Developments in Ultrasonic Guided Wave Inspection

Size: px
Start display at page:

Download "Developments in Ultrasonic Guided Wave Inspection"

Transcription

1 Developments in Ultrasonic Guided Wave Inspection Wireless Structural Health Monitoring Technology for Heat Exchanger Shells using Magnetostrictive Sensor Technology N. Muthu, EPRI, USA; G. Light, Southwest Research Institute, USA INTRODUCTION There are a large number of heat exchanger units throughout nuclear power plants. The heat exchanger shell is a pressure vessel that surrounds and encloses a heat exchanger unit. The shell is susceptible to corrosion and wear, especially around the nozzle area where steam is often deflected inside the shell toward the shell wall. The nominal dimensions of these shells are 30 to 50 feet long with diameters ranging from 30 to 60 inches and wall thickness of ranging from approximately 19mm (0.75 inch) up to 32mm (1.25inches). The heat exchanger shell is covered with insulation. At the present time, periodic inspection of the shell wall is required to monitor wall loss and establish trending data. This process usually consists of collecting ultrasonic wall thickness measurements in specific grid locations. This is a laborious process that often provides data that is difficult to correlate and to use because data is not always collected from the grid locations. A method that provides consistent monitoring of the entire shell, requires minimal labor, and provides data that is easy to correlate to damage is needed. To meet this need, EPRI NDE Center funded SwRI to evaluate a long range, magnetostrictive guided wave technology for monitoring the shell wall. The magnetostricitve sensors (MsS) are low profile (approximately 0.25mm (0.01 ) in height), produce a guided wave that can propagate in the steel up to distances of 10m or more, and are relatively inexpensive. This means that the MsS can be installed with the insulation placed over the sensors and left permanently installed. The effort consisted of initial evaluation, fabrication of the monitoring system, and testing of the system in the laboratory. The system functions are conceptually illustrated in Figure 1 consisting of segmented exciter magnetostrictive pulse-echo sensors bonded to the heat exchanger shell, 20 channel multiplexer, MsSR3030 instrument, a remote station, a wireless dualband n communication system, and a desk top computer. The magnetostrictive (MsS) sensors are thin ferromagnetic strips bonded to the surface of the heat exchanger shell that are excited to generate ultrasonic guided waves in the shell wall using a thin excitation coil. The MsS sensors generate ultrasonic guided wave beam in the shell wall as illustrated in Figure 2.

2 Figure 1 - Illustration of MsS Monitoring System for the heat exchanger shell + direction Directionally controlled plate monitoring beams, one in the + direction and then one in the - direction - direction ~20-30ft 10-20ft Figure 2 - Illustration of the plate monitoring beams generated by the MsS sensors on a heat exchanger shell. The defect detection sensitivity is governed generally by the ratio of the defect cross section to the beam cross section at the location of the defect The purpose of this paper is to describe the system components and discuss testing that characterized the performance of the system components and the overall system.

3 DISCUSSION OF SYSTEM COMPONENTS AND RESULTS OBTAINED FROM CHARACTERIZING THE COMPONENTS Even though various versions of each of the components had been fabricated before or were off the shelf, the characteristics of each component had to evaluated and optimized for use in the Heat Exchanger Shell Monitoring System. The key components of the system including the probes, the multiplexer, the MsSR3030, the wireless system, and the data acquisition and analysis system. The following sections discuss the experimental work conducted to evaluate, characterize, and optimize the components for the MsS Heat Exchanger Monitoring System. MsS Probe Coverage and Defect Detection Sensitivity The MsS probes consists of the FeCo magnetostrictive material bonded to the outside shell wall and the excitation coil. To understand the coverage of the sensors, it was important to characterize the beam patterns produced by the sensors. To provide optimized frequency and directionality control, the coil design had to be optimized. Finally, the epoxy bonding material had to operate at temperatures as high as 300oF. The FeCo material used is a 0.127mm (0.005 inch) thick strip that is 50.8mm (2 inches) wide. The strip is bonded to the shell using DP125 epoxy. The sensors size and frequency was evaluated to determine coverage and guided wave mode generation. The test plate (illustrated in Figure 3) was used to evaluate the beam radiation pattern and coverage as a function of frequency and sensor length. The MsS was used to generate the guided wave and a small MsS sensor was moved along the FeCo material at each of the three locations shown to receive the transmitted wave. One of the radiation patterns obtained is shown in Figure 4. Figure 3 - Illustration of the test plate used to evaluate the sensor radiation pattern and coverage as a function of frequency and sensor length Figure 4 - Radiation pattern obtained from a 64KHz MsS sensor The theoretical expression for the radiation pattern at the -6dB from maximum is given by θ 1/2 = 0.44 sin -1 (λ/d)

4 where θ 1/2 is the half angle, λ is the wavelength, and D length of the probe. The experimental data obtained are shown in the Table 1 and validated this expression, so that beam coverage could be predicted. θ 1/2, full beam Theory ( Degrees) θ -6dB Theory ( Degrees) θ -6dB Measured ( Degrees) Wavelength (λ Probe length in inches) (D in inches) 32 khz khz khz khz * 128 khz * Table 1 Testing to determine defect detection sensitivity and signal attenuation was conducted using frequencies of 32, 64, and 128KHz. Initially, test defects that were round bottom holes (6.35mm (1/4 ) in diameter and 6.35mm (1/4 )deep) were used to test the defect detection sensitivity. Each defect represented approximately 0.1% of the beam cross section at the distance from the probe. To increase the defect cross section in the beam, multiple holes were drilled in the plate at a 6.35mm (1/4 ) edge to edge spacing. Since the system is to be used in a monitoring mode, initial waveforms at each frequency were obtained prior to introduction of defects and subsequent waveforms were taken with each frequency after each defect was introduced into the plate. The difference waveform was obtained for each case and the amplitude of the difference waveform was plotted as a function of the cross section of the defect. At 64KHz, the amplitude and signal to noise data obtained as the defect cross sectional area was increased is shown in Figure 5. If the detection S/N threshold of 2 is used, then defects on the order of 0.4% beam cross section can be detected. Figure 5 - Plot of Defect Signal Amplitude and Defect Signal to Noise as a Function of Defect Cross Section Relative to the Beam Cross Section To validate that the sensors could work at 300 o F and the sensor coverage, sensors were bonded on a test plate that could be heated and insulated. This plate is shown in Figure 6. The sensor layout plan is shown in Figure 7. The nozzle region was approximately 3.5m (11 1/2 ) from the sensors placed along the length of the plate. Because there is a dead zone directly in front of the sensors, a number of sensors were placed parallel to the length of the plate and one sensor was also placed parallel to the length of the plate for propagating a beam behind the nozzle cut out.

5 Figure 6 - Photograph of test plate used to simulate heat exchanger surface in lab (top) with sensors bonded in place, with plate heaters (middle) and finally insulated (bottom) Figure 7 - Sensor layout plan on test plate Discussion of Data Collected Examples of differential waveform data collected from several sensors at various locations (shown in Figure 8) with defects (increasing in cross section) in the locations shown in Figure 7 are provided in Figures 9 through 11. These differential waveforms show that defects as small as 0.4% of the total beam cross section can be detected. The data in Figure 9 is for a defect that was placed (and increased in size in subsequent steps of 0.2% of the cross section) behind the nozzle. The defect is located approximately 1270mm (50inches) from the sensor. The wave propagated by this sensor would generally go around the shell and not see the large signal at 1900mm (75 inches) that is seen in this simulated lab test.

6 Figure 8 - Illustration showing locations of sensors. Figure 9 - Plot of Difference of MsS data collected from sensor 1 as the defect was increased from 0 defect to a 1.6% defect. The defect was approximately 50 inches from the sensor. The data shown in Figure 10 is from sensor 4 looking toward the nozzle. The defect detected is approximately 2280mm (90 inches) from the sensor and it is clear that as the defect reach even 0.2% of the cross section of the beam it is detectable. This defect is 4.5mm (0.18inch) in diameter by 6.35mm (1/4 inch) in diameter. Because of the radiation pattern of the sensors, this defect is also seen by sensor 5 as shown in Figure 11. For this sensor, the defect detection sensitivity was approximately 0.4% of the beam cross section.

7 Figure 10 - Differential data from sensor 4 as the defect grow in cross section from 0 to 1.8% in steps of 0.2% cross section. The defect is approximately 90 inches from the sensor. Discussion of the Wireless Communication System and the Multiplexer The wireless system used for the system was the dualband n communication system as illustrated in Figure 1 and shown in Figure 12. The multiplexer is shown in Figure 13. However, it is important to note that the wireless function is not necessary. If there is concern at the utility about using the wireless technology, the data can be obtained periodically at the MsS instrument.

8 Figure 11 - Differential data from sensor 5 as the defect grow in cross section from 0 to 1.8% in steps of 0.2% cross section. The defect is approximately 88 inches from the sensor. Figure 12 - Photograph of the dualband n communication system

9 Figure 13 - Photograph of the 20 channel multiplexer Conclusions A multichannel MsS heat exchanger monitoring system has been completed. The system is ready to be tested in a field trial at a utility. The other conclusions were as follows (1) a consistent on-line monitoring using multiplexed sensors was developed, (2) the potential for simultaneous monitoring of many heat exchangers through the use of multiple multiplexers has been illustrated, (3) there is no need to remove insulation to collect periodic data, (4) should allow a utility to better achieve ALARA goals, (5) allows inspection repeatability, (6) should provide a means to avoid unplanned shutdowns, (7) should lead to cost savings in repair and replacement activities, and (8) monitoring may be performed at each heat exchanger location or remotely using acceptable wireless technology.

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection Ik-Keun PARK 1,a, Yong-Kwon KIM 2,b, Sae-Jun PARK

More information

DEFECT SIZING IN PIPE USING AN ULTRASONIC GUIDED WAVE FOCUSING TECHNIQUE

DEFECT SIZING IN PIPE USING AN ULTRASONIC GUIDED WAVE FOCUSING TECHNIQUE DEFECT SIZING IN PIPE USING AN ULTRASONIC GUIDED WAVE FOCUSING TECHNIQUE Jing Mu 1, Li Zhang 1, Joseph L. Rose 1 and Jack Spanner 1 Department of Engineering Science and Mechanics, The Pennsylvania State

More information

Long-Range Inspection of Suspender Ropes in Suspension Bridges Using the Magnetstrictive Sensor Technology Dyab A. Khazem, Hegeon Kwun, Sang-Young

Long-Range Inspection of Suspender Ropes in Suspension Bridges Using the Magnetstrictive Sensor Technology Dyab A. Khazem, Hegeon Kwun, Sang-Young Long-Range Inspection of Suspender Ropes in Suspension Bridges Using the Magnetstrictive Sensor Technology Dyab A. Khazem, Hegeon Kwun, Sang-Young Kim, and Chris Dynes ABSTRACT The applicability of a long-range

More information

High-Resolution Corrosion Monitoring for Reliable Assessment of Infrastructure

High-Resolution Corrosion Monitoring for Reliable Assessment of Infrastructure 19 th World Conference on Non-Destructive Testing 2016 High-Resolution Corrosion Monitoring for Reliable Assessment of Infrastructure André Lamarre 1 1 Olympus Scientific Solutions Americas, Quebec City,

More information

AN EMAT ARRAY FOR THE RAPID INSPECTION OF LARGE STRUCTURES USING GUIDED WAVES. Paul Wilcox 1, Mike Lowe 2

AN EMAT ARRAY FOR THE RAPID INSPECTION OF LARGE STRUCTURES USING GUIDED WAVES. Paul Wilcox 1, Mike Lowe 2 AN EMAT ARRAY FOR THE RAPID INSPECTION OF LARGE STRUCTURES USING GUIDED WAVES Paul Wilcox 1, Mike Lowe 2 least as important as the issue of modal selectivity. For example, a defect free rectangular plate

More information

MONITORING TECHNOLOGY FOR EARLY DETECTION OF INTERNAL CORROSION FOR PIPELINE INTEGRITY

MONITORING TECHNOLOGY FOR EARLY DETECTION OF INTERNAL CORROSION FOR PIPELINE INTEGRITY MONITORING TECHNOLOGY FOR EARLY DETECTION OF INTERNAL CORROSION FOR PIPELINE INTEGRITY Final Report March 25, 2002 September 24, 2003 Prepared by Glenn M. Light, Sang Y. Kim, Robert L. Spinks, and Hegeon

More information

Electromagnetic Eddy Current Sensors for Evaluation of Sea-Cure and 2205 Duplex Condenser Tubing

Electromagnetic Eddy Current Sensors for Evaluation of Sea-Cure and 2205 Duplex Condenser Tubing 6th European Workshop on Structural Health Monitoring - We.3.B.2 More info about this article: http://www.ndt.net/?id=14151 Electromagnetic Eddy Current Sensors for Evaluation of Sea-Cure and 2205 Duplex

More information

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho

Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants. Younho Cho Application of Ultrasonic Guided Waves for Characterization of Defects in Pipeline of Nuclear Power Plants Younho Cho School of Mechanical Engineering, Pusan National University, Korea ABSTRACT State-of-art

More information

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound MultiScan MS 5800 Tube Inspection System Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound 920-107 MultiScan MS 5800 E Tube Inspection with Eddy Current Condensers

More information

CIRCULAR LAMB AND LINEAR SHEAR HORIZONTAL GUIDED WAVE ARRAYS FOR STRUCTURAL HEALTH MONITORING

CIRCULAR LAMB AND LINEAR SHEAR HORIZONTAL GUIDED WAVE ARRAYS FOR STRUCTURAL HEALTH MONITORING CIRCULAR LAMB AND LINEAR SHEAR HORIZONTAL GUIDED WAVE ARRAYS FOR STRUCTURAL HEALTH MONITORING Thomas R. Hay, Jason Van Velsor, Joseph L. Rose The Pennsylvania State University Engineering Science and Mechanics

More information

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound

MultiScan MS Tube Inspection System. Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound MultiScan MS 5800 Tube Inspection System 920-107 Multi-technology System Eddy Current Magnetic Flux Leakage Remote Field IRIS Ultrasound MultiScan MS 5800 E Tube Inspection with Eddy Current Condensers

More information

ADVANCED COMBINATION PROBE FOR TESTING FERRITIC SEA-CURE CONDENSER TUBING

ADVANCED COMBINATION PROBE FOR TESTING FERRITIC SEA-CURE CONDENSER TUBING ADVANCED COMBINATION PROBE FOR TESTING FERRITIC SEA-CURE CONDENSER TUBING Kenji Krzywosz, Electric Power Research Institute (EPRI), Daniel Folsom, Tennessee Valley Authority (TVA), USA ABSTRACT As more

More information

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK The Guided wave testing method (GW) is increasingly being used worldwide to test

More information

TECHNICAL BACKGROUND ON MsS

TECHNICAL BACKGROUND ON MsS TECHNICAL BACKGROUND ON MsS Sensor Principle Guided wave generation Based on the magnetostrictive (or Joule) effect Guided wave detection Based on the inverse-magnetostrictive (or Villari) effect The magnetostrictive

More information

Steam Generator Tubing Inspection

Steam Generator Tubing Inspection 6th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurized Components October 27, Budapest, Hungary For more papers of this publication click: www.ndt.net/search/docs.php3?mainsource=7

More information

Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures

Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures Array Eddy Current for Fatigue Crack Detection of Aircraft Skin Structures Eric Pelletier, Marc Grenier, Ahmad Chahbaz and Tommy Bourgelas Olympus NDT Canada, NDT Technology Development, 505, boul. du

More information

Table 1 The wheel-set security system of China high-speed railway

Table 1 The wheel-set security system of China high-speed railway 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic More Info at Open Access Database www.ndt.net/?id=16352 Dynamic ultrasonic inspection technology

More information

Ultrasonic Guided Wave Applications

Ultrasonic Guided Wave Applications Ultrasonic Guided Wave Applications Joseph L. Rose Penn State University April 29-30, 2013 2013 Center for Acoustics and Vibrations meeting What is a Guided Wave? (Guided wave requires boundary for propagation

More information

Simulation of Ultrasonic Testing of Rail Wheel Face using Phased Array and DDF technique

Simulation of Ultrasonic Testing of Rail Wheel Face using Phased Array and DDF technique Simulation of Ultrasonic Testing of Rail Wheel Face using Phased Array and DDF technique Anand Desai, Ph.D. Abstract This paper presents a method of increasing the near surface resolution of a rail wheel

More information

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING

ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING ACOUSTO-ULTRASONIC EVALUATION OF HYBRID COMPOSITES USING OBLIQUE INCIDENCE WAVES INTRODUCTION Yuyin Ji, Sotirios J. Vahaviolos, Ronnie K. Miller, Physical Acoustics Corporation P.O. Box 3135 Princeton,

More information

Heat Exchanger & Boiler Tube Inspection Techniques

Heat Exchanger & Boiler Tube Inspection Techniques Overview For the in-service inspection of ferromagnetic, non-ferromagnetic and fin-fan tubes, the following advanced techniques offer high defect detection capabilities and accurate defect analysis: Multiple

More information

NDI Techniques Supporting Steel Pipe Products

NDI Techniques Supporting Steel Pipe Products JFE TECHNICAL REPORT No. 7 (Jan. 26) IIZUKA Yukinori *1 NAGAMUNE Akio *2 MASAMURA Katsumi *3 Abstract: This paper describes JFE original ultrasonic testing (UT) technologies in Non-destructive inspection

More information

Ultrasonic Level Detection Technology. ultra-wave

Ultrasonic Level Detection Technology. ultra-wave Ultrasonic Level Detection Technology ultra-wave 1 Definitions Sound - The propagation of pressure waves through air or other media Medium - A material through which sound can travel Vacuum - The absence

More information

New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines

New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines A. Barbian 1, M. Beller 1, F. Niese 2, N. Thielager 1, H. Willems 1 1 NDT Systems & Services

More information

High-temperature Ultrasonic Thickness Gauges for On-line Monitoring of Pipe Thinning for FAC Proof Test Facility

High-temperature Ultrasonic Thickness Gauges for On-line Monitoring of Pipe Thinning for FAC Proof Test Facility High-temperature Ultrasonic Thickness Gauges for On-line Monitoring of Pipe Thinning for FAC Proof Test Facility Yong-Moo Cheong 1, Se-Beom Oh 1, Kyung-Mo Kim 1, and Dong-Jin Kim 1 1 Nuclear Materials

More information

OVERVIEW AND EXPERIMENTAL EVALUATION OF

OVERVIEW AND EXPERIMENTAL EVALUATION OF OVERVIE AND EXPERIMENTAL EVALUATION OF MAGNETOSTRICTIVE TRANSDUCERS FOR GUIDED AVE INSPECTION Francesco Bertoncini*, Giuseppe Giunta**, Marco Raugi*, Florin Turcu* *Department of Energy and Systems Engineering

More information

Guided Wave Testing - Maximizing Buried Pipe Corrosion Knowledge from each Excavation

Guided Wave Testing - Maximizing Buried Pipe Corrosion Knowledge from each Excavation Proceedings of the ASME 2012 Pressure Vessels & Piping Conference PVP2012 July 15-19, 2012, Toronto, Ontario, CANADA PVP2012-78561 Guided Wave Testing - Maximizing Buried Pipe Corrosion Knowledge from

More information

An instrument for detecting corrosion in anchorage zones of bridge cables using guided waves

An instrument for detecting corrosion in anchorage zones of bridge cables using guided waves 18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa An instrument for detecting corrosion in anchorage zones of bridge cables using guided waves Jiang XU, Xinjun WU,

More information

Long Range Ultrasonic Testing - Case Studies

Long Range Ultrasonic Testing - Case Studies More info about this article: http://www.ndt.net/?id=21145 Prawin Kumar Sharan 1, Sheethal S 1, Sri Krishna Chaitanya 1, Hari Kishore Maddi 1 1 Sievert India Pvt. Ltd. (A Bureau Veritas Company), 16 &

More information

A Novel Self Calibrating Pulsed Eddy Current Probe for Defect Detection in Pipework

A Novel Self Calibrating Pulsed Eddy Current Probe for Defect Detection in Pipework Malaysia NDT Conference November 2015 A Novel Self Calibrating Pulsed Eddy Current Probe for Defect Detection in Pipework S.Majidnia,J.Rudlin, R.Nilavalan PEC Applications Corrosion under Insulation for

More information

Non-Destructive Method Based on Rayleigh-Like Waves to Detect Corrosion Thinning on Non- Accessible Areas

Non-Destructive Method Based on Rayleigh-Like Waves to Detect Corrosion Thinning on Non- Accessible Areas 19 th World Conference on Non-Destructive Testing 2016 Non-Destructive Method Based on Rayleigh-Like Waves to Detect Corrosion Thinning on Non- Accessible Areas Laura TAUPIN 1, Frédéric JENSON 1*, Sylvain

More information

Feasibility of Detection of Leaking Fuel Rods Using Side Coupled Guided Waves

Feasibility of Detection of Leaking Fuel Rods Using Side Coupled Guided Waves Presented at the Sixth Japan-US NDT Symposium Emerging NDE Capabilities for a Safer World, July 8-12, 2018, Hawaii Convention Center, Oahu, Hawaii, USA Feasibility of Detection of Leaking Fuel Rods Using

More information

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING

ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING ULTRASONIC GUIDED WAVE ANNULAR ARRAY TRANSDUCERS FOR STRUCTURAL HEALTH MONITORING H. Gao, M. J. Guers, J.L. Rose, G. (Xiaoliang) Zhao 2, and C. Kwan 2 Department of Engineering Science and Mechanics, The

More information

DEVELOPMENT OF ULTRASONIC WAVE NONDESTRUCTIVE INSPECTION ROBOT WITHOUT COUPLING MEDIUM USING EMAT

DEVELOPMENT OF ULTRASONIC WAVE NONDESTRUCTIVE INSPECTION ROBOT WITHOUT COUPLING MEDIUM USING EMAT DEVELOPMET OF ULTRAOIC WAVE ODETRUCTIVE IPECTIO ROBOT WITHOUT COUPLIG MEDIUM UIG EMAT R. Murayama,. Makiyama, Y. Aratani and Y. Taniguchi Fukuoka Institute of technology, Japan Abstract: The ultrasonic

More information

Multiple Frequency Eddy Current Technique

Multiple Frequency Eddy Current Technique Multiple Frequency Eddy Current Technique Signal Amplitude Signal Amplitude Multiple Frequency Eddy Current Technique Multiple Frequency Eddy Current technique is one of the non destruction inspection

More information

Corrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing

Corrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing 4th International Symposium on NDT in Aerospace 2012 - Poster 4 Corrosion Steel Inspection under Steel Plate Using Pulsed Eddy Current Testing D.M. SUH *, K.S. JANG **, J.E. JANG **, D.H. LEE ** * Raynar

More information

Application of Guided Wave Technology to Tube Inspection

Application of Guided Wave Technology to Tube Inspection ECNDT 2006 - Th.3.1.5 Application of Guided Wave Technology to Tube Inspection T. VOGT, D. ALLEYNE, B. PAVLAKOVIC, Guided Ultrasonics Limited, Nottingham, United Kingdom 1. Introduction Abstract. The inspection

More information

Sensor Systems and NDE Technology Section January 2017

Sensor Systems and NDE Technology Section January 2017 Sensor Systems and NDE Technology Section January 2017 Sensor System and NDE Technology Section Staff and Project Breakdown Total staff 17 16 hold technical degrees (EE, ME, and physics) 5 with Ph.D. Projects

More information

DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER

DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER DEEP PENETRATING EDDY CURRENT for DETECTING VOIDS in COPPER Tadeusz Stepinski (Uppsala University, Signals and System, P.O.Box 528, SE-75 2 Uppsala, Sweden, ts@signal.uu.se) Abstract Assessment of copper

More information

Further Developments in Ultrasonic Phased Array Inspection of Aging Aircraft

Further Developments in Ultrasonic Phased Array Inspection of Aging Aircraft Further Developments in Ultrasonic Phased Array Inspection of Aging Aircraft Irene G Pettigrew 1, David I A Lines 2, Jesse A Skramstad 3, Robert A Smith 4 and Katherine J Kirk 1 1 Microscale Sensors, Institute

More information

Developments in Electromagnetic Inspection Methods I

Developments in Electromagnetic Inspection Methods I 6th International Conference on NDE in Relation to Structural Integrity for Nuclear and Pressurized Components October 2007, Budapest, Hungary For more papers of this publication click: www.ndt.net/search/docs.php3?mainsource=70

More information

DACON INSPECTION SERVICES. Phased Array Ultrasonic Testing

DACON INSPECTION SERVICES. Phased Array Ultrasonic Testing Phased Array Ultrasonic Testing Who we are Conventional and Advanced NDT and Inspection Services Oil and Gas, Refinery, Petrochemical, Heavy Industry, Mining Over 400 personnel including more than 300

More information

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE

ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE ASSESSMENT OF WALL-THINNING IN CARBON STEEL PIPE BY USING LASER-GENERATED GUIDED WAVE DOYOUN KIM, YOUNHO CHO * and JOONHYUN LEE Graduate School of Mechanical Engineering, Pusan National University Jangjeon-dong,

More information

BINDT Telford. Guided Wave Testing and Monitoring Over Long and Short Ranges

BINDT Telford. Guided Wave Testing and Monitoring Over Long and Short Ranges BINDT Telford Guided Wave Testing and Monitoring Over Long and Short Ranges David Alleyne, Tomasz Pialucha and Brian Pavlakovic 6 September 2017 Outline Background Guided Wave Testing (GWT) Concepts Wave

More information

INTERNAL CONCRETE INSPECTION AND EVALUATION METHODS FOR STEEL PLATE-BONDED SLABS BY USING ELASTIC WAVES VIA ANCHOR BOLTS

INTERNAL CONCRETE INSPECTION AND EVALUATION METHODS FOR STEEL PLATE-BONDED SLABS BY USING ELASTIC WAVES VIA ANCHOR BOLTS More info about this article: h Czech Society for Nondestructive Testing 32 nd European Conference on Acoustic Emission Testing Prague, Czech Republic, September 7-9, 216 INTERNAL CONCRETE INSPECTION AND

More information

Detection and Assessment of Wood Decay in Glulam Beams Using a Decay Rate Approach: A Review

Detection and Assessment of Wood Decay in Glulam Beams Using a Decay Rate Approach: A Review In: Proceedings of the 18th International Nondestructive Testing and Evaluation of Wood Symposium held on Sept. 24-27, 2013, in Madison, WI. Detection and Assessment of Wood Decay in Glulam Beams Using

More information

Structural Integrity Monitoring using Guided Ultrasonic Waves

Structural Integrity Monitoring using Guided Ultrasonic Waves Structural Integrity Monitoring using Guided Ultrasonic Waves Paul Fromme Department of Mechanical Engineering University College London NPL - May 2010 Structural Integrity Monitoring using Guided Ultrasonic

More information

IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES USING REMOTE FIELD EDDY CURRENT

IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES USING REMOTE FIELD EDDY CURRENT 12 th A-PCNDT 2006 Asia-Pacific Conference on NDT, 5 th 10 th Nov 2006, Auckland, New Zealand IMPROVEMENT OF DETECTION OF SMALL DEFECTS LOCATED NEAR OR FAR FROM WELDS OF MAGNETIC STEAM GENERATOR TUBES

More information

A Breakthrough in Sputtering Target Inspections: Ultra-High Speed Phased Array Scanning with Volume Focusing

A Breakthrough in Sputtering Target Inspections: Ultra-High Speed Phased Array Scanning with Volume Focusing 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China A Breakthrough in Sputtering Target Inspections: Ultra-High Speed Phased Array Scanning with Volume Focusing Dominique Braconnier,

More information

Review of Guided Wave Testing Using Magnetostrictive Transducers INTRODUCTION

Review of Guided Wave Testing Using Magnetostrictive Transducers INTRODUCTION Page 1 of 9 More info about this article: http://www.ndt.net/?id=22930 Review of Guided Wave Testing Using Magnetostrictive Transducers Abstract Sergey Vinogradov 1, Jay Fisher 2 1 Southwest Research Institute,

More information

Ultrasonic Guided Waves for NDT and SHM

Ultrasonic Guided Waves for NDT and SHM Ultrasonic Guided Waves for NDT and SHM Joseph L. Rose Paul Morrow Professor Engineering Science & Mechanics Department Penn State University Chief Scientist FBS,Inc. CAV Presentation May 4, 2009 The difference

More information

ANNULAR ARRAY SEARCH UNITS AND THEIR POTENTIAL APPLICATION IN CONVENTIONAL ULTRASONIC TESTING SYSTEMS ABSTRACT

ANNULAR ARRAY SEARCH UNITS AND THEIR POTENTIAL APPLICATION IN CONVENTIONAL ULTRASONIC TESTING SYSTEMS ABSTRACT ANNULAR ARRAY SEARCH UNITS AND THEIR POTENTIAL APPLICATION IN CONVENTIONAL ULTRASONIC TESTING SYSTEMS Jerry T. McElroy and Kenneth F. Briers Quality Assurance Systems and Engineering Division Southwest

More information

30th European Conference on Acoustic Emission Testing & 7th International Conference on Acoustic Emission University of Granada, 12-15 September 2012 www.ndt.net/ewgae-icae2012/ Qualification of the acoustic

More information

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites

Keywords: Ultrasonic Testing (UT), Air-coupled, Contact-free, Bond, Weld, Composites Single-Sided Contact-Free Ultrasonic Testing A New Air-Coupled Inspection Technology for Weld and Bond Testing M. Kiel, R. Steinhausen, A. Bodi 1, and M. Lucas 1 Research Center for Ultrasonics - Forschungszentrum

More information

Rayleigh Wave Interaction and Mode Conversion in a Delamination

Rayleigh Wave Interaction and Mode Conversion in a Delamination Rayleigh Wave Interaction and Mode Conversion in a Delamination Sunil Kishore Chakrapani a, Vinay Dayal, a and Jamie Dunt b a Department of Aerospace Engineering & Center for NDE, Iowa State University,

More information

Fig. 1 Feeder pipes in the pressurized heavy water reactor.

Fig. 1 Feeder pipes in the pressurized heavy water reactor. DETECTION OF AXIAL CRACKS IN A BENT PIPE USING EMAT TORSIONAL GUIDED WAVES Yong-Moo Cheong 1, Sang-Soo Kim 1, Dong-Hoon Lee 1, Hyun-Kyu Jung 1, and Young H. Kim 2 1 Korea Atomic Energy Research Institute,

More information

Developments in Ultrasonic Phased Array Inspection I

Developments in Ultrasonic Phased Array Inspection I Developments in Ultrasonic Phased Array Inspection I A Detailed Study of Inspecting Thick Parts Using Large Aperture Phased Arrays and DDF D. Braconnier, S. Okuda, G. Dao, KJTD co. Ltd, Japan ABSTRACT

More information

PEOPLE PROCESS EQUIPMENT TECHNOLOGY VALUE. Cased-Hole Services Optimize Your Well Production

PEOPLE PROCESS EQUIPMENT TECHNOLOGY VALUE. Cased-Hole Services Optimize Your Well Production PEOPLE PROCESS EQUIPMENT TECHNOLOGY VALUE Cased-Hole Services Optimize Your Well Production Optimize Your Well Production Allied-Horizontal s complete portfolio of reservoir evaluation and completion services

More information

NDT-PRO Services expands service offering

NDT-PRO Services expands service offering NDT-PRO Services expands service offering NDT-PRO Services announced the formal release of two advanced NDT methods, Phased Array (including TOFD) and Eddy Current. What are they and where are the used?

More information

Acoustic emission signal attenuation in the waveguides used in underwater AE testing.

Acoustic emission signal attenuation in the waveguides used in underwater AE testing. 1 Acoustic emission signal attenuation in the waveguides used in underwater AE testing. Zakharov D.A., Ptichkov S.N., Shemyakin V.V. OAO «ОКBM Afrikantov», «Diapac» Ltd. In the paper presented are the

More information

DEVELOPMENT OF ENHANCED GUIDED WAVE SCREENING USING BROADBAND MAGNETOSTRICTIVE TRANSDUCER AND NON-LINEAR SIGNAL PROCESSING

DEVELOPMENT OF ENHANCED GUIDED WAVE SCREENING USING BROADBAND MAGNETOSTRICTIVE TRANSDUCER AND NON-LINEAR SIGNAL PROCESSING The Open Access NDT Database DEVELOPMENT OF ENHANCED GUIDED WAVE SCREENING USING BROADBAND MAGNETOSTRICTIVE TRANSDUCER AND NON-LINEAR SIGNAL PROCESSING Sergey Vinogradov IHI Southwest Technologies, Inc.

More information

CRACK DETECTION AND DEFECT CLASSIFICATION USING THE LLT - TECHNIQUE. Wolfgang Gebhardt and Friedhelm Walte

CRACK DETECTION AND DEFECT CLASSIFICATION USING THE LLT - TECHNIQUE. Wolfgang Gebhardt and Friedhelm Walte CRACK DETECTION AND DEFECT CLASSIFICATION USING THE LLT - TECHNIQUE Wolfgang Gebhardt and Friedhelm Walte Fraunhofer-Institut fur zerstorungsfreie Prufverfahren Universitat, Gebaude 37 D-6600 Saarbrucken,

More information

MIRA Purpose MIRA Tomographer MIRA MIRA Principle MIRA MIRA shear waves MIRA

MIRA Purpose MIRA Tomographer MIRA MIRA Principle MIRA MIRA shear waves MIRA Purpose The MIRA Tomographer is a state-of-the-art instrument for creating a three-dimensional (3-D) representation (tomogram) of internal defects that may be present in a concrete element. MIRA is based

More information

EDDY CURRENT MEASUREMENT OF REMOTE TUBE POSITIONS IN CANDU REACTORS S.T. Craig, T.W. Krause, B.V. Luloff and J.J. Schankula Atomic Energy of Canada

EDDY CURRENT MEASUREMENT OF REMOTE TUBE POSITIONS IN CANDU REACTORS S.T. Craig, T.W. Krause, B.V. Luloff and J.J. Schankula Atomic Energy of Canada EDDY CURRENT MEASUREMENT OF REMOTE TUBE POSITIONS IN CANDU REACTORS S.T. Craig, T.W. Krause, B.V. Luloff and J.J. Schankula Atomic Energy of Canada Limited, Chalk River, Ontario, Canada Abstract: Regular

More information

MULTI-CHANNEL ULTRASONIC FLAW DETECTOR ОКО-22М-UT THE BEST INDUSTRIAL OEM SOLUTION FOR IN-LINE AND IN-SERVICE SYSTEMS

MULTI-CHANNEL ULTRASONIC FLAW DETECTOR ОКО-22М-UT THE BEST INDUSTRIAL OEM SOLUTION FOR IN-LINE AND IN-SERVICE SYSTEMS MULTI-CHANNEL ULTRASONIC FLAW DETECTOR ОКО-22М-UT THE BEST INDUSTRIAL OEM SOLUTION FOR IN-LINE AND IN-SERVICE SYSTEMS www.ndt.com.ua PURPOSE OKO-22M-UT PRO WIRELESS INTERFACE WI-FI The ОКО-22М-UT ultrasonic

More information

Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT)

Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT) Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT) Author: Ankit Vajpayee Russell NDE Systems Inc. 4909 75Ave Edmonton, Alberta, Canada T6B 2S3 Phone 780-468-6800

More information

Sonic Distance Sensors

Sonic Distance Sensors Sonic Distance Sensors Introduction - Sound is transmitted through the propagation of pressure in the air. - The speed of sound in the air is normally 331m/sec at 0 o C. - Two of the important characteristics

More information

Development of the air-coupled ultrasonic vertical reflection method

Development of the air-coupled ultrasonic vertical reflection method 15 th Asia Pacific Conference for Non-Destructive Testing (APCNDT217), Singapore. Development of the air-coupled ultrasonic vertical reflection method M. Endo, M. Ishikawa 1, H. Nishino 1 and S.Sugimoto

More information

COMPUTER MODELING OF EDDY CURRENT TRANSMIT-RECEIVE PROBES FOR. S.P. Sullivan, V.S. Cecco, L.S. Obrutsky, D. Humphrey, S.P. Smith and K.A.

COMPUTER MODELING OF EDDY CURRENT TRANSMIT-RECEIVE PROBES FOR. S.P. Sullivan, V.S. Cecco, L.S. Obrutsky, D. Humphrey, S.P. Smith and K.A. COMPUTER MODELING OF EDDY CURRENT TRANSMIT-RECEIVE PROBES FOR TUBE INSPECTION INTRODUCTION S.P. Sullivan, V.S. Cecco, L.S. Obrutsky, D. Humphrey, S.P. Smith and K.A. Emde Nondestructive Testing Development

More information

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual

SL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual USL300 SNOW DEPTH SENSOR Revision 1.1.2 User Manual 1 Table of Contents 1. Introduction... 3 2. Operation... 3 2.1. Electrostatic Transducer... 4 2.2. SL300 Analog Board... 4 2.3. SL300 Digital Circuit

More information

DETECTION OF CORROSION IN BOTTOM PLATES OF GAS AND OIL TANKS USING GUIDED ULTRASONIC WAVES AND ELECTROMAGNETIC ULTRASONIC (EMAT) TRANSDUCERS

DETECTION OF CORROSION IN BOTTOM PLATES OF GAS AND OIL TANKS USING GUIDED ULTRASONIC WAVES AND ELECTROMAGNETIC ULTRASONIC (EMAT) TRANSDUCERS DETECTION OF CORROSION IN BOTTOM PLATES OF GAS AND OIL TANKS USING GUIDED ULTRASONIC WAVES AND ELECTROMAGNETIC ULTRASONIC (EMAT) TRANSDUCERS A Presentation prepared for the Jahrestagung der Deutsche Gesellschaft

More information

Hydrate plug localization and characterization using guided waves

Hydrate plug localization and characterization using guided waves 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Hydrate plug localization and characterization using guided waves More Info at Open Access Database

More information

Air Coupled Ultrasonic Inspection of Steel Rubber Interface

Air Coupled Ultrasonic Inspection of Steel Rubber Interface Air Coupled Ultrasonic Inspection of Steel Rubber Interface More Info at Open Access Database www.ndt.net/?id=15204 Bikash Ghose 1, a, Krishnan Balasubramaniam 2, b 1 High Energy Materials Research Laboratory,

More information

Multi-Mode and Multi-Frequency Differential Lamb Wave Imaging with in situ Sparse Transducer Arrays

Multi-Mode and Multi-Frequency Differential Lamb Wave Imaging with in situ Sparse Transducer Arrays ECNDT 26 - Tu.1.3.3 Multi-Mode and Multi-Frequency Differential Lamb Wave Imaging with in situ Sparse Transducer Arrays Jennifer E. MICHAELS and Thomas E. MICHAELS, School of Electrical and Computer Engineering,

More information

High-Precision Internal Diameter Measurements Using Eddy Current Arrays

High-Precision Internal Diameter Measurements Using Eddy Current Arrays 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China High-Precision Internal Diameter Measurements Using Eddy Current Arrays Benoit LEPAGE 1, Dave KATZ 2,Simon LABBE 1, 1 Olympus

More information

Guided Wave Travel Time Tomography for Bends

Guided Wave Travel Time Tomography for Bends 18 th World Conference on Non destructive Testing, 16-20 April 2012, Durban, South Africa Guided Wave Travel Time Tomography for Bends Arno VOLKER 1 and Tim van ZON 1 1 TNO, Stieltjes weg 1, 2600 AD, Delft,

More information

EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE

EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE EVOLUTION OF THE CRYOGENIC EDDY CURRENT MICROPROBE J.L. Fisher, S.N. Rowland, J.S. Stolte, and Keith S. Pickens Southwest Research Institute 6220 Culebra Road San Antonio, TX 78228-0510 INTRODUCTION In

More information

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection ECNDT - Poster 39 Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection Yago GÓMEZ-ULLATE, Instituto de Acústica CSIC, Madrid, Spain Francisco MONTERO DE ESPINOSA, Instituto de Acústica

More information

Acoustic Emission Linear Location Cluster Analysis on Seam Welded Hot Reheat Piping

Acoustic Emission Linear Location Cluster Analysis on Seam Welded Hot Reheat Piping Acoustic Emission Linear Location Cluster Analysis on Seam Welded Hot Reheat Piping The EPRI Guidelines for acoustic emission (AE) inspection of seamed hot reheat piping were published in November 1995.

More information

In service application of EMAT in Boiler Water Wall Tubes and High Temperature Components

In service application of EMAT in Boiler Water Wall Tubes and High Temperature Components More Info at Open Access Database www.ndt.net/?id=18662 In service application of EMAT in Boiler Water Wall Tubes and High Temperature Components R Dhanasekaran 1, Lopez Borja 2, Mukesh Arora 1 1 NDTS

More information

Studying the Sensitivity of Remote-Field Testing Signals when Faced with Pulling Speed Variations

Studying the Sensitivity of Remote-Field Testing Signals when Faced with Pulling Speed Variations More info about this article: http://www.ndt.net/?id=21592 Studying the Sensitivity of Remote-Field Testing Signals when Faced with Pulling Speed Variations Marc-André Guérard 1, Joe Renaud 1, David Aubé

More information

The Application of TOFD Technique on the Large Pressure Vessel

The Application of TOFD Technique on the Large Pressure Vessel 17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China The Application of TOFD Technique on the Large Pressure Vessel Yubao Guangdong Special Equipment Inspection Institute Floor

More information

Instantaneous Baseline Damage Detection using a Low Power Guided Waves System

Instantaneous Baseline Damage Detection using a Low Power Guided Waves System Instantaneous Baseline Damage Detection using a Low Power Guided Waves System can produce significant changes in the measured responses, masking potential signal changes due to structure defects [2]. To

More information

Isolation Scanner. Advanced evaluation of wellbore integrity

Isolation Scanner. Advanced evaluation of wellbore integrity Isolation Scanner Advanced evaluation of wellbore integrity Isolation Scanner* cement evaluation service integrates the conventional pulse-echo technique with flexural wave propagation to fully characterize

More information

Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components

Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components Flexible PCB-Based Eddy Current Array Probes for the Inspection of Turbine Components Andre Lamarre - OlympusNDT-Quebec City Canada Benoit Lepage - OlympusNDT-Quebec City-Canada Tommy Bourgelas - OlympusNDT-Quebec

More information

2010 ULTRASONIC BENCHMARKS

2010 ULTRASONIC BENCHMARKS World Federation of N D 2010 ULTRASONIC BENCHMARKS E Centers Problems for 2010 This year for the ultrasonic benchmark we have some extensive results of tests performed on a planar block containing surface

More information

Implementation of electromagnetic acoustic resonance in pipe inspection

Implementation of electromagnetic acoustic resonance in pipe inspection E-Journal of Advanced Maintenance Vol.5-1(2013) 25-33 Implementation of electromagnetic acoustic resonance in pipe inspection Ryoichi URAYAMA 1 Toshiyuki TAKAGI 1,*, Tetsuya UCHIMOTO 1, Shigeru KANEMOTO

More information

PRIMARY LOOP ACOUSTIC EMISSION PROCEDURE: AN UPGRADED METHOD AND ITS CONSEQUENCES ON THE IN-SERVICE-INSPECTION

PRIMARY LOOP ACOUSTIC EMISSION PROCEDURE: AN UPGRADED METHOD AND ITS CONSEQUENCES ON THE IN-SERVICE-INSPECTION PRIMARY LOOP ACOUSTIC EMISSION PROCEDURE: AN UPGRADED METHOD AND ITS CONSEQUENCES ON THE IN-SERVICE-INSPECTION Laurent Truchetti, Yann Forestier, Marc Beaumont EDF CEIDRE, EDF Nuclear Engineering Division;

More information

Penn State University ESM Ultrasonics R&D Laboratory Joseph L. Rose Research Activities

Penn State University ESM Ultrasonics R&D Laboratory Joseph L. Rose Research Activities Penn State University ESM Ultrasonics R&D Laboratory Joseph L. Rose Research Activities Crack Detection in Green Compacts The Center for Innovative Sintered Products Identifying cracked green parts before

More information

Simulation Model for SG Eddy Current SG Inspection

Simulation Model for SG Eddy Current SG Inspection Simulation Model for SG Eddy Current SG Inspection Saptarshi Mukherji, Anton Efremov, Pavel Roy, Portia Banerjee, Anders Rosell, L.Udpa Michigan State University & Rick Williams, Nathan Driessen, James

More information

Properties of Interdigital Transducers for Lamb-Wave Based SHM Systems

Properties of Interdigital Transducers for Lamb-Wave Based SHM Systems Properties of Interdigital Transducers for Lamb-Wave Based SHM Systems M. MANKA, M. ROSIEK, A. MARTOWICZ, T. UHL and T. STEPINSKI 2 ABSTRACT Recently, an intensive research activity has been observed concerning

More information

Pipeline long-range inspection and monitoring by an innovative magnetic collar for magnetostrictive guided-wave systems

Pipeline long-range inspection and monitoring by an innovative magnetic collar for magnetostrictive guided-wave systems NDT.net - The e-journal of Nondestructive Testing (December 2008) For more papers of this publication click: www.ndt.net/search/docs.php3?mainsource=25 Pipeline long-range inspection and monitoring by

More information

Development of Under-Sodium Inspection Technique Using Ultrasonic Waveguide Sensor. FR13 4 ~ 7 Mar Paris, France

Development of Under-Sodium Inspection Technique Using Ultrasonic Waveguide Sensor. FR13 4 ~ 7 Mar Paris, France Development of Under-Sodium Inspection Technique Using Ultrasonic Waveguide Sensor FR13 4 ~ 7 Mar. 2013 Paris, France Young-Sang Joo, J.-H. Bae, C-G. Park and J.-B. Kim 1 Outline Under-Sodium Viewing (USV)

More information

DAMAGE DETECTION IN PLATE STRUCTURES USING SPARSE ULTRASONIC TRANSDUCER ARRAYS AND ACOUSTIC WAVEFIELD IMAGING

DAMAGE DETECTION IN PLATE STRUCTURES USING SPARSE ULTRASONIC TRANSDUCER ARRAYS AND ACOUSTIC WAVEFIELD IMAGING DAMAGE DETECTION IN PLATE STRUCTURES USING SPARSE ULTRASONIC TRANSDUCER ARRAYS AND ACOUSTIC WAVEFIELD IMAGING T. E. Michaels 1,,J.E.Michaels 1,B.Mi 1 and M. Ruzzene 1 School of Electrical and Computer

More information

Measurement of phase velocity dispersion curves and group velocities in a plate using leaky Lamb waves

Measurement of phase velocity dispersion curves and group velocities in a plate using leaky Lamb waves Measurement of phase velocity dispersion curves and group velocities in a plate using leaky Lamb waves NDE2002 predict. assure. improve. National Seminar of ISNT Chennai, 5. 7. 12. 2002 www.nde2002.org

More information

EDDY CURRENT INSPECTION MODELLING OF THE ELBOW OF A STEAM GENERATOR TUBE WITH THE FINITE ELEMENT SOFTWARE «FLUX»

EDDY CURRENT INSPECTION MODELLING OF THE ELBOW OF A STEAM GENERATOR TUBE WITH THE FINITE ELEMENT SOFTWARE «FLUX» EDDY CURRENT INSPECTION MODELLING OF THE ELBOW OF A STEAM GENERATOR TUBE WITH THE FINITE ELEMENT SOFTWARE «FLUX» Fabrice FOUCHER*, Bastien LAVIE**, Erwan TOUDIC** * EXTENDE, 86 rue de Paris, 91400 ORSAY,

More information

Corrosion detection under pipe supports using EMAT Medium Range Guided Waves

Corrosion detection under pipe supports using EMAT Medium Range Guided Waves 19 th World Conference on Non-Destructive Testing 2016 Corrosion detection under pipe supports using EMAT Medium Range Guided Waves Victor GARCIA 1, Carlos BOYERO 1, Jesus Antonio JIMENEZ GARRIDO 1 1 Innerspec

More information

High Frequency Ultrasonic Systems with Frequency Ranges of 35 to 200 MHz

High Frequency Ultrasonic Systems with Frequency Ranges of 35 to 200 MHz 19 th World Conference on Non-Destructive Testing 2016 High Frequency Ultrasonic Systems with Frequency Ranges of 35 to 200 MHz Wolfgang HILLGER 1, Lutz BÜHLING 1, Detlef ILSE 1 1 Ingenieurbüro Dr. Hillger,

More information

DEVELOPMENT OF MEASUREMENT SYSTEM USING OPTICAL FIBER AE SENSORS FOR ACTUAL PIPING

DEVELOPMENT OF MEASUREMENT SYSTEM USING OPTICAL FIBER AE SENSORS FOR ACTUAL PIPING DEVELOPMENT OF MEASUREMENT SYSTEM USING OPTICAL FIBER AE SENSORS FOR ACTUAL PIPING SATOSHI NISHINOIRI, PORNTHEP CHIVAVIBUL, HIROYUKI FUKUTOMI and TAKASHI OGATA Materials Science Research Laboratory, Central

More information

D DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction

D DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction Journal of Mechanics Engineering and Automation 6 (2016) 379-383 doi: 10.17265/2159-5275/2016.07.009 D DAVID PUBLISHING Eddy Current Test for Detection of Foreign Material using Rotating Probe Houng Kun

More information