This document contains TDS for the following products: ReneSola Australia Virtus II Module W 4BB

Size: px
Start display at page:

Download "This document contains TDS for the following products: ReneSola Australia Virtus II Module W 4BB"

Transcription

1 This document contains TDS for the following products: Virtus II Module 55-70W 4BB ReneSola Australia Virtus II Module 60-70W 4BB Virtus II Module 55-70W 4BB 1000V US

2 Virtus II Module 55W 60W 65W 70W High Module Conversion Efficiencies Easy Installation and Handling for Various Applications Mechanical Load Capability of up to 5400 Pa Con Conforms with IEC 6115:005, IEC 61730: 004, UL 1703 PV Standards ISO9001, OHSAS18001, ISO14001 Certified Safety Application Class A, Safety Class II, Fire Rating C Fire Also Applicable for Module with Black Frame ee Performance Figures in % ant r Gua 100%,5% 97 95% Adde material & workmanship d Va 90% lue 85%,0% 80 80% 0% linear power output YEAR C UL CM US LISTED C US Intertek TUV NORD CERT GmbH IEC / / ReneSola.com

3 Virtus II Module 55W, 60W, 65W, 70W Dimensions I-V Curves 99mm 40mm 949mm 4-7.5X7.5/ DRAIN HOLE JUNCTION BOX W/m LABEL 800W/m Current (A) 6 860mm 1360mm 1640mm 1000mm 8-4 GROUNDING HOLE 600W/m 4 400W/m 00W/m x10 INSTALLING HOLE X3.5 VENT HOLE Voltage (V) Drawing Only for Reference JC55M-4/Bbs JC60M-4/Bbs JC65M-4/Bbs Maximum Power (Pmax) 55 W 60 W 65 W 70 W Power Tolerance Module Efficiency 15.7% 16.0% 16.3% 16.6% Maximum Power Current (lmp) 8.39 A 8.53 A 8.66 A 8.71 A Maximum Power Voltage (Vmp) 30.4 V 30.5 V 30.6 V 31.0 V Short Circuit Current (lsc) 8.86 A 8.95 A 9.03 A 9.10 A Open Circuit Voltage (Voc) 37.5 V 37.6 V 37.7 V 38.1 V JC55M-4/Bbs JC60M-4/Bbs JC65M-4/Bbs JC70M-4/Bbs Maximum Power (Pmax) 189 W 193 W 196 W 00 W Maximum Power Current (lmp) 6.63 A 6.74 A 6.84 A 6.87 A Maximum Power Voltage (Vmp) 8.5 V 8.6 V 8.7 V 9.1 V Short Circuit Current (lsc) 7.0 A 7.7 A 7.33 A 7.37 A Open Circuit Voltage (Voc) 35.1 V 35. V 35.3 V 35.6 V JC70M-4/Bbs Values at Standard Test Conditions STC (AM1.5, Irradiance of 1000W/m, Cell Temperature 5oC) Values at Normal Operating Cell Temperature, Irradiance of 800W/m, AM1.5, Ambient Temperature 0oC, Wind Speed 1m/s. Cell Type Virtus II (Polycrystalline) 156 x156 mm, 60 (6x10) pcs in series Temperature Coefficient of Voc -0.30%/oC Glass High Transmission, Low lron, Tempered Glass Temperature Coefficient of Isc 0.04%/oC Frame Anodized Aluminum Alloy Temperature Coefficient of Pmax -0.40%/oC Junction Box IP65/IP67 Rated, With Bypass Diodes Nominal Operating Cell Temperature (NOCT) 45oC +_ oc Dimension *1640 x 99 x 40 mm Output Cable 4 mm (EU)/1 AWG (US), 1000 mm Weight 19 kg Installation Hole Location See Drawing Above Container 0 GP 40 GP 40 HQ Operating Temperature Pallets per Container Maximum System Voltage Pieces per Container 300/31 700/78 770/798 Maximum Series Fuse Rating -40oC ~ +85oC 1000VDC (EU) / 1000VDC (US) 0A (EU) / 0A (US) Rev No: JC/TDS/ *Contact Renesola for tolerance specification CAUTION: All rights reserved. Design and specification are subject to change without prior notice. ReneSola.com

4

5

6 CM TUV NORD CERT GmbH Virtus II Module 55W/60W/65W/70W High Module Conversion Efficiencies Easy Installa on and Handling for Various Applica ons Mechanical Load Capability of up to 113 psf (5400 Pa) Conforms with IEC 6115:005, IEC 61730: 004, UL 1703 PV Standards ISO9001, OHSAS18001, ISO14001 Cer fied Safety Fire Applica on Class A, Safety Class II, Fire Ra ng Type 1 Also Applicable for Module with Black Frame Guarantee Performance Figures in % 100% 95% 90% 85% 80% 0% ,5% Added Value ,0% material & workmanship linear power output YEAR C Intertek US IEC 6115 / / ReneSola.com

7 Virtus II Module 55W/60W/65W/70W Dimensions I-V Curves 39.1 inches 1.6 inches 37.4 inches JUNCTION BOX 4-0.3ʺX0.3ʺ/ DRAIN HOLE W/m LABEL 8 800W/m 64.6 inches 39.4 inches -Ø0.16ʺ GROUNDING HOLE 33.9 inches 53.5 inches Current (A) W/m 400W/m 00W/m 8-0.5ʺX0.39ʺ INSTALLING HOLE ʺX0.14ʺ VENT HOLE Voltage (V) Drawing Only for Reference JC55M-4/Bbs JC60M-4/Bbs JC65M-4/Bbs JC70M-4/Bbs Maximum Power (Pmax) 55 W 60 W 65 W 70 W Power Tolerance Module Efficiency 15.5% 16.0% 16.3% 16.6% Maximum Power Current (lmp) 8.39 A 8.53 A 8.66 A 8.71 A Maximum Power Voltage (Vmp) 30.4 V 30.5 V 30.6 V 31.0 V Short Circuit Current (lsc) 8.86 A 8.95 A 9.03 A 9.10 A Open Circuit Voltage (Voc) 37.5 V 37.6 V 37.7 V 38.1 V Values at Standard Test Condi ons STC (AM1.5, Irradiance of 1000W/m, Cell Temperature 77 o F) JC55M-4/Bbs JC60M-4/Bbs JC65M-4/Bbs JC70M-4/Bbs Maximum Power (Pmax) Maximum Power Current (lmp) Maximum Power Voltage (Vmp) Short Circuit Current (lsc) Open Circuit Voltage (Voc) 189 W 6.63 A 8.5 V 7.0 A 35.1 V 193 W 6.74 A 8.6 V 7.7 A 35. V Values at Normal Opera ng Cell Temperature, Irradiance of 800W/m, AM1.5, Ambient Temperature 68 o F, Wind Speed 1m/s. 196 W 6.84 A 8.7 V 7.33 A 35.3 V 00 W 6.87 A 9.1 V 7.37 A 35.6 V Cell Type 6 inches Virtus II (Polycrystalline), 60 (6x10) pcs in series Temperature Coefficient of Voc %/ o F (-0.30%/ o C) Glass High Transmission, Low lron, Tempered Glass Temperature Coefficient of Isc 0.0%/ o F (0.04%/ o C) Frame Anodized Aluminum Alloy Temperature Coefficient of Pmax -0.%/ o F (-0.40%/ o C) Junc on Box IP65/IP67 Rated, With Bypass Diodes Nominal Opera ng Cell Temperature (NOCT) 113 ± 3.6 o F (45 ± o C) Dimension *64.6 x 39.1 x 1.6 inches Output Cable 1 AWG, 39.4 inches Weight 41.9 Ibs Installa on Hole Loca on See Drawing Above Container Pallets per Container Pieces per Container 0 GP 1 300/31 40 GP 8 700/78 40 HQ 8 770/798 Opera ng Temperature Maximum System Voltage Maximum Series Fuse Ra ng -40 o F ~ +185 o F (-40 o C ~ +85 o C) 1000VDC (US) 0A (US) Rev No: JC/TDS/ *Contact Renesola for tolerance specifica on CAUTION: All rights reserved. Design and specifica on are subject to change without prior no ce. ReneSola.com

8 Contacts: Global Headquarters & Asia Add: 15F, Manpo int l Plaza, No. 500, West Yan an Road, Shanghai, China T: F: E: services@renesola.com Australia Add: 51 Barry Street, Bayswater Victoria 3153, Melbourne T: E: marketingaus@renesola.com Europe Add: Lyoner Straße Frankfurt am Main, Germany T: +49 (0) E: services@renesola.com Africa Add: Unit, Rambo Junction, 400 Roan Crescent, Midrand, 1685, South Africa T: (+7) E: supportza@renesola.com Americas Add: 1300 Clay Street, Suite 550, Oakland, CA 9461 T: +(415) E: marketing.us@renesola.com

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty Those who dream of a better future can help lead to a more meaningful and enriched world. As a leading solar module manufacturer in Korea, we never stop to achieve competitiveness through differentiation,

More information

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof EN LG300N1K-G4 60 cell LG s new module, NeON 2 Black, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to enhance power output and reliability. NeON 2 Black demonstrates

More information

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range Growatt 2000TL Maximum efficiency of 97% and wide inpunt voltage range Internal DC switch Transformerless GT topology Compact design Multi MPP controller MTL - String Bluetooth / RF technology / ZigBee

More information

APPENDIX V PRODUCT SHEETS

APPENDIX V PRODUCT SHEETS National Institutes of Health Building 37 Modernization Bethesda, Maryland APPENDIX V PRODUCT SHEETS Katie L. McGimpsey Mechanical Option 1 of 4 BP 4160 160-Watt Monocrystalline Photovoltaic Module The

More information

KIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador

KIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador KIT SOLAR ANET O 7500 Wh/día QUÉ PUEDES CONECTAR? QUÉ INCLUYE? 9 Módulos FV T RINA SOLAR 255Wp Policristalino (3 Estructuras incluidas) 24 Baterías T URBO ENERGY 8 SOPZS 1400 1 Inversor/cargador/regulador

More information

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years

More information

Upsolar Smart Modules

Upsolar Smart Modules Upsolar Smart Modules Optimized by Energy Improve ROI with No Upfront Cost Smart Modules optimized by Energy deliver more energy, active management and enhanced safety through state-ofthe-art module-embedded

More information

Your Origin SLIVER system will be supplied with one of the following sets of panels:

Your Origin SLIVER system will be supplied with one of the following sets of panels: SLIVER3000 Solar System Panel Specifications Your Origin SLIVER system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum

More information

Quality criteria and certificates

Quality criteria and certificates Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years

More information

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES TM FULL RANGE OF CERTIFIED MODULES Mono Crystalline Watt to 50 Watt Poly (Multi) Crystalline Watt to 80 Watt Glass Cells High Efficiency A-Grade

More information

How to Evaluate PV Project Energy Yield

How to Evaluate PV Project Energy Yield How to Evaluate PV Project Energy Yield There are three main characteristics of a PV module that could affect the real energy generation of a PV plant: Temperature coefficient; Low light performance; IAM

More information

Sunny Smile with Hyundai

Sunny Smile with Hyundai Happy Energy for the Future! Sunny Smile with Hyundai Advanced Green Solution beyond the world Hyundai Heavy Industries Happy Energy for the Future Hyundai Heavy Industries provides green solution for

More information

TECHNICAL DATA SHEET. smartflower POP. As of: August 2015 Typing and printing errors reserved.

TECHNICAL DATA SHEET. smartflower POP. As of: August 2015 Typing and printing errors reserved. TECHNICAL DATA SHEET smartflower POP. TECHNICAL DATA POWER OUTPUT Nominal output Output through 2-axle tracking POP 2.31 kwp* 3.400 5.700 kwp/a** SYSTEM Modultype Modul power output warranty Module product

More information

1MW - Gangneung, S.Korea BEYOND YOUR EXPECTATIONS TOP CLASS. topsun.kr

1MW - Gangneung, S.Korea BEYOND YOUR EXPECTATIONS TOP CLASS. topsun.kr 1MW - Gangneung, S.Korea BEYOND YOUR EXPECTATIONS TOP CLASS topsun.kr About Topsun Strategy Our people are key to success. As a gloabl solar This applies to every It s based on our vision The focus lies

More information

Understanding Temperature Effects on Crystalline PV Modules

Understanding Temperature Effects on Crystalline PV Modules Understanding Temperature Effects on Crystalline PV Modules The following is a discussion on temperature and how it affects solar module voltages and power output. This is particularly important in solar-battery

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002 Bangalore, May 2017 Certificate No. T -1543 2 / 17 Contents CONTENTS... 2

More information

Page 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37

Page 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37 Page 1 of 37 Test Report issued under the responsibility of: TEST REPORT IEC 61215 PV Module Safety Qualification Requirements for testing Report Reference No.... : ULI-NABL(ELT)-MNRE-0053/2011 Date of

More information

Application Note: String sizing Conext CL Series

Application Note: String sizing Conext CL Series : String sizing Conext CL Series 965-0066-01-01 Rev A DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This Application Note is in addition to, and incorporates by reference, the installation

More information

TEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval

TEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval Test Report issued under the responsibility of: TEST REPORT IEC 61215: 2005 2nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval Report Reference

More information

Test Report. File No.: SHV01032/18-02 Test Report No.:

Test Report. File No.: SHV01032/18-02 Test Report No.: File No.: SHV01032/18-02 No.: 492011003.001 Applicant... : Manufacturer 1... : Manufacturer 2... : Order No.... : Suzhou Akcome Optronics Science &Technology Co., Ltd. Jintang Rd, Zhangjiagang Economic

More information

mono-crystalline silicon solar cells mm No. of cells and connections 72(6 12)

mono-crystalline silicon solar cells mm No. of cells and connections 72(6 12) Rated Maximum Power (P ma x) Current at P max (Imp ) Voltage at P max (V mp) Short-Circuit Current (I SC ) Open-Circuit Voltage (V OC ) Nominal Operating Temp.(T N OCT ) ll technical data at STC:1000W/m

More information

Test Report. File No.: SHV01023/16 Test Report No.: Taizhou, Zhejiang , P.R. China

Test Report. File No.: SHV01023/16 Test Report No.: Taizhou, Zhejiang , P.R. China Applicant... : Manufacturer... : Order No.... : Zhejiang ERA Solar Technology Co., Ltd. Sihai Road, Huangyan Economic Development Zone Taizhou, Zhejiang 318020, P.R. China Zhejiang ERA Solar Technology

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19630304.001 Bangalore, JULY 2015 Certificate No. T -1543 2 / 8 Contents CONTENTS... 2

More information

Large Area Steady State Solar Simulator - Apollo

Large Area Steady State Solar Simulator - Apollo AllReal APOLLO series steady-state solar simulator are AAA class which is the highest class on the world. AllReal APOLLO solar simulators designed with specific optical technology by tandem Xenon lamps,

More information

FSEC APPROVAL # XL15-NT

FSEC APPROVAL # XL15-NT AC GEC 4 IN SERIES TO UTILITY METER IN SERIES F-2 35A SW 60A SOLAR MODULE POWER BOX PM-25 270W 2 3 4 JUNCTION BOX 2 7 INVERTER I 6,000W 5 6 3 TO MAIN SERVICE ENTRANCE RE F. MODULES FSEC APPROVAL # XL5-NT90-02

More information

Colour your life! BISOL Spectrum Series. www. bisol. com

Colour your life! BISOL Spectrum Series. www. bisol. com Colour your life! BISOL Spectrum Series www. bisol. com BISOL Spectrum Series With respect for our natural surrounding and the architectural legacy in mind, we are introducing an exclusive BISOL Spectrum

More information

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China Applicant... : Manufacturer... : Order No.... : Zhejiang ERA Solar Technology Co., Ltd. Sihai Road, Huangyan Economic Development Zone, Taizhou, Zhejiang 318020, P.R. China Zhejiang ERA Solar Technology

More information

Dr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece

Dr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece Innovation Week on PV Systems Engineering and the other Renewable Energy Systems. 1-10 July 2013, Patras, Greece Dr E. Kaplani ekaplani@teipat.gr Mechanical Engineering Dept. T.E.I. of Patras, Greece R.E.S.

More information

Laboratory 2: PV Module Current-Voltage Measurements

Laboratory 2: PV Module Current-Voltage Measurements Laboratory 2: PV Module Current-Voltage Measurements Introduction and Background The current-voltage (I-V) characteristic is the basic descriptor of photovoltaic device performance. A fundamental understanding

More information

LIMITED WARRANTY AND SPECIFICATIONS. Kaneka Corporation (G-SA060)

LIMITED WARRANTY AND SPECIFICATIONS. Kaneka Corporation (G-SA060) LIMITED WARRANTY AND SPECIFICATIONS Between and Kaneka Corporation For Kaneka Thin film PV Modules (G-SA060) KANEKA CORPORATION OVERSEAS MARKETING SOLAR ENERGY DIVISION 3-2-4, NAKANOSHIMA,KITA-KU OSAKA

More information

Marking label of DelSolar module type D6M240B3A

Marking label of DelSolar module type D6M240B3A age 2 of 19 Report Ref. No. 61.410.11.029.01 Summary of testing: Tests performed (name of test and test clause): Testing location: Clause 6, Initial measurements: - Visual inspection - Maximum power determination

More information

TUV Listed LED Flood Lights. LED DRIVER inside LM-80 LED DRIVER LED FLOODLIGHTS

TUV Listed LED Flood Lights. LED DRIVER inside LM-80 LED DRIVER LED FLOODLIGHTS ED Flood ights ED DRIVER inside M-80 ED DRIVER ED FOODIGHTS ED FOOD IGHTS PRODUCT CATAOG Overview The ENETEC TUV isted ED floodlights are using UMIEDS UXEON 00 D luminous source, providing excellent lumen

More information

TEST REPORT Ammonia Resistance Testing of Photovoltaic (PV) Modules - Design Qualification and Type Approval

TEST REPORT Ammonia Resistance Testing of Photovoltaic (PV) Modules - Design Qualification and Type Approval Test Report issued under the responsibility of: TEST REPORT Ammonia Resistance Testing of Photovoltaic (PV) Modules - Design Qualification and Type Approval Report Reference No.... : 924214-3972-0001/157051

More information

Dongfang Electric Group Dongqi Investment&Development Co.,Ltd.

Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. Documents for TUV Certification ADDRESS: 666 West Jinshajiang Road,Deyang City,Sichuan Province, P.R.China 61201 2010-09-05 Catalogue 01 General

More information

R&S RSC Step Attenuator Specifications

R&S RSC Step Attenuator Specifications R&S RSC Step Attenuator Specifications Data Sheet Version 05.00 CONTENTS Definitions... 3 Specifications... 4 Step attenuator, 139 db, 1 db steps, DC to 6 GHz (models.03 and.13)... 4 Step attenuator, 139.9

More information

Page 1 of 19 Report Ref. No.: TEST REPORT IEC 62716:2013

Page 1 of 19 Report Ref. No.: TEST REPORT IEC 62716:2013 age 1 of 19 Report Ref. No.: 704061718718-00 TEST REORT IEC 62716:2013 TÜV SÜD Test report for photovoltaic (V) modules Ammonia corrosion testing Report reference No.... : 704061806701-00 Date of issue...

More information

Understanding Potential Induced Degradation for LG NeON Model

Understanding Potential Induced Degradation for LG NeON Model Understanding Potential Induced Degradation for LG NeON Model Table of Contents 2 CONTENTS 1. Introduction 3 2. PID Mechanism 4 3. LG NeON model PID Characterization 5 4. Description 7 6. Test Result 11

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

MAX. OUTPUT POWER 24/48/72/96/110 VDC 5 VDC 6 A 30 W 82% 0RQB-30Y05L. 0 R QB - 30 Y 05 L y. Output Power. Input Range

MAX. OUTPUT POWER 24/48/72/96/110 VDC 5 VDC 6 A 30 W 82% 0RQB-30Y05L. 0 R QB - 30 Y 05 L y. Output Power. Input Range The 0RQB-30Y05L is an isolated DC/DC converter providing 30 W of output power from a wide input range (24 V, 48 V, 72 V, 96 V, 110 V typical). Standard features include remote on/off, input under-voltage

More information

Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software

Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software Next PVA Webinar November 29, 10am PST http://www.solmetric.com/ webinar.html Paul Hernday Senior Applications Engineer paul@solmetric.com

More information

Traditional PWM vs Morningstar s TrakStar MPPT Technology

Traditional PWM vs Morningstar s TrakStar MPPT Technology Traditional PWM vs Morningstar s TrakStar MPPT Technology Morningstar s MPPT charge controllers use our patented TrakStar advanced control MPPT algorithm to harvest maximum power from a Solar Array s peak

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality Test Report Salt Mist corrosion Testing of Photovoltaic modules acc IEC 61701-2011 TÜV Report No: 19630874.001 Bangalore JULY 2016 Certificate No.

More information

Pag 1 of 15. Eurotest Laboratori S.r.l. Via Marconi, Brugine (PD) Italy

Pag 1 of 15. Eurotest Laboratori S.r.l. Via Marconi, Brugine (PD) Italy Pag 1 of 15 TEST REPORT IEC 82/685/NP (not ACCREDIA accredited) IEC 60068-2-78 IEC 61215 IEC 61730-2 System voltage durability test for crystalline silicon modules Design qualification and type approval

More information

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates 4th PV Performance Modelling and Monitoring Workshop 22nd and 23rd October, 2015 M. Schweiger TÜV Rheinland Energie

More information

Auftrags-Nr.: Order No.: Auftragsdatum: Order date:

Auftrags-Nr.: Order No.: Auftragsdatum: Order date: Prüfbericht-Nr.: 21290449.001 Auftrags-Nr.: Order No.: 21243643 Seite 1 von 10 Page 1 of 10 Kunden-Referenz-Nr.: Client Reference No.: 3201853 Auftragsdatum: Order date: 15 May 2018 Auftraggeber: Client:

More information

Rotating Anode X-ray Tube Assembly

Rotating Anode X-ray Tube Assembly RADII H18X H18Y Datasheet Rotating Anode X-ray Tube Assembly The tube unit is so constructed that an X-ray tube is sealed in a diagnostic type protective tube housing of electric shockproof, radiation

More information

EC centrifugal fan - RadiCal

EC centrifugal fan - RadiCal ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen Amtsgericht (court of registration)

More information

Electromotoric actuators for valves

Electromotoric actuators for valves ACVATIX TM Electromotoric actuators for valves SAT.. Electromotoric actuators with 5.5 mm stroke and 300 N positioning force SAT31.. Operating voltage AC 230 V, 3-position control signal Operating voltage

More information

New Tools for PV Array Commissioning and Troubleshooting

New Tools for PV Array Commissioning and Troubleshooting New Tools for PV Array Commissioning and Troubleshooting June 30, 2011 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 Bryan Bass Sales Engineer bryan@solmetric.com Solmetric Solutions

More information

New Tools for PV Array Commissioning and Troubleshooting

New Tools for PV Array Commissioning and Troubleshooting New Tools for PV Array Commissioning and Troubleshooting Solmetric PVA-600 Megger MIT430 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 April 5, 2012 Audio is available by telephone

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality Test Report Salt Mist corrosion Testing of Photovoltaic modules acc IEC 61701-2011 TÜV Report No: 19631432.001 Bangalore July 2017 2 / 19 Contents:

More information

HT-MM900A Military Temperature Oscillator

HT-MM900A Military Temperature Oscillator HT-MM900A Military Temperature Oscillator Features Performance Specifica ons Applications Frequency Range 1 MHz and 137 MHz accurate to 6 decimal places Military Applica ons Low power consump on of 4.5

More information

EM-CAN. Field-bus Stepper Drive. Leadshine Technology Co., Ltd. Website:

EM-CAN. Field-bus Stepper Drive. Leadshine Technology Co., Ltd. Website: Reliable Motion Control Products EM-CAN Field-bus Stepper Drive Leadshine Technology Co., Ltd. Website: www.leadshine.com Service: Tel: -7--77 (for Asia, Australia, Africa region) -7-- (for Europe region)

More information

TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING

TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING /ALLOWED SUBCONTACTING = equired by Lab S = May be subcontracted 10.1 Visual inspection

More information

Solmetric White Paper: Winning Contracts with PV Array Testing

Solmetric White Paper: Winning Contracts with PV Array Testing Solmetric White Paper: Winning Contracts with PV Array Testing Contents Introduction...1 Background: I-V Curves in Field Applications...2 What is an I-V curve?...2 Where has I-V curve tracing been used

More information

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector

ILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector Characteristics integrated drive ILA with servo motor - 24..48 V - EtherCAT - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network

More information

Solmetric PVA-600 PV Analyzer

Solmetric PVA-600 PV Analyzer Introducing the Solmetric PVA-600 PV Analyzer Paul Hernday PV Applications Engineer http://www.solmetric.com/pva600.html Bryan Bass Sales Engineer Topics Introduction to Solmetric Verifying PV array performance

More information

The European Commission s science and knowledge service

The European Commission s science and knowledge service The European Commission s science and knowledge service Joint Research Centre TEMPERATURE COEFFICIENTS OF N-TYPE BIFACIAL SILICON PV MODULES UNDER NATURAL AND SIMULATED SUNLIGHT Juan Lopez-Garcia, Diego

More information

Reference: Photovoltaic Systems, p

Reference: Photovoltaic Systems, p PV systems are comprised of building blocks of cells, modules and arrays to form a DC power generating unit with specified electrical output. Reference: Photovoltaic Systems, p. 115-118 Reference: Photovoltaic

More information

1.6W Gate Drive DC-DC Converter P2AGDC-Series

1.6W Gate Drive DC-DC Converter P2AGDC-Series SIL7 Package Single / dual output 3000 Vrms isolation -40...105 C operating temperature range Efficiency up to 80 % Low couple I/O capacitance Model guide Type designation Input voltage range [V DC ] min.

More information

Product Information PI

Product Information PI Product Information PI TOSHIBA X-RAY TUBE D-045 Stationary Anode X-ray Tube Especially designed for dental radiography unit. This tube has focus 0.4, and is available for maximum tube voltage 70 kv. Installed

More information

Supplemental Calculation Sheets for Inverter #2

Supplemental Calculation Sheets for Inverter #2 Solar PV Standard Plan Simplified Central/String Inverter Systems for One and TwoFamily Dwellings (10 KW or Less) Supplemental Calculation Sheets for Inverter #2 FORM PV 3S DC Information: Module Manufacturer:

More information

Series P. Applications

Series P. Applications Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any

More information

Array. Source-circuit configuration is arguably the most

Array. Source-circuit configuration is arguably the most Array Source-circuit configuration is arguably the most important aspect of PV system design. The electrical and mechanical characteristics of a PV array follow from this fundamental design decision, which

More information

1) Solar simulator with I-V measurement setup and software

1) Solar simulator with I-V measurement setup and software Department of Optoelectronics, University of Kerala, Kariavattom, Thiruvananthapuram, Kerala, India 695581, Ph: 91 471 2308167 OPTO/Nanophotonics-Phase II/P-1/2014-15 Quotation Notice Quotations are invited

More information

For more information, please visit the product page If your application requires forced air, view our Dc Fans. output. output current max (ma)

For more information, please visit the product page If your application requires forced air, view our Dc Fans. output. output current max (ma) date 12/08/2017 page 1 of 10 SERIES: PBO-1 DESCRIPTION: AC-DC POWER SUPPLY FEATURES up to 1 W continuous power ultra-compact SIP package available in straight-pin and bent-pin configurations wide input

More information

Engineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin

Engineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin Simulation of the effects of global irradiance, ambient temperature and partial shading on the output of the photovoltaic module using MATLAB/Simulink and ICAP/4 A report submitted to the School of Engineering

More information

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications.

LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications. LDC480 Series is a single phase, extremely compact Power Supply with active PFC specially designed for space sensitive and demanding applications. Its compact size, high efficiency, excellent reliability

More information

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description. Electronic monitoring relay for voltage monitoring in three-phase networks INTERFACE Data sheet 102110_en_03 1 Description PHOENIX CONTACT - 09/2009 Features Increasingly higher demands are being placed

More information

Switching Power Supply Type SPP1 60W Enclosed type

Switching Power Supply Type SPP1 60W Enclosed type Type SPP1 60W Enclosed type Universal AC input full range Short circuit protection Internal input filter High efficiency High average efficiency (meets ErP) Low stand-by power consumption CE, TUV, and

More information

Australian Journal of Basic and Applied Sciences. Evaluation of Diode Model Parameters for a Solar Panel Simulation

Australian Journal of Basic and Applied Sciences. Evaluation of Diode Model Parameters for a Solar Panel Simulation ISSN:1991-8178 Australian Journal of Basic and Applied Sciences Journal home page: www.ajbasweb.com Evaluation of Diode Model Parameters for a Solar Panel Simulation 1 Thangavel Bhuvaneswari, 2 Venkatasessiah

More information

SILICon IrrADIAnCe SenSor

SILICon IrrADIAnCe SenSor Measurement of Solar Silicon irradiance sensors (Si sensor) show a cost-effective, but rugged and reliable solution for the measurement of solar irradiance, especially for the monitoring of Photovoltaic

More information

Modelling and simulation of PV module for different irradiation levels Balachander. K Department of EEE, Karpagam University, Coimbatore.

Modelling and simulation of PV module for different irradiation levels Balachander. K Department of EEE, Karpagam University, Coimbatore. 6798 Available online at www.elixirpublishers.com (Elixir International Journal) Electrical Engineering Elixir Elec. Engg. 43 (2012) 6798-6802 Modelling and simulation of PV module for different irradiation

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

EC centrifugal fan. forward curved, dual inlet with housing (flange)

EC centrifugal fan. forward curved, dual inlet with housing (flange) D3G46-AH- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 2 D-74673 Mulfingen Phone +49 7938 8- Fax +49 7938 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court

More information

Proprietary Calibration Certificate

Proprietary Calibration Certificate Calibration Mark: 1003196SBR0813 1/6 Proprietary Calibration Certificate Object: thin film solar cell Manufacturer: Solibro Serial number: 130618-3A Internal serial number: SBR003 Calibration mark: 1003196SBR0813

More information

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR Building Division 1855 Placer Street, Suite 102 Redding, California 96001 Phone: (530) 225-5761 Fax: (530) 245-6468 Inspection Request Line: (530) 244-5068 Web:

More information

Networking Computers and Peripherals Telecommunications

Networking Computers and Peripherals Telecommunications The 0RCY-60U12x is part of the isolated DC/DC converters that operate from a wide input range (18 VDC - 75 VDC) and can cover both 24 Vin and 48 Vin input range. These units will provide up to 84 W of

More information

20KW Transient Voltage Suppressor 20KPA20A 20KPA300CA. 20KW Transient Voltage Suppressor. Features. Mechanical Data

20KW Transient Voltage Suppressor 20KPA20A 20KPA300CA. 20KW Transient Voltage Suppressor. Features. Mechanical Data Features Glass passivated junction 20KW peak pulse power capability at 10/1000μs waveform repetition rate (duty cycles): 0.01% Fast response time: typically less than 1.0ps from 0v to VBR min. Excellent

More information

Efficiency higher than 85% Power Factor >95% Case TC* Protec on

Efficiency higher than 85% Power Factor >95% Case TC* Protec on LED Driver - DS Series 50W DC Class 2 Supply DS50W Aluminum Case Series 100-277V FEATURES UL8750, EN61347, UL1310, UL48, cul, CE, TUV, KAMA, CQC compliant FCC Part 15/18 Class B and EN55015 compliant Meet

More information

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is

More information

Small Signal Zener Diodes

Small Signal Zener Diodes Small Signal Zener Diodes FEATURES Zener voltage specified at 5 μa Maximum delta V Z given from μa to μa Very high stability Low noise AEC-Q qualified Material categorization: For definitions of compliance

More information

VITO LT. Global Experience. Locally Applied. A dependable choice.

VITO LT. Global Experience. Locally Applied. A dependable choice. VITO LT A dependable choice. your accuracy requirements for tank inventory. Global Experience. Locally Applied. The VITO LT probe belongs to the VITO family for temperature and water bottom measurement.

More information

ArcLine Optic (Colour)

ArcLine Optic (Colour) ArcLine Optic (Colour) Category: ArcLine Optic Client: Project: Specifi er: Type: Qty: IP2X 1.9 (48) 0.9 (22) FEATURES: Input Voltage: 48V DC Via ArcPower Range Power consumption: 6.8W, 13,6W, 20.4W, 27.2W,

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS FEATURES AND BENEFITS* Up to 1,000,000 duty cycles or 10 year DC life 51V DC working voltage Active cell balancing Temperature output Overvoltage outputs available High power density Extreme Vibration

More information

Liquid level monitoring relay CM-ENS.2x

Liquid level monitoring relay CM-ENS.2x Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry

More information

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator Specifications General Input Channels One Input Types Digital (S 3 L) Serial ASCII, TTL level, 9600 bps Frequency Range 0.5 to 1500 Hz Accuracy 0.5% of reading Measurement Types Flow, ph/orp, Conductivity/Resis

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

Operating Light marled V16 / V16 D

Operating Light marled V16 / V16 D marled V16 / V16 D Mechanical Design Operating light system for ceiling installation, consisting of ceiling tube, horizontal cantilevers, spring arms, cardan joint and light bodies. Depending on the situation

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

Committee E44 on Solar, Geothermal and Other Alternative Energy Sources

Committee E44 on Solar, Geothermal and Other Alternative Energy Sources Committee E44 on Solar, Geothermal and Other Alternative Energy Sources Formed in 1978 Meets once a year during November Committee Week Current membership of approximately 70 Jurisdiction over 49 standards

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

The 0RQB-C5U54x is an isolated DC-DC converter that operates from a nominal 24 VDC, 48 VDC source.

The 0RQB-C5U54x is an isolated DC-DC converter that operates from a nominal 24 VDC, 48 VDC source. The 0RQB-C5U54x is an isolated DC-DC converter that operates from a nominal 24 VDC, 48 VDC source. This unit will provide up to 162 W of output power from a nominal 24 VDC, 48 VDC input. This unit is designed

More information

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force 4 584 ACVATIX Electromotoric actuators for valves SAT.. with a 5.5 mm stroke and 300 N positioning force SAT31.. Operating voltage AC 230 V, 3-position control signal SAT61.. Operating voltage AC/DC 24

More information

PERFORMANCE EVALUATION OF POLYCRYSTALLINE SOLAR PHOTOVOLTAIC MODULE IN WEATHER CONDITIONS OF MAIDUGURI, NIGERIA

PERFORMANCE EVALUATION OF POLYCRYSTALLINE SOLAR PHOTOVOLTAIC MODULE IN WEATHER CONDITIONS OF MAIDUGURI, NIGERIA Arid Zone Journal of Engineering, Technology and Environment. August, 2013; Vol. 9, 69-81 PERFORMANCE EVALUATION OF POLYCRYSTALLINE SOLAR PHOTOVOLTAIC MODULE IN WEATHER CONDITIONS OF MAIDUGURI, NIGERIA

More information

SMAJ5.0~440(C)A MAXIMUM RATINGS AND CHARACTERISTICS THERMAL CONSIDERATIONS. Transient Voltage Suppressors DO-214AC(SMA) PACKAGE SCHEMATIC SYMBOL

SMAJ5.0~440(C)A MAXIMUM RATINGS AND CHARACTERISTICS THERMAL CONSIDERATIONS. Transient Voltage Suppressors DO-214AC(SMA) PACKAGE SCHEMATIC SYMBOL Transient Suppressors DESCRIPTION The SMAJ series is designed specifically to protect sensi ve electronic equipment from voltage transients induced by lightning and other transient voltage events. FEATURES

More information

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Installation Instructions P/N MMI-20011709, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Note: For hazardous installations in Europe, refer to standard EN

More information

Signet 9900 Transmitter

Signet 9900 Transmitter Signet 9900 Transmitter Member of the SmartPro Family of Instruments Features Field Mount Multi-Parameter input selection Large auto-sensing backlit display with at a glance visibility Dial-type digital

More information

INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES

INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES - Page 1/13. Appendix II - CONTENT 1. INTRODUCTION...3 2. TECHNICAL DATA...3 3. PROTECTION DIODES...6 4.

More information