AC AC CIS - laboratory Converting AC voltage into current density - AC Voltage 4.5V - Clay resistivity 90 ohm-cm - Sand resistivity 74,000 ohm-cm Distance, in Defect 1 Defect 2 Defect 3 AC density, A/m 2 Estimated Measured Error % % %
17 AC CIS - laboratory PRCI model Includes comprehensive electromagnetic coupling equations - with an interface format to enable both steady state and fault induced voltages and currents to be calculated Was not expressly made for predicting AC currents - inner logic could not be modified (it estimates coating condition by multiplying the soil resistivity by a certain coefficient) - a number of assumptions had to be made to accommodate the requirements.
18 AC CIS - laboratory PRCI model Inputs: Location AC current measured, (ma) Impedance, ohm Defect 1 (clay) 4" Defect 3 (sand) 14" Scaling factor had to be employed (1200:1) Coating condition Current, ma Defect 1 Defect 3 Fair Good Excellent Superior Flawless
19 AC CIS - laboratory PRCI model So? - Low resistivity soil consistently higher currents - Coating degrades low current from defect - Defect in sand soil resistivity dominates, even for poor ( fair ) coating condition Coating condition Current, ma Defect 1 Defect 3 Fair Good Excellent Superior Flawless
20 AC CIS - laboratory And? Knowledge of soil resistivity is absolutely critical for AC CIS approach - adjacent soils (sand and clay) can have two drastically different resistivities - Low resistivity (high discharge) margin of error - minimal - High resistivity - dramatically different calculation errs on the side of underestimation of the AC current density. measured density, which is more than 10 times greater, has been demonstrated to cause accelerated corrosion of buried steel
21 AC CIS - Large-scale AC voltage, V 2.5 With AC signal Without AC signal 2 #1-#10 (no AC) #1-# Distance, feet
22 AC density, A/sq.m AC CIS Large-scale Calculated current density CD (actual) Average (calculated) Effective defect size, cm Actual current density HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 22
23 AC CIS Large-scale Less than ideal correlation - Reasonable trend /within an order of magnitude - AC CIS values are lower than actual values - Probable inaccuracy bulk resistance vs. actual resistance of the holiday Smaller sized defects have higher discrepancy Geometry and soil/metal interface properties may dominate bulk resistivity HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 23
24 Coupon Test Stations Frequently used - Permanent - Temporary - Can be used for corrosion rate measurements Issue of how long to expose Literature suggests as long as 1 year Can be used to measure spot AC voltage Large scale facility - 4 CTS - Coupon size approximately 9 cm 2 HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 24
25 Coupon Test Stations 1000% 100% Actual/CTS Holiday only/h+cts 1. Holiday only vs. Holiday plus CTS 2. Actual vs. Calculated current density from CTS AC voltage 10% 1% Effective defect size, cm Adding CTS coupon to a small holiday produces greater error Calculations of current density are more conservative (over-estimation) when connected to large area of bare metal 1 measure of what happens when exposed area is increased 2 measure of how accurate calculated current density is when CTS is connected to pipeline HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 25
26 Coupon Current Density (Amperes/Meter Squared) Coupon Current Density (Amperes/Meter Squared) Coupon Test Stations When/how long to monitor using coupons - Spot-checks vs. data recording Typical time of Day Technician Takes Reading Jul 14-Jul 15-Jul 15-Jul 15-Jul 15-Jul 16-Jul 16-Jul 16-Jul 16-Jul Jul 17-Jul 17-Jul 17-Jul /19 7/20 7/21 7/22 7/23 7/24 7/25 7/26 7/27 7/28 7/29 7/30 7/31 8/1 8/2 8/3 8/4 8/5 8/6 8/7 8/8 8/9 8/10 8/11 8/12 8/13 HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 26
27 AC Corrosion above-ground assessment Commercially available probes - MetriCorr (Denmark, - ER probe - Collects data on corrosion rate, AC current and voltage and spread resistance - Measures DC current and potential
28 AC Corrosion above ground assessments Assessments of AC current density via AC CIS can be attempted and provide order of magnitude estimates Use of equations requires accurate knowledge of defect sizes and resistivities - Can be overly conservative or not conservative enough - Do assessments at multiple locations Use of CTS is helpful - Provides a more accurate estimate of current density - Select coupon sizes carefully - Multiple locations - Data collection interval is important ER probe commercially available HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 28
29 AC Corrosion Direct Examination Whither AC Corrosion? Consider the circumstances Eliminate the usual suspects (Occam s razor principle) Certain morphological signatures - Hard, domed-shape cluster of soil and corrosion products - Isolated or grouped pitting HONEYWELL INTERNATIONAL, INC. All rights reserved 11 February 2009 Slide 29
30 AC Corrosion Direct Examination
31 AC Corrosion ECDA takeaways Not easy - Probabilistic assessment - Criteria not completely agreed upon Segmentation similar to DC ECDA - Includes consideration of interference - Coating conditions - Resistivity/resistance issues Above-ground methods are few - AC CIS - Spot measurements - CTS - Probes Direct examination - Eliminate other causes - Consider CP levels - Consider morphology
32 Questions?
AC Voltage- Pipeline Safety and Corrosion MEA 2015
AC Voltage- Pipeline Safety and Corrosion MEA 2015 WHAT ARE THE CONCERNS ASSOCIATED WITH AC VOLTAGES ON PIPELINES? AC concerns Induced AC Faults Lightning Capacitive coupling Safety Code Induced AC Corrosion
More informationENGINEERING REPORT PHASES I & II MITIGATOR PERFORMANCE TESTS
ENGINEERING REPORT PHASES I & II MITIGATOR PERFORMANCE TESTS INDUCED AC MITIGATION PERFORMANCE ON A STEEL GAS TRANSMISSION PIPELINE REPORT OF JANUARY 29, 2014 Copyright MATCOR, Inc. 2014 MITIGATOR TM VS.
More informationPIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES
Fact File No 1 PIPELINE CORROSION RISKS ASSOCIATED WITH AC VOLTAGES Cathodic Protection Co Ltd INTRODUCTION This document discusses corrosion that is believed to be caused by AC current flowing from (i.e.
More informationExamples of Design for Cathodic Protection Systems
Examples of Design for Cathodic Protection Systems CURRENT REQUIREMENTS From Estimated Exposed Surface Area Estimating current requirements from expected exposed surface is always subject to error. There
More informationOVERCOMING THE NEW THREAT TO PIPELINE INTEGRITY - AC CORROSION ASSESSMENT AND ITS MITIGATION -
23rd World Gas Conference, Amsterdam 2006 OVERCOMING THE NEW THREAT TO PIPELINE INTEGRITY - AC CORROSION ASSESSMENT AND ITS MITIGATION - Main author Y. Hosokawa JAPAN ABSTRACT AC corrosion risk on gas
More informationStatic Stray DC Current Interference Testing
Static Stray DC Current Interference Testing Period 6 Intermediate Corrosion Course 2017 February 21-23, 2017 Mike Placzek ARK Engineering 1 February 21-23, 2017 Mike Placzek ARK Engineering 2 Agenda What
More informationAboveground Monitoring - Casings Long Range Electromagnetic Wave (EMW) Inspection
Aboveground Monitoring - Casings Long Range Electromagnetic Wave (EMW) Inspection Period 7 Pipeline Coatings Course 2017 February 21-23, 2017 John DeWees, CEO WaveTrue 2017 1 Electromagnetic Wave Inspection
More informationMonitoring DC Decoupling Devices at Isolation Flanges for Compliance and Pipeline Integrity
Monitoring DC Decoupling Devices at Isolation Flanges for Compliance and Pipeline Integrity Jamey Hilleary Director of M2M Products Elecsys Corporation Jerry Dewitt Senior Cathodic Protection Specialist
More information1 Comparison of Approaches (SESTLC, ROW & HIFREQ) for AC Interference Study
1 Comparison of Approaches (SESTLC, ROW & HIFREQ) for AC Interference Study 1 Comparison of Approaches (SESTLC, ROW & HIFREQ) for AC Interference Study 1.1 Introduction Yexu Li and Simon Fortin Three independent
More informationEMW-C and EMW-I NDT for Annulus and Internal Pipe Inspection
EMW-C and EMW-I NDT for Annulus and Internal Pipe Inspection WaveTrue Science + Technologies 504 El Paraiso Rd NE Albuquerque, NM 87113 CEO Ron Floit President John DeWees (888) 711-2532/ (212) 625-6622
More information(IDC) INTEGRATED DATA COLLECTION TECHNOLOGY. Presented by: Kevin Pastotnik
(IDC) INTEGRATED DATA COLLECTION TECHNOLOGY Presented by: Kevin Pastotnik Definition and Brief History to the Need INTEGRATED DATA COLLECTION TECHNOLOGY What is IDC? IDC is an external assessment tool
More informationPipeline Research Council International, Inc.
Pipeline Research Council International, Inc. Technology Development for Pipeline Integrity Current Features & Coming Attractions API 2012 Pipeline Conference & Cybernetics Symposium Phoenix, AZ April
More informationApplying Advanced Assessment Methodologies and Guided Wave Testing (GWT) on Difficult to Assess Segments
Applying Advanced Assessment Methodologies and Guided Wave Testing (GWT) on Difficult to Assess Segments Larry Legendre Williams Supervisor, Asset Integrity Center of Excellence (713) 215-2733 Larry.D.Legendre@Williams.com
More informationElectrical TP-18 February 2017 ELECTRICAL TECHNICAL PAPER 18 FREQUENTLY ASKED QUESTIONS ABOUT CATHODIC PROTECTION SYSTEM EQUIPMENT TESTING
ELECTRICAL TECHNICAL PAPER 18 FREQUENTLY ASKED QUESTIONS ABOUT CATHODIC PROTECTION SYSTEM EQUIPMENT TESTING CATHODIC PROTECTION SYSTEM EQUIPMENT TESTING Question No. 1 What should I (the contractor) check
More informationGeneral Consideration about Current Distribution and Potential Attenuation Based on Storage Tank Bottom Modeling Study
C2012-0001155 General Consideration about Current Distribution and Potential Attenuation Based on Storage Tank Bottom Modeling Study Jean Vittonato TOTAL E&P CONGO Pointe Noire Republic of Congo Jean.vittonato@total.com
More informationACCURATE SIMULATION OF AC INTERFERENCE CAUSED BY ELECTRICAL POWER LINES: A PARAMETRIC ANALYSIS
ACCURATE SIMULATION OF AC INTERFERENCE CAUSED BY ELECTRICAL POWER LINES: A PARAMETRIC ANALYSIS J. Liu and F. P. Dawalibi Safe Engineering Services & technologies ltd. 1544 Viel, Montreal, Quebec, Canada
More informationCIPS, DCVG & GPCM Pipeline Surveyor. Corrosion Control Equipment
CIPS, DCVG & GPCM Pipeline Surveyor Corrosion Control Equipment Electronic Pipeline Technology 153 Milos Road Richmond Hill, Ontario, Canada, L4C 0P8 Tel: (905) 918-0025 Fax: (905) 918-0033 www.ep-tech.ca
More informationDCVG Coating Survey Data Sheet
DCVG Coating Survey Data Sheet DCVG COATING DEFECT SURVEYS Today, DC voltage gradient surveys have evolved as an accurate and economic means of locating coating defects. When a DC current is applied to
More informationAnalysis of the Electromagnetic Interferences between Overhead Power Lines and Buried Pipelines
Mediterranean Journal of Modeling and Simulation MJMS 1 (214) 13 23 Analysis of the Electromagnetic Interferences between Overhead Power Lines and Buried Pipelines M hamed Ouadah a*, Mourad Zergoug b a
More informationDetection of Protective Coating Disbonds in Pipe Using Circumferential Guided Waves
17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Detection of Protective Coating Disbonds in Pipe Using Circumferential Guided Waves Jason K. Van Velsor Pennsylvania State
More informationBasic Measurements for Pipe Inspections
Basic Measurements for Pipe Inspections Period 7 Basic Corrosion Course 2017 February 21-23, 2017 Mark Anderson-MTS 1 DOT 192.459 External corrosion control: Examination of buried pipeline when exposed.
More informationfrom ocean to cloud LAND CABLE INTERFERENCE MODEL AND CABLE CROSSINGS WITH POWER INTERCONNECTS
LAND CABLE INTERFERENCE MODEL AND CABLE CROSSINGS WITH POWER INTERCONNECTS Mr. Ritesh Dass (Cable&Wireless Worldwide) Email: ritesh.dass@cw.com Cable&Wireless Worldwide, 32-43 Chart Street, London, N1
More informationTesting of Buried Pipelines Using Guided Waves
Testing of Buried Pipelines Using Guided Waves A. Demma, D. Alleyne, B. Pavlakovic Guided Ultrasonics Ltd 16 Doverbeck Close Ravenshead Nottingham NG15 9ER Introduction The inspection requirements of pipes
More informationPipeline Current Mapper
Pipeline Current Mapper Locate Accurately find buried pipes, establish centerline depth, then troubleshoot coating defects Record Stores up to 1000 measured PCM and location data in memory within the receiver
More informationWell Casing Cathodic Protection - Design Issues, Lessons Learned and a Case History
Well Casing Cathodic Protection - Design Issues, Lessons Learned and a Case History Jeffrey L. Didas Matcor, Inc. 101 Liberty Lane Chalfont, PA 19111 USA WRGC Western Regional Gas Conference 2018 Henderson,
More informationElectric Power Systems Research
Electric Power Systems Research 94 (2013) 54 63 Contents lists available at SciVerse ScienceDirect Electric Power Systems Research j ourna l ho me p a ge: www.elsevier.com/locate/epsr Calculation of overvoltage
More informationpipeline integrity PCM + Pipeline Current Mapper
pipeline integrity PCM + Pipeline Current Mapper Fast locate and effective measurement of pipeline coating defects. The location and measurement of pipeline corrosion using electromagnetic detection devices
More informationAC Interference Corrosion, Corrosive Soil, Design Issues, Zinc Ribbon and Corrosion Mitigation
Paper No. 12828 AC Interference Corrosion, Corrosive Soil, Design Issues, Zinc Ribbon and Corrosion Mitigation Mehrooz Zamanzadeh, Peyman Taheri, and George T. Bayer Matergenics, Inc. 100 Business Center
More informationThe Isolator/Surge Protector (ISP) Technical Literature
The Isolator/Surge Protector (ISP) Technical Literature INTRODUCTION The Isolator/Surge Protector (ISP) is a solid-state device with logic-controlled circuitry which simultaneously provides DC isolation
More informationEarthing of Electrical Devices and Safety
Earthing of Electrical Devices and Safety JOŽE PIHLER Faculty of Electrical Engineering and Computer Sciences University of Maribor Smetanova 17, 2000 Maribor SLOVENIA joze.pihler@um.si Abstract: - This
More informationHigh Voltage Pylon Earth Measurements
High Voltage Pylon Earth Measurements Speaker: Gavin van Rooy Authors: Frank Barnes and Gavin van Rooy Tycom (Pty) Ltd PO Box 3546, Randburg, 2125, South Africa E-mail: frank@tycom.co.za Phone: 011 787
More informationGrounding and Lightning arrestors
CHAPTER - Four Grounding and Lightning arrestors 4.1. Introduction Electrical connection of neutral point of a supply system or the non current carrying part of electrical equipments to the general mass
More informationInstant-Off (I-O) Measurements on Decoupled Systems
Instant-Off (I-O) Measurements on Decoupled Systems Important Considerations What Is A Decoupler? A device that has a very low impedance to ac current but blocks the flow of dc current up to a predetermined
More informationCONTINUING EDUC ATION
3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com
More informationWhat Are We Protecting? Over-Voltage Protection for CP Systems. Personnel (primary) Equipment (secondary)
What Are We Protecting? Personnel (primary) Equipment (secondary) Over-Voltage Protection for CP Systems Personnel Protection: Touch Potential Personnel Protection: Step Potential Equipment Protection
More informationImportance of Grounding in Power System. Presented by Mr. H Jayakumar Ex- Joint Director CPRI
Importance of Grounding in Power System Presented by Mr. H Jayakumar Ex- Joint Director CPRI OBJECT OF EARTHING Prime Object of Earthing is to Provide a Zero Potential Surface in and around and under the
More informationThe Isolator/Surge Protector (ISP)
The Isolator/Surge Protector (ISP) Technical Literature INTRODUCTION The Isolator/Surge Protector (ISP) is a solid-state device with logic-controlled circuitry which simultaneously provides DC isolation
More informationThe Isolator/Surge Protector (ISP)
The Isolator/Surge Protector (ISP) Technical Literature INTRODUCTION The Isolator/Surge Protector (ISP) is a solid-state device with logic-controlled circuitry which simultaneously provides isolation and
More informationINTEGRATED METHOD IN ELECTROMAGNETIC INTERFERENCE STUDIES
INTEGRATED METHOD IN ELECTROMAGNETIC INTERFERENCE STUDIES Jinxi Ma and Farid P. Dawalibi Safe Engineering Services & technologies ltd. 1544 Viel, Montreal, Quebec, Canada, H3M 1G4 Tel.: (514) 336-2511
More informationTitle of Innovation: In-Line Inspection for Water Pipelines
Title of Innovation: In-Line Inspection for Water Pipelines Nominee(s) Margaret Hannaford, P.E., Division Manager, Hetch-Hetchy Water and Power Division of the San Francisco Public Utilities Commission
More information7. Consider the following common offset gather collected with GPR.
Questions: GPR 1. Which of the following statements is incorrect when considering skin depth in GPR a. Skin depth is the distance at which the signal amplitude has decreased by a factor of 1/e b. Skin
More informationTechnical Seminar for Cathodic Protection to GOGC Design Unit Specialists. Dr. Nick Kioupis, Cathodic & Lightning Protection Section Head, DESFA
Technical Seminar for Cathodic Protection to GOGC Design Unit Specialists Dr. Nick Kioupis, Cathodic & Lightning Protection Section Head, DESFA Photo of a typical T/R cabinet Impressed current stations
More informationGuided Wave Testing - Maximizing Buried Pipe Corrosion Knowledge from each Excavation
Proceedings of the ASME 2012 Pressure Vessels & Piping Conference PVP2012 July 15-19, 2012, Toronto, Ontario, CANADA PVP2012-78561 Guided Wave Testing - Maximizing Buried Pipe Corrosion Knowledge from
More informationMeasuring Circumferential Metal Loss Rates in Subsea Pipelines
Measuring Circumferential Metal Loss Rates in Subsea Pipelines Presented by Dan Clarke 7 December 2012 1 Contents Introduction to Corrosion Monitoring RPCM Technology Overview Measurement Performance Case
More informationOverview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.
Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E. HP Critical Facility Services delivered by EYP MCF What is VOLTAGE? Difference of Electric Potential
More informationIndustrial and Commercial Power Systems Topic 7 EARTHING
The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 7 EARTHING 1 INTRODUCTION Advantages of earthing (grounding): Limitation
More information60Hz Ratings. Typical Applications. Features & Characteristics. Ratings
The PCR is a solid-state device designed to simultaneously provide DC isolation and AC continuity/grounding when used with cathodically protected structures, such as pipelines, tanks, grounding systems,
More informationHigh Voltage Pylon earth Measurements. Tycom (Pty) Ltd Frank Barnes Comtest (Pty) Ltd Presented by Gavin van Rooy
High Voltage Pylon earth Measurements Tycom (Pty) Ltd Frank Barnes Comtest (Pty) Ltd Presented by Gavin van Rooy Abstract The earth connection of high voltage electrical power line pylons is obviously
More informationPipeline Inspection Technologies Demonstration Report Final
University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln United States Department of Transportation -- Publications & Papers U.S. Department of Transportation 26 Pipeline Inspection
More informationRELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK
RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK The Guided wave testing method (GW) is increasingly being used worldwide to test
More informationAcoustic Emission Linear Location Cluster Analysis on Seam Welded Hot Reheat Piping
Acoustic Emission Linear Location Cluster Analysis on Seam Welded Hot Reheat Piping The EPRI Guidelines for acoustic emission (AE) inspection of seamed hot reheat piping were published in November 1995.
More informationIMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES USING REMOTE FIELD EDDY CURRENT
12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES
More informationElectronic Pipeline Technology
Pipe and Cable Locator Pearson Holiday Detector Model EPT- 1000 Electronic Pipeline Technology Electronic Pipeline Technology 26 Palomino Drive, Richmond Hill, Ontario, Canada, L4C 0P8 Tel: (905) 918-0025
More informationPulse Arrested Spark Discharge (PASD) Wiring Diagnostic**
8 th Joint FAA/DoD/NASA Conference on Aging Aircraft February, 5 Pulse Arrested Spark Discharge (PASD) Wiring Diagnostic** Larry X Schneider *, M. Dinallo, R. K. Howard, S. F. Glover, G. E. Pena **, T.
More informationLinear Polarisation Noise for Corrosion Monitoring in Multiple Phase Environments. (Patent Pending)
ACM Instruments Linear Polarisation Noise for Corrosion Monitoring in Multiple Phase Environments. (Patent Pending) Linear Polarisation Resistance Noise gives two results: the average monitored corrosion
More informationICCP Retrofit Challenges for an Offshore Jacket Complex
Paper No. 6012 ICCP Retrofit Challenges for an Offshore Jacket Complex Christophe Baeté, CP Manager Elsyca n.v. Vaartdijk 3/603, 3018 Wijgmaal, Belgium christophe.baete@elsyca.com ABSTRACT An offshore
More informationEARTH-POTENTIAL ELECTRODES PERMAFROST AND TUNDRA
EARTH-POTENTAL ELECTRODES PERMAFROST AND TUNDRA N V. P. Hessler and A. R. Franzke* ntroduction URNG the past two years the authors installed a number of electrodes D in the permafrost and tundra area of
More informationDetection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT)
Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT) Author: Ankit Vajpayee Russell NDE Systems Inc. 4909 75Ave Edmonton, Alberta, Canada T6B 2S3 Phone 780-468-6800
More informationDCVG Training Manual DA Meter Version
DC-Voltage Gradient (DCVG) Surveys Using MCM s Integrated Pipeline Survey Test Equipment and Database Management Package DCVG Training Manual DA Meter Version M. C. Miller Co., Inc. 11640 US Hwy 1, Sebastian,
More informationDynatel 2250E/2273E Advanced Cable and Fault Locator
Dynatel 2250E/2273E Advanced Cable and Fault Locator Operators Manual September 1999 78-8097-6500-7-B TABLE OF CONTENTS Introduction... 2 Installing or Replacing the Batteries... 2 Initial Receiver Configuration...
More informationUsing Remote Data-Logging Techniques to Evaluate Transit System Interference
Using Remote Data-Logging Techniques to Evaluate Transit System Interference Jamey Hilleary Director of M2M Products Elecsys Corporation Jerry Dewitt Senior Cathodic Protection Specialist Enbridge Pipelines
More informationDevice Interconnection
Device Interconnection An important, if less than glamorous, aspect of audio signal handling is the connection of one device to another. Of course, a primary concern is the matching of signal levels and
More informationExhibit DD Specific Standards for Transmission Lines. Boardman to Hemingway Transmission Line Project
Specific Standards for Transmission Lines Boardman to Hemingway Transmission Line Project West Idaho Street Boise, Idaho 0 Mark Stokes, Project Leader Zach Funkhouser, Permitting (0) - (0) - mstokes@idahopower.com
More informationPRACTICAL ENHANCEMENTS ACHIEVABLE IN LONG RANGE ULTRASONIC TESTING BY EXPLOITING THE PROPERTIES OF GUIDED WAVES
PRACTICAL ENHANCEMENTS ACHIEVABLE IN LONG RANGE ULTRASONIC TESTING BY EXPLOITING THE PROPERTIES OF GUIDED WAVES PJ Mudge Plant Integrity Limited, Cambridge, United Kingdom Abstract: Initial implementations
More information1. Introduction to Power Quality
1.1. Define the term Quality A Standard IEEE1100 defines power quality (PQ) as the concept of powering and grounding sensitive electronic equipment in a manner suitable for the equipment. A simpler and
More informationFall-Of-Potential Calculations Using MALZ
Fall-Of-Potential Calculations Using MALZ by Greg Chang Pacific Gas & Electric Company, California, USA As a means to check the validity of the soil and ground grid model used in a grounding analysis study,
More informationGround-Mounted Verticals. Dispelling the Myths and Misconceptions
Dispelling the Myths and Misconceptions Let s start with a quiz on vertical antennas and radials. Answers will be there to discover, as we proceed through the presentation. To be most effective, a ground-mounted
More informationThe Essentials of Pipeline Integrity Management
TRAINING METHODOLOGY This interactive training workshop includes the following training methodologies : Lectures Video Discussion of case histories and hands on calculations WHO SHOULD ATTEND The course
More informationDevelopments in Ultrasonic Guided Wave Inspection
Developments in Ultrasonic Guided Wave Inspection Wireless Structural Health Monitoring Technology for Heat Exchanger Shells using Magnetostrictive Sensor Technology N. Muthu, EPRI, USA; G. Light, Southwest
More informationWESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)
WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868) THREE-PHASE SUBSURFACE UNDERGROUND COMMERCIAL DISTRIBUTION (UCD) TRANSFORMER NOTE: This "Guide" summarizes the opinions, recommendations, and practices
More informationEXAMINATION OF TIME DOMAIN REFLECTOMETRY FOR FAULT LOCATING IN PIPELINES
EXAMINATION OF TIME DOMAIN REFLECTOMETRY FOR FAULT LOCATING IN PIPELINES Abstract Christoph von der Ahe, Ludger Overmeyer Institut für Transport und Automatisierungstechnik Leibniz Universität Hannover
More informationRadiodetection Pipeline Products
Radiodetection Pipeline Products For efficient troubleshooting of cathodic protection systems on buried pipelines The Pipeline Range Pipeline Products Radiodetection is the world leader in the field of
More informationSECTION TRACER WIRE FOR NONMETALLIC PIPE
PART 1 GENERAL 1.1 DESCRIPTION A. The CONTRACTOR shall furnish and install a conductive tracer wire with all buried plastic water mains, services and appurtenances in accordance with the Water Utilities
More informationOperation Manual for CTL-3000
CATH-TECH CORROSION CONTROL EQUIPMENT Operation Manual for CTL-3000 DCVG Survey Instrument Cathodic Technology Ltd. 15-1 Marconi Court Bolton, Ontario Canada L7E 1E2 Ph: ++1-905-857-1050 ctl@cath-tech.com
More informationLONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES
LONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES IEEE PES Transmission and Distribution Conference_ Chicago April 2008 Dean Sharafi Introduction Electro-magnetic
More informationapogeeinstruments.com Introducing the PV-100 PV Monitoring Package
apogeeinstruments.com Introducing the PV-100 PV Monitoring Package PV Monitoring Package Introducing the new PV monitoring package (PV-100) designed to work with an SMA cluster controller and offered at
More informationRing Pair Corrosion Monitor : RPCM
Ring Pair Corrosion Monitor : RPCM RPCM is an in-line, piggable, monitor for pipelines, flow lines and process pipework giving true corrosion rate measurement in all service conditions due to full inner
More informationUltramonit sensorbelt; a system for wall thickness monitoring. Håvard Sletvold Axess Orkla Inspection AS, Orkanger, Norway
Ultramonit sensorbelt; a system for wall thickness monitoring Håvard Sletvold Axess Orkla Inspection AS, Orkanger, Norway Email: hsl@axess.no Permanent monitoring - Agenda Technology background Overview
More informationEMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)
EMAT Application on Incoloy furnace Tubing By Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD) Outlines 1. Introduction EMAT 2. EMAT- Ultrasound waves 3. EMAT-Surface waves 4. EMAT-Guided
More informationSurface Potential Surveys Training Manual DA Meter Version
Surface Potential Surveys Training Manual DA Meter Version M. C. Miller Co., Inc. 11640 U.S. Highway 1, Sebastian, FL 32958 U.S.A. Telephone: 772 794 9448; Website: www.mcmiller.com CONTENTS Page Introduction..
More informationDCVG Training Manual G1 Version
DC-Voltage Gradient (DCVG) Surveys Using MCM s Integrated Pipeline Survey Test Equipment and Database Management Package DCVG Training Manual G1 Version M. C. Miller Co., Inc. 11640 U.S. Highway 1, Sebastian,
More informationBulk Current Injection Probe Test Procedure
Bulk Current Injection Probe Test Procedure 1 TABLE OF CONTENTS INTRODUCTION 3 GENERAL INFORMATION 4 TEST METHODS 6 SAFETY 8 FIGURES 9 FORMULAS 12 MAINTENANCE 13 WARRANTY 14 2 INTRODUCTION CURRENT PROBE
More informationPractical Design Considerations for Dense, High-Speed, Differential Stripline PCB Routing Related to Bends, Meanders and Jog-outs
Practical Design Considerations for Dense, High-Speed, Differential Stripline PCB Routing Related to Bends, Meanders and Jog-outs AUTHORS Michael J. Degerstrom, Mayo Clinic degerstrom.michael@mayo.edu
More informationApplication of SLOFEC and Laser Technology for Testing of Buried Pipes
19 th World Conference on Non-Destructive Testing 2016 Application of SLOFEC and Laser Technology for Testing of Buried Pipes Gerhard SCHEER 1 1 TMT - Test Maschinen Technik GmbH, Schwarmstedt, Germany
More informationUsing Critical Zone Inspection and Response Monitoring To Prove Riser Condition. M Cerkovnik -2H Offshore
Using Critical Zone Inspection and Response Monitoring To Prove Riser Condition M Cerkovnik -2H Offshore Agenda 1. Introduction 2. High level methodology 3. Verifying condition 4. Defining requirements
More informationSunPower Installation Manual
SunPower SF System Planning and Assembly SunPower SUNPOWER CORPORATION WWW.SUNPOWERCORP.COM Pub #101001-SP2 October 2010 - Rev. 8 2010 by SunPower, Corp All rights reserved. Part I. Scope, components,
More informationOutdoor Installation 2: Lightning Protection and Grounding
Outdoor Installation 2: Lightning Protection and Grounding Training materials for wireless trainers This one hour talk covers lightning protection, grounding techniques and problems, and electrolytic incompatibility.
More informationUNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering
UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering EXPERIMENT 2 BASIC CIRCUIT ELEMENTS OBJECTIVES The purpose of this experiment is to familiarize the student with
More informationModelling III ABSTRACT
Modelling III Hybrid FE-VIM Model of Eddy Current Inspection of Steam Generator Tubes in the Vicinity of Tube Support Plates S. Paillard, A. Skarlatos, G. Pichenot, CEA LIST, France G. Cattiaux, T. Sollier,
More informationTRANSACTION RECORD TR
COMMON GROUND ALLIANCE BEST PRACTICES COMMITTEE Proposal Form Revision to Best Practice Name: Ralph Graeser Date: 03/09/2015 Affiliation: PA PUC/NAPSR/GPTC Member. Phone: 717-554-3666 E-Mail: rgraeser@pa.gov
More informationEPG. by Chris C. Kleronomos
April 1994 EFFECTIVE EQUIPMENT GROUNDING ECOS Electronics Corporation by Chris C. Kleronomos The quality of the electrical wiring and grounding in a facility containing sensitive electronic equipment is
More informationAsset Protection Cathodic Protection Soil Resistivity Measurement. Work Instruction No.:
Asset Protection Cathodic Protection Soil Resistivity Measurement Approved by: Manager Pipeline Standards 1 PURPOSE This work instruction describes the processes to be followed when measuring soil resistivity.
More informationSTABILITY. SECURITY. INTEGRITY.
MODEL 150 HELICAL ANCHOR SYSTEM PN #MBHAT STABILITY. SECURITY. INTEGRITY. 150 Helical Anchor System About Foundation Supportworks is a network of the most experienced and knowledgeable foundation repair
More informationInduction coil Magnetometer LEMI-120 User Manual
EUSA UKRAIN Induction coil Magnetometer LEMI-120 User Manual LVIV Disclaimer notice All information in this manual is accurate as of July 2014. However, the Laboratory for Electromagnetic Innovations cannot
More informationNational Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002
National Radio Astronomy Observatory Socorro, NM 87801 EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable T. Baldwin June 05, 2002 Summary Double-armor triple-sheath fiber optic cable will be
More informationThe DFI Institute is organized to serve as a primary means through which members of the Institute may participate in improvement of the planning,
The DFI Institute is organized to serve as a primary means through which members of the Institute may participate in improvement of the planning, design and construction aspects of deep foundations and
More informationEVALUATION OF SINGLE MEMBERS IN HISTORICAL STRUCTURES
Course in Non Destructive Testing of Wood 04 Strength Estimation Pág. 1 EVALUATION OF SINGLE MEMBERS IN HISTORICAL STRUCTURES Ferenc Divos University of West Hungary, Sopron FAKOPP Enterprise RILEM meeting,
More informationPenn State University ESM Ultrasonics R&D Laboratory Joseph L. Rose Research Activities
Penn State University ESM Ultrasonics R&D Laboratory Joseph L. Rose Research Activities Crack Detection in Green Compacts The Center for Innovative Sintered Products Identifying cracked green parts before
More informationStarTrak Pigging Technologies
StarTrak Pigging Technologies 27235 West Highway Blvd. Katy, Texas, 77494 281-599-7557 Introduction Pipeline Pigs are dispatched through pipelines to perform various functions: 1: To clean the inner wall
More informationASME V&V Authors: Marcus Gamino Samuel Abankwa Ricardo Silva Leonardo Chica Paul Yambao
Examining the Dampening Effect of Pipe-Soil Interaction at the Ends of a Subsea Pipeline Free Span Using Coupled Eulerian-Lagrangian Analysis and Computational Design of Experiments Authors: Marcus Gamino
More information