PM/PB Series Microprocessor Panel Meter Operation Manual

Size: px
Start display at page:

Download "PM/PB Series Microprocessor Panel Meter Operation Manual"

Transcription

1 PM/PB Series Microprocessor Panel Meter Operation Manual No.6, Tzuchiang St., Tucheng Industrial Park, New Taipei City 6, Taiwan Tel: Fax: http: // 08-PBXXX-B-EM,0//0

2 MENU. Product Introduction. System Block Diagram. Operation Panel, Technical Specification & Installation Dimension. PB-47.. Operation panel.. Technical Specifications.. Relay Outputs..4 Exterior Dimensions.. Panel Cutout Dimensions..6 Terminal Arrangements. PB-470 / PB-70.. Operation panel.. Technical Specifications.. Relay Outputs..4 Exterior Dimensions.. Panel Cutout Dimensions..6 Terminal Arrangements. PB-47.. Operation panel.. Technical Specifications.. Relay Outputs..4 Exterior Dimensions.. Panel Cutout Dimensions..6 Terminal Arrangements.4 PM-40 / PM-0.4. Operation panel.4. Technical Specifications.4. Relay Outputs.4.4 Exterior Dimensions.4. Panel Cutout Dimensions.4.6 Terminal Arrangements. PM-40.. Operation panel.. Technical Specifications.. Relay Outputs..4 Exterior Dimensions.. Panel Cutout Dimensions..6 Terminal Arrangements. Program Settings. Program Settings Flowchart. Input Buttons. Input Signal Module & Settings Method.4 Program Commands List. Input Signal Settings.. Diagram.. Input Signal & Settings Table.. Current Input Example..4 Non-linear feature settings.6 Output Signal Settings.6. Optional Relay Output Settings.6. Analog Output Settings 4. Program Settings Example 4. Diagram of Setting Values 4. Program Settings Example 4.. Example 4.. Example 4.. Example. Frequently Asked Questions & Troubleshooting. Product Introduction PB-470, PB-47, PB-70, PB-47 are bargraph panel meters, with both numeric display and analog bargraph display, perform signal indication and process control. MG series can accept various different signal inputs, digital numeric display could be set to any unit range as required by the user, examples, kg/cm, bar, cm and kg. This feature is very useful and suitable for various electrical and medium measurement controls in various industries. PM-40, PM-0, PM-40 series does not include bargraph, PM-40 is 4 digit display panel meter, PM-0 is digit display panel meter. PM-40, PB-47 features channel independent input signals capability and channel signal outputs. Modbus communication can be downloaded from http: // Feature : Accept all kinds of process signals: 0~0mA, 4~0mA, 0~0mA, 0~4mA, 0~0V, 0~V, ~V, 0~0V, 0~V, also possible to use in non-standard input signal ranges. Continuous capacitance level transmitter. / 4 / 6 / 8 (PB-47) sets of replay outputs and LED indication on front panel face. PM / PB series provide optional volume conversion feature, ideal for use in non-conventional tank level measurement. Optional analog signal output for every signal input. (PB-40, PB-47 have dual inputs and dual outputs) Varity of signal input signals. (refer to ordering guide). Readable range is -999~9999 (4 digits) or -9999~767 ( digits). Input power supply is AC8V~AC6V or dc8~6v. input button control, easy operations.. System Block Diagram AC Power Current Input Voltage Input A D Data Storage E PROM ~ = Excitation Micro processor. Attention: PM / PB series functions are the same but may have different outlook, all diagrams in this manual is based on the outlook of PB-47 D A SP SP SP SP4 SP Control Panel RS48 Voltage Output Current Output 4 or 6 relay contacts to output signal SP6

3 . Operation Panel / Technical Specification / & Installation Dimension. PB-47.. Operation Panel.. Technical Specifications 4 digits, 0.6" 7 segment red LED display... Relay Outputs MAIN OCB SP 6 4 F lnet ek Relay Indicator 0 LED Bargraph UP SFT ER Digital SP4 CTACT SP CTACT SP CTACT SP CTACT SP6 CTACT SP CTACT 0 segment LED red bargraph display. range: -999~+9999 Input Signal Range: 0~0mA, 4~0mA, 0~0mA, 0~4mA, 0~0V. (Refer to Ordering Information for more types) Accuracy: 0.%FS or A digit Temperature coefficient: ppm/bc ADC resolution: 4-/ digit Sampling Rate: 4 samples/second Relay Contact: 4 or 6 relays A 0VAC or A 0VDC (N.C. / N.O. jumper selectable) Working Condition: -0~70BC (0% to 90% RH non-condensed) Storage Condition: -~7BC (0% to 90% RH non-condensed) Power Supply: AC8V~AC6V or DC8V~DC6V Switching Power Supply Power comsumption: 9VA Insulation Voltage: >ACV/min Insulation Resistance: >MW/Vdc/min Optional Output (Isolated): *Analog Output: 0~0mA, 4~0mA, 0~0mA, 0~4mA 0~0V, ~0V, 0~V, ~V. bit DAC resolution All of relay original setting is N.O.. To select N.C. / N.O. setting need from PC Board directly. The 4 sets N.C./N.O. jumper selector are near relay, which design is for user to select N.C./N.O. Type, the diagram is shown below : RY4 RY RY RY..4 Exterior Dimensions.. Cutout Dimensions EXC 4V GND Volt Input Signal Current Input Signal Signal GND SP4 SP SP SP Power Supply (max.) Terminal Arrangements Isolated +4V Isolated GND Isolated analog O/P+ Isolated analog GND (Option) F RS48 (Option) G SP6 SP (Option). F 8G0 0 (min.) F0.6 4G0 0 (min.) ( u n i t:m m ) JP4 JP JP JP NC. NO. NC. NO. NC. NO.NC.NO.NC. NO

4 PB-470 PB-70 MAIN OCB. PB-47 / PB-70.. Operation Panel Relay Indicator.. Relay Outputs LED Bargraph Digital SP4 CTACT SP CTACT SP CTACT SP CTACT SP6 CTACT SP CTACT UP SFT ER.. Technical Specifications 4 digits, 0.6" 7 segment red LED display. 0 segment LED red bargraph display. range: -999~+9999 (PB-470 Series Products) range: -9999~+767 (PB-70 Series Products) Input Signal Range: 0~0mA, 4~0mA, 0~0mA, 0~4mA, 0~0V. (Refer to Ordering Information for more types) Accuracy: 0.%FS or digit Temperature coefficient: ppm/bc ADC resolution: 4-/ digit Sampling Rate: 4 samples/second Relay Contact: 4 or 6 relays, A 0VAC or A 0VDC (N.C./N.O. jumper selectable) Working Condition: -0~70BC (0% to 90% RH non-condensed) Storage Condition: -~7BC (0% to 90% RH non-condensed) Power Supply: AC8V~AC6V or DC8V~DC6V Switching Power Supply Power comsumption: 9VA Insulation Voltage: >ACV/min Insulation Resistance: >MW/Vdc/min Optional Output (Isolated): *Analog Output: 0~0mA, 4~0mA, 0~0mA, 0~4mA 0~0V, ~0V, 0~V, ~V. bit DAC resolution. All of relay original setting is N.O.. To select N.C. / N.O. setting need from PC Board directly. The 4 sets N.C./N.O. jumper selector are near relay, which design is for user to select N.C./N.O. Type, the diagram is shown below : RY4 RY RY RY JP4 JP JP JP NC. NO. NC. NO. NC. NO.NC. NO.NC. NO Exterior Dimensions 0 (min.) 4 F0.6 G0 Isolated +4V EXC 4V (Option) Isolated GND GND Isolated analog O/P+ Volt Input Signal Isolated analog GND Current Input Signal Signal GND 44.. Cutout Dimensions 8 F G0..6 Terminal Arrangements (Option) RS 48 F G 0 (min.) SP SP4 SP SP SP Power Supply 7 (Option) SP ( u n i t:m m )

5 . PB-47.. Operation Panel.. Technical Specifications..4 Exterior Dimensions.. Cutout Dimensions CH Digital Relay Indicator Dual 4 digits, 0.6" 7 segment red LED display. Dual 0 segment LED red bargraph display. range: -999~+9999 Ch in RED color, CH in GREEN color. 48 6(max.) 4 F0.6 G0 0 (min.) MAIN OCB CH-0 LED Bargraph CH-0 LED Bargraph UP SFT ER.. Relay Outputs CH Digital CH SP CH SP CH SP CH SP CH4 SP4 CH SP CH4 SP4 CH SP Input Signal Range: 0~0mA, 4~0mA, 0~0mA, 0~4mA, 0~0V. (Refer to Ordering Information for more types) Accuracy: 0.%FS or A digit Temperature coefficient: ppm/bc ADC resolution: 4-/ digit Sampling Rate: samples/second/chnnel Relay Contact: 4 or 8 relays A, 0VAC or A0VDC (N.C. / N.O. jumper selectable) Working Condition : -0~70BC (0% to 90% RH non-condensed) Storage Condition: -~7BC (0% to 90% RH non-condensed) Power Supply: AC8V~AC6V or DC8V~DC6V Switching Power Supply Power comsumption: VA Insulation Voltage: >ACV/min Insulation Resistance: >MW/Vdc/min Optional Output (Isolated): *Analog Output: 0~0mA, 4~0mA, 0~0mA, 0~4mA 0~0V, ~0V, 0~V, ~V. bit DAC resolution. All of relay original setting is N.O.. To select N.C. / N.O. setting need from PC Board directly. The 4 sets N.C./N.O. jumper selector are near relay, which design is for user to select N.C./N.O. Type, the diagram is showed as below : RY4 RY RY RY JP4 JP JP JP NC. 44 CH CH 44 EXC 4V GND Volt Input Signal Current Input Signal Signal GND Volt Input Signal Current Input Signal Signal GND CH SP CH SP CH SP CH SP Power Supply Terminal Arrangements Isolated +4V Isolated GND Isolated analog O/P+ Isolated analog GND Isolated analog O/P+ Isolated analog GND F RS48 (Option) G CH SP4 CH SP CH SP4 CH SP. 8 F G0 CH CH 0 (min.) ( u n i t:m m ) NO. NC. NC. NO.NC. NO.NC. NO. NO

6 .4 PM-40 / PM-0.4. Operation Panel Digital Relay Indicator.4.4 Exterior Dimensions Technical Specifications 4 digits (PM-40), digit (PM-0) 0.6" 7 segment red LED display. 0 segment LED red bargraph display. range: -999~+9999 (PM-40) -9999~+767 (PM-0) Input Signal Range: 0~0mA, 4~0mA, 0~0mA, 0~4mA,0~0V. (Refer to Ordering Information for more types) Accuracy: 0.%FS or Adigit Temperature coefficient: ppm/bc ADC resolution: 4-/ digit Sampling Rate: 4 samples/second Relay Contact: 4~6 relays, A 0VAC or A 0VDC (N.C./N.O. Jumper selectable).4. Relay Outputs MAIN SP contact SP contact UP SFT ER Working Condition: -0~70BC (0% to 90% RH non-condensed) Storage Condition: -~7BC (0% to 90% RH non-condensed) Power Supply: AC8V~AC6V or DC8V~DC6V Switching Power Supply Power comsumption: 7VA Insulation Voltage: >ACV/min Insulation Resistance: >MW/Vdc/min Optional Output (Isolated): * Analog Output: 0~0mA, 4~0mA, 0~0mA, 0~4mA 0~0V, ~0V, 0~V, ~V. bit DAC resolution. All of relay original seting is N.O.. To select N.C. / N.O. Setting need from PC Board directly. The 4 sets N.C./N.O. jumper selector are near relay, which design is for user to select N.C./N.O. Type, the diagram is shown below :.4. Cutout Dimensions (min) 4 F0.6 G0 9 F0.8 G0 Analog Iso Out GND 0 (min).4.6 Terminal Arrangements (Option) RS-48 SP 4 SP ( u n i t:m m ) (NC/NO) (COM) (NC/NO) (COM) OCB SP4 contact SP contact NC. NO. RY RY JP JP NO. NC. NO. NC EXC GND SIG +4V (IN-) (IN+) (NC/NO) (COM) (NC/NO) (COM) SP SP Power Supply

7 . PM-40.. Operation Panel Digital Relay Indicator..4 Exterior Dimensions Technical Specifications 4 digits, 0.6" 7 segment red LED display. range: -999~+9999 Input Signal Range: 0~0mA, 4~0mA, 0~0mA, 0~4mA, 0~0V. (Refer to Ordering Information for more types) Accuracy: 0.%FS oradigit Temperature coefficient: ppm/bc ADC resolution: 4-/ digit Sampling Rate: samples/second Relay Contact: 4 or 6 relays, A 0VAC or A 0VDC (N.C./N.O. Jumper selectable).. Relay Outputs MAIN SP contact SP contact CH UP SFT ER Working Condition: -0~70BC (0% to 90% RH non-condensed) Storage Condition: -~7BC (0% to 90% RH non-condensed) Power Supply: AC8V~AC6V or DC8V~DC6V Switching Power Supply Power comsumption: 7VA Insulation Voltage: >ACV/min Insulation Resistance: >MW/Vdc/min Optional Output (Isolated): * Analog Output: 0~0mA, 4~0mA, 0~0mA, 0~4mA 0~0V, ~0V, 0~V, ~V. bit DAC resolution. All of relay original setting is N.O.. To select N.C. / N.O. setting need from PC Board directly. The 4 sets N.C./N.O. jumper selector are near relay, which design is for user to select N.C./N.O. Type, the diagram is shown below :.. Cutout Dimensions (min) 4 F0.6 G0 Analog Out 9 F0.8 G0 Iso GND Analog CH Out 0 (min)..6 Terminal Arrangements CH (Option) RS-48 SP SP (NC/NO) (COM) (NC/NO) (COM) ( u n i t:m m ) OCB SP contact SP contact CH NC. NO. RY RY JP JP NO. NC. NO. NC EXC GND CH CH (NC/NO) (COM) (NC/NO) (COM) +4V (IN-) (IN+) (IN+) SP SP Power Supply CH -- --

8 . Program Settings. Program Settings Flowchart PASS CHSL To choose CH or CH from here (0only for PM-40, PB-47 ) CHSL SCL SP~6 H~6 HOF~6 D~6 DOF~6 CH~. Input Buttons Buttons Explanation The settings on the panel meter is controlled by the buttons on the panel (UP, SFT and ER). First choose the function, then input required value of buttons while in "Selection" and "Setting" are: UP SFT ER ER Button Selection Escape Enter Switch Settings Addition Position Shift Confirmation *Please enter password to modify the parameter. (Default password: 4607) ) Main menu switch or sub-menu switch. Example: STEP ~ STEP and STEP ~ STEP. ) Confirmation to save settings Example: Confirmation of change of i value ENB~6 INP ALR~6 FULL STEP i 4 4 Blinking OUT i SIG STEP : modify : save NOLI SEL LP~0 NOLI (Non-Linear Tank Volume Conversion Function):Optional INP STEP CN IDNO i COD SYS LOAD FINE BPS STYL FORN TOUR STEP 4 STEP

9 SFT Button Entry into main menu or entry into sub-menu or position change. Example: STEP, STEP and STEP ~ STEP 7 Position shift After entering into value input, use this button to shift between digit position. STEP SP SETTING STEP STEP SP STEP 4 Moving Numeric : Moving the parameter numeric to modify. For example : Into i function setting, one of the numeric will blinking to modify, and use SFT bottom to select blinking digit for modify. SETTING S C H i SCL 4 4 STEP STEP 6 STEP 7 The blinking digit is for modify SETTING SETTING SETTING. Input Signal Module and Setup Method SIM Input Module Specifications and Jumper Elaboration. Module Input Signal Range Jumper Setting A A A A4 A B B B 4~0mA with Exc+4V A0~0mA with Exc+4V A0~mA with Exc+4V AV with Exc+4V A0 with Exc+4V A0 with Exc+4V AV with Exc+4V ma AC Scaled 0mA AC Scaled ma AC Scaled A AC Scaled A AC Scaled mv AC Scaled mv AC Scaled V AC Scaled DC 4~0mA DC 0~0mA DC 0~mA DC AV DC A0V DC A0V DC AV AC 0~mA AC 0~0mA AC 0~mA AC 0~A AC 0~A DC 0~mV AC 0~mV AC 0~V CH V 0V 0V V 0mA ma CH Left & right Jumpers must change symmetrically. J J4 m 0mA ma mv V ma 0mA ma UP Button B4 0V AC Scaled AC 0~0V 0V V 6V To escape from main menu and to escape from sub-menu to main menu. Example: STEP and STEP STEP I N P To change input value by addition. Example: To change the value of i from "0" to "4", press button four times. S C H i 0 4 B B6 C C C C4 V AC Scaled 6V AC Scaled AmA Exc+4V A0mA Exc+4V AmA Exc+4V AAmp AC 0~V AC 0~6V DC AmA DC A0mA DC AmA DC AA J Left & right Jumpers must change symmetrically. J4 J ma 0mA ma ma 0mA ma i Blinking C D A Amp A0mV Exc+4V DC AA DC A0mV J STEP D D D4 A0mV Exc+4V AmV Exc+4V AmV Exc+4V DC A0mV DC AmV DC AmV mv mv 0mV 0mV

10 .4 Program Commands List Command PASS CHSL SCL SP SP SP SP4 SP SP6 H H H H4 H H6 HOF HOF HOF HOF4 HOF HOF6 D D D D 4 D D 6 Password Description Channel Selection Set,, SCL Decimal point Selection value for SPAN value for SPAN 4 Digital 4 Digit Factory Digital Digit Factory Setting Range Default Setting Range Default CH/CH 4607 CH CH/CH 4607 CH 0~ Dot 0~4 Dot -999 ~ ~ ~ ~ ~ ~ ~ ~9999 ~99 ~99 ~99 ~99 ~99 ~ NULL NULL ~ ~767 Set SP~6, H~6, D~6, DOF~6, ENB~6, ALR~6, FULL SP Set point value SP Set point value SP Set point value SP4 Set point value SP Set point value SP6 Set point value SP Hysterises High Band SP Hysterises High Band SP Hysterises High Band SP4 Hysterises High Band SP Hysterises High Band SP6 Hysterises High Band SP Hysterises Low Band SP Hysterises Low Band SP Hysterises Low Band SP4 Hysterises Low Band SP Hysterises Low Band SP6 Hysterises Low Band SP Delay On Setting SP Delay On Setting SP Delay On Setting SP4 Delay On Setting SP Delay On Setting SP6 Delay On Setting ~ ~ ~ ~ ~ ~767 0~99 0~99 0~99 0~99 0~99 0~ NULL NULL Command DOF DOF DOF DOF4 DOF DOF6 ENB ENB ENB ENB4 ENB ENB6 ALR ALR ALR ALR4 ALR ALR6 FULL inp i out SIG NOLI SEL LP LP LP Description SP Delay Off Setting SP Delay Off Setting SP Delay Off Setting SP4 Delay Off Setting SP Delay Off Setting SP6 Delay Off Setting SP Relay On / Off Selecting SP Relay On / Off Selecting SP Relay On / Off Selecting SP4 Relay On / Off Selecting SP Relay On / Off Selecting SP6 Relay On / Off Selecting SP Hi / Lo Alarm Selection SP Hi / Lo Alarm Selection SP Hi / Lo Alarm Selection SP4 Hi / Lo Alarm Selection SP Hi / Lo Alarm Selection SP6 Hi / Lo Alarm Selection ~99 ~99 ~99 ~99 ~99 ~99 Enter this item for all setting items YES / NO Iutput Type Selection 4 Digital 4 Digit Factory Digital Digit Factory Setting Range Default Setting Range Default OFF OFF LO LO NO Input Signal Setting 4~0 0~999 0~999 0~999 0~999 0~999 0~999 YES / NO SPAN Percentage for SPE mode.0 ~9999 ~ ZERO Percentage for SPE mode ~9999 ~767 Analog Output Type Selection Enable / Disable Control Point # Control Point # Control Point # Output Signal Setting Non-Linear Tank Function OFF OFF LO LO NO 4~ ~0 4~0 OFF 0 OFF

11 Command LP4 Control Point #4 Description 4 Digital 4 Digit Factory Setting Range Default 0 Digital Setting Range Digit Factory Default 0 Command CN Description RS48 Settings Setting Range Factory Default LP Control Point # IDNO Settings ModBus Address 0~ LP6 Control Point #6 0 0 BPS Setting ModBus BaudRate more LP7 Control Point #7 6 6BPS 6 LP8 Control Point # BPS LP9 Control Point # BPS 4 LP0 LP Control Point #0 Control Point # BPS 96BPS LP Control Point # G 44BPS 44 LP Control Point # 6 6 9G 9BPS 9 LP4 Control Point # G 88BPS 88 LP Control Point # G 76BPS 76 LP6 Control Point # STYL Settings Data Type more LP7 Control Point # N 8 Byte, No Parity, Stop Bits 8N LP8 Control Point # N 7 Byte, No Parity, Stop Bits 7N LP9 Control Point # O 7 Byte, Odd Parity, Stop Bits 70 LP0 cod Control Point #0 Change Password E 8N 7 Byte, Even Parity, Stop Bits 8 Byte, No Parity, Stop Bits 7E 8N 8N SYS System Settings 8O 8 Byte, Odd Parity, Stop Bits 80 LOAD Reset to factory default YES/NO NO YES/NO NO 8E 8 Byte, Even Parity, Stop Bits 8E FINE Read Software Version Code 7O 7 Byte, Odd Parity, Stop Bits 70 7E 7 Byte, Even Parity, Stop Bits 7E FORN Settings Data Format more HEX RTU Mode HEX HEX ASCI ASCII Mode ASCII TOUT Time Out ~9999mS ms

12 ..Input Signal Settings This section will elaborate how to adapt to different input signals in the panel meter, by using the correct jumper and using command. Panel meter series can accommodate 6 types of conventional input signals, 0mA, ma, V, 0V, 0V, V, please refer below for setup... Input Signal & Setting Table SIM No. Signal Type Jumper position User Setup () 0~0mA 0-0 STEP : Please confirm the type of input signal STEP : Open up MG casing and locate the SIM input signal module, select the jumper connection that corresponds to the required input signal. 0 & 0 4~0mA 0~0mA 0~4mA 0mA STEP : Enter the main menu of the MG after password input, select and select the correct input signal from the list below. Special range 0~0mA SPE i.. Diagram 48x96 Analog Output Output Control Board Signal Input module Signal lnput 0 AmA Special range 0~mA ma 0-0 SPE i Refer to 4.. AV 0 - Relay Contact Relay Contact AC 0V 04 ~V Special range 0~V V - SPE i Refer to 4.. Board A0V POWER+CPU Board 0 ~0V Special range 0~0V 0V - 0 SPE i Refer to x44 Analog Output Output Control Board Signal Input module Signal lnput 06 A0V Special range 0~0V 0V 0-0 SPE i Refer to 4.. AV 0-0 Relay Contact 07 Special range 0~V V SPE i Refer to 4.. Relay Contact Board AC 0V A AC Current 0~mA ma.0 POWER+CPU Board A AC Current 0~0mA 0mA

13 SIM No. Signal Type Jumper position User Setup () SIM No. Signal Type Jumper position User Setup () A A4 A B B B B4 B B6 AC Current 0~mA AC Current 0~A AC Current 0~A AC Voltage 0~mV AC Voltage 0~mV AC Voltage 0~V AC Voltage 0~0V AC Voltage 0~V AC Voltage 0~6V ma A A mv mv V 0V V 6V Refer to 4.. Refer to 4.. C C C C4 C D D D D4 DC Current AmA DC Current A0mA DC Current AmA DC Current AA DC Current AA DC Voltage A0mV DC Voltage A0mV DC Voltage AmV DC Voltage AmV ma 0mA ma A A 0mV 0mV mv mv

14 .. Current Signal Input Example A. wire 4~0mA current signal input example LevelTransducer..4 Non-linear feature settings Special feature: Non-linear settings could be used in applications concerning non-conventional shaped tanks, thereby solving the problem for level v.s. volume measurement for non-linear tank shapes. EXC ZERO IN v COM w SPAN +4V O/P wire 4~0mA Transmitter EXC 4V A Input PM Panel Meter PASS CHSL INP OUT NOLI To divide the maximum measurement into 0 set points, then configure each of these 0 set points according to the shape of the tank, the panel meter will then calculate a proportional readout from the input signal to reflect the true value according to the Meter settings. SEL LP LP LP LP B. wire 4~0mA current signal input example +4V Signal GND (Shielding) EXC 4V GND A Input PM Panel Meter LP LP6 LP7 LP8 LP9 LP0 LP LP LP LP4 LP LP6 LP7 LP8 LP Set point LP0 LP9 LP8 LP7 LP6 LP LP4 LP LP LP LP0 LP9 LP8 LP7 LP6 LP LP4 LP LP LP LP

15 .6 Output Signal Setting.6. Optional relay output setting The optional relay output is switchable to NO (Normal Open) or NC (Normal Close), it is selectable by the jumper on the OCB (Output Control Board). The default setting is "NO". Model: PB-470, PB-47, PB-70 SP and SP6 relay setting is as below drawing:.6. Analog output signal selection Analog output signal (optional) provides 4~0mA or 0~0V signal, it can be selected by the jumper on the OCB (Output Control Board) for current output 4~0mA or voltage output (0~0V). Model: PB-470, PB-47, PB-70, PB-47 RY RY NO NC SP SP6 CH JP CH JP Model: PB-47 Series SP, SP6, SP7 and SP8 relay setting is as below drawing: Model: PM-40, PM-0, PM-40 Series Channel is selected by JP Channel is selected by JP Model: PM-40, PM-0, PM-40 Jumper is for current output Jumper is for voltage output RY RY NO NO SP7 SP SP6 NC RY NC RY NO NC SP8 RY4 SP SP RY CH CH Jumper is for current output Jumper is for voltage output

16 PASS INP OUT COD SYS 4. Program Setting Example 4. Diagram of Setting Values SIG 4-0 LOAD FINE Program Settings Example i SP4 SP SP SP SCL SPE 4~0mA PB-47 SP(~6) H(~6) HOF(~6) D(~6) DOF(~6) ENB(~6) ALR(~6) FULL Magnetic Float Level Indicator delivers a current output that change proportionately with level. The 4 ~ 0mA output could be used in conjunction with the PB-47 panel meter. Magnetic Float Level Indicator SCL 4.. Example Application example: 4mA represents 0.0 when the tank is empty 0mA represents.0 when tank is full Set point is set at 0% of full tank as low level alarm Set point is set at 40% of full tank as low level alarm Set point is set at 60% of full tank as high level alarm Set point 4 is set at 80% of full tank as high level alarm Linear proportional out signal Proportional output: Empty tank: 0mA, Full tank: 0mA Settings are as follows: INP OUT SCL SP SP SP SP4 SIG ENB ENB ENB ENB4 ALR ALR ALR ALR4 4.. Example (Special input signal range's proportional settings) To address the problem of special input signal range that falls within 4~0mA, use of the command "SPE" is needed to program a proportionate setting for the input. Example is Fine Automation capacitance level indicator, Current Input range is 7mA ~ ma, to display 0.0% ~.0% Formula: i / SCLE set value = Expected signal value SIM signal selection x % Settings are as follow: Input current 7mA ~ ma 7 0 %= % = X i= X%= % 0 INP OUT ISEL i SIG LO LO SPE

17 . Frequently Asked Questions & Troubleshooting 4.. Example Value Settings are as follows: =.0 SCL=0.0 SP=00.0 H=.0 HOF=00.0 D=0 DOF=0 ENB= ALR= Problem Panel Face doesn't lights up Rectification method ) Check power supply wire is it connected wrongly or not connected. ) Check whether the power supply is AC8V ~ 6V. 0 4 Analog Input Relay Contact fails to action ) Check whether LED indication on the panel face is doing action.. Check whether wiring on the terminals are connected correctly Panel face LED indicators and Relay contacts no action or not working properly. ) Enter operation menu, check " " is (Default is ) ) Enter operation menu, check " " " " has any set value. ) Enter operation menu, check " " " " has any set value. 4) Enter operation menu, check " " has the same value as factory default Proportional signal input does not correspond to panel display Enter operation menu, check " ", " ", " ", " " & " " is configured correctly. Set point 's action diagram: OFF Analog Input No change in display and bargraph after proportionate input signal Check input signal connection is connected correctly or is it loose

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter % DC Voltage Hawk II H35 Series Advanced Digital Panel Meter Easily Programmed from the Front Panel User-Friendly Software Functions Include: Password Display Scaling Decimal Point Selection Set Point

More information

Modbus communication module for TCX2: AEX-MOD

Modbus communication module for TCX2: AEX-MOD Modbus communication module for TCX2: Communication Specification TCX2 is factory installed in TCX2 series controllers with -MOD suffix, and is also available separately upon request for customer installation

More information

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8

2F. No.25, Industry E. 9 th Rd., Science-Based Industrial Park, Hsinchu, Taiwan Application Note of OGM220, AN001 V1.8 Application Note of OGM220, AN001 V1.8 1.0 Introduction OGM220 series is a dual channels NDIR module having a digital output directly proportional to CO2 concentration. OGM220 is designed for multi-dropped

More information

DC1010/DC1020/DC1030/DC1040

DC1010/DC1020/DC1030/DC1040 05/0 0-10-10-0-EN Page 1 of DC1010/DC1020/DC100/DC1040 DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of functionality and

More information

Excellent low-cost Process & Temperature Controllers

Excellent low-cost Process & Temperature Controllers C22 C62 C82 C83 Excellent low-cost Process & Temperature Controllers C72 C42 R22 01. High Quality LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. The Fast Sampling Rate in 200

More information

INTRODUCTION. T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing

INTRODUCTION. T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing INTRODUCTION T hank you for your HB8215/HB8216 loadcell indicator purchase. The HB8215 and HB8216 are the best choice for industrial weighing application requiring quality, performance and economy. Please

More information

4-20mA, 0-10V and general process measuring bargraph displays

4-20mA, 0-10V and general process measuring bargraph displays Page 1 of 6 Digital panel meters Large displays Bargraphs Transmitters 4-20mA, 0-10V process input bargraph displays Display almost any physical variable... The bargraph displays on this page accept most

More information

High Performance Process & Temperature Controllers

High Performance Process & Temperature Controllers C22 C62 C82 C83 High Performance Process & Temperature Controllers C72 C42 R22 01. Multi Color LCD Display 02. High Accuracy 18 Bit A-D Input and 15 Bit D-A Output 03. 200 msec Sampling Rate 04. True Universal

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

PLA 33. Power line analyzer. User and service manual. version 2.4

PLA 33. Power line analyzer. User and service manual. version 2.4 PLA 33 Power line analyzer User and service manual version 2.4 Content. Front control panel and terminal plate...3 7.2.2. System frequency setting...0 2. Device description...4 7.2.3. Password protection...0

More information

APPENDIX APPENDIX A 1

APPENDIX APPENDIX A 1 A 1 SPECIFICATIONS Ratings Supply voltage 100 to 240 VAC, 50/60 Hz 24 VAC, 50/60 Hz/24 VDC Operating voltage range 85 to 110% of rated supply voltage Power consumption 7VA 4VA/2.5W Sensor input Thermocouple

More information

ZHUHAI PILOT TECHNOLOGY CO., LTD.

ZHUHAI PILOT TECHNOLOGY CO., LTD. SPM32 Multifunctional Power Meter SPM32 Multifunction Power Meter Installation & Operation Manual V1.0 ZHUHAI PILOT TECHNOLOGY CO., LTD. Danger and warning! This device can be installed only by professionals.

More information

Digital Electric Micrometer. DEG2000 Instruction Manual

Digital Electric Micrometer. DEG2000 Instruction Manual Digital Electric Micrometer DEG2000 Instruction Manual Contents 1. Introduction 1 2. Main Features 1 3. Main Modes 1 4. Names and Functions of Controls and Parts 2 5. Specifications 9 6. Operation 11 6.1

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

VIP Current & Power Multimeter

VIP Current & Power Multimeter VIP Current & Power Multimeter Rev 1.6 Table of Contents 1. Mechanical Installation... 3 2. Wiring diagram... 4 3. Specifications... 5 Technical Specifications... 5 3.2 Measuring Specifications... 5 4.

More information

BS-3520 Digital Indicator

BS-3520 Digital Indicator BS-3520 Digital Indicator The Better Way for Weighing & easurements Table of Contents. Introduction...3 - Trait... 3-2 Warning... 4 2. Specification...5 3. External Size...6 4. Description on Front Panel...7

More information

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification

DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification 01 May 20 30-10-10--EN Page 1 of DC1010/DC1020/DC1030/DC1040/Compact type DIGITAL CONTROLLERS Specification Overview The DC1000 Series are microprocessorbased controllers designed with a high degree of

More information

Installation & Operation Manual ELNet VIP

Installation & Operation Manual ELNet VIP Installation & Operation Manual ELNet VIP Electrical Measurements Table of Contents 1. Mechanical Installation... 1-3 2. Wiring diagram... 2-5 3. Specifications... 3-6 Technical Specifications... 3-6 Measuring

More information

TNM96-ETL Energy Meter & Electrical Powermeter

TNM96-ETL Energy Meter & Electrical Powermeter TNM96-ETL Energy Meter & Electrical Powermeter Celsa Messgeräte GmbH Barthelsmühlring 16, 76870 Kande - Germany Telefon: +49 7275 9883-0; Telefax: +49 7275 9883-33 Web: www.celsagermany.com; E-Mail: info@celsagermany.com

More information

Simplified Operations for TM-3100 Series Digital Tachometer

Simplified Operations for TM-3100 Series Digital Tachometer Simplified Operations for TM-3100 Series Digital Tachometer The TM-3100 series Digital Tachometers has the most fundamental function in rotational measurement of four standard models (rotation speed display,

More information

7 Function description 7.1 Digital filter Alarm output

7 Function description 7.1 Digital filter Alarm output User manual KH300 1 Preface 1.1 Preface ---------------------------------------1 1.2 Parts list---------------------------------------2 1.3 Notice------------------------------------------2 2 General 2.1

More information

PID CONTROLLERS LT SERIES

PID CONTROLLERS LT SERIES PID CONTROLLERS LT SERIES The Axis family of microprocessor based controllerscombine a high degree of functionality and reliability at a very low price, in 4 different formats : 1/16 DIN, 1/8 DIN, 1/ 4

More information

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER

SR25. SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER SHIMADEN DIGITAL CONTROLLER Shimaden, Temperature and Humidity Control Specialists SERIES SR25 MICROPROCESSOR-BASED AUOT-TUNING PID CONTROLLER High Accuracy ±0.1% High Sampling Cycle 0.1 sec. Auto-Tuning

More information

MINI BY-PASS level indicator

MINI BY-PASS level indicator MINI BY-PASS level indicator FEATURES Visible level changes are shown by the flag display Uses engineering plastics(not glass) for safety Compact and easy to install. Optional magnetic switches for high/

More information

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Čapkova 22 678 01 Blansko tel.: +420 516 416942, 419995 fax: +420 516 416963 R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY Display module is designed for measuring the resistance, the signal from the

More information

BATCHMATE 1500 Batch Control Computer Technical Bulletin

BATCHMATE 1500 Batch Control Computer Technical Bulletin TS-5(C) BATCHMATE 5 Batch Control Computer Technical Bulletin DESCRIPTION The BATCHMATE features an 8 digit.55-in. alphanumeric LED display. The pulse input model will accept up to 2, pulses per second

More information

Ultrasonic Level Transmitter.

Ultrasonic Level Transmitter. Ultrasonic Level Transmitter www.fine-tek.com INTRODUCTION The ultrasonic level transmitter is a non-contact, low-cost and easy-to-install measuring device. It can be applied to most industrial applications

More information

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale.

Operation. Displayed channel. Measuring range. Status indication/ remote control Key lock Measuring mode/ time constant. Scale. Electronics & Software Type 5080A... Multichannel Laboratory This universal laboratory charge amplifier can be used for force and torque measurements with piezoelectric dynamometers or force plates. Piezoelectric

More information

SPECIFICATIONS Digital Indicator 1. General

SPECIFICATIONS Digital Indicator 1. General SPECIFICATIS Digital Indicator 1. General The instrument is a digital indicator for the purpose of instrumentation, and suitable for the application in hopper, tank scale, and so on. 2. Specifications

More information

MODEL PAXCDC -SERIAL COMMUNICATIONS PLUG-IN OPTION CARDS

MODEL PAXCDC -SERIAL COMMUNICATIONS PLUG-IN OPTION CARDS Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net Bulletin No. PAXCDC-E Drawing No. LP0402 Released 3/05 MODEL PAXCDC -SERIAL COMMUNICATIONS PLUG-IN OPTION CARDS DESCRIPTION This bulletin serves

More information

Technical Manual. Standard Communication Protocol TA3840C

Technical Manual. Standard Communication Protocol TA3840C TA3840C Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual TA3840C 1 st Edition Released February

More information

Ocean Controls KT-5221 Modbus IO Module

Ocean Controls KT-5221 Modbus IO Module Ocean Controls Modbus IO Module 8 Relay Outputs 4 Opto-Isolated Inputs 2 Analog Inputs (10 bit) 1 PWM Output (10 bit) 4 Input Counters Connections via Pluggable Screw Terminals 0-5V or 0-20mA Analog Inputs,

More information

Characteristics and functioning

Characteristics and functioning Characteristics and functioning /25 ENOD4 PRODUCT RANGE:... 4. General presentation:... 4.2 enodview software tool... 4.3 Versions and options:... 4.3. Versions:...4.3.2 Options :...4.4 Dimensions:...

More information

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

ENA33LCD. Power line analyzer. User and service manual.   Obrezija 5 SI-1411 Izlake ENA33LCD Power line analyzer User and service manual version 2.9 (FW version 6.8 and newer) ETI, d.o.o. Obrezija 5 SI-1411 Izlake www.etigroup.eu/products-services 1. Front control panel and terminal plate

More information

GC83 Digital Indicators & GC93 Digital Meter Relay

GC83 Digital Indicators & GC93 Digital Meter Relay Cat.No. B- GC83 Digital Indicators & GC93 Digital Meter Relay OUTLINE Model GC83 has been designed exclusively for indication. Model GC93 is equipped with a comparator like a relay and is applied to a

More information

Troubleshooting Guide for Aquatrac Smart AS and Flex

Troubleshooting Guide for Aquatrac Smart AS and Flex Troubleshooting Guide for Aquatrac Smart AS and Flex Part 1 Sensors and Analog Signals Alpha Release July 28 th, 2000 Alpha Release Page 1 of 21 Preface Welcome to the Aquatrac troubleshooting guide. This

More information

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40 Digital Panel Meters Current and Voltage Indicator/Controller Type LDM40 Multi-input instrument 4-DGT LED 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements: selectable

More information

ma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals.

ma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals. 1 Definition ma/bcd Converter Model MFC-201 ma/bcd The MFC-201 ma/bcd Converter is a device designed to convert a DC current signal into BCD (8421) signals. 2 Operating Principle An electronic circuit

More information

RUN MAN OUT1 OUT2 FL40

RUN MAN OUT1 OUT2 FL40 MAN RUN OUT1 OUT2 FL40 Iso 5167 mass flow computer Installation and user manual rev. 12/2015 PRELIMINARY INFORMATION This document haves copyright reserved, C Arian. Referred trademarks are of property

More information

Instruction Manual. Digital Panel Meter Model 3153B

Instruction Manual. Digital Panel Meter Model 3153B Instruction Manual Digital Panel Meter I-01999 1. Preface Please take care that this instruction manual is certainly delivered to the person in charge of operating this instrument. For safe use of this

More information

LAUREL ELECTRONICS, INC.

LAUREL ELECTRONICS, INC. LAUREL ELECTRONICS, INC. Laureate True RMS AC Voltage & Current Meter with 1 Cycle Update at 50/60 Hz Features True AC or AC plus DC RMS measurement with crest factor of 3.0 at FS Fast response: reading

More information

Series Valve Temperature Controller. Instruction Sheet

Series Valve Temperature Controller. Instruction Sheet 2013/10/03 Series Valve Temperature Controller Instruction Sheet Thank you very much for choosing Delta DTV series valve temperature controller. Please read this instruction sheet before using your DTV

More information

CM1-VA ECNOMIC VOLT/CURRENT Meter

CM1-VA ECNOMIC VOLT/CURRENT Meter SM-321S CM1-VA ECNOMIC VOLT/CURRENT Meter DESCRIPTION CM1 series Indicator has been designed in simple function and 4 digital 20.0mm LED displays with economic cost. They are can be programmed by tack

More information

Series Temperature Controller Instruction Sheet

Series Temperature Controller Instruction Sheet 2015/4/8 Series Temperature Controller Instruction Sheet Precaution DANGER! Caution! Electric Shock! Do not touch the AC terminals while the power is supplied to the controller to prevent electric shock.

More information

Kelba (Australia) Pty Ltd. PA8101S Manual ~ TABLE OF CONTENTS

Kelba (Australia) Pty Ltd. PA8101S Manual ~ TABLE OF CONTENTS Kelba (Australia) Pty Ltd Tel: Int 61 2 9476 4544 Web: www.kelba.com Email: Kelba@bigpond.net.au PA8101S Manual ~ TABLE OF CONTENTS Chapter 1: Introduction to the PA8101S Indicator (1) Chapter 2: Panel

More information

General Specifications

General Specifications General Specifications GS 77J01Q08-01E Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dual-output Types) General This plug-in type pulse to analog converter

More information

Fluke 125. Getting Started. Industrial ScopeMeter

Fluke 125. Getting Started. Industrial ScopeMeter Fluke 125 Industrial ScopeMeter Getting Started GB Dec 2006, Rev. 1, 09/2009 2006, 2009 Fluke Corporation, All rights reserved. Printed in The Netherlands All product names are trademarks of their respective

More information

FLOW INDICATOR TOTALISER 1008S

FLOW INDICATOR TOTALISER 1008S FLOW INDICATOR TOTALISER MODEL: 1008S Doc FLOW INDICATOR TOTALISER MODEL: 1008S Ref. No: Issue No: 01 User s Manual FLOW INDICATOR TOTALISER 1008S Masibus Automation And Instrumentation Pvt. Ltd. B/30,

More information

JFR Series FMCW Radar Level Transmitter.

JFR Series FMCW Radar Level Transmitter. JFR Series FMCW Radar Level Transmitter www.fine-tek.com PRODUCT INTRODUCTION FMCW Radar level transmitter is a non contact measuring device, which is suitable for high temp., high pressure, and corrosive

More information

DPF-MAC Auto power factor controller

DPF-MAC Auto power factor controller Digital Electric& Electronics System DPF-MAC Auto power factor controller MULTI POWER FACTOR AUTOMATIC MULTI POWER FACTOR AUTOMATIC Introduction DPF-MAC increases usage efficiency by controlling the power

More information

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13. LDI 35 OPERATING INSTRUCTIONS General features 2 Technical features 3 Installation 10 Preliminary operations 12 Front panel description 13 Operating mode 15 Important: We suggest you keep the original

More information

Installation Instructions and Reference Handbook. Installation instructions

Installation Instructions and Reference Handbook. Installation instructions Installation Instructions and Reference Handbook Multi-instrument MIB 7000/7000C/7020 4189320016B (UK) DEIF A/S Product information Installation instructions Basic operation DEIF A/S, Frisenborgvej 33

More information

BAS Integration Manual

BAS Integration Manual Snow Melting Control 680 Introduction BAS Integration Manual Snow Melting 680_B 10/15 Replaces: 04/15 The Snow Melting Control 680 can communicate with a Building Automation System (BAS) using either BACnet

More information

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series

MODEL: 47LPA. [2] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points. Digital Panel Meters 47 Series Digital Panel Meters 47 Series FREQUENCY INPUT DIGITAL PANEL METER (4½ digit, LED display type) Functions & Features 4 ½ digit digital panel meter 1/8 DIN size Accepts a pulse train input to measure rotation

More information

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition

UNICONT. PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1. pmg4111a0600p_01 1 / 24. ST edition UNICONT PMG-400 Universal controller and display unit USER'S AND PROGRAMMING MANUAL 1 ST edition pmg4111a0600p_01 1 / 24 TABLE OF CONTENTS 1. GENERAL DESCRIPTION... 3 2. ORDER CODE... 3 3. TECHNICAL DATA...

More information

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/

Shenzhen ATC Technology CO.,LTD ATC. A-1 Serial Remote I/O Module. User Manual. V1.13 Edit:2018/01/ ATC A-1 Serial Remote I/O Module User Manual V1.13 Edit:2018/01/30-1 - Catalogue 1.The introduction of Modbus protocol...- 3-1.1 Modbus protocol master-slave response process... - 3-1.2 Modbus register

More information

Multi-channel DC power digital isolation transducer manual CE-AD81-34MN3-0.5

Multi-channel DC power digital isolation transducer manual CE-AD81-34MN3-0.5 Multi-channel DC power digital isolation transducer manual CE-AD81-34MN3-0.5 1 Overview The main function of this product is to centralized measurement convert multi-channel standard DC transmission signal

More information

Signal Isolators & Conditioners

Signal Isolators & Conditioners Analog signal or RS485 to PWM Isolation Converter Features: >> Accuracy, linearity error level: 0.1,0.2,0.5 level >> 4-20mA / 0-5V / 0-10V and other standard signal input >> Optional RS485 communication

More information

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202 DMTME-96 2CSG133030R4022 M204675 DMTME-I-485-96 2CSG163030R4022 M204685 2CSG445001D0202 GB Operation and assembly instructions DMTME-96: three-phase multimeter for panel mounting, used also in singlephase

More information

FCR 06, FCR 12. Power factor correction controller. User and service manual

FCR 06, FCR 12. Power factor correction controller. User and service manual FCR 06, FCR 12 Power factor correction controller User and service manual version 2.3 Czech Republic Czech Republic 1 Content 1. Control and signal elements... 3 2. Device description... 4 3. Instruction

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display

More information

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter Field Intelligent Device Series Electromagnetic Flowmeter Converter LF620,LF622 Introduction Combined with a multi-functional converter LF620 (combined type) or LF622 (separate type) equipped with its

More information

GENERAL INFORMATION...5

GENERAL INFORMATION...5 TABLE OF CONTENTS SECTION 1 GENERAL INFORMATION...5 1.1 Device Features and Model Selection... 5 1.2 Correct Usage and Conditions For Safety... 6 1.3 Panel Definitions... 7 1.3.1 Ecras Definitions... 7

More information

FastLink TM. Network. Operation and Installation Manual

FastLink TM. Network. Operation and Installation Manual FastLink TM Network Operation and Installation Manual C6570 C6571 C6571S C6572 C6572S C6573S Store and Forward Controller Network Store and Forward Controller Service Store and Forward Controller Network

More information

Characteristics and functioning

Characteristics and functioning Characteristics and functioning 1/36 enod4-d Characteristics and functioning NU-eNod4D-ETH-E-1014_216710-A 1 ENOD4 PRODUCT RANGE... 5 1.1 General presentation... 5 1.2 Versions and options... 5 1.2.1 Versions...

More information

Model A Milliohm Resistance Tester Operators Manual

Model A Milliohm Resistance Tester Operators Manual Model 5060-05A Milliohm Resistance Tester Operators Manual (C) 2003 HARRIS IRT ENTERPRISES, INC. ALL RIGHTS RESERVED Harris IRT Enterprises, Inc. Digital Milliohm Resistance Tester - Model 5060-05A Equipment

More information

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION ADVANCED - CONTROLLERS - SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION (ma) OUTPUTS - 4x EVENT OR ALARM OUTPUTS

More information

Contactor-less Magnetic Brake Controller

Contactor-less Magnetic Brake Controller Contactor-less Magnetic Brake Controller (TCB-series) T.H. ELEMA TEL: +82-31-498-9270-4 FAX: +82-31-498-9275 1. INTRODUCTION TCBseries developed by T.H. ELEMA is a type of reducing maintenance problems,

More information

UL CONDITIONS OF ACCEPTABILITY

UL CONDITIONS OF ACCEPTABILITY Certificate Number: 1018011-1 Date: 2016-10-06 UL CONDITIONS OF ACCEPTABILITY Company Name: FUTURE DESIGN CONTROLS INC File-CCN: E197216 - QUYX2 Product Description: Process Control Equipment, Electrical

More information

Micro-controller X Model: PXE4. Operation Manual. INP-TN5A1887a-E

Micro-controller X Model: PXE4. Operation Manual. INP-TN5A1887a-E Micro-controller X Model: PXE4 Operation Manual INP-TN5A1887a-E 2 BEFORE USE Thank you very much for purchasing Fuji s digital controller. (1) Be sure to read this manual and grasp the concept before operating

More information

PM-PA/PM-PAC POWER ANALYZER

PM-PA/PM-PAC POWER ANALYZER PM-PA/PM-PAC POWER ANALYZER 1. INTRODUCTION Power Analyzer is an ideal device to control measure and monitor all electrical parameters of a system. Thanks to its four display rows, all parameters can be

More information

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual

Carbon Dioxide (Tiny CO2) Gas Sensor. Rev TG400 User Manual Carbon Dioxide (Tiny CO2) Gas Sensor Rev. 1.2 TG400 User Manual The TG400 measuring carbon dioxide (chemical formula CO2) is a NDIR (Non-Dispersive Infrared) gas sensor. As it is contactless, it has high

More information

SUPPLY NETWORK ANALYZER CVM-96 SERIES

SUPPLY NETWORK ANALYZER CVM-96 SERIES SUPPLY NETWORK ANALYZER CVM-96 SERIES (Power Demand) INSTRUCTION MANUAL ( M 981 326 / 00B - GB) (c) CIRCUTOR S.A. ----- Supply network analyzer CVM-96 ------ User's manual --- Page No. 1 CVM-96 SUPPLY

More information

Microprocessor Control Board Set Up Procedures (OR PLC)

Microprocessor Control Board Set Up Procedures (OR PLC) Microprocessor Control Board Set Up Procedures (OR-00 PLC) SWITCHES/PUSHBUTTONS Push Buttons at display SW Enter button SW Back button SW Down SW UP Back light on/off switch Rotary switches on main board

More information

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors. SilverMax Datasheet NEMA 23 Servomotors QuickSilver Controls, Inc. www.quicksilvercontrols.com SilverMax Datasheet - NEMA 23 Servomotors 23 Frame Sizes: 23-3, 23-5, 23H-1, 23H-3, 23H-5 / Series: E, E3,

More information

Kotron Sentinel Model 804 RF Level Transmitter

Kotron Sentinel Model 804 RF Level Transmitter Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading edge microprocessor-based circuitry has nonvolatile memory. The display

More information

JTR Guided Wave Radar Level Transmitter.

JTR Guided Wave Radar Level Transmitter. JTR Guided Wave Radar Level Transmitter www.fine-tek.com PRODUCT INTRODUCTION OPERATING PRINCIPLE The guided wave radar level transmitter is a solid and liquid level measuring instrument commonly used

More information

Ultrasonic Multiplexer OPMUX v12.0

Ultrasonic Multiplexer OPMUX v12.0 Przedsiębiorstwo Badawczo-Produkcyjne OPTEL Sp. z o.o. ul. Morelowskiego 30 PL-52-429 Wrocław tel.: +48 (071) 329 68 54 fax.: +48 (071) 329 68 52 e-mail: optel@optel.pl www.optel.eu Ultrasonic Multiplexer

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 77842-9010 T: 800-876-1172 Int l: (979) 690-5560, Fax: (979) 690-0440 E-mail : globalw@globalw.com Radar Level Transmitters

More information

OVEN INDUSTRIES, INC. Model 5C7-362

OVEN INDUSTRIES, INC. Model 5C7-362 OVEN INDUSTRIES, INC. OPERATING MANUAL Model 5C7-362 THERMOELECTRIC MODULE TEMPERATURE CONTROLLER TABLE OF CONTENTS Features... 1 Description... 2 Block Diagram... 3 RS232 Communications Connections...

More information

DC Current Transducers

DC Current Transducers Current Transducers are designed to provide an analog current reading for monitoring, data logging and panel meter applications. NK Technologies current transducers offer a choice of 5 VDC, 1 VDC or ma

More information

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model 6012-06XR Specifications & Dimensions 2 Theory of Operation 3 System Block Diagram 4 Operator Controls & Connectors 5 Test Connections

More information

USER S MANUAL. Manual for Panel Mount Process Indicator. HTA INSTRUMENTATION (P) LTD. Your One Stop for Instrumentation, Calibration & Service

USER S MANUAL. Manual for Panel Mount Process Indicator. HTA INSTRUMENTATION (P) LTD. Your One Stop for Instrumentation, Calibration & Service Member of SN Registrars (Holdings) Ltd 8327 USER S MANUAL Manual for Panel Mount Process Indicator EQ-DS8B-IRRB EQ-DS8B-IRRB HTA INSTRUMENTATION (P) LTD. Your One Stop for Instrumentation, Calibration

More information

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3

POWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3 POWER SERIES Plus Volt / Amp / Hertz Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology. Careful

More information

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com

More information

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS

sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INSTRUCTIONS MANUAL IM831-U v0.92 HRI-R40W sw rev. 55B DEVICE FOR THE PERMANENT CONTROL OF INSULATION ON THE SUPPLY LINES IN MEDICAL PRACTICE PLACES INSTALLATIONS INDEX: GENERAL TYPES ACESSORIES AND OPTIONS

More information

BC145 SIGNAL ISOLATOR BOARD

BC145 SIGNAL ISOLATOR BOARD BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download

More information

Product Specification for model TT Transducer Tester Rev. B

Product Specification for model TT Transducer Tester Rev. B TT Rev B April 20, 2010 Product Specification for model TT Transducer Tester Rev. B The Rapid Controls model TT Rev B transducer tester connects to multiple types of transducers and displays position and

More information

ENGLISH OPERATING INSTRUCTIONS. General Features 2. Technical Features 3. Installation 9. Preliminary Operations 11. Front Panel Description 12

ENGLISH OPERATING INSTRUCTIONS. General Features 2. Technical Features 3. Installation 9. Preliminary Operations 11. Front Panel Description 12 MDI40 OPERATING INSTRUCTIONS General Features 2 Technical Features 3 Installation 9 Preliminary Operations 11 Front Panel Description 12 Operating mode 15 Important: We suggest you keep the original packing

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller

More information

SHIMADEN DIGITAL INDICATORS

SHIMADEN DIGITAL INDICATORS Shimaden, Temperature and Humidity Control Specialists C %RH Series SD16A & SHIMADEN DIGITAL INDICATORS approved,ul applied BASIC FEATURES compliance DIN Size 48 x 96 mm ±.3% High Accuracy Indication Large

More information

OPTIVENT ULTRA VAV damper CONTROL UNIT FOR MODBUS 227VMZ-MB

OPTIVENT ULTRA VAV damper CONTROL UNIT FOR MODBUS 227VMZ-MB OPTIVENT ULTRA VAV damper CONTROL UNIT FOR MODBUS 227VMZ-MB 2 OPTIVENT ULTRA OPTIVENT ULTRA WITH COMPACT CONTROLLER FOR MODBUS 227VMZ-MB OPTIVENT ULTRA is a complete VAV unit consisting of a Modbus actuator,

More information

True RMS Bench Multimeters 2831E and 5491B

True RMS Bench Multimeters 2831E and 5491B Data Sheet True RMS Bench Multimeters and TRUE RMS True RMS Bench Multimeters with Dual Display The B&K Precision models and are versatile and dependable bench multimeters suitable for applications in

More information

FMCW Radar Level Transmitter. visit our website

FMCW Radar Level Transmitter. visit our website FMCW Radar Level Transmitter visit our website PRODUCT INTRODUCTION FMCW Radar level transmitter is a non contact measuring device, which is suitable for high temp., high pressure, and corrosive applications.

More information

MICRO-CONTROLLER X (48 48 mm)

MICRO-CONTROLLER X (48 48 mm) PX series digital temperature controller MICRO-CONTROLLER X ( mm) DATA SHEET PXG PXG is a compact size temperature controller of front panel size mm. To cope with any of versatile uses as a temperature

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

Load cells connection. Supply and relay connection. AC digital input connection. DC digital input connection. -20 o C ~ 60 o C. Operating Temperature

Load cells connection. Supply and relay connection. AC digital input connection. DC digital input connection. -20 o C ~ 60 o C. Operating Temperature Operating Voltage Power Consumption Operating Temperature Load Cell Excitation Relay Outputs Digital Inputs (AC) A/D Sampling speed Display Analog Input range Input impedance Size 230VAC,50Hz Approx. 3VA

More information

N1040i Indicator. UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V1.0x D PRESENTATION FEATURES

N1040i Indicator. UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V1.0x D PRESENTATION FEATURES UNIVERSAL INDICATOR INSTRUCTIONS MANUAL V1.0x D PRESENTATION N1040i is a quite versatile process indicator. With a wide list of input types - thermocouples, thermo-resistance, voltage and current the N1040i

More information

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value.

MODEL: M2XPA3. [2] EXCITATION 2: 4 V DC / 20 ma 3: 8 V DC / 20 ma 4: 12 V DC / 20 ma Configurator software is used to change the excitation value. Super-mini Signal Conditioners Mini-M Series FREQUENCY TRANSMITTER (PC programmable) Functions & Features Converts the output from a pulse-type transducer into a standard process signal PC programmable

More information