OSS series. Automatic Transfer Switches. O-Sung Electric Machinery CO., LTD.

Size: px
Start display at page:

Download "OSS series. Automatic Transfer Switches. O-Sung Electric Machinery CO., LTD."

Transcription

1 OSS series Automatic Transfer Switches OSung Electric Machinery CO., LTD.

2 Outstanding technology captivates the world! Superior Quality satisfies our customers! Contents Company History 3 OSS T, TB Type (60~400A) 4 Information to Order ( Features ( Specification ( Outline Dimension ( Wiring Diagram ( OSS TN, TBN Type (60~600A) 7 Information to Order ( Features ( External View ( Application and Selection ( Specification ( Outline Dimension ( Wiring Diagram ( OSS PC Type (800~6300A) 12 Information to Order ( Features ( Specification ( Outline Dimension ( Wiring Diagram ( ATS Controller 21 Specification & Function ( Wiring Diagram ( ACD21, ACSD, ACD Technical Details ( ) 24 Safety Manual ( ) 26 2 I Automatic Transfer Switches

3 Company History Dec Established Osung Industrial Oct Become member of Korea Electrical Manufacturers Association.(KOEMA) Aug Incorporated as OSung Electric Machinery Co., LTD. Feb Awarded honor of KOEMA for products development. Mar Nominated as Technology Intensive Enterprises by the Ministry of commerce & Industry. Jan Authenticated of Quality product for Automatic Transfer Switch by the Office of Industrial Advancement Administration. Nov Awarded the Presidential Prize at contest for Quality Control. Nov Awarded Certificate of Quality system by Korean Standards Association Quality Assurance. (KSA9001:1998, ISO9002:1994) Feb Awarded Certificate of Quality system by Korea Management Association Quality Assurance. (KSA9001:1998, ISO9001:1994) Apr ASTA certified for 2000A, 50kA Air Circuit Breaker. Feb ASTA certified for 1600A. 3200A & 5000A 65kA Air Circuit Breaker. May Certified by Taiwan Power Corporation. (TPC) May CE Marked for 200A ATS by TUV. Aug CB Test Certified by KTL for ACB with electronic overcurrent protection. Nov CE Marked for 630A~1600A ACB by TUV. Dec Certified by Chinese Compulsory Certification (CCC) for ACB for 630~1600A ACB Feb Certified by Chinese Compulsory Certification (CCC) for ACB for 2000A~3200A ACB Apr Low pressure air circuit breaker (SB620~632 3Ps, 4Ps 600V 65 kas) CE mark acquisition Apr NET (New Excellent Technology) certification : Automatic Transfer Circuit Breaker Automatic Transfer Switches I3

4 OSS T, TB Type ATS(60~400A) Information to Order OSS 6 P A B C D A 06 60A Rated Current 1 100A 2 200A 4 400A B Type T : TType TB : TBType C Number of Poles 2 : 2P 3 : 3P 4 : 4P D Operating Voltage A1 : AC 110V A2 : AC 220V D1 : DC 110V D2 : DC 125V Features Certain operation by latching mechanism High current capability with low operating current Excellent open and close performance Compact and light weight. Suitable for emergency power supply facilities. Specification TYPE 606T, 606TB 61T, 61TB 62T, 62TB 64T, 64TB Rated Operational Voltage Ue AC 600V, DC 125V Rated Current Ie 60A, 100A 200A 400A Neutral Phase Current 60A, 100A 200A 400A Kind of Throw Double Throw Connection Front( T), Back( TB) Number of poles 2P 3P 4P 2P 3P 4P 2P 3P 4P Weight 14kg 16kg 18kg 16kg 19kg 22kg 16kg 19kg 22kg Rated ShortTime Withstand Current (1sec) Icw 5kA 10kA 12kA ShortCircuit Making Capacity Switching Capacity Switching Frequency Operating Current Operating Time Number of Operating Cycles DC 110V ~125V AC 100V ~110V AC 200V ~ 240V Change over time Opening time Without Current With Current Icm 7.65kA 17kA 24kA AC 33B (6Ie making / 6Ie breaking cos = 0.5 ) DC 31B (1.5Ie making / 1.5Ie breaking L/R = 1ms ) 60 times per an hour 14A 14A 7A/14A 7A/14A 3.5A/7A 3.5A/7A 80 ms 60 ms 10,000 5,000 14A 7A/14A 3.5A/7A Cautions 1. For complete operation, Be sure to provide control source for more than 0.5sec. 2. If the control sources are supplied to A side and B side at the same time, the switching coil can be damaged. 3. Control Relay should be selected considering sufficient contact capacity to withstand against more than control current I Automatic Transfer Switches

5 OSS T, TB Type ATS(60~400A) Outline Dimension OSS T Type Operating circuit terminal Manual handle inlet A Power source side main circuit terminal A Load side main circuit terminal B Power source side main circuit terminal B Change over indicator OSS TB Type PANEL CUT Automatic Transfer Switches I 5

6 OSS T, TB Type ATS(60~400A) Wiring Diagram AC 110V, AC 220V DC 110V, DC 125V Standard Typical Operating Circuit Using a changeover switch Using a timer AC Operating and Control Wiring Diagram DC Operating and Control 6 I Automatic Transfer Switches

7 OSS TN, TBN Type ATS(60~600A) Information to Order A Rated Current A 100A 2 200A 4 400A 6 600A B Type TN : TNType TBN : TBNType C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS 6 P A B C D D Operating Voltage A1 : AC 110V A2 : AC 220V D1 : DC 110V D2 : DC 125V Features Off position stop method In case with the uninterrupted power system, it is recommended to stop at the OFF position set by tripping mechanism for the stable power. Instantaneous transfer without stop can be also performed by operating signal. A Off B, B Off A, and A Off A, B Off B And also, instantaneous transfer can be performed by operating signal. OneCoil Application Onecoil is employed for the transfer to normal power source and emergency power source. Compact & Lightweight Design Compact & lightweight design makes the minimized mounting space and convenient installation. Excellent Breaking Capacity Designed for suffciently large chamber to extinguish the arc when transferred. Arcextinguishing area is designed for convenient inspection and maintenance. Protection against the remaining power source Time delay to transfer is available so that the remaining power can not be induced to the main power to protect the load. Construction for Safety For safe operation, molded construction is employed on breaking parts. And also, latching indicator is prepared to indicate the operating condition. A Off B, B Off A, and A Off A, B Off B A B B A External View Earthing Terminal Manual Operating Shaft (AntiClockwise) Circuit Diagram Name Plate Trip Button Selective Button for B PowerClosing On/Off Indicator Circuit Terminal for A Power Contacts ArcExtinguishing Chamber Aux Switch Circuit Terminal for B Power Control Circuit Terminal Block Main Circuit Terminal for Load Amateur for Closing Coil Automatic Transfer Switches I 7

8 OSS TN, TBN Type ATS(60~600A) Application and Selection Applicable Standards IEC JEM 1038 UL 1008 KSC 4504 KSC 0703 Control Order It is recommended to give more than 0.5 sec for operation, though transfer time is completed within 0.3 sec. Interlock Interlocking is required for control circuit so that control order should not suppy to both A power source side and B power source side simultaneously. For TN type ATS, Sequence setting is required so that closing or tripping order should not supply in the same direction. Control Circuit ATS is designed so that operation current should be off by internal switch after completion of operation. If operation current is off with auxiliary switch of the unit, it may cause a malfunction. IEC JEM 1038 UL 1008 KSC 4504 KSC 0703 Specification Operating Current Operating Time Number of Operating Cycles TYPE Rated Operational Voltage Rated Current Neutral Phase Current Kind of Throw Connection Number of poles Weight Rated ShortTime Withstand Current (1sec) ShortCircuit Making Capacity Switching Capacity Switching Frequency Ue Ie Icw Icm DC 110V ~ 125V AC 100V ~ 110V AC 200V ~ 240V Trip Coil Current Making A POWER Breaking Making B POWER Breaking Without Current With Current 606TN, TBN 61TN, TBN 62TN, TBN 64TN, TBN 66TN, TBN AC 600V, DC 125V 60A, 100A 60A, 100A 200A 200A 400A, 600A 400A, 600A Double Throw Front( TN), Back( TBN) 2P 3P 4P 2P 3P 4P 2P 3P 4P 7kg 8kg 9kg 9kg 10kg 12kg 16kg 19kg 22kg 5kA 10kA 12kA 7.65kA 17kA 24kA AC 33B (6Ie making / 6Ie breaking cos = 0.5 ) DC 31B (1.5Ie making / 1.5Ie breaking L/R = 1ms ) 60Time / Hour 6A 6A 3A/6A 3A/6A 1.5A/3A 1.5A/3A DC 110V = 2.5A, AC 110A = 2.5A, AC 220V = 1.5A 55 ms 55 ms 20 ms 20 ms 80 ms 80 ms 20 ms 20 ms 10,000 5,000 7A 3.5A/7A 2A/3.5A 60 ms 25 ms 90 ms 25 ms Cautions 1. For complete operation, Be sure to provide control source for more than 0.5sec. 2. When control source will be provided to A side and B side simultaneously, Coil may be damaged. 3. Control Relay should be selected considering sufficient contact capacity to withstand against more than control current I Automatic Transfer Switches

9 OSS TN, TBN Type ATS(60~600A) Outline Dimension 60A, 100A 606TN, 61TN 200A 62TN 400A, 600A 64 TN, 66TN * Arc space for main circuit 30mm for AC 220V 60mm for AC 660V Automatic Transfer Switches I 9

10 OSS TN, TBN Type ATS(60~600A) Outline Dimension 606TBN~66TBN * Arc space for main circuit 30mm for AC 220V 60mm for AC 600V PANEL CUTTING TERMINAL THICKNESS 10 I Automatic Transfer Switches

11 OSS TN, TBN Type ATS(60~600A) Wiring Diagram Typical Operating Circuit Standard Using a changeover switch Using a timer Using a condensor tripping device Automatic Transfer Switches I 11

12 OSS PC Type ATS(800~6,300A) Information to Order OSS 6 P A B C D E A Rated Current A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6300A B Type PC : Standard C Number of Poles 3 : 3P 4 : 4P D Operating Voltage A1 : AC 110V A2 : AC 220V D1 : DC 110V D2 : DC 125V E Mounting System F:Fixed D : Draw out Features One coil mechanism One coil mechanism is applied. Transfer indicator provided Transfer indicator is fitted to indicate the transfer status. Easier busbar arrangement If the ATS is installed with the ACB in switchgear, Busbars can be easily arranged. Fixed type & Drawout type available Fixed type and Drawout type are available for customer's convenient applicaion. Quick replacement of ATS If malfunction occurs, drawout type of ATS can be changed within 5 minutes. Perfect transfer mechanism By spring transfer mechanism, ATS can be completely and perfectly transferred. There will be NO unattached position in any case. Sufficient current capacity Sufficient current carrying contacts are designed to withstand against over current. Minimized opening & Closing impact Opening and closing impact is minimized. 12 I Automatic Transfer Switches

13 OSS PC Type ATS(800~6,300A) Specification Rated Voltage Rated Current Neutral Phase Current Kind of Throw Connection Number of Poles Weight Operating Current Operating Time Cautions TYPE 608PC 610PC 612PC 616PC 620PC Fixed Drawout Ue Rated ShortTime Withstand Current (1sec) Icw ShortCircuit Making Capacity Switching Capacity Switching Frequency Number of Operating Cycles DC 110V ~ 125V AC 100V ~ 110V AC 200V ~ 240V Change over time Opening time Without Current Ie Icm 3P 55kg 80kg 800A 800A 25kA 52.5kA 4P 65kg 95kg 3P 55kg 80kg 1000A 1000A 25kA 52.5kA 4P 65kg 95kg AC 600V, DC 125V 1250A 1250A Double Throw Back 3P 4P 60kg 70kg 90kg 105kg 30kA 63kA 1600A 1600A 3P 4P 65kg 75kg 95kg 110kg 35kA 73.5kA With Current 1. For complete operation, Be sure to provide control source for more than 0.5sec. 2. When control source will be provided to A side and B side simultaneously, Coil may be damaged A 2000A 3P 4P 90kg 110kg 110kg 140kg 40kA 84kA AC 33B (6 Ie making / 6 Ie breaking cos = 0.5 ) DC 31B (1.5 Ie making / 1.5 Ie breaking L/R = 1ms ) 60Time / Hour 20Time / Hour 10Time / Hour 45A 23A/45A 15A/30A 50A 25A/50A 20A/40A 65A 33A/65A 25A/50A 120 ms 90 ms TYPE 625PC 632PC 640PC 650PC 663PC Rated Voltage Ue Rated Current Ie Neutral Phase Current Kind of Throw Connection Number of Poles Fixed Weight Drawout Rated ShortTime Withstand Current (1sec) Icw ShortCircuit Making Capacity Switching Capacity Switching Frequency Operating Current Operating Time Number of Operating Cycles Cautions Icm 3P 90kg 110kg 2500A 2500A 50kA 105kA 4P 110kg 140kg 3P 100kg 125kg 3200A 3200A 50kA 105kA 4P 120kg 155kg AC 600V, DC 125V 4000A 5000A 4000A 5000A Double Throw Back 3P 180kg 220kg 4P 220kg 275kg 3P 185kg 245kg 4P 230kg 305kg 65kA 143kA 65kA 143kA AC 33B (6 Ie making / 6 Ie breaking cos = 0.5 ) DC 31B (1.5 Ie making / 1.5 Ie breaking L/R = 1ms ) 10Time / Hour DC 110V ~ 125V AC 100V ~ 110V AC 200V ~ 240V Change over time Opening time Without Current With Current 65A 33A/65A 25A/50A 120 ms 90 ms 80A 40A/80A 33A/65A 1. For complete operation, Be sure to provide control source for more than 0.5sec. 2. When control source will be provided to A side and B side simultaneously, Coil may be damaged A 6300A 3P 4P 200kg 250kg 245kg 305kg 65kA 143kA Automatic Transfer Switches I 13

14 OSS PC Type ATS(800~6,300A) Outline Dimension 800~1600A Fixed unit : mm OSS608~610PC OSS612PC OSS616PC 14 I Automatic Transfer Switches

15 OSS PC Type ATS(800~6,300A) Outline Dimension 2000~3200A Fixed unit : mm OSS620~625PC OSS632PC Automatic Transfer Switches I 15

16 OSS PC Type ATS(800~6,300A) Outline Dimension 4000~6300A Fixed unit : mm OSS640PC OSS650~663PC Panel cutting (Fixing hole) 16 I Automatic Transfer Switches

17 OSS PC Type ATS(800~6,300A) Outline Dimension 800~1600A Draw Out unit : mm OSS608~610PC OSS612PC OSS616PC Automatic Transfer Switches I 17

18 OSS PC Type ATS(800~6,300A) Outline Dimension 2000~3200A Draw Out unit : mm OSS620~625PC OSS632PC 18 I Automatic Transfer Switches

19 OSS PC Type ATS(800~6,300A) Outline Dimension 4000~6300A Draw Out unit : mm OSS640PC OSS650~663PC Automatic Transfer Switches I 19

20 OSS PC Type ATS(800~6,300A) Wiring Diagram AC 110V, AC 220V DC 110V, DC 125V Standard Typical Operating Circuit Using a changeover switch Using a timer Wiring Diagram AC Operating and Control DC Operating and Control Caution : More than 2.5mm 2 power cable used for less than 1,600A ATS. More than 4.0mm 2 power cable used for more than 2,000A ATS. 20 I Automatic Transfer Switches

21 ATS Controller ACD21 / ACSD External View Bpower source indicating LED for Emergency Apower source indicating LED for Utility ATS Apower transfer status indicating LED SYC(Inphase Monitor) indicating LED Selection switch of Apower source Selection switch of Bpower source ATS Bpower transfer status indicating LED Selection switch of automatic or manual Specification Rated operating voltage : 220VAC Frequency : 50 / 60Hz Contacts capacity for ATS control : AC250V, 10A (Noload contacts) Contacts capacity for Abnormal power source : AC250V, 10A (Noload contacts) Basic Function Automatic or manual ATS control Indicating lights for Apower (Utility), Bpower (Emergency) and ATS transfer status Power source : Apower (Green LED), Bpower (Red LED) (Displayed when voltage is above 85%) Transfer status : Apower (Green LED), Bpower (Red LED) Manual operation buttons For Apower(Utility) : Green For Bpower(Emergency) : Red Note : Builtin LED is on for selective button Setting for automatic transfer time Time setting at rear side to avoid unnecessary setting change Variable time settings (0~30sec) While timer is working, indicating lamp for transferable ATS is flickering Detection for open phase of Utility power source (For 3 4W, 220/380VAC only) Detecting the power failure, low voltage and abnormal condition of Utility source, the ACD sends the engine starting signal to the Generator. Inphase Monitor On & Off of InPhase Monitor can be selected by selection switch Option When InPhase Monitor is selected, Transfer is made manually or automatically when synchronized. When Inphase Monitor is not selected, synchronizing indication lamp is not on. When synchronized, Yellow LED is flickered. When synchronized more than 3 cycles, Tranfer will be made. Under the manual mode, when the selection button is selected for Utility or Generator, Built in LED will be flickering until synchronized. Ordering Information ACD21 (ATS control device) : Basic Function ACSD (ATS control synchronizing device) : Builtin Inphase Monitor Option Automatic Transfer Switches I 21

22 ATS Controller ACD21 / ACSD Wiring Diagram 3 4W 380/220V 3 4W 220/127V 3 3W 220V OSS T, TB Type OSS TN, TBN Type OSS PC Type Outline Dimension 22 I Automatic Transfer Switches

23 ATS Controller ACD Controller Specification Rated operating voltage : 220VAC Frequency : 50 / 60Hz Contacts capacity for ATS control : AC250V, 10A (Noload contacts) Contacts capacity for Abnormal power source : AC250V, 10A (Noload contacts) Fitment : Front Type Basic Function Automatic or manual ATS control Builtin indicator for Apower (Utility), Bpower (Emergency) and ATS transfer status Power source : Apower (Green LED), Bpower (Red LED) (Displayed when voltage is above 85%) Transfer status : Apower (Green LED), Bpower (Red LED) Manual operation buttons For Apower(Utility) : Green For Bpower(Emergency) : Red Note : Builtin LED is on for selective button Setting for automatic transfer time Transferring time setting is available at rear side to avoid unnecessary touch. Variable time settings (0~30sec) While timer is working, indicating lamp for transferable ATS is flickering Detection for open phase of Utility power source (For 3 4W, 220/380VAC only) Monitering for power failure, and low voltage of A power and B power. Wiring Diagram OSS PC Type OSS TN, TBN Type OSS T, TB Type PANEL CUTTING : W157 H131 (unit:mm) Automatic Transfer Switches I 23

24 Technical Details Standard Operating Conditions Ambient Temperature: 5 C~+40 C(but, the average temperature for 24 hours shall be lower than +35 C) Altitude: Below 2000m Environmental conditions Relative humidity shall be less than 85% at max. temp. +40 C, less than 90% at 20 C It shall not be allowed to use or store within the area of petrochemicals, ammonia, and corrosive gas. Storage Temp.: 20 C~+60 C(but, the average temperature for 24 hours shall be lower than +35 C) Applicable current by the temperature Under the environment with over than 40, please note the rating current as follow. Rated current Ambient temperature Note) IEC Standard is applied to the data for 40 C. Bolt tightening torque(for nut) Selection of TR Capacity TR capacity should be selected more than the value calculated by the following formula. Operation Voltage x Operation Current x 0.5 = ( )VA e.g.) Operation Voltage AC 220V, Operation Current 4A 220 x 4 x 0.5 = 440VA, TR capacity of more than 440 VA is recommended. Selection of Control Relay The capacity of UVR, Operating Relay and Timer contactor should be higher than ATS operating current. Note : If the control power source is not stable, it is recommended to use Automatic Voltage Regulator. 24 I Automatic Transfer Switches

25 Automatic Transfer Switches I 25

26 Safety Manual Safety Notice This safety manual describes major informations for safe operation. Before handling this machinery, please be acquainted thoroughly with this manual. product handling, safety information and all other precautions before installation or maintenance. Emergency situation, which may cause death or serious disaster if there is mistake. A potentially problematic situation, which may cause slight personal injury and/or damage. These safety notices are devided as "Danger" and "Caution" according to the hazard level. Transportation Precaution Do not enter the area under the Automatic Transfer Switches (ATS) when it is lifted or suspended using a lifter or chain block. The ATS may suddenly drop. The ATS is heavy. Entering such an area may cause serious injury. Installation Precautions Installation should be performed by qualified persons. Prior to commencing any installation, open the upstream circuit breaker to isolate all power/voltage sources. Otherwise, electric shock may occur. Tighten terminal screws securely according to the specified torque. Otherwise, a fire may occur. Fix the Drawout type ATS firmly on a flat level using mounting screws. Otherwise, drawout operation may cause the ATS to fall. Avoid blocking of ATS's arc gas vents to ensure the adequate arc space. Blocking of the arc gas vents could result in failure of ATS. Do not place the ATS in such area of high temperature, high humidity, dusty air, corrosive gas, strong vibration and shock or other unsual conditions. Installation in such areas could cause a fire or malfunction. Be careful to prevent foreign material of debris, concrete powder, iron powder, etc and rainwater from entering into the ATS. These materials inside the ATS could cause a fire or malfunction. For 4 pole ATS, connect the neutral wire of 3phase, 4wire cable to Nphase (on the right side). 26 I Automatic Transfer Switches

27 Operation Precautions Do not touch the live terminal parts. Otherwise, electric shock may occur. Do not leave the ATS in the drawout position. The ATS is heavy. Dropping the ATS could cause serious injury. The cable size of control power should be selected considering operation current. Otherwise, a fire could occur. ATS should be operated by manual handle only under noload condition. Operation by manual handle is strictly prohibited except emergency case. Otherwise, damage to the ATS may occur. Maintenance and Inspection Precautions Maintenance, inspection or components replacement should be performed by qualified persons. Prior to commencing any work, open the upstream circuit breaker to isolate all power/voltage sources. Otherwise, electric shock may occur. Prior to commencing internal inspection for ATS, Be sure that main circuit and control source of ATS should be off. Otherwise, fingers or tools could be pinched in the internal mechanism, causing injury. Retighten the terminal screws periodically according to the specified torque. Otherwise, a fire may occur. Retighten the arcing contact mounting screws periodically according to the specified torque. Otherwise, a fire or malfunction may occur. Be sure to reinstall the arc chute if removed. Failure to do so or incorrect installation may result in a fire or cause of burns. Do not touch the live parts or structural parts close to live parts immediately after stop of power supply to ATS. Otherwise, remaining heat may cause burns. Do not approach near the arc gas vent of arc chute while ATS is under transfer. Otherwise, burns may result from high temperature of arc gas. Automatic Transfer Switches I 27

28 OSung Electric Machinery CO., LTD. Head Office & Factory : 1113, Yeoungtaeri, Wollongmyeon, Pajusi, Gyeonggido, Korea Tel : (8231) /3, (822) Fax : (8231) , (822) Website : ousung@chol.com Tel : (031) /3, (02) Fax : (031) , (02) Website : ousung@chol.com Catalog No. ATS0910

This section is specifically about safety matters

This section is specifically about safety matters 6 4 ) 5 1 5 6 4 1 -, 1 8-4 6-4 1 5 6 4 7 + 6 1 ) 7 ) 5 2 - -,, - 6 - + 6 4. 4. 2 J E? A Thank you for choosing this Mitsubishi transistorized Inverter option. This instruction manual gives handling information

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Miniature circuit-breakers S 280 UC series. System pro M. Technical data Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum

More information

Page 13-2 Page Page 13-7

Page 13-2 Page Page 13-7 Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive

More information

This section is specifically about safety matters

This section is specifically about safety matters 6 4 ) 1 6 4 1 -, 1 8-4 6-4 1 6 4 7 + 6 1 ) 7 ) 4 ) 6 1-6 6-4. 4. 0 J E? A Thank you for choosing this Mitsubishi transistorized Inverter option. This instruction manual gives handling information and precautions

More information

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) 0A PC board type 0A TM type 60A Screw terminal type 80A Connector type 300A Connector type FEATURES. High-, high-current

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE RELAYS (60A type only) A PC board type A TM type 60A Screw terminal type 80A Connector type 300A Connector type Compliance with RoHS Directive

More information

Slim compact safety relay

Slim compact safety relay Slim compact safety relay SF RELAYS Slim type Max..9 Max..9 Max.. Max..99 Max.. Max.. mm inch FEATURES Forcibly guide contact structure (EN Class A TÜV recognized) Slim profile (mm inch) Compact size with

More information

3. Contact Form A: SPST-NO

3. Contact Form A: SPST-NO 0 A Compact and high power latching relay High power switching: 0 A, 6 VAC Compact size: mm mm mm Low temperature-rise High overcurrent capability, conforming to IEC6055- UC RoHS Compliant Model Number

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion

More information

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE (60A type only) RELAYS A PC board type 80A Connector type 60A Screw terminal type A TM type 300A Connector type RoHS Directive compatibility

More information

AFC Series AFC -20HG AFC-20SE

AFC Series AFC -20HG AFC-20SE Piezoelectric Feeder Controller AFC Series AFC -20HG AFC-20SE Instruction Manual Thank you for purchasing the controller manufactured by BFC Limited. Please read this instruction manual thoroughly before

More information

20 Series Power Relays

20 Series Power Relays Power Relays 0 Technical Data... Specification... Model Number Structure - Power Relays...3 Model Number Selection... - 7 Accessories... Mounting Clips... Electrical Characteristics... Dimensions... Instructions...3

More information

REV-201М OPERATING MANUAL MULTIFUNCTIONAL TWO-CHANNEL TIME DELAY RELAY. «NOVATEK-ELECTRO» Ltd Intelligent industrial electronics

REV-201М OPERATING MANUAL MULTIFUNCTIONAL TWO-CHANNEL TIME DELAY RELAY. «NOVATEK-ELECTRO» Ltd Intelligent industrial electronics Ltd Intelligent industrial electronics MULTIFUNCTIONAL TWO-CHANNEL TIME DELAY RELAY OPERATING MANUAL Review the Operating manual before using the unit. www.novatek-electro.com Store the unit in the operating

More information

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

MINIATURE RELAY FOR WIDER APPLICATIONS

MINIATURE RELAY FOR WIDER APPLICATIONS TÜV Rheinland HJ MINIATURE RELAY FOR WIDER APPLICATIONS HJ RELAYS FEATURES contact arrangements Form C (for A 0 V AC), Form C (for 0 A 0 V AC)* Excellent contact reliability by Au plating Environmentally

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

Earth Fault Indicator EFI-BLZ-50 User Manual

Earth Fault Indicator EFI-BLZ-50 User Manual Earth Fault Indicator EFI-BLZ-50 User Manual CONTENTS SAFETY NOTICE.................................................................................... 3 1 OVERVIEW......................................................................................

More information

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax : NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)

More information

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series Specifications: Designed for installation on single wood studs or drywall (1/2" minimum thickness); either option

More information

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition

More information

TH450A-T TH550A-T THP550-T/TS3000

TH450A-T TH550A-T THP550-T/TS3000 0 TH450A-T TH550A-T THP550-T/TS3000 INSTRUCTION MANUAL CEILING TYPE (OVERHEAD TRAVELING TYPE) INDUSTRIAL ROBOT SPECIFICATIONS Notice 1. Make sure that this instruction manual is delivered to the final

More information

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type Slim type safety relays SF RELAYS Slim type RoHS compliant Protective construction: Flux-resistant type ORDERING INFORMATION S: Slim type Contact arrangement 2: 2 Form A 2 Form B 3: 3 Form A Form B 4:

More information

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External

More information

TCS2P125. Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual

TCS2P125. Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual TCS2P125 Automatic Transfer Switch Control Unit for 1 Phase System Operation Manual Single Phase 2P 125 Amp Rated Voltage 250 Vac Patent Number : U.S. Pat. No. 7,557,683 KUTAI ELECTRONICS INDUSTRY CO.,

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en Contactors Series C7, C6, C6, C65 Single pole contactors for battery voltages Catalogue B.en Contactors for battery voltages C7, C6, C6, C65 Series With its proven line of C7 through C65 Series contactors

More information

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY EV RELAYS (AEV) 80A A 0A FEATURES. High-, high-current control possible 0 high- switching cutoff has been achieved thanks to a sealed construction

More information

SLIM COMPACT SAFETY RELAY

SLIM COMPACT SAFETY RELAY SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile

More information

Brake Unit. Contents. Brake Unit Overview Product information C-26 C-27

Brake Unit. Contents. Brake Unit Overview Product information C-26 C-27 Contents Overview Product information C- C- This product is for industrial equipment. Don't use this product at general household. industrial.panasonic.com/ac/e/ C- Overview Outline of These s are electric

More information

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC

Type Poles Contact configuration Rated voltage Model G7S-4A2B 24 VDC 3PST-NO, 3PST-NC Relays with Forcibly Guided Contacts G7S CSM_G7S_DS_E_5_ Relays Conforming to EN Standard Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery

More information

High Capacity of Max. 1,000 V DC Cut-off Possible

High Capacity of Max. 1,000 V DC Cut-off Possible EP (A (AEP) and 80A types) High Capacity of Max.,000 V DC Cut-off Possible EP RELAYS (AEP) A PC board type A TM type New A TM type 80A type 300A type Compliance with RoHS Directive FEATURES. High-, high-current

More information

Model:CB-MRC. Instruction Manual of Mini Recessed Motorized Screen

Model:CB-MRC. Instruction Manual of Mini Recessed Motorized Screen GRANDVIEW REPRODUCING GENUINE COLORS GRANDVIEW REPRODUCING GENUINE COLORS Instruction Manual of Mini Recessed Motorized Screen Grandview Crystal Screen Canada Ltd. #11-3751 North Fraser Way, Marine Way

More information

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control Caution: Device contains unprotected active pieceparts, Device contains unprotected non-active pieceparts, which may interact with active pieceparts, Touch only after adhering to corresponding safety regulations!

More information

Computer-14d - xx - 144a

Computer-14d - xx - 144a POWER FACTOR REGULATOR Computer-14d - xx - 144a INSTRUCTION MANUAL ( M 981 602 / 98B ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14d --------- Page 2 1.- POWER FACTOR REGULATORS COMPUTER-14d-144a

More information

Installation Instructions

Installation Instructions TECH SUPPORT The Watt Stopper, Inc. 2800 De La Cruz Blvd. Santa Clara, CA 95050, USA Tel: 1(800)879-8585 1(972)578-1699 Fax: 1(972)422-1311 www.wattstopper.com Outdoor 180 & 270 PIR Motion s Model#s: EW-100-120

More information

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC

Type Poles Contact configuration Rated voltage Model 3PST-NO, 3PST-NC 24 VDC Relays with Forcibly Guided Contacts G7S-@-E CSM_G7S-_-E_DS_E_3_ Lineup Now Includes -A Models Relays with forcibly guided contacts (EN525 Class A, certified by VDE). Supports the CE marking of machinery

More information

DLP-PU/EJ Instruction Manual

DLP-PU/EJ Instruction Manual DENSEI-LMD Instruction Manual EORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or

More information

CSM_G7S-_-E_DS_E_7_1

CSM_G7S-_-E_DS_E_7_1 Relays with Forcibly Guided Contacts G7S-@-E CSM_G7S-_-E_DS_E_7_ Relays with Forcibly Guided Contacts and High Switching Capacity of A Relays with forcibly guided contacts (EN525 Class A, certified by

More information

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series

INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series INSTALLATION INSTRUCTIONS SMALL FLAT PANEL ADJUSTABLE PITCH WALL MOUNT Model: FTR Series Specifications: Designed for installation on single wood studs or drywall (1/2" minimum thickness); either option

More information

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

High Reliability Of Fiber Optic Amplifier For Convenient Mounting Amplifier Reliability Of Amplifier For Convenient Mounting Features speed response: Max. 0.5ms Auto (Button setting)/remote synchronization input, mutual interference protection, selfdiagnosis Reverse

More information

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA

More information

Instruction Manual for Digital Grounding Resistance Meter

Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Instruction Manual for Digital Grounding Resistance Meter Table of Contents I. Overview...2 II. Open-case Inspection...3 III. Safety Precautions...4

More information

Sendai Office , Ichiban-cho, Aoba-ku, Sendai, Miyagi pref TEL FAX

Sendai Office , Ichiban-cho, Aoba-ku, Sendai, Miyagi pref TEL FAX FS Operations Dept. 8-122, Kiba-cho, Minato-ku, Nagoya, Aichi pref. 455-0021 Minato Plant TEL +81 52-691-1828 FAX +81 52-692-1915 Sendai Office 1-10-32, Ichiban-cho, Aoba-ku, Sendai, Miyagi pref. 980-0811

More information

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager.

Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. Request Ensure that this Instruction Manual is delivered to the end users and the maintenance manager. 1 -C - Safety section - This Safety section should be read before starting any work on the relay.

More information

Installation Instructions

Installation Instructions Installation Instructions Ceiling Mount Bracket for DLP Based Projectors (for High Ceilings) Model No. ET-PKD100H Contents Important Safety Notice.................. 2 For DLP Based Projector: PT-D10000

More information

page 2 of 86 Report reference No:

page 2 of 86 Report reference No: articulars: test item vs. test requirements 3. Classification 3.1. Utilization category: (A or B)... : A 3.2. Interruption medium: (air, vacuum, gas Break)... : Air 3.3. Design: (open construction, moulded

More information

Part No. Z , IB Operation Manual. Pseudo Voice Generator KSG3600

Part No. Z , IB Operation Manual. Pseudo Voice Generator KSG3600 Part No. Z1-003-990, IB011375. 2014 Operation Manual Pseudo Voice Generator KSG3600 Use of Operation Manual Please read through and understand this Operation Manual before operating the product. After

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C Touch Switch CSM DS_E 3 Unique 18-mm-dia. Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Only a slight activation force is required, enabling

More information

Operation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD No.PAN E-01.

Operation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD   No.PAN E-01. Operation Manual SWF Series Switch Mode Power Supply 1 Table of Contents Safety Precautions 3 Appearance and Meaning of Safety Warnings 4 Hazard and Caution Safety Warnings 4 Introduction to SWF Series

More information

INTERPLANT STANDARD - STEEL INDUSTRY

INTERPLANT STANDARD - STEEL INDUSTRY INTERPLANT STANDARD - STEEL INDUSTRY SPECIFICATION FOR MOULDED - CASE CIRCUIT-BREAKER FOR VOLTAGES NOT EXCEEDING 1000 V ac OR 1500 V dc (FIRST REVISION) IPSS:1-04-004-11 IPSS BASED ON IS/IEC 60947(Part

More information

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation General Purpose Relays MKS Exceptionally Reliable General Purpose Relay now available with Lockable Test Button IEC Rating of A 0 V AC 0/0 Hz, General use 100,000 cycles. Mechanical indicator standard

More information

Multiple Program Process Temperature Controller. Installation Guide Maxitrol Company, All Rights Reserved

Multiple Program Process Temperature Controller. Installation Guide Maxitrol Company, All Rights Reserved + Multiple Program Process Temperature Controller Installation Guide www.maxitrol.com Warnings Inappropriate and/or improper installation, adjustment, alteration, service or maintenance can cause property

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

INSTALLATION INSTRUCTIONS POLE/PITCH- ADJUSTABLE MOUNT Model: TPM-2000 SERIES

INSTALLATION INSTRUCTIONS POLE/PITCH- ADJUSTABLE MOUNT Model: TPM-2000 SERIES INSTALLATION INSTRUCTIONS POLE/PITCH- ADJUSTABLE MOUNT Model: TPM-2000 SERIES Specifications: Weight capacity of 150 lbs. (68 kg). Provides tilt range from 5 up to 15 down. Accommodates vertical pole (1"

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples. Miniature High Capacity Relays with SPST-NO 0A and SPST-NO + SPST-NC A SPST-NO 0A and SPST-NO + SPST-NC A for power switching and output that satisfy the needs for space-saving. Small High-capacity Relays

More information

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No. RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in

More information

30 AMP POWER RELAY WITH SPACE SAVING DESIGN

30 AMP POWER RELAY WITH SPACE SAVING DESIGN VDE 3 AMP POWER RELAY WITH SPACE SAVING DESIGN JH-RELAYS 2..2 3.. FEATURES Many safety-oriented characteristics incorporated Contact gap: more than 3 mm. inch for Form A and 2 Form A Breakdown voltage

More information

COMPONENTS. Power contactor Type BMS09.08 / BMS18.08

COMPONENTS. Power contactor Type BMS09.08 / BMS18.08 COMPONENTS Power contactor Type 09.08 / 18.08 Type A (V AC General information The contactor, with more than hundred thousands units in operation worldwide, has always been a contactor valued by the car

More information

Installation Manual. Arc Chamber

Installation Manual. Arc Chamber Installation Manual Arc Chamber Installation Manual Introduction Administrative data Issue number: 6082940 G01 01 Date of issue: 25-03-2013 2 Arc Chamber Installation Manual 6082940 G01 01 March 25th 2013

More information

Maintenance instructions

Maintenance instructions Maintenance instructions for trained personnel, certified by Woodward (Exemplary illustration) - Circuit breaker 1733-1258 / KP-48327 Document no.: 9943-1799 Revision: B EN GB Original operation manual

More information

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model

Type Sealing Poles Contact configuration Rated voltage Model. Type LED indicator Poles Rated voltage Model Relays with Forcibly Guided Contacts CSM DS_E_6_ Compact, Slim Relays Conforming to EN Standards Relays with forcibly guided contacts (EN50205 Class A, certified by VDE). Supports the CE marking of machinery

More information

TV-15, 30 AMP (1 Form A) Power Relay

TV-15, 30 AMP (1 Form A) Power Relay VDE TV-, 3 AMP ( Form A) Power Relay RELAYS Form A Plug-in type Form A type also available with 48A contact capacity FEATURES. Excellent resistance to contact welding Owing to the pre-tension and kick-off

More information

C-Bus 8 Channel Low Voltage Relay

C-Bus 8 Channel Low Voltage Relay SLC5108RELVP Instruction Bulletin Retain for future use. 63249-420-325A1 Instruction Bulletin 07/2009 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment to

More information

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2

More information

R4850G1 Rectifier User Manual V1.3

R4850G1 Rectifier User Manual V1.3 Environmental s Efficiency The peak point is 96%; 95%(230V AC,20% 90% load) Item Operating temperature Storage temperature Relative humidity Altitude range -40 C to +75 C (referring to Figure 3) -40 C

More information

SM6. installation instructions. internal arc 16kA. 1s. addition to the standard cell user s instructions

SM6. installation instructions. internal arc 16kA. 1s. addition to the standard cell user s instructions SM6 Anglais MV distribution factory built assemblies at your service installation instructions internal arc 16kA. 1s addition to the standard cell user s instructions foreword... 3 symbols and conventions...

More information

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC Datasheet NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO 13849-1 EN 62061 EN 81-1 EN 50156-1 Approvals NSD-3580 24 VDC NSD-3590 115 TO 230 VAC Technical

More information

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC

RE7MY13MW time delay relay 8 functions s V AC DC - 2OC Characteristics time delay relay 8 functions - 0.05..1 s - 240 V AC DC - 2OC Main Range of product Product or component type Contacts type and composition Component name Time delay type Time delay range

More information

NDQ Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

NDQ Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD Shanghai Liangxin Electrical CO.,LTD Address: No. 668 Heng An Road, Pu Dong New District, Shanghai Zip: 200137 Tel: 8621504789 Fax: 862158675966 Email: client@shliangxin.com 2010 Shanghai Electrical All

More information

Operating Instruction

Operating Instruction Level and Pressure Operating Instruction VEGASEL 643 6 5 + + 3 5 + + max. min. on VEGASEL 643 5 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 1 Product description 1.1 Function

More information

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage

Type Sealing Poles Contacts Rated voltage Model Standard Flux-tight 4 poles 3PST-NO, SPST-NC 24 VDC G7SA-3A1B. Type LED indicator Poles Rated voltage Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,

More information

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range GT3A Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEDs UL,

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US ---

Standard model G2A-432A-US G2A-4321P-US. Arc barrier equipped model G2A-432AY-US --- Power Relay G2A Highly Reliable, 4-pole Miniature Relay Ideal for Sequence Control Card lift-off employed for greater life and stable quality. Long endurance and stable quality are assured by card lift-off

More information

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable: Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.

More information

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents I. Overview...2 II. Open-case Inspection...3 III. Safety Precautions...4 IV. Work Principle...7 V. Appearance Description...9 VI. Technical Characteristics 10 VII. Resistance Measurement Method..12 VIII.Battery

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Sheet 1 of 5 General: Upon receipt of fixture thoroughly inspect for any freight damage, which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the

More information

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure General-purpose Relays MK-S (New Models) CSM_MK-S_DS_E 1 New Super MK Relays. Latching Lever Added to the Series. Same mounting and internal wiring as the previous Super MK Relays Built-in mechanical indicator

More information

Distributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility

More information

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts) IDEC RJ22 Series Slim Relays (Bifurcated Contacts) Phone: 00.94.042 - Fax:.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com RJ Series Slim Relay Plug-in Terminal (Bifurcated Contacts) High contact

More information

SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES AS540 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A054N491 (Issue 1) Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS...

More information

Operating instructions Fail-safe delay timer AZS About this document. Content

Operating instructions Fail-safe delay timer AZS About this document. Content 8 Appendix 8.1 Wiring example...4 8.2 Integral System Diagnostics (ISD)....5 9 EU Declaration of conformity Operating instructions.............pages 1 to 6 Original x.000 / 11.2017 / v.a. - 101126753-

More information