Four Door Access Controller MCP-040 V2.0
|
|
- Morgan Payne
- 5 years ago
- Views:
Transcription
1 Four Door Access Controller MCP-040 V2.0 Installation & Wiring Guide Doc. Ver. : V R&D Center Union Community Co., Ltd.
2 1. Power Connector connection Backup Battery Interface BAT(-) BAT(+) DC 15V OUT DC 15V OUT 15V 15V 12V G 12V G + - 5V G 12V G 15V 5V 15V DC 15V 6A Power Adapter DC 5V OUT DC 15V OUT
3 2. Main Board Feature SW301 Battery Power On Switch JP151/JP152 RS485 Termination Resistor Select Switch Switch Setting I [ Lock Type Selection ] JP201 : [ Normal Open Relay Contact ] [ Normal Close Relay Contact ] JP202 : [ Normal Open Relay Contact ] [ Normal Close Relay Contact ] JP203 : [ Normal Open Relay Contact ] [ Normal Close Relay Contact ] JP204 : [ Normal Open Relay Contact ] [ Normal Close Relay Contact ] Switch Setting II [ Lock Type Selection ] JP205 : Lock Power Contact / Lock No Power Contact JP206 : Lock Power Contact / Lock No Power Contact JP207 : Lock Power Contact / Lock No Power Contact JP208 : Lock Power Contact / Lock No Power Contact Switch Setting III [ RS485 T_Resistor Selection ] JP151 : ON [ 120ohm termination resistor ] OFF [ Open the termination resistor ] JP152 : ON [ 120ohm termination resistor ] OFF [ Open the termination resistor ] JP201~JP204 JP205~JP208 Lock Type Switch
4 3. Connection of Wires to terminal blocks 15V OUT BELL+ EXPA+ BELL- EXPB- RDRB- RDRA+ 15V OUT ZONE4/ZONE8 ZONE3/ZONE7 ZONE2/ZONE6 ZONE1/ZONE5 OUT6 OUT5 D13 D03 OUT2 OUT1 D11 D01 D01 D11 OUT1 OUT2 D03 D13 OUT5 OUT6 Z1/ Z5 G Z2/ Z6 Z3/ Z7 G Z4/ Z8 G G 12V G RDRA RDRB EXPA EXPB BELL+ BELL- 12V G D02 D12 OUT3 OUT4 D04 D14 OUT7 OUT8 / / / / 5V G IN1 G IN2 IN3 G IN4 12V G Ethernet 15V OUT IN4 IN3 IN2 IN1 5V OUT LOCK#4 LOCK#3 LOCK#2 LOCK#1 OUT8 OUT7 D14 D04 OUT4 OUT3 D12 D02 15V IN
5 4. Connecting Virdi Reader BELL- BELL+ EXPB- EXPA+ RDRB- RDRA+ J253 Virdi Reader Virdi Reader J252 or J254 12V ON OFF 1:RED : +15V Virdi Reader RDR ON OFF JP151 2:Black : 3:Green : 485A+ 4:Blue : 485B- Max Virdi Reader 8ea (AC6000*4EA + VS-R20D*4EA) *SR100 : DC 5V Input EXP JP152 RS-485 Termination Resistor Select S/W : SW151
6 5. Connecting Wiegand Reader J255 OUT2 OUT1 D01 D11 Wiegand Reader1 J255 OUT4 OUT3 D02 Wiegand Reader2 D12 J256 OUT6 OUT5 D03 D13 OUT8 J256 Wiegand Reader3 1:RED : +15V 2:Black : 3:Brown : Wiegand IN1 4:Pink : Wiegand IN0 5:Green : Buzzer or LED 6:Violet : Buzzer or LED OUT7 D04 Wiegand Reader4 D14 J252 or J254 12V
7 6. Connecting PGM(Open Collector) J VDC OUT2 OUT1 - Coil + D01 D11 J255 Relay OUT4 OUT3 D02 D12 J256 OUT6 OUT5 D03 D13 OUT8 OUT7 D04 D14 J256 - Coil + Relay Ensure a common ground is connected between relay power supply and MCP VDC
8 7. Connecting Zone
9 8. Connecting BELL/Siren J253 BELL- BELL+ EXPB EXPA RDRB RDRA Bell/Siren Bell Supervision Resistor 2200Ω 5%
10 9. Connecting Dead-Bolt Type Door Lock (Fail Safe) Z4/Z8 Z3/Z7 Z2/Z6 Z1/Z2 LOCK4 LOCK3 LOCK2 Red Black Green Gray Lock1 : Lock (+) : Lock (-) : Door Monitor () : Ground (Door Status Com) JP201 JP205 n IN4 IN3 IN2 IN1 J253 Open S/W4 Open S/W3 LOCK1 Lock3 Lock2 JP203 JP207 JP202 JP206 n n Lock Type Select S/W Open S/W2 JP204 Open S/W1 Lock4 JP208 n
11 10. Connecting Dead-Bolt Type Door Lock (Fail Safe) Z4/Z8 Z3/Z7 Z2/Z6 Z1/Z2 LOCK4 LOCK3 LOCK2 **Use external DC Power adapter Lock1 Red Black Green Gray JP201 JP205 n : Lock (+) : Lock (-) : Door Monitor () : Ground (Door Status Com) IN4 IN3 IN2 IN1 J253 (+) External(-) Power Open S/W4 Open S/W3 Open S/W2 Open S/W1 LOCK1 Lock2 Lock3 Lock4 JP202 JP206 JP203 JP207 JP204 JP208 n n n Lock Type Select S/W
12 11. Connecting EM Type Door Lock (Fail Safe) Z4/Z8 Z3/Z7 Z2/Z6 Z1/Z2 IN4 IN3 IN2 IN1 J253 Open S/W4 Open S/W3 Open S/W2 LOCK4 LOCK3 LOCK2 LOCk1 Lock1 Lock2 Lock3 Lock4 JP201 JP205 JP202 JP206 JP203 JP207 JP204 JP208 Red Black Orang e n n n : Lock (+) : Lock (-) : Door Monitor Lock Type Select S/W Open S/W1 n
13 12. Connecting EM Type Door Lock (Fail Safe) Z4/Z8 Z3/Z7 Z2/Z6 Z1/Z2 **Use external DC Power adapter LOCK4 LOCK3 LOCK2 Lock1 JP201 JP205 Red Black Orang e n : Lock (+) : Lock (-) : Door Monitor IN4 IN3 IN2 IN1 J253 (+) External(-) Power Open S/W4 Open S/W3 Open S/W2 Open S/W1 LOCk1 Lock2 Lock3 Lock4 JP202 JP206 JP203 JP207 JP204 JP208 n n n Lock Type Select S/W
14 13. Connecting Strike Type Door Lock (Fail Safe) LOCK4 Red Black Orange : Lock (+) : Lock (-) : Door Monitor Z4/Z8 Z3/Z7 Z2/Z6 Z1/Z2 LOCK3 LOCK2 Lock1 JP201 JP205 n IN4 IN3 IN2 IN1 J253 Open S/W4 Open S/W3 Open S/W2 Open S/W1 LOCK1 Lock2 Lock3 Lock4 JP202 JP206 JP203 JP207 JP204 JP208 n n n Lock Type Select S/W
15 14. Connecting Strike Type Door Lock (Fail Safe) Z4/Z8 Z3/Z7 Z2/Z6 Z1/Z2 LOCK4 LOCK3 LOCK2 **Use external DC Power adapter Lock1 Red Black Orange JP201 JP205 n : Lock (+) : Lock (-) : Door Monitor IN4 IN3 IN2 IN1 J253 (+) External(-) Power Open S/W4 Open S/W3 Open S/W2 Open S/W1 LOCK1 Lock2 Lock3 Lock4 JP202 JP206 JP203 JP207 JP204 JP208 n n n Lock Type Select S/W
16 15. Connecting Auto-Door ( Contact Control ) Auto Door Operating Part Auto Door Motor Auto Door Operating Part Auto Door Motor Sensor Input Line Sensor Input Line Auto-Door Sensor N.O. Auto-Door Monitor Auto-Door Sensor N.O. Auto-Door Monitor LOCK4 Auto Door Operating Part Auto-Door Sensor Sensor Input Line Auto Door Motor N.O. Open S/W Auto-Door Monitor Auto Door Operating Part Auto-Door Sensor LOCK3 Sensor Input Line Open S/W Auto Door Motor N.O. Auto-Door Monitor Lock1 Lock2 Lock3 Lock4 JP201 JP205 JP202 JP206 JP203 JP207 JP204 JP208 n n n n Lock Type Select S/W LOCK1 Open S/W LOCK2 Open S/W
17 16. Wiring Guide System Overview
18 18. Wiring/Cable Recommendations 1. RS485 (RDR+, RDR-) 22AWG 2 Pair Twisted, Mylar screened Home run, maximum distance 1000m 2. Ethernet Standard CAT5 cable Note: Cross over cable is required for direct connection to PC 3. Lock Monitoring, IN1-4, OUT1-8, ZN1-8 22AWG~24AWG 2 Pair Twisted, Mylar screened Vdc Supply to Readers, Locks, etc 22AWG 2 Pair Twisted, Mylar screened 300ma, 22AWG = 250meters, voltage at device ~ 11.03Vdc 1000ma, 22AWG = 75meters, voltage at device ~ 11.03Vdc TE: If distance is to be exceeded then an external power supply should be used for powering the device. Voltage at the reader and locks should be higher than 11Vdc. Please visit for calculating approximate distance with current and voltage requirements for your device.
19 17. Factory Reset J252 or J254 12V J255 Resistor 2200Ω & 3900 Ω OUT2 OUT1 D11 D01 IN4 IN3 IN2 IN1 J253 1) Power down the MCP040. 2) Connect a wire between 12V+Resistor+OUT1+IN1 (J252/J255/J253). 3) Power up the MCP040. 4) After about one second remove the piece of wire. 5) All parameters and users will now be at factory reset state.
MINI-SA2. User Manual. Technical Characteristics. Mounting. Version 1.1 MINI-SA2
User Manual These low profile standalone proximity readers are able to read EM4002 type card / fobs and have capacity up to 4000 users. All electronics are self contained within the reader, therefore no
More informationLONG RANGE REMOTE RECEIVER WITH TRANSMITTER FOR BUNGALOWS AND BANKS MODEL KE - 2 L R
REMOTE RECEIVER DIMENSION : L = 90 MM X H = 75 X D = 38 MM. R F RANGE FOR TRANSMITTER AND RECEIVER IS 20 TO 30 METERS IN CLOSED AREA R F SIGNAL CROSSED WOODEN, R C C WALL, GLASS, AND METAL DOORS REMOTE
More informationP700WLS IoProx Receiver
Installation Manual Warning! This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual
More informationCopper Compression Lugs Conductor Size #8
A TYPE Conductor Size #8 Overall Catalog Wire Alt Bolt Overall Die Number Size Wire Size Size Thickness Color Code -8-10 8 AWG 8 FLEX #8-#10 0.579 0.445 0.071 1.201 RED 0.185 0.256-8-14 8 AWG 8 FLEX 1/4
More informationWLS-5500 Receiver (KSF & W26)
WLS-5500 Receiver (KSF & W26) Installation Manual DN1869-0912 Warning! This manual contains information on limitations regarding product use and function and information on the limitations as to liability
More informationMODEL Digital Ohm Meter. Instruction Manual
MODEL 3565 Digital Ohm Meter Instruction Manual I-01261 TSURUGA ELECTRIC CORPORATION 2 Contents 1. Preface... 3 1.1 Preparations prior to use... 3 1.1.1 Inspection... 3 1.1.2 Storage... 3 1.2 Confirmations
More informationData Acquisition Modules/ Distributed IO Modules
User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332
More informationSTRATUS CONTROLLER MANUAL September 14, 2015
STRATUS CONTROLLER MANUAL September 14, 2015 Fig.1 1 Wiring The controller runs on 24vdc. Inputs are all 24vdc. Outputs are both relay-out dry contact (J4, J5 and J7) and 24vdc current limited/short circuit
More informationCom-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide
Com-Trol ADV-6000 Trouble Shooting Guide Click on red text to go to that page in guide Topic Introduction 1 Tool Requirements 1 Trouble Shooting Check List 1 Page(s) Lost communications to controller(s)
More informationICM/ICAD Motorized Valve. Quick Start Guide. Installation, Programming, and Trouble-shooting REFRIGERATION & AIR-CONDITIONING
Installation, Programming, and Trouble-shooting REFRIGERATION & AIR-CONDITIONING Quick Start Guide Contents Page Installation...............................................................................................3
More informationP700-WLS ioprox Receiver
Installation Manual DN1628-1611 Pre-Installation Notes Copyright 2016 Tyco International Ltd. and its Respective Companies. All Rights Reserved. All specifications were current as of publication date and
More informationActuator ICAD 600A / ICAD 600A-TS / ICAD 1200A
Installation Guide Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A 027R9966 ICAD 600A ICAD 600A-TS ICAD 1200A 027R9966 ICAD 600A / ICAD 600A-TS ICAD 1200A Fig. 1 Fig. 2 Note: When mounting the ICAD make
More informationDesign and Technology
E.M.F, Voltage and P.D E.M F This stands for Electromotive Force (e.m.f) A battery provides Electromotive Force An e.m.f can make an electric current flow around a circuit E.m.f is measured in volts (v).
More informationDATE: NAME: CLASS: Drawing Circuit Diagrams
CHAPTER 8 BLM 315 Drawing Circuit Diagrams Goal Practise drawing circuit diagrams. For each of the following circuit illustrations, draw its corresponding circuit diagram and answer the questions that
More informationConnection and Operation (Built-In Controller Package)
(Built-In Controller Package) Names and Functions of Parts Power Supply Input Terminal (CN1) Regeneration Unit Thermal Input Terminal (CN1) Electromagnetic Brake Terminal (CN1) Motor Connector (CN2) CHARGE
More informationCyclops User s Manual
Cyclops User s Manual Revision 5.x.x March 14, 2017 Contents Background... 1 Interface... 1 Normal Operation... 1 Controller Input Type... 1 Communication... 2 Sensitivity... 3 Operating Modes... 3 Normal...
More information1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.
Fig. 1 Lock/ unlock 30 1000 Light 1 100 300 zone 1 Learn actual lux LED 600 2000 0,4 0,6 0,8 1,0 1,2 Time 1 Light 2 zone 2 1,4 1,6 Factor of lux zone 1 Pulse 2min 5min Time Time 2 10min 15min 30min 1 2
More informationBlue Point Engineering
DMX Data Analyzer Board nstruction Overview DMX Analyzer - Tester PC Board Design your own enclosure with an analyzer / tester display or add to your existing equipment or system. The DMX Analyzer is a
More informationA Super trainer with advanced hardware and software features only found in very expensive equipment.
PLC Trainer PTS T100 LAB EXPERIMENTS A Super trainer with advanced hardware and software features only found in very expensive equipment. You won t find any similar equipment among our competitors at such
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current
More informationInstruction. Actuator ICAD 600 / ICAD 900 / ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 ICAD 600 ICAD 900. ICAD 1200 Fig. 2. Fig. 4
Instruction 027R9796 027R9796 Actuator ICAD 600 / ICAD 900 / ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 Fig. 1 Fig. 2 Note: When mounting the ICAD make sure to push ICAD down to
More informationmulti-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER
multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER Model : DI-6400 Your purchase of this INSULATION TESTER marks a step forward for you into
More informationInstallation Tech Note Dallas, Texas
AMC B40A40AC Installation Tech Note Dallas, Texas May, 2010 ! CAUTION! Do NOT apply air pressure to release the collet while the servo motor is rotating. The servo motor spindle must be FULLY STOPPED before
More informationThis product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.
The equipment described in this manual contains high voltage. Always disconnect power to the equipment before installing, disconnecting, or servicing the product. This product is for use in a dry, indoor
More informationModel RFT9709 Transmitter Instruction Manual
Model RFT9709 Transmitter Instruction Manual March 1999 Model RFT9709 Transmitter Instruction Manual For technical assistance, phone the Micro Motion Customer Service Department: In the U.S.A., phone
More informationICM/ICAD Motorized Valves Installation, Programming, and Troubleshooting
Quick Start Guide ICM/ICAD Motorized Valves Installation, Programming, and Troubleshooting The ICM motorized valve is comprised of up to 4 components: the valve body often referred to as the ICV body because
More informationUPS - modules serve for the buffering of a voltage for a certain period.
DC-UPS 100 Module DC - UPS 100 BRIEF DESCRIPTION UPS - modules serve for the buffering of a voltage for a certain period. B The modules contain the following functional groups: Power Fail: At power failure
More informationPID500 FULL FEATURED PID TEMPERATURE CONTROLLERS
PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS DESCRIPTION FEATURES * Compact Size: 1/16 DIN * Dual LED displays for simultaneous indication of process temperature and set point (Lower display selectable
More informationHANDS-FREE KEYLESS ENTRY AUTHF500
Mount in Dry Location Install Fuses Good Required Use High Amp Relay Remote Transmitter Turn power on. For a successful communication between the main unit and transmitter the on the transmitter will blink
More informationParts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt.
Quick Start Guide Backplate Backup Key Battery Cover Touchscreen Assembly Parts Strike Bolt Inside Assembly Thumbturn Reinforcement Plate Set Screw Reinforcement Screws Inside Assembly Screw Backplate
More informationIndexer unit JUSP-NS600. System configuration. Smart and simple positioning solution.
Smart and simple positioning solution. No programming languages are required. Connects directly to the drive Allows serial network control and discrete I/O control Servo axis set-up, actuation and monitoring
More informationOhm's Law and DC Circuits
Physics Lab II Ohm s Law Name: Partner: Partner: Partner: Ohm's Law and DC Circuits EQUIPMENT NEEDED: Circuits Experiment Board Two Dcell Batteries Wire leads Multimeter 100, 330, 560, 1k, 10k, 100k, 220k
More information2304 EN. High-Precision Automatic Inspection and Test Unit for Electrical Resistance Testing RESISTOMAT. Automatic inspection and test unit
High-Precision Automatic Inspection and Test Unit for Electrical Resistance Testing RESISTOMAT Model 2304 Code: Delivery: Warranty: ex stock 24 months Automatic inspection and test unit Highest measuring
More informationMS2109A AC/DC Clamp Meter. User Manual. Contents
MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description
More informationGutor PxW AC UPS Designed for North American Market
Gutor PxW AC UPS Designed for North American Market PEW 5 200 kva single phase PDW 10 220 kva three phase Higher ratings upon request schneider-electric.com 2 schneider-electric.com schneider-electric.com
More informationAC/DC ELECTRONICS LABORATORY
Includes Teacher's Notes and Typical Experiment Results Instruction Manual and Experiment Guide for the PASCO scientific Model EM-8656 012-05892A 1/96 AC/DC ELECTRONICS LABORATORY 1995 PASCO scientific
More informationAuto Diagnosis Test #2 Review
Auto Diagnosis Test #2 Review Your own hand written notes may be used for the 1 st 10 minutes of the test For the Most Effective Personal Review, Look Over the On Line Study Guide Multimedia Based on Chapters
More informationHow to use the UJ20 external inputs/outputs and modes / Troubleshooting
How to use the UJ20 external inputs/outputs and modes / Troubleshooting Page Title 1 How to use the UJ20 external inputs/outputs and modes / Troubleshooting 2 Emergency stop of UV irradiation 1: EMERGENCY
More informationPROMUX Distributed MODBUS I/O Modules Catalog and Design Guide
PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 14/11/2006 V10 P.O.Box 24 Stanfield 3613 SOUTH AFRICA Tel: +27 (031) 7028033 Fax: +27 (031) 7028041 Email: proconel@proconel.com Web: www.proconel.com
More informationOver or Under Current. Over and Under Current Monitor. Current Transducer. Current Indicator. DIN Rail Mounting Current Monitors
Selection Guide...8.2 Over or Under ECS... 8.4 TCS... 8.8 Over and Under Monitor ECSW... 8.6 Transducer TCSA... 8.10 DCSA... 8.12 Indicator LCS... 8.14 LPM... 8.14 DIN Rail Mounting CM-SFS CM-SRS.1 CM-SRS.2
More informationExplosion Proof Page/Talk Paging Amplifier
Industrial Communications Worldwide Explosion Proof Page/Talk Paging Amplifier Installation & Operation 7552-10 th Street. N.E. Calgary Alberta, Canada T2E W1 Ph: 403.25.3100 \ email:info@guardiantelecom.com
More informationSeries and Parallel Resistors
Lab 8. Series and Parallel Resistors Goals To understand the fundamental difference between resistors connected in series and in parallel. To calculate the voltages and currents in simple circuits involving
More information5v AC R. 12v. 1kohm. F=35KHz oscilloscope. 3 Final Project OFF. ON Toggle Switch. Relay 5v 2N3906 2N uF LM311. IR Detector +5v GND LED PNP NPN
3 Final Project Diode 103 IR Detector OFF ON Toggle Switch IR Detector +5v Push Button IR 100uF LED + GND LDR C Preset R 7805 IN GND OUT Relay 5v + PNP 2N3906 1 Kohm NPN 2N3904 4 3 2 1 555 5 6 7 8 4 3
More informationInstallation Instructions RF5910
Installation Instructions RF5910 HES, Inc. 22630 N. 17th Ave. Phoenix, AZ 85027 800-626-7590 1 Product Description Dimensions Orientation Compatibility Access Control Systems Proximity Cards Frequency
More informationNetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00
NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www
More informationPart V: Requirements and Test Methods for Magnetic Output from Handset Telephones for Hearing Aid Coupling
Issue 9 November 2004 Spectrum Management and Telecommunications Policy Compliance Specification for Terminal Equipment, Terminal Systems, Network Protection Devices, Connection Arrangements and Hearing
More informationPowerPlex Compact Module PP-C-COM24
Description The PowerPlex Compact Module has been designed for the 12 V or 24 V DC-System of special vehicles, buses or boats. It provides inputs for switches and sensors as well as power outputs with
More informationWEC200 Wiegand to Ethernet
WEC200 Wiegand to Ethernet Converter/Controller User Manual Version 1.0R5 Contents Chapter 1 General Information Chapter 2 Introduction Chapter 3 Installation Chapter 4 Pin Assignment Chapter 5 How to
More informationCable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 NS500 JUSP-NS500 SERVOPACK. 200V Ver.
JUSP- unit connectivity with positioning functionality. Connects directly to the drive Simplifies distributed control and information management No programming languages are required. Various positioning
More informationAX1_manual_rev_11_UK.indd :37:22
AX1_manual_rev_11_UK.indd 1 09-09-2008 13:37:22 . You have selected a truly unique design with respect for archi- Congratulations choosing tectural values. Thank you! It has been an emotional adventure
More information3 AXIS RF ELECTROMAGNETIC FIELD METER
50 MHz to 3 GHz Radio Frequency Radiation Meters Electromagnetic Field strength measurement 3 AXIS RF ELECTROMAGNETIC FIELD METER Model : EMF-819 Your purchase of this RF EMF METER marks a step forward
More informationMotor 1- GENERAL DESCRIPTION
1- GENERAL DESCRIPTI TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 This document is the property of Teleco Automation Srl
More informationWIRING SCHEMATICS FOR SOFTWARE VERSIONS 5.13 AND HIGHER
55 S. Vineyard Avenue Ontario, CA 976 (909) 93-973 WIRING SCHEMATICS FOR SOFTWARE VERSIONS 5.3 AND HIGHER FOR CURTIS 39 CONTROLLER ON-ROAD VEHICLE CONVERSION FOR SINGLE AND WITH DUAL MOTOR APPLICATIONS
More informationSERIAL COMMUNICATION. IDTECK Home e-training Center Home Product Catalog Product Manual Troubleshooting Purchase Order
1 SERIAL COMMUNICATION IDTECK Home Home Product Catalog Product Manual Troubleshooting Purchase Order 1 1. COMMUNICATION CONFIGURATION TCP/IP Communication LAN, LAN, WAN, WAN, INTERNET HUB INTERNET LAN
More informationPower connections, minimum and maximum wiring capabilities, tightening torque
Wiring - power terminals Power Observe the cable cross-sectional areas recommended in the standards. The soft starter must be grounded to conform to the regulations concerning leakage currents. If the
More informationECB-103 BACnet B-ASC 10-Point Programmable Controllers
D a t a s h e e t BACnet B-ASC 10-Point Programmable Controllers Overview The is a microprocessor-based programmable controller designed to control terminal units such as fan coil unit, heat pump unit,
More informationRF Remote Control Unit SEAV
RF Remote Control Unit SEAV for LINAK TECH-systems Installation instructions Foreword Dear producer, Thank you for choosing an actuator system from LINAK. LINAK systems consist of high-tech products based
More informationBULLETIN # B
Page 1 of 9 BULLETIN # B-18-2002 From: Parts and Service Division Date: February 14, 2002 To: All Authorized Service Agencies SUBJECT: Convection Oven Controller Troubleshooting MODELS AFFECTED: All Garland
More informationNBU-1012 Square pulse flashlamp driver User Manual
rev 1.07/ 2009 02 03 NBU-1012 Square pulse flashlamp driver User Manual Overview / Applications Cooling NBU-1012 Square Pulse Flashlamp Driver is designed for simplification of solid-state laser systems
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 105U range of wireless I/O provides a low cost alternative
More informationSTANDARD WIRING DIAGRAMS FOR SMART MODEL 20
CODING SYSTEM FOR AV ACTUATOR WIRING DIAGRAMS There are 3 elements to the wiring codes used in AVA electric actuators: WIRING CODE 1 3 Wire system, single pole double throw, switching the live SPDT 2 3
More informationThis document is the property of Teleco Automation Srl who reserves all reproduction and copying rights
1- GENERAL DESCRIPTION Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter
More informationEY-EM 527: Remote I/O module, ecolink527
Product data sheet 94.078 EY-EM 527: Remote I/O module, ecolink527 How energy efficiency is improved Regulation, control, monitoring and optimisation of operational systems, e.g. room automation or HVAC
More informationBlue Point Engineering
lue Point Engineering Wizard - I Interface oard http://www.pesolutions.com (303) 651.3794 Pointing the Way to Solutions! Talking / Eye Moving Skull Connectors pplication Examples 7805 Eyeball Jar nimatronic
More informationA local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.
FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of telemetry modules provide remote monitoring
More informationOWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER
OWNER S MANUAL HH0308C AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the tester. Failure to understand and comply with safety rules and operating
More informationSRC-110 Series Zone Controllers with Modbus RTU
Product sheet CT2.142 Type SRC-110-MOD SRC-110 Series Zone Controllers with Modbus RTU The SRC-110 series controllers have been designed for zone heating and cooling control. The controllers have 3 analogue
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 905U Wireless Solutions for Process Applications New Products... New Solutions The ELPRO 905U range of wireless I/O provides a low cost alternative
More informationUNDERGROUND PASSIVE MAGNETIC DETECTION SYSTEM CMS & HWS CONFIGURATION WITH ADAPTIVE SENSITIVITY TECHNICAL DESCRIPTION
aldor ecotec Ltd. Integrated Security systems UNDERGROUND PASSIVE MAGNETIC DETECTION SYSTEM CMS & HWS CONFIGURATION WITH ADAPTIVE SENSITIVITY TECHNICAL DESCRIPTION The material in this document is proprietary
More informationTroubleshooting Guide. MTS - type Systems for RV's
MOBILE THEATRE SYSTEM Troubleshooting Guide VERSION 1.1 For All MTS - type Systems for RV's River Park Inc. 21953 Protecta Dr Elkhart, In. 46516 (219) 522-7781 (219) 295-8780 www.riverparkinc.com 1 A.
More informationTechnical Document. for the. CB 016N6 Driver Card
Technical Document for the CB 06N6 Driver Card Contents Introduction 3 Page New functions 3 3 Dimensions 3 4 I/O Interface 4 5 Connectors 4-5 6 Switches 5-6 7 Potentiometers 7 8 LEDs and Error Indications
More informationDEIF A/S. Application Notes. Basic Gen-set Controller. Single generator set. Automatic mains failure. Parallel with mains (grid)
Basic Gen-set Controller 4189340316B Single generator set Automatic mains failure Parallel with mains (grid) DEIF A/S Load sharing multiple sets DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45
More informationSafety Relay Unit. OFF-delay time
Safety Relay Unit The Series Offers a Complete Line-up of Compact Units. Four kinds of -mm wide Units are available: A -pole model, a -pole model, and models with poles and OFF-delay poles, as well as
More informationInstallation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY
CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CLASS MODEL SERIAL HP Installation Manual Use this manual for circuit
More informationTelalarm HF-2 Handsfree Emergency Autodial Telephone
Telalarm HF-2 Handsfree Emergency Autodial Telephone INSTALLATION and OPERATIONAL INSTRUCTIONS (Firmware revision #020700 Rev. A HF2XTRA) with 10 number rollover 255 Glider Circle Corona, CA 92880 (800)
More informationHF-2 MiniTower Emergency Assistance Lighted Tower
Emergency Assistance Lighted Tower Standard HF-2 Operation INSTALLATION and OPERATIONAL INSTRUCTIONS 255 Glider Circle Corona, CA 92880 (800) 842-7444 Info@trigonelectronics.com www.trigonelectronics.com
More informationANSWERS AND MARK SCHEMES. (a) A base 1 B collector 1 C emitter 1. (b) = 2.82 ma 1. (c) Zero or very low current 1
QUESTIONSHEET 1 (a) A base 1 B collector 1 C emitter 1 (b) 0.12 + 2.7 1 = 2.82 ma 1 (c) Zero or very low current 1 QUESTIONSHEET 2 (a) TOTAL / 6 Thermistor in place 1 Thermistor symbol correct 1 Fixed
More informationDetcon Model FP Transmitter Test Fixture Operators Instruction Manual June 17, 2008 * Document 3389 * Revision 1.1
Operators Instruction Manual June 17, 2008 * Document 3389 * Revision 1.1 DETCON, Inc. 3200 Research Forest Dr., Building A-1 The Woodlands, Texas 77387 Ph. 713-559-9200 / Fax 281-298-2868 www.detcon.com
More informationBRU-100 Physical Installation
APPENDIX B BRU-100 In This Appendix: Warnings and Cautions, page 50, page 51 Check List, page 57 This appendix provides guidance for the physical installation of the BRU-100 Remote Unit at a subscriber
More informationLoad Cell Accessories and Services
Load Cell Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Mounting accessories Calibration services PCB Piezotronics, Inc. Toll-Free in USA 888-684-0004 716-684-0001
More informationUNIT E1 (Paper version of on-screen assessment) A.M. WEDNESDAY, 8 June hour
Candidate Name GCSE 46/0 Centre Number Candidate Number 0 ELECTRONICS UNIT E (Paper version of on-screen assessment) A.M. WEDNESDAY, 8 June 20 hour For s use 46 0000 Total Mark ADDITIONAL MATERIALS Information
More informationSWP-200- Digi Monitor 1/2 Antenna Switch Controller For Use with the DPS-100D Power Monitor System
Broadcast Devices, Inc. Technical Reference Manual SWP-00- Digi Monitor / Antenna Switch Controller For Use with the DPS-00D Power Monitor System READ THIS MANUAL IN ITS ENTIRETY BEFORE ATTEMPTING INSTALLATION
More informationInstallation guide Electronic superheat controller - Modbus version Type EKD 316C (Colibri )
ENGINEERING TOMORROW 084R8047 Installation guide Electronic superheat controller - Modbus version Type (Colibri ) English Introduction EKD 316 is a superheat controller that can be used where there are
More informationK-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions
F5140 and Programming Kit F5141 8635 Washington Avenue Racine, WI 53406 USA Tel: 800-433-5263 or 262-639-6770 Fax: 800-245-3569 or 262-639-2267 E-Mail: flo-techsales@racinefed.com www.flo-tech.com TABLE
More informationPIM400-TD2. User guide for Panel Interface Module PIM400-TD2
P516-096 PIM400-TD2 User guide for Panel Interface Module PIM400-TD2 Para el idioma español, navegue hacia www.schlage.com/support Pour la portion française, veuillez consulter le site www.schlage.com/support
More informationT6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224
T and T+ are trade names of Trol Systems Inc. TSI reserves the right to make changes to the information contained in this manual without notice. publication /4A115MAN- rev:1 2001 TSI All rights reserved
More informationCitilog XCOM-TS2 and XCOM-TS2-EXT. Interface Boards for Citilog XCAM-P specifications
Citilog XCOM-TS2 and XCOM-TS2-EXT Interface Boards for Citilog XCAM-P specifications 1.1. FUNCTIONALITIES The XCom-TS2 allows: interfacing up to 6 XCam s to a traffic controller 3 connection options to
More informationINTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series
OPERATION MANUAL INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series VOICE ALARM SYSTEM AMPLIFIER VM-3240VA VOICE ALARM SYSTEM AMPLIFIER VM-3360VA VM EXTENSION AMPLIFIER VM-3240E VM EXTENSION AMPLIFIER VM-3360E
More information4 CHANNEL TWISTED PAIR CABLE Rs485 BASED REMOTE CONTROLLER
4 CHANNEL TWISTED PAIR CABLE Rs485 BASED REMOTE CONTROLLER 4 Channel 2 core twisted pair remote controller built using PT2262, PT2272-M4 IC from Princeton technology and MAX485 IC from Maxim. PT2262 is
More informationExperiment 1: Circuits Experiment Board
01205892C AC/DC Electronics Laboratory Experiment 1: Circuits Experiment Board EQUIPMENT NEEDED: AC/DC Electronics Lab Board: Wire Leads Dcell Battery Graph Paper Purpose The purpose of this lab is to
More informationCopper Compression Lugs Conductor Size #8
Conductor Size #8 Overall Catalog Wire Alt Bolt Overall Die Number Size Wire Size Size Thickness Color Code -8-10 8 AWG 8 FLEX #8-#10 0.579 0.445 0.071 1.201 RED 0.185 0.256-8-14 8 AWG 8 FLEX 1/4 0.579
More informationWEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K
O P E R A T I N G I N S T R U C T I O N S WEL-200 TM W I R E L E S S E D G E L I N K 4564 Johnston Parkway, Cleveland, Ohio 44128 P. 800 426 9912 F. 216 518 9884 Sales Inquiries: salessupport@emxinc.com
More informationSCHLAGE WIRELESS ACCESS SYSTEM (WAS)
CONFIGURING & OPERATING INSTRUCTIONS SCHLAGE WIRELESS ACCESS SYSTEM (WAS) The most current version of this document is available for download at: http://www.ir-swa.com P/N: M053-007-D Schlage 245 W. Roosevelt
More informationLaboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor
Laboratory Grade Instruments 4020 Series & 4021 Power Meter Semiconductor 4020 SERIES Power Sensor 4021 4022 4024 4025 Power Input 300 mw to 1 kw 300 mw to 1 kw 3 W to 10 kw 3 W to 10 kw (1.2 kw max.)
More informationThe wireless alternative to expensive cabling...
The wireless alternative to expensive cabling... ELPRO 105U ISO 9001 Certified New Products... New Solutions The ELPRO 105 range of telemetry modules provide remote monitoring and control by radio or twisted-pair
More informationUser s Manual for Integrator Short Pulse ISP16 10JUN2016
User s Manual for Integrator Short Pulse ISP16 10JUN2016 Specifications Exceeding any of the Maximum Ratings and/or failing to follow any of the Warnings and/or Operating Instructions may result in damage
More informationF2A3X Frequency to Analog Converter Module
the professional s choice F2A3X Frequency to Analog Converter Module Instruction Manual MONARCH INSTRUMENT 15 Columbia Drive Amherst, NH 03031 USA Phone: (603) 883-3390 Fax: (603) 886-3300 E-mail: support@monarchinstrument.com
More informationg GE POWER MANAGEMENT
469 FREQUENTLY ASKED QUESTIONS 1 Can not communicate through the front port RS232 Check the following settings Communication port on your computer ( com1, com2 com3 etc ) Parity settings must match between
More informationGuardian and DL3282 Modem Interface Technical Service Application Note
Guardian and DL3282 Modem Interface Technical Service Application Note OVERVIEW The following document is designed to provide information for the implementation of the Guardian Wireless Modem/Analog Radio
More information