1 RAMSES 784 HF Set Bedienungsanleitung Uhrenthermostat 1 Operating Instructions Clockthermostat 14 Mode d emploi Thermostat à horloge 26 Gebruiksaanwijzing Klokthermostaat 38 Istruzioni d uso Cronotermostato 50

2 Designated Use The RAMSES 784 HF thermostat and receiver REC MHz (single channel) are suitable for wireless room temperature regulation. The RAMSES 784 HF timer thermostat radio-controls receivers REC 1 by time and room temperature. It may only be used in dry, domestic environments. The receiver is to be installed near to an electrical appliance with a maximum current draw of 6 A, e.g. mechanical mixer valve. The appliance is switched on and off independent of the radio-transmitted room thermostat control signal. Safety Instructions WARNING Danger of death through electric shock or fire! Installation should only be carried out by professional electrician! Information Battery/battery change Set/correct actual time Summer/winter time adjustment Set temperature Manual switching Program heating time (day program) Switch over day/ week program Program heating time (week program) Safety instructions Installation Connection Matching to the heating Adjusting operating point Technical data 14

3 RAMSES 784 HF RAMSES 784 HF Day/week program switchable with tappets 2 Manual switching and display normal r or energy saving operation m (night) 3 LED displays heating operation / LED flashing, battery change necessary 4 Electronic feedback for adjustment to your heating 5 Ventilation apertures in the plinth 6 Setting normal temperature r (day) 7 Program selection switch (normal operation in position AUTO n or continuously normal r or energy saving operation m protection operation + 6 C f 8 Temperature compensation for adjustment to the location conditions 9 Setting the set-back temperature m (energy saving program) 10 Battery compartment 11 Seal for product security 15

4 Mounting and Electrical Connection 11 5 OK -> Do not mount the device on an even conductive base. 1. Lower the front cover. 2. With a screwdriver turn the seal 11 to position. 3. Lift the grey plinth from the control section. 4.Fix the plinth to the wall approx. 1.5 m above the floor, if possible on an internal wall, against which air can circulate without hindrance. 5. Fit the clock thermostat to the plinth. 6. Turn the seal 11 into position with a screwdriver. -> Keep the ventilation apertures 5 in the plinth free, no paint, wallpaper or other such material. 16

5 The clock thermostat is battery powered. Depending on switching frequency, you must change the batteries after approx. 12 months. First time of operation: 1. Note the polarity of the batteries. 2. Place the batteries in the battery compartment. Battery change necessary: LED 3 flashes Action: Change the old batteries within 3 weeks. If action not taken: Changing batteries: Recommendation: The LED is illuminated after this for a few days continuously. Afterwards the clock stops, the heating switches on continuously, but is not controlled. 1. Take out the used batteries. 2. Dispose of the batteries in an environmentally friendly way. 3. Use only new similar type alkaline cells LR6. 4. Note the polarity and fit the batteries. Check the batteries from time to time. Leaking batteries damage your product. REC 1 The device is designed for installation on DIN top hat rails (in accordance with EN 60715) or for wall installation with wall installation set A B C D Override switching C1 ON/OFF Status display channel C1 Level display for reception quality Antenna connection 17

6 REC 1 Connection is made at terminals 1, 2, 3. * * Circulating pump, actuator for radiators etc. -> For the connection of a boiler (gas/oil) use the connecting terminals 1-2 (in accordance with manufacturer data). Installation and Operation For operation of RAMSES 784 HF follow the sections: REC 1 1. Alignment of the antenna Assumption: The product REC 1 is connected to mains voltage. For optimum reception, the antenna must be in a vertical position. In a few exceptional cases, interference signals can be received from the surrounding area. Depending on the strength of the interference several LEDS may be illuminated. -> Align the antenna in such a way that as few LED s as possible are illuminated. -> Do not install the antenna near water or electrical circuits! 2. Optimising the reception quality The channel C1 at the receiver must be OFF, i.e. the corresponding status display(s) (LED) must be OFF. To connect RAMSES 784 HF to the power supply and set time etc., follow the instructions: -> Set rotary switch on the back (printed circuit) of RAMSES 784 HF to position 10 HF-Test. 18

7 The room thermostat now transmits for 15 mins. at regular 3 second intervals. The control display on the receiver and the channel status display light up during this cycle. During the test phase, the location of the regulator and therefore the reception quality can be optimised. The relays are not switched. -> Place the controller in the desired living area. Optimal Reception: When all LEDs are lit during transmission. However, at least one green LED must be lit. Premature cancellation: -> Set rotary switch to position 1 Automatic. Reception quality can, if necessary, be improved by the rod antenna available as accessory equipment. 3. Override Switching REC 1 Switch channel C1 ON/OFF: -> Briefly (approx. 1 sec) press button C1. Channel ON The LED on C1 lights up. Channel OFF: The LED on C1 goes off. 4. Verifying codes/codierung Transmitting and receiving products are already tuned and coded to one another in the factory. First test of channel C1 (e.g. Room 1) When control unit REC 1 is in view: -> Set rotary switch on back (on printed circuit board) of RAMSES 784 HF to position 10 Test-HF. The LED on channel 1 and the level indicator light up briefly. 5. Clearing codes Attention: Please cancel the previous code before fixing/coding the new one. -> Press the C1 button on REC 1 for approximately 10 secs. The LED of C1 is illuminated and goes off again after 3 secs. The coding is cancelled. Test: -> Run the Test-HF function on room thermostat. The level indicator illuminates. The LED on C1 (C2) should not be lit. Repeat the procedure if necessary. 19

8 6. Re-coding Several products can be used in a residential unit without them having a negative effect on one another. Coding of Channel C1 (eg. Room 1) -> Press the button C1 of REC 1 approx. 5 secs. The LED on C1 flashes for approx. 10 secs., during which the Coding function on the room thermostat must be run. -> Set rotary switch on the back (printed circuit) of RAMSES 784 HF to position 9 Coding. The level display on the receiver lights up briefly. Test: If you run the Coding function again, the channel status display lights up as well as the level display. 7. Response to a fault Transient malfunction: The relay's switching status is not affected because the switching commands are transmitted several times. Transmission failure: The receiver switches to emergency mode after two hours, relay switches in cycles, 2 mins. on, 8 mins. off. Power failure: Relays fall idle. The previous switching status is saved and resumed when the power is returned. The relays resume their correct switching status after a maximum of 30 mins. 20

9 14 2 e.g Setting Actual Time or Adjusting Summer/Winter Time Note: -> Turn the big hand in a clock-wise or anti clock-wise direction until the actual time is displayed. e.g hours, not 2.00 hours! C 2 Normal program 9 16 C Set back temperatur Manual switching/override switching in place 2 in pos. r, the setting on rotary switch r (6) determines the temperature 2 in pos. m, the setting on rotary switch m (9) determines the temperature Note: The temperature reduction by 1 C means approx. 6 % energy saving. 21

10 20 min. 5 min. Example: daily from 6.00 to hours normal program r -> Push the red tappet onto 6 hours. -> Push the blue tappet onto 8 hours. Dayprogram Product type RAMSES 784 HF can be switched from day to week program or vice versa. -> Take off the graduated ring. -> Turn the big hand until the groove in the blue and the groove in the green ring cover each other. -> Slide the drive pin into pos. 7d. 22

11 Weekprogram -> Turn the graduated ring over and -> set up again. 16 C 20 C theben Nr theben Nr p. ex. V = fr Example for weekprogram: mo - fr: 4 AM - 8 AM + 4 PM - 8PM/ sa: 8 AM - mid-night / su: 8 AM - 20 PM finish energiesafeingprogram r start comfortprogram m finish comfortprogram m start energiesafeingprogram r Insert alternate mo (I) to fr (V): sa (VI): su (VII): Note: a red tappet at 4 AM and a blue tappet at 8 AM a red tappet at 4 PM and a blue tappet at 20 PM a red tappet at 8 AM and a blue tappet at mid-night a red tappet at 8 AM and a blue tappet at 8 PM The tappets must be pressed down until the boss engages. 23

12 Only for Qualified Electrician Electronic feed-back The clock thermostat is set in the factory to usual heating systems in practical operation. If, as a consequence of the heating system, an adjustment is necessary, select the recommended setting on the potentiometer (rotary knob) 4. Pos 1: 4 Pos 2: for floor heating/ bi-metal mixer/ oil furnance for slow mixing valve Pos 3: for circulation pump/ rapid mixing valve Pos 4: for gasheating/storage heating/magnetic valve Adjustment of the operating point 8 The clock thermostat is adjusted in the factory. If re-setting is necessary due to the place of installation e.g. a cold cement wall, the measured temperature deviation can be corrected with the pentiometer 8. Example: Controlled temperature too high -> Turn the potentiometer (rotary switch) in anti-clockwise direction, see illustration. 24 After the roomtemperature is stabilized, repeat if necessary.

13 Technical Data RAMSES 784 HF Batteries: 2 x 1,5 V (Alcaline LR6) Hysteresis: approx. 0,4 1,2 K Battery life: approx. 1 year Protection rating: IP 20 in accordance with EN Protection class: III in accordance with EN Ambient temperature: 0 C 40 C RS type 1 in accordance with EN / EN Pollution degree: 2 REC 1 (868 MHZ) Operating voltage: 230 V / 50 Hz Contact: gap <3 mm (μ) Power consumption: <2,5 W Protection rating: IP 20 in accordance with EN Protection class: II in accordance with EN for designated installation Ambient temperature: 0 C 55 C RS Typ 1B in accordance with EN / EN Pollution degree: 2 Rated impulse withstand voltage: 4 kv The product complies with the essential requirements and other relevant regulations of the RTTE Directive 1999/5/EEC. C EU CH Environmental information The equipment that you bought has required the extraction and use of natural resources for its production. It may content hazardous substances for the health and the environment. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems. Those systems will reuse or recycle most of the materials of your end life equipment in a sound way. The crossed-bin symbol invites you to use those systems. If you need more information on the collection, reuse and recycling systems, please contact your local or regional waste administration. You can also contact us for more information on the environmental performances of our products. 25

14 Theben AG Hohenbergstr Haigerloch DEUTSCHLAND Fon +49 (0) 74 74/ Fax +49 (0) 74 74/ Service Fon +49 (0) 74 74/ Fax +49 (0) 74 74/ Addresses, telephone numbers etc. at

SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2

SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2 2 309 081 03 SELEKTA SELEKTA 170 top2 170 0 100 0,5mm - L N 230-240V~ Installation and Operating Manual Digital astronomic time switch MENU SELEKTA 170 top2 D F I E P NL PL 1 2 3 SELEKTA 170 top2 Correct

More information

Wireless Room Thermostat Installation and Operation Y6630D1007

Wireless Room Thermostat Installation and Operation Y6630D1007 Wireless Room Thermostat Installation and Operation Y6630D1007 General safety instructions Contents 1. General safety instructions... 3 1.1. Commissioning the relay module HC60NG... 3 2. Overview... 4

More information

*Current connection required for smooth zerocrossing switch operation

*Current connection required for smooth zerocrossing switch operation 2 2 310 317 02 LUNA LUNA 109 109 0 100, 109 0 200 110 0 100, 110 0 200 GB Assembly and operating instructions Twilight Switch Test 2 2000 LUNA 109 I:2-35 II : 35-200 III : 200-1000 min max IV:1-5klx V:

More information

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S.

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S. 310 415 TR 612 S Bedienungsanleitung (Seite 2 19) Operating Instructions (pag. 20 37) Mode d emploi (page 38 55) Bruksanvisning (S. 56 73) 2-Channel Time Switch EIB 8 GB 7 9 10 6 1 2 11 5 4 3 2 1 1 2 3

More information

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators Thermostat P Thermostats Electronic room thermostat with clock for thermal actuators IMI HEIMEIER / Thermostats & Actuators / Thermostat P Thermostat P The Thermostat P room temperature controller is used

More information

LK Wireless Room Control Cq

LK Wireless Room Control Cq LK Wireless Room Control Cq Description LK Wireless Room Control Cq consists of a LK Room Thermostat Cq-n (transmitter) and a LK Receiver Unit Cq 8 (8 channel receiver unit). The range also includes a

More information

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC 2 2 309 429 01 TR TR 641 top2 641 0 100 TR 642 top2 642 0 100 TR 644 top2 644 0 100 TR 641 top2 RC 641 0 300 TR 642 top2 RC 642 0 300 TR 644 top2 RC 644 0 300 Installation and operating instructions Digital

More information

TWS 16 PT UHF wireless system. user manual

TWS 16 PT UHF wireless system. user manual TWS 16 PT UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 17.11.2015,

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

TWS 16 HT UHF wireless system. user manual

TWS 16 HT UHF wireless system. user manual TWS 16 HT UHF wireless system user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-66 E-mail: info@thomann.de Internet: www.thomann.de 30.04.2012 Table

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

TWS 16 BT UHF wireless system. user manual

TWS 16 BT UHF wireless system. user manual TWS 16 BT UHF wireless system user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 email: info@thomann.de Internet: www.thomann.de 09.03.2012 Table

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature Temperature control: Feel good at any time of year Room thermostats Heating time switches Excellent products

More information

Mx-D15 Intelligent Valve Actuator

Mx-D15 Intelligent Valve Actuator Application Small radio controlled, battery-powered actuator for room temperature control. For thermostat valve bodies for direct mounting on commercially available radiator valves for room-specific temperature

More information

Wireless valve actuator for bidirectional EnOcean communication. The SAB05 combines with message server and enocean transmitter.

Wireless valve actuator for bidirectional EnOcean communication. The SAB05 combines with message server and enocean transmitter. SAB05 EasySens wireless radiator valve actuator for room temperature control Data Sheet Subject to technical alteration Issue date: 26.11.2015 Application Wireless valve actuator for bidirectional EnOcean

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

Seite 2 Standard-Empfänger. EN Operation Instructions

Seite 2 Standard-Empfänger. EN Operation Instructions sign lux DE Bedienungsanleitung Seite 2 Standard-Empfänger EN Operation Instructions Page 10 Standard receiver FR Mode d emploi Page 18 Récepteur standard NL Gebruiksaanwijzing Pagina 26 Standaard ontvanger

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

R PROFLAME Instruction Book Collection

R PROFLAME Instruction Book Collection 9.956.028 R00 584 PROFLAME Instruction Book Collection 4-17 18-29 584 PROFLAME System 30-39 Appendix: DIP SWITCH NUMBER (0=ON 1=OFF) 40-41 4-17 Fig. 1 The SIT is a device that allows, in conjunction with

More information

Control solutions Biofloor

Control solutions Biofloor MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this compact 868MHz Temperature Station which displays radio controlled time, date, indoor and outdoor

More information

Wireless multizone receiver RDE-MZ6

Wireless multizone receiver RDE-MZ6 s 1 428 Wireless multizone receiver RDE-MZ6 for floor heating / zone heating systems Mains-powered RDE-MZ6 multizone wireless receiver (AC 230 V) DIN rail mounting 2-position control with On/Off output

More information

Self-learning Room Temperature Controller Receiver

Self-learning Room Temperature Controller Receiver 2 265 REV23RF REV-R.02/1 REV23RF/SE Self-learning Room emperature Controller Receiver Consisting of controller (with integrated radio transmitter) and receiver (switching unit with relay outputs) REV23RF

More information

Tube Facing Tool.

Tube Facing Tool. www.swagelok.com Tube Facing Tool This manual contains important information for the safe and effective operation of the Swagelok TF72 series tube facing tool. Users should read and understand its contents

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this temperature station with wireless 868MHz transmission. It not only displays the indoor temperature

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 OPERATING INSTRUCTIONS ARE ON PAGE 5 RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 This Programmable Ravenheat R/F controlled room Thermostat RVHT 2, consists of 2 items: a Mobile Transmitter

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this temperature station with wireless 868 MHz transmission of outdoor temperature and display of indoor

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

Bedienungsanleitung Handsender HSP 4 BiSecur

Bedienungsanleitung Handsender HSP 4 BiSecur www.samsondoors.co.uk 0800 328 6250 DE EN FR NL IT ES PT Bedienungsanleitung Handsender HSP 4 BiSecur Operating instructions Hand transmitter HSP 4 BiSecur Instructions d utilisation Emetteur HSP 4 BiSecur

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx KNX radio wall-transmitter 1gang/2gang flat quicklink KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx KNX radio wall-transmitter 1gang/2gang flat solar quicklink Order no.:

More information

User Instructions For TopTronic RS-10

User Instructions For TopTronic RS-10 User Instructions For TopTronic RS-0 409ENG-Dec0 Hoval Ltd Northgate Newark Nottinghamshire NG4 JN Phone 066 677 Fax 066 675 Index 409ENG-Dec0 Introduction Introduction... Controls... Display... User instructions

More information

Bedienungsanleitung Handsender HS 5 BiSecur

Bedienungsanleitung Handsender HS 5 BiSecur DE EN FR NL IT ES PT Bedienungsanleitung Handsender HS 5 BiSecur Operating instructions Hand transmitter HS 5 BiSecur Instructions d utilisation Emetteur HS 5 BiSecur Bedieningshandleiding Handzender HS

More information

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM) PH-BSP WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM) Wireless control unit Two-way radio communication on 433.92 MHz Comfortable solution of room heating Predictive system

More information

free solo PT UHF wireless system user manual

free solo PT UHF wireless system user manual free solo PT UHF wireless system user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 22.01.2013 Table

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No ALTHC015 RT300RF Manual Altech 005_89 06/05/2014 08:56 Page 2 2 ALTHC015 INSTRUCTION

More information

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2 Digital time switch E N SHT-1 SHT-1/2 SHT-3 SHT-3/2 Content Symbol, Connection... 3 Warning... Characteristics... 5 Technical parameters... 6 Versions of time switches, Load... 7 Description... 8-9 Control...

More information

LP20RF & DIGISTAT+RF. Installation & User Guide PRINT. Radio frequency controlled room thermostat with dual channel programmer. Part number RF562DR

LP20RF & DIGISTAT+RF. Installation & User Guide PRINT. Radio frequency controlled room thermostat with dual channel programmer. Part number RF562DR Radio frequency controlled room thermostat with dual channel programmer Part number RF562DR Spares Part number 31003 Spares Part number 22590DR! For GREENSTAR CDi, GREENSTAR i JUNIOR and GREENSTAR Si MODELS

More information

Communicative heating controller

Communicative heating controller UC100 Communicative heating controller Summary UC100 is a communicative room heating controller with one PWM output for control of a radiator or electrical heater. It can work autonomously, or in connection

More information

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Radiocontrol F. Floor Heating Controller Radio control system for floor heating Radiocontrol F Floor Heating Controller Radio control system for floor heating IMI HEIMEIER / Floor Heating Control / Radiocontrol F Radiocontrol F The Radiocontrol F radio control system for controlling

More information

INSTAT 868 Radio Frequency Single-Room Controls

INSTAT 868 Radio Frequency Single-Room Controls INSTAT 868 Radio Frequency Single-Room Controls Easy to operate wireless application HEATING People Performance Products Climate Controls Europe An Invensys company Radio Frequency Controls Single-room

More information

THANK YOU! Crush Micro PiX. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

THANK YOU! Crush Micro PiX. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club! THANK YOU! Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club! Since 1968 when the company was founded, Orange has been a pioneering force in the

More information

Radio System Strobe Wizard Plus Freemask

Radio System Strobe Wizard Plus Freemask Radio System Strobe Wizard Plus Freemask User manual Translation of the original German user manual Doc. No.: 900.0509.00 Version: 09/2017 Contents Information about this manual and about the manufacturer...

More information

WIRELESS 868 MHz WEATHER STATION

WIRELESS 868 MHz WEATHER STATION WIRELESS 868 MHz WEATHER STATION Instructions Manual INTRODUCTION: Congratulations on purchasing this Weather Station with wireless 868 MHz transmission of outdoor temperature and display of indoor temperature,

More information

OPERATING INSTRUCTIONS Digital weekly time switch

OPERATING INSTRUCTIONS Digital weekly time switch OPERATING INSTRUCTIONS Digital weekly time switch 1 Explanation of display and control buttons One-channel timer A B Two-channel timer 1.1 Control buttons i Set time and day of the week e Manual switching

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space

Wireless wall transmitter, 1-gang with inscription space, Wireless wall transmitter, 3-gang with inscription space Wireless wall transmitter, 1-gang with inscription space Order No. : 5331.. Wireless wall Order No. : 5333.. Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected

More information

DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz)

DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz) DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz) User Manual Order code: MIC78 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before

More information

Tempus Digital Digital Astro-Timer D GB CZ BZT28A71. Installation and Operating Manual BZT28A71

Tempus Digital Digital Astro-Timer D GB CZ BZT28A71. Installation and Operating Manual BZT28A71 2 8mm 310366 Tempus Digital Digital Astro-Timer BZT28A71 0,5mm - 2,5mm 2 0 6 12 18 24 L N 230-240V~ 50-60Hz R 10a -30T Installation and Operating Manual MENU OK BTZ28A71 D CZ PL HR 16(10)A 250V~ 1 2 3

More information

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems WLL 0(T) Photoelectric switches Photoelectric switches with fibre-optic cable Proximity mode Photoelectric switches with fibre-optic cable Through-beam mode Photoelectric switches WLL 0(T), fibre-optic

More information

IEM 200 R UHF receiver. user manual

IEM 200 R UHF receiver. user manual IEM 200 R UHF receiver user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 17.11.2015,

More information

free solo HT UHF wireless system user manual

free solo HT UHF wireless system user manual free solo HT UHF wireless system user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 22.01.2013 Table

More information

Level Switch NRS 2-50 NRS Original Installation Instructions English

Level Switch NRS 2-50 NRS Original Installation Instructions English Level Switch NRS 2-50 NRS 2-51 EN English Original Installation Instructions 819179-03 1 Contents Important Notes Page Usage for the intended purpose...4 Function...4 Safety note...4 Directives and Standards

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

Sentry Digital Timers

Sentry Digital Timers Sentry Digital Timers 0733s S4 Contents 1. Safety precautions 2. General rmation 3. DIN rail Installation 4. Display Layout. Programming 6. Technical Data 7. Guarantee 2 Safety precautions The connection

More information

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50

GESTRA Steam Systems LRS English. Installation & Operating Instructions Conductivity Switch LRS 1-50 GESTRA Steam Systems LRS 1-50 EN English Installation & Operating Instructions 819223-02 Conductivity Switch LRS 1-50 Contents Important notes Page Usage for the intended purpose...4 Function...4 Safety

More information

Power Supply. Note: you can t charge the standard battery or rechargeable battery via Mains operation. 2

Power Supply. Note: you can t charge the standard battery or rechargeable battery via Mains operation. 2 MMR-77 GB Version 1 1 1 2 3 4 5 6 7 8 9 Controls AM/FM band switch Emergency buzzer Dynamo power AM/FM band indicator Tuning LED indicator Charging LED indicator Illumination button Dial scale Dial pointer

More information

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available. Fig.: 230 V version Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available. Installation, connection and programming instructions

More information

Sauter Components

Sauter Components R 44.488/ QRK 0: Heating controller Used in conjunction with temperature detectors (Ni000) and appropriate control valves for heating and domestic-hot-water control (with various configurations), mainly

More information

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Technical data. Safety notes.  T3-LR24A-SR en v Subject to changes 1 / 2 echnical data sheet LR4A-SR Modulating rotary actuator for and -way control ball valves orque Nm Nominal voltage AC/DC 4 V Control: Modulating DC... V Position feedback: DC... V echnical data Safety notes

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules SESOTEC MB Sensor Modules 110042808 SESOTEC MB HF1 COM1 110051733 SESOTEC MB HF1 DAI 110059684 SESOTEC MB HF2 COM1 Function description With the new HF sensor modules, you,

More information

Model: 5001 INSTALLATION AND OPERATING INSTRUCTIONS

Model: 5001 INSTALLATION AND OPERATING INSTRUCTIONS Model: 5001 INSTALLATI AND OPERATING INSTRUCTIS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATI INSTRUCTIS DO NOT ATTEMPT TO INSTALL OR OPERATE INTRODUCTI This SKYTECH remote control system was developed

More information

Operation. 1 of 14. Serial number label

Operation. 1 of 14. Serial number label Telecody Keypad Transmitter (US) WARNING There is a possible risk of injury or death if safety instructions will not be observed. Please read and follow all instructions in this manual as well as the information

More information

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R

WLL 170 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC. Dimensional drawing R1.6 2-R WLL 0 Photoelectric switches with fibre-optic cable, red light, manual sensitivity adjustment -- DC 0... 0 mm Through-beam systems Dimensional drawing R. -R. Scanning distance 0... 0 mm. Proximity systems

More information

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions) ENGLISH (Original instructions) INSTRUCTION MANUAL Radio BMR00 WARNING: For your personal safety, READ and UNDERSTAND before using. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Symbols The following show

More information

3301 INSTALLATION AND OPERATING INSTRUCTIONS

3301 INSTALLATION AND OPERATING INSTRUCTIONS DOWN Cover Closed MODE UP Cover Open DOWN MODE TIMER TIME SET UP 3301 INSTALLATION AND OPERATING INSTRUCTIONS INTRODUCTION This SKYTECH remote control system was developed to provide a safe, reliable,

More information

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application STR-LCF Electronic Fan Coil Thermostat (Flush mounting) Datasheet Subject to technical alteration Issue date: 28.2.217 Application The fan coil room thermostat has been designed for individual control

More information

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES CM927 can be installed without disrupting your room décor as no wiring connection is required between the room unit and the boiler Attractive, slim, ultra-modern

More information

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions)

Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions) EN Wireless Receiver E28Q Wireless Receiver E28Q Mounting and Operating Instructions (Original operating instructions) Always read before initial operation! 28509900_E28Q_EN_2012-05-08.doc 1 / 12 1 Data

More information

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional B-Tronic EasyControl EC5401B en Assembly and Operating Instructions Wall/hand-held transmitter, 1-channel, bidirectional Important information for: Fitters / Electricians / Users Please forward accordingly!

More information

200 RTH OFF ON IN OUT ALARM RESET

200 RTH OFF ON IN OUT ALARM RESET 200 RTH OFF ON IN OUT ALARM RESET EN OWNER S MANU AL www.auraton.pl 2 3 Thank you for purchasing the modern temperature controller based on an advanced microprocessor. AURATON 200 RTH LCD FrostGuard function:

More information

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 3B SCIENTIFIC PHYSICS Analogue Multimeter Escola 100 1013527 Instruction sheet 12/15 SD/JS 1 Display with mirror scale 2 Slotted screw for zero calibration 3 Calibration trimmer for setting centre zero

More information

Bedienungsanleitung. Instructions d utilisation Emetteur HS 1 BiSecur / HS 4 BiSecur. Bedieningshandleiding

Bedienungsanleitung. Instructions d utilisation Emetteur HS 1 BiSecur / HS 4 BiSecur. Bedieningshandleiding DE EN FR NL IT ES PT Bedienungsanleitung Handsender HS 1 BiSecur / HS 4 BiSecur Operating instructions Hand transmitter HS 1 BiSecur / HS 4 BiSecur Instructions d utilisation Emetteur HS 1 BiSecur / HS

More information

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION Hol Man Auto Day OPERATING AND INSTALLATION DIGISTAT OPTIMISER - Radio frequency controlled programmable room thermostat with domestic hot water programmer FOR GREENSTAR CDi AND GREENSTAR Si MODELS ALSO

More information

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS INTRODUCTION IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE This remote control system

More information

Energate Foundation Meter Data Collector Installation Guide

Energate Foundation Meter Data Collector Installation Guide Energate Foundation Meter Data Collector Installation Guide The Meter Data Collector works with Foundation s built-in Meter Data Receiver. The collector attaches to the meter provided by your electricity

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

MMR-77CL 中文 GB. Revision 1

MMR-77CL 中文 GB. Revision 1 MMR-77CL 中文 GB Revision 1 Controls 1 2 3 4 5 6 7 8 AM/FM band switch Dynamo power AM/FM band indicator Tuning LED indicator Charging LED indicator Backlight button Dial scale Dial pointer 9 Rotary tuning

More information

Control module 2 circuits AD290. Installation and Service Manual

Control module 2 circuits AD290. Installation and Service Manual EN Control module 2 circuits AD290 Installation and Service Manual 129443-02 Contents 1 Introduction...4 1.1 Symbols used...4 1.2 Abbreviations...4 2 Safety instructions and recommendations...5 2.1 Recommendations...5

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

TR20A120 RE / 02.2012 DE EN FR NL IT ES PT Anleitung für Montage und Betrieb Funk-Codetaster FCT 10 BiSecur Instructions for fitting and operating Radio code switch FCT 10 BiSecur Instructions de montage

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this fancy 868MHz Temperature Station which displays the time, indoor temperature and indoor humidity,

More information

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch Radio Touch Order no.: 2880 xx Operation and installation instructions 1 Safety instructions Electrical equipment must only be installed and assembled by a qualified electrician in accordance with the

More information

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd Digital 7-Day Programmable Timer 4TCD1 Schneider Electric (Australia) Pty Ltd Contact us: clipsal.com/feedback National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56 Installation Instructions

More information

Cat. No. H8861 Model: RCL-S-STAT

Cat. No. H8861 Model: RCL-S-STAT -AAA Cat. No. H8861 Model: RCL-S-STAT INSTALLATION AND OPERATION INSTRUCTIONS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE INTRODUCTION This remote

More information

1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS 1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS, DO NOT ATT TO INSTALL OR OPERATE INTRODUCTION This SKYTECH remote control system was

More information

IEM 100 UHF wireless system. user manual

IEM 100 UHF wireless system. user manual IEM 100 UHF wireless system user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 18.06.2018,

More information

433 MHZ TEMPERATURE STATION Instruction Manual

433 MHZ TEMPERATURE STATION Instruction Manual 433 MHZ TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this innovative 433MHz Temperature Station which displays the time with up to the minute indoor and up to three

More information

H201 中文 GB Version 1

H201 中文 GB Version 1 H201 中文 GB Version 1 Controls 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 LCD Display Preset stations (preset 3 also for tuning step change) Nap timer (Short timer) Power button Band and Time Set button

More information

HORNET Remote Control Systems

HORNET Remote Control Systems HORNET Remote Control Systems Up to 100metres Range 1 3 Button versions 12-30Vdc 0r 230Vac versions Reliable FM Technology Up to four 1000W Relay switches Waterproof Receiver (IP68) Momentary or Latching

More information

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF Installation and service instructions for contractors VIESMANN Vitotrol 3 RF Wireless remote control for one, two or three heating circuits For applicability, see the last page VITOTROL 3 RF 4/212 Please

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing echnical data sheet Rotary actuator LR4A Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage AC/DC 4 V Control: Open/close or -point echnical data Electrical data Nominal voltage

More information

User Guide. Wideband 4-channel Auto Gain-Control Antenna Divider

User Guide. Wideband 4-channel Auto Gain-Control Antenna Divider User Guide AD-708 Wideband 4-channel Auto Gain-Control Antenna Divider All rights reserved. Do not copy or forward without prior approvals MIPRO. Specifications and design subject to change without notice.

More information

Remote Control Outlets Operating Instructions

Remote Control Outlets Operating Instructions Remote Control Outlets Operating Instructions - FOR INDOOR OR OUTDOOR USE - IMPORTANT SAFEGUARDS Signal Word Definitions NOTE: These are general definitions only; all may not pertain to the actual product

More information

24HR/7 DAY YEARLY 4 CHANNEL INSTALLATION & OPERATING (4 MODULE) 16A. DIGITAL TIMESWITCH Cat. No TR644S INSTRUCTIONS

24HR/7 DAY YEARLY 4 CHANNEL INSTALLATION & OPERATING (4 MODULE) 16A. DIGITAL TIMESWITCH Cat. No TR644S INSTRUCTIONS 24HR/7 DAY YEARLY 4 CHANNEL (4 MODULE) 16A DIGITAL TIMESWITCH Cat. No TR644S INSTALLATION & OERATING INSTRUCTIONS 1.0 Description (page 64) 2.0 Features (page 64) 3.0 Application / Installation (page 65)

More information

Operating instructions. Radio weather station

Operating instructions. Radio weather station Operating instructions Radio weather station 0334.. Notes regarding the battery Batteries and button cells do not belong in the hands of children. Contact a doctor immediately if a button cell has been

More information