Detector (FLS) Flow transmitter (FSV)
|
|
- Meredith Barber
- 5 years ago
- Views:
Transcription
1 TIME DELT-C (FLS) transmitter (FSV) High accuracy measurement : 1.0% of rate Superior anti-bubble performance : Our dvanced M method is adopted. Maintenance free operation : Non-invasive setup with no moving parts Compact and lightweight : Size and mass reduced by 2/3 (compared with model FLV). Flexible communication functions : RS-232C or RS-485 (MODUS) (option) Wide application range : 13 to 6000mm applicable pipe diameters Quick and easy setup : Simple menu guided setup from the front panel or PC interface dvanced M method: anti-bubble measuring method. ECNO:636a
2 pplicable pipe diameter is 13mm to 6000mm dvanced received signal digital processing results in higher performance flow measurement Normal propagation Propagation interrupted by bubble ubble ubble v Received signal : t Summed 128 or 256 times for a single output Digital data of the received signals : v v Received signal : t Nothing Synchronized summation of received signals t In the case of an analog system, measurement failure will occur. cceptable value of bubble quantity dvanced M method [vol.%] velocity [m/s]
3 oth the mass and volume of the flow transmitter are reduced by 2/3! nalog output 1 point (4 to 20m, insulated) Relay contact output 1 point (insulated, with arrester) Transistor contact 2 points (insulated, with arrester) Communication signal (RS232 or RS485 communication)
4 pplication example Paint (red) transmitter Paint (blue) transmitter Paint (yellow) transmitter Pump Inverter transmitter (type: FSV) pplication: To pump underground water Pump pplication: Water supply to high-rise condominiums and buildings Pump rate regulator (type: PXH) Water supply (type: FLS) Raw water Electromagnetic (type: FM) transmitter (type: FSV) (type: FLS) Ultrapure water is supplied Measurement of the raw water flow rate Semi-conductor manufacturing device Computing unit (type: PD) Heat source Temperature sensor T1: Temperature of the heating medium on the emitting side Temperature sensor T2: Temperature of the heating medium of the receiving side Consumed heat quantity signal (4 to 20mDC) Heat quantity total value pulse signal (DO) Consumed heat quantity K: heat quantity conversion factor (For heating K = 4.123) transmitter (type: FSV) (type: FLS) Q: rate of the heating medium Load
5 CODE SMOL FSV 1 S Description S E 1 4 S C (Language) (4th digit) Standard (Japanese) Standard (English) (Communication) (5th digit) RS232CDI RS485DI (6th digit) Single measuring path (Power supply) (7th digit) 100 to 240VC 50/65Hz 20 to 30VDC (Case structure) (9th digit) Standard (IP66) (Wire connection port) (10th digit) Weatherproof gland provided (Combination with an explosion-proof detector) (11th digit) (Parameter setting) (12th digit) Setting provided Setting provided + tag Tag (Mounting method) (13th digit) Pipe mount Wall mount FLSE 2 E Description Version (4th digit) Standard Type (5th and 6th digits) Small diameter detector (25 to 100mm) Small detector (50 to 225mm) coustic coupler (7th digit) (Note) Silicone rubber Silicone-free grease Optional specification (10th digit) Tag V method Note: Normally silicone rubber is selected as an acoustic couplant. Silicone rubber is provided in a tube (100g). If you place an order for several units, 1 tube may suffice for every 5 units. Select silicone-free grease for semiconductor equipment or similar that is vulnerable to silicone. The silicone-free grease is water-soluble and cannot therefore be used in an environment exposed to water or on piping subject to condensation. Since the grease does not set, periodic maintenance (cleaning, refilling every about 6 months at normal temperatures) is necessary. Note: Select silicone grease for Teflon-coated piping FLW C D E F G H J K L M N P Q R Z 2 Description Type (4th, 5th and 6th digits) Small sensor, submersible type (50 to 400) Small sensor, submersible type* 2 (50 to 400) Middle sensor, submersible type (200 to 1200) Large sensor, submersible type (200 to 6000) Large sensor, submersible type* 2 (200 to 6000) Optional specification (7th digit) Tag indication provided Signal cable (9th and 10th digits) 10m Others Mounting method (11th digit) Standard Z method mounting (for small sensor) V method V or Z method 2: For old pipes, cast iron pipes, mortar lining pipes or others, through which ultrasound signal cannot easily be transmitted, select FLW11 or FLW50. 5: Silicone rubber (KE-348W) is provided as a standard acoustic couplant FLW 2 Description Type (4th, 5th and 6th digits) Small sensor, submersible type (50 to 250) Small sensor, submersible type* 2 (50 to 250) Middle sensor, submersible type (200 to 1200) Large sensor, submersible type (200 to 6000) Large sensor, submersible type* 2 (200 to 6000) Optional specification (7th digit) Tag indication provided Mounting method (11th digit) Standard Z method mounting (50 to 400 for small sensor) 2: For old pipes, cast iron pipes, mortar lining pipes or others, through which the ultrasound signal cannot easily be transmitted, select FLW11 or FLW50. 5: Silicone rubber (KE-348W) is provided as a standard acoustic couplant F LD S S Description Type (4th, 5th and 6th digits) Small diameter sensor (13 to 100) V method High-temperature sensor *1 (50 to 400) V or Z method elt, acoustic couplant (7th digit) For fixed type Coaxial cable (9th digit) V method V or Z method 1: For turbid fluid, old pipes, cast iron pipes, mortar lining pipes or similar, through which the ultrasound signal cannot easily be transmitted, use the guide rail TK4C6164C1 (optional) and mount the sensor using the Z method. 5: Silicone rubber (KE-348W) is provided for small diameter sensors and high-temperature grease (KS62M) for high-temperature sensors as a standard acoustic couplant.
6 Specifications
7
8 Meter U-bolt (M8) (option) Mounting Pipe (2) Mounting plate SS tag (option) TIME DELT-C ESC ENT 9 Mounting hole 9x Earth terminal (M4) C power supply 1 L 2 N to 240VC 50/60Hz DO1 TR out DO2 TR out Max. 30VDC, 0.1 DO3 REL I out Max. 240VC/ 30VDC, 1 DC power supply to 30VDC 10 GND To the upstream-side sensor HF1 GND HF2 *1 SH To the downstream-side sensor *1 Only for double shield cable (type FL8, 9) *1 SH Cable gland 153 Option DI1 SHILD TXDR2 TXDR1 1 DI1 2 3 GND RXD 4 TXD Earth terminal (M4) For sensor cable (PF3/8) For power supply/output cable (PG13.5) Status input RS-485 RS-232C Status input M3 screw SS tag (option) Sensor NC connector Frame L Spacing (djustment by every 3mm) Lock clip H Type Pipe size (mm) L FLSE12 25 to 100 FLSE22 50 to H Spacing 21 to to 240 Mass approx.(kg) Sensor Nameplate Spacing (0 to 270) 72 Pipe 500 Frame end GND terminal Scale (inch) Scale (mm) 33 Saddle Saddle 40 Chain & spring Spacing (0 to 330) Cursor NC connecter Element holder 33 Lock nut 33 90max 205max 530 Spacing (0 to 133) Scale (inch) Cursor 52.5 Scale (mm) NC connecter Lock nut Element holder max Wire rope Wire rope 62 Fuji Electric our distributor: Coulton Instrumentation Ltd 17 Somerford usiness Park, Christchurch, H23 3RU, UK Tel: sales@coulton.com Web:
Fuji Ultrasonic Flowmeter Series
Fuji Ultrasonic Flowmeter Series 21A1-E-0008 Features of ultrasonic flowmeter in flow rate measurement 1. Total cost reduction allowed by elimination of piping installation 2. Can be installed even while
More informationULTRASONIC FLOWMETER < >
SERIES ULTRSONIC FLOWMETER < > DT SHEET FS, FLS/FLW/FLD This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electronics and digital
More informationULTRASONIC FLOWMETER < M-Flow>
ULTRSONIC FLOWMETER < M-Flow> DT SHEET FLR, FLS, FL This meter is a clamp-on type ultrasonic flowmeter for permanent use based on transit time measuring method. This flowmeter is designed to be suitable
More informationInstruction Manual ULTRASONIC FLOWMETER. TYPE: FSV (Flow transmitter) FLS, FLW, FLD (Detector) FLY (Signal cable) INF-TN1FSVG-E
Instruction Manual ULTRASONIC FLOWMETER TYPE: FSV (Flow transmitter) FLS, FLW, FLD (Detector) FLY (Signal cable) INF-TN1FSVG-E Introduction We thank you very much for purchasing Fuji Electric s ultrasonic
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationInstruction Manual. mass flow meter for compressed air. Druckluftbilanzierungssystem VARIOMASS VARIOMASS DIELEN MENU MAX ENTER EXIT MAX ENTER MENU
Instruction Manual mass flow meter for compressed air Druckluftbilanzierungssystem VARIOMASS VARIOMASS DIELEN K1 K2 1 2 3 MENU 4 5 6 MAX 7 8 9 i 0. EXIT ENTER VARIOMASS DIELEN K1 K2 1 2 3 4 5 6 MAX ENTER
More informationSITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview
Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationProcess Protection Acoustic sensors for pump monitoring
coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement
More information+GF+ SIGNET Temperature Transmitter Instructions
GF SIGNET 80- Temperature Transmitter Instructions ENGLISH -80.090- B-/00 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal
More informationPanaFlow HT. Panametrics Ultrasonic SIL Flow Meter for Liquids. GE Measurement & Control. Applications. Features & Benefits
GE Measurement & Control PanaFlow HT Panametrics Ultrasonic SIL Flow Meter for Liquids pplications PanaFlow HT is a SIL-rated flow meter used for flow measurement of liquids in either nominal or extremely
More informationAdvancements in Clamp-on Ultrasonic Flow Measurements Biosolids Workshop December 1 st 2016
Advancements in Clamp-on Ultrasonic Flow Measurements 2016 Biosolids Workshop December 1 st 2016 Market Leader in Clamp-On Ultrasonic Flowmeters with >50,000 instruments sold Background Information Extraordinary
More informationModel Sono-Trak Transit Time
Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic
More informationULTRASONIC FLOW METER FT101
Introduction F t101 is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp on type ultrasonic flowmeter is easy to install and no need to cut off the pipe, that
More informationTechnical specification FLUXUS WD
Technical specification FLUXUS WD Non-invasive ultrasonic flow measurement on buried pipes Permanently installed clamp-on ultrasonic flow measurement system for buried water and wastewater pipes Features
More informationIntroduction. Note. Described in the nameplate put on the main body. Product nationality:
Introduction We thank you very much for purchasing Fuji Electric s ultrasonic flow meter. The instruction manual concerns the installation, operation, checkup and maintenance of the Flow transmitter (FSV)
More informationPreset counters, electronic
The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their
More informationF-3200 SERIES Inline Electromagnetic Flow Meter Wiring Instructions
F-3200 SERIES Inline Electromagnetic Flow Meter Wiring Instructions ELECTRICAL INSTALLATION Input Power Requirements F-3000 Electromagnetic Flow Meters equipped with standard transmitters are available
More informationThermoPLUS Smart Temperature Transmitter
No. SS2-TT110-0100 ThermoPLUS Smart Temperature Transmitter Model TT61/71 (Integral Sensor type) OVERVIEW The models TT61/71 Smart Transmitter are temperature transmitters for the model TT90 integral temperature
More informationSERIES < > ULTRASONIC FLOWMETER
DT SHEET SERIES < > ULTRSONI FLOWMETER FSV-2, FSS, FL This flowmeter is a clamp-on type ultrasonic flow meter based on transit-time measuring method. Making full use of the latest electronics
More informationULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement
ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp
More informationEfcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK
Efcon Water Installation & User Manual Electro Magnetic Flowmeter (EMF) Page 1 Table of content Page 1.1 General 3 1.2 Application area 4 1.3 Transportation 4 1.4 Principle of Operation 4 1.5 Product Description
More informationTechnical data. Standards: IEC/EN thermoplastic Protection class: IP 67 to EN Termination: cable LiYY 2 x 0.25 mm 2, length 1 m
B 6,5 3,5 4 44 33,5 13 4 00 Flat design on-contacting principle 1 Reed contact ctuating distance up to 60 mm depending on actuating magnet and version ctuating surface marked by protrusion Pre-wired cable
More informationThin Film Deposition
Thin Film Deposition Section Eleven 11 11.1 General Information 2 11.2 Deposition Monitors 3 11.3 Crystal Feedthroughs 4 11.4 Crystal s 5 11.5 Cables, s, Crystals & Accessories 6 Nor-Cal Products, Inc.
More informationGeneral Specifications
General Specifications US300FM Ultrasonic Flowmeter GS 01G05B03-01E GENERAL The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing
More informationThin Film Deposition
Thin Film Deposition Section Eleven 11 11.1 General Information 2 11.2 Deposition Monitors 3 11.3 Crystal Feedthroughs 4 11.4 s 5 11.5 Cables, s, Crystals & Accessories 6 Nor-Cal Products, Inc. 1967 South
More informationGeneral Specifications
General Specifications US300FM Ultrasonic Flowmeter GS 01G05B03-01E GENERAL The model US300FM is an ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the advanced signal processing
More informationHigh Accuracy Positioning Sensors EG Series Features
High ccuracy Positioning s EG Series Features Ultra-small sensor head Non-contact, stable detection in wide temperature range Highly stable amplifier provides 1 µm. Mil repeatability Hi/Lo tolerance detection
More informationEGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification
EGCW Converter for Electromagnetic Flowmeter GENERAL MAGMAX EGCW is the high-performance separate type converter for electromagnetic flowmeters with the compact housing. Improved self-diagnostic functions
More informationIntroduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter
Field Intelligent Device Series Electromagnetic Flowmeter Converter LF620,LF622 Introduction Combined with a multi-functional converter LF620 (combined type) or LF622 (separate type) equipped with its
More informationAmbient Conditions. Operating Conditions. Pressure
Temperature Relative Humidity -20 C +75 C 0% 100 RH to 65 C non condensing 86 106 bar 4.0MPa (DN10 DN80) 1.6MPa (DN100 DN150) 1.0MPa (DN200 DN1000) Remote version < 80 C (rubber coating) Compact version
More informationUser s Manual CM2-MGR nd edition
MagneW 3000 Electromagnetic Flowmeter Hyper-Fill Model: MGR13C (Converter) MGR11U (Detector) User s Manual CM2-MGR100-2001 2nd edition Copyright, Notices and Trademarks 2005-2012 Azbil Corporation All
More informationUltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER
UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER DESCRIPTION The UltraFlo UFDD Clamp-On Ultrasonic Flow Meter is the ideal flow meter with accurate, easy-to-use, easy-to-install digital doppler technology.
More informationTechnical Specification FLUXUS ADM 8x27
Ultrasonic Flow Measurement of Liquids in Explosive Atmosphere Features Transducers non-invasive (no contact with the medium, no need for expensive materials) wearfree no pressure drop (no operational
More informationDigital conductivity transmitter
Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due
More informationApplications Features
GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system
More informationDissolved Oxygen Transmitter
Dissolved Oxygen Transmitter OBM-67H The OBM-67H is a -wire type (4VDC power supply) dissolved oxygen transmitter housed in a robust, die-cast aluminum enclosure suitable for installation out in the field.
More informationUltrasonic level meters ULM 70
průmyslová elektronika Ultrasonic level meters ULM 70 For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels, drains, etc.
More informationValve Island with Electronic I/O
Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication
More informationTechnical specification FLUXUS F401 H2O
Technical specification Ultrasonic flowmeter for water Portable, very robust and easy-to-use ultrasonic flowmeter for the water and wastewater industry Features Very high bi-directional measuring accuracy
More informationIndustrial Conductivity (Electric Conductivity) Detector
Industrial Conductivity (Electric Conductivity) Detector / (General Multi-Purpose Use) R/R (Compact Ultra-Pure Water Use) S (Intrinsically Safe) The -electrode type industrial conductivity (electric conductivity)
More informationAdvancements in Clamp-on Ultrasonic Flow Measurements. Ohio Section AWWA SE District Fall Meeting September 1 st 2017
Advancements in Clamp-on Ultrasonic Flow Measurements Ohio Section AWWA SE District Fall Meeting September 1 st 2017 About Us - Providing Measurement instrumentation and data collection since 1984 - State
More informationModus M Series. General Eastern Differential Pressure Transmitters. GE Sensing
The Modus M Series family of differential pressure transmitters measure low pressures, and feature a variety of analog signal outputs with low power consumption. A wide selection of standard pressure ranges
More informationFlow Meter FC100. Description FC100. Ordering information
Flow Meter FC00 Microcontroller operated Flow Meter to monitor and display flow rates and temperature. Once correctly adjusted it can also be used for mass flow measurements. Factory preset for air and
More informationFlow Measurement SITRANS F US Clamp-on
Overview SITS FUH1010 clamp-on non-intrusive ultrasonic flowmeter is ideal for applications carrying crude oil, refined petroleum or liquefied gas. SITS FUH1010 has three application areas: Interface detectors,
More informationSignet Flow Transmitter
Signet 80- Flow *-80.090-* English -80.090- Rev. L 0/ English WARNING! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.
More informationMineral-insulated resistance thermometers to EN
Data Sheet 90.2221 Page 1/6 Mineral-insulated resistance thermometers to EN 60 751 for temperatures from -50 (-200) to +600 C flexible sheath with shock-protected sensor as single or twin resistance thermometer
More informationES Series Features Detecting distance twice that of conventional
Long-distance Separate-amplifier Series Features Detecting distance twice that of conventional sensors Detecting distance easily adjustable Wide range of sensor head types available Built-in alarm output
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI
Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is
More informationRefer to manual. Failure to read message could result in personal injury or serious damage to the equipment or both.
CERAVAC Transmitter CTR 100 N Short form manual 300544675_002_C0 Part numbers: 230 300V02 230 310V02 230 301V02 230 311V02 230 302V02 230 312V02 230 303V02 230 313V02 230 304V02 230 314V02 230 305V02 230
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner
ClampOn, Inc. Ultrasonic Intelligent Sensors Presented by Hans A. Wagner Bergen, Norway Locations Project Management Engineering and Manufacturing Research and Development Sales and Service for Eastern
More informationDissolved Oxygen Transmitter (For Low-Concentration Measurement) OBM-165H
Dissolved Oxygen Transmitter (For Low-Concentration Measurement) OM-65H The OM-65H is a -wire type (4VDC power supply) dissolved oxygen transmitter (for Low-Concentration Measurement) housed in a robust,
More informationIS-3000 SERIES INFRARED SCANNER
IS-3000 SERIES INFRARED SCANNER NON-CONTACT, RELIABLE, PRECISE, LONG RANGE POSITIONING FOR HOT OR COLD PRODUCTS FEATURES ANALOG AND DIGITAL OUTPUTS INDICATIVE OF TARGET POSITION, WIDTH AND TEMPERATURE
More informationRHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits
RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog
More informationDigital batch controller
INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationKMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display
KMS101W Electromagnetic Wafer Flowmeters with S100 display ideal as resettable/batching meter (sizes: 15mm to 150mm) 0BFEATURES For ADMIXTURE Batching, Shotcrete, Mild-Recycled Water & Selected Chemical
More informationPaddle wheel flow controller for On/Off control
addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs
More informationSolid State Pressure Sensors D8M
Solid State Pressure Sensors D8M Solid State Pressure Sensors with Analog, Pulse or Frequency Outputs Compact housing measures 30L x 30W x 12.4H mm. Accept 4 mm OD tubing (D8M-A1, -R1); 3 mm OD tubing
More informationCEC VIBRATION TRANSMITTER
CEC 1-808 VIBRATION TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com E-mail:
More informationNew Servo Concept: Junma
New Servo Concept: Junma Junma uses the world s premier servo technology to provide unmatched performance with a quick and efficient setup. This totally new plug and play design concept requires no parameter
More informationMaxxFlow HTC Flow Measurement for Dry Bulk Solids
EN MaxxFlow HTC Flow Measurement for Dry Bulk Solids Manufactured by Product Information www.onthelevel.com MaxxFlow HTC MaxxFlow HTC MaxxFlow HTC Product Information Use The MaxxFlow HTC was developed
More informationUltrasonic Level Transducer Type: MPUL06 Article No.: ca. 122
Type: Article No.: 0067720.006 Dimensions ø95 PG7 45.25 16 101 ca. 122 ø53 NPS 2" Figure 1: Ultrasonic Level Transducer Description and application The MPULxx is an ultrasonic transducer used for determining
More informationFLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual
SWITCH 600 Series Velocity Flow Sensor Instruction Manual Ultrasonic Velocity Sensor using Doppler Technology Model: FS-600 Manual Release Date: November, 2009 ECHO Process Instrumentation, Inc. CONTENTS
More informationFH CMF Coriolis Mass Flow Meters
FH CMF Coriolis Mass Flow Meters 1. Introduction Coriolis Mass Flow Meters patented and developed by our company (Chinese Patent No. 03119685.3, 03149996.1) are the leading meters for precision flow measurement.
More informationDigitalFlow TM CTF878
DigitalFlow TM CTF878 Panametrics Correlation Tag Clamp-On Gas Ultrasonic Flow Meter Applications The DigitalFlow CTF878 clamp-on gas fl ow meter is a complete ultrasonic fl ow metering system for the
More informationUFM 800 W, C Ultrasonic flowmeter for water and wastewater
KROHNE 08/2000 7.02343.21.00 GR/PRINTO, C Ultrasonic flowmeter for water and wastewater...with weld-in sensors for metal pipelines...withbuilt-on or built-in sensors for open channels Variable area flowmeters
More informationFlow Measurement SITRANS F M. Flow sensor MAG /49. Overview
Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical
More informationCMM System - Encapsulated Modules
CMM System - Encapsulated Modules Bearing Monitoring BMM-40 BDM-40 BMM-42 BDM-42 DMM-13 DMM-12 SPM 40000 SPM 42000 45011-L (max. 4 m) 45011-L (max.100 m) VMM-14/15 VMM-20/21 VDM-14/15 VDM-20/21 90296-L
More informationMICROWAVE BRIX SENSOR. onexis automations pvt ltd
MICROWAVE BRIX SENSOR oneis automations pvt ltd SI ENERGY VENTURS PVT. LTD. Basic Operating Principles of the HK Microwave System The HK Systems use a microwave signal to determine the BRIX of all kind
More informationMost Suitable for a Variety of High-precision Displacement Measurements. Regular Reflective Sensors. Line Beam Sensors.
/ Length (2D CMOS Laser Type) Advanced Functions Integrated into a Compact Sensor for Easy Handling of High-grade Applications A Controller the size of a business card combined with the smallest Sensor
More informationGS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit
High performance microflow Coriolis Flowmeter GENERAL SPECIFICATION GS.No. GENERAL Based on the Coriolis technologies accumulated over many years, the OVAL has broadened its current general purpose coriolis
More informationModel Q40CT. System Features. Toroidal Conductivity Monitor...
ATI s Model Q40CT toroidal conductivity system is designed for on-line monitoring of chemically aggressive process solutions. This blind, analog version is ideally suited for applications where reliable
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationLevel Lance Model 5100
Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection
More informationKMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)
KMS502F Electromagnetic Flanged Flowmeters (sizes: 25mm to 200mm) FEATURES: For all your water applications including batching. Flanged connection suites ANSI 150lb flanges. Unsurpassed accuracy to ±0.5%
More informationHD48V01T HD48V17T HD48V77T. [ GB ] Temperature, Relative humidity and Dew Point transmitters
H4801T H48V01T H4817T H48V17T H4877T H48V77T [ GB ] Temperature, Relative humidity and ew Point transmitters [ GB ] [ GB ] escription H48.. series of transmitters measure temperature, relative humidity
More informationAUTOMATION. Operator s Manual. ACF-10 Series Acoustical Flow Sensor for Solids. Rev. 1a, 2/03
AUTOMATION P R O D U C T S G R O U P, I N C. Operator s Manual Acoustical Flow Sensor for Solids Tel: 1/888/525-7300 Fax: 1/435/753-7490 www.apgsensors.com E-mail: sales@apgsensors.com Table of Contents
More informationPowersafe Termination Guide
Powersafe Termination Guide Contents Index 1. Introduction 2. Overview 3. Termination Methods 3.1 Set screw termination 3.2. Recommended Assembly Procedure for Panel Mounted Connectors 3.3. Crimp Termination
More informationMS 5000 CIAO SENSOR EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM
CIAO SENSOR MS 5000 EXTREMELY EASY TO INSTALL THANKS TO PATENTED WRAPPER FIXING SYSTEM Warranty conditions are available on this website: www.isomag.eu only in English version INDEX TECHNICAL DATA... 3
More informationeye in hell CD 3002 Sensor Manual
Your eye in hell CD 3002 Sensor Manual Siemens Laser Analytics AB Oct 2001 CD 3002 Sensor manual Document number: CID 3002-1102 Rev. 2A LDS 3000 Sensor manual Content Content 1. CD 3002 1 1.1 General 1
More informationM-2111 Series Ultrasonic Flow Meter
M-2111 Series Ultrasonic Flow Meter High Accuracy/Non-contact Flow Sensing in PFA Key Features Accuracy ± 1% of reading Repeatability ± 0.5% of reading All wetted parts made of New PFA (AP- 211SH) Contamination
More informationTechnical Specification FLUXUS ADM 8127B
FLUXUS ADM 8127B Liquid Ultrasonic Flowmeter for Permanent Installation in Hazardous Areas in the Mining Environment FLUXUS ADM 8127B is especially designed for the stationary use in explosive atmosphere
More informationManostar Electronic Low Differential Pressure Measurement System
Manostar Electronic Low Differential Pressure Measurement System Manosys Presure Transmitter Intrinsically safe apparatus type Explosion-proof performance iag Intrinsically-safe apparatus is called by
More informationF5 Feedback Unit. PMV F5 Feedback unit Product Information. A Flowserve Company
PMV F5 Feedback unit Product Information A Flowserve Company For position feedback, the F5 unit offers the ability to very simply add switches (mechanical or proximity), a potentiometer or a 4 20 ma transmitter
More informationWATERFLUX 3000 Quick Start
WATERFLUX 3000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS WATERFLUX 3000
More informationMass and Volume Flow Transmitter
IFT9701 Product Data Sheet PS-00218-EU December1999 Mass and Volume Flow Transmitter IFT9701 transmitter The IFT9701 microprocessor-based transmitter works with Micro Motion sensors to provide affordable,
More informationAir flow meter For ventilation and air-conditioning Model A2G-25
Flow ir flow meter For ventilation and air-conditioning Model 2G-25 WIK data sheet SP 69.04 for further approvals see page 5 pplications For measuring the air flows of radial ventilators For measuring
More informationDMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)
DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- 0005/ DMRC-E-TR-TRANSF-05 SPECIFICATIONS FOR THREE PHASE 33 kv/415 V AUXILIARY Issued on: Date
More informationDigital Fiber-Optic Switches
CP-PC-2259E Digital Fiber-Optic Switches Model HPX-EG0 0/01 : Standard Model HPX-EG/ 51 : Long-dis tance Sensing Satisfaction Freedom from Frequent Adjustments Please read Terms and Conditions from the
More informationSmart Electromagnetic Flowmeter Open channel Flowmeter Detector
No. SS2-MGN200-0200 MagneW3000 PLUS Smart Electromagnetic Flowmeter Open channel Flowmeter Detector Model NNK150/951 OVERVIEW The MagneW3000 PLUS Electromagnetic Flowmeter is submersible type of flowmeter
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationHow to Order Manifold. Manifold mounting. DIN rail mounting style Direct mounting style
Plug Lead Unit Series 000 [Option] How to Order Manifold S 0 FD D Electrical entry F kit D-sub connector kit P kit Kit type Flat ribbon cable connector kit J kit Flat ribbon cable (0P) (PC Wiring System
More informationFGM 160 Ultrasonic Flaregas meter. Flare Gas Measurement
Fluenta Overview FGM 160 Ultrasonic Flaregas meter Flare Gas Measurement Why Measure Flare Gas? Flare systems at offshore production platforms, refineries and chemical plants are primarily installed for
More information6GHz Intelligent Radar Level Meter Product Manual. Model:KRD520 SERIES
6GHz Intelligent Radar Level Meter Product Manual Model:KRD520 SERIES Directory 1 Product Overview...1 2 Product Introduction...2 3 The Installation Requirements...4 4 The Electrical Connection...6 5 Instrument
More informationINTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:
Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:
More informationUser Friendly Interface means: Power through Simplicity
W h a t i s t h e T & D T R - 5 i S e r User Friendly Interface means: Power through Simplicity The TR-5i Series is a family of data loggers designed to measure and record a variety of items: from temperature
More informationRelease A Member of the
Release 4.02 A T u n e d GRID M e a s u r e A Member of the GRID GRID The OCTAVE Ultrasonic Meters A revolutionary, precise and ultra reliable ultrasonic bulk water meter with no moving parts. With superior
More informationDigital flowmeter for continuous flow measurement
8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration
More information