Contents. Time switches. Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8

Size: px
Start display at page:

Download "Contents. Time switches. Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8"

Transcription

1 Contents Presentation 2 Offer overview 4 Choice table 6 Technical data and catalogue numbers 8 Practical advice 15 A few principles 15 Programming examples 16 Updated: 27/8/03 1

2 Presentation For all sectors of activity Residential. Shops. Schools. Agriculture. Offices. Airports, stations. Factories. A host of applications Bells. Lighting. Heating. Ventilation. Access control. Roller blinds. A range devised specially for your convenience Automatic, simple management of circuit opening and closing. Functions meeting your requirement as closely as possible. Continual upgrading of the range. Generation of more ergonomic time switches E.fm/2 Updated: 27/08/03

3 IHP: programming ergonomics for the residential and tertiary sectors Intuitive, simple, ergonomic and practical. Time savings are guaranteed with the range of programmable time switches. Intuitive programming All programming has been specially devised for simple and convenient use: only 4 keys choice of language and guiding in the menus by key words to create, check, modify or partially or totally delete the program time updating and changeover to winter/summer time: automatic: selection when programming the changeover date (according to geographic area) manually by the user without modification of programs. Unique programming legibility Equipped with a large screen (back-lit for the + version), the IHP switches offer immediate display of: the hour, minutes and day of the week the current operating mode the channel switching status ("On", "Off") the control mode (automatic, override, random or holiday for the + version) operation on mains or battery. Simplified installation Specially devised for contractors, the IHP range is easy to install: direct connection of loads up to 16 A under 250 V tunnel terminals for cables up to 6 mm 2 easy terminal clamping thanks to flush screws allowing use of an insulated screwdriver installation leaflet always available in the device thanks to the built-in leaflet holder slot (except for IHP 1c 18 mm programmable time switch and IHP + 1c 18 mm) a swivel, sealable cover. Updated: 27/08/ E.fm/3

4 Presentation Offer overview 5 programming type 60 minute timetable to program a repetitive cycle. 24 hour daily to program one cycle over a day. 7 day weekly to program one cycle over a week. 7 day weekly with dated days to program one cycle over a week and special cycles for specific days (public holidays, etc.). 60 minutes, 24 hours, 7 days, 7 days with dated days for all programming types. The intuitive switches: 4 keys and a large screen IHP 1c. IHP 2c. IHP + 1c. IHP + 2c. IHP DCF 1c. IHP 1c 18 mm. IHP + 1c 18 mm. 7 J 24 The special switches: 3 or 4 channels and 128 memory spaces IHP 24h and 7d 3c. IHP 24h and 7d 4c. 7 J The annual switches: 7 days + dated days IHP 1c annual. IHP 2c annual. 7 J The multifunctional switch: 60 minutes, 24 hours, 7 days, 7 days + dated days 60 min ITM 4C-6E J 7 J 92045E.fm/4 Updated: 27/08/03

5 The compact switches: 18 mm IHP 1c 18 mm. IHP + 1c 18 mm. IHH 7d 1c ARM. IH 24h 1c ARM. IH 24h 1c SRM. IH 24h 1c (UL). 7 J 24 The classic switches: mechanical 60 min 24 7 J IH 60 min 1c SRM. IH 24h 1c SRM. IH 24h 1c ARM. IH 24h 2c ARM. IHH 7d 1c ARM. IH 7d 1c ARM. IH 24 h + 7d 1+1c ARM. IH 24 h + 7d 1+1c SRM. Updated: 27/08/ E.fm/5

6 Presentation Choice table The time switches control opening and closing of one or more separate circuits according to a programming pre-set by the user: by memorisation of ON and OFF switching operations for the electronic IHP switches by positioning of jumpers or captive segments on a programming dial for the mechanical IH switches. An IHP or IH time switch is chosen according to the following criteria: Time switches Description Number of channels The intuitive switches 4 keys and a large screen Cycle period Minimum time between 2 switching operations Number of switching operations Saving on mains cut off Overall dimensions IHP 1c 1 24 h and/or 7 d 1 min years 5 modules IHP + 1c 1 24 h and/or 7 d 1 sec years 5 modules IHP 2c 2 24 h and/or 7 d 1 min years 5 modules IHP + 2c 2 24 h and/or 7 d 1 sec years 5 modules IHP 1c 18 mm 1 24 h and/or 7 d 1 min years 2 modules IHP + 1c 18 mm 1 24 h and/or 7 d 1 min years 2 modules IHP DCF 1c 1 24 h and/or 7 d 1 sec years 5 modules IHP 1c (UL) 1 24 h and/or 7 d 1 min years 5 modules IHP 2c (UL) 2 24 h and/or 7 d 1 min years 5 modules The special switches 3 or 4 channels and 128 memory spaces IHP 24h and 7d 3c 3 7 d 1 sec years 10 modules IHP 24h and 7d 4c 4 7 d 1 sec years 10 modules The annual switches 7 d + dated days (1) IHP 1c annual 1 7 d + dated days 1 min years 10 modules IHP 2c annual 2 7 d + dated days 1 min years 10 modules The compact switches 18 mm IHP 1c 18 mm 1 24 h and/or 7 d 1 min years 2 modules IHP + 1c 18 mm 1 24 h or 7 d 1 min years 2 modules IHH 7d 1c ARM 1 7 d 2 h 42 on - 42 off 100 h 2 modules IH 24h 1c ARM 1 24 h 15 min. 48 on - 48 off 100 h 2 modules IH 24h 1c SRM 1 24 h 15 min. 48 on - 48 off none 2 modules IH 24h 1c (UL) 1 24 h 15 min. 48 on - 48 off 100 h 2 modules The classic switches mechanical IH 60 min 1c SRM 1 60 min. 1 min 15 s 24 on - 24 off none 6 modules IH 24h 1c SRM 1 24 h 30 min. 24 on - 24 off none 6 modules IH 24h 1c ARM 1 24 h 30 min. 24 on - 24 off 150 h 6 modules IH 24h 2c ARM 2 24 h 30 min. 24 on - 24 off 150 h 6 modules IH 7d 1c ARM 1 7 d 4h 21 on - 21 off 150 h 6 modules IH 24 h + 7d 1+1c ARM h + 7 d 45 min h 16 on -16 off + 7 on -7 off 150 h 6 modules IH 24 h + 7d 1+1c SRM h + 7 d 30 min. + 3 h 24 on-24 off + 28 on-28 off none 12 modules The multifunctional switch ITM 4C-6E 4 60 min., 24 h, 7 d 7 d + dated days 1 sec. 45 time brackets in weekly time programming, 15 time brackets in annual time programming, 20 different pulses in pulse programming 5 years 10 modules (1): programming of dated days allows specific switching operations on certain days (2): pulse programming allows switching operations of a duration less than one minute (adjustable from 1 to 59s); a pulse control always has priority E.fm/6 Updated: 27/08/03

7 Override controls: On / Off Output contact (cos ϕ=1) Time changeover (summer/ winter) Back-lighting Random function "Absence for holidays" function Pulse programming (2) Comments Cat. no. On / Off 16 A changeover switch auto On / Off 16 A changeover switch auto On / Off 16 A changeover switch auto On / Off 16 A changeover switch auto On / Off 16 A changeover switch auto On / Off 16 A changeover switch auto On / Off 16 A changeover switch auto random function the IHP DCF is synchronised on the Frankfort transmitter via the ANT DCF antenna, cat. no On / Off 16 A changeover switch auto supply voltage: 120 V CA On / Off 16 A changeover switch auto supply voltage: 120 V CA On / Off 10 A changeover switch manual On / Off 10 A changeover switch manual On / Off 10 A changeover switch auto On / Off 10 A changeover switch auto On / Off 16 A changeover switch auto On / Off 16 A changeover switch auto On / Off 16 A changeover switch manual On / Off 16 A changeover switch manual On / Off 16 A changeover switch manual On / Off 16 A changeover switch manual supply voltage: 120 V CA On 16 A changeover switch manual On 16 A changeover switch manual On 16 A changeover switch manual On 16 A changeover switch manual On 16 A changeover switch manual On 16 A changeover switch manual On 16 A changeover switch manual ON/OFF via an override input or a condition input 2 x 10 A changeover switch 2 x 10 A NO contact auto 4 output channels and 6 condition inputs Updated: 27/08/ E.fm/7

8 Presentation Technical data and catalogue numbers The intuitive switches - 24 h and/or 7 d Electrical data Voltage: 230 V AC ± 10 %. Frequency: 50/60 Hz. Consumption: 6 VA (2 VA for cat. no and 2.5 VA for cat. no and 3 VA for cat. no ). Saving of program and time by lithium battery: lifetime: - 12 years for cat. no , , , 15857, 15830, years for cat. no and years for cat. no back-up time, cumulated mains cut off: - 5 years for cat. no , , , 15830, years for cat. no years for cat. no , and Time accuracy: ± 1 second per day at 20 C cat. no : 1 second on 1 million years thanks to the synchronisation on the DCF Frankfort transmitter signal. Contact rating: Catalogue number , , , , 15857,15830, Under 250 V AC Under 250 V AC (cos ϕ = 1) (cos ϕ = 0,6) 16 A 10 A , A 4 A , Mechanical data Overall dimensions: 5 modules of 9 mm (2 modules for cat. no and ). Weight: 190 g (90 g for cat. no and ). Degree of protection: front face: IP40 terminals: IP20. Operating temperature: - 10 C C. Storage temperature: - 25 C C (- 40 C C for cat. no and ). Specific data for 1 and 2 channel IHP + (cat. no , and ) Manual functions: temporary cancellation of programming for holidays, public holidays, etc. by configuration of the 2 dates - start and end of absence simulation of presence thanks to random operation during ON periods. Pulse functions: programming of pulses adjustable from 1 to 59 seconds (pulse takes priority over switching). Back-lighting of the screen. The IHP + 1c 18 mm cat. no are compatible with the Clario, Librio and Prodis systems (comb busbar connection). Specific data for the IHP DCF (cat. no ) Synchronisation on the Frankfort transmitter DCF 77 signal: automatic on commissioning, then at 1 am, 2 am, 3 am and 4 am every day manual by pressing the IHP keys or after a "reset" displayed on the screen by the letters RC programming of pulses adjustable from 1 to 59 seconds (pulse takes priority over switching). Manual functions: temporary cancellation of programming for holidays, public holidays, etc. by configuration of the 2 dates - start and end of absence simulation of presence thanks to random operation during ON periods. Pulse functions: programming of pulses adjustable from 1 to 59 seconds (pulse takes priority over switching) E.fm/8 Updated: 27/08/03

9 V 50-60Hz -10 T M Res (10) 250V V 50-60Hz -10 T M Res (10) 250V Res Specific data for the ANT DCF antenna (cat. no ) Connection: 1.5 mm 2 5 IHP DCF maximum per antenna maximum distance between the IHP DCF and the antenna: 200 metres. Installation: outside the electrical switchboard, outdoors, under shelter. Operating temperature: - 20 C C. Degree of protection: IP54. Overall dimensions: L x l x H: 70 x 57 x 92 mm. Weight: 135 g. Connection load 12 V L L L N ANT DCF ANT DCF Auto Prog Man RC Off 22: menu ok Auto Prog Man RC Off 22: menu ok Prog On 10:54 menu ok L L N N N N load load load load connection of 5 IHP DCF maximum per antenna , Catalogue numbers Description Number of channels Catalogue number IHP 1c IHP + 1c IHP 2c IHP + 2c IHP 1c 18 mm IHP + 1c 18 mm IHP DCF 1c ANT DCF IHP 1c (UL) (1) IHP 2c (UL) (1) (1): supply voltage: 120 V AC ±10 % Updated: 27/08/ E.fm/9

10 Presentation Technical data and catalogue numbers (cont.) The special switches - 7 d Electrical data Voltage: 230 V AC ± 10 %. Frequency: 50/60 Hz. Consumption: 8,5 VA. Saving program and time by lithium battery: back-up time: 3 years cumulated mains cut off. Time accuracy: ± 1 second per day at 20 C. Contact rating: 10 A under 250 V AC (cos ϕ = 1) 6 A under 250 V AC (cos ϕ = 0,6). Mechanical data Overall dimensions: 10 modules of 9 mm. Weight: 350 g. Degree of protection: front face: IP40 terminals: IP20. Operating temperature: - 10 C C. Storage temperature: - 40 C C. Connection load load load load load load load Catalogue numbers Description Number of channels Catalogue number IHP 24h and 7d 3c IHP 24h and 7d 4c E.fm/10 Updated: 27/08/03

11 The annual switches - 7 d + dated days Electrical data Voltage: 230 V AC ± 10 %. Frequency: 50/60 Hz. Consumption: 3.5 VA. Saving program and time by lithium battery: back-up time: 4 years cumulated mains cut off. Time accuracy: ± 1 second per day at 20 C. Contact rating: 16 A under 250 V AC (cos ϕ = 1) 10 A under 250 V AC (cos ϕ = 0.6). Mechanical data Overall dimensions: 10 modules of 9 mm. Weight: 350 g. Degree of protection: front face: IP40 terminals: IP20. Operating temperature: - 10 C C. Storage temperature: - 40 C C. Connection load load load Catalogue numbers Description Number of channels Catalogue number IHP 1c annual IHP 2c annual Updated: 27/08/ E.fm/11

12 Presentation Technical data and catalogue numbers (cont.) The multifunctional switch - 60 min, 24 h, 7 d, 7 d + dated days Weekly or annual time programming to be distributed over 1, 2, 3 or 4 channels. 6 inputs to condition these functions. A removable memory cartridge to duplicate on another ITM or to save the program created by the contractor Electrical data Voltage: 230 V AC ± 10 %. Frequency: 50 Hz. Consumption: 45 VA. Saving program and time by lithium battery: lifetime: 10 years back-up time: 5 years. Time accuracy: ± 1 second per day at 20 C. Contact rating: 10 A under 250 V AC (cos ϕ = 1) 6 A under 250 V AC (cos ϕ = 0.6). Mechanical data Overall dimensions: 10 modules of 9 mm. Weight: 290 g. Degree of protection: front face: IP40 terminals: IP20. Operating temperature: - 5 C C. Storage temperature: - 25 C C. Accessory: removable memory cartridge. Connection L N (switch, pushbutton, light sensitive switch, thermostat, motion control switch, ect...) L N V~ 50Hz = EntrØes / Inputs 230V~ 6 x 230 V AC inputs menu OK - + C1...C4 Canaux / Channels 10A / 230V~ Removable memory cartrdge (cat. no , optional) 4 x 230 V AC 10 A output channels C1 C2 C3 C4 ON OFF C1-C2 C3-C4 Load (lamp, small motor, bell, luminous sign, ect.) L N L N L N L N! Preferably relay your load with a contactor. Catalogue numbers Description Number of channels Catalogue number ITM 4C-6E Memory cartridge E.fm/12 Updated: 27/08/03

13 Res The compact switches - 24 h and/or 7 d , Electrical data Voltage: 230 V AC ± 10 %. Frequency: 50/60 Hz. Consommation: 2.5 VA (3 VA for cat. no ). Saving program and time for cat. no , 15336, 15349, and : lifetime: 10 years back-up time, cumulated mains cut off: - 3 years for cat. no et years for cat. no , 15335, 15336, Time accuracy: ± 1 second per day at 20 C. Contact rating: Catalogue number Mechanical data Programming by captive segments for cat. no Overall dimensions: 2 modules of 9 mm. Weight: 90 g. Degree of protection: front face: IP40 terminals: IP20. Operating temperature: - 10 C C. Storage temperature: - 40 C C (- 25 C C for cat. no ). Specific data for the IHP + 1c 18 mm (cat. no ) Manual functions: temporary cancellation of programming for holidays, public holidays, by configuration of the 2 dates - start and end of absence simulation of presence thanks to random operation during ON periods. Pulse functions: programming of pulses adjustable from 1 to 59 seconds (pulse takes priority over switching). Back-lighting of the screen. The IHP + 1c 18 mm cat. no are compatible with the Clario, Librio and Prodis systems (comb busbar connection). Connection under 250 V AC (cos ϕ = 1) , A 4 A 15331, 15335, 15336, A 4 A under 250 V AC (cos ϕ = 0,6) L N Prog On 10:54 menu ok load load 15331, 15335, et , Catalogue numbers Description Number of channels Power reserve Catalogue number IHP 1c 18 mm 1 3 years IHP + 1c 18 mm 1 3 years IHH 7d 1c ARM h IH 24h 1c SRM 1 none IH 24h 1c ARM h IH 24h 1c (UL) h (1) (1): supply voltage: 120 V AC ± 10 % Updated: 27/08/ E.fm/13

14 Presentation Technical data and catalogue numbers (cont.) The classic switches - 60 min, 24 h, 7 d Electrical data Voltage: 230 V AC ± 10 %. Frequency: 50/60 Hz (50 Hz for cat. no ). Consumption: 2.5 VA (1 VA for cat. no ). Time accuracy: ± 1 second per day at 20 C. Contact rating: Catalogue number under 250 V AC (cos ϕ = 1) A 4 A A 2,5 A under 250 V AC (cos ϕ = 0,6) Mechanical data Programming: by jumpers (supplied): IH catalogue number Number of jumpers supplied red + 4 green + 2 white yellow (24 h) 12 blue + 2 red (7 white) blue + 7 red by captive segments for the other catalogue numbers. Overall dimensions: 6 modules of 9 mm (12 modules for cat. no ). Weight: 135 g (210 g for cat. no ). Degree of protection: front face: IP40 terminals: IP20. Operating temperature: - 10 C C. Storage temperature: -40 C +85 C (-25 C +70 C for cat. no ). Accessories for cat. no , and 15367: the additional jumpers are used to program a larger number of sequences. Connection Catalogue numbers Description Number of channels Power reserve Catalogue number IH 60 min 1c SRM 1 none IH 24h 1c SRM 1 none IH 24h 1c ARM h IH 24h 2c ARM h IH 7d 1c ARM h IH 24h + 7d 1+1c ARM h IH 24h + 7d 1+1c SRM 1+1 none Accessories Additional jumpers (1 bag containing: 5 red, 5 green, 5 white, 5 yellow) E.fm/14 Updated: 27/08/03

15 Practical advice A few principles Programming principle For the IHP switches, this consists of memorising the days and times of the required switching operations. For the IH - IHH switches, this is performed by positioning captive segments or jumpers on a switching dial. Example Controlling an air conditionner in a hairdressing salon: Monday (1) Tuesday Wednesday Thursday (2) etc. ON n 1 08 h h h 30 switch on OFF n 1 12 h h 00 switch off ON n 2 13 h h 30 switch on OFF n 2 20 h h h 00 switch off (1) closed on Mondays (2) non-stop Programming by copying or blocks Whenever identical switching operations are found at the same times, several days in the week, this function lets you program these operations once only. In this case a single switching operation is used. If this function is used wisely, the number of possible switching operations can be greatly increased. Example: Monday Tuesday Wednesday Thursday Friday ON n 1 10 h h 00 switch on OFF n 1 18 h h h 00 switch off 1 switching operation 1 switching operation Number of switching operations Cat. no. Number of switching operations IHP 1c IHP + 1c IHP DCF 1c IHP 2c IHP + 2c IHP 24h and 7d 3c IHP 24h and 7d 4c IHP 1c annual IHP 2c annual IHP 18 mm 1c IHP + 1c 18 mm ITM 4C-6E time brackets in weekly time programming, 15 time brackets in annual time programming and 20 different pulses in pulse programming IHP 1c (UL) IHP 2c (UL) IH 7d 1c ARM on / 42 off IH 24h 1c ARM on - 48 off IH 24h 1c SRM on - 48 off IH 24h 1c (UL) on - 48 off IH 60 min 1c SRM on - 24 off IH 24h 1c SRM on - 24 off IH 24h 1c ARM on - 24 off IH 24h 2c ARM on - 24 off IH 7d 1c ARM on - 21 off IH 24 h + 7 d 1+1c ARM on - 16 off + 7 on - 7 off IH 24 h + 7 d 1+1c SRM on - 24 off + 28 on - 28 off Saving on mains cut off For IHP switches equipped with this function, a lithium battery is used for saving. The program, date and time are preserved. Switching operations are not performed. Updated: 27/08/ E.fm/15

16 Practical advice Programming examples 60 min time programming Lets you control starting and stopping of a group of loads according to a cycle that is repeated every 60 minutes. Example Controlling automatic watering: ON n 1 OFF n 1 ON n 2 OFF n 2 2 min 30 s 5 min 25 min 37 min 30 s Relevant catalogue number IH 1c: h daily programming. Lets you control starting and stopping of one or two groups of loads according to a daily cycle that is repeated, in identical manner, every day of the week. Example Controlling a door of a block of flats: from 8 am to 7.30 pm: contact on ON, free access from 7.30 pm to 8 am the next day: contact on OFF, access by confidential code every day of the week: From Monday to Sunday ON n 1 8 am OFF n pm Relevant catalogue numbers IH 1c: 16364, 15365, 15336, 15335, 15366, IH 2c: IHP 1c 18 mm: IHP + 1c 18 mm: IHP DCF 1c: IHP 1c: , , IHP 2c: , , ITM 4C-6E: d weekly programming.j Lets you control starting and stopping of one to 4 groups of loads according to a weekly cycle, that can be different each day, repeated each week. Example Controlling the lighting of a shop window: Monday Tuesday Wednesday Thursday Friday Saturday Sunday ON n 1 09 h h h 00 OFF n 1 12 h h 00 ON n 2 14 h h 00 OFF n 2 20 h h h 00 ON n 3 8 h 30 8 h 30 OFF n 3 12 h h 30 ON n 4 14 h h 30 OFF n 4 21 h h 00 Relevant catalogue numbers IH 1c: 15367, 15331, 15366, IHP 1c: , , 16355, IHP 2c: , , 16356, IHP 1c 18 mm: IHP + 1c 18 mm: IHP DCF 1c: IHP 3c: IHP 4c: ITM 4C-6E: E.fm/16 Updated: 27/08/03

17 Pulse programming. Lets you control by pulses (adjustable from 1 to 59 s) one to four groups of loads (pulse relays, bells, etc.). Example Automatic controlling of bells, lighting and distribution of food: bells sounding the resumption and finish of work (channel 1), lighting of premises (channel 2), feeding fish in the aquarium (channel 3): Monday Tuesday Wednesday Thursday Friday Saturday Sunday Canal 1 : sonnerie (ordre impulsionnel de 20 s) ON 08 h h h h h h 00 duration 20 sec 20 sec 20 sec 20 sec 20 sec 20 sec ON 12 h h h h h h 00 duration 20 sec 20 sec 20 sec 20 sec 20 sec 20 sec ON 14 h h h h h 00 duration 20 sec 20 sec 20 sec 20 sec 20 sec ON 18 h h h h h 00 duration 20 sec 20 sec 20 sec 20 sec 20 sec Channel 2: lighting (latched order) ON 07 h h h h h h 30 OFF 18 h h h h h h 30 Channel 3: aquarium (15 s pulse order) ON 10 h h h h 00 duration 15 sec 15 sec 15 sec 15 sec Programming Programming of a pulse takes up 2 memory spaces. Combination of the two order types (pulse and latched) is possible on the same channel. Relevant catalogue numbers IHP + 1c: IHP + 1c 18 mm: IHP DCF 1c: IHP + 2c: IHP 3c: IHP 4c: ITM 4C-6E: Updated: 27/08/ E.fm/17

18 Practical advice Programming examples (cont.) Programming special days. Lets you create special programs for dated days. Example Controlling lighting and heating in a school: basic programming: program lighting (channel 1) and heating (channel 2): Channel 1: lighting Monday Tuesday Wednesday Thursday Friday Saturday Sunday ON 07 h h h h h 00 OFF 20 h h h h h 00 Channel 2: heating ON 06 h h h h h 00 OFF 18 h h h h h 00 dated programming: periods of non-operation, school holidays, etc., Just memorise an OFF at the start and another OFF at the end of each period of absence: Holidays winter spring summer autumn end of year Channel 1 : lighting OFF date 20 feb. 17-apr 07-july 23 oct. 18 dec. time 12 h h h h h 00 OFF date 08-march 03-may 9 sept. 2 nov. 4 jan. time 01 h h h h h 00 Channel 2 : heating OFF date 20 feb. 17-apr 23 oct. 18 dec. time 12 h h h h 00 OFF date 08-march 03-may 2 nov. 4 jan. time 01 h h h h 00 Relevant catalogue numbers IHP 1c: IHP 2c: IHP DCF 1c: IHP 3c: IHP 4c: ITM 4C-6E: IHP + 1c: IHP + 2c: IHP + 1c 18 mm: Additional information Dimensions: page E.fm/18 Updated: 27/08/03

1. Contents Page. 2. Assembly, putting into operation, connection Control elements Display Factory setting Changing settings 6

1. Contents Page. 2. Assembly, putting into operation, connection Control elements Display Factory setting Changing settings 6 1. Contents 2 1. Contents Page 2. Assembly, putting into operation, connection 3 3. Control elements 4 4. Display 4 5. Factory setting 5 6. Changing settings 6 6.1 Time and day of the week 6 6.2 Calendar

More information

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC

TR TR 641 top TR 642 top TR 644 top TR 641 top2 RC TR 642 top2 RC TR 644 top2 RC 2 2 309 429 01 TR TR 641 top2 641 0 100 TR 642 top2 642 0 100 TR 644 top2 644 0 100 TR 641 top2 RC 641 0 300 TR 642 top2 RC 642 0 300 TR 644 top2 RC 644 0 300 Installation and operating instructions Digital

More information

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches Weekly Timer Timer Provides Prompted Programming, Flexibility in Programs Within the Week AM/PM display 24 program steps A different program possible each day Over midnight settings possible Two independent

More information

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2

E N SHT-1 SHT-1/2 SHT-3 SHT-3/2 Digital time switch E N SHT-1 SHT-1/2 SHT-3 SHT-3/2 Content Symbol, Connection... 3 Warning... Characteristics... 5 Technical parameters... 6 Versions of time switches, Load... 7 Description... 8-9 Control...

More information

MANUAL. PT Series 365 Day Annual Timer. Tel:

MANUAL. PT Series 365 Day Annual Timer.   Tel: MANUAL PT Series 365 Day Annual Timer www.belltimers.com Tel: 1-888-327-8463 info@belltimers.com Table of Contents: Introduction Features Specifications Overview Installation Function Keys Relay Operation

More information

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF

Overview per day of the programmed switching times 5 = Friday. Channel statuses / OFF 310 785 01 TR 611 top TERMINA 1-channel 7 day timer According to version Preprogrammed with the current time and summer/ winter norm time Safety Information The connection and installation of electrical

More information

Sentry Digital Timers

Sentry Digital Timers Sentry Digital Timers 0733s S4 Contents 1. Safety precautions 2. General rmation 3. DIN rail Installation 4. Display Layout. Programming 6. Technical Data 7. Guarantee 2 Safety precautions The connection

More information

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units 1 Time Scheduling RDU-4/TS - Description of Control Operation The temperature control and time scheduling for the building space is

More information

TM Analogic. Serie TM. Cod. rev

TM Analogic. Serie TM. Cod. rev TM Digital TM Digital-B TM Analogic Serie TM. Cod. rev. 1.0 1 CONTENTS 1 First of all Page 2 2 Installation Page 4 3 Setting and Operation Page 7 4 Maintenance Page 10 1 FIRST OF ALL - WARNINGS Check the

More information

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S.

TR 612 S. Bedienungsanleitung (Seite 2 19) Operating Instructions (pag ) Mode d emploi (page 38 55) Bruksanvisning (S. 310 415 TR 612 S Bedienungsanleitung (Seite 2 19) Operating Instructions (pag. 20 37) Mode d emploi (page 38 55) Bruksanvisning (S. 56 73) 2-Channel Time Switch EIB 8 GB 7 9 10 6 1 2 11 5 4 3 2 1 1 2 3

More information

Radio-control universal dimmer (built-in type) Installation Instructions

Radio-control universal dimmer (built-in type) Installation Instructions 2-Channel Time Switch Order no.: 1073 00 1 Programming / checking mode 2 Button for setting current time 3 Button for setting day of the week 4 Days of the week (1 = Mon, 2 = Tues, 7 = Sun) 5 Cursor t

More information

24HR/7 DAY YEARLY 4 CHANNEL INSTALLATION & OPERATING (4 MODULE) 16A. DIGITAL TIMESWITCH Cat. No TR644S INSTRUCTIONS

24HR/7 DAY YEARLY 4 CHANNEL INSTALLATION & OPERATING (4 MODULE) 16A. DIGITAL TIMESWITCH Cat. No TR644S INSTRUCTIONS 24HR/7 DAY YEARLY 4 CHANNEL (4 MODULE) 16A DIGITAL TIMESWITCH Cat. No TR644S INSTALLATION & OERATING INSTRUCTIONS 1.0 Description (page 64) 2.0 Features (page 64) 3.0 Application / Installation (page 65)

More information

SA-027HQ 365-Day Annual Timer

SA-027HQ 365-Day Annual Timer SA-027HQ 365-Day Annual Timer Manual Two N.O. or N.C. Form C relays, 10A@14VDC Each relay can be programmed for 50 events, for a total of 100 individual programmable events 10 Programmable holidays The

More information

INSTAT 868 Radio Frequency Single-Room Controls

INSTAT 868 Radio Frequency Single-Room Controls INSTAT 868 Radio Frequency Single-Room Controls Easy to operate wireless application HEATING People Performance Products Climate Controls Europe An Invensys company Radio Frequency Controls Single-room

More information

Modular Devices - Indicators and Push Buttons

Modular Devices - Indicators and Push Buttons Modular Devices - Indicators and Push Buttons The new range of indicator lights and push buttons replaces and expands upon the whole SV range and is composed of the following three families Indicator Lights

More information

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS

OWNERS MANUAL FOR STERLING SERIES CONTROLLERS OWNERS MANUAL FOR STERLING SERIES CONTROLLERS 24950 AVENUE KEARNY, VALENCIA, CALIFORNIA 91355-2142 PHONE (661) 257-3533 FAX (661) 257-9472 TABLE OF CONTENTS Selecting the Location for the Controller...3

More information

16-Channel Yearly Time Switch TR 648 S DCF

16-Channel Yearly Time Switch TR 648 S DCF 16-Channel Yearly Time Switch TR 648 S DCF Illustration 1 : TR 648 S DCF TR 648 S DCF EIB 648 9 201 DCF 77 Antenna 907 0 271 Obelisk 2.0 Programming set 907 0 305 Obelisk 2.1 Software 931 0 961 Page 1

More information

LK Wireless Room Control Cq

LK Wireless Room Control Cq LK Wireless Room Control Cq Description LK Wireless Room Control Cq consists of a LK Room Thermostat Cq-n (transmitter) and a LK Receiver Unit Cq 8 (8 channel receiver unit). The range also includes a

More information

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights 1- GENERAL DESCRIPTION Electronic for the remote control of tubular motors for roller blinds, rolling shutters, doors with limit switch inside or outside the motor, radio receiver section with transmitter

More information

RX-100. Drahtloser Programmierbarber Thermostat Betriebs-, Reinigungsund Wartungsanleitung für den INSTALLATEUR und den BENUTZER

RX-100. Drahtloser Programmierbarber Thermostat Betriebs-, Reinigungsund Wartungsanleitung für den INSTALLATEUR und den BENUTZER RX-100 E Termostato Inalámbrico Programable Instrucciones de Instalación, Montaje y Funcionamiento para el INSTALADOR Y USUARIO GB Wireless Programmable Thermostat Installation, Assembly and Operating

More information

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd

4TCD1. Digital 7-Day Programmable Timer. Installation Instructions. Tel Fax Schneider Electric (Australia) Pty Ltd Digital 7-Day Programmable Timer 4TCD1 Schneider Electric (Australia) Pty Ltd Contact us: clipsal.com/feedback National Customer Care Enquiries: Tel 1300 2025 25 Fax 1300 2025 56 Installation Instructions

More information

Motor 1- GENERAL DESCRIPTION

Motor 1- GENERAL DESCRIPTION 1- GENERAL DESCRIPTI TELECO AUTOMATI SRL - Via dell Artigianato, 16-31014 Colle Umberto (TV) ITALY TELEPHE: ++39.0438.388511 FAX: ++39.0438.388536 This document is the property of Teleco Automation Srl

More information

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 OPERATING INSTRUCTIONS ARE ON PAGE 5 RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1 This Programmable Ravenheat R/F controlled room Thermostat RVHT 2, consists of 2 items: a Mobile Transmitter

More information

User Instructions For TopTronic RS-10

User Instructions For TopTronic RS-10 User Instructions For TopTronic RS-0 409ENG-Dec0 Hoval Ltd Northgate Newark Nottinghamshire NG4 JN Phone 066 677 Fax 066 675 Index 409ENG-Dec0 Introduction Introduction... Controls... Display... User instructions

More information

Modular Devices & Connection

Modular Devices & Connection Dimmers, time switches, meters and thermostats are among our varied range of devices, and they can all be perfectly housed in our expansive range of enclosures to tailor a building s energy to an individual

More information

DDC Series Dial Digital Controller INSTALLATION AND OPERATING INSTRUCTIONS

DDC Series Dial Digital Controller INSTALLATION AND OPERATING INSTRUCTIONS DDC Series Dial Digital Controller INSTALLATION AND OPERATING INSTRUCTIONS Thank you for choosing the Toro DDC (Digital Dial Controller) irrigation controller. The DDC incorporates the lates programming

More information

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min Weekly Time Switch H5S Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application

More information

RN-16TM LIGHT-SENSITIVE MULTIFUNCTIONAL DAILY-WEEKLY TIMER SERVICE MANUAL. NOVATEK-ELECTRO LTD Research-and-Manufacture Company

RN-16TM LIGHT-SENSITIVE MULTIFUNCTIONAL DAILY-WEEKLY TIMER SERVICE MANUAL. NOVATEK-ELECTRO LTD Research-and-Manufacture Company LTD Research-and-Manufacture Company RN-16TM LIGHT-SENSITIVE MULTIFUNCTIONAL DAILY-WEEKLY TIMER SERVICE MANUAL www.novatek-electro.com - 2-1 APPLICATION Multifunctional relay RN-16TM (hereinafter RN-16TM)

More information

Silent Gliss. Switches and Controls

Silent Gliss. Switches and Controls Switches and Controls Control System 0450 Radio Control System Product Information For use with all Silent Gliss motors Radio controlled - no wiring from switch to control box Up to 255 house and 255 room

More information

User Manual OFF ON IN OUT ALARM RESET AURATON RTH software ver. F0F

User Manual OFF ON IN OUT ALARM RESET AURATON RTH software ver. F0F www.auraton.pl User Manual software ver. F0F OFF ON IN OUT ALARM RESET AURATON RTH Thank you for purchasing this modern, advanced, microprocessor-based temperature regulator AURATON 2025 / AURATON 2025

More information

OPERATING INSTRUCTIONS Digital weekly time switch

OPERATING INSTRUCTIONS Digital weekly time switch OPERATING INSTRUCTIONS Digital weekly time switch 1 Explanation of display and control buttons One-channel timer A B Two-channel timer 1.1 Control buttons i Set time and day of the week e Manual switching

More information

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators Thermostat P Thermostats Electronic room thermostat with clock for thermal actuators IMI HEIMEIER / Thermostats & Actuators / Thermostat P Thermostat P The Thermostat P room temperature controller is used

More information

User Manual Master Clock WDP-Y2/Y4/Y8

User Manual Master Clock WDP-Y2/Y4/Y8 User Manual Page: 1 o f 51 User Manual Master Clock WDP-Y2/Y4/Y8 User Manual Page: 2 o f 51 List of contents TECHNICAL SPECIFICATIONS...3 GENERAL DESCRIPTION...4 INSTALLATION...5 PROGRAMMING...6 GENERAL...6

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

Modbus Integration Integration for Modbus Functionality for VT8300 Series

Modbus Integration Integration for Modbus Functionality for VT8300 Series Modbus Integration Integration for Modbus Functionality for VT8300 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS

More information

SPRING. FALL There will be no classes Wyndham Championship Week (August 13-19) CAMPS. Visit us online at: Summer. Winter

SPRING. FALL There will be no classes Wyndham Championship Week (August 13-19) CAMPS. Visit us online at: Summer. Winter PLAYer Session 1: Mondays (April 9 - May 14) or Wednesdays (April 11 - May 16) PLAYer Session 2: Mondays (May 21 June 25 Makeup) or Wednesdays (May 23 June 27) Par Session 1: Mondays (April 9 - May 14)

More information

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters RI-D440 Three Phase easywire Multifunction DIN Rail Energy Meter Four module DIN rail mounted Energy pulse LED 330mV Input from easywire CTs (or -/1A and -/5A current transformer input with TAS-SCTEWA

More information

Radio technology for home automation

Radio technology for home automation Radio technology for home automation garage door operators Forget the hassle of having to get out of the car to open or close the garage door by hand. At the touch of the button on your SOMMER transmitter,

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

COD GB / 1.0 RBAND/UMS - RBAND/CSM

COD GB / 1.0 RBAND/UMS - RBAND/CSM INTRODUCTION DESCRIPTION The RadioBand system is designed of Industrial, Commercial and Domestic door and gate applications where a safety edge is used. The system provides a wireless system replacing

More information

Wireless Control Systems

Wireless Control Systems Wireless Control Systems Leading the way in intelligent automation contents Range Overview Typical Installations Transmitters Combined Modules Receivers Accessories Programming Switching & Dimmer Functions

More information

DIN Rail Time & Twilight Switches

DIN Rail Time & Twilight Switches DIN Rail & Switches guard Limited, Victory Park, 00 Edgware Road, London NW ND. www.timeguard.com The New Generation of Analogue & Multi-Channel TR top Switches Section Overview Section Overview switches

More information

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2)

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2) INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2) Copyright Lencore Acoustics Corp. All rights reserved. April 2000 CONTENTS Introduction 3 Display 3 Keyboard 4 Installation 4 Set Up 4

More information

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID

MID. RI-F300 Series. easywire Single and Three Phase Multifunction Energy Meter (MID Certified) MID Telephone : 44 (0) 1245 428500 RIF300 Series MID easywire Single and Three Phase Multifunction Energy Meter (MID Certified) DI 96 panel mounted 1A Input from easywire CTs Single phase or three phase network

More information

Silent Gliss. Switches and Controls

Silent Gliss. Switches and Controls Switches and Controls Application Chart Radio Control System 0450 Radio Control System 9940 Motor Number Fixed Switch (Hard wired) Hand Held Remotes Wall Switches Move Server Set Hand Held Remotes Wall

More information

ATP Time Switch

ATP Time Switch ATP1006-2 Time Switch (The time switch timing can be set second.) 1. Function and Scope ATP1006-2 time switch (hereinafter referred to as time switch ) is applicable for regularly controlling switch-on

More information

NRT 105: Electronic fan-coil controller, equiflex

NRT 105: Electronic fan-coil controller, equiflex Product data sheet 4.04 R 105: Electronic fan-coil controller, equiflex How energy efficiency is improved ECO Meter for displaying the current energy consumption and digital input for the change-over between

More information

Marantec bi linked Radio Accessories Service

Marantec bi linked Radio Accessories Service Marantec bi linked Radio Accessories 1 45 Service 2015.08 Impressions transmitters 2 45 Service 2015.08 Impressions wall controls 3 45 Service 2015.08 bi linked technology Simple encoding (e. g. Multi-Bit)

More information

* _Ver.1* GP8 Radio CPL Radio DRIVER Energy manager

* _Ver.1* GP8 Radio CPL Radio DRIVER Energy manager GP8 Radio CPL Radio DRIVER Energy manager Delta Dore hereby declares that the equipment complies with the essential requirements and other relevant provisions of the R&TTE Directive 1999/5/EC The EC declaration

More information

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Radiocontrol F. Floor Heating Controller Radio control system for floor heating Radiocontrol F Floor Heating Controller Radio control system for floor heating IMI HEIMEIER / Floor Heating Control / Radiocontrol F Radiocontrol F The Radiocontrol F radio control system for controlling

More information

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web:  - Key features: True power OFF-delay up to minutes No external control switch necessary Available with reset inputs Mountable in sockets or flush panel Specifications Operation UL, c-ul Listed File No. E55996

More information

V22 Thermostat N515/R00( )

V22 Thermostat N515/R00( ) V22 Thermostat N515/R00(02.10.12) 2 USER GUIDE GB RF Digital programmable Thermostat 3-59 3 IMPORTANT! Before starting work the installer should carefully read this Installation & Operation Manual, and

More information

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed)

itl impulse relays IEC/EN itls: IEC/EN itls b Allows remote indication of its operating state (open/closed) DB123399 DB116619 Country approval pictograms itl, itli, itls, itlc, itlm IEC/EN 60669-2-2 itls: IEC/EN 60947-5-1 Impulse relays B106126-34 B106128-34 itl b The impulse relays are used to control, by means

More information

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION Hol Man Auto Day OPERATING AND INSTALLATION DIGISTAT OPTIMISER - Radio frequency controlled programmable room thermostat with domestic hot water programmer FOR GREENSTAR CDi AND GREENSTAR Si MODELS ALSO

More information

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature Temperature control: Feel good at any time of year Room thermostats Heating time switches Excellent products

More information

LIGHTING CONTROL PANEL

LIGHTING CONTROL PANEL LIGHTING CONTROL PANEL Installation Guide & User Manual 925 A.E.C. D R IVE, W O O D D A LE, IL 60191 (630) 238-1516 / FA X (630) 860-2934 THIS PAGE INTENTIONALLY LEFT BLANK 2 WARRANTY STATEMENT Automated

More information

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2 Selection guide Count - counters Function Totalising counters Display type Mechanical LCD Font panel dimensions (h x w) in mm 0 x 0 x. 0 x 60 x Number of display digits 6 digits or 6 digits (depending

More information

Network VP TM Satellite User s Guide

Network VP TM Satellite User s Guide Network VP TM 2.00 Satellite User s Guide 16 to 64 stations in eight-station increments Field programmable for future upgrades Does not require EPROM(s) replacement Operates as a stand-alone controller

More information

SATURDAY SERIES. $30 Buy-in $5 Entry THE DEEP STACK. $165Buy-in $25Entry $10 Staff Optional. Sunday's 3PM 1/3 NL H'E 3/6 BIG O NL H'E SHOOTOUT SERIES

SATURDAY SERIES. $30 Buy-in $5 Entry THE DEEP STACK. $165Buy-in $25Entry $10 Staff Optional. Sunday's 3PM 1/3 NL H'E 3/6 BIG O NL H'E SHOOTOUT SERIES She Learned to Play at the Casino Club" Casino Club "On Hilltop!" www.reddingpoker.com NOR CAL BEST CASH GAMES!! 1885 Hilltop Dr. Redding, Ca.96002 (530) 221-5015 Gamble Responsibly 1-(800)-Gambler October,

More information

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235 WARRANTY Long Range Systems, Inc. warrants the trap release product against any defects that are due to faulty material or workmanship for a one-year period after the original date of consumer purchase.

More information

2025 RTH 2025 P 2025 OFF ON IN OUT ALARM RESET

2025 RTH 2025 P 2025 OFF ON IN OUT ALARM RESET 2025 RTH 2025 P 2025 OFF ON IN OUT ALARM RESET EN OWNER S MANU AL www.auraton.pl 2 Thank you for purchasing this modern, advanced, microprocessor-based temperature regulator AURATON 2025 / 2025 P / 2025

More information

Automation and control equipment

Automation and control equipment Automation and control equipment D. Latching relays - Latching relays auxiliaries D. Relays - Interface relays D.5 Contactors and override contactors D.6 Electromechanical time switches D.8 Analogue time

More information

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter

PRELIMINARY DATA SHEET. RI-F400 Series. easywire Single and Three Phase Multifunction Energy Meter Telephone : 44 (0) 1245 428500 PRELIMIARY DATA SHEET RIF400 Series easywire Single and Three Phase Multifunction Energy Meter DI 96 panel mounted 330mV Input from easywire CTs (or /1A and /5A current transformer

More information

S449 DIGITAL QUARTZ SUPERHETERODYNE RADIO CONTROLS WITH ROLLING CODES TXQ449400

S449 DIGITAL QUARTZ SUPERHETERODYNE RADIO CONTROLS WITH ROLLING CODES TXQ449400 ELECTRONICS S449 DIGITAL QUARTZ SUPERHETERODYNE RADIO CONTROLS WITH ROLLING CODES 433 MHz FM ROLLING CODE 2 66 CODE COMBINATIONS MEMORISATION VIA RADIO AERIAL ANS400 AVAILABLE CHANNELS 1-4 RANGE 100-150

More information

354B SERIES SHAWNEE II High Speed Predetermining

354B SERIES SHAWNEE II High Speed Predetermining 354B SERIES SHAWNEE II High Speed Predetermining DIMENSIONS INCHES MILLIMETERS The 354B Directly Replaces 354A. A compact version of the 334 counter, the ATC 354B is its exact functional duplicate. Packaged

More information

AURATON 2020 AURATON 2020 TX RX Plus

AURATON 2020 AURATON 2020 TX RX Plus 0 I 31 EN AURATON 2020, AURATON 2020 TX RX Plus AURATON 2020 AURATON 2020 AURATON 2020 TX RX Plus Preliminary notes The manual includes the information on AURATON 2020 and AURATON 2020 TX RX Plus controllers.

More information

05/09/2014

05/09/2014 48 x 48 Digital LCD Timer 814 Part number 88857005 Relay output digital timers LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in

More information

RF Remote Control Unit SEAV

RF Remote Control Unit SEAV RF Remote Control Unit SEAV for LINAK TECH-systems Installation instructions Foreword Dear producer, Thank you for choosing an actuator system from LINAK. LINAK systems consist of high-tech products based

More information

RADIO DRIVER. * _Rev.1* Installation guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones

RADIO DRIVER. * _Rev.1* Installation guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones Installation guide RADIO DRIVER Wireless programmer 6051117 6051118 RADIO DRIVER 610-1 zone RADIO DRIVER 620-2 zones DELTA DORE - Bonnemain - 35270 COMBOURG - FRANCE E-mail: deltadore@deltadore.com 6051119

More information

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2

KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2 KNX manual High-performance switch actuators RM 4 H FIX1 RM 8 H FIX2 4940212 4940217 2018-10-17 Contents 1 Function description 3 2 Operation 4 3 Technical data 5 4 The FIX2 RM 8 H application programme

More information

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC Catalogue 1SFC 266006-en, Edition 3 November 2003 Supersedes Catalogue 1SFC 266006-en, Edition 2 November 2000 Arc Guard System TVOC System units The two units of the are used as below: Approvals 1. with

More information

Rotational speed controller

Rotational speed controller Model number Features Rotational speed monitoring up to khz pre-select value with relay output and LED indicator Multi-range power pack -, -, -wire and NAMUR sensors as well as rotary encoder connectable

More information

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual INTRODUCTION: Congratulations on purchasing this compact 868MHz Temperature Station which displays radio controlled time, date, indoor and outdoor

More information

SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2

SELEKTA SELEKTA 170 top2 D GB F I E P NL PL. Installation and Operating Manual Digital astronomic time switch. SELEKTA 170 top2 2 309 081 03 SELEKTA SELEKTA 170 top2 170 0 100 0,5mm - L N 230-240V~ Installation and Operating Manual Digital astronomic time switch MENU SELEKTA 170 top2 D F I E P NL PL 1 2 3 SELEKTA 170 top2 Correct

More information

Current transformers TI current transformers 0

Current transformers TI current transformers 0 Current transformers TI current transformers 0 056853NMD-2 056854NMD-2 16503. Function Current transformers with a ratio of Ip/5, for measurement devices (ammeters, kilowatt hour meters), load shedders,

More information

Series 354. SHAWNEE II High-Speed Digital Predetermining Counter. The 354B Directly Replaces 354A. COUNTERS PRODUCT HIGHLIGHTS

Series 354. SHAWNEE II High-Speed Digital Predetermining Counter. The 354B Directly Replaces 354A. COUNTERS PRODUCT HIGHLIGHTS Series 354 SHAWNEE II High-Speed Digital Predetermining Counter The 354B Directly Replaces 354A. A compact version of the 334 counter, the ATC 354 is its exact functional duplicate. Packaged in a 72mm

More information

Calendars. Grades 1-3

Calendars. Grades 1-3 Calendars Grades 1-3 A TEACHING RESOURCE FROM... REM 526A ILLUSTRATOR Danny Beck 2003 Copyright by Remedia Publications, Inc. All Rights Reserved. Printed in the U.S.A. The purchase of this unit entitles

More information

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM) PH-BSP WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM) Wireless control unit Two-way radio communication on 433.92 MHz Comfortable solution of room heating Predictive system

More information

Power Meter Series PM3200 Functions and characteristics

Power Meter Series PM3200 Functions and characteristics Functions and characteristics PB108433 This PowerLogic Power meter offers basic to advanced measurement capabilities. With compact size and DIN rail mounting, the PM3200 allows mains and feeders monitoring

More information

Phase control Single function phase control relay - 7.5 mm Control of -phase networks: phase sequence, total phase failure Multi-voltage from x 08 to x 480 V Controls its own supply voltage True RMS measurement

More information

Industriefunkuhren. Technical Manual. System 7001RC. Multi-Source Function ENGLISH. Version:

Industriefunkuhren. Technical Manual. System 7001RC. Multi-Source Function ENGLISH. Version: Industriefunkuhren Technical Manual System 7001RC Multi-Source Function ENGLISH Version: 02.01-29.11.2006 Valid for Control Board 7020RC with FIRMWARE Version: 01.00 and REMOTE-SOFTWARE Version: 00.00

More information

WHEN A PLC IS TOO MUCH, AND SPACE FOR

WHEN A PLC IS TOO MUCH, AND SPACE FOR WHEN A PLC IS TOO MUCH, AND SPACE FOR A RELAY SEQUENCE CIRCUIT IS TOO LITTLE Pattern Selector 59 2.33 66 2.6 70 2.75 No programming required Select from among 15 preset patterns Wiring far simpler than

More information

Radio controllers. Innovation combined with skill and tradition. Intelligent solutions. for all living spaces. Radio-controlled regulation

Radio controllers. Innovation combined with skill and tradition. Intelligent solutions. for all living spaces. Radio-controlled regulation Radio controllers Radio-controlled regulation The radio-controlled temperature regulation of domestic heating systems is ideally suited for both new build and renovation projects. It also offers increased

More information

Silent Gliss. Control Systems

Silent Gliss. Control Systems Control Systems Application Chart Motor Control System Infrared Remote Control d Transmitter Wall Transmitter Radio Receiver / Control Unit DC System 2160 9946, 9948 9068, 9944, 9945 2195 9005, 9006 9946,

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits uminaire-integrated modules SESOTEC MB Sensor Modules 110042808 SESOTEC MB HF1 COM1 110051733 SESOTEC MB HF1 DAI 110059684 SESOTEC MB HF2 COM1 Function description With the new HF sensor modules, you,

More information

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION INSTALLATI INSTRUCTIS Model: RB-G-K10 IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIS BEFORE BEGINNING INSTALLATI The Miller Edge RBand Monitored Gate Edge Transmitter/Receiver system is intended to provide

More information

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation

RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation RAM 712 KNX room thermostat for surface-mounted and flush-mounted installation RAM 712 712 9 200 Version: Dec-10 (subject to change) Page 1 of 65 Contents 1 Functional characteristics... 4 1.1 Operation...

More information

Radio receivers type DB317 and DBR1-M4

Radio receivers type DB317 and DBR1-M4 Radio receivers type DB317 and DBR1-M4 User manual Art no 006176 Technical data DB317 DBR1-M4 Dimensions (WxHxD) 45x75x21 mm 80x80x50 mm Supply Voltage via control panel 12/24 VAC/VDC Current Consumption

More information

CableTroll 2410 PN: /03. User Manual

CableTroll 2410 PN: /03. User Manual CableTroll 2410 PN: 01-2410- 02/03 User Manual UG CT 2410-RMU February 2010 This document describes the installation and configuration of the RMU Fault Indicator Product no: 01-2410- 02/03 Rev. 0.1 (21.01.09)

More information

Quick Reference Guide

Quick Reference Guide Combination Timer S1DC8M3 ELECTRONIC AUTOMATION (P) LTD P. B. # 6414, Yelahanka, Bangalore - 560064 Phones: 0091-080 - 8567561 / 8567562 Fax : 9180-8567129 E-mail : eaplindia@vsnl.com URL : www.eaplindia.com

More information

Technical Description. DCF77 Receiver-Module 4460

Technical Description. DCF77 Receiver-Module 4460 Technical Description DCF77 Receiver-Module 4460 Version 09.02 23.07.2002 COMPANY INFO Safety information The Safety Instructions and Technical Data serve to ensure trouble-free operation and protection

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

200 RTH OFF ON IN OUT ALARM RESET

200 RTH OFF ON IN OUT ALARM RESET 200 RTH OFF ON IN OUT ALARM RESET EN OWNER S MANU AL www.auraton.pl 2 3 Thank you for purchasing the modern temperature controller based on an advanced microprocessor. AURATON 200 RTH LCD FrostGuard function:

More information

Modular Devices and Enclosures

Modular Devices and Enclosures Modular Devices and Enclosures Features Modular contactors for control of motor, heating and lighting applications Digital and Analogue Time Switches for remote command and control of circuits Selectable

More information

Operation Guide 3721

Operation Guide 3721 MA0410-EA Modes and Hand Movement Each press of the B button sounds a confirmation tone and cycles through available modes in the sequence shown below. The watch will revert to the Timekeeping Mode automatically

More information

ATS-01 Ver1.2 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

ATS-01 Ver1.2 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL ATS-01 Ver1.2 AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL Headquarters : No.3, Lane 201, Chien Fu ST., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775 URL :

More information

Compact Preset Counter

Compact Preset Counter signo 721 Compact Preset Counter 1 or 2 presets Prescaler with output for connection of a totalizing counter Large, 5-digit LD display Connection by plug-in screw terminals Variety of programming possibilities

More information

RADIOBAND V3 Programming & Installation Manual

RADIOBAND V3 Programming & Installation Manual RADIOBAND V3 Programming & Installation Manual Radioband V3 User s Manual Introduction The RadioBand system is designed for Automatic Gates, Commercial and Domestic door applications where a safety edge

More information

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips remote control openers security at your fingertips G703 residential gate opener for sliding gates Installation instructions Toll free helpline Please have your serial number and model name available before

More information