ULTRASONIC FLOWMETER < M-Flow>

Size: px
Start display at page:

Download "ULTRASONIC FLOWMETER < M-Flow>"

Transcription

1 ULTRSONIC FLOWMETER < M-Flow> DT SHEET FLR, FLS, FL This meter is a clamp-on type ultrasonic flowmeter for permanent use based on transit time measuring method. This flowmeter is designed to be suitable for machine mounting, thoroughly aimed at small size, light weight and ease of use. This flowmeter can be applied to the pipe size from 5 to 5mm, providing the best cost per performance. FETURES. Ease of use: The parameters necessary for measurement can be configured on the surface of Flow Transmitter s housing case by menu-driven software. The detector is mountable quickly and easily.. Compact and light weight: The adoption of the latest LSI technology and plastic housing has reduced the size and weight of the flow transmitter to one-fifth of our general use flow transmitter.. Superior temperature effect: The adoption of Sound Velocity Measurement System permits almost no influence from fluid temperature and pressure. 4. Quick response: With the use of fast-speed transit time processor, the system cycle is. sec that is applicable to short batch process. 5. Multilingual: The following languages are supported for display: English, Japanese, French, German and Spanish 6. Synchronization (option): Cross-talk between flowmeters located closely or acoustic interference between flowmeters installed on the same pipe line can be removed by using this synchronization function of transmission timing of ultrasonic waves. SPECIFICTIONS Operational specifications System configuration: The system is composed of a detector (Model FLS... ) and a flow transmitter (Model FLR... ), realizing single-path system. pplication: Liquid flow without aeration that ultrasonic wave can propagate (purified water, cooling water, corrosive liquids, cooling/heating medium, etc.) Turbidity: deg (mg/l) or less Fluid temperature: - to +deg.c With silicon rubber ( for acoustic couplant ) to +6deg.C With silicon-free grease for acoustic couplant ( ) Flow Transmitter (FLR) (FLS) Type of flow: Well-developed turbulent or laminar flow in a full-filled pipe pplicable flow pipe: Pipe size: 5 to mm (FLSE) or 5 to 5mm(FLSE) for plastic pipes 5 to mm (FLSE) or 5 to 5mm (FLSE) for metal pipes Material: Plastics (PVC, PVDF, PEEK, PP, FRP, etc.) or Metals (Carbon steel, SS, copper, aluminum, etc.) Liner: Tar epoxy, mortar, rubber, and others Fundamental straight pipe: D for upstream and 5D for downstream (D: pipe diameter) Refer to Conditions on straight pipe for details. Velocity: to ±.... ±m/s Power supply: to V C ±%, 5/6Hz or to 4V C ±%, 5/6Hz or to V DC Signal cable: RF co-axial cable up to m with water-proof BNC at one end and thermal stability of deg.c Environment: Non-explosive environment without direct sunlight, corrosive gas and heat radiation mbient temperature: - to +5deg.C for flow transmitter - to +6deg.C for detector mbient humidity: 9%RH or less Grounding: Class D (less than ohm) EDS6-d Date Dec.,

2 FLR, FLS, FL Synchronization (option): Cross-talk when located closely or acoustic interference when installed on the same pipe line removable by simultaneous transmission of ultrasonic waves Number of connectable units: up to Cable length: up to 5m Master/Slave selectable rrester (option): rrester unit for outputs available (while arrester for power supply incorporated as standard) Performance specifications ccuracy: Pipe size (inside dia.) m/s or more Less than m/s 5 to less than 5mm ±% of rate ±.6m/s 5 to 5mm ±% of rate ±.4m/s Response time: System cycle:.s Dead time: less than.s, Time constant:.s Power consumption: 5V or less for C power supply 5W or less for DC power supply Permissible air volume rate: Up to.% at m/s (inversely proportional to velocity) Short-term thermal stability: 4deg.C, min Functional specifications nalog output:4 to m DC ( point) Max. load resistance : 6 ohm Digital output:+ total, - total, alarm, acting range, flow switch or total switch arbitrarily available Transistor open collector: point (DO) Capacity: V DC,. Normal off/on selectable Total pulse: pulse/day to pps (Pulse width: 5,, 5, or ms) Mechanical relay contact: point (DO), with socket (exchangeable) Normal close/open selectable Capacity: V C /V DC, (resistive load) Mechanical expected life: More than x 7 operations Total pulse: pulse/day to pps (Pulse width: 5, or ms) Communication interface (option): RS-C equivalent / RS-485 Number of connectable units: one (RS-C)/ up to (RS-485) Baud rate: 4/48/96/9 bps selectable Parity: /Odd/Even selectable Stop bit: or bits selectable Cable length: up to 5m (RS-C)/up to km (RS-485) Data: Velocity, flow rate, +total, -total, status, etc. Display device: -color LED (Normal: green, Extraordinary: red) LCD with lines of 6 characters and back light Display language: English, Japanese, French, German or Spanish selectable Velocity/Flow rate display: Display of velocity and/or flow rate with flow direction Number: 9 digits (decimal point be counted as digit) Unit: Metric/Inch system selectable Metric system Inch system Velocity m/s ft/s Flow rate L/s, L/min, L/h, kl/h, ML/d, m /s, m /min, m /h, Mm /d, BBL/s, BBL/min, BBL/h, MBBL/d Note: The gal means USgal. gal/s, gal/min, gal/h, kgal/h, Mgal/d, ft /s, ft /min, ft /h, Mft /d, BBL/s, BBL/min,BBL/h, MBBL/d Total display: Display of forward or reverse total Number: 7digits (decimal point be counted as digit) Unit: Metric/Inch system selectable Total Metric system ml, L, m, km, Mm, mbbl, BBL, kbbl Inch system gal, kgal, ft, kft, Mft, mbbl, BBL, kbbl, CRE-in, CRE-ft Configuration:Fully configurable from the 4-key pad (ESC,,, ENT) on the surface of flow transmitter s housing case by menu-driven software Zero adjustment: Set zero/clear available Damping: to s (every s) configurable for analog output and display Low flow cut off : to 5m/s configurable larm: Hardware fault/process fault applicable to digital output Burnout: nalog output : Hold/Over-scale/Under-scale/ Zero selectable Total: Hold/Count selectable Working timer : to s (every s) configurable Bi-directional range: Forward and reverse ranges configurable independently Hysteresis: to % of acting range configurable cting range applicable to digital output uto- ranges: Forward ranges configurable independently Hysteresis: to % of acting range configurable cting range applicable to digital output Flow switch: Lower and upper switching points configurable independently cting point applicable to digital output Total switch: +total switching point configurable cting point applicable to digital output

3 Physical specifications Enclosure protection: IP65 for both flow transmitter and detector (When water-proof BNC is applied) Mounting: Flow transmitter: Wall/B pipe mount : Clamped on pipe surface coustic coupler: Silicon rubber or silicon-free grease Material: Flow transmitter: Plastic BS : Plastic PBT for sensor housing, 4SS for guide frame Sensor cable: DV with outside diameter 5mm Dimensions: Flow transmitter: H4 x W9 x D68mm : H8 x W4 x D5mm for FLSS H8 x W6 x D5mm for FLSS Mass: Flow transmitter:.8kg :.kg (FLSS) /.4kg (FLSS) Conditions on straight pipe ( D : Inside diameter of pipe) Classification Upstream side Downstream side L 5D 9 bend D or more L D Tee D or more L 5D L D D or more.5d or more L D L 5D Diffuser D.5D L D L 5D Reducer L D L D Various Valve Pump In case that flow control valve exists on upstream side. Check valve P Stop valve In case that flow control valve exists on downstream side. L 5D (Note) The source : JEMIS-

4 FLR, FLS, FL MESURING PRINCIPLE Velocity V Sensor Upstream-side sensor CONFIGURTION θ () Single-path system (V method) t t Downstream-side sensor Flow transmitter nalog output Contact output The transit-time technique uses a pair of sensors with each sensor sending and receiving ultrasonic signals obliquely through the fluid. When the fluid is flowing, transit-time in the forward direction is shorter than one in the reverse direction. s the difference between these transit-time is proportional to the velocity, the flow rate and direction can be measured properly by detecting such time difference. D CODE SMBOLS <Flow Transmitter> F LRE Description E 4 B C B Type (4th digit) Standard for exports Power Supply (5th digit) to Vac, 5/6Hz to 4Vac, 5/6Hz to Vdc Communication & Synchronization (6th digit) RS-C RS-485 & Synchronization Synchronization rrester (7th digit) With arresters for outputs Modification No. (8th digit) Mark Case structure (9th digit) IP65 Mounting bracket (th digit) For B pipe mount For wall mount Option (th digit) Cable Flow transmitter 4 to m DC Contact signals up to points (Note) This type has not so tough endurance against aeration as Fuji's general use ultrasonic flowmeters TIME DELT-S/F (Model: FLV/FLH) and PORTFLOW-X (Model: FLC). For applications containing air bubbles, those general use flowmeters are recommendable to be used. <> () When using synchronization Cable Cable Flow transmitter (Master) Flow transmitter (Slave) 4 to m DC Contact signals Synchronization 4 to m DC Contact signals F LSE E B Type (4th digit) Standard Description Kind of detector (5th to 6th digit) Small size detector (for 5 to mm) Middle size detector (for 5 to 5mm) coustic coupler (7th digit) Silicon rubber (Fluid temperature: - to + deg.c) Silicon-free grease (Fluid temperature: to +6 deg.c) Modification No. (8th digit) Mark Mounting method (9th digit) Standard (V-mount) Option (th digit) <Signal cable> F L Description 5 5 Kind of cable (4th digit) Heat resisting cable with water-proof BNC Cable length (5th to 7th digit) 5m (one pair) m (one pair) 5m (one pair) m (one pair) m (one pair) Modification No. (8th digit) Mark 4

5 OUTLINE DIGRM (Unit:mm) <Flow transmitter (type: FLR)> PIPE MOUNT (OPTION) Mtg. plate 7 Mtg. holes 9dia. U bolt (M8) Mtg.pipe JIS B 4 7 (97) M-Flow 4.5 Cable gland For sensor cable (PG9) For power supply & output cable (PG.5) External grounding terminal CONNECTION DIGRM RS-485 & Synchronization C power supply SNC SHILD TXDR TXDR L N I out DO Upstream Upstream DO Synchronization RS-485 to V C or to 4V C 5/6Hz GND HF GND HF RS-C NC GND RXD TXD DC power supply I out DO DO Downstream Downstream to V DC (Note) DO : Transister open collector DO : Mechanical relay contact 5

6 FLR, FLS, FL < (type: FLS)> Saddle BNC connector Sensor Spacing (dustable every mm) Lock clip L Frame 4 8 H (5) Type FLSE FLSE Pipe size (mm) 5 to 5 to 5 L 4 6 H Spacing to to 4 Mass. approx. (kg)..4 SCOPE OF DELIVER Flow transmitter FLR: Flow transmitter Instruction manual FLS: Sensor unit Mounting belt Silicon rubber/ Silicon-free grease (option) Signal cable FL : Orignal cable ( wires) The product conforms to the requirements of the Electromagnetic compatibility Directive 89/6/EEC as detailed within the technical construction file number TN5. The applicable standards used to demonstrate compliance are : EN 66 : 998 Electrical equipment for measurement, control and laboratory use EMC requirements Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Head office -, Osaki -chome, Shinagawa-ku, Tokyo, 4- Japan Sales Div. International Sales Dept. No., Fuji-machi, Hino-city, Tokyo, 9-85 Japan Phone: , 6 Fax: Information in this catalog is subject to change without notice. Printed in Japan

ULTRASONIC FLOWMETER < >

ULTRASONIC FLOWMETER < > SERIES ULTRSONIC FLOWMETER < > DT SHEET FS, FLS/FLW/FLD This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electronics and digital

More information

Detector (FLS) Flow transmitter (FSV)

Detector (FLS) Flow transmitter (FSV) TIME DELT-C (FLS) transmitter (FSV) High accuracy measurement : 1.0% of rate Superior anti-bubble performance : Our dvanced M method is adopted. Maintenance free operation : Non-invasive setup with no

More information

HYBRID ULTRASONIC FLOWMETER <Duosonics> (Pulse Doppler method + Transit Time method)

HYBRID ULTRASONIC FLOWMETER <Duosonics> (Pulse Doppler method + Transit Time method) HBRID UTRASONIC FOWMETER (Pulse Doppler method + Transit Time method) DATA SHEET FSH, FSW, F This meter is the world s first non-intrusive type ultrasonic flowmeter utilizing Pulse Doppler

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Instruction Manual ULTRASONIC FLOWMETER. TYPE: FSV (Flow transmitter) FLS, FLW, FLD (Detector) FLY (Signal cable) INF-TN1FSVG-E

Instruction Manual ULTRASONIC FLOWMETER. TYPE: FSV (Flow transmitter) FLS, FLW, FLD (Detector) FLY (Signal cable) INF-TN1FSVG-E Instruction Manual ULTRASONIC FLOWMETER TYPE: FSV (Flow transmitter) FLS, FLW, FLD (Detector) FLY (Signal cable) INF-TN1FSVG-E Introduction We thank you very much for purchasing Fuji Electric s ultrasonic

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

ULTRASONIC FLOW METER FT101

ULTRASONIC FLOW METER FT101 Introduction F t101 is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that

More information

Technical specification FLUXUS F401 H2O

Technical specification FLUXUS F401 H2O Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter Portable flowmeter with two measurement channels, optional process outputs and Heat Quantity Measurement capability For commonly used pipe materials and diameters from 10 mm to over 3.0 m Intuitive menu,

More information

ULTRASONIC FLOWMETER M-Flow PW Flow transmitter

ULTRASONIC FLOWMETER M-Flow PW Flow transmitter Instruction Manual ULTRASONIC FLOWMETER M-Flow PW Flow transmitter TYPE: FLR-3 PREFACE We thank you very much for purchasing Fuji s ultrasonic flowmeter. The instruction manual concerns the installation,

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

Fuji Ultrasonic Flowmeter Series

Fuji Ultrasonic Flowmeter Series Fuji Ultrasonic Flowmeter Series 21A1-E-0008 Features of ultrasonic flowmeter in flow rate measurement 1. Total cost reduction allowed by elimination of piping installation 2. Can be installed even while

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

PRODUCT DATA SHEET. Stationary. Ultrasonic Flowmeter UFL-30

PRODUCT DATA SHEET. Stationary. Ultrasonic Flowmeter UFL-30 PRODUCT DATA SHEET Stationary Ultrasonic Flowmeter UFL-3 1. Outline 1) Transit times of ultrasonic pulses transmitted in a liquid vary with the flow velocity of the liquid and ultrasonic flowmeters utilize

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

LEVEL TRANSMITTER <SANITARY TYPE>

LEVEL TRANSMITTER <SANITARY TYPE> LEVEL TRNSMITTER DT SHEET FKE...4 The FCX 2 level transmitter accurately measures liquid level and transmits a proportional 4 to 20m signal. The transmitter utilizes a unique micromachined

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range TM B r e a k t h r o u g h F l o wmeter Technology Ultrasonic Flowmeter Range IDEAL FOR: Drink dispensing Laboratory tests Cooling equipment Active flow alarms Semiconductor plant OEM applications Pilot

More information

+GF+ SIGNET Temperature Transmitter Instructions

+GF+ SIGNET Temperature Transmitter Instructions GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)

PRESSURE TRANSMITTER (DIRECT MOUNT TYPE) PRESSURE TRNSMITTER (DIRECT MOUNT TYPE) DT SHEET FKP...5 The FCX III pressure transmitter accurately measures gauge pressure and transmits proportional 4 to 20m signal. The transmitter utilizes the unique

More information

Insertion Flow sensor for continuous flow measurement

Insertion Flow sensor for continuous flow measurement Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface

More information

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications Description The Vortex PhD vortex shedding flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process fluid line (the bluff body). A

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Overview SITS FUH1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for applications carrying crude oil, refined petroleum or liquefied gas. SITS FUH1010 has three application areas: Interface detectors,

More information

Mass and Volume Flow Transmitter

Mass and Volume Flow Transmitter IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,

More information

M-2111 Series Ultrasonic Flow Meter

M-2111 Series Ultrasonic Flow Meter M-2111 Series Ultrasonic Flow Meter High Accuracy/Non-contact Flow Sensing in PFA Key Features Accuracy ± 1% of reading Repeatability ± 0.5% of reading All wetted parts made of New PFA (AP- 211SH) Contamination

More information

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016

Advancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016 Advancements in Clamp-on Ultrasonic Flow Measurements 2016 Biosolids Workshop December 1 st 2016 Market Leader in Clamp-On Ultrasonic Flowmeters with >50,000 instruments sold Background Information Extraordinary

More information

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

SITRANS F US Clamp-on

SITRANS F US Clamp-on Siemens G 2013 Overview Standard volume Exceptional repeatability is maintained, independent of changes in temperature, density or viscosity Batch interface and product quality diagnostics provided Density

More information

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS Rev04009 USER MANUAL DEI MODEL USFT-CS USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER The Model USFT-CS is an ultrasonic transit time flow meter designed to accurately and reliably report the flow

More information

PRODUCT DATA SHEET. Stationary. Ultrasonic Flowmeter UFL-30

PRODUCT DATA SHEET. Stationary. Ultrasonic Flowmeter UFL-30 PRODUCT DATA SHEET Stationary Ultrasonic Flowmeter UFL-3 1. Outline 1) Transit times of ultrasonic pulses transmitted in a liquid vary with the flow velocity of the liquid and ultrasonic flowmeters utilize

More information

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm) KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%

More information

LST100 Ultrasonic level transmitter for upstream oil and gas

LST100 Ultrasonic level transmitter for upstream oil and gas Data sheet DS/LST100-EN LST100 Ultrasonic level transmitter for upstream oil and gas Accurately track and measure the most expensive consumable on your site chemicals. Measurement made easy Features Keep

More information

Applications Features

Applications Features GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system

More information

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS

More information

FAST SAMPLING CONVERTER

FAST SAMPLING CONVERTER FAST SAMPLING CONVERTER ML4-F1 HIGH SAMPLING RATE CONVERTER (UP TO 400 SAMPLES/SECOND) Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Technical Specification FLUXUS ADM 8127B

Technical Specification FLUXUS ADM 8127B FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

SERIES < > ULTRASONIC FLOWMETER

SERIES < > ULTRASONIC FLOWMETER DT SHEET SERIES < > ULTRSONI FLOWMETER FSV-2, FSS, FL This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electronics

More information

S L n u. M e. E n te r. Transmitter: Flow range: 0 ~ ±40ft/s (0 ~ ±12m/s) Accuracy: ±1.0% Repeatability: 0.3% Outputs: OCT, KHz

S L n u. M e. E n te r. Transmitter: Flow range: 0 ~ ±40ft/s (0 ~ ±12m/s) Accuracy: ±1.0% Repeatability: 0.3% Outputs: OCT, KHz S L 1 16 8 7 8 9 M e n u 4 5 6 1 2 3 E n te r 0 Transmitter: Flow range: 0 ~ ±40ft/s (0 ~ ±12m/s) Accuracy: ±1.0% Repeatability: 0.3% Outputs: OCT, 0-9999 KHz Sl 1168 Ultrasonic Flowmeter Brochure Series1168

More information

PanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits

PanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits GE Measurement & Control PanaFlow HT Panametrics Ultrasonic SIL Flow Meter for Liquids pplications PanaFlow HT is a SIL-rated flow meter used for flow measurement of liquids in either nominal or extremely

More information

General Specifications

General Specifications General Specifications US300FM Ultrasonic Flowmeter GS 01G05B03-01E GENERAL The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing

More information

PRESSURE TRANSMITTER <SANITARY TYPE> FKB...4

PRESSURE TRANSMITTER <SANITARY TYPE> FKB...4 DT HEET REMOTE EL TYPE PREURE TRNMITTER FK...4 The FCX 2 pressure transmitter accurately measures gauge pressure and transmits a proportional 4 to 20m signal. The transmitter utilizes a unique

More information

Electromagnetic Flowmeter Hygienic/Sanitary

Electromagnetic Flowmeter Hygienic/Sanitary MagMaster Electromagnetic Flowmeter Hygienic/Sanitary Specification DataFile Unrivalled, fully traceable flow performance, ±0.2% accuracy. Operable flow range: 000 : ensures precise revenue measurement;

More information

Process Protection Acoustic sensors for pump monitoring

Process Protection Acoustic sensors for pump monitoring coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement

More information

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance.

Level Transmitter / Controller / Indicator. 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance. Level Transmitter / Controller / Indicator 3-in-1 package that is simple to install and use. With expanded ranges and improved chemical resistance. 2.1 NEW Class 1, Division 1 Hazardous Areas Approved

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

1/16 DIN (48 48 mm) temperature controller PXR

1/16 DIN (48 48 mm) temperature controller PXR / DIN (8 8 mm) temperature controller PXR Features Large LED display and front waterproof structure Easy-to-see, large LED display (. times larger than current models) Easy-to-wire screw terminal design

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016 J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter Field Intelligent Device Series Electromagnetic Flowmeter Converter LF620,LF622 Introduction Combined with a multi-functional converter LF620 (combined type) or LF622 (separate type) equipped with its

More information

User s Manual CM2-MGR nd edition

User s Manual CM2-MGR nd edition MagneW 3000 Electromagnetic Flowmeter Hyper-Fill Model: MGR13C (Converter) MGR11U (Detector) User s Manual CM2-MGR100-2001 2nd edition Copyright, Notices and Trademarks 2005-2012 Azbil Corporation All

More information

Technical Specification FLUXUS ADM 8x27

Technical Specification FLUXUS ADM 8x27 Ultrasonic Flow Measurement of Liquids in Explosive Atmosphere Features Transducers non-invasive (no contact with the medium, no need for expensive materials) wearfree no pressure drop (no operational

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG

Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG Inexpensive PD for Boiler Feed Water and Oil FLOWPET-EG GENERAL SPECIFICATION GS.No.GBB323E-5 GENERAL FLOWPET-EG is an OVAL flowmeter primarily intended for use in boiler feed water and fuel oil metering

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter.   TEMPERATURE. Technology Solutions Technology Solutions TEK-TEMP 2100A Explosion-Proof Temperature Transmitter TEMPERATURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction Tek-Trol s Explosion-Proof

More information

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER DESCRIPTION The UltraFlo UFDD Clamp-On Ultrasonic Flow Meter is the ideal flow meter with accurate, easy-to-use, easy-to-install digital doppler technology.

More information

Advanced instrumentation solutions crafted with highest precision

Advanced instrumentation solutions crafted with highest precision www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters

More information

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009 VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

Product Discontinuation Notices

Product Discontinuation Notices PRODUCT NEWS Product Discontinuation Notices August 1, 2011 Ultrasonic Sensors No. 2011264E Discontinuation Notice of Ultrasonic Sensor E4A special specification model, E4B special specification model,

More information

B850 Boiler House Energy Monitor

B850 Boiler House Energy Monitor Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

MICRO-CONTROLLER X (48mm 48mm)

MICRO-CONTROLLER X (48mm 48mm) PX series Digital temperature Controller DT SHEET Socket Type With front dimensions of 8 8mm, this socket type temperature controller enables OnOff control, PID control or 8step ramp/soak function, using

More information

General Specifications

General Specifications General Specifications US300FM Ultrasonic Flowmeter GS 01G05B03-01E GENERAL The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flowmeter The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

WATERFLUX 3000 Quick Start

WATERFLUX 3000 Quick Start WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ). ISO-14001 ISO-9001 SPECIFICATION SHEET CP SERIES 2-WIRE TYPE DO TRANSMITTER Models: DCP-20T FEATURES Rigid aluminium enclosure with free angle mounting. Simple operation offers free range setting, auto-calibration,

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information

ThermoPLUS Smart Temperature Transmitter

ThermoPLUS Smart Temperature Transmitter No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature

More information

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK Efcon Water Installation & User Manual Electro Magnetic Flowmeter (EMF) Page 1 Table of content Page 1.1 General 3 1.2 Application area 4 1.3 Transportation 4 1.4 Principle of Operation 4 1.5 Product Description

More information

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

Electromagnetic Flowmeter

Electromagnetic Flowmeter Data Sheet Electromagnetic Flowmeter MagMaster Loflo Industry-specific design for the water and waste water industries in diameters from 5mm ( /2 in.) to 6mm (24in.) Wide flow range with.25% accuracy Extended

More information

UTM10 Series Ultrasonic Transit-time Flowmeters

UTM10 Series Ultrasonic Transit-time Flowmeters Ultrasonic Transit-time meters Description UTM10 ultrasonic flow and energy meters clamp onto the outside of pipes and do not make contact with the internal liquid. The technology has inherent advantages

More information

Introduction. Note. Described in the nameplate put on the main body. Product nationality:

Introduction. Note. Described in the nameplate put on the main body. Product nationality: Introduction We thank you very much for purchasing Fuji Electric s ultrasonic flow meter. The instruction manual concerns the installation, operation, checkup and maintenance of the Flow transmitter (FSV)

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

IFC 010 Signal Converter

IFC 010 Signal Converter KROHNE 04/2003 7.02347.22.00 GR Signal Converter for electromagnetic flowmeters Easy to install Low-cost signal converter, measuring error < 0.5% of the measured value Easy user-friendly operation Self-monitoring

More information

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed

More information

PROSOL PCS Ultrasonic Flowmeter Installation and User Guide V

PROSOL PCS Ultrasonic Flowmeter Installation and User Guide V Index PROSOL PCS Ultrasonic Flowmeter Installation and User Guide V 18.4.1 1.0 Component Identification 1.1 Meter Specifications 2.0 Preparation for Installation 3.0 Installation / Set up 3.1 Menu Navigation

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,

More information