Time Switches. Because we have a Responsibility

Size: px
Start display at page:

Download "Time Switches. Because we have a Responsibility"

Transcription

1 TIME SWITCHES

2 Time Switches On 8th August 1958, a young entrepreneur manufactured, India's first indigenously developed, sheet steel enclosed rewirable switch at Jalandhar in Punjab, marking the birth of Indo Asian. Nearly Half a century later, Indo Asian has a proven track record of manufacturing and marketing a wide range of high quality electrical control & protection products, which include electrical safety devices such as Indo Kopp MCBs, Stopshock RCCBs, HRC Fuselinks, Indo Asian Wires & Cables, Insulated Industrial Plugs & Sockets, Hausmann Modular Wiring Accessories and of course ecofriendly energy saving Compact Fluorescent Lamps. Because we have a Responsibility Indo Asian's product portfolio reflects its philosophy of social responsibility. At Indo Asian, on one hand we manufacture devices which make the use of electricity safe & convenient, on the other hand, ecofriendly energy saving Compact Fluoresent Lamps conserve scarce electrical power. Indo Asian has installed the largest integrated and automated CFL manufacturing setup in south East Asia to produce a wide range of Smart Compact Fluorescent Lamps which are used in homes, offices, hotels, entertainment arenas, shopping arcades, public areas, housing colonies etc. enabling these users to conserve nearly 80% electrical energy conventionally used for lighting. Thus addressing a crucial need of the nation. The Technology Edge The group's pursuit of excellence backed by extensive inhouse R&D, technical and commercial collaborations with world's best renowned companies such as Heinrich Kopp AG, Doepke & Co. AG., and Theben AG Werke Zeitautamatic GmbH, all from Germany and ETI Elektorelement d.d. of Slovenia of all have resulted in bringing world class products from all the 5 modern and state-of-the art manufacturing units of Sonepat, Jalandhar, Noida and Parwanoo.

3 Time Switches Theben The abilities of Theben AG lies in solutions for time, lighting and climate control. Within time switching devices, modules or bussystems, Theben produces the highest quality products in every range. Theben offers not only time switches in analog and digital technology with classical switch tappets or segments, but also microprocessor-controlled digital devices that offer hours, days, weeks and years programs and an extensive program of sensors and actuators for the EIB bus technology. On top of this Theben is well known for its stair, light and twillight switches and for its clock thermostats that allow a power saving heating control. Theben offers its clients a tailored solution for all applications and situations. Theben AG manufacturing plants in Germany, Great Britain, France, Italy and Switzerland and is one of the leading producers of time switching devices and systems. A worldwide presence in more than 54 countries with market leading high-quality products form the basis for continual growth. Theben products are very well-known for their user-firendly operation, a high product quality and a first rate design. In India the complete range of Theben products are made available from "Indoasian Fusegear Ltd. The company is certified according to the international DIN ISO 9001 standardisation. The Philosophy We are an autonomous, independent, internationally operation company with a high potential of innovation and a great many profitable ideas and concepts for the future. Our core competency encompasses the control and regulation of time, light and climate. We are recognized specialists, especially when it comes to timer devices and other intelligent systems. Our goals are innovation, high functionality, best quality, dependability, continuity and calculability. We are a dependable and competent partner to our customers, offering competitive products and services. The Theben company aims to serve, and continuously supports the personal as well as the occupational qualification and development of its staff members.

4 Analog Time Switches SUL-189 s Segment Time Switch Function : Time switches with or without power reserve. 24 hour dial with segment of 15 min. Switching time each. Early ON/OFF over-ride switching without influencing the subsequent program sequence. Permanent ON/OFF switching, e.g. for holidays. Changeover contact 10A/250V~. Switching status indication. Clock hands can be reset for switching over between summer/winter time. Technical Data : Nominal voltage : 230 V ~±10% Power Consumption : Max. 2.5 VA. Permissible ambient temperature : -10ºC..+50ºC Time setting : analog with clock hands, also possible anticlockwise. Contact : Floating, gap less than 3 mm (µ). Contact material : Hard silver, gold-plated. Switching Capacity : 10A/250 V ~, cos =1 2A/250 V ~, cos =0.6. Housing and insulating material : high temperature-resistant, fireproof thermoplastics. Electrical Connection : screw terminal or 4.8 mm tab connectors. Protection class : II in accordance with EN if installed as directed. Quartz time switch with power reserve Drive : quartzcontrolled stepping motor. Mains frequency : Hz. Accuracy : ± 1 Sec./day at 20ºC. Power reserve : Approx. 72 hours on fully charge battery at 20ºC Full power reserve : approx. 3 days after connection to operating voltage. Weight : Approx. 260g. Design : Front frame 72 x 72 mm Switch panel mounting with clip fastening. Connection either with tab connectors (4.8mm) or with screw terminals using the plug-in base. Surface mounting with plug-in base and terminal cover. Can also be mounted on a 35 mm top-hat rail with additional parts or on PC boards with plug connector. Transparent cover protects against dirt and unintentional adjustment Type Program Power reserve Switching Programmable Minimum Switching Nominal Order No. dial approx. segments every... switching interval contacts current at 250~ SUL 189 s 24 hours 3 days min. 15 min. 1Changeover Switch 10 (2) A T

5 Analog Time Switches SUL 181 h Segment Time Switch Function : Time switches with power reserve. 24 hour dial with 30 min. segments or 60 min dial with 75s segments. Early manual over-ride switching for on and off without influencing the subsequent program sequence. Permanent ON/OFF switch. Switching status indication. Fine adjustment for time setting accurate to the minute. Summer/winter time correction ± 1 hour by the bi-directional fine time adjustment facility. Operating indication. TECHNICAL DATA : Nominal voltage : 230V ~ ± 10% Permissible ambient temperature : - 20ºC ºC. Power Consumption : Max. 2.5 VA. Contact : Floating, gap less than 3 mm (µ). Contact material : Hard silver. Housing and insulating material: High temperature-resistant, fireproof thermoplastics. Enclosure type : IP 20 in accordance with EN Protection class : II in accordance with EN if installed as directed. Test Approvals : national and international depending on device type. Quartz time switches with power reserve : Drive : quartz-controlled stepping motor. Mains frequency : Hz. Accuracy : = ± 1 sec./day at 20ºC. Power reserve : upto 72hours on fully charged battery. Weight : approx. 150g. DESIGN : Standard housing 45x54x60(mm). Snap-on fixing for 35mm top-hat rail (DIN EN 50022). Surface-mounting with additional terminal cover, tamper proofing. Tamper proof operating panel protects against undesired programming interventions. Shock protection in accordance with accident prevention regulation VBG 4. Captive terminal screws * * L N M ~ Type Program Power reserve Switching Programmable Minimum Switching Nominal Order No. dial approx. segments every... switching interval contacts current at 250~ SUL 181 h 24 hours 3 d min. 30min. 1 Changeover 16 (4)A T Switch

6 Analog Time Switches SUL 180 a Segment Time Switch Function : Time switches with 24 h or 7 day segment dial. Programming by 15 minutes segments in the day program. Programming by 2 hours segments in the week program. Technical Data : Nominal voltage : 230V ~ ± 10% Frequency : Hz Power Consumption : Approx. 2, 5VA Contact : Floating, gap less than 3 mm (µ). Contact material : Ag Cd O Permanent ON/OFF switch. Normally open contact 16A/250V~ Switching status indication Switching Capacity : 16A 250 V ~, cos =1 4A, 250 V ~, cos =0.6. Accuracy : = ± 1 sec. /day at 20ºC. Power reserve : approx. 3 days at 20ºC Permissible ambient temperature : -10ºC...+50ºC Housing and insulating material : high temperature-resistant, fireproof thermoplastic. Test approvals : national and international depending on device type. Protection class : II in accordance with EN if installed as directed. Weight : approx. 120 g. Design : Standard housing 45 x 17,5 x 60 (mm) Snap-on fixing for 35 mm top-hat rail (EN 50022) Tamper proof transparent cover protects against undesired programming interventions. Shock protection in accordance with accident prevention regulation VBG 4. Captive terminal screws * * 55.5* L N M ~ Type Program Power reserve Switching Programmable Minimum Switching Nominal Order No. dial approx. segments every... switching interval contacts current at 250~ SUL 180a 24 hours 3 d 96 1/4 hour 1/4 hour 1 Working 16(4)A T Contract

7 Motion Detector LU Motion Detector Function : Technical Data : Detection angle : 180º Motion detector for mounting on exterior house wall or corner. Distance : 14 m max. depending on the adjustment of the sensor, on the surrounding temperature and on the direction of approach. Detector functioning by passive infrared technology. Reacts to the temperature variations resulting from moving bodies, cars etc. For increased safety and convenience around the home. Automatic switch-on off connected lighting when detection area is entered and delayed switch-off when area is left. Switching capacity : 10A/230 V~. Incandescent lamps : upto 2400 W. Halogen lamps : upto 2400 W. Fluorescent lamps : upto 500 W. Dimensions : 68 x 68 x 122 mm Suitable for controlling lighting in house and garage entrances, hall, stairs, garden, storage rooms etc. Energy saving because the lamps automatically switch off after a predetermined time (adjustable timing). Integral photoelectric cell preventing switching on during daylight. Timing is restarted every time a motion is detected. Quick installation and adjustment. White housing. L N LS 180º L N Type Detection Mounting Brightness Time Range Switching contacts Nominal Current Angle Height Range LU º Min 2m lux 5 sec...12 min. 10A, 230 V~ Max 14m. Caution : the detection range and quality depends on ambient temperature and the axis in which the movement takes place in relation to the product. The range is greater when the movement is across the field of view of the sensor rather than directly towards it.

8 Digital Time Switches Digital Timers Switch TR 610 Top / TP 612 Top/TR 611 Top By means of text-oriented operator guidance you are escorted step by step through the entire programming. Function : Technical specifications : Rated voltage : V~+6%-10% Frequency : 50-60Hz Own consumption : max. 6 VA Day/Week Program Contact : zero-potential, break gap less than 3 mm ( ) TR 610 Top TR 608 Top Operator guidance by an integrated LCD display Programming is shown graphically by a means of a bar chart on the LCD display Preset ex-works-time (CET) and automatic summer/winter time changeover Summer/Winter time changeover can be alternatively switched off or randomly programmed (GB, USA changeover norm selectable) High number of memory locations Guided copying of the switching times to other days of the week (random block formation) Sorting of the switching times in memory by the day of the week Switching preselection Permanent switching Lithium battery and EEPROM TR 622 top TERMINA 2 channels with 42 memory locations Holiday switching, random function and pulse program separate for each channel. Cycle program for channel 1. Contact material : Ag Sn O 2 Switching power : 16A, 250V~, cos =1; 10A, 250V~, cos =0.6. Incandescent lamp load : 2300W Halogen lamp load : 2300W Fluorescent lamps : non compensated, series comp. 1000W, parallel comp. 400 W (42f) Compact fluorescent lamps : 9x7 W, 7x11W, 7x15w, 7x20W, 7x23W Timing basis : quartz Working precision : <± 1 sec./day at 20ºC Shortest switching time : 1 minute (pulse/cycle 1 sec.) Switching precision : exact to the second Display : LCD display with text line Operating control elements : 4 touch keys and 1 reset key Power reserve : approx. 4 years with display with full controllability (temp. 20ºC) by means of an environmentally friendly lithium battery Permissible ambient temperature : -10ºC...+50ºC Enclosure and insulating material : high-temperature resistant, self-extinguishing thermoplastics Protection class : II in compliance with EN if installed as directed Degree of protection : IP 20 in compliance with EN Test approval : Weight : appox. 170 g Design : Standard enclosure 45 x (mm) Quick fastening facility for 35 mm DIN rail (EN ) Built-on installation with an additional terminal cover which can be fitted with a leadable seal Switch panel installation complete with installation kit No Captive hinged cover which can be fitted with a leadable seal.

9 Digital Time Switches Overview of the menu levels TR 611/622 top TR 610/612 top * only TR 611/622 top * only TR 622 top Type Program Memory Power reserve Programmable LCD Switch Rated Current Ordering No. Location (Lithium) every... backlit Contacts at 259V~ TR 608 top 24h 28 3 years 1 min - 1 changeover 16(6)A T channel 7d switch TR 610 top 24h years 1min. - 1 changeover 16(10)A T channel 7 days Switch TR 612 top 24h/7 days years 1 min. - 2 changeover 16(10)A T channel 7random days switches switching, holiday TR 611 top years 1 min. yes 1 changeover 1 channel program, switch 16(10)A T pulse and cycle TR 622 top years 1 min. yes 2 changeover 16(10)A T program 2 channels switches Terminal cover for built-on installation, can be fitted with a leaded seal

10 Analog Time Switches SEL 170 top Selekta Technical data : Function : Nominal voltage : V, +10%/-15% Solar 1-channel weekly clock with top operating philosophy, i.e. simplest possible operation through text-oriented programming Frequency : 50-60Hz Power consumption : max, 6VA Precise calculation of sunrise and sunset times through inputting date, time and location coordinates (longitude and latitude) Power reserve : approx. 10 years at full operability (temp. 20ºC) through pro-environmental lithium cell SEL 170 Top Alternatively, the location coordinates can be specified via a country-specific and preprogrammed list of cities. The switching on and off of the connected consumer depends on the sunrise and sunset times and can be offset forwards or backwards for fine adjustment by up to 120 minutes Contact : Floating changeover contact Gap : less than 3 mm ( ) Contact material : Ag Sn O2 Resistive switching capacity : 16A, 250V, cos =1 Factory-set date and time Text-based programming in 4 easy steps, supported by self-explanatory symbols. Energy-saving night switch-off with simple programmable weekly program Inductive switching capacity : 10A, 250V, cos =0.6 Incandescent lamp load : 2300 W Halogen lamp load : 2300 W Semi-automatic function (e.g. light on during evenings, night switch-off at 2300 hrs) Uncorrected fluorescent lamp : 1000VA Guided copying of switching times to other weekdays (block formation). The daily switching times are graphically illustrated by a segment bar in the LCD Date-controlled holiday program Continuous Switching (continuous on or continuous off) Series corrected fluorescent lamps : 1000VA Parallel-corrected fluorescent lamps : 400VA(42 f) Lead-lag (duo) fluorescent lamps : 1000VA Uncorrected mercury discharge lamp : 4 x 125W, 2x250W, 1 x 400W, 1x700W switching pre selection An external input S enables the output to be switched via a control signal (e.g. manual switch) Parallel-corrected mercury discharge lamp : 6x50W (7f), 4x125W (10f), 2x 250W (18f), 1x400W (25f), 1x700 W (40f). Uncorrected sodium discharge lamp : 2x250W, 1 x 400 W In code, 10 year power reserve Automatic summer/winter time correction, can be disabled or freely selected (Europe, GB, USA/CAN changeover rule also selectable) Flexible alternative to twilight switch (brightness sensor does not need to be wired) Parallel compensated sodium discharge lamp : 2x250W (20f), 1x250W (32f), 1x400W (45f) Compact fluorescent lamps : (Capacitive ballast) 1000 VA, (Electronic ballast) 9 x 7W, 7X11W, 7x15W, 7x20W, 7x23W Time based on : Quartz Switching time guaranteed through EEPROM Time accuracy : <± 1s/day at 20ºC Shortest switching time : 1 minute Switching accuracy : to the second Display : LCD with text line Control elements : 4 touch control key s and 1 reset key Permitted ambient temperature : -10ºC...+50ºC Protection rating : IP 20 to En Protection class : II to EN for designated installation Weight : approx. 170g

11 Analog Time Switches SELEKTA 170 top-solar Timer The SELEKTA 170 top, Theben's 35mm wide astronomic timer is an ingeniously simple to operate control unit based on the established TERMINA top operating concept. The special features of an astronomic timer are the precisely calculated sunrise and sunset imes. This ability to calculate switching times so precisely makes the SELEKTA 170 top the ideal solution for illuminating roads, squares, courtyard approahces, display windows and corporate logos. Design Standard housing 45x35x60 mm to DIN Quick fastening for 35mm profile rail (DIN EN ) Contact protection to comply with accident prevention regulation BVGA2 (VBG 4) Top mounting with additional terminal box cover plate, sealable (No ) Control panel installation with assembly kit (No ) Captive cover flap, sealable Lighting control system with SELEKTA 170 top Lux (brightness) Calculated time for sunrise and/or sunset (Astro Time) Sunset Sunrise Individually programmed times for night switching Night switch-off Type Program Power reserve Programmable Special Switching Nominal Order No. (Lithium) every... Function Contacts Voltage at 250 V~ SEL 170 top Astro program 10 Years 1 minute Local 1 changeover 16(10)A T Weekly program database switch Terminal box cover plate for top mounting, sealable SEL 173 DCF Astronomical year 1.5 years 1 minute Holiday or weekend 2 changeover 16(10) A T programm, 24h/7 days/years switching channel change switch (without antenna and power unit) Antenna for DCF77 radio signal, makes DCF77 time synchronisation possible. Power supply is integrated in the device. T Programming set OBELISK (chip card, intermediate plug for PC interface, Software) T OBELISK memory board (separately) T

12 Twilight Switches LUNA LU Star Series LUNA Functions : Technical Data : Nominal voltage : 230~, ±10% Twilight switch in a modern, innovative design Integral light sensor with a very large light-entry angle (approx. 180º) and specially formed lens Immediate LED display of switching status Variable ON/OFF delay settings of approx s, LUNA 129 star-time: 0-180s, LUNA 126 star: 40s fixed setting Test button for checking the installation, independent of brightness setting (except LUNA 126 star) Infinitely variable brightness range of approx lux (model dependent). Preset brightness value of approx. 15 lux as delivered (LUNA 127 star and LUNA 129 star-time) High quality relay ensures safe, secure switching of lamp loads. Frequency : 50Hz Power consumption : Approx. 3.5 VA, 2 VA(LUNA 129) Contact : not floating, gap less than 3 mm ( ) Contact material : Ag Sn O2 Switching capacity : 16A/230V~, cos =1, 10A/230V~, cos =0.6 LUNA 126 star : 10A/230V~, cos =1 6A/230V~, cos =0.6 Glow lamp load : 2300W (LUNA 126 star : 1000W) Halogen lamp load : 2300W (LUNA 126 star : 1000W) Fluorescent lamps : Uncorrected/series-corrected : 2300VA (LUNA 126 star: 1000VA) Parallel-corrected : 400 VA(42f) (LUNA 126 star; 120 VA(18f) Lead-lag circuit (duo) : 1200VA (LUNA 126 star: 400VA) Mercury vapor lamps : Uncorrected/series-corrected : 1000VA Parallel-corrected : 250VA(40f) (LUNA 126 star: use contactor) Sodium vapor lamps : Uncorrected/series-corrected: 1000VA Parallel-corected : 250VA(37f) (LUNA 126 star: use contactor) Compact flourescent lamps : (Capacitive ballast) 1500 VA (Electronic ballast) 9 x 7 w, 7x11w, 7x15w, 7x20w, 7x23w (LUNA 126 star: (capacitive ballast) 400 VA (Electronic ballast) 4x7W, 3x11W, 3x15W, 3x20W, 3x23W) Light intensity setting : depends on model, see table Switch delay time : depends on model, see table Permissible ambient temperature : -35ºC to +55ºC Protection class: II, when installed in accordance with EN and EN Degree of protection : IP 55 (in accordance with EN 60529), with bottom connection

13 Twilight Switches LUNA Design Generous terminal space for connecting and extending wiring as needed 5 connecting terminals including an extra (PE) terminal (except LUNA 126 star) Compact and unobtrusive housing for exterior installation Splash-proof housing (IP 55) Mast installation possible with standard tubing clamp (no included) Cables can be connected at the bottom or back of device housing (2cables possible) Quick-clamping screws for securing the hinged housing cover 4mm2 connection cross section Housing colour: white Type Brightness Installation Switching delay Switching Nominal Order No. range ON/OFF contacts Current at230 v~ LUNA 126 star Lux infinitely Wall mount or approx. 40 s (fixed) 1 Working contact 10 (6)A T adjustable (linear) mast mount LUNA 127 star Lux infinitely Wall mount or s 1 Working contact 16 (10) A T adjustable (linear) mast mount infinitely adjustable LUNA 128 star Lux infinitely Wall mount or s 1 Working contact 16 (10) A T adjustable (logarithmisch) mast mount infinitely adjustable LUNA 129 star Lux infinitely Wall mount or 0-10 min Working contact 16 (10) A T star-time digital adjustable mast mount digital adjustable

14 Twilight Switches LUNA LU 110 Luna LU 112 Luna Twilight switch for distribution panel installation with separate surface-mounted or built-in light sensor. Switching brightness can be adjusted continuously between approx lux with the adjusting screw immediate indication of the switching status by LED Approx.40 s switch- ON/swiitch-OFFdelay in order to avoid switching errors owing to lightning flashes or car headlamps etc. Twilight switch for distribution panel installation with separate light sensor as above, but: Control unit with range selector switch for 2 brightness ranges: Range 1: approx lux Range 2: approx lux Approx. 40/80s switch-on/switch-off delay in order to avoid switching errors owing to lightning flashes or car headlamps etc. Technical data: Nominal voltage: 230 V~, ±10 % Mains frequency: Hz Power consumption: approx. 2.2 VA LU 113 approx. 2.7 VA Contact: floating, gap less than 3 mm ( ) Contact: material:ag Sn O2 Switching capacity : 10A/250 v~, cos = 1 6A/250 v~, cos = 0.6 incandescent lamp load: 1000 w Halogen lamps: 1000 W (230 V~) Fluorescent lamp: uncompensated/series compensated 800 W parallel compensated 200 W lead-lag circuit (duo) 800 W High-pressure discharge lamps : use power contactor Brightness range : lux on LU lux, lux on LU 110 Switching delay (ON/OFF) : Approx. 80s, Approx. 40s on LU 110 and LU 113 Switching status indication : LED (no delay) Connection cable for light sensor : 2-core cable max. 100m Permissible ambient temperature : control unit : -10ºC...+50ºC light sensor : -40ºC...+70ºC Protection class : II in accordance with EN if installed as directed Degree of protection : in accordance with EN Control unit : IP 20 Surface-mounted light sensor : IP 54 with cable connection at bottom built-in light sensor : IP 65 Test approvals : national and international depending on device type Type Brightness Adjustment Sensor Switching delay Switching Nominal Order No. range ON/OFF contacts current at 250V~ LUNA Lux 1 brightness Surface-mounted 40/40s 1 changeover 10 (6) A range light sensor (IP 54) switch with screw terminals LUNA Lux 1 brightness Built-in light sensor 40/40s 1 changeover 10 (6) A range (IP 65) with 1.5 m cable switch Terminal cover for surface mounting LUNA 110, tamper proofing LUNA Lux 2 brightness Surface-mounted 80/80s 1 changeover 10 (6) A ranges light sensor (IP-54) switch with screw terminals LUNA Lux 2 brightness Built-in light sensor 80/80s 1 changeover 10 (6) A ranges (IP 54) with 1.5m cable switch Terminal cover for surface mounting LUNA 112, plombierbar LUNA Lux 2 brightness Surface-mounted 40/40s 2 changeover 10 (6) A ranges light sensor (IP-54) switch 2 channels with screw terminals max. 10 devices attachable Terminal cover for surface mounting LUNA 113. Built-in light sensor, connection cable 1.5m, Degree of protection IP 65 (spare part), (except LUNA 113) Surface-mounted light sensor with fastening square and screw terminals, (except LUNA 113) Surface-mounted light sensor with fastening square and screw terminals, (only for LUNA 113)

15 Din Rail Programable Logic Controller Din Rail Program Programmable Logic Controller PHARAO-II 14 (AC) Common Functions Programmable controller for commercial and industrial use. 34 pre-programmed function blocks with special control functions that can be used up to 200 times Direct programming of even complex Boolean functions in one function module Programming, editing and modifying on the unit itself via 8 keys without interface cable Backlit LCD with operator guidance in 4x12 character text Input and output switching status display Process variable display (MMI function) Assignment of programmed functions on front key Internal EEPROM memory for max. 200 function blocks (5,000 bytes) Optional plug-in EEPROM for program transfer or dual programming of internal/plugged-in EEPROM 3-level password protection Realtime year clock with 1,000 switching times Graphical programming software for windows 95/98/NT/2000/ME/XP with detailed online help documentation Programming of the function blocks via "drag and drop" Online/offline program simulation on screen Remote control/remote monitoring possible via modem or GSM modem Transmission of SMS, or fax Communication in all directions Communication in all directions Analogue modem Cost efficient remote control and monitoring. Because PHARAO software 2.0 contains the entire set of communication tools, the PC requires only a modem to enable remote configuration, monitoring and programming. GSM Modem Error messages or threshold values in te text can be sent from controller to Fax Machine. Error messages or threshold values in the text can be sent by SMS from controller to mobile telephone. Type Outputs Rated Voltage Range Inputs Input Frequency Order No. PARAO 6 (AC) 2 relays (NO Contact) VAC, +10%/-15%, 4 digital inputs max. 5 Hz T a 8A/250V~ Hz VAC (0.24 ma/240 VAC) PHARAO 10 (AC) 4 relay (NO contact) VAC, +10%/-15%, 6 digital inputs max. 5 Hz T a 8/A250V~ 50-60Hz VAC (0.24 ma/240vac) PHARAO 11 (DC) 4 relays (NO contact) 24 V DC, +20%/-15% 6 analogue/digital eligible inputs max. 20Hz T a 8A/250 V~ 0-10 V DC or 24V DC, sink/source PHARAO 12 (DC) 4 transistor outputs 24 V DC, +20%/-15% 6 analogue eligible inputs max. 20 HZ T a 1A/24 DC 0-10 V DC order 24 V DC, sink/source PHARAO 20 (AC) 8 relays (NO Contact) VAD, +10%/-15% 12 digital inputs max. 5 Hz T a 8A/250V~ 50-60Hz 100V-240VAC (0.24mA/240VAC) PHARAO 21 (DC) 8 relays ( NO Contact) 24V DC, +20%/-15% 12 inputs : 4 digital inputs, max. 20 Hz T a 8A/250V~ 8 inputs alternatively analogue/digital, 0-10V DC or 24V DC, sink/source PHARAO 22 (DC) 8 transistor outputs 24V DC, +20%/-15% 12inputs : 4 digital inputs, max. 20 Hz T a 1A/24 DC 8 inputs alternatively analogue/digital, 0-10V DC or 24V DC, sink/source PHARAO-II 14 (AC) 6 relays (NO contact) VAC, + 10%/-15%, 8 digital inputs max. 20 Hz T a 8A/250V~ Hz PHARAO-II 15 (DC) 6 relays (NO contact) 24V DC, +20%/-15% 8 analogue/digital eligible inputs max. 20 Hz T a 8A/250V~ PHARAO-II 24 (AC) 4 relays a 8A/250V~ VAC, +10%/-15% 15 digital inputs max. 20 Hz T relays a 2A/250V~ 50-60Hz PHARAO-II 25 (DC) 4 relays a 8A/250V~ 24 V DC, +20%/-15% 15 inputs, 8 of them max. 20 Hz T relays a 2A/250V~ analogue/digital eligible inputs PHARAO-II VAC 4 digital inputs max. 20 Hz T Upgrade 4 ED (AC) 50-60Hz PHARAO-II 24V DC, +20%/-15% 4 digital inputs max. 5 Hz T Upgrade 4EDA(DC) PHARAO-II VAC 4 digital outputs 2x1 khz T Upgrade 4AR (AC) 50-60Hz Power unit 24VDC, 36W, 4 TE Luna 131 DDC combination sensor, temperature and brightness sensor for analogue inputs on PHARAO units, 0-10 VDC Pharao programing software, CD for windows 95/98/NT/2000/ME/XP, software for Pharao and Pharao-II generation Programming cable, PC/PHARAO PharaO-II GSM cable T T T T T Plug-in EEPROM, memory module T Plugs-in PHARAO-II EEPROM T Front panel installation kit T

16 Selection Table for Digital and Analog time switches Time Switch & Devices Program Contacts Contacts Minimum Nominal Power Distributor Wall Switch Flush Type distance trippable switching current at reserve panel mounting panel mounting < 3mm ( ) every.. time 250V~ approx. installation install DIGITAL 24h + 7 days Year Program 1s 1s 10A 10 years TR030 Top 1s 1s 16A 10 years TR 611 top 1s 1s 16A 10 years TR 611 top DCF 1s 1s 16A 8 years TR651 S 1min 1min 16A 3 years TR 608 top 1min 1min 16A 10 years TR 610 top 1min 1min 16A 10 years TR 635 top 1s 1s 16A 10 years TR 622 top 1s 1s 16A 8 years TR 652 S 1min 1min 16A 10 years TR 612 top 1min 1min 6A 10 years TR 636 top 1 min 1min 6A 10 years TR 685/2 top 1s 1s 10A 8 years TR 653 S 1s 1s 16A 1.5 years TR 641 S 1s 1s 16A 1.5 years TR 641 S DCF 1s 1s 16A 1.5 years TR 642 S 1s 1s 16A 1.5 years TR 642 S DCF 1s 1s 16A 1.5 years TR 644 S 1s 1s 16A 1.5 years TR 644 S DCF Program Contacts Contacts Minimum Nominal Power Distributor Wall Switch Type distance trippable switching current at reserve panel mounting panel < 3mm ( ) every.. time 250V~ approx. installation install 18.5 s 1.25 min 10 A TM 179 h 60 min 37.5 s 2 min 10 A TM 178 h 75 s 75 s 10 A TM 171 h 15 min 15 min 16 A 3 days SYN 160 a 15 min 15 min 16 A SUL 180 a 15 min 15 min 10 A SYN 169 s 15 min 15 min 10 A 3 days SUL 189 s 15 min 30 min 16 A SYN 168 h 24h 15 min 30 min 16 A 3 days SUL 188 h 30 min 30 min 16 A SYN 161 h 30 min 30 min 16 A 3 days SUL 181 h 5 min 20 min 6 A 150 h SUL 285/1 T 15 min 30 min 10 A SYN 168 g 15 min 30 min 10 A 3 days SUl 188 g 5 min 20 min 6 A 150h SUl 285/2 T 2 h 2 h 16 A 3 days MEM 190 a 1 h 3 h 16 A 3 days MEM 198 h 7 days 5/30 min 20 min/2h 10 A SYN 269 h 5/30 min 20 min/2h 10 A 3 days SUL 289 h 5 min 20 min 6 A 150h SUL 285 /1 TW 24h 5/30 min 20 min/2h 6 A SYN 269 g or 5/30 min 20 min/2h 6 A 3 days SUL 289 g 7 days 5/30 min 20 min/2h 6 A 150h SUL 285/2 TW adjustment 15 min 30 min 10 A 3 days SUL 189 hw 15 min 45 min 10 A SYN 168 hw 24h+2days 15 min 45 min 10 A 3 days SUL 188 hw same daily program on certain weekend especially suitable suitable to a limited extent ANALOG

DIN Rail Time & Twilight Switches

DIN Rail Time & Twilight Switches DIN Rail & Switches guard Limited, Victory Park, 00 Edgware Road, London NW ND. www.timeguard.com The New Generation of Analogue & Multi-Channel TR top Switches Section Overview Section Overview switches

More information

16-Channel Yearly Time Switch TR 648 S DCF

16-Channel Yearly Time Switch TR 648 S DCF 16-Channel Yearly Time Switch TR 648 S DCF Illustration 1 : TR 648 S DCF TR 648 S DCF EIB 648 9 201 DCF 77 Antenna 907 0 271 Obelisk 2.0 Programming set 907 0 305 Obelisk 2.1 Software 931 0 961 Page 1

More information

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC 2 2 309 429 01 TR TR 641 top2 641 0 100 TR 642 top2 642 0 100 TR 644 top2 644 0 100 TR 641 top2 RC 641 0 300 TR 642 top2 RC 642 0 300 TR 644 top2 RC 644 0 300 Installation and operating instructions Digital

More information

*Current connection required for smooth zerocrossing switch operation

*Current connection required for smooth zerocrossing switch operation 2 2 310 317 02 LUNA LUNA 109 109 0 100, 109 0 200 110 0 100, 110 0 200 GB Assembly and operating instructions Twilight Switch Test 2 2000 LUNA 109 I:2-35 II : 35-200 III : 200-1000 min max IV:1-5klx V:

More information

SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2

SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2 2 309 081 03 SELEKTA SELEKTA 170 top2 170 0 100 0,5mm - L N 230-240V~ Installation and Operating Manual Digital astronomic time switch MENU SELEKTA 170 top2 D F I E P NL PL 1 2 3 SELEKTA 170 top2 Correct

More information

Tempus Digital Digital Astro-Timer D GB CZ BZT28A71. Installation and Operating Manual BZT28A71

Tempus Digital Digital Astro-Timer D GB CZ BZT28A71. Installation and Operating Manual BZT28A71 2 8mm 310366 Tempus Digital Digital Astro-Timer BZT28A71 0,5mm - 2,5mm 2 0 6 12 18 24 L N 230-240V~ 50-60Hz R 10a -30T Installation and Operating Manual MENU OK BTZ28A71 D CZ PL HR 16(10)A 250V~ 1 2 3

More information

1. Contents Page. 2. Assembly, putting into operation, connection Control elements Display Factory setting Changing settings 6

1. Contents Page. 2. Assembly, putting into operation, connection Control elements Display Factory setting Changing settings 6 1. Contents 2 1. Contents Page 2. Assembly, putting into operation, connection 3 3. Control elements 4 4. Display 4 5. Factory setting 5 6. Changing settings 6 6.1 Time and day of the week 6 6.2 Calendar

More information

INSTAT 868 Radio Frequency Single-Room Controls

INSTAT 868 Radio Frequency Single-Room Controls INSTAT 868 Radio Frequency Single-Room Controls Easy to operate wireless application HEATING People Performance Products Climate Controls Europe An Invensys company Radio Frequency Controls Single-room

More information

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Radiocontrol F. Floor Heating Controller Radio control system for floor heating Radiocontrol F Floor Heating Controller Radio control system for floor heating IMI HEIMEIER / Floor Heating Control / Radiocontrol F Radiocontrol F The Radiocontrol F radio control system for controlling

More information

Proud Partners with MOBATime

Proud Partners with MOBATime Proud Partners with MOBATime Clock movement 192 /192 t for indoor and outdoor clocks up to Ø 80 cm. Radio controlled or synchronized by RS 232 / RS 422 or equipped with accurate quartz. Modular, state-of-the-art

More information

theben 4-/8-/12-Channel Switch Module Switch Actuator Modular with Basic Device RMG 4 - EIB and Additional Device RME 4 EIB

theben 4-/8-/12-Channel Switch Module Switch Actuator Modular with Basic Device RMG 4 - EIB and Additional Device RME 4 EIB 4-/8-/12-Channel Switch Module Switch Actuator Modular with Basic Device RMG 4 - EIB and Additional Device RME 4 EIB page 1 of 45 Table of Content... 1 1 Operational Characteristics... 2 2 Technische Daten...

More information

EIB/KNX Switch Actuators. User manual

EIB/KNX Switch Actuators. User manual EIB/KNX Switch Actuators User manual IT KNT 004 IT KNT 012 Tel.: +34943627988 E-mail: knx@dinuy.com Web: www.dinuy.com Contents 1. Introduction --------------------------------------------------------------------------------------------------------------

More information

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2 Digital time switch E N SHT-1 SHT-1/2 SHT-3 SHT-3/2 Content Symbol, Connection... 3 Warning... Characteristics... 5 Technical parameters... 6 Versions of time switches, Load... 7 Description... 8-9 Control...

More information

12 Series - Time switches 16 A. Features

12 Series - Time switches 16 A. Features 12 12 Series - Time switches 16 A Features Mechanical time switches - Daily time setting * - Weekly time setting ** Type 12.01-1 Pole 16 A CO (SPDT) 35.8 mm width Type 12.11-1 Pole 16 A NO (SPST-NO) 17.6

More information

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S.

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S. 310 415 TR 612 S Bedienungsanleitung (Seite 2 19) Operating Instructions (pag. 20 37) Mode d emploi (page 38 55) Bruksanvisning (S. 56 73) 2-Channel Time Switch EIB 8 GB 7 9 10 6 1 2 11 5 4 3 2 1 1 2 3

More information

Time switches 16 A NEON SЕRIES. Heating and cooling. Shop displays. Lighting for parks. Streetlights and car park lighting.

Time switches 16 A NEON SЕRIES. Heating and cooling. Shop displays. Lighting for parks. Streetlights and car park lighting. Heating and cooling NEON Shop displays Lighting for parks SЕRES Streetlights and car park lighting School bells FNDER reserves the right to alter characteristics at any time without notice. FNDER assumes

More information

Sauter Components

Sauter Components R 44.488/ QRK 0: Heating controller Used in conjunction with temperature detectors (Ni000) and appropriate control valves for heating and domestic-hot-water control (with various configurations), mainly

More information

Sentry Digital Timers

Sentry Digital Timers Sentry Digital Timers 0733s S4 Contents 1. Safety precautions 2. General rmation 3. DIN rail Installation 4. Display Layout. Programming 6. Technical Data 7. Guarantee 2 Safety precautions The connection

More information

Instruction manual. art Installation manual

Instruction manual. art Installation manual Instruction manual art. 01521 Installation manual Contents GENERAL FEATURES AND FUNCTIONALITY from page 4 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 6 COMMUNICATION OBJECTS GENERAL FEATURES AND

More information

OPERATING INSTRUCTIONS Digital weekly time switch

OPERATING INSTRUCTIONS Digital weekly time switch OPERATING INSTRUCTIONS Digital weekly time switch 1 Explanation of display and control buttons One-channel timer A B Two-channel timer 1.1 Control buttons i Set time and day of the week e Manual switching

More information

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature Temperature control: Feel good at any time of year Room thermostats Heating time switches Excellent products

More information

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Supercal 531 Multi function Integrator that lives up to Your highest expectations n Thermal Energy n Flow Metering n Supercal 531 Multi function Integrator that lives up to Your highest expectations Supercal 531 Multi functional integrator with unlimited options The Supercal 531 convinces

More information

Fixture Built-in Sensor Daylight Harvest Version

Fixture Built-in Sensor Daylight Harvest Version Fixture Built-in Sensor Daylight Harvest Version Model: HC419VRC /DH Infrared remote receiver Detection area Hold-time Daylight sensor Buzzer Sensor antenna Photocell Installation hole (4.2mm) 4.2 45 Stand-by

More information

Modular Devices - Indicators and Push Buttons

Modular Devices - Indicators and Push Buttons Modular Devices - Indicators and Push Buttons The new range of indicator lights and push buttons replaces and expands upon the whole SV range and is composed of the following three families Indicator Lights

More information

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators Thermostat P Thermostats Electronic room thermostat with clock for thermal actuators IMI HEIMEIER / Thermostats & Actuators / Thermostat P Thermostat P The Thermostat P room temperature controller is used

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

K-BUS Switch Actuator

K-BUS Switch Actuator K-BUS Switch Actuator User manual-ver. 2 KA/R0416.1 KA/R0816.1 KA/R1216.1 Contents Contents... 2 1. Introduction... 3 1.1 Product and function overview... 3 2. Technical Properties... 3 3. Commissioning...

More information

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification General The VT76x7 series is designed for single-stage and multi-stage control of heating/cooling equipment such as rooftop

More information

series dimmer actuators, DMG 2 S, Upgrade Module DME 2 S and Booster DMB 2

series dimmer actuators, DMG 2 S, Upgrade Module DME 2 S and Booster DMB 2 series dimmer actuators, DMG 2 S, Upgrade Module DME 2 S and Booster DMB 2 DMG 2 S 4910270 DME 2 S 4910271 DMB 2 4910272 Version: Jan-11 (Subject to change) Page 1 of 59 Contents 1 FUNCTIONAL CHARACTERISTICS...

More information

Remote Radio Control. WAVE Push button radio control systems

Remote Radio Control. WAVE Push button radio control systems Remote Radio Control WAVE Push button radio control systems Application Radio Remote Controls have become a key element within a wide range of modern working environments where safety, productivity and

More information

PRODUCT LEAFLET AUGIER-BOX. Remote Monitoring Unit for Street Lighting /07/2011

PRODUCT LEAFLET AUGIER-BOX. Remote Monitoring Unit for Street Lighting /07/2011 PRODUCT LEAFLET AUGIER-BOX Remote Monitoring Unit for Street Lighting 1 60 11432-04/07/2011 Put a TECHNICIAN in each street lighting cabinet, and control them 24H per day! The Augier-Box Programmable Logic

More information

Mechanical daily time switch. 35 mm rail (EN 60715) mount

Mechanical daily time switch. 35 mm rail (EN 60715) mount SERES SERES Mechanical time switches - Daily time setting* - Weekly time setting**.01.11.31 Type.01 --Daily --1 CO 16 A --35.8 mm wide --35 mm rail mount Type.11 --Daily --1 O 16 A --17.5 mm wide --35

More information

Contents. Time switches. Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8

Contents. Time switches. Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8 Contents Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8 Practical advice 15 A few principles 15 Programming examples 16 Updated: 27/8/03 1 Presentation For all sectors

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

EasyclickPro. Wireless Control Systems Making light work

EasyclickPro. Wireless Control Systems Making light work EasyclickPro Wireless Control Systems Making light work EasyclickPro EasyclickPro RF system The new Easyclick generation Honeywell Easyclick wireless and battery-less solutions for lighting, shutter and

More information

Modular Devices and Enclosures

Modular Devices and Enclosures Modular Devices and Enclosures Features Modular contactors for control of motor, heating and lighting applications Digital and Analogue Time Switches for remote command and control of circuits Selectable

More information

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

C4000. inline control. Photometric Converter.  Real-time photometric converter. Factory zero for scattered light sensors C4000 Photometric Converter inline control Real-time photometric converter Factory zero for scattered light sensors Simultaneous operation of up to four inline sensors Process control functions via Remote

More information

This data sheet is only valid in association with the IL SYS INST UM E user manual.

This data sheet is only valid in association with the IL SYS INST UM E user manual. Inline counter terminal, version for extreme conditions, 1 counter input, 1 control input, 1 output, 24 V DC, 500 ma Data sheet 106148_en_03 PHOENIX CONTACT 2015-11-04 1 Description The terminal is designed

More information

Connecting Mains Electrical Power

Connecting Mains Electrical Power Tide Level Monitoring Instrumentation The following documentation details the electrical installation for the tide level monitoring instrumentation and also a summary of the logger configurations required

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

Protection relays and transformers

Protection relays and transformers NEW ZEALAND WWW.LPINZ.CO.NZ Unit 6/22 Moselle Ave, Henderson, Auckland, New Zealand PO Box 21-872, Henderson, Auckland, New Zealand Phone:+64 9 833 5749 Email:info@LPINZ.co.nz Web: www.lpinz.co.nz Protection

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules SESOTEC MB Sensor Modules 110042808 SESOTEC MB HF1 COM1 110051733 SESOTEC MB HF1 DAI 110059684 SESOTEC MB HF2 COM1 Function description With the new HF sensor modules, you,

More information

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB

Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG DME DMB Series Dimmer Actuator DMG 2, Upgrade Module DME 2 and Booster DMB 2 DMG 2 490 0 220 DME 2 490 0 221 DMB 2 490 0 222 Date: Aug-07 (subject to alterations) Page 1 of 36 Contents 1 FUNCTIONAL CHARACTERISTICS...

More information

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd Digital 7-Day Programmable Timer 4TCD1 Schneider Electric (Australia) Pty Ltd Contact us: clipsal.com/feedback National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56 Installation Instructions

More information

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm. Series Digital LCD Timer DIN W48 H48mm Features Power supply : 4-4VAC 5/6Hz, 4-4VDC universal Easy to switch Up/Down mode programmable output modes and timing ranges () Selectable function by front digital

More information

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF 310 785 01 TR 611 top TERMINA 1-channel 7 day timer According to version Preprogrammed with the current time and summer/ winter norm time Safety Information The connection and installation of electrical

More information

Relais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE

Relais und Automatisierungssysteme JUST IN TIME. with the. New Generation NGG. from Schleicher NGG CATALOGUE JUST IN TIME with the New Generation NGG from Schleicher NGG CATALOGUE General information on the New Generation NGG Quality control 2 Norms, regulations, approvals 2 Housing system, conductor sizes 3

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

ISOMETER IRDH575. Approvals

ISOMETER IRDH575. Approvals Insulation monitoring device for unearthed AC, DC and AC/DC systems (IT systems) with control and display function for EDS insulation fault location systems IRDH575_D00089_02_D_XXEN/09.2018 Insulation

More information

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal.

The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal. , GH Q631 0026 R0111 SK 0097 B97 The universal input/output device is a DIN rail mounted device. It is connected to the EIB via a bus connecting terminal. The device has 32 freely programmable inputs/outputs,

More information

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2 KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2 4940212 4940217 2018-10-17 Contents 1 Function description 3 2 Operation 4 3 Technical data 5 4 The FIX2 RM 8 H application programme

More information

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip

More information

Wireless Control Systems

Wireless Control Systems Wireless Control Systems Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Receivers Accessories Programming Switching & Dimmer Functions

More information

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

Original operating instructions Fail-safe inductive sensor GG507S / / 2013 Original operating instructions Fail-safe inductive sensor GG507S 80005283 / 00 05 / 2013 Contents 1 Preliminary note...3 1.1 Explanation of symbols...3 2 Safety instructions...4 2.1 Safety-related requirements

More information

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL CS-200 Operation and Service Manual Page 2 Manufactured by: LINCAST INTERNATIONAL PTY. LTD. 2/3 Sir Laurence Drive

More information

MT372 Three-phase electronic meter with built-in modem or RS485 communication interface

MT372 Three-phase electronic meter with built-in modem or RS485 communication interface Energy Measurement and Management MT372 Three-phase electronic meter with built-in modem or RS485 communication interface Technical Description Version 1, 09.06. 2005 Content: MT372 Three-phase electronic

More information

SONOMETER TM 1100 Ultrasonic compact energy meter

SONOMETER TM 1100 Ultrasonic compact energy meter Data sheet SONOMETER TM 1100 Ultrasonic compact energy meter Description/Application MID examination certificate no. : DE-10-MI004-PTB003 The SONOMETER 1100 is an ultrasonic static compact energy meter

More information

Radio-control universal dimmer (built-in type) Installation Instructions

Radio-control universal dimmer (built-in type) Installation Instructions 2-Channel Time Switch Order no.: 1073 00 1 Programming / checking mode 2 Button for setting current time 3 Button for setting day of the week 4 Days of the week (1 = Mon, 2 = Tues, 7 = Sun) 5 Cursor t

More information

Switching and control professionals electronic switching relays, control relays and coupling relays

Switching and control professionals electronic switching relays, control relays and coupling relays 12 Switching and control professionals electronic switching relays, control relays and coupling relays 12 Electronic switching relays, control relays and coupling relays Selection table switching relays,

More information

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver Page 1/13 JUMO Wtrans E01 Measuring probe for humidity, temperature, and CO 2 with wireless data transmission Humidity from 0 to 100 % RH (incl. -40 to +80 C) or CO 2 from 0 to 2000/5000/10000 ppm or Temperature

More information

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Solid-state Timer CSM DS_E_

More information

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001

Time Switch, 2-channel, MDRC SW/S 2.5, GH Q R0001 , GH Q605 0062 R0001 The 2-fold week time switch is a DIN rail mounted device with a width of two modules for insertion in the distribution board. It is connected to the EIB via a bus connecting terminal.

More information

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W

1. Function. Universal dimming actuator REG-K/2x230/ 300 W. Universal dimming actuator REG-K/230/ 500 W. Universal dimming actuator REG-K/230/ 1000 W L L N N on error RUN 1 2 3 4 KNX EIB 1 1 1 1 Chapter 9: Dimming actuators/control units Chapter 9:Dimming actuators/control unitsart. no.6493xxas of 10/079.2Universal dimming actuators Universal dimming

More information

KNX manual 1-channel flush-mounted switch actuator SU 1

KNX manual 1-channel flush-mounted switch actuator SU 1 KNX manual 1-channel flush-mounted switch actuator SU 1 4942520 2018-10-04 Contents 1 Function description 3 2 Operation 4 3 Technical data 5 4 The SU 1 application programme 7 4.1 Selection in the product

More information

Rotational speed controller

Rotational speed controller Model number Features Rotational speed monitoring up to khz pre-select value with relay output and LED indicator Multi-range power pack -, -, -wire and NAMUR sensors as well as rotary encoder connectable

More information

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features Product Guide EBDHS-MB-AT-DD RF ceiling PIR presence detector DALI / DSI dimming Overview The EBDHS-MB-AT-DD is a passive infrared (PIR) motion sensor combined with two output channels capable of controlling

More information

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry

SERVICE-MANUAL ROOM TEMPERATURE CONTROLLER NEA 230V / 24V. Construction Automotive Industry ROOM TEMPERATURE CONTROLLER NEA 230V / 24V Construction Automotive Industry ROOM TEMPERATURE CONTROLLER NEA 230V / 24V TABLE OF CONTENTS 1....... Information and safety guidelines......................................................

More information

Intelligent Compact Controller

Intelligent Compact Controller TCY-T0121 Intelligent Compact Controller Features Temperature control for 2-pipe, 4-pipe HVAC systems. Temperature range from 40 to 140 C. 1 independent PI and On/Off control loop to control temperature.

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories DZD 92 L Multi-Function - Multi-domain time relay Mono voltage 8 Functions Setting range 0.05 s to 100 h subdivided into 7 time domains 1 immediate-action and 1 time contact or 2 time contacts (adjustable)

More information

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics Dewpoint-guided Power Controller for Glass and Handrail Heaters Front view Characteristics Dew point-guided power controller for cost-optimized operation of glass and handrail heaters Digital display of

More information

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM

Rev ABB i-bus KNX 6151/11 U-500. Power and productivity for a better world TM 1 73-1-7831 Rev. 01 3.2012 6151/11 U-500 Power and productivity for a better world TM Page: 1 of 31 Switching actuator 1gang with binary Inputs, FM Actuator Article-no.: 6151/11 U-500 ETS search path:

More information

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting Data Sheet 10/86-2.36-EN All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting Compact robust power relay Type RH(M) 1003: 3 changeover contacts Type RH(M) 1004: 4

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LH24A-00 Communicative linear actuator adjusting dampers and slide valves in technical building installations Air damper size up to approx. m² Actuating force 50 N Nominal voltage AC/DC

More information

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003 MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003 INSTRUCTIONS MANUAL Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com General Description Indoor universal mechanism box mounted KNX motion

More information

RF ceiling microwave presence detector DALI / DSI

RF ceiling microwave presence detector DALI / DSI MWS3A-AT-DD Product Guide RF ceiling microwave presence detector DALI / DSI Overview The MWS3A-AT-DD is a passive microwave motion sensor combined with two output channels capable of controlling incandescent,

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Radio controllers. Innovation combined with skill and tradition. Intelligent solutions. for all living spaces. Radio-controlled regulation

Radio controllers. Innovation combined with skill and tradition. Intelligent solutions. for all living spaces. Radio-controlled regulation Radio controllers Radio-controlled regulation The radio-controlled temperature regulation of domestic heating systems is ideally suited for both new build and renovation projects. It also offers increased

More information

PHOENIX CONTACT - 03/2007

PHOENIX CONTACT - 03/2007 Inline Function Terminal for Pulse Width Modulation and Frequency Modulation N AUTOMATIONWORX Data Sheet 6920_en_01 1 Description PHOENIX CONTACT - 03/2007 $ ' ) The terminal is designed for use within

More information

Radio controlled home automation

Radio controlled home automation Radio controlled home automation for retro-fit and new projects Hager quicklink is a home automation system accessible to all installers. It's an easy to use radio operation, offering control of applications

More information

REMOTE SENSOR SERIES. Description

REMOTE SENSOR SERIES. Description REMOTE SENSOR SERIES Telco s remote sensor series can always be depended on to do the job. Although simple in design and modest in size, nothing performs more reliably in hostile environments and challenging

More information

DDC control of package units, heat pumps, unit ventilators, and other terminal unit applications

DDC control of package units, heat pumps, unit ventilators, and other terminal unit applications Infinity TCX 867 Terminal Control Unit F E A T U R E S The Infinity TCX 867 programmable controller is a compact terminal control unit that provides lowcost DDC control of package units, heat pumps, unit

More information

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26 309 484 01 RAMSES 784 HF Set 1 784 9 407 784 9 417 Bedienungsanleitung Uhrenthermostat 1 Operating Instructions Clockthermostat 14 Mode d emploi Thermostat à horloge 26 Gebruiksaanwijzing Klokthermostaat

More information

Original operating instructions Fail-safe inductive sensor GM504S / / 2010

Original operating instructions Fail-safe inductive sensor GM504S / / 2010 Original operating instructions Fail-safe inductive sensor GM504S 704070 / 01 06 / 2010 Contents 1 Preliminary note 3 1.1 Explanation of symbols 3 2 Safety instructions 4 2.1 Safety-related requirements

More information

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features Product Guide EBDHS-AT-DD RF ceiling PIR presence detector DALI / DSI dimming Overview The EBDHS-AT-DD is a passive infrared (PIR) motion sensor combined with two output channels capable of controlling

More information

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease Fluke 1740 Series Three-Phase Power Quality Loggers Memobox Technical Data Assess power quality and conduct long-term studies with ease Compact and rugged, the Fluke 1740 Series three-phase power quality

More information

Data Acquisition Modules/ Distributed IO Modules

Data Acquisition Modules/ Distributed IO Modules User Manual Data Acquisition Modules/ Distributed IO Modules Future Design Controls, Inc. 7524 West 98 th Place / P.O. Box 1196 Bridgeview, IL 60455 888.751.5444 - Office: 888.307.8014 - Fax 866.342.5332

More information

Silent Gliss. Control Systems

Silent Gliss. Control Systems Control Systems Application Chart Motor Control System Infrared Remote Control d Transmitter Wall Transmitter Radio Receiver / Control Unit DC System 2160 9946, 9948 9068, 9944, 9945 2195 9005, 9006 9946,

More information

Introduction DIN rail mounted electricity meters

Introduction DIN rail mounted electricity meters Introduction DIN rail mounted electricity meters Modular DIN Rail Products offer a wide range of functions to be integrated in electrical installations with significant benefits for the user. DIN rail

More information

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow Sense Command Control Third Eye Energy Saving Sensors Save Energy Today for a Better Tomorrow Save Energy Today for a Better Tomorrow Motion Sensor History The first motion detector burglar alarm was invented

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers

More information

AT-SL-ADR & AT-SL-ADR/SA

AT-SL-ADR & AT-SL-ADR/SA AT-SL-ADR & AT-SL-ADR/SA RF 1-10V + relay controller Product Guide Overview The AT-SL-ADR and AT-SL-ADR/SA are wireless controllers with two output channels capable of controlling incandescent, fluorescent

More information

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Modular versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Smart "Compact" range with display CD12 Smart Part number 88974043 "Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting Type Input

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Automation and control equipment

Automation and control equipment Automation and control equipment D. Latching relays - Latching relays auxiliaries D. Relays - Interface relays D.5 Contactors and override contactors D.6 Electromechanical time switches D.8 Analogue time

More information

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton Edition 10/2016 HMI Components 41 Series Characteristics The rectangular design of the Series 41 (18 x 24 mm) makes it especially suited: Raised design PCB (with adaptor) Functions The Series 41 incorporates

More information

Control solutions Biofloor

Control solutions Biofloor MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital

More information

CAMTO. Arc detecting relay. system. January Revised August D D1200

CAMTO. Arc detecting relay. system. January Revised August D D1200 NEW ARC DETECTING SYSTEM FROM Based on our experience with arc protection since 1962, has developed a new. The units are built into boxes that all fit on a 35 mm DIN-rail. All front plates are dimensioned

More information

Computer-14d - xx - 144a

Computer-14d - xx - 144a POWER FACTOR REGULATOR Computer-14d - xx - 144a INSTRUCTION MANUAL ( M 981 602 / 98B ) (c) CIRCUTOR S.A. -------- POWER FACTOR REGULATOR COMPUTER- 14d --------- Page 2 1.- POWER FACTOR REGULATORS COMPUTER-14d-144a

More information