PF Correction Techniques in highly varying load
|
|
- Ernest Lewis
- 5 years ago
- Views:
Transcription
1 PF Correction Techniques in highly varying load Atul Tare Contents Issues faced in Industries Impact of varying loads on PF - various applications Impact of method of capacitor switching on Harmonics Impact of varying loads on DG sets Regulatory Initiatives Criteria for appropriate PF Improvement mechanism Solution you need
2 Issues Faced in Industries Modernization of Industries Shift to Electronic Controls Almost all loads (which were hitherto linear) became non linear To maximize PF incentives, source side PF improvement is attempted through Fixed capacitors or through APFC or slow response Thyristorized systems. Issues Faced in Industries While this helps maximize PF Incentive, PF under low load, fast changing loads, unbalanced loads is found either low lagging or leading. Improper method of capacitor switching is seen to generate Harmonics. Unbalanced loading conditions are prevailing in the industry.
3 Issues Faced in Industries Equally distributed single phase loads across three phases are not necessarily a balanced load. When one single phase load trips, the load becomes unbalanced, calling for Unbalanced PF compensation. Impact of varying loads on PF - various applications
4
5
6
7
8
9 Aluminum Rolling Mill application Drive application
10 Furnace application Mining application
11 CT Scan application
12
13 Unbalanced PF across phases Impact of varying load on PF
14 Impact of varying load on PF Resulting PF dropping to 0.01 lag momentarily When load changes kvar does not change adequately APFC not solution to all loads The load is changing ultra fast and is unbalanced across phases. For the same load levels, the PF profile of individual phases remain unchanged ( with and without APFC) though the load is unbalanced. Average PF is leading with APFC
15 Other Applications High Rise Buildings where many lifts can operate at a time. Furnace Loads Industries where Heavy Motors are switched on simultaneously Industries experiencing Voltage Flickering Problem.
16 Effect of Capacitor switching method on harmonics Without capacitor With capacitor Impact of wrong compensation on harmonics 13.8% THD I step 1 APFC Switched on 14.8% THD I step % THD I step % THD I step % THD I With every step of APFC, PF improves and THD I increases. % THD I increased from 13.8% to 22% on application of 200 kvar Balanced APFC.
17 Impact of wrong compensation on harmonics APFC Switched on 5.12% THD V step % THD V step 2 step % THD V 6.24% THD V step % THD V With every step of APFC, PF improves and THD V also increases. % THD V increased from 5.12% to 6.28 % on application of 200 kvar Balanced APFC. Effects of Harmonics High harmonics results in: - Cable overheating in undersized cables - Cable line loss in oversized cables - Nuisance tripping of Breakers - Resonance blow up of Capacitors. - Damage to Power Transformer - Malfunctioning of Electronic Controls and devices
18 SOURCE AND LOAD SHOULD WORK IN HARMONY. Load EB/DG EB/DG Load.POWER QUALITY ASSESSMENT AND CORRECTION ENSURES THIS OBJECTIVE. Impacts of varying load on DG sets DG Sets are the most vulnerable to varying loads: - Oversized or undersized DG resulting in high fuel consumption or DG not taking load. - Production loss when DG not taking load - Increased inventory to cope up with power cuts - Poor Quality of products especially welding components - increased rejection - Poor Power Factor
19 Regulatory Initiatives Encourage customers to maintain a flat load profile. Bill customers on kvahr instead of kwhr. PF incentive is withdrawn. Consumers above 500 kva contract demand will have to declare Harmonic Levels and their plans to mitigate them. (Position varies from State to State). Criteria - Appropriate PF Improvement solution Rate of Change of Load Capacitor Switching Technique Type of load Balanced or Unbalanced Source Independency DG Compatibility Harmonic Mitigation
20 What do you need? The Solution should provide - Cycle to Cycle Compensation In 20 milliseconds - Transient free switching - Curtailing harmonics to desired levels - Compatible to run on both DG and EB supply - Maintain Unity Power Factor under Unbalanced loading conditions Cummins can help you with a System having features Cycle-by-cycle reactive power compensation providing mirror image compensation Transient-Free Solid-state Capacitors Switching Energy Savings Compatible to both EB and DG Enhancement of generation capacity (DG Sets) Harmonic Filtration Prevention of Voltage drops, Reduction of Voltage Flickering Comprehensive Power Quality Analyzer Self testing and comprehensive reporting feature
21 Thank You Contact Us: Atul Tare Power Electronics Cummins India Ltd Mob:
Thyristorised Automatic Power Factor
Thyristorised Automatic Power Factor Correction with 7% D Tune Harmonics Suppression (Reactor/Filtering) System Power quality? In the present Low voltage (LV) industrial distribution system the power factor
More informationP2 Power Solutions Pvt. Ltd.
P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Active Current Conditioners P2 Power Solutions Pvt. Ltd. P2 Power Solutions works to deliver Innovative Engineering solutions with specific focus on
More informationActive Harmonic Filter (AF3)
Active Harmonic Filter (AF3) Active Harmonic Filter Improving the Efficiency and Life of System by use of Digital Active Power Conditioner HARMONICS 50 Hz, fundamental 100 Hz, 2nd Harmonic 150 Hz, 3rd
More informationARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services
ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services edarat group INTRODUCTION Harmonics are a mathematical way of describing distortion
More informationActive Harmonic Filters IPC150 AHF Series
IPC150 AHF Series Multi Function Ultra Fast Power Quality Compensation Harmonics Power Factor Correction Unbalance Compensation www.inphase.in ISO 9001:2008 Certified THE CHALLENGE To increase the productivity,
More informationCASE STUDY. Implementation of Active Harmonic Filters at Ford Motor Company SA Silverton Plant
CASE STUDY Implementation of Ford Motor Company SA Silverton Plant 1 SCENARIO Ford Motor Company is a global automotive and mobility company based in Dearborn, Michigan. Ford Motor Company of Southern
More informationHARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N
HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N Harmonic Basics 3 rd Harmonic Fundamental 5 t1h Harmonic 7 th Harmonic Harmonic
More informationP2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company
P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Quality Power within your Reach P2 Power Magnetics P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. provides EMC and power quality solutions,
More informationWorld Academy of Science, Engineering and Technology International Journal of Electrical and Computer Engineering Vol:7, No:6, 2013
Investigating the Effect of Using Capacitorsin the Pumping Station on the Harmonic Contents (Case Study: Kafr El-Shikh Governorate, Egypt) Khaled M. Fetyan Abstract Power Factor (PF) is one of the most
More informationCHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS
86 CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS 5.1 POWER QUALITY IMPROVEMENT This chapter deals with the harmonic elimination in Power System by adopting various methods. Due to the
More informationAGN 026 Harmonic Voltage Distortion
Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 026 Harmonic Voltage Distortion Comment; The critical level of acceptable harmonic voltage distortion % is set
More informationPower factor correction and harmonic filtering. Automatic power factor regulators R.1
Power factor correction and harmonic filtering Automatic power factor regulators R.1 R.1 Automatic power factor regulators R.1 - Automatic power factor regulators Selection table R1-4 computer Plus-T Intelligent
More informationPower Analysis Summary
Power Analysis Summary Introduction This is a summary of the power conditions measured with these setup parameters: Measurement File: C:\Users\fhealy\Documents\Fluke\Power Analyze\Core 2 Recording.odn
More informationHarmonics, its Mitigation & Result of Case study of Spinning Mill
International Journal of Innovative Research in Engineering & Management (IJIREM) ISSN: 2350-0557, Volume-2, Issue-4, July 2015, its Mitigation & of Case of Spinning Mill Yogesh Subhash Shimpi M. Tech
More informationPRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.
1 PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS. DEFINATIONS Working /Active Power: Normally measured in kilowatts (kw). It does the "work" for the system--providing the motion, torque,
More informationPower factor correction and harmonic filtering. Automatic power factor regulators
Power factor correction and harmonic filtering Automatic power factor regulators Automatic power factor reguladors R.1 - Automatic power factor regulators Selection table R1-4 computer Plus-T Intelligent
More informationAdvantages There are many diverse advantages of a portable analyzer for the user. The most important is information.
Portable s CIRCUTOR offers a wide range of portable analyzers designed to measure, display and/or record the most important parameters of an electrical network. With the analysis of the electrical parameters,
More informationReal Time Power Factor Correction Units (Transient Free Switching)
Real Time Power Factor Correction Units (Transient Free Switching) Designers and Manufacturers of Power Factor Correction Equipment and Harmonic Filters 1016 34 AV SE Calgary, AB T2G 1V4 Canada Tel: 403
More informationUnderstanding Power Quality
Understanding Power Quality Produced by Dr Bruce Girdwood For Energy Mad Ltd Version 1: 23 October 2007 The electronics revolution and the growing number of utility programmes promoting compact fluorescent
More informationPQ Audit - The right choice to ensure power system performance. Mr Lalit Kumar Wasan Tata Power- DDL
PQ Audit - The right choice to ensure power system performance Mr Lalit Kumar Wasan Tata Power- DDL Outline vpower Quality v Present Challenges v Harmonics & Its Impact on DISCOM v Future Challenges Roof-Top
More informationTHE COMPREHENSIVE APPROACH TO FACILITY POWER QUALITY
by Cesar Chavez, Engineering Manager, Arteche / Inelap, and John Houdek, President, Allied Industrial Marketing, Inc. Abstract: Industrial facility harmonic distortion problems can surface in many different
More information3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.
MAIN TOPICS DISCUSSED Electric Rates Electrical system utilization ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K Power quality Harmonics Power factor (Cos phi) improvement Section K - 2 ELECTRIC
More informationPower Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss
Power Conditioning Equipment for Improvement of Power Quality in Distribution Systems M. Weinhold R. Zurowski T. Mangold L. Voss Siemens AG, EV NP3 P.O. Box 3220 91050 Erlangen, Germany e-mail: Michael.Weinhold@erls04.siemens.de
More informationA PQ Case Study CS 36 HOSP 14. A Case Study OF Harmonics Mitigation in a Hospital and its Benefits
CS 36 HOSP 14 36 Abstract A leading hospital in southern India faced chronic problems in terms of humming noise in capacitor bank, its failure, high temperature in transformer, and disturbances on the
More informationMcGill Power Sales & Engineering, INC.
1 McGill Power Sales & Engineering, INC. Power Factor Correction Terry McGill President McGill Power Sales & Engineering Inc. 2007 Eaton Corporation. All rights reserved. Agenda What is power factor? What
More informationTechnical News. Part 2: Harmonics. The link between harmonics and power factor. Industrial Electrical and Automation Products, Systems and Solutions
Issue #65 - December 2012 Technical News Industrial Electrical and Automation Products, Systems and Solutions Part 2: Harmonics The link between harmonics and power factor Written by Justin Charlot Product
More informationPower Quality Monitoring:
Power Quality Monitoring: Analyse and Improve your Energy Performance Presented by: David Bradley B.Eng (Hons), MBA, C.Eng, MIET Energy Management & Power Quality Key Drivers PART L The energy efficiency
More informationPeteris Spels, ABB Inc., WMEA, November 18, 2011 HARMONICS. ABB Group December 14, 2011 Slide 1
Peteris Spels, ABB Inc., WMEA, November 18, 2011 HARMONICS December 14, 2011 Slide 1 Agenda Harmonics: What they are? Where do they come from? Why bother? Regulations How to detect? How to avoid? Summary
More informationAutomatic capacitor banks with detuned filters
الکتروه م ند Power factor correction and harmonic filtering Automatic capacitor banks with detuned filters www.electrohamand.com Automatic capacitor banks with detuned filters Introduction R5/6-3 R.5 -
More informationAnalysis the Modeling and Control of Integrated STATCOM System to Improve Power System
Analysis the Modeling and Control of Integrated STATCOM System to Improve Power System Paramjit Singh 1, Rajesh Choudhary 2 1 M.Tech, Dept, Elect, Engg, EMax group of institute, Badauli (H.R.) 2 Astt.Prof.,
More informationEmicon Engineering Consultants L.L.C.
Emicon Engineering Consultants L.L.C. Power Quality Consulting & Solutions Presentation / Pre-Qualification Emicon, Specialised in Power Quality Consulting and Pollution Control on Electrical Network www.emiconconsultants.com
More informationLiebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM
Liebert AF2 Next Generation Active Harmonic Filter Power Protection for Business-Critical Continuity TM LIEBERT AF2 You Need To Be Aware Of Harmonics During the last few years industries has witnessed
More informationPower Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives
For your business and technology editors Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives The use of AC induction motors is essential for industry and utilities. AC induction
More informationWelcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008
Welcome to the rd Annual Northern Ohio 3 rd Energy Management Conference September 30, 2008 Recover Lost Dollars Demand Side Electrical Energy Savings By Improving Distribution System Efficiency, Capacity
More informationHarmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution
Harmonic Solutions in Electrical Systems Raed Odeh Application Specialist - Power Quality & Electrical Distribution Agenda I. Harmonic Basics II.Harmonic Mitigation Solutions III.Case Study 2 Harmonic
More informationCHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS
84 CHAPTER 4 POWER QUALITY AND VAR COMPENSATION IN DISTRIBUTION SYSTEMS 4.1 INTRODUCTION Now a days, the growth of digital economy implies a widespread use of electronic equipment not only in the industrial
More informationAnalysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar
Analysis and modeling of thyristor controlled series capacitor for the reduction of voltage sag Manisha Chadar Electrical Engineering department, Jabalpur Engineering College Jabalpur, India Abstract:
More informationAPPLICATION GUIDE. Harmonics in HVAC applications
APPLICATION GUIDE Harmonics in HVAC applications Table of contents 4 Harmonics in general and why we should care 4 Introduction 4 Basics of harmonics 5 Causes of harmonic distortion 5 Problems caused
More informationOPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY
OPTIMAL DESIGN OF A SINGLE TUNED PASSIVE FILTER TO MITIGATE HARMONICS IN POWER FREQUENCY D. M. Soomro and M. M. Almelian Department of Electrical Power Engineering, Faculty of Electrical and Electronic
More informationInternational Journal of Advance Engineering and Research Development ANALYSIS AND MITIGATION OF HARMONICS IN MEDICAL FIELD
Scientific Journal of Impact (SJIF): 5.71 International Journal of Advance Engineering and Research Development Volume 5, Issue 04, April -2018 e-issn (O): 2348-4470 p-issn (P): 2348-6406 ANALYSIS AND
More informationE S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --
D.,.,.,. E S C R I P T I V E B U L L E T I N Bulletin DB-106 Square D Company October, 1990 ---1 I SQU ARED COMPANY -- Electrical Power Distribution System - The Heart of the Business From small commercial
More informationA Power Quality Survey on a 22 kv Electrical Distribution System of a Technical Institution as per Standards
Indian Journal of Science and Technology, Vol 9(30), DOI: 10.17485/ijst/2016/v9i30/99034, August 2016 ISSN (Print) : 0974-6846 ISSN (Online) : 0974-5645 A Power Quality Survey on a 22 kv Electrical Distribution
More informationRISH Master Digital Multifunction Instrument with onsite pluggable output options. Application : Product Features:
Application : RISH Master 3430 measures important electrical parameters in 3 phase and single phase Network & replaces the multiple analog panel meters. It measures electrical parameters like AC current,
More informationMulti-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7
White Paper Multi-Pulse Rectifier Solutions for Input Harmonics Mitigation Applicable Product: F7, G7, P7 and E7 Dr. Jun-koo Kang, Yaskawa Electric America Doc#: WP.AFD.02 Copyright Yaskawa Electric America,
More informationAccuSine PCS Active Harmonic Filter. Cruising through rough waves in your electrical network
AccuSine PCS Active Harmonic Filter Cruising through rough waves in your electrical network The Schneider Electric AccuSine power correction system (PCS) injects harmonic current to cancel harmonic current
More informationAPPLICATIONS. AFQ Active Multi-Function Filter. AFQ solves thousands of problems in countless types of installations, in particular the following:
APPLICATIONS AFQ solves thousands of problems in countless types of installations, in particular the following: Data processing centres (DPC) Airports Banking institutions Telecommunications centers Presses
More informationAcknowledgements Introduction p. 1 Electric Power Quality p. 3 Impacts of Power Quality Problems on End Users p. 4 Power Quality Standards p.
Preface p. xv Acknowledgements p. xix Introduction p. 1 Electric Power Quality p. 3 Impacts of Power Quality Problems on End Users p. 4 Power Quality Standards p. 6 Power Quality Monitoring p. 7 Power
More informationPower Quality and Circuit Imbalances Northwest Electric Meter School Presented by: Chris Lindsay-Smith McAvoy & Markham Engineering/Itron
Power Quality and Circuit Imbalances 2015 Northwest Electric Meter School Presented by: Chris Lindsay-Smith McAvoy & Markham Engineering/Itron Summary of IEEE 1159 Terms Category Types Typical Duration
More informationInfluence of Switching Elements on Harmonics and Power Factor Improvement
International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 7, Issue 12 (July 2013), PP. 18-24 Influence of Switching Elements on Harmonics
More informationAccuSine PCS Active Harmonic Filter. Cruise through rough waves in your electrical network
AccuSine PCS Active Harmonic Filter Cruise through rough waves in your electrical network How Can Active Harmonic Filters Solve Power Quality Issues in Your Facility? Power electronic devices that have
More informationAutomatic Power Factor Correction by Using Synchronous Condenser with Continuous Monitoring.
Automatic Power Factor Correction by Using Synchronous Condenser with Continuous Monitoring. Rosni Sayed Rajshahi University of Engineering & Technology Rajshahi-6204 Bangladesh A.H.M Iftekharul Ferdous
More informationECET Modern Power
ECET 273000 Modern Power Course Instructors Course Philosophy This course is an introduction to a wide range of electrical energy systems technologies. Topics include fundamentals of energy conversion,
More informationHow do I Implement Hybrid Solutions for LV Dynamic Power Factor Correction
How do I Implement Hybrid Solutions for LV Dynamic Power Factor Correction + and VarSet Application Note: v1.0 (September 2017) Legal Information The Schneider Electric brand and any registered trademarks
More informationNew power tools provide quality and efficiency By
Typical Delta-wye transformer New power tools provide quality and efficiency By Steve Terry For quite some time, it has been well understood that phase-control SCR dimming systems used in the entertainment
More informationGuide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics
Reactive Power and Harmonic Compensation Guide to Harmonics POWER QUALITY The Basics of Harmonics All business types, commercial, industrial, government and energy/utility have a concern with power quality.
More informationISSN: ISO 9001:2008 Certified International Journal of Engineering and Innovative Technology (IJEIT) Volume 5, Issue 11, May 2016
Power Loss Minimization In Distribution System Using Static VAR Compansator Mohamed Hussien Zahran, Hamdy A. M. Shatla, Salama Abo_Zead Dept. of Electrical Engineering, Al-Azhar University, Cairo, Egypt
More informationUNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49
TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact
More informationNJWA - Harmonics and Drives Proper System Design
Session Goals Larry Stanley, Sr. Regional Business Development Engineer, Water Segment Matthew LaRue, ABB Drives Product Manager Philadelphia District, Baldor of Philadelphia NJWA - Harmonics and Drives
More informationHigh Technology Control
High Technology Control Michael Linden ABB National Drives Manager for High Technology Control Pty Ltd High Technology Control Variable Frequency Drives Variable Voltage Variable Frequency Drives Variable
More information1C.6.1 Voltage Disturbances
2 1 Ja n 1 4 2 1 J a n 1 4 Vo l.1 -Ge n e r a l;p a r tc-p o we r Qu a lity 1. Scope The purpose of this document is to state typical levels of voltage disturbances, which may be encountered by customers
More informationHow adjustable speed drives affect power distribution
How adjustable speed drives affect power distribution Application Note Adjustable speed drives (ASDs) can be both a source and a victim of poor power quality. ASDs as victim loads Although ASDs are usually
More informationLow Pass Harmonic Filters
Exclusive e-rated Provider PRODUCT SHEET HARMITIGATOR TM Low Pass Harmonic Filters A solution for electrical distribution systems that require stable, reliable power, characterized by unparalleled power
More informationActive Harmonic Filter
Reactive Power and Harmonic Compensation Active Harmonic Filter The new StacoSine Plus active harmonic filter is available in 100, 150, 200 and 300 amp assemblies. Modules can be paralleled for a maximum
More informationThree Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology
Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology Riya Philip 1, Reshmi V 2 Department of Electrical and Electronics, Amal Jyothi College of Engineering, Koovapally, India 1,
More informationHarmonic distortion Blackouts Under or over voltage Dips (or sags) and surges, Transients.
Power Quality Standards in India Power Quality is a measure of an ideal power supply system. It can be defined as any power problem manifested in voltage, current and frequency deviations that result in
More informationIMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs
IMPROVING POWER QUALITY AND ENHANCING THE LIFE OF POWER EQUIPMENT, IN RAILWAY TSSs Mr. P. Biswas, ABB ABSTRACT The Indian Railways employ single phase 25 kv Traction sub-station (TSS) for supplying power
More informationHarmonics Reduction using 4-Leg Shunt Active Power Filters
Harmonics Reduction using 4-Leg Shunt Active Power Filters K Srinivas Assistant Professor & Department of EEE & JNTUH CEJ Telangana, India. Abstract Harmonics in power system are caused by highly non-linear
More informationDo Capacitor Switching Transients Still Cause Problems?
Do Capacitor Switching Transients Still Cause Problems? Mark McGranaghan We have been evaluating problems related to capacitor switching transients for many years. Capacitor banks have been used on distribution
More informationMitigation of Voltage Sag and Swell using D-STATCOM to improve Power Quality
Mitigation of Voltage Sag and Swell using D-STATCOM to improve Power Quality Deeksha Bansal 1 Sanjeev Kumar Ojha 2 Abstract This paper shows the modelling and simulation procedure for power quality improvement
More informationDetermination of Optimal Account and Location of Series Compensation and SVS for an AC Transmission System
ISSN (e): 2250 3005 Vol, 04 Issue, 5 May 2014 International Journal of Computational Engineering Research (IJCER) Determination of Optimal Account and Location of Series Compensation and SVS for an AC
More informationSimulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry.
Simulation & Hardware Implementation of APFC Meter to Boost Up Power Factor Maintain by Industry. Bhargav Jayswal 1, Vivek Khushwaha 2, Prof. Pushpa Bhatiya 3 1.2 B. E Electrical Engineering, Vadodara
More informationTechnical Paper. Harmonic Distortion in Data Centers
Technical Paper Harmonic in Data Centers Written By: Ian Wallace Summary Power quality and power reliability are critical to data center operation. As strides have been made to improve energy efficiency
More informationARDUINO BASED POWER FACTOR CORRECTION
ARDUINO BASED POWER FACTOR CORRECTION 1 SHOBHA R.MANE, 2 ASHWINI A.KOLEKAR, 3 MAITHILI M. MOLAJ, 4 SADHANA V.PATIL, 5 MAZHARHUSSAIN N. MESTRI 1,2,3,4,5 Electrical Department, Shivaji University, Kolhapur,
More informationReliable power onboard and offshore
Reliable power onboard and offshore AccuSine PCS+ Active Harmonic Filters For electrical network reliability and quality in Marine 2 What causes harmonics in Marine applications? Power electronics with
More informationThyristorised Real Time Power Factor Correction (TRTPFC)
Thyristorised Real Time Power Factor Correction (TRTPFC) Sanjay N. Patel, 2 Mulav P. Rathod, 3 Keyur C. Patel, 4 Parth H. Panchal, 5 Jaimin N. Prajapati, 2 Asst.Prof, Electrical dept., SVIT Vasad, 3, 4,
More informationEffective Harmonic Mitigation with Active Filters
Advancing Power Quality White Paper Effective Harmonic Mitigation with Active Filters Written by: Ian Wallace Variable Speed Drive with no Harmonic Mitigation Industry standard variable speed drives, with
More informationHow Harmonics have led to 6 Power Factor Misconceptions
Harmonic and Energy Saving Solutions How Harmonics have led to 6 Power Factor Misconceptions Tony Hoevenaars, P.Eng. Power Factor Misconceptions 1. Low power factor is normally caused by electric motors
More informationCONCLUSIONS AND SUGGESTIONS FOR FUTURE WORK
CHAPTER 7 CONCLUSIONS AND SUGGESTIONS FOR FUTURE WORK The objective of this work is to design, fabricate and test a harmonic filter configuration, with simple and effective control algorithm under both
More informationPQ Synergy Effective Harmonic Filter Designs for Commercial Implementation. Team Power Matrix, Sony Jacob.
PQ Synergy 2015 Effective Harmonic Filter Designs for Commercial Implementation Team Power Matrix, Sony Jacob Copyright 2015. POWER MATRIX SOLUTIONS PVT LTD Corporate Power Corporate Quality Highlights
More informationAvailable online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015
Available online at www.sciencedirect.com ScienceDirect Procedia Technology 21 (2015 ) 310 316 SMART GRID Technologies, August 6-8, 2015 A Zig-Zag Transformer and Three-leg VSC based DSTATCOM for a Diesel
More informationHarmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.
Harmonic Mitigation for Variable Frequency Drives HWEA Conference February 15, 2011 Kelvin J. Hurdle Rockwell Bus. Dev. Mgr. 1 OVERVIEW Linear vs. Non- Linear Load Definitions AC Drive Input Current Harmonics
More informationAdvantages There are many diverse advantages of a portable analyzer for the user. The most important is information.
Portable s CIRCUTOR offers a wide range of portable analyzers designed to measure, display and/or record the most important parameters of an electrical network. With the analysis of the electrical parameters,
More informationChapter L Power factor correction and harmonic filtering
Chapter L Power factor correction and 1 2 3 4 5 6 7 8 9 10 Contents Reactive energy and power factor 1.1 The nature of reactive energy L2 1.2 Equipment and appliances requiring reactive energy L2 1.3 The
More informationMIRUS International Inc.
LINEATOR Universal Harmonic Filter for VFD s Questions and Answers This document has been written to provide answers to the more frequently asked questions we have received regarding the application of
More informationII. RESEARCH METHODOLOGY
Comparison of thyristor controlled series capacitor and discrete PWM generator six pulses in the reduction of voltage sag Manisha Chadar Electrical Engineering Department, Jabalpur Engineering College
More informationDATA SHEET POWER CAPACITOR
Issued August 2009 10470 DATA SHEET POWER CAPACITOR General Data * POWER FACTOR CORRECTION The power factor of a load is defined as the ratio of active power to apparent power, i.e. kw : kva and is referred
More informationENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM
ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM Abstract Efficient operation of the electrical system of any facility is essential to controlling operational costs while maximizing
More informationIntroduction to Rectifiers and their Performance Parameters
Electrical Engineering Division Page 1 of 10 Rectification is the process of conversion of alternating input voltage to direct output voltage. Rectifier is a circuit that convert AC voltage to a DC voltage
More informationAPQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)
APQline Active Harmonic Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Power electronic equipment and AC-DC power conversion equipment contribute
More informationVoltage Sag and Mitigation Using Dynamic Voltage Restorer (DVR) System
Faculty of Electrical Engineering Universiti Teknologi Malaysia OL. 8, NO., 006, 3 37 ELEKTRIKA oltage Sag and Mitigation Using Dynamic oltage Restorer (DR) System Shairul Wizmar Wahab and Alias Mohd Yusof
More informationHarmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017
Harmonics and Their Impact on Power Quality Wayne Walcott Application Engineering Manager June, 2017 Presentation Overview A little about harmonics What are harmonics What are NOT harmonics What creates
More informationData Sheet. RISH Master Record %THD
Data Sheet %THD Application : measures important electrical parameters & replaces the multiple analog panel meters. It measures electrical parameters like AC current, Voltage, frequency, active energy
More informationHarmonics Issues that Limit Solar Photovoltaic Generation on Distribution Circuits
WREF 01 Paper # 048 Harmonics Issues that Limit Solar Photovoltaic Generation on Distribution Circuits Ketut Dartawan Ricardo Austria, Le Hui and Mark Suehiro* Pterra Consulting Maui Electric Company*
More informationLow voltage circuit breakers
Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers A-4. Technical information TD & TS MCCB Index Temperature derating Power dissipation / Resistance Application Primary use of transformer
More informationEFFICIENT POWER QUALITY: AN APPROACH TO ENERGY CONSERVATION
EFFICIENT POWER QUALITY: AN APPROACH TO ENERGY CONSERVATION Nirmal Singh 1, Manish Kumar Jain 2 Neeru Goyal 3, Prashant Kumar Tayal 4 1,4 Faculty,Department of Electrical Engg., Dr.K.N. Modi University,
More informationPower Quality Study of Electrical Installation in Academic Institute Case Study
Power Quality Study of Electrical Installation in Academic Institute Case Study Mr. Mukteshwar N. Patil 1, Prof. Rajesh M. Holmukhe 1#, Mr. Sadashiv Munde 2 1 Department of Electrical Engineering, Bharati
More informationVolume I Issue VI 2012 September-2012 ISSN
A 24-pulse STATCOM Simulation model to improve voltage sag due to starting of 1 HP Induction-Motor Mr. Ajay Kumar Bansal 1 Mr. Govind Lal Suthar 2 Mr. Rohan Sharma 3 1 Associate Professor, Department of
More informationFuture. Ready. SM. Using Meters as Distribution Sensors for Capacitor Bank Monitoring. White Paper
White Paper Using Meters as Distribution Sensors for Capacitor Bank Monitoring The role capacitor banks play in maintaining power quality varies by utility. But regardless of how capacitors are deployed,
More informationPower Factor Correction of Inductive Loads using PLC
Power Factor Correction of Inductive Loads using PLC Sayed Abdullah Sadat Member of Regime, National Load Control Center (NLCC) Afghanistan's National Power Utility (DABS) Sayed_abdullah@ieee.org E. Sreesobha
More informationIntroduction: TAS PowerTek Ltd. MAVROS
Introduction: Electrical supply system in today s scenario faces a major challenge due to Power Quality issues. Harmonics on supply system due to Electronics type of loads that are used extensively. Power
More information