Electromagnetic Flowmeter Hygienic/Sanitary

Size: px
Start display at page:

Download "Electromagnetic Flowmeter Hygienic/Sanitary"

Transcription

1 MagMaster Electromagnetic Flowmeter Hygienic/Sanitary Specification DataFile Unrivalled, fully traceable flow performance, ±0.2% accuracy. Operable flow range: 000 : ensures precise revenue measurement; superior process control Approved hygienic/sanitary design with choice of connections allows clean-in-place and total flexibility of installation Designed and manufactured to internationally accepted standards ISO 900, A, FDA system ensures reliable, maintenance-free operation Fully-featured transmitter with comprehensive display and output options, including HART allows easy integration into other systems and clear operator interface Corrosion free polypropylene transmitter enclosure IP65/NEMAX suitable for all brewing, food, pharmaceutical and dairy environments MagMaster bringing unsurpassed flowmetering performance to the brewery, dairy, pharmaceutical and food processing industries.

2 Introduction Setting the MagMaster the high performance flowmeter from ABB Instrumentation is now available in a hygienic/sanitary version for food processing and pharmaceutical applications. MagMaster is designed for use in dairies, breweries, pharmaceutical and liquid food processing markets and it takes hygienic/sanitary flowmetering to new levels of capability and performance. The new range brings to these industries a proven level of performance which is unsurpassed in electromagnetic flow measurement. Unrivalled Performance MagMaster provides reliable measurement from high capacity down to virtually zero flow rates. Its potential operating flow range of 000: enables previously unregistered minimal flows to be metered with an accuracy of ±0.2% of reading or ±0.00 m s (0.00 ft s ) (whichever is the greater). Users can now achieve more precise revenue measurement and superior process control. Hygienic/sanitary Design MagMaster s wide temperature, hygienic/sanitary design eliminates germ traps and is suitable for CIP (Clean-in-Place) using chemical cleansers, hot water and steam rinses. All external crevices have been eliminated from the sensor to ensure easy and effective hose-down. Flowmeters, and Couplings Fully Approved to International s MagMaster conforms to a wide range of national and international standards to meet hygienic/sanitary requirements for measurement and food processing legislation. Approvals include: A licensed, FDA system, FM and CSA general purpose. The meter s PTFE lining is approved and its housing is designed to be compatible with a hygienic/sanitary environment. Flexible Installation The new range is available in sizes from 20 mm (0.75 in) to 80 mm ( in) the latter size also being available with 00 mm ( in) mating couplings. The standard installation connections are tri-clamp, ISO 2852 or DIN 85 male screw connectors. Tough in Service The new range of meters is extremely robust and can withstand the stresses of being installed in a tanker and also accommodates the widely differing operating conditions encountered in liquid food and pharmaceutical applications. Fully Featured s There is a choice between the Industry Reference MagMaster transmitter and the hygienic/sanitary version. The hygienic/sanitary version minimizes germ traps, thus facilitating cleaning. The local communication connector is omitted and a hygienic/sanitary terminal cover is fitted to the front of the unit. The transmitter is tamper-proof thus ensuring integrity of measurement. Easy-to-Use Simple to Interface Both transmitters feature the option of a display which provides three internal totalizers covering forward, reverse and nett flow in a wide range of volumetric units. Flowrate display in forward and reverse directions in volumetric flowrate units is also provided. The display option, together with the wide choice of outputs analog, pulse, serial data, Hart, etc. ensures compatibility with both the user s display and control system requirements. Installation of the system is simplified by the universal power supply (available for a.c. or d.c. supplies) which enables the system to be used over very wide ranges of voltage with no manual voltage selection being required. Maintaining the MagMaster is designed and manufactured in accordance with international quality procedures (ISO 900) and all flowmeters are calibrated on nationally traceable calibration rigs to provide the end user with complete assurance of both quality and performance of the meter. 2

3 General Specification Sizes Mounting mm Size in m h Flow Range Minimum Maximum US g min m h US g min 5 maximum * 20 * Sensor Electrodes *DIN only. For accuracy see graph below. 00 mm/ in couplings with 80 mm/ in sensor Connections /Sensor Separation < 00 m (28 ft) Accuracy (under reference conditions) 5.0 Tri-clamp ISO 2852 DIN Accuracy % < ± mm s (0.00 ft s ) for velocities 0.5 m s (.5 ft s ) Straight pipe requirements > 5 x pipe dia. * > 2 x pipe dia. *.0 minimum minimum (.5) 5 (50) Analog output Temperature effect Velocity m s (ft s ) Additional < ±0.008 ma < ±0.08% of reading/0 C Analog output Additional <±0.08% of reading/0 C Sensor < ±0.02% of rate/0 C Repeatability and Reproducibility < ±0.05% or < ±0.25 mm s, whichever is the greater Power supply variation Negligible Power consumption Flow Direction * Note. To comply with FDA system requirements > 0 x pipe diameters upstream and downstream < 20 VA Conductivity 5 µs cm

4 Sensor Specification Sizes Size mm (in) D imensions mm (in) Approx. Weight A B C kg 20 (0.75) 7 (6.85) (.22) () 7 (6.85) (.22) (.5) 20 (8.27) 28 (5.0) 28 (.8) (2) 20 (8.27) 28 (5.0) 28 (.8) (2.5) 280 (.02) 22 2 (2.28) () 280 (.02) 22 2 (2.28) () * 280 (.02) (5.) * 00 mm/ in couplings with 80 mm/ in sensor lb Materials Item Material Metering tube & fittings Stainless steel 6 Lining Gaskets (Transition joints) Electrodes PTFE (complies with FDA system and A regulations) N itrile rubber:05 C (22 F) E PDM: 5 C (275 F) Stainless steel 6 Hastelloy C Sensor & terminal box housings White nylon-coated aluminium B 0 (.09) 55 (2.7) C 88 (.6) Pressure Limitations A = 50%A Size mm (in.) Pressure bar (lb/in2) Minimum* Maximum Transition joint Tri clamp or DIN (Male fitting Gaskets not supplied) 20 to 65 (0.75 to 2.5) 80 () 00 () 0.25 (.75) 7 (250) 0.25 (.75) 7 (250) *Absolute Environmental Protection (when installed) IP65/NEMA X Temperature Ranges Operating Ambient Approvals/Licenses A FDA system FM/CSA applied for EPDM gaskets 5 C (275 F) Nitrile rubber gaskets 05 C (22 F) 70 C (58 F) 0 C ( 22 F) 0 C ( 22 F)

5 Specification Display (optional) Forward flow total Reverse flow total Net flow total Alarms Flow Velocity in m s or ft s Flow Rate % of Range Flow rate >567 Ltr 2.28Ltr/s Electrical connections Common ma Forward Reverse < 2 ma, 6 V 20 mm plastic glands, or accepts /2 in NPT connectors. (Face seals required) < 800 Hz, < 5 V open collector square wave, or fixed pulse width <2.5 s, > 250 ma Choice of 9 alarms < 5 V, > 250 ma open collector Power Supply Voltage Type Temperature Ranges Voltage Range (V) Absolute rating Frequency (Hz) VA a.c. 85 to to 0 <2 0 d.c. to 0 <2 0 Totalizer reset Dual range selection Output hold Zero output Industry Reference RS22 (local only) Dual ma (Optional) RS22/2 (Optional) Contact closure or logic input 9-pin D-connector, configuration Dual analog (optional) Non-active output is ma or 0 ma Operating Storage HART (Optional) 60 C (0 F) 75 C (67 F) Hygienic/Sanitary 0 C ( F) 5 C (5 F) Dual ma (Optional) RS22/2 Dual analog (optional) Non-active output is ma or 0 ma HART (Optional) Environmental protection IP65/NEMA X Approvals Electrical safety BS7 Class (IEC 8) FM and CSA applied for EMC Specification Conforms to EMC Directive 89/6/EEC Outputs/Inputs Galvanic separation to 50 V d.c. between analog, pulse/alarm and earth/ground Enclosure Glass loaded polypropylene, polycarbonate window, polycarbonate terminal cover (Hygienic/sanitary version) 5

6 Sensor Ordering Information Sensor MF/ E XXX X A X X XX X Calibrated Bore 20mm (0.75 in). DIN ONLY. 25mm ( in) 0mm (.5 in) 50mm (2 in) 65mm (2.5 in) 80mm ( in) 00mm ( in) End Connections Hygienic, ISO 2852 (Tri-clamp/Clover) Hygienic, DIN 85 Electrodes 6 stainless steel Hastelloy C Gasket Material Nitrile rubber EPDM Cable Length No cable 0m ( ft) 20m (66 ft) 0m (98 ft) 0m ( ft) 50m (6 ft) User specified length in metres Glanding 20 mm plastic conduit entry 0.5 in NPT G H 2 A B X0 Overall Dimensions Dimensions in mm (in) 6.5 (6.6) 6.5 (0.25) ( POSN) 2 (8.) 22 (9.) 29 (.) = 69 = = (2.72) =.5mm =.6in Unit Depth = 70 (2.75) 6

7 Ordering Information X E X X X X X X X Glanding 20 mm plastic gland 0.5 in NPT connection Type Industry Reference MagMaster Hygienic MagMaster Power Supply 95 V to 2 0Va.c. 2 V to 5 Vd.c. Display Blind 2-line high integrity display -line display with keypad Output Options How to Order Sensor Model MFE 00GAA0 0mm bore Hygienic/sanitary ISO2852 (Tri-clamp/Clover) 6 Stainless steel Nitrile rubber gasket 0 m cable length 0.5 in NPT connection Model 0.5 in NPT connection MagMaster Hygienic/Sanitary 95 V to 20 Va.c.supply No display English language R S Tx Type R 0 Dual current R HART communications * R 2 RS2/22 serial communications R RS2/22 serial communications + dual current R 5 S 6 Dual current S 7 HART communication S 8 Build FM, CSA General Approval Language English French German Spanish Italian Dutch Labels Factory allocated * Only available on UK versions ES06 Features U ser re-programmable Local hand-held configurator programming e.g. Psion, etc. F ully configurable A choice of engineering parameters in engineering units, e.g. flowrate, flow units, all outputs, etc. E mpty pipe sensing Ensures units read zero on empty pipe. I nterchangeability can be changed without affecting performance. S elf-diagnostics Ensures transmitter and sensor integrity. T est mode Powerful commissioning aid. Exercises all outputs and displays, even without a connected sensor. Multi-lingual Displays, programming and prompts available in English, French, German, Spanish and Italian other languages on application. 7

8 Connection Information Sensor Connections Connections Supply Fuse N ( ) L (+) BLK PULSE/ ALARMS INPUT RS 22/2 ALARM FOUTA / FWD ALARM2 FOUTB / REV PLS0V PLS0V EXTI/P+ EXTI/P TX SIG RX SIG TX+SIG RX+SIG 0VC IC2 /DUAL I IC+ CD IC CD2 BLK2 220R 220R 5V HART CD CD2 SIGGND DS SIG SIG2 DS2 BLK SIGGND DS SIG SIG2 DS2 Optional * ESCRN *ABB cable Note. Remove any exposed black conductive layer from the inner insulation of both coaxial cables. The Company's policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. ABB 2000 Printed in UK (.00) SS/MAG/HS Issue 6 ABB Automation Ltd Oldends Lane, Stonehouse Gloucestershire, GL0 TA UK Tel: + (0) Fax: + (0) ABB Automation Inc 25 E. County Line Road Warminster, PA 897 USA Tel: Fax: ABB has Sales & Customer Support expertise in over 00 countries worldwide 8

Electromagnetic Flowmeter

Electromagnetic Flowmeter Data Sheet Electromagnetic Flowmeter MagMaster Loflo Industry-specific design for the water and waste water industries in diameters from 5mm ( /2 in.) to 6mm (24in.) Wide flow range with.25% accuracy Extended

More information

ABB Instrumentation. Flowmeter. Specification DataFile

ABB Instrumentation. Flowmeter. Specification DataFile MagMaster Electromagnetic Flowmeter Specification DataFile Process MagMaster for unrivalled flow performance ±0.2% accuracy. Operable flow range of 0:1. Slurry MagMaster for all slurries, pulps and pastes.

More information

Electro-Magnetic Flowmeters COPA-XE

Electro-Magnetic Flowmeters COPA-XE Data Sheet Electro-Magnetic Flowmeters COPA-XE 10DX4311 Flowmeter system utilizes a smart microprocessor converter System accuracy of ± 0.5% of rate Field configurable via integral pushbuttons, eliminates

More information

Conductivity Analyzer

Conductivity Analyzer Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures

More information

Ambient Conditions. Operating Conditions. Pressure

Ambient Conditions. Operating Conditions. Pressure Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version

More information

CONTENTS Page 1 INTRODUCTION SUPPLEMENTARY INSTRUCTIONS TO BOOK 3 ELECTRICAL INSTALLATION Section Page 1 INTRODUCTION The cable supplied with your Mag

CONTENTS Page 1 INTRODUCTION SUPPLEMENTARY INSTRUCTIONS TO BOOK 3 ELECTRICAL INSTALLATION Section Page 1 INTRODUCTION The cable supplied with your Mag CONTENTS Page 1 INTRODUCTION SUPPLEMENTARY INSTRUCTIONS TO BOOK 3 ELECTRICAL INSTALLATION Section Page 1 INTRODUCTION The cable supplied with your MagMasterflowmeter may not be as described in Book 1 or

More information

Multi-electrode Conductivity Analyzers

Multi-electrode Conductivity Analyzers Data Sheet Multi-electrode Conductivity Analyzers Utilizes patented, six-electrode measurement techniques to give accurate results at up to 90% cell fouling enhanced performance and minimized maintenance

More information

Specification DataFile

Specification DataFile DATUM U & U Ultrasonic Level System Specification DataFile 6-digit backlit l.c.d. and bargraph clear display of measured level Echo Processing using 'DATEM' software true level measurement, overcoming

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter Data Sheet D-FMP-10D1475W-Y_4 Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter 10D1475W/Y Flowmeter Systems utilizes a smart microprocessor converter. System accuracy of ±0.5% of

More information

MagMaster Electromagnetic Flowmeters. Instruction Manual

MagMaster Electromagnetic Flowmeters. Instruction Manual MagMaster Electromagnetic Flowmeters Instruction Manual RE GISTERED The Company ABB AUTOMATION ABB Automation is an established world force in the design and manufacture of instrumentation for industrial

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/01.12 71195835 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application The compact measuring

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. AquaProbe FEA100 Insertion-type electromagnetic flow sensor with WaterMaster transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. AquaProbe FEA100 Insertion-type electromagnetic flow sensor with WaterMaster transmitter ABB MEASUREMENT & ANALYTICS DATA SHEET AquaProbe FEA100 Insertion-type electromagnetic flow sensor with WaterMaster transmitter Measurement made easy Maximum performance, minimum hassle Suitable for permanent

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter ABB MEASUREMENT & ANALYTICS DATA SHEET Ultrasonic level LST400 Open channel flow transmitter 2 ULTRASONIC LEVEL LST400 / OPEN CHANNEL FLOW TRANSMITTER DS/LST400 EN REV. D Measurement made easy Reduced

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information

Electronic Water Meter

Electronic Water Meter Data Sheet Widest flow range, highest accuracy measures minimal night and peak day flows Tariff function programmable for daily, weekly & seasonal rates Encoder reading remote reading using standard inductive

More information

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm) KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless

More information

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009 VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet 34-VF-03-14 September 2009 Specification Clamp-on technology HONEYWELL S VERSAFLOW stands for continuity and long term reliability. Flow measurement

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical

More information

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080 Overview The transmitter is available in an IP67/NEMA 4X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1-path or -path) FUS80 (-path) FUE80 (-path) The transmitter FUS080 is always

More information

BATCHFLUX 5500 C Technical Datasheet

BATCHFLUX 5500 C Technical Datasheet BATCHFLUX 5500 C Technical Datasheet Electromagnetic flowmeter for volumetric filling machines High-stability ceramic measuring tube, therefore extremely long-term stability Optimum hygienic design Only

More information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

UFM 800 W, C Ultrasonic flowmeter for water and wastewater KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

Compact Orifice Flow Meter

Compact Orifice Flow Meter Data Sheet DS/OM Issue 2 Compact Orifice Flow Meter OriMaster Integrated DP Flow measurement system combines primary element with DP Transmitter in a single flowmeter assembly One-piece flowmeter, pressure

More information

ABB ph/orp analyzer and probe package

ABB ph/orp analyzer and probe package Water Technologies & Solutions fact sheet ABB ph/orp analyzer and probe package Series AX466 dual input analyzer description and use AX466 analyzers incorporate the latest technology to provide highly

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

IFC 010 Signal Converter

IFC 010 Signal Converter KROHNE 04/2003 7.02347.22.00 GR Signal Converter for electromagnetic flowmeters Easy to install Low-cost signal converter, measuring error < 0.5% of the measured value Easy user-friendly operation Self-monitoring

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple

OriMaster FPD500 Compact orifice flowmeter. Orifice-based flow metering made simple Data sheet DS/FPD500 EN Rev. E OriMaster FPD500 Compact orifice flowmeter Orifice-based flow metering made simple Integrated DP flow measurement system, pressure tested as an assembly combines primary

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP) Data Sheet Analyze IT Single and Dual Input Analyzers for ph/redox (ORP) Cost effective select from two input ph/redox (ORP) or combined ph/redox (ORP) and conductivity in one analyzer High functionality

More information

LST100 Ultrasonic level transmitter for upstream oil and gas

LST100 Ultrasonic level transmitter for upstream oil and gas Data sheet DS/LST100-EN LST100 Ultrasonic level transmitter for upstream oil and gas Accurately track and measure the most expensive consumable on your site chemicals. Measurement made easy Features Keep

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter

Model FLSC-C3-XX. DC Powered Microprocessor Controlled Transmitter Model FLSC-C3-XX DC Powered Microprocessor Controlled Transmitter CONTENTS. Introduction----------------------------------------------------------------- 2 2. Specifications ---------------------------------------------------------------

More information

BATCHFLUX and BATCHCONTROL

BATCHFLUX and BATCHCONTROL KROHNE 04/2001 D 31 BATC 02 E GR/PRINTO BATCHFLUX and volumetric batching and dosing with electromagnetic flowmeters A new era in volumetric batching!!! Optimum sanitary design Ceramic measuring tube Only

More information

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring

More information

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview Siemens AG 2010 Flow Measurement Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the TRANSMAG 2 for pulsed alternating field. These are available as

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for Simplified Chinese, English, French, German

More information

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Technology Solutions www.tek-trol.com 796 Tek Drive Crystal Lake, IL 60014 USA Tel: +1 847 857 6076, +1 847 655 7428 Fax: +1 847 655 6147 Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Sarasota CM200 Sarasota HME900 Density Converter Electronics Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases

CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases Measurement & Analytics Measurement made easy CoriolisMaster Measurement made easy Accurate flow measurement of liquids and gases Measurement made easy Highest measurement accuracy, easy installation and

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

WaterMaster Electromagnetic flowmeter. The perfect fit for all water industry applications

WaterMaster Electromagnetic flowmeter. The perfect fit for all water industry applications Data sheet DS/WM EN Rev. H WaterMaster The perfect fit for all water industry applications The most stable transmitter in the world self-calibrating transmitter and ultra-low temperature coefficient for

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16 Technical Information TI 7C//ae Conductivity Measuring Cells for High-Temperature Applications Two-electrode measuring sensors with fixed cable or connector version with integrated temperature sensor Cell

More information

Advanced instrumentation solutions crafted with highest precision

Advanced instrumentation solutions crafted with highest precision www.adeptfluidyne.com Advanced instrumentation solutions crafted with highest precision Working Principle The Transit Time Flowmeter utilises two transducers that function as both ultrasonic transmitters

More information

Applications Features

Applications Features GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system

More information

FLOWMETER. Siemens MAG 5000/6000. Overview

FLOWMETER. Siemens MAG 5000/6000. Overview Overview Design The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP65/NEMA

More information

LST400 Ultrasonic level / open channel flow transmitter

LST400 Ultrasonic level / open channel flow transmitter Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Flowmeter SITRANS FUE80 with CT approval Overview The 2-path flowmeter SITRANS FUE80 comes as battery or mains-powered and is designed to measure water flow in district heating plants, local networks,

More information

ABB Measurement & Analytics. FSM4000 The electromagnetic flowmeter of choice For critical applications in a wide range of industries

ABB Measurement & Analytics. FSM4000 The electromagnetic flowmeter of choice For critical applications in a wide range of industries ABB Measurement & Analytics FSM4000 The electromagnetic flowmeter of choice For critical applications in a wide range of industries 2 FSM4000 The electromagnetic flowmeter of choice Electromagnetic flow

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters ABB MEASUREMENT & ANALYTICS DATA SHEET TB8 -wire conductivity transmitters TB 8 -W I R E CON DUCT I VI T Y TR ANSMIT TE RS DS/ TB8 -E N RE V. H Measurement made easy Loop-powered transmitters that reduce

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications OPTISONIC 3400 Ultrasonic flowmeter for liquids in all industrial applications Measurement of conductive and non-conductive, low and high viscous liquids, from -200 to +250 C / -328 to +482 F medium temperature

More information

FAST SAMPLING CONVERTER

FAST SAMPLING CONVERTER FAST SAMPLING CONVERTER ML4-F1 HIGH SAMPLING RATE CONVERTER (UP TO 400 SAMPLES/SECOND) Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3

More information

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Process Automation. Sensors and Systems:   Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Process Automation Accurate Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors Flexible Sensors and Systems: www.fafnir.com Reliable FAFNIR Sensors and Systems Reliable,

More information

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Flow Ranges from 0.18-7.8 GPH through 9-180 GPM For Use with a Wide Variety of Conductive Liquids,

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive flow Meter fmi 1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and

More information

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering Change from one to two columns Data Sheet 10/10-3.61-EN Rev. D SensyTemp TSB (B R) Resistance thermometer for building automation, machine construction and environmental engineering Measurement made easy

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis

More information

EN-2018 MAGNETIC FLOW METERS

EN-2018 MAGNETIC FLOW METERS EN-2018 MAGNETIC FLOW METERS www.meatest.com 1 MEASURING PRINCIPLE Having no moving or mechanical parts in the flow profile electromagnetic flow meters cause no pressure drop, are virtually maintenance

More information

SITRANS LR 300: High Performance Radar for Level Measurement

SITRANS LR 300: High Performance Radar for Level Measurement SITRANS LR 300: High Performance Radar for Level Measurement Reliable Measurement In Extreme Conditions SITRANS LR 300 delivers high performance level measurement at an affordable price for the chemical,

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

AT200 External Mount Magnetostrictive Level Transmitter

AT200 External Mount Magnetostrictive Level Transmitter Data sheet DS/AT200-EN Rev. W AT200 External Mount Magnetostrictive Level Transmitter High accuracy liquid level and interface level detection K-TEK Level Products Measurement made easy Features Certified

More information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview Overview Application It provides excellent results on low dielectric media. is available for standard applications and for applications that require explosion proof protection. features robust enclosure,

More information

Proven Measurement for A World of Applications

Proven Measurement for A World of Applications Proven Measurement for A World of Applications Building on Experience. Niagara Meters is a flow meter company representing a complete line of flow meters manufactured by Venture Measurement Co., LLC in

More information

Mass Flowmeter CoriolisMaster FCM2000

Mass Flowmeter CoriolisMaster FCM2000 Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS Rosemount 2051 Product Data Sheet PERFORMANCE SPECIFICATIONS Specifications For zero based spans, reference conditions, silicone oil fill, SST materials, Coplanar flange () or 1 /2 in. - 14 NPT () process

More information

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MaxxFlow HTC Flow Measurement for Dry Bulk Solids EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed

More information