UPS - modules serve for the buffering of a voltage for a certain period.
|
|
- Rosamond Cameron
- 6 years ago
- Views:
Transcription
1 DC-UPS 100 Module DC - UPS 100 BRIEF DESCRIPTION UPS - modules serve for the buffering of a voltage for a certain period. B The modules contain the following functional groups: Power Fail: At power failure a signal is given through an optocoupler (open collector) Deep discharge protection: If the voltage goes under a certain value, the battery will be separated from the electrical load. Reintercalation occurs if the input voltage exists again. Battery low: compendiously before the deep discharge protection switches, a signal is given about an optocoupler (open collector). Shut Down: The UPS can be switched off beyond an optocoupler. The re-start begins when the input voltage is o.k again. Triggering 10-28V. Auto Shut Down: At certain operating systems there is no shut down signal given. Here the auto shut down switches off the UPS independently after a time from up to 15 min. Load sensor: This sensor monitors the external power consumption and switches off the UPS while undercutting the opposed value at UPS operation. Acoustic signal: Additional to the LED advice an acoustic signal about a piezo can be given. Thereby occurs a sound in long distance with power fail and in short distance at battery low. Battery test: While the normal operation, the aditional battery will be controlled in regular intervals. When the battery is unloaded or defective then the announcement battery low is given. Battery loading unity: From the nominal input voltage the raised loading voltage is generated after the IU-identity line.
2 B TECHNICAL DATA Input voltage: 12V / 24V - 10% % Output voltage: Ue - 0,3V or rather at USV-operation U Bat -0,3V Temperature range: Standards Safety standard: Identification: C off 50 C 2,5% Derating / K EN60950, EN CE Mechanical Data Weight: Dimensions: Connection: ca. 210g L: 100mm B: 63mm H: 22,5mm Quick action plug General Data Air humidity: Timer option (shut down): Own consumption: Load sensor (Factory setting): Battery test: 0-95%, non condensated Time-steered shut down in USV operation available 0-15 min. standard 4sec. LED - status announcement Power o.k ->green/ USV-operation ->yellow/ Battery low -> red ca. 30mA at USV operation 200mA +/- 30% Time intervall 8 min ORDER NUMBER DC-USV/100 Version 12V/10A DC-USV/100 Version 24V/5A DC-USV/100/12 DC-USV/100/24 Wolfgang Bürger Hölzlestraße Reutlingen Telefon (07121) Telefax (07121) mailto@buerger-electronic.de Internet
3 DC-UPS Connection plan DC-UPS 100 DC-UPS Input Output 12/24V Fuse protection DC - UPS100 8A DC - UPS A 12V Battery 1 12V version 2 x 6V battery V Battery 2 Option: Key for starting the modul without input voltage. The load current will be assumed from the modul immediately. - + load Technical modifications and errors excepted Last change: Data name: DC_USV_1_Anschluss_eng.cdr
4 Configuration connection Load sensor Uht 10 Uht 10 LS 5 50k LS 5 GND 12 LS 5 GND 12 Factory setting ca ma => ca. 0,25V at pin 5 When the power rises on pin 5, so the shut-off barrier will increase. alternativ Note: Every UPS has a shut down blocker, which operates ca. 2 minutes (+/-20%) after switching on of the UPS. This also concerns the load sensor. The load sensor can only be shut down, when the adjusted current is undercutted and the time of the shut down barrier has drained. Auto Shut down Over temperaturemonitor or rather battery defect BUZ 11 Temp 8 ASD 6 GND 12 Opened => ASD inactiv Closed=> ASD activ LED shines at over temperature and defective battery Extern tricolor LED Alarm output LED-R 14 Uht 10 LED-G 13 + green red Piezo GND 12 BUZ 11 Intern LED shut down, or rather going darker Uo: ca. 3,3V I: ca. 5mA Timer Shut down Uht 10 Time 1 1MR => 15 min 100k => 1 min 15 sec 47k => 40 sec 10k => 8 sec 4,7k => 4 sec 1k => 1 sec OHM 1M 800k 600k 400k 200k UPS Timer - shut down timer Standard 4,7k below of LED free accessible Minutes Rmin: 1kR Rmax: 1MR Technical modifications and errors excepted. Last change: Data name: Konfigurations_Anschluss_1_eng.cdr
5 Plug connection signal part DC-UPS Resistor Shut down Timer Resistor Shut down Lock (* ca. 2min) Circuit board Plug LED 2 1 Plug Cooler * Note: The time of the shut down barrier can be reduced by reduction of the resistor. Plug 1: PIN Description Abbreviation 1 Timer Time 2 Shut down SD 3 Power fail PF 4 Signal ground Gnd A 5 Load sensor LS 6 Auto shut down ASD 7 Pull up voltage input U Temperature or rather battery Temp defective output 9 Batterie low BL 10 Auxiliary voltage * Uht 11 Buzzer connection BUZ 12 Ground Gnd 13 Connection LED green LED-G 14 Connection LED red LED-R * Note: Auxiliary voltage with 24V = 12V; with12v = 5V; it may can be load statically up to 10mA. Plug 2: PIN Description Abbreviation 1 Input voltage + Uin+ 2 Input voltage - GND 3 Output voltage + Uout+ 4 Output voltage - GND 5 Battery voltage + Ubat+ 6 Battery voltage - GND M:\WordDat\Produkte_BE\KFZ_USV\Steckerbelegung_Signalteil_eng.doc Last change:
6 Connector cable DC - UPS 100 Connector cable DC - UPS Type 1 UPS Side Ribbon cable Computer Side D - SUB 9 pole female NC NC NC 7 NC 1 Application: Direct connection to a computer with PC software RUPS 2000 or Windows 2000 professional Standard length 50cm Note: With Windows 2000 the disconnection occurs in the standard over the load sensor. The battery state is not supervised by the software. Connection cable variants: Type 1: Standard 50cm Type 2: Additional with auto shut down (ASD) and timer shut down resistor for 3 min. Type 3: Additional with monitor- LED in the plug Type 4: Additional with Buzzer for alarm in the plug Type 5: Special cables which exist of combinations of the standard types Last change: Data name: Anschlusskabel DCUSV100.cdr
7 Interface description Operating system: LINUX 7.1 UPS Software: RUPS 2000 V Interface description: The UPS will be connected to the COM-interface via server. After starting the RUPS-2000 software there are following levels at the interface: RTS + 11V from server, herewith will be the internal pull - up resistors pulled the signals power fail (CTS) and battery low (CD) to a positive level. With advice power fail or battery low, will the common tension - 11 V of the wire TXD of the server from the UPS on the particular signal wire be connected through. The software USV RUPS2000 releases then a controlled shut down of the server. Disconnection occurs over the load sensor. Note: The red RUPS 2000 cable is not used with DC-module USV, because the resistors are integrated. Interface: RS232 Input: RS232 Output: Power fail (CTS) Batterie low (CD) Shut down (DTR) is not supported by LINUX, -> necessary for Windows NT Common (TXD) Load sensor: Shut down at ca. 5W in standard Interface: UPS Connection: PIN CTS PF 3 Optocoupler for power fail RTS (+11V) U CD BL 9 TXD (-11V) GndA 4 DTR SD 2 Optocoupler for batterie low Optocoupler for shut down Intern circuit of DC-UPS Last change: Data name: Schnittstellenbeschreibung
8 Technical notes Shut down barrier The first 2 minutes is the shut down and auto shut down blocked. Reboot function When the shut down or auto shut down is released, then the time of the timer shut down the UPS. This also happens, if in the meantime the supply voltage is restored. In this case switches the UPS after approx. 2 sec. automatically on again. Timer shut down The standard module has in the standard a 4.7kR resistor. ( timer shut down= 4sec.) The resistor is freely accessible from the outside, below the LED, and must be changed for bigger times. Irrtum, Druckfehler und technische Änderungen vorbehalten Letzte Änderung: Dateiname: Technische_Hinweise.cdr
9 Development kit 2 H A + I E D G K B C F A) Load sensor Load sensor off ca.1a ca.1,7a ca.2,5a ca.4a Factory setting ca. 0,2A-0,25A B)Timer shut down Tolerance +/- 20% Intern shut down resistor 4 sec 8 sec 40 sec 1 min 15 sec 3 min 6 min For position 2-7 must be the resistor under the LED of the module removed. last change: Data name: Entwicklungskit_2_eng.cdr
10 Development kit 2 C) Auto Shut down: ASD on ASD off D) LED: lights at over temperatur or with defective or missing battery. Battery test: During the normal operation will be approx. every mins a battery test carried out. Missing or defective battery is indicated by the LED. The battery-defective-signal will be put back at mistake removal (after 10 min), or by a UPS case E) LED yellow: Power fail interface simulation LED red: Battery low interface simulation F) S hut down: interface simulation G) Intern RS232 simulation Extern RS232 connection H) Piezo acoustical alarm: At USP operation there will be given a slow alarm. This alarm gets faster at battery low. I) LED indication: Green = normal/ Yellow = USP/ Red = BL parallel connection to intern LED, thereby it is getting darker. K) Ribbon cable: Connection to DC-UPS module last change: Data name: Entwicklungskit_1.cdr
11 Simplified diagram DC-USP load piece Uin + Uin - Uout + Uout - load Charge controller U Bat + Control monitor signal unit U Bat last change: Data name: Prinzipschaltbild_DC-USV_eng.cdr
12 DC-UPS battery operation DC-UPS 100 DC-UPS 200 Fuse DC - UPS 100 8A DC - UPS A Input Output Signal plug LL4148 BC549 4,7k Battery Start button Pf of signal plug 100k This additional circuit prevent the restart, when the battery voltage recovers after shut down. 8A 12V battery V battery at 12V version 2 x 6V battery Option: Start button for starting the module without input voltage. Consumer The load current will be assumed immediately by the module. Last change: Data name: Batteriebetrieb_eng.cdr
13 DC-UPS EMC - Rules DC-UPS 100 DC-UPS Input Output DR1 12/24V DR2 Battery Battery load Note: 1. Cooler of the DC-UPS should be connected with GND, besides, no mass loops should arise.in the case of doubt put directly from the main plug a wire of minus on the case. 2. Inserting of choke in the input- and output plus wire Wire strenght Inductivity Current strenght Type 1,2 mm 2,2µH 10-15A choke 1,2 0,8 mm 4,8µH 5-7A choke 0,8 Last change: Data name: EMV_Regeln_eng.cdr
PowerPlex Compact Module PP-C-COM24
Description The PowerPlex Compact Module has been designed for the 12 V or 24 V DC-System of special vehicles, buses or boats. It provides inputs for switches and sensors as well as power outputs with
More informationElectronic Circuit Breaker with reset input ESS20-1..
Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and
More informationLogosol AC/DC Intelligent Servo Drive for Coordinated Control LS-174WP
Features Motors supported: - Panasonic A and S series - Brushless 60/120 commutated - Brush-commutated (DC) motors Up to 20A peak, 12A continuous output current 12 to 90VDC power supply Separate motor
More informationElectronic Circuit Breaker ESS20-0..
Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,
More informationIntegrated servo motor
R88E-AECT@, R88S-EAD@ Integrated servo motor Motor and drive integrated for space optimization Wide range of motors from 2.55 Nm to 25 Nm 3000 rpm rated speed Peak torque 300% of rated torque IP65 protection
More informationGSM/GPRS/GPS Tracker GV100. User Manual TRACGV100UM001. Revision: Quectel Wireless Solutions
GSM/GPRS/GPS Tracker GV100 User Manual TRACGV100UM001 Revision: 1.00 Quectel Wireless Solutions www.quectel.com Info@quectel.com Document Title GV100 User manual Version 1.00 Date 2009-10-15 Status Document
More informationPULSAR-EQUAL v 1.10 Art.No.: 1126
PULSAR-EQUAL v 1.10 Art.No.: 1126 10.12.2011 The Pulsar-EQUAL is a professionally designed and built, micro processor controlled balancer/equalizer and tester. The Pulsar-EQUAL is able to equalize the
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More informationSmart Power Relay E I...
Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SG Series 80 100 120 kva 400 Vac CE Series 0 Date of issue: 01.11.2007 SGSE_080_UPS_GE_01a SGSE_100-120_UPS_GE_01a
More informationPower Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250
Power Electronics POWERSWITCH Semiconductor Contactor, BH 9250 02342 According to IEC/E 60 947-4-2, IEC/E 60 947-4-3 1-, 2- and 3-pole models Load current up to 50 A For AC load up to 480 V Switching at
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationLow Profile. 3 Year Warranty
MCC Series 400 W Regulated Output Optional 200 W Non-regulated Conditioned Rail 1 to 4 Configurable Outputs MIL-STD-1275 and DEF-STAN 61-5 MIL-STD-461 and DEF-STAN 59-411 Low Profile Rugged Construction
More informationPreset counters, electronic
The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their
More informationmaxon document number:
maxon document number: 791272-04 1 Table of contents... 2 2 Table of figures... 3 3 Introduction... 4 4 How to use this guide... 4 5 Safety Instructions... 5 6 Performance Data... 6 6.1 Motor data... 6
More informationTECHNICAL DATA SHEET. Safety and function tester GLP1-g. Standard model GLP1-g ELECTRICAL SPECIFICATION
TECHNICAL DATA SHEET Safety and function tester GLP1-g Revision 2.7 / valid from July 2017 Standard model GLP1-g ELECTRICAL SPECIFICATION Supply voltage Mains frequency No load current consumption 110
More informationPOWER ANALYZER OPERATION MANUAL. Model : DW-6090A
POWER ANALYZER Model : DW-6090A Your purchase of this POWER ANALYZER marks a step forward for you into the field of precision measurement. Although this POWER ANALYZER is a complex and delicate instrument,
More informationAHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics
Dewpoint-guided Power Controller for Glass and Handrail Heaters Front view Characteristics Dew point-guided power controller for cost-optimized operation of glass and handrail heaters Digital display of
More informationTechnical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V
Technical Data Sheet Uninterruptible Power Supply On-line VH Series UPS 2000-3000 UL / 208V GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850
More informationPHOENIX CONTACT
Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode
More informationVARAN Stepper Module VST 012
VARAN Stepper Module VST 012 The VST 012 is a VARAN module designed for the control of a stepper motor up to a maximum 10 A RMS. The available operating modes are full step, half step and micro step. The
More informationIQ SENSOR NET MIQ/MC(-A)-RS
ESC OK! OK Operating Manual IQ SENSOR NET MIQ/MC(-A)-RS Power C M S Modem Radio Remote connection to the IQ SENSOR NET System 2020 XT via - fixed line telephone network - mobile network - radio link ba64121e03
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer IN 1000-S N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)
More informationConfirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED,
HEIDENHAIN Working with the measured value display unit ND 261 Confirm entry value Set display to value from Actual value and input display Select datum P79 (P80!) (7-segment LED, Page backward in 9 decades
More informationElectronic Circuit Breaker ESS1 for System SVS1
Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch
More information2304 EN. High-Precision Automatic Inspection and Test Unit for Electrical Resistance Testing RESISTOMAT. Automatic inspection and test unit
High-Precision Automatic Inspection and Test Unit for Electrical Resistance Testing RESISTOMAT Model 2304 Code: Delivery: Warranty: ex stock 24 months Automatic inspection and test unit Highest measuring
More informationJacket heater, etc Mounting bracket for Pipe wrapping. (Optional) Temperature sensor. Output (To heater) (Optional)
Temperature Controller with Built-in SSR SB SB General Description SB is a channel temperature controller with Built-in SSR (Solid state relay) designed for flexible heating solutions such as heat trace
More informationPulse Amplifier DIV 20 Instruction Manual 03/2016
Pulse Amplifier DIV 20 Instruction Manual 03/2016 QIOPTIQ Photonics GmbH & Co. KG Hans-Riedl-Str. 9 D-85622 Feldkirchen Germany Tel.: +49-89/255458 890 Fax: +49-89/255458 895 1. Safety remarks In order
More informationUniversal RS232/CMOS to RS422/RS485 Converter
TOSHIBA INTERNATIONAL CORPORATION Universal RS232/CMOS to RS422/RS485 Converter Rev No.: 2 Page No.: 1 RS232/CMOS to RS422/RS485 Converter converts RS232/CMOS lines to balanced RS422 or RS485 signals.
More informationInstallation- / Monitoring technique
Installation- / Monitoring technique ifferential current monitor IP 5883, Type B for AC and C systems varimeter 0249633 IP 5883 N 5018/035 N 5018/030 According to IEC/EN 62 020, VE 0663 To detect earth
More informationMI2500RU. Series. Compact, 1 x 1 Inch 25W, 4:1 Input Range DC/DC Con vert ers. Key Features: Electrical Specifications
MI2500RU Compact, 1 x 1 Inch 25W, 4:1 Input Range DC/DC Con vert ers Electrical Specifications Key Features: 25W Output Power 4:1 Input Voltage Range Compact 1 x 1 Inch Case 1,500 VDC Isolation 12 Standard
More informationTORKEL 900-series Battery Load Unit
Batteries can be tested in service Dynamic discharge technology full power at all voltages Safety in all details, e.g. detection of blocked airflow Real time monitoring during test Quick report Easily
More informationSelect datum Page backward in. parameter list
HEIDENHAIN Working with the measured value display unit ND Actual value and input display (7-segment LED, 9 decades and sign) Select datum Page backward in parameter list Confirm entry value Set display
More informationSPECIFICATION. Online UPS 3000VA
Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at
More informationTOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test
A new standard for Hipot & Insulation resistance testing Applied to World-Wide input voltage TOS5301 TOS5300 TOS5302 TOS5300(ACW) TOS5301(ACW/DCW) TOS5302(ACW/IR) New low-cost standard model that provides
More informationLogosol Intelligent Hall-Servo Drive LS-173U Doc # / Rev. C, 02/12/2008
Features Specially designed for control of brushless motors without encoder Hall-Servo and Encoder-Servo control modes Motors supported: - Brushless 60/120 commutated (AC) - Brush-commutated (DC) Up to
More informationFor the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.
Current Transducer IN 1000-S I P N = 1000 A For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Closed loop (compensated)
More informationMODEL 421 Over/Under Motor Load Monitor
MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart
More informationFor ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.
Current Transducer ITN 1000-S ULTRASTAB I PM = 1000 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)
More informationSimplified Operations for TM-3100 Series Digital Tachometer
Simplified Operations for TM-3100 Series Digital Tachometer The TM-3100 series Digital Tachometers has the most fundamental function in rotational measurement of four standard models (rotation speed display,
More informationInstallation / Monitoring Technique
Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and
More informationElectronic Circuit Protector ESX10-T
Electronic Circuit Protector ESX0-T Description Electronic circuit protector type ESX0-T is designed to ensure selective disconnection of systems. power supplies, which are widely used in industry today,
More information2601 System SourceMeter 2602 Multi-Channel I-V Test Solutions
601 System SourceMeter 60 Multi-Channel I-V Test Solutions SPECIFICATION CONDITIONS This document contains specifications and supplemental information for the Models 601 and 60. Specifications are the
More informationTORKEL 900-series Battery Load Unit
TORKEL 900-series Batteries can be tested in service Dynamic discharge technology full power at all voltages Safety in all details, e.g. detection of blocked airflow Real time monitoring during test Easy
More informationInstruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information
Instruction INFOCAL 8 Energy calculator 1.0 Table of contents 1.0 Table of contents...1 2.0 Safety notes and product information...1 3.0 Installation of energy calculator...2 4.0 Installation of temperature
More informationPARM-SIZED, 16-CHANNEL RELAY TERMINALS
Pressure connector connect type Wire-direct connect type PARM-SIZED, -CHANNEL RELAY TERMINALS FEATURES Compact, space-saving design: The Relay Terminal with I/O channels measures only (W) (D) (H) mm (W).
More informationGutor PxW AC UPS Designed for North American Market
Gutor PxW AC UPS Designed for North American Market PEW 5 200 kva single phase PDW 10 220 kva three phase Higher ratings upon request schneider-electric.com 2 schneider-electric.com schneider-electric.com
More informationSTEP-UPS/24DC/24DC/3. Uninterruptible power supply. Data sheet. 1 Description. Features
Uninterruptible power supply Data sheet 105623_en_00 PHOENIX CTACT 2013-06-07 1 Description Uninterruptible power supply units continue to deliver power even in the event of mains breakdowns or failures.
More informationModel Number Structure
Current Sensor CSM DS_E Solid-state, Plug-in Current Sensor Applicable to motor overcurrent protection and 3-phase AC current detection. Inverse-type, start-up lock type, and instantaneous type overcurrent
More informationBrunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2
Ultrasonic energy meter Type 775 Installation Guide Edition 1.2 UK-QB101575 / 29.05.2012 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing
More informationSHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual
SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable
More informationHigh-precision portable RESISTANCE METER
8 High-precision portable RESISTANCE METER measures from µω to MΩ Features High-precision specs in a portable package(high accuracy of 0.02% rdg.) Design is ideal for maintenance and testing/measurement
More informationModel FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter
Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------
More informationHow to Choose Power Supplies
How to Choose Power Supplies Overview C5 D-Style Software Which is Better, Linear or Switcher Supplies? Because servo motors are inductive, they may run highly dynamic motion profiles. As a result, their
More informationDC PV Arc fault detection Unit
DC PV Arc fault detection Unit Installation, usage and other information Author: Peter v. Galen, Product Manager Date: 15-09-2014 Revision: B 1. Introduction The National Electrical Code 2011 states arc-fault
More informationPower supply CP-E 48/5.0 Primary switch mode power supply Data sheet
2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated
More informationDECLARATION OF CONFORMITY
DECLARATION OF CONFORMITY Manufacturer's Name: Transmille Ltd. Manufacturer's Address: Unit 4, Select Business Centre Lodge Road Staplehurst TN12 0QW. United Kingdom. Declares, that the product Product
More informationDatasheet. Electronic Circuit Protection ESX10-T
Datasheet Electronic Circuit Protection ESX0-T selected in fixed values from 0.5 A...2 A. Failure and status indication are provided by a multicolour LED and an integral short-circuit-proof status output
More informationQBU series Pockels cell driver
rev 1.14 / 2017 04 14 QBU series Pockels cell driver User manual Warning! This equipment produces high voltages that can be very dangerous. Please read user manual before starting operations. Important
More informationMeter Bus Application ANALOG-BOARD Revision 5.1
Meter Bus Application ANALOG-BOARD Revision 5.1 November 1995 Revision 5.1 Dear Customer, Texas Instruments would like to thank you for your request for the ANALOG BOARD Revision 5.1 design kits. The following
More information21 VA (l max 20 5 ms) Connection Cable 1 m, 4 x 0.75 mm 2 Functional data Factory settings Variable Setting Torque Inhibiting torque
echnical data sheet GK4A- Communicative SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for building
More informationUser Manual CTP4/8/16
KMT - Kraus Messtechnik GmbH Gewerbering 9, D-83624 Otterfing, Germany, 08024-48737, Fax. 08024-5532 Home Page http://www.kmt-telemetry.com, Email: info@kmt-telemetry.com User Manual CTP4/8/16 4/8/16-channel
More informationDSSIU-6-1U-V. Features VOM:
Fully configurable dedicated 1U high 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers. Powers up to 6 x DS50 to DS2000 at the same time.
More information1 What s in the shipping package?
SST 900B 900 MHz RS 232/RS 485 Wireless Modem Quick Start Guide 1 What s in the shipping package? SST-900B Wireless Modem CA-0910 Quick Start CD 3dBi 900M Hz Antenna Guide 2 External switch introduction
More informationIndustrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America
World-Wide 3-phase Input Voltage Range (nom. 200 Vrms to 480 Vrms), PF > 0.94 High Power Density 16 W/in 3 94% Typical Efficiency Parallel Operation up to 16 Units (50.4 kw) Cold-Plate Cooling System -25
More informationMODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator 1/1 high resolution Easy adjustment: electronic limiter at the valve open & closed
More informationPower Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250
Power Electronics POWERSWITCH Solid-State Contactor, BH 9250 02342 According to IEC/E 60 947-4-2, IEC/E 60 947-4-3 1-, 2- and 3-pole models Load current up to 50 A For AC load up to 480 V Switching at
More informationPower supply CP-E 12/10.0 Primary switch mode power supply Data sheet
2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer
More informationMS2109A AC/DC Clamp Meter. User Manual. Contents
MS2109A AC/DC Clamp Meter User Manual Contents 1. Safety information 1 1.1 Preparation 1 1.2 Usage 1 1.3 Signs and Labels 2 1.4 Maintenance 2 2. Description 2 2.1 Part name 3 2.2 Switch and button description
More informationmaxon motor maxon motor control 4-Q-EC Servoamplifier DES 70/10 Order number
control 4-Q-EC Servoamplifier DES 70/10 Order number 228597 April 2006 Edition The DES (Digital EC Servoamplifier) is a very efficient digital servoamplifier with sinusoidal current commutation for perfectly
More informationHITEK POWER XR KW X-RAY POWER SUPPLY MODULE
HITEK POWER XR1000 1 KW X-RAY POWER SUPPLY MODULE Component power supply for industrial x-ray systems, elemental analysis equipment, x-ray diffraction spectrometers, and materials process monitoring applications
More informationTechnical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity
KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator
More informationR&D TECHNICAL SPECIFI
INTRODUCTION Present document defines technical specs of a three phase UPS covering the power range from 20 to 30 kva ON-LINE DOUBLE CONVERSION Uninterruptible Power Supply Systems with forced ventilation
More informationCROSS Chassis from 160 A to 450 A
CROSS Chassis from 160 A to 450 A STS CATALOGUE Important note! The technical data enclosed is for general information. Please note that the operating instructions and references indicated on the products
More informationUniversal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485
4WSD9R0712-1/4 Model 4WSD9R Universal Converter Covers All the Bases- RS-232 to 4-wire RS-422, 2-wire or 4-wire RS-485 The 4WSD9R Universal Converter is a port-powered or externally powered two-channel
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationPeltier Cooled Thermal Management System User s Guide
Peltier Cooled Thermal Management System User s Guide For use with StellaCam II, StellaCam3 and Wat-120N astro-video cameras Developed and maintained by CosmoLogic Systems, Inc. Thank you for purchasing
More informationAC MASTER Switch mode sine wave inverter
USERS MANUAL / GEBRUIKERSHANDLEIDING / BETRIEBSANLEITING MANUEL D UTILISATION / MANUAL DE UTILIZACION / INSTRUZIONI PER L USO AC MASTER Switch mode sine wave inverter Models 12/200, 12/350, 24/200 & 24/350-230V
More informationControl solutions Biofloor
MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital
More informationMODEL: MRP6. Final Control Elements
Final Control Elements MINI-TOP ELECTRONIC ACTUATOR (rotary type) Functions & Features Small-size control valve actuator Electrical positioner incorporated 1/1000 high resolution Easy adjustment: electronic
More informationUser s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. SHI 400 / SHI 600 / SHI 1000 Pure Sine Wave Inverter The information presented in this document does not form
More informationJUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes
Data sheet 902931 Page 1/10 JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes For processing physical measurands of the JUMO Wtrans series RS485 interface with Modbus protocol
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...
Electronics & Software ICAM Type 5073A... Industrial Charge Amplifier for Applications in Manufacturing The ICAM charge amplifier (Industrial Charge Amplifier Manufacturing) converts the piezoelectric
More information02/11/2015
Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.
More informationFeatures : 15V 50A 0 ~ 50A. 750W 150mVp-p. 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.
SPECIFICATION MODEL OUTPUT INPUT PROTECTION FUNCTION ENVIRONMENT SAFETY EMC (Note ) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED WER RIPPLE NOISE (max.) Note. 0mVp-p VOLTAGE ADJ. RANGE VOLTAGE
More informationDSSIU-6-1U. Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers.
DSSIU-6-1U Dedicated 6-channel system interface unit for ultra-stable, high precision fluxgate technology DS series current transducers. Powers up to 6 x DS50 to DS2000 at the same time. Supports calibration
More informationTRC ELECTRONICS, INC AC/DC Power Supply Built-In Fan PFC 3000W MEAN WELL RSP-3000 Series
Bauart gepruft Sicherheit egelma ge od o s be wac g www. tuv.com ID 2000000000 TRC ELECTRONICS, INC. SPECIFICATION MODEL OUTPUT INPUT PROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE RSP-3000-2
More informationPRECISION CURRENT TRANSDUCERS. DC Current Transducers CT-100 CT-150. User s Manual. All Rights Reserved CAEN ELS d.o.o. Rev. 1.
< DC Current Transducers CT-100 CT-150 User s Manual PRECISION CURRENT TRANSDUCERS All Rights Reserved CAEN ELS d.o.o. Rev. 1.1 November 2014 CAEN ELS d.o.o. Kraška ulica, 2 6210 Sežana Slovenija Mail:
More informationTap Changer Analyzer & Winding Ohmmeter RMO60TD
Tap Changer Analyzer & Winding Ohmmeter RMO60TD Test current 5 ma 60 A DC Rapid automatic demagnetization AC Current monitoring channel Lightweight 13 kg Measuring range 0,1-2 k Two voltage sense channels
More informationHL 675 Data / Impulse Transmitter set User Manual
HL 675 Data / Impulse Transmitter set User Manual Version 02/2015 TAGHeuer Timin Page 1 / 8 1. Global The Set HL 675 is ideal for transferring Timing Data and Impulses. Its 500mW emitting power and its
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BATTERY IMPEDANCE METER BT4560 Component measuring instruments Determine Li-ion
More informationProcess Calibrator. TechChek 820
Process Calibrator TechChek 80 CONTENTS GENERAL... TURN ON... CONNECTIONS... TILT STAND...4 CHANGING BATTERIES...4 RESTORING DEFAULT SETTINGS... CONFIGURING TEMPERATURE SCALES... ENABLING AUTO-OFF... SELECTING
More informationSET Installation and Operating Instructions. Level switch for two sensors
Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 20.2.2013 Internet: www.labkotec.fi 1/14 SET-2000 Level switch for two sensors Copyright 2013 Labkotec
More informationKanAtoN 1 / 3 AIS Transponder. Installation Manual
Orolia S.A.S. Z.I. des Cinq Chemins 56520 GUIDEL - FRANCE Telephone: +33 (0)2 97 02 49 49 Fax: +33 (0)2 97 65 00 20 Web : http://www.mcmurdomarinesystems.com An Orolia Group Business DATE : 20/072012 KanAtoN
More informationRubidium Frequency Standard Model AR133A Ruggedized Low Profile
Ruggedized Low Profile Key Features Long-term-stability: 5E-11/month 2E-12 frequency accuracy & 100nSec 1PPS accuracy relative to 1PPS input when disciplined Short term stability: 5E-12 @ 100s Phase noise:
More informationmaxon motor maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers , , , ,
maxon motor control 1-Q-EC Amplifier DEC 24/1 Order numbers 249630, 249631, 249632, 318305, 381510 September 2009 edition The DEC (Digital EC Controller) is a 1-quadrant amplifier for controlling electronically
More informationTechnical Specification
LARGEST RANGE OF IMPULSE TESTERS UP TO 100KV/100KA Technical Specification E-MIG1203CWG revised: 22. June 2003 1 MIG Tester Type MIG1203CWG 1 MIG Tester Type MIG1203CWG 1 1.1 Introduction 1 2 General 2
More informationFlow sensor HVAC 100 (548000) Instruction for use. Imprint: Copyright all rights reserved Version Subject to modifications
Flow sensor HVAC 100 (548000) Instruction for use Imprint: Copyright 2017 - all rights reserved Version 547996.02 Subject to modifications Important Information These instructions for use must be read
More informationHigh-precision process calibrator Model CED7000
Calibration technology High-precision process calibrator Model CED7000 WIKA data sheet CT 85.51 Applications Research and development laboratories Calibration service companies and service industry Industry
More information