1 1 SERIAL COMMUNICATION IDTECK Home Home Product Catalog Product Manual Troubleshooting Purchase Order 1

2 1. COMMUNICATION CONFIGURATION TCP/IP Communication LAN, LAN, WAN, WAN, INTERNET HUB INTERNET LAN Converter 2 RS422 RS232 PSTN Dial-Up Communication RS422 to RS232 CONVERTER RS422 RS485/RS422 to RS232 CONVERTER Serial Communication RS485/RS422 2

3 2. RS232 COMMUNICATION 3 RS232C Communication Deployment RS232C : 1:1 connection between Access Controller and PC Maximum Communication Cable Length (PC to CONTROLLER) : 15M RS232C CONTROLLER RS232C Communication Wiring GND RXD TXD GND(NO.5) TX(NO.3) RX(NO.2) CONTROLLER CONTROLLER - Finger007 Series - 505R Series -icon100 Series -itdcseries - etc.. HOST PC 9pin D-SUB female connector 3

4 3. RS422 COMMUNICATION RS422 Communication Deployment Controller is considerably distant from PC Electric Noise is existing around communication line Maximum Communication Cable Length (converter to Finger007) 1,200m RS422(multi-drop) : Multi controllers are connected to one PC - Direct connection among Controllers - Cross connection between the Controller and the Converter (TX to RX, RX to TX) 4 RS422 RS232C RS422 to RS232 Converter Controller CROSS CONNECTION DIRECT CONNECTION 4

5 4. RS422 to RS232 CONVERTER 5 RS422(Controller) RS232(PC) Serial Cable Connector To Controller (RS422) INC400 CNP200 To Controller (RS422) 5

6 5. INC400 CONVERTER 6 INC400 A Type Connection INC400 B Type Connection Unit(RS422) INC400 Black wire Blue wire Unit(RS422) INC400 Red wire White wire Unit(RS422) INC400 R- (3) R+ (4) Unit(RS422) INC /(T-) (5) 485+/(T+) (6) 6

7 6. CNP200 CONVERTER 7 CNP200 Connection CROSS CONNECTION CNP200A 9 PIN 9 PIN 9 PIN HOST PC Unit(RS422) CNP200 Unit(RS422) CNP200 Blue wire Red wire Black wire White wire 7

8 7. COMMUNICATION CABLE Transmission Medium Generally used for serial communication 2 lines ( copper material) are used Each line is covered with colored plastic insulator 8

9 8. COMMUNICATION CABLE Twisted-pair cable UTP : Unshielded Twisted Paired Copper Cable FTP : (Overall) Foiled Twisted Paired Copper Cable STP : (Overall) Shielded (and Shielded Individually Pair) Twisted Paired Copper Cable UTP FTP STP UTP & STP Cable comparison Table STP (Shielded Twisted-Pair) Texture Shielded and Twisted paired Max Distance 100m (328Feet) Trans Speed 16Mbps (MAX 155Mbps) Ex Interruption Resistant to eletric Nose. Installation Not easy Cost High UTP (Unshielded Twisted-Pair) Unshielded Twisted Paired 100m (328Feet) 10Mbps (MAX 100Mbps) Delicate to electronic noise Easy to use Low 9

10 9. COMMUNICATION CABLE Recommendation Cable Serial Communication Cable (Good) - Belden 24AWG (No. 8106, 8103, 8162, 9729, 8102, 9829, 9842, 8162) - Belden 22AWG (No. 3107A, 3105A, ) Network Communication Cable (Normal) - Belden S/FTP Category 7 (No. 1885ENH) - Belden STP Category 5e (No. 1633ENH PLUS) - Belden FTP Category 6 (No. 7860ENH, 7860E) < Notice> - The number of Cable pair is changeable depending on communication type - Communication distance may be decreased by the condition of the installation site - Network Communication Cable is less secure than Serial Communication Cable Cable Range Between Host Controller (RS232C) Cable Standard RS232C 1.25mm 15m 0.75mm 15m 0.3mm 15m Cable Range Between Host Controller (RS422/485) Cable Standard RS232/RS mm 1,200m 0.75mm 1,000m 0.3mm 700m Standard UL UL UL Standard UL UL UL 10

11 10. RECOMMANDATION CABLE for CONFIGURATION 11 System Configuration NO. 1 2 * Description itdc Power (DC12V) DC Power itdc Reader (Power and Data) Extra Reader itdc Exit Button Door Contact Sensor Sensor Input itdc Door Lock, Alarm Device Lock (Alarm) itdc RS232 Cable Converter Host P.C. RS485 Cable itdc itdc itdc Converter RS422 Cable itdc itdc itdc Converter Recommendation Cable Belden #9409, 18 AWG 2 conductor, unshielded Belden #9512, 22 AWG 4 conductor, shielded Belden #9514, 22 AWG 8 conductor, shielded Belden #9512, 22 AWG 4 conductor, shielded Belden #9514, 22 AWG 8 conductor, shielded Belden #9409, 18AWG 2 conductor, unshielded Belden #9829, 24 AWG 2-twisted pair, shielded Belden #9829, 24 AWG 2-twisted pair, shielded Belden #9830, 24 AWG 3-twisted pair, shielded The thicker wire is necessary if the user connects the reader with high current consumption. Maximum Distance 30m 150m 300m 300m 15m 1,200m 11

12 11. GROUNDING(Earthing) 12 Definition To make an electric connection between electric devices and the ground Purpose To avoid lightening and static electricity To prevent Over flow of electricity or Over Voltage Stable system operation Cable Grounding Ground Loop No Ground Loop Grounding Point Ground Loop n No Current Path, No Ground Loop n Improper Cable grounding Ground Loop is being built - Potential difference in Ground flowing into Shield line Move to the communication line Electric Noise Proper Cable grounding Ground Loop is not built - Protected from the noise around the cable Grounding Point - Earth : Great - Chassis : Good - Power : Normal 12

13 12. CABLE GROUNDING 13 Power PANEL <01> Power PANEL Open Ground Point Earth Ground <02> Chassis Ground - Connect shield lines to GND of Controller Power PANEL Power Ground - Chassis Ground must be connected to Earth Ground <3> AC Power DC Power RS232 Cable RS422 Cable wire RS422 Cable shield RS422 Cable PVC cover Earth Ground 13

14 13. TERMINATION RESISTORS 14 Definition (Serial communication RS422/RS485) To make communication impedance equal with termination of communication line use 120Ω Purpose To prevent the reflection of electric signal at the end of communication line To decrease SNR ( Signal to Noise Rate) NOTICE RS422 : connect 120Ω at the both ends of / and / RS485 : connect 120Ω at the both ends of RS485 A(T)/ RS485 B(T) 120Ω RS422 / RS232 Converter 120Ω Last Controller NOISE Reduction SIGNAL Reduction RS422 RS422 Termination Resistors SIGNAL NOISE SIGNAL + NOISE SIGNAL + NOISE (Without Termination Resistors) (With Termination Resistors) 14

15 14. COMMUNICATION ID SETTING Communication ID To identify each device in network and perform the communication between SW and devices Each device must have different communication ID in one loop 1 ) FINGER007/ 505R/ FINGER006 (LCD & KEYPAD) FINGER007 [F1] 08/28 12:30:30 Master ID + Password <MASTER MODE> Select Menu COMM ADDRESS ) FGR006/iCON100/iTDC/ FGR007 (DIP Switch) itdc 15

16 15. COMMUNICATION ID SETTING Dip Switch Setting Table Communication ID DOWNLOAD 1 Dip Switch NO. Dip Switch NO

17 17 For more information, Thank you. 17

Concept of Serial Communication

Concept of Serial Communication Concept of Serial Communication Agenda Serial v.s. Parallel Simplex, Half Duplex, Full Duplex Communication RS-485 Advantage over RS-232 Serial v.s. Parallel Application: How to Measure the temperature

More information

The I-2532 CAN to Fiber Converter

The I-2532 CAN to Fiber Converter The I-2532 CAN to Fiber Converter User s Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year from the date of delivery to the

More information

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics Communication accessories Selection guide There are 2 types of Sepam communication accessories: b communication interfaces, which are essential for connecting Sepam to the communication network b converters

More information

WARNING Improper operation may result in serious personal injury CAUTION

WARNING Improper operation may result in serious personal injury CAUTION SAFETY PRECAUTIONS Thank you for using our S100 Profibus-DP Communication module Safety PRECAUTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. Safety precautions

More information

Thank you for purchasing S100 Profibus-DP Communication Module SAFETY PRECAUTIONS

Thank you for purchasing S100 Profibus-DP Communication Module SAFETY PRECAUTIONS Thank you for purchasing S100 Profibus-DP Communication Module SAFETY PRECAUTIONS SAFETY PRECAUTIONS To prevent injury and danger in advance for safe and correct use of the product, be sure to follow the

More information

M-Bus Master MultiPort 250L Installation and User Guide

M-Bus Master MultiPort 250L Installation and User Guide Installation and User Guide Kamstrup A/S Industrivej 28, Stilling DK-8660 Skanderborg T: +45 89 93 10 00 info@kamstrup.com kamstrup.com Contents 1 Introduction 3 1.1 Design 3 2 Functionality 4 2.1 Overview

More information

I-2533CS series User Manual

I-2533CS series User Manual I-2533CS series User Manual Version 1.0.0, Sep. 2013 Service and usage information for I 2533CS / I 2533CS 60 / I 2533CS A / I 2533CS B I-2533CS series CAN to Single Mode Fiber Bridge User Manual (version

More information

MULTI-TOWER INTERCONNECTION - MANUAL /PLC CONTROL

MULTI-TOWER INTERCONNECTION - MANUAL /PLC CONTROL 8 MULTITOWER INTERCONNECTION The control master box for manual/plc control of multitower machines is an electronic device needed when the following control types are required: A. Manual control through

More information

LAN/Length Cable Tester TCT-2690 Pro

LAN/Length Cable Tester TCT-2690 Pro User Manual LAN/Length Cable Tester TCT-2690 Pro Introduction 2 Features 2 Specifications 3 Instructions for Operation 4 LAN Mode 4 Memory Mode 7 Low Battery Mode 8 TEL Mode 8 COAX Mode 10 TONE Mode 11

More information

RFID. LF Training. Installation and Set-up. J.A.G 7 March, 2008 Texas Instruments Proprietary Information 1

RFID. LF Training. Installation and Set-up. J.A.G 7 March, 2008 Texas Instruments Proprietary Information 1 RFID LF Training Installation and Set-up J.A.G 7 March, 2008 Texas Instruments Proprietary Information 1 S2000 Readers Radio Frequency Module (RFM) Control Module (CTL) Series 2000 Reader 3/28/2008 TI

More information

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A. Tel: <<<

RS232 to RS485 or RS422 line converter with isolation. >>> Distribucion: ER-Soft, S.A.  Tel: <<< RS232 RS485/422 RS232 to RS485 or RS422 line converter with isolation >>> Distribucion: ER-Soft, S.A. www.er-soft.com info@er-soft.com Tel: +34 916-408-408

More information

There are many important factors when trying to achieve good, reliable communications between 2 devices.

There are many important factors when trying to achieve good, reliable communications between 2 devices. APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data

More information

Copper Cords. Clarity Patch Cords. Clarity Shielded Patch Cords. Clarity 110 Patch Cords. Custom Assemblies

Copper Cords. Clarity Patch Cords. Clarity Shielded Patch Cords. Clarity 110 Patch Cords. Custom Assemblies HIGH PERFORMANCE STRUCTURED CABLING PRODUCTS AND SOLUTIONS Copper Cords Clarity Clarity 10G, Clarity 6 and Clarity 5E patch cords lead the impressive family of Ortronics cable assemblies. Patch cords are

More information

Load Cell Accessories and Services

Load Cell Accessories and Services Load Cell Accessories and Services Highlights Strain gage signal conditioners Cable assemblies Mounting accessories Calibration services PCB Piezotronics, Inc. Toll-Free in USA 888-684-0004 716-684-0001

More information

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 NS500 JUSP-NS500 SERVOPACK. 200V Ver.

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 NS500 JUSP-NS500 SERVOPACK. 200V Ver. JUSP- unit connectivity with positioning functionality. Connects directly to the drive Simplifies distributed control and information management No programming languages are required. Various positioning

More information

Network Cables 12. Flat Ribbon Cables 13. Coaxial Cables 14. Test Cables 15. Video Interconnect Cables 16. D-Sub Cables 17

Network Cables 12. Flat Ribbon Cables 13. Coaxial Cables 14. Test Cables 15. Video Interconnect Cables 16. D-Sub Cables 17 Cable Assemblies Network Cables 2 Flat Ribbon Cables 3 Coaxial Cables 4 Test Cables 5 Video Interconnect Cables 6 D-Sub Cables 7 Circular Connector Assemblies 8 System Tails 9 Cable Looms 20 Specialized

More information

Understanding and Inspecting THE DIGITAL BUS. by Jim Sparks

Understanding and Inspecting THE DIGITAL BUS. by Jim Sparks Understanding and Inspecting THE DIGITAL BUS by Jim Sparks 1 Means of Avionics Communication Analog Uses variable signals Voltage Amperage Frequency Discrete Changes a signal state Hi or Lo 1 or 0 On or

More information

Transmission Media. - Bounded/Guided Media - Uubounded/Unguided Media. Bounded Media

Transmission Media. - Bounded/Guided Media - Uubounded/Unguided Media. Bounded Media Transmission Media The means through which data is transformed from one place to another is called transmission or communication media. There are two categories of transmission media used in computer communications.

More information

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual

RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245. Operation manual RS 485/422 to Fibre Optic Modems ELO E243, ELO E244, ELO E245 Operation manual 1.0 Introduction 3 2.0 Operation principles 3 3.0 Installation 3 3.1 RS422 Interface Connection 4 3.2 RS485 Interface Connection

More information

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN

EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN EFFECT OF SHIELDING ON CABLE RF INGRESS MEASUREMENTS LARRY COHEN OVERVIEW Purpose: Examine the common-mode and differential RF ingress levels of 4-pair UTP, F/UTP, and F/FTP cables at an (RJ45) MDI port

More information

Blue Point Engineering

Blue Point Engineering DMX Data Analyzer Board nstruction Overview DMX Analyzer - Tester PC Board Design your own enclosure with an analyzer / tester display or add to your existing equipment or system. The DMX Analyzer is a

More information

Dielectric Material. Cable Type

Dielectric Material. Cable Type UTP Video Cables West Penn Wire/CDT introduces its new line of UTP security cables,v/cat. The V/CAT ( Video over Category 5E) is designed for the video over UTP applications. The cables are constructed

More information

SFP- GE- RJ45- AO. 1.25Gbps SFP Copper Transceiver

SFP- GE- RJ45- AO. 1.25Gbps SFP Copper Transceiver SFP- GE- RJ45- AO ZTE 1000BASE- TX SFP COPPER 100M REACH RJ- 45 SFP- GE- RJ45- AO 1.25Gbps SFP Copper Transceiver Features Up to 1.25Gb/s bi- directional data links Hot- pluggable SFP footprint Extended

More information

NETWORK CONNECTIVITY SYSTEMS

NETWORK CONNECTIVITY SYSTEMS NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation

More information

VBRC 4. Radio Communicator. Installer Manual

VBRC 4. Radio Communicator. Installer Manual VBRC 4 Radio Communicator Installer Manual 17 December 2014 CONTENT 1. INTRODUCTION...3 2. SYSTEM STRUCTURE...3 3. SYSTEM PROGRAMMING WITH PC SOFTWARE...5 4. TROUBLESHOOTING...6 5. FIRMWARE UPGRADE...7

More information

Analog Module D1-15P User Manual

Analog Module D1-15P User Manual D1-15P Manual Analog Module D1-15P User Manual Sielco Elettronica Srl Edison Street 209 20019 Settimo Milanese (MI) - Italy http://www.sielcoelettronica.com info @ sielcoelettronica.com Tel 02 48916252

More information

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937 Effective: June, 2000 LevelPRO Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937 The information contained in this manual was accurate at the time of release. Specifications

More information

Model NV-EC1701U Eo2 TM Ethernet over 2-Wire Transceiver with PoE, PoE+, or High Power PoE

Model NV-EC1701U Eo2 TM Ethernet over 2-Wire Transceiver with PoE, PoE+, or High Power PoE U Eo2 TM Ethernet over 2-Wire Transceiver Features: Transmit 10/100 BaseT Full Duplex Ethernet up to 1,000ft (305m)* over 4-pair cat5; 750ft (228m) over 18/2 (or similar 2-wire cable); 500ft (150m) over

More information

Hardware Manual. PCD3.F240/PCD2.F2400 LON interface module for TP/FT-10 channel. Hardware Manual PCD3.F240/PCD2.F2400, LON interface module

Hardware Manual. PCD3.F240/PCD2.F2400 LON interface module for TP/FT-10 channel. Hardware Manual PCD3.F240/PCD2.F2400, LON interface module Hardware Manual PCD3.F240 PCD2.F2400 PCD3.F240/PCD2.F2400 for TP/FT-10 channel Saia-Burgess Controls AG, 3280 Murten Page 1/12 0.1 Document history... 3 0.2 Trademarks... 3 1 F240/F2400... 4 1.1 Module

More information

Citilog XCOM-TS2 and XCOM-TS2-EXT. Interface Boards for Citilog XCAM-P specifications

Citilog XCOM-TS2 and XCOM-TS2-EXT. Interface Boards for Citilog XCAM-P specifications Citilog XCOM-TS2 and XCOM-TS2-EXT Interface Boards for Citilog XCAM-P specifications 1.1. FUNCTIONALITIES The XCom-TS2 allows: interfacing up to 6 XCam s to a traffic controller 3 connection options to

More information

Series SPPM2 Graphical User Interface Panel Meter. Specifications - Installation and Operating Instructions MINI USB PORT

Series SPPM2 Graphical User Interface Panel Meter. Specifications - Installation and Operating Instructions MINI USB PORT Series SPPM Graphical User Interface Panel Meter Bulletin PCSPPM Specifications Installation and Operating Instructions / [9.0] 9/ [9.] / [9.9] / [.9] / [.] 9/ [9.] JTAG [FOR INTERNAL USE] ALARMS, SERIAL

More information

Side view View from below Rear view

Side view View from below Rear view Dimension diagrams All dimensions in mm Side view View from below Rear view Cut out: 138 +0,8 x 138 +0,8 mm Typical connection SPS SPS 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 DSUB-9 5 4 3 2 1 8 7 6 5 4

More information

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j.

ADA-1028L. User manual ADA-1028L. RS232 to Current Loop 2-wire CLO Converter. 1 io_ada-1028l_v.1.10_en. Copyright CEL-MAR sp.j. User manual ADA-1028L to Current Loop 2-wire Converter Copyright 2001-2017 CEL-MAR sp.j. 1 io_ada-1028l_v.1.10_en Contents 1. GENERAL INFORMATION... 3 1.1. WARRANTED INFORMATION... 3 1.2. GENERAL CONDITIONS

More information

Insulation Tester Manual

Insulation Tester Manual Insulation Tester Manual *******Insulation resistance tester dedicated to the measurement of water-cooled generator test, but also can be used for laboratory or field testing insulation testing to do.

More information

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface...

Contents. Instruction Leaflet IL E Effective March HMi VU Series Instruction Leaflet. Description... Page. Preface... Instruction Leaflet IL04801003E Effective March 2013 HMi VU Series Instruction Leaflet Contents Description... Page Preface... 1 Safety Precautions... 1 Installation... 3 Wiring... 4 asic Inspection...

More information

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i Data Sheet NV-ER1816 16-Port Ethernet Receiver 10/100/1000 10/100/1000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Join Main Auxiliary OUTPUTS: 56VDC 1AMP MAX. PER PORT, 4.5A MAX, TOTAL (no analog / no ethernet)

More information

INSTALLATION INSTRUCTIONS FOR THE CLIKCARD COMMERCIAL RECEIVER (NARROW BAND)

INSTALLATION INSTRUCTIONS FOR THE CLIKCARD COMMERCIAL RECEIVER (NARROW BAND) Doc. 6001200 Rev. B INSTALLATION INSTRUCTIONS FOR THE CLIKCARD COMMERCIAL RECEIVER (NARROW BAND) TABLE OF CONTENTS TABLE OF CONTENTS...1 INSTALLATION FOR INFINITY AND PROCARD...3 PULLING CABLE... 3 MOUNTING

More information

Wireless Data Gathering Panel MODEL TS0825

Wireless Data Gathering Panel MODEL TS0825 Wireless Data Gathering Panel MODEL TS0825 Wireless Data Gathering Panel: Model TS0825 INSTALLATION GUIDE The TS0825 Wireless Data Gathering Panel may be installed up to 1.5km from the Challenger panel

More information

QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h.

QuidoDuplex RS. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS June 2011 w w w. p a p o u c h. Set for bi-directional transmission of 4 or 8 two-state signals over RS485 or RS232 7. June 2011 w w w. p a p o u c h. c o m Q uidoduplex RS Datasheet Created: 3/16/2006 Last update: 6/7/2011 8:57 AM Number

More information

Contents. Software Requirements

Contents. Software Requirements CALIBRATION PROCEDURE NI PXIe-4154 This document contains information for calibrating the NI PXIe-4154 Battery Simulator. For more information about calibration, visit ni.com/calibration. Contents Software

More information

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter

ADA User manual ADA RS-232 to RS-485 / RS-422 Converter User manual RS- to RS- / RS- Converter Copyright 001-01 CEL-MAR sp.j. 1 io_ada-100_v._en Contents 1. GENERAL INFORMATION... 1.1. WARRANTED INFORMATION... 1.. GENERAL CONDITIONS FOR SAFE USE... 1.. CE LABEL...

More information

Transmission Medium/ Media

Transmission Medium/ Media Transmission Medium/ Media The successful transmission of data depends principally on two factors: the quality of the signal being transmitted and the characteristics of the transmission medium Transmission

More information

Call For Interest PoE- plus. Chris Di Minico MC Communications

Call For Interest PoE- plus. Chris Di Minico MC Communications Call For Interest PoE- plus Chris Di Minico MC Communications cdiminico@ieee.org 1 IEEE 802.3 CFI Powering Ethernet Devices Over Data Cabling IEEE 802.3af Web Cameras Ethernet Switch Data and Power Security

More information

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide

PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide PROMUX Distributed MODBUS I/O Modules Catalog and Design Guide 12/03/2012 V11.0 P.O.Box 164 Seven Hills 1730 NSW AUSTRALIA Tel: +61 2 96248376 Fax: +61 2 9620 8709 Email: proconel@proconel.com Web: www.proconel.com

More information

ProHelp Systems MIU 10X/98 WIRING / INSTALLATION INSTRUCTIONS

ProHelp Systems MIU 10X/98 WIRING / INSTALLATION INSTRUCTIONS ProHelp Systems MIU 10X/98 WIRING / INSTALLATI INSTRUCTIS 2 MIU-10X /5XS SETUP AND CFIGURATI MIU-10X Configuration and Diagnostics Screen Upon boot-up the MIU-10X first runs a self-diagnosis routine to

More information

Universal RS232/CMOS to RS422/RS485 Converter

Universal RS232/CMOS to RS422/RS485 Converter TOSHIBA INTERNATIONAL CORPORATION Universal RS232/CMOS to RS422/RS485 Converter Rev No.: 2 Page No.: 1 RS232/CMOS to RS422/RS485 Converter converts RS232/CMOS lines to balanced RS422 or RS485 signals.

More information

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved

A50/A51/A60. June 2008 (4th Edition) All Rights Reserved A50/A51/A60 June 2008 (4th Edition) All Rights Reserved Part I - A50/A51 RS-232 to RS-422/RS-485 Converter A50/A51 RS-232 to RS-422/RS-485 Bidirectional Converter Part II - A60 RS-232 Surge Protection

More information

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

Earth Leakage Monitoring System IsoBase IsoHub IsoOut 2014 11 21 Earth Leakage Monitoring System IsoBase IsoHub IsoOut User Manual Due to our policy of continual improvement, specifications may change without prior notice Page 2 (34) Contents Earth Leakage

More information

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i Data Sheet NV-ER1816 16-Port Ethernet Receiver 10/100/1000 10/100/1000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Join Main Auxiliary OUTPUTS: 56VDC 1AMP MAX. PER PORT, 4.5A MAX, TOTAL (no analog / no ethernet)

More information

Field Instrument Cable. Electrical Noise

Field Instrument Cable. Electrical Noise Field Instrument Cable Electrical Noise 1 Electrical Noise Instrument Cables are Susceptible to 4 Types of Noise: Static Magnetic Cross-Talk Common Mode 2 Static Noise Static Noise is caused by an electric

More information

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21 M12 A-coding Specifications IEC 60 352-4 Approval A-coding acc. to IEC 61 076-2-101 Circular Connectors Technical characteristics M12 A-coding Type M12 A-coded HARAX M12-L 5 poles HARAX M12 L shielded

More information

Micro Thermo Standard Wiring Guide

Micro Thermo Standard Wiring Guide M I C R O T H E R M O T E C H N O L O G I E S TM Micro Thermo Standard Wiring Guide Document No.70-PHW-1003-R1.0 MTA V7.0 No part of this publication may be reproduced, stored in a retrieval system, or

More information

Serial Communications RS232, RS485, RS422

Serial Communications RS232, RS485, RS422 Technical Brief AN236 Technical Brief AN236Rev A Serial Communications RS232, RS485, RS422 By John Sonnenberg S u m m a r y Electronic communications is all about interlinking circuits (processors or other

More information

INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1

INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA1 INSTRUCTION MANUAL IP REMOTE CONTROL SOFTWARE RS-BA FOREWORD Thank you for purchasing the RS-BA. The RS-BA is designed to remotely control an Icom radio through a network. This instruction manual contains

More information

Vibrating Wire Instrumentation

Vibrating Wire Instrumentation Vibrating Wire Instrumentation Design, Operations & Lines Test Results System Diagram - Fig 1 Sensor Excitation Circuit Differential Amplifier + + Sensor Coil - - High Pass 100 Hz Digital Filter Low Pass

More information

Ness M1RF Wireless Receiver

Ness M1RF Wireless Receiver INSTALLATION MANUAL Ness M1RF Wireless Receiver Specifications, Installation and Programming Page 1 (Version 1.4 - May 2008) Ness Document No. 895-364 APPLICATION The Ness M1RF Receiver is a unique high

More information

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1

AccessCON-N64 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL. Version 1 INTERFACE CONVERTER E1/FRACTIONAL E1 TO N64 INSTALLATION AND OPERATION MANUAL Version 1 Copyright 2005 by S-Access GmbH. The contents of this publication may not be reproduced in any part or as a whole,

More information

GT SERIES. QuikStart Installation Guide #95228

GT SERIES. QuikStart Installation Guide #95228 #95228 GT SERIES QuikStart Installation Guide ATTENTI: This is an abbreviated Installation Manual, addressing wiring and programming of the GT Series. The complete GT Series Installation Manual is located

More information

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 JUSP-NS500 NS500 SERVOPACK. 200V Ver.

Cable connection. Sigma-II series SERVOPACK SGDH- 200V. Ver. Servo Drive CN3 (CN10) CN1 CN2 JUSP-NS500 NS500 SERVOPACK. 200V Ver. JUS- unit connectivity with positioning functionality. Connects directly to the drive Simplifies distributed control and information management No programming languages are required. Various positioning

More information

Refer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both.

Refer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both. CERAVAC Transmitter CTR 100 N Short form manual 300544675_002_C0 Part numbers: 230 300V02 230 310V02 230 301V02 230 311V02 230 302V02 230 312V02 230 303V02 230 313V02 230 304V02 230 314V02 230 305V02 230

More information

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100D 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100D radio modem acts as a wireless serial cable replacement and

More information

JUMO Wtrans Receiver with Wireless Data Transmission

JUMO Wtrans Receiver with Wireless Data Transmission Data Sheet 902931 Page 1/10 JUMO Wtrans Receiver with Wireless Data Transmission k For measuring temperature, pressure, potentiometer, and voltage. k Interface RS485 with Modbus protocol k Wireless measured

More information

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes Data sheet 902931 Page 1/10 JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes For processing physical measurands of the JUMO Wtrans series RS485 interface with Modbus protocol

More information

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

RM24100A. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1. RM24100A 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE 802.15.4 compliant) Operating Manual English 1.03 Introduction The RM24100A radio modem acts as a wireless serial cable replacement and

More information

Servo Drive MINAS-A4N with Realtime Express (RTEX) Phone: Fax: Web:

Servo Drive MINAS-A4N with Realtime Express (RTEX) Phone: Fax: Web: Servo Drive MINAS-A4N with Realtime Express (RTEX) 200W 200V Overview Realtime Express (RTEX) Advanced Network to realize high-precise real-time performance for Servo Control Concept High Performance &

More information

Brushed DC Motor Control. Module with CAN (MDL-BDC24)

Brushed DC Motor Control. Module with CAN (MDL-BDC24) Stellaris Brushed DC Motor Control Module with CAN (MDL-BDC24) Ordering Information Product No. MDL-BDC24 RDK-BDC24 Description Stellaris Brushed DC Motor Control Module with CAN (MDL-BDC24) for Single-Unit

More information

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Port, RS485/RS422 Serial Module

OPERATING INSTRUCTIONS AND SPECIFICATIONS NI Port, RS485/RS422 Serial Module OPERATING INSTRUCTIONS AND SPECIFICATIONS NI 9871 4-Port, RS485/RS422 Serial Module This document describes how to use the National Instruments 9871 and includes specifications and pin assignments for

More information

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION Installation and Operation Manual MSI Multi-Sensor Interface Hub Interface Module for all Sensors Network and Wireless CAUTION This equipment complies with the limits for a Class B digital device, pursuant

More information

OPERATING MANUAL SERIES R B F 400 VAC BRUSHLESS RACK SYSTEM

OPERATING MANUAL SERIES R B F 400 VAC BRUSHLESS RACK SYSTEM OPERATING MANUAL SERIES R B F 400 VAC BRUSHLESS RACK SYSTEM Version 1.0 (European 1.0) This is a general manual describing a series of racks receiving Servo Amplifiers having output capability suitable

More information

4 Channel Security Hubs

4 Channel Security Hubs 4 Channel Security Hubs Operating Instructions KD-4PUV Four Channel Passive Transceiver KD-4AUVRX Four Channel Active Receiver KD-4AUVRX & KD-4PUV are multi-channel video hubs that allow for the transmission

More information

Single Channel Loop Detector

Single Channel Loop Detector Single Channel Loop Detector Model LD120T Series The LD120T is a series of single channel inductive loop detectors. The use of microprocessor and surface mount technology enables a large number of functions

More information

ISOLGUARD R. overview catalogue. insulation monitoring device. Insulation Monitoring Device

ISOLGUARD R. overview catalogue. insulation monitoring device. Insulation Monitoring Device overview catalogue Insulation Monitoring Device Hakel is a dynamic company which since foundation in 1994 has quickly developed in terms of turnover and the product assortment. This dynamism can also be

More information

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,

Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, HEIDENHAIN Working with the measured value display unit ND 261 Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, Page backward in 9 decades

More information

Series 2000 Reader System. Reader S251B RI-STU-251B. Reference Guide. April 2000 SCBU035

Series 2000 Reader System. Reader S251B RI-STU-251B. Reference Guide. April 2000 SCBU035 Series 2000 Reader System Reader S251B RI-STU-251B Reference Guide April 2000 SCBU035 Series 2000 Reader System Reader S251B RI-STU-251B Reference Guide Literature Number: SCBU035 April 2000 Contents Preface...

More information

Specifications / Installation

Specifications / Installation 1 Specifications XL6/XL6M/XL6e OCS Models HE-XL105 / HE-XL1M5 / HEXT350C115 / HEXT280C115 HE-XL1E5 / HEXT351C115 12 Digital DC Inputs / 12 Digital DC Outputs 2 Analog Inputs (High Resolution) / 2 Analog

More information

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical specifications - Installation rules - Electrical connections - Modbus connection rules - DIP-switches settings -

More information

1000BASE-T Copper SFP Transceiver

1000BASE-T Copper SFP Transceiver 1000BASE-T Copper SFP Transceiver Features: Operating data rate up to 1.25 Gbps Compact RJ-45 connector assembly Single 3.3V power supply and Low power dissipation Hot Pluggable 1000 BASE-T operation in

More information

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM Version 3.0 (European version 1.3) This is a general manual describing a series of racks receiving Servo Amplifiers having output capability suitable

More information

APPLICATION NOTE DA-100

APPLICATION NOTE DA-100 OZ OPTICS LTD. APPLICATION NOTE DA-100 OZ OPTICS FAMILY OF DIGITAL VARIABLE ATTENUATORS The information/data furnished in this document shall not be duplicated, used or disclosed in whole or in part for

More information

Battery Powered People Counter with Integral LCD Display & 418Mhz Data Transmitter

Battery Powered People Counter with Integral LCD Display & 418Mhz Data Transmitter Battery Powered People with Integral LCD Display & 418Mhz Data Transmitter The SenSource PCW-TB06 is a battery powered people counter with 418Mhz RF wireless data transmitter. Truly wireless installation

More information

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires.

A local 3.5 mm network jack allows a convenient way to connect an installation or diagnostic tool to the network without disconnecting any wires. FEATURES - Extends wiring distance of FTT-10 LonWorks Networks. - Up to 5 repeaters can be daisy chained together to create a multi-segment repeater of up to 10 channels. - Low cost alternative to routers

More information

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U:

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U: Application 4-9300 Specification Nov 06 Rev.C AMP Netconnect* Cat.6 Compact Patch Panel 0.5U, 4 Ports. SCOPE This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel

More information

Contents. Warranty and Disclaimer 2 Introduction 3

Contents. Warranty and Disclaimer 2 Introduction 3 Contents Warranty and Disclaimer 2 Introduction 3 Physical Dimensions Board Layout 4 Servo connections 5 Using the Serv8 Usage 6 Setting the start address 7 Setting the pulse width 8 Using the configuration

More information

Installation Manual ID ISCM01-A/B System delivery contents:

Installation Manual ID ISCM01-A/B System delivery contents: R O B I D i-scan Installation Manual ID ISCM01-A/B antenna test point 1 Cx 1 X2 X1 1 44,0 mm 50,0 mm X3 V100 green V101 red ø 3,3 mm 67,0 mm 75,0 mm System delivery contents: 1 x ID ISCM01-A/B M81191-5E-ID.doc

More information

Lecture #3 RS232 & 485 protocols

Lecture #3 RS232 & 485 protocols SPRING 2015 Integrated Technical Education Cluster At AlAmeeria E-626-A Data Communication and Industrial Networks (DC-IN) Lecture #3 RS232 & 485 protocols Instructor: Dr. Ahmad El-Banna 1 Agenda What

More information

Contents. Warranty and Disclaimer 2 Introduction 3

Contents. Warranty and Disclaimer 2 Introduction 3 Contents Warranty and Disclaimer 2 Introduction 3 Physical Dimensions Board Layout 4 Usage Using the Relay board 5 Setting the start address 5 Configuration Jumper 6 Using the Relays 7 Using the DMX connectors

More information

multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER

multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER Model : DI-6400 Your purchase of this INSULATION TESTER marks a step forward for you into

More information

SNR-SFP100-T. SNR-SFP100-T 10/100M Copper SFP Series

SNR-SFP100-T. SNR-SFP100-T 10/100M Copper SFP Series SNR-SFP100-T 10/100M Copper SFP Series 10/100BASE-T Copper SFP Transceiver RoHS6 Compliant Features Support 10/100BASE-T Operation in Host Systems For 100m Reach over Cat 5 UTP Cable Hot-Pluggable SFP

More information

Model NV-ET1804 TBus Four Port PoE+ Transmitter with Four PoE, PoE+, or High Power PoE Ports

Model NV-ET1804 TBus Four Port PoE+ Transmitter with Four PoE, PoE+, or High Power PoE Ports Features: Transmit 10/100/PoE+ BaseT, over Coax 8,000ft* over RG-59U; 2,000ft over 2-Wire/UTP; 1,300ft over Shielded Twisted-Pair* Use with either the NV-ER1804 (4-Port), the NV-ER1808i (8-Port) or the

More information

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER

INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER QUICK START GUIDE ICD201A INDUSTRIAL OPTO-ISOLATED RS-232 REPEATER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - What s Included ICD201A Industrial Opto-Isolated RS-232 to RS-422/485

More information

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU

New Product Bulletin. Belden Digital Audio Cable. Belden Brilliance AES/EBU New Product Bulletin NP 267 Belden Digital Audio Cable Belden Brilliance AES/EBU Digital Audio Cable, Part No. 1353A, is a robust single-pair Cat 5e patch cord that utilizes Belden s exclusive Bonded-Pair

More information

Atrie WireSpan 600/610 MODEM User's Manual

Atrie WireSpan 600/610 MODEM User's Manual Atrie WireSpan 600/610 MODEM User's Manual WireSpan 600 / 610 Fractional E1 Access Unit Installation and Operation manual CONTENTS CHAPTER 1 Interduction.. 1-1 CHAPTER 2 Installation and Setup.. 2-1 CHAPTER

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

User Manual EnOcean V 0.1

User Manual EnOcean V 0.1 & User Manual EnOcean V 0.1 Last update: July 2012 All software-related descriptions refer to the software V1279. We recommend to update older versions of the system. Small deviations in the description

More information

Single phase meter with direct connection and pulse or Modbus RS485 output

Single phase meter with direct connection and pulse or Modbus RS485 output 87045 LIMOGES Cedex Telephone: +33(0)5 55 06 87 87 Fax: +33(0)5 55 06 88 88 Single phase meter with direct connection CONTENTS PAGES 1. Description, usage... 1 2. Range... 1 3. Dimensions... 1 4. Positioning...

More information

G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis

G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis JUNE 1998 MT243A MT243C-F RM243A G.703 Balun Module Panel Unit G.703 Balun Module G.703 Balun Chassis CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S. 24 hours, 7 A.M. Monday to midnight Friday:

More information

Conectores Circulares 7/8

Conectores Circulares 7/8 Conectores Circulares 7/8 SUMinistros industriales MP4 S.L. TEL. +34 93 590 94 77 c/adrià Gual, 10 local 2 08173 Sant Cugat del Vallès Barcelona (Spain) www.suministros-industriales.es e-mail: mp4@suministros-industriales.es

More information

10 Amperes max. test current Micro-Ohm Meter Model : MO-2014 OPERATION MANUAL

10 Amperes max. test current Micro-Ohm Meter Model : MO-2014 OPERATION MANUAL 10 Amperes max. test current Micro-Ohm Meter Model : MO-2014 Your purchase of this Micro-Ohm METER marks a step forward for you into the field of p r e c i s i o n measurement. Although this Micro-Ohm

More information

8 Input/8 Output AC Block I/O Module

8 Input/8 Output AC Block I/O Module 8 Input/8 Output AC Module Installation Mount the block I/O module in a vertical (recommended) or horizontal position. Allow sufficient room around the block for cooling air flow through the block module.

More information

Radio Control Installation and Operating Instructions System 4

Radio Control Installation and Operating Instructions System 4 Radio Control Installation and Operating Instructions System 4 P.O. Box 403, One Cedar Parkway, Jackson, WI 53037 Phone: 800-628-1909 Fax: 262-677-2058 Revision: April 19, 2012 Contents Introduction 3

More information