1 REMOTE RECEIVER DIMENSION : L = 90 MM X H = 75 X D = 38 MM. R F RANGE FOR TRANSMITTER AND RECEIVER IS 20 TO 30 METERS IN CLOSED AREA R F SIGNAL CROSSED WOODEN, R C C WALL, GLASS, AND METAL DOORS REMOTE RECEIVER INSTALLATION = INSTALL REMOTE RECEIVER IN WOODEN CABINET, PLASTIC CASING OR FALSE CEILING AREA DON T KEEP IN METAL CASING.
2 ARRANGE 230 V A C SUPPLY FOR 12 V S M P S POWER SUPPLY. POWER SUPPLY FOR RECEIVER = 12 VOLT DC 2 AMP FOR LOCK DRIVE ONLY. OUT PUT = 12V DC OUT WITH DRY CONTACT OUTPUT COM, NC, NO. ARRANGE 14/36 GAUGE 4 CORE FLEXIBLE WIRE FOR REMOTE RECEIVER TO LOCK 2 CORE WIRE FOR LOCK AND OTHER 2 CORE WIRE FOR BUZZER OR LED INDICATION. SYSTEM MODE = ON, OFF OR DELAY WHICH IS CHANGEABLE BY JUMPER SETTING. DELAY TIME = 2.5 SEC, 5 SEC, 7.5 SEC, AND 10 SEC.SECONDS CAN BE SET BY JUMPER SETTING. DELAY MODE = ALL 4 BUTTON A, B, C & D WILL WORK WITH DELAY MODE. ON OFF MODE = REMOTE TRANSMITTER HAVING 4 SWITCHES A, B, C & D. A OR B FOR LOCK TURN TO ON AND C OR D FOR LOCK TURN TO OFF. PANIC ALARM = SAME FOR DC 12V OPERATED HOOTER OR SIREN MANUAL OPERATION = RECEIVER IS WORKING WITH CONNECTING PUSH TO ON SWITCH FOR DELAY AND ON OFF MODE ( GRAY AND WHITE WIRE ) THIS REMOTE RECEIVER WILL WORK WITH ANY ACCESS CONTROL SYSTEMS FOR OUT SIDE ENTRY ACCESS CONTROL WILL WORK AND FOR INSIDE REMOTE CONTROL WILL WORK GENERALLY WHEN WE USE ACCESS CONTROL, LOCK IS ALREADY CONNECTED WITH ACCESS CONTROL AFTER THAT WE ONLY HAVE TO CONNECT DRY CONTACT WIRE GREEN AND BLUE PARALLEL TO ACCESS CONTRAL EXIT SWITCH WIRE AT THAT TIME DELAY TIME MUST SET 2.5 SECONDS.
3 IN THIS REMOTE RECEIVER WE CAN PROGRAMME MAXIMUM 8 TRANSMITTER REMOTE TRANSMITTER PROGRAMMING PROCEDURE 1 ALL 1 TO 8 TRANSMITTER WILL BE KEPT READY FOR PROGRAMMING. 2 TURN REMOTE RECEIVER POWER ON. 3 PRESS PROGRAMME SW 5 SECOND. 4 YELLOW LED WILLBLINK ON AND OFF. 5 WITH IN 3 SECONDS PRESS REMOTE TRANSMITTER A BUTTON FOR 2 SECONDS YELLOW LED WILL BLINK ON AND OFF THEN RELEASE A BUTTON. THIS PROCEDURE WILL REPEAT 8 TIMES, AFTER 8 TIMES PRESS AND RELEASE TRANSMITTER A BUTTON, BOTH BLUE AND YELLOW LED WILL BLINK ON AND OFF THAT MEANS ALL 1 TO 8 TRANSMITTER PROGRAMMED SUCCESSFULLY. 6 FOR EXAMPLE : IF PROGRAMME 2 TRANSMITTER 7 PRESS PROGRAMME SW 5 SECOND. 8 BLUE LED WILL BLINK ON AND OFF 9 WITH IN 3 SECOND PRESS 1 ST REMOTE TRANSMITTER A BUTTON FOR 2 SECOND YELLOW LED WILL GO ON AND OFF RELEASE A BUTTON, AGAIN PRESS 1 ST TRANSMITTER A BUTTON FOR 2 SECONDS AGAIN YELLOW LED WILL GO ON AND OFF THIS PROCEDURE FOR 1 ST REMOTE TRANSMITTER 4 TIME AND ANOTHER 4 TIME FOR 2 ND TRANSMITTER TO
4 COMPLETE REMOTE TRANSMITTER PROGRAMMING BOTH YELLOW AND BLUE LED WILL BLINK ON AND OFF. 10 IF 3 TRANSMITTER PROGRAMMING ST TRANSMITTER A, A, BUTTON PRESS, 2 ND TRANSMITTER A, A, 3 RD TRANSMITTER A, A, AGAIN 1 ST TRANSMITTER A, A BUTTON PRESS BOTH BLUE AND YELLOW LED WILL GO ON AND OFF. 12 IF 4 TRANSMITTER PROGRAMMING 13 1 ST TRANSMITTER A, A BUTTON PRESS, 2 ND TRANSMITTER A, A, 3 RD TRANSMITTER A, A, AND 4 TH TRANSMITTER A A BUTTEN PRESS, BOTH YELLOW AND BLUE LED WILL GO ON AND OFF.THAT MEANS ALL 4 TRANSMITTER IS PROGRAMMED SUCCESSFULLY. WIRING CONNECTION FOR REMOTE RECEIVER 1.BLACK WIRE : TO 0 VOLT SMPS POWER SUPPLY 2.BROWN WIRE : TO 12 VOLT DC + SMPS POWER SUPPLY 3. RED WIRE : +12 VOLT DC OUT FOR YALE TYPE DOOR STRIKE 4. ORANGE WIRE : 0 VOLT FOR DORR STRIKE, E M LOCK OR DROP BOLT 5. YELLOW WIRE : +12 VOLT OUT FOR E M LOCK OR DROP BOLT LOCK 6.GREEN WIRE : N O DRY CONTACT OUT PUT 7.BLUE WIRE : COM DRY CONTACT OUT PUT 8.VIOLET WIRE : N C DRY CONTACT OUT PUT 9.GRAY WIRE : PUSH TO ON SWITCH ( DRY CONTACT ) 10.WHITE WIRE : PUSH TO ON SWITCH ( DRY CONTACT )
5
6 REMOTE RECEIVER WITH ACCESS CONTROL WIRING CONNECTION WITH LOCK. LOCK CONNECD WITH ACCESS CONTROL. REMOTE RECEIVER WIRING CONNECTION WITH LOCK EXIT SW AND S M P S REMOTE RECEIVER WITH ACCESS CONTROL WIRING CONNECTION WITH LOCK. LOCK CONNECTED WITH REMOTE RECEIVER.
HANDS-FREE KEYLESS ENTRY AUTHF500
Mount in Dry Location Install Fuses Good Required Use High Amp Relay Remote Transmitter Turn power on. For a successful communication between the main unit and transmitter the on the transmitter will blink
More informationKICHFS1002 ONE TOUCH ENGINE START KIT WITH RFID. Parts Included: 1 ECO 1 HF500 1 KICSWBM22**
KICHFS1002 Parts Included: 1 ECO 1 HF500 1 KICSWBM22** Mount in Dry Location Install Fuses Good Ground Required Use High Amp Relay Remote Transmitter Turn power on. For a successful communication between
More informationMINI-SA2. User Manual. Technical Characteristics. Mounting. Version 1.1 MINI-SA2
User Manual These low profile standalone proximity readers are able to read EM4002 type card / fobs and have capacity up to 4000 users. All electronics are self contained within the reader, therefore no
More informationInstallation And Programming Instructions For Profile Series With RF Technology
Installation And Programming Instructions For Profile Series With RF Technology A7691A www.sargentlock.com 1 Table of Contents General Description Page 2 3 4 5 6 7 Installation of RF Technology Lock...1
More informationInstallation Manual. UL 325 Compliant. For Pre-2016 Convenience Open Operators ONLY
CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CFORMS TO ANSI/UL- CERTIFIED TO CAN/CSA C.. CLASS MODEL SERIAL HP CLASS MODEL SERIAL HP Installation Manual Use this manual for circuit
More informationOperating Instructions
LR650 Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product to. Comply with all
More informationInstructions for programming and use Starline Roldeck - floorpanel control RD-2001
Instructions for programming and use Starline Roldeck - floorpanel control RD-2001 Microprocessor-based Roldeck control Copyright Starline Technical Support BV. The Netherlands. Alle rechten voorbehouden.
More informationSERIES 6000 ELECTRIC STRIKES
SERIES 6000 ELECTRIC STRIKES Electric Strikes provide remote release of a locked door. They allow the door to be opened without retracting the latchbolt. This occurs by the releasing of the electric strike
More informationWireless Rain and Wireless Rain/Freeze Sensor
Wireless Rain and Wireless Rain/Freeze Sensor Installation and Operating Instructions for: WRC: Wireless Rain Sensor Combo WRT: Wireless Rain Sensor Transmitter WSR: Wireless Rain Sensor Receiver WRFC:
More informationFour Door Access Controller MCP-040 V2.0
Four Door Access Controller MCP-040 V2.0 Installation & Wiring Guide Doc. Ver. : V2.0 2014.10.23 R&D Center Union Community Co., Ltd. 1. Power Connector connection Backup Battery Interface BAT(-) BAT(+)
More informationTransmitter Programming Guide
Model PRO-OE4BS This transmitter makes use of icons (symbols) to identify the reaction your system will have when any icon (button) is pressed. These icons are programmed at time of installation to meet
More informationLock And Arm Alarm, also initiate and terminates *Panic.
Model 095BPr Transmitter Programming Guide These transmitters use icons (symbols) to identify the reaction your security system, keyless entry, and/or remote start system, where applicable, will have when
More informationWireless Data Gathering Panel MODEL TS0825
Wireless Data Gathering Panel MODEL TS0825 Wireless Data Gathering Panel: Model TS0825 INSTALLATION GUIDE The TS0825 Wireless Data Gathering Panel may be installed up to 1.5km from the Challenger panel
More informationSF Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications
Long Range Wireless Applications 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) The switch followers are a two way system designed to provide a quick and cost effective
More informationBlue Point Engineering
Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Puppet - II+ Controller (BPE No. PCA-0001) Servo Position Adjustment EEPROM Digital Button Power 5 Vdc Playback
More informationDIGITAL DIRECTION SENSING MOTION DETECTOR MANUAL
DIGITAL DIRECTION SENSING MOTION DETECTOR MANUAL DP-005 GLOLAB CORPORATION Thank you for buying our DP-005 Digital Direction Sensing Motion Detector The goal of Glolab is to produce top quality electronic
More informationInstallation Notes. SCR Single Channel
Installation Notes SCR Single Channel Receiver Part No. 100-187 Receives ARM / Disarm / PANIC / Low Batt channels from Ness Radio Keys or Radio PIRs / Radio Reeds. Supports up to four transmitters. Simple
More information601/602 Series Inductive Loop Detector
601/602 Series Inductive Loop Detector Installation Guide Sarasota Series Detectors 1 Copyright 2009 Peek Traffic Corporation Printed in the USA. All rights reserved. Information furnished by Peek is believed
More informationQuik Bridge Two- Channel Receiver Document Number: Rev. C September 1999
Quik Bridge Two- Channel Receiver Document Number: 466-547 Rev. C September 999 97G07A.DSF 60-760 INSTALLATION INSTRUCTIONS Product Summary The Quik Bridge Two-Channel Receiver allows two zones of a hardwired
More information58Khz ACOUSTO MAGNETIC SYSTEMS WIRING HANDBOOK
58Khz ACOUSTO MAGNETIC SYSTEMS WIRING HANDBOOK E.A.S. SISTEMAS ANTIHURTO, S.L. 1 Revisión 1 06/2012 1. INTRODUCTION. 2. SYSTEM DESCRIPTION. a. TRANSMITER ANTENNA TX. b. RECEIVER ANTENNA RX. c. POWER SUPPLY.
More informationMarantec bi linked Radio Accessories Service
Marantec bi linked Radio Accessories 1 45 Service 2015.08 Impressions transmitters 2 45 Service 2015.08 Impressions wall controls 3 45 Service 2015.08 bi linked technology Simple encoding (e. g. Multi-Bit)
More informationAKR-1. Digital Keyless Entry System With Built-in Wireless Receiver. Installation and Programming Instructions
AKR-1 Digital Keyless Entry System With Built-in Wireless Receiver Installation and Programming Instructions (760) 438-7000 FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX
More informationUser Manual Information and Product Description. of the. Flap Key Family BOSCH. with Chevy, GMC and GM Logo
User Manual Information and Product Description of the Flap Key Family BOSCH with Chevy, GMC and GM Logo Page 1 of 7 General Description of the RF transmitter: The RF remote control system consists of
More informationWiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers.
Wiring Instructions for 10, 16 & 20 Function, 92 & 93 Series, FET Receivers. 92220.02E 1 1. The Receiver is designed to carry a maximum of 15 Amps. That is, for example,15 Amps through one output or 5
More informationWireless Temp/Setpoint & Override Room Transmitter
Overview The BAPI Wireless Combination Transmitter measures the room temperature and relative humidity and transmits the data at 418MHz or 433MHz RF to a receiver. Temperature setpoint and override button
More informationMotor 1- GENERAL DESCRIPTION
1- GENERAL DESCRIPTI TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 This document is the property of Teleco Automation Srl
More informationA.M. WEDNESDAY, 19 May minutes
Candidate Name Centre Number Candidate Number 0 GCSE 293/02 ELECTRONICS MODULE TEST E1 HIGHER TIER AM WEDNESDAY, 19 May 2010 45 minutes For s use Total Mark ADDITIONAL MATERIALS In addition to this examination
More informationNess MCR Multi-Channel Radio Receiver
Installer s MANUAL Ness MCR Multi-Channel Radio Receiver Installation and programming manual Revision 2.1 www.nesscorporation.com National Customer Service Centre Ph: 1300 551 991 customerservice@ness.com.au
More informationThis document is the property of Teleco Automation Srl who reserves all reproduction and copying rights
1- GENERAL DESCRIPTION Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter
More informationNEW DIGITAL PUMP LOAD CONTROL
NEW DIGITAL PUMP LOAD CONTROL Power sensor monitors true motor power Waterproof & rugged, large red LED display Compact enclosure with flexible fittings Easy front panel keypad set up Low and high setpoint
More informationBuilding the Sawdust Regenerative Receiver
Building the Sawdust Regenerative Receiver Introduction The Sawdust is a super regenerative receiver using the basic Armstrong design architecture. The receiver uses one toroidal transformer to provide
More informationThank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.
Instruction Manual TPSRF31 (181430) - BOSS TM Electronic RF Roomstat Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.
More informationInstruction Manual. StealthLock, Keyless Invisible Security
Instruction Manual 1 Thank you for purchasing StealthLock. StealthLock is an innovative solution for keyless invisible security. Using radio frequency technology, StealthLock allows you to secure almost
More informationStealthLock is designed to install and program easily and offers: StealthLock is recommended for use on cabinets made from:
Instruction Manual Thank you for purchasing StealthLock. StealthLock is an innovative solution for keyless invisible security. Using radio frequency technology, StealthLock allows you to secure almost
More informationCOD GB / 1.0 RBAND/UMS - RBAND/CSM
INTRODUCTION DESCRIPTION The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge is used. The system provides a wireless system replacing
More informationTransmitters & Receivers
Transmitters & Receivers Contents 4 Channel Multi-Function Receiver / Transmitter Set - 433.92 MHz with Onboard Relays RXPROR4...2 4 Channel Universal Wireless Receiver ALE-4RX...3 2 Channel Transmitter
More informationFX-CM. HQ Color Mark Sensor. Model Number Legend SALIENT FEATURES. Sensors. Proximity. Photoelectric. Sensors
HQ Color Mark Sensor SALIENT FEATURES 18mm ±2mm Pushbutton Teach RGB LED light source 8 Remote Memory Setting Shock Resistant casing - 50G Model Number Legend 1 2 3 4 5 1. Series 4. Output FX 2. Type CM:
More informationThe purpose of this procedure is to describe a method for using the Dranetz analyzer to commission transformer rated meters.
Metering Standards Title: BASIC USE OF DRANETZ ANALYZER FOR METER MS 8. Page: of 9.0 PURPOSE The purpose of this procedure is to describe a method for using the Dranetz analyzer to commission transformer
More informationMODEL NC221 MOBILE TWO-TONE SEQUENTIAL DECODER INSTRUCTION MANUAL
15385 Carrie Drive Grass Valley, CA 95949 Office: (530) 477-8400 Tech. Support: (530) 477-8402 FAX: (530) 477-8403 Sales: (800) 874-8663 Email: tech@norcommcorp.com Web:www.norcommcorp.com MODEL NC221
More informationPhotoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs
Photoelectrics, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs µ-processor controlled unit for up to 10 sets of photoelectric sensors Up to 10 independent outputs Self-diagnostic
More informationPOWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS
POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A
More informationES8000-S V-LOCK ELECTRICAL SPECIFICATION INSTALLATION INSTRUCTIONS
ES8000-S V-LOCK Part No. ES8000-221 - 1116 INSTALLATION INSTRUCTIONS IMPORTANT Please read the instructions carefully prior to installation. It is important to follow the instructions precisely to ensure
More informationDP2500 DP0100 DP0250 Differential Pressure Transmitter
PB_DP_03 2011 DP2500 DP0100 DP0250 Differential Pressure Transmitter The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air
More informationGAME DESCRIPTION HOT SLOTS V6.00 COPY. (c) 2002 Version 6.00 Belgium
GAME DESCRIPTION HOT SLOTS V6.00 (c) 2002 Version 6.00 Belgium All information in these operating and game instructions were elaborated and compiled with the greatest care and checked using effective inspection
More informationOHM'S LAW AND RESISTANCE NETWORKS OBJECT
17 E7 E7.1 OHM'S LAW AND RESISTANCE NETWORKS OBJECT The objects of this experiment are to determine the voltage-current relationship for a resistor and to verify the series and parallel resistance formulae.
More informationT-1WF(V) Instruction Manual. Long Range LLC. 26 Tannery Street Franklin, NH 03235
T-1WF(V) Instruction Manual Long Range LLC. 26 Tannery Street Franklin, NH 03235 Introduction With the ability to fire targets and control the direction of your trap, the T-1WF transmitter is the perfect
More informationBAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions
Overview and Identification The BAPI-Stat 4 X-Combo () Room Unit features 4 output channels and optional local indication of temperature and humidity. Additional options include Temperature Setpoint, Humidity
More informationATS-I USER MANUAL. Tecnoelettra srl Dal Via Vioni Dimo, S.Rocco di Guastalla (RE)
USER MANUAL ATS-I Tel.+39.0522.832004 P1/17 ATS-I User manual Fax.+39.0522.832012 Tecnoelettra_EN.doc P.1/17 Index General description...3 Electrical specifics...3 Device operative logic...4 Manual mode...4
More informationCIRCUITS THAT ARE AVAILABLE ON LODAR RECEIVERS Features listed below are available on 92 Series and 93 Series
CIRCUITS THAT ARE AVAILABLE ON LODAR RECEIVERS Features listed below are available on 9 Series and 9 Series STOP CIRCUIT uses are: - OVER TEMPERATURE and OVER PRESSURE, etc. ALLOWS AN EXTERNAL SENSOR TO
More informationModel APS-2K4S and APS-2K4MS
Model APS-2K4S and APS-2K4MS Transmitter Programming Guide This transmitter makes use of icons (symbols) to identify the reaction your security system/keyless entry/and or remote start system, where applicable,
More informationWiring Diagram for Wireless 3-Valve Setup Live Pan
Wiring Diagram for Wireless 3-Valve Setup Live Pan Modify Wires The Live pan has no battery, so some of the wires Need to be modified 1. Locate the red wire form hard wired Controller and from the Wireless
More informationBuilding the Sawdust Regenerative Receiver
Building the Sawdust Regenerative Receiver Introduction The Sawdust is a super regenerative receiver using the basic Armstrong design architecture. The receiver uses one toroidal transformer to provide
More informationSlimline Standard Packages
Slimline Standard Packages Fast track delivery, ready to fit Note: Separate keeps are available for inward opening doors (see Additional Items ). Slimline Standard Packages Slimline Standard Packages include
More informationPS2-SMC-06 Servo Motor Controller Interface
PS2-SMC-06 Servo Motor Controller Interface PS2-SMC-06 Full Board Version PS2 (Playstation 2 Controller/ Dual Shock 2) Servo Motor Controller handles 6 servos. Connect 1 to 6 Servos to Servo Ports and
More informationGATE LIMIT RELAY KIT INSTALLATION INSTRUCTIONS GATE OPERATORS:
GATE LIMIT RELAY KIT INSTALLATION INSTRUCTIONS GATE OPERATORS: SW420/470/490, SL540/570/580/590 PARTS SUPPLIED Part # Qty Description 01-20322 1 Modification Instructions 27-20108 2 Cable Tie 76-20431
More informationExam Practice Problems (3 Point Questions)
Exam Practice Problems (3 Point Questions) Below are practice problems for the three point questions found on the exam. These questions come from past exams as well additional questions created by faculty.
More informationLock And Arm Alarm, also initiate and terminates *Panic
Model 07SPr Transmitter Programming Guide These transmitters makes use of icons (symbols) to identify the reaction your security system/keyless entry/and or remote start system, where applicable, will
More informationFMR MHz Receiver with Two Relay Outputs
FMR-202 27MHz Receiver with Two Relay Features Crystal Controlled 2-Channel Digitally Encoded Applications Remote control of garage doors, gates, lights, alarms Description The FMR-202 is a crystal controlled
More informationDP2500 DP0100 DP0250 Differential Pressure Transmitter
PB_DPT_03 2010 DP2500 DP0100 DP0250 Differential Pressure Transmitter The DP Low Differential Pressure Transmitter series is an accurate and cost competitive solution for measuring low pressures of air
More informationGPS&GPRS TRACKING SYSTEM GT3100
GPS&GPRS TRACKING SYSTEM GT3100 OPERATION/INSTALLER MANUAL REV: 2.0 (GT3100-special, V1.51, GT500-SIM340.C1) I. INTRODUCTION PORTMAN GPS GPRS tracking system GT3100 utilize the GPS tracking function and
More informationTCS2P125. Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual
TCS2P125 Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual Single Phase 2P 125 Amp Rated Voltage 250 Vac Patent Number : U.S. Pat. No. 7,557,683 KUTAI ELECTRONICS INDUSTRY CO.,
More informationSeries 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual
THE HIGH PERFORMANCE COMPANY Series 70 Hold 1 sec. Hold 1 sec. FOR MORE INFORMATION ON THIS PRODUCT AND OTHER BRAY PRODUCTS PLEASE VISIT OUR WEBSITE www.bray.com Table of Contents 1. Definition of Terms.........................................2
More informationModel 5WTX. Transmitter Programming Guide
Model 5WTX Transmitter Programming Guide These transmitters makes use of icons (symbols) to identify the reaction your security system/keyless entry/and or remote start system, where applicable, will have
More informationLazerpoint TM RF RX-91 Basic Receiver Installation Instructions
Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions Ver. 1.01 Section 1 General Description Camden Lazerpoint Radio Controls comprise the following models: - CM-TX-9 Wall switch ready transmitter
More informationCommercial Vehicle Productivity and Security. Antenna Configuration. External Antenna Installation (model 6650H only) Contigo 6650H/6651H Beacon
Commercial Vehicle Productivity and Security The 6650H/6651H is a versatile and economical GPS tracking beacon designed for fleet management needs in all commercial vehicles. The H designation in the model
More informationLab 4 Ohm s Law and Resistors
` Lab 4 Ohm s Law and Resistors What You Need To Know: The Physics One of the things that students have a difficult time with when they first learn about circuits is the electronics lingo. The lingo and
More informationShelti, Inc. 333 Morton Street Bay City, MI Phone Fax. Bayside Dollar Bill Acceptor Pool Table Manual & Instructions
Shelti, Inc. 333 Morton Street Bay City, MI 48706 989-893-1739 Phone 989-893-1809 Fax Bayside Dollar Bill Acceptor Pool Table Manual & Instructions Contents Section-1 Introduction Bayside DBA Pool Table
More informationGT SERIES. QuikStart Installation Guide #95228
#95228 GT SERIES QuikStart Installation Guide ATTENTI: This is an abbreviated Installation Manual, addressing wiring and programming of the GT Series. The complete GT Series Installation Manual is located
More informationAUDIO/VISUAL DEVICES WIRELESS. Audio/Visual Devices Wireless SMOKE DETECTION INDOOR SIRENS OUTDOOR SIRENS BEACONS. REMOTE CONTROLS Magnum Series
33 SMOKE DETECTION B0065 Smoke Detector Optical 4 Wire smoke detector, including base. 12VDC. AUDIO/VISUAL DEVICES INDOOR SIRENS B0143 Buzzer Buzzer, 12VDC B0062 Piezo Piezo (sound bomb) 12 VDC OUTDOOR
More informationBFS / BFSM SERIES Installation & Maintenance Manual
Introduction: The BFS / BFSM series electric actuators have battery backup modules for fail safe operation. The BFS series is for two position control and the BFSM series is for proportional control, both
More informationMotorized Screen with Masking Installation Manual
Motorized Screen with Masking Installation Manual Mounting Dimensions - Small Casing Ceiling Mount - Single Layer - 70-96 (16/9 format) - 70-90 (4/3 format) - 70-100 (2.35 format) PROJECTION SIDE 2.9"
More informationRemote Sensor Manual. User Guide. Revision A.0
Remote Sensor Manual User Guide Revision A.0 Contents Remote Sensor User Manual... 3 Connecting Power... 3 Basic Sensor Operation... 4 Basic Sensor Operation with Data Logging... 5 Sensor Calibration Button...
More informationLIGHT- INDUSTRIAL SLIDING GATE OPERATORS
D5-Evo, D10 and D10 Turbo Pocket System Configuration Guide TM TM TM LIGHT- INDUSTRIAL SLIDING GATE OPERATORS Prior to commissioning the system, please ensure that you have connected the wiring of all
More informationNEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :
NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE
More informationIMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.
PRODUCT DESCRIPTION IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment. The systems KRC11, 12, 13 and 14 consists of two parts: the transmitter
More informationTypical Wiring Connection Diagram 625DC1 RECEIVER 12VDC GROUND FROM REGULATED SOURCE 12VDC GROUND (BLACK WIRE)
625DC READ CAREFULLY BEFORE AND WHILE INSTALLING 625DC1 Typical use is for a SINGLE MOTOR SALT SPREADER WITH VIBRATOR CONTROL. NOTE TRANSMITTER HAS BEEN PROGRAMMED TO THE RECEIVER SEE PAGE 4 FOR PROGRAMING
More informationIRRIGATION 810-3R RECEIVER GUIDE
IRRIGATION 810-3R RECEIVER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 RECEIVER FUNCTION SWITCH SETTINGS 4 RECEIVER INDICATOR LIGHTS 4 SUPERVISION FEATURE 5 RECEIVER HOOKUP TO ENGINE DRIVEN WELL 6 RECEIVER HOOKUP
More informationTEAM DIGITAL. SMC4 Servo & Motor Controller
16 CV# Function/Default Value CV# Function/Default Value 28 reserved - 73 Servo 3 Behavior 0 29 Decoder Configuration 0 74 Servo 4 Behavior 0 30 reserved - 75 Output Flash 0 31 Ops Mode Loco Address 1
More informationDC Circuits. Date: Introduction
Group # Date: Names: DC Circuits Introduction In this experiment you will examine how to make simple DC measurements that involve current, voltage, and resistance. The current I through a resistor R with
More informationHAW-Arduino. Sensors and Arduino F. Schubert HAW - Arduino 1
HAW-Arduino Sensors and Arduino 14.10.2010 F. Schubert HAW - Arduino 1 Content of the USB-Stick PDF-File of this script Arduino-software Source-codes Helpful links 14.10.2010 HAW - Arduino 2 Report for
More information5v AC R. 12v. 1kohm. F=35KHz oscilloscope. 3 Final Project OFF. ON Toggle Switch. Relay 5v 2N3906 2N uF LM311. IR Detector +5v GND LED PNP NPN
3 Final Project Diode 103 IR Detector OFF ON Toggle Switch IR Detector +5v Push Button IR 100uF LED + GND LDR C Preset R 7805 IN GND OUT Relay 5v + PNP 2N3906 1 Kohm NPN 2N3904 4 3 2 1 555 5 6 7 8 4 3
More informationBlue Point Engineering
Blue Point Engineering Instruction I www.bpesolutions.com Pointing the Way to Solutions! Animatronic Wizard - 3 Board (BPE No. WAC-0030) Version 3.0 2009 Controller Page 1 The Wizard 3 Board will record
More informationET RXTX-RC Weatherproof Repeater Version 2011/010. Specifications. Encryption: Rolling Code. Frequency: MHz
ET RXTX-RC Weatherproof Repeater Version 2011/010 Specifications Encryption: Rolling Code Frequency: 433.92 MHz Transmitting range: Up to 900m (Line of sight, radio clutter free) Power input: 12 24V Ac/Dc
More informationQuik Bridge Loop Receiver Installation Instructions
Quik Bridge Loop Receiver Installation Instructions Support for a piezo (used for RF testing only) which, when used sounds the number of transmissions received from learned transmitters. Compatibility
More informationOPERATION MANUAL MOB 112
OPERATION MANUAL MOB 112 1 Contents 1 GENERAL... 4 1.1 Information regarding the operating instruction... 4 1.2 Limitation of liability... 4 1.3 Warranty... 5 2 TECHNICAL DATA... 6 2.1 Dimension... 6 2.2
More informationBellman BRUGERVEJLEDNING. Fyrtårn Flash BE1441
Bellman EN BRUGERVEJLEDNING Fyrtårn Flash BE1441 Introduction The Visit system consists of a number of radio transmitters and receivers. The transmitters detect different events in the surrounding area
More information4086B JWI CABINET PLACING AND REMOVING JUMPER WIRES
BELL SYSTEM PRACTICES SECTION 631 620-912CA Issue A, July, 1972 Bell Canada Standard 4086B JWI CABINET PLACING AND REMOVING JUMPER WIRES CONTENTS PAGE 1. GENERAL 585 2. OPENING CABINET 585 3. CONNECTOR
More informationINMOTION Controls Series INSTALLATION & OPERATION MANUAL. INMOTION Series - INMOTION INMOTION-260. Page: 1/15
INSTALLATION & OPERATION MANUAL INMOTION Series - INMOTION-220 - INMOTION-260 Page: 1/15 PREFACE This installation & operation manual is intended as an instruction manual for trained persons who are in
More informationREMEMBRANCE USER GUIDE DMX-512 AND ANALOG CONTROL STATIONS. User Guide. Copyright 2004 Leviton Manufacturing Co., Inc.
REMEMBRANCE DMX- AND CONTROL STATIONS USER GUIDE Copyright 00 Leviton Manufacturing Co., Inc. Leviton Control Stations Page of 0 DI-00X-RMB8-00A Page of 0 Leviton Control Stations Table of Contents System
More informationGUIDE & INSTALLATION MANUAL
Omega ECHO-3 2-Way Controller Transceiver OERATION GUIDE & INSTALLATION MANUAL COYRIGHT 2009: OMEGA RESEARCH & DEVELOMENT, INC. THE OMEGA ECHO-3 2-WAY TRANSCEIVER LCD Screen II II. rogramming Disarm/Unlock
More informationPLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No
PLUG N PLAY 1000 1000 WATT DIGITAL FM TRANSMITTER April, 2002 IM No. 597 9972 OPERATION/FEATURE PROGRAMMING. The PNP 1000 allows the user to select many types of different operating parameters and features.
More informationOPERATING MANUAL SESAM 800 MOBILE TAIL LIFT EN -D0
OPERATING MANUAL SESAM 800 MOBILE TAIL LIFT 942913-000 EN -D0 2 (16) Table of Contents 1 Introduction 3 2 Scope 3 3 Service 3 4 Maintenance 4 5 Technical Specifications 4 6 Short Description of the System
More informationLOGIC MODULES INTRODUCTION
INTRODUCTION With littlebits logic modules, you can program in block form. The logic modules create rules for your circuit to follow, giving you more ability to create interesting and complex interactions.
More informationGuidelines to Using a Three Phase Voltage Monitor
September 2000 Guidelines to Using a Three Phase Voltage Monitor Introduction A phase monitor can be used with any three phase motor. A monitor such as the Copeland 085-0160-00 is recommended for monitoring
More informationDC Circuits, Ohm's Law and Multimeters Physics 246
DC Circuits, Ohm's Law and Multimeters Physics 246 Theory: In this lab we will learn the use of multimeters, verify Ohm s law, and study series and parallel combinations of resistors and capacitors. For
More informationInstallation Instructions for CMS Pro Meter (with Breakout Box Type-A) for Yamaha V-Max 1700
Installation Instructions for CMS Pro Meter (with Breakout Box Type-A) for Yamaha V-Max 1700 Notes: (1) For the remainder of this document, Meter is referring to the Motoscope Pro Meter which comes with
More informationHC900 Remote Termination Panel (RTP) For Analog Inputs
HC900 Remote Termination Panel (RTP) For Analog Inputs Document umber: 515233134 Effective: 7/28/10 Supersedes: 6/8/05 Summary The Remote Termination Panel (RTP) provides an easy way to connect the HC900
More informationDIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL
DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A TABLE OF CONTENTS TITLE PAGE Safety Information Safety Symbols... 1 Meter Description...
More informationInstallation and Operating Guide
Alpha Watch 3 Platinum Alpha Watch 3 Gold Alpha Watch 3 Staff Installation and Operating Guide 2 nd Generation Equipment after 10/04/2004 1-800-735-9131 www.wandercontrol.com Alpha Watch 3 Platinum /Gold
More informationSS2 Linear / Rotary. Smart Valve Positioner. Smart performance with innovative and ever-strong coil drive even under harsh working environments
Smart Valve Positioner SS2 Linear / Rotary Smart performance with innovative and ever-strong coil drive even under harsh working environments Easy and quick auto-calibration Detecting RA (reverse acting)
More information