Dongfang Electric Group Dongqi Investment&Development Co.,Ltd.

Size: px
Start display at page:

Download "Dongfang Electric Group Dongqi Investment&Development Co.,Ltd."

Transcription

1 Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. Documents for TUV Certification ADDRESS: 666 West Jinshajiang Road,Deyang City,Sichuan Province, P.R.China

2 Catalogue 01 General information 02 Declaration of conformity 03 Declaration of precondition 04 Schematic electrical connection of cells and strings 05 Dimensions of PV modules 06 Cell and distance without frame drawing 07 Critical component list 0 Data sheet for all module types of family 09 Marking label 10 User manual 11 Annex

3 General Information 1. Applicant: Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. Address: 666 West Jinshajiang Road,Deyang City,Sichuan Province,P.R. China Manufacturer/Factory1: Dongfang Electric (Jiuquan) Solar Power Engineering Technology Co., Ltd. Address: Western Section, High-tech Zone, Jiuquan, Gansu Province Manufacturer/Factory 2 : Dongfang Electric (Yixing) Magi Solar Technology Co.,Ltd. Address:Wenzhuang Rd.6,yixing Jiangsu ,china 3. Type Designation Series: DQPVM240M5-96Series:DQPVM220M5-96,DQPVM225M5-96,DQPVM230M5-96, DQPVM235M5-96,DQPVM240M5-96,DQPVM245M5-96, DQPVM250M5-96,DQPVM255M5-96, DQPVM260M5-96 DQPVM15M5-72Series:DQPVM170M5-72,DQPVM175M5-72,DQPVM10M5-72, DQPVM15M5-72,DQPVM190M5-72,DQPVM195M5-72, DQPVM200M5-72 DQPVM90M5-36Series: DQPVM5M5-36,DQPVM90M5-36,DQPVM95M5-36 DQPVM275P6-72Series: DQPVM250P6-72,DQPVM255P6-72,DQPVM260P6-72, DQPVM265P6-72,DQPVM270P6-72,DQPVM275P6-72, DQPVM20P6-72,DQPVM25P6-72,DQPVM290P6-72, DQPVM295P6-72,DQPVM300P6-72 DQPVM230P6-60Series:DQPVM210P6-60,DQPVM215P6-60,DQPVM220P6-60, DQPVM225P6-60,DQPVM230P6-60,DQPVM235P6-60, DQPVM240P6-60,DQPVM245P6-60, DQPVM250P6-60 DQPVM210P6-54Series:DQPVM190P6-54,DQPVM195P6-54,DQPVM200P6-54, DQPVM205P6-54,DQPVM210P6-54,DQPVM215P6-54, DQPVM220P6-54, DQPVM225P6-54,DQPVM230P6-54 DQPVM20M6-72Series:DQPVM255M6-72,DQPVM260M6-72,DQPVM265M6-72, DQPVM270M6-72,DQPVM275M6-72,DQPVM20M6-72,

4 DQPVM25M6-72,DQPVM290M6-72,DQPVM295M6-72, DQPVM300M6-72,DQPVM305M6-72 DQPVM230M6-60Series:DQPVM210M6-60,DQPVM215M6-60,DQPVM220M6-60, DQPVM225M6-60,DQPVM230M6-60,DQPVM235M6-60, DQPVM240M6-60,DQPVM245M6-60, DQPVM250M6-60 DQPVM210M6-54Series:DQPVM190M6-54,DQPVM195M6-54,DQPVM200M6-54, DQPVM205M6-54,DQPVM210M6-54,DQPVM215M6-54, DQPVM220M6-54,DQPVM225M6-54, DQPVM230M Contact Person: Mr.Lei Kai ( 雷凯 ) Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. 666 West Jinshajiang Road,Deyang City,Sichuan Province,P.R.China TEL: FAX: leikai@mail.dfstw.com.

5 Declaration of Conformity We (Dongfang Electric Group Dongqi Investment&Development Co.,Ltd.) declare that test samples ( DQPVM240M5-96, DQPVM15M5-72, DQPVM90M5-36, DQPVM275P6-72, DQPVM230P6-60, DQPVM210P6-54, DQPVM20M6-72, DQPVM230M6-60,DQPVM210M6-54) are built with identical materials, components and production parameters as the modules of the type family also covered by the certificate but not tested(dqpvm220m5-96,dqpvm225m5-96,dqpvm230m5-96,dqpvm235m5-96, DQPVM245M5-96,DQPVM250M5-96,DQPVM255M5-96,DQPVM260M5-96; DQPVM170M5-72,DQPVM175M5-72,DQPVM10M5-72,DQPVM190M5-72, DQPVM195M5-72,DQPVM200M5-72; DQPVM5M5-36, DQPVM95M5-36; DQPVM250P6-72,DQPVM255P6-72,DQPVM260P6-72,DQPVM265P6-72, DQPVM270P6-72,DQPVM20P6-72,DQPVM25P6-72,DQPVM290P6-72, DQPVM295P6-72,DQPVM300P6-72; DQPVM210P6-60,DQPVM215P6-60,DQPVM220P6-60,DQPVM225P6-60, DQPVM235P6-60, DQPVM240P6-60, DQPVM245P6-60,DQPVM250P6-60; DQPVM190P6-54,DQPVM195P6-54,DQPVM200P6-54,DQPVM205P6-54, DQPVM215P6-54, DQPVM220P6-54,DQPVM225P6-54,DQPVM230P6-54; DQPVM255M6-72,DQPVM260M6-72,DQPVM265M6-72,DQPVM270M6-72, DQPVM275M6-72,DQPVM25M6-72,DQPVM290M6-72,DQPVM295M6-72, DQPVM300M6-72, DQPVM305M6-72; DQPVM210M6-60,DQPVM215M6-60,DQPVM220M6-60,DQPVM225M6-60, DQPVM235M6-60, DQPVM240M6-60,DQPVM245M6-60, DQPVM250M6-60; DQPVM190M6-54,DQPVM195M6-54,DQPVM200M6-54,DQPVM205M6-54, DQPVM215M6-54,DQPVM220M6-54,DQPVM225M6-54, DQPVM230M6-54. Dongfang Electric Group Dongqi Investment&Development Co.,Ltd

6 Declaration of Precondition We (Dongfang Electric Group Dongqi Investment&Development Co.,Ltd.) declare that all test samples have already been preconditioned with an irradiation dose of 5-5.5kWh/m 2 in open circuit conditions. Dongfang Electric Group Dongqi Investment&Development Co.,Ltd

7 Schematic electrical connection of cells and strings DQPVM240M5-96 Series: Connector Diode Cells DQPVM15M5-72 Series: Connector Diode Cells

8 DQPVM90M5-36 Series: Connector Diode Cells DQPVM275P6-72 / DQPVM20M6-72Series: Connector Diode Cells

9 DQPVM230P6-60 / DQPVM230M6-60 Series: Connector Diode Cells DQPVM210P6-54/ DQPVM210M6-54 Series: Connector Diode Cells

10 条形码 4mm2 PV Junction Box 2 Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. Structure with identification of each sheets thickness (incl. solar cell thickness) Glass 3.2mm Mono-Si Cell 0.19±0.02mm Poly-Si Cell 0.20±0.03mm EVA 0.5mm EVA 0.5mm TPT 0.32mm Dimensions of PV Module (Unit: mm) DQPVM240M5-96 Series: 1065±1 50±1 60± ±1 Ⅱ 9 Junction Box Label 标签 Mounting holes I I ± φ4 Grounding holes 10± negative ( - ) positive ( + ) II Connector 1015±1 A A Section A-A

11 条形码 序列号 4mm2 PV Junction Box 2 2 Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. DQPVM15M5-72 Series: 0±1 45±1 (404) 60±1 Ⅱ Junction Box 标签 Label Mounting holes I I ± φ4 Grounding holes 10±0.5 00±1 1300± negative ( - ) positive ( + ) II Connector A A 45 75±1 35 Section A-A DQPVM90M5-36 Series: 553±1 35± ±1 II 9 60±1 6 Junction Box 标签 65 I 14 Label I ±1 2-? 4 negative ( - ) 10±0.5 positive ( + ) 00± Connector II 503±1 35 A A 35 Section A-A

12 条形码 条形码 4mm2 PV Junction Box 4mm2 PV Junction Box 2 Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. DQPVM275P6-72 Series: 992±1 50±1 60±1 496±1 Ⅱ 6 9 Junction Box Label 标签 100 Mounting holes I 14 I ±1 2-φ4 Grounding holes negative ( - ) positive ( + ) 10±0.5 00±1 1300± Connector II 942±1 50 A 35 Section A-A DQPVM230P6-60 Series: 992±1 50±1 60±1 496±1 Ⅱ 6 9 Junction Box 标签 Label Mounting holes I 7.5 I ±1 2-φ4 Grounding holes 10±0.5 00±1 1300± negative ( - ) positive ( + ) II Connector A A ±1 35 Section A-A

13 条形码 条形码 P654m m2 PV Juncti on Box 4mm2 PV Junction Box 2 2 Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. DQPVM210P6-54 Series: 992±1 50±1 60±1 496±1 Ⅱ 6 9 Junction Box Label 标签 I I Mounting holes ±1 2-φ4 Grounding holes 10±0.5 30±1 100± negative ( - ) positive ( + ) II Connector 50 A A 942±1 35 Section A-A DQPVM20M6-72 Series: 992±1 50±1 496±1 60±1 Ⅱ 6 9 R4.5 Junction Box 标签 100 II 14 Label Mounting holes I ±1 2-φ4 Grounding holes negative ( - ) positive ( + ) 10±0.5 00±1 1300± Connector II 942±1 50 A 35 Section A-A

14 条形码 条形码 P654mm2 PV Junction Box 2 2 Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. DQPVM230M6-60 Series: 992±1 50±1 60±1 496±1 Ⅱ 6 9 R4.5 Junction Box 100 Label 标签 Mounting holes I 7.5 I ±1 2-φ4 Grounding holes 10±0.5 00±1 1300± negative ( - ) Connector positive ( + ) II A A ±1 35 Section A-A DQPVM210M6-54 Series: 992±1 50±1 496±1 II 9 R4.5 60± Junction Box 100 ILabel 标签 I I Mounting holes ±1 2-φ4 Grounding holes 10±0.5 30±1 100± negative ( - ) positive ( + ) II Connector A A 942± Section A-A

15 Cell and edge distances DQPVM240M5-96 Series: 26±1 1574±1 9±1 1.5±1 条形码 14±1 3±1 3±1 35±1 75±1 3±1 105±1 1.5±1 2±0.5 26±1 DQPVM15M5-72 Series: 26±1 1574±1 1.5±1 3±1 3±1 02±1 3±1 1.5±1 15±1 55±1 2±0.5 26±1

16 DQPVM90M5-36 Series: 26±1 1193±1 3±1 5±1 序列号 3±1 1.5±1 1.5±1 15±1 55±1 546±1 3±1 2±0.5 26±1 DQPVM275P6-72 Series: 2±1 1950±1 条形码 5±1 3±1 21±1 75±1 95±1 17±1 17±1 5±1 2±0.5 2±1

17 DQPVM230P6-60 Series: 32.5±1 1643±1 条形码 21±1 75±1 17±1 17±1 5±1 3±1 5±1 95±1 2± ±1 DQPVM210P6-54 Series: 17±1 1475±1 27.5±1 27.5±1 5±1 条形码 5± ±1 21±1 75±1 3±1 95±1 2± ±1

18 DQPVM20M6-72 Series: 17±1 2±1 1950±1 条形码 5±1 17±1 3±1 21±1 75±1 95±1 5±1 2±0.5 2±1 DQPVM230M6-60 Series: 32.5±1 1643±1 条形码 17±1 95±1 17±1 5±1 3±1 21±1 75±1 5±1 2± ±1

19 DQPVM210M6-54 Series: 27.5±1 1475±1 条形码 21±1 75±1 17±1 17±1 5±1 5±1 3±1 95±1 2± ±1

20 Technimcal specification and data sheets of the used components/materials DQPVM240M5-96 Series: Items Components/objects Type or spec Quantity Manufacturer 1 Cells mm 96 2 Soldering strip mm 20 3 Internal bus 0.2 6mm 14 DONGFANG ELECTRIC (YIXING) MAGI SOLAR POWER TECHNOLOGY CO.,LTD. Shanghai SunBy Solar Technology Co., Ltd. Shanghai SunBy Solar Technology Co., Ltd. 4 Glass mm 1 Tianjin Seedglass Co., Ltd. 5 Back sheet mm 1 FILMCUTTER 6 EVA S11, mm 2 Bridgestone Corporation 7 Junction box PV- ZH00 1 Ningbo Zhonghuan Electrical Technology Co., Ltd. Bypass diode 10SQ050 4 Pan Jit International Inc 9 Cable PV1-F,1 4mm 2,L=900mm 2 Wuxi Xinhongye Wire & Cable Co., Ltd. 10 Connector PV- ZH202 1set Ningbo Zhonghuan Electrical Technology Co., Ltd. 11 Al frame Anodized Aluminum frame 6063 T5, 2 Jiangyin haida mm 12 Al frame Anodized Aluminum frame 6063 T5, 2 Jiangyin haida mm 13 Al Corner bonder mm 4 Jiangyin haida 14 Isolation with Back sheet mm 1 FILMCUTTER 15 Isolation with EVA S11, mm 1 Bridgestone Corporation 16 adhesive Guibao 300ml Chengdu Guibao Science and Technology Co., Ltd.

21 DQPVM 15M5-72 Series: Items Components/objects Type or spec Quantity Manufacturer 1 Cells mm 72 2 Soldering strip mm Internal bus 0.2 5mm 11 DONGFANG ELECTRIC (YIXING) MAGI SOLAR POWER TECHNOLOGY CO.,LTD. Shanghai SunBy Solar Technology Co., Ltd. Shanghai SunBy Solar Technology Co., Ltd. 4 Glass mm 1 Tianjin Seedglass Co., Ltd. 5 Back sheet mm 1 FILMCUTTER 6 EVA S11, mm 2 Bridgestone Corporation 7 Junction box PV-ZH00 1 Ningbo Zhonghuan Electrical Technology Co., Ltd. Bypass diode 10SQ050 3 Pan Jit International Inc 9 Cable PV1-F,1 4mm 2,L=900mm 2 Wuxi Xinhongye Wire & Cable Co., Ltd. 10 Connector PV-ZH202 1set Ningbo Zhonghuan Electrical Technology Co., Ltd. 11 Al frame 12 Al frame Anodized Aluminum frame 6063 T5, mm Anodized Aluminum frame 6063 T5, mm 2 Jiangyin haida 2 Jiangyin haida 13 Al Corner bonder mm 4 Jiangyin haida 14 Isolation with Back sheet mm 1 FILMCUTTER 15 Isolation with EVA S11, mm 1 Bridgestone Corporation 16 adhesive Guibao 225ml Chengdu Guibao Science and Technology Co., Ltd.

22 DQPVM 90M5-36 Series: Items Components/objects Type or spec Quantity Manufacturer 1 Cells mm 36 2 Soldering strip mm 0 3 Internal bus 0.2 5mm DONGFANG ELECTRIC (YIXING) MAGI SOLAR POWER TECHNOLOGY CO.,LTD. Shanghai SunBy Solar Technology Co., Ltd. Shanghai SunBy Solar Technology Co., Ltd. 4 Glass mm 1 Tianjin Seedglass Co., Ltd. 5 Back sheet mm 1 FILMCUTTER 6 EVA S11, mm 2 Bridgestone Corporation 7 Junction box PV-ZH00 1 Ningbo Zhonghuan Electrical Technology Co., Ltd. Bypass diode 10SQ050 3 Pan Jit International Inc 9 Cable PV1-F,1 4mm 2,L=900mm 2 Wuxi Xinhongye Wire & Cable Co., Ltd. 10 Connector PV-ZH202 1set Ningbo Zhonghuan Electrical Technology Co., Ltd. 11 Al frame 12 Al frame Anodized Aluminum frame 6063 T5, mm Anodized Aluminum frame 6063 T5, mm 2 Jiangyin haida 2 Jiangyin haida 13 Al Corner bonder mm 4 Jiangyin haida 14 Isolation with Back sheet mm 1 FILMCUTTER 15 Isolation with EVA S11, mm 1 Bridgestone Corporation 16 adhesive Guibao 110ml Chengdu Guibao Science and Technology Co., Ltd.

23 DQPVM 275P6-72 Series: Items Components/objects Type or spec Quantity Manufacturer 1 Cells mm 72 2 Soldering strip 0.1 2mm Internal bus 0.2 6mm 11 DONGFANG ELECTRIC (YIXING) MAGI SOLAR POWER TECHNOLOGY CO.,LTD. Shanghai SunBy Solar Technology Co., Ltd. Shanghai SunBy Solar Technology Co., Ltd. 4 Glass mm 1 Tianjin Seedglass Co., Ltd. 5 Back sheet mm 1 FILMCUTTER 6 EVA S11, mm 2 Bridgestone Corporation 7 Junction box PV-ZH010 1 Ningbo Zhonghuan Electrical Technology Co., Ltd. Bypass diode 10SQ050 6 Pan Jit International Inc 9 Cable PV1-F,1 4mm 2,L=900mm 2 Wuxi Xinhongye Wire & Cable Co., Ltd. 10 Connector PV-ZH202 1set Ningbo Zhonghuan Electrical Technology Co., Ltd. 11 Al frame 12 Al frame Anodized Aluminum frame 6063 T5, mm Anodized Aluminum frame 6063 T5, mm 2 Jiangyin haida 2 Jiangyin haida 13 Al Corner bonder mm 4 Jiangyin haida 14 Isolation with Back sheet mm 1 FILMCUTTER 15 Isolation with EVA S11, mm 1 Bridgestone Corporation 16 adhesive Guibao 300ml Chengdu Guibao Science and Technology Co., Ltd.

24 DQPVM 230P6-60 Series: Items Components/objects Type or spec Quantity Manufacturer 1 Cells mm 60 2 Soldering strip 0.1 2mm Internal bus 0.2 6mm 11 DONGFANG ELECTRIC (YIXING) MAGI SOLAR POWER TECHNOLOGY CO.,LTD. Shanghai SunBy Solar Technology Co., Ltd. Shanghai SunBy Solar Technology Co., Ltd. 4 Glass mm 1 Tianjin Seedglass Co., Ltd. 5 Back sheet mm 1 FILMCUTTER 6 EVA S11, mm 2 Bridgestone Corporation 7 Junction box PV-ZH010 1 Ningbo Zhonghuan Electrical Technology Co., Ltd. Bypass diode 10SQ050 6 Pan Jit International Inc 9 Cable PV1-F,1 4mm 2,L=900mm 2 Wuxi Xinhongye Wire & Cable Co., Ltd. 10 Connector PV-ZH202 1set Ningbo Zhonghuan Electrical Technology Co., Ltd. 11 Al frame 12 Al frame Anodized Aluminum frame 6063 T5, mm Anodized Aluminum frame 6063 T5, mm 2 Jiangyin haida 2 Jiangyin haida 13 Al Corner bonder mm 4 Jiangyin haida 14 Isolation with Back sheet mm 1 FILMCUTTER 15 Isolation with EVA S11, mm 1 Bridgestone Corporation 16 adhesive Guibao 255ml Chengdu Guibao Science and Technology Co., Ltd.

25 DQPVM 210P6-54 Series: Items Components/objects Type or spec Quantity Manufacturer 1 Cells mm 54 2 Soldering strip 0.1 2mm Internal bus 0.2 6mm 11 DONGFANG ELECTRIC (YIXING) MAGI SOLAR POWER TECHNOLOGY CO.,LTD. Shanghai SunBy Solar Technology Co., Ltd. Shanghai SunBy Solar Technology Co., Ltd. 4 Glass mm 1 Tianjin Seedglass Co., Ltd. 5 Back sheet mm 1 KREMPEL GROUP 6 EVA S11, mm 2 Bridgestone Corporation 7 Junction box PV-ZH010 1 Ningbo Zhonghuan Electrical Technology Co., Ltd. Bypass diode 10SQ050 6 Pan Jit International Inc 9 Cable PV1-F,1 4mm 2,L=900mm 2 Wuxi Xinhongye Wire & Cable Co., Ltd. 10 Connector PV-ZH202 1set Ningbo Zhonghuan Electrical Technology Co., Ltd. 11 Al frame 12 Al frame Anodized Aluminum frame 6063 T5, mm Anodized Aluminum frame 6063 T5, mm 2 Jiangyin haida 2 Jiangyin haida 13 Al Corner bonder mm 4 Jiangyin haida 14 Isolation with Back sheet mm 1 FILMCUTTER 15 Isolation with EVA S11, mm 1 Bridgestone Corporation 16 adhesive Guibao 210ml Chengdu Guibao Science and Technology Co., Ltd.

26 DQPVM 20M6-72 Series: Items Components/objects Type or spec Quantity Manufacturer 1 Cells mm 72 2 Soldering strip 0.1 2mm Internal bus 0.2 6mm 11 DONGFANG ELECTRIC (YIXING) MAGI SOLAR POWER TECHNOLOGY CO.,LTD. Shanghai SunBy Solar Technology Co., Ltd. Shanghai SunBy Solar Technology Co., Ltd. 4 Glass mm 1 Tianjin Seedglass Co., Ltd. 5 Back sheet mm 1 FILMCUTTER 6 EVA S11, mm 2 Bridgestone Corporation 7 Junction box PV-ZH010 1 Ningbo Zhonghuan Electrical Technology Co., Ltd. Bypass diode 10SQ050 6 Pan Jit International Inc 9 Cable PV1-F,1 4mm 2,L=900mm 2 Wuxi Xinhongye Wire & Cable Co., Ltd. 10 Connector PV-ZH202 1set Ningbo Zhonghuan Electrical Technology Co., Ltd. 11 Al frame 12 Al frame Anodized Aluminum frame 6063 T5, mm Anodized Aluminum frame 6063 T5, mm 2 Jiangyin haida 2 Jiangyin haida 13 Al Corner bonder mm 4 Jiangyin haida 14 Isolation with Back sheet mm 1 FILMCUTTER 15 Isolation with EVA S11, mm 1 Bridgestone Corporation 16 adhesive Guibao 300ml Chengdu Guibao Science and Technology Co., Ltd.

27 DQPVM 230M6-60 Series: Items Components/objects Type or spec Quantity Manufacturer 1 Cells mm 60 2 Soldering strip 0.1 2mm Internal bus 0.2 6mm 11 DONGFANG ELECTRIC (YIXING) MAGI SOLAR POWER TECHNOLOGY CO.,LTD. Shanghai SunBy Solar Technology Co., Ltd. Shanghai SunBy Solar Technology Co., Ltd. 4 Glass mm 1 Tianjin Seedglass Co., Ltd. 5 Back sheet mm 1 FILMCUTTER 6 EVA S11, mm 2 Bridgestone Corporation 7 Junction box PV-ZH010 1 Ningbo Zhonghuan Electrical Technology Co., Ltd. Bypass diode 10SQ050 6 Pan Jit International Inc 9 Cable PV1-F,1 4mm 2,L=900mm 2 10 Connector PV-ZH202 1set Wuxi Xinhongye Wire & Cable Co., Ltd. Ningbo Zhonghuan Electrical Technology Co., Ltd. 11 Al frame 12 Al frame Anodized Aluminum frame 6063 T5, mm Anodized Aluminum frame 6063 T5, mm 2 Jiangyin haida 2 Jiangyin haida 13 Al Corner bonder mm 4 Jiangyin haida 14 Isolation with Back sheet mm 1 FILMCUTTER 15 Isolation with EVA S11, mm 1 Bridgestone Corporation 16 adhesive Guibao 255ml Chengdu Guibao Science and Technology Co., Ltd.

28 DQPVM 210M6-54 Series: Items Components/objects Type or spec Quantity Manufacturer 1 Cells mm 54 2 Soldering strip 0.1 2mm Internal bus 0.2 6mm 11 DONGFANG ELECTRIC (YIXING) MAGI SOLAR POWER TECHNOLOGY CO.,LTD. Shanghai SunBy Solar Technology Co., Ltd. Shanghai SunBy Solar Technology Co., Ltd. 4 Glass mm 1 Tianjin Seedglass Co., Ltd. 5 Back sheet mm 1 FILMCUTTER 6 EVA S11, mm 2 Bridgestone Corporation 7 Junction box PV-ZH010 1 Ningbo Zhonghuan Electrical Technology Co., Ltd. Bypass diode 10SQ050 6 Pan Jit International Inc 9 Cable PV1-F,1 4mm 2,L=900mm 2 Wuxi Xinhongye Wire & Cable Co., Ltd. 10 Connector PV-ZH202 1set Ningbo Zhonghuan Electrical Technology Co., Ltd. 11 Al frame 12 Al frame Anodized Aluminum frame 6063 T5, mm Anodized Aluminum frame 6063 T5, mm 2 Jiangyin haida 2 Jiangyin haida 13 Al Corner bonder mm 4 Jiangyin haida 14 Isolation with Back sheet mm 1 FILMCUTTER 15 Isolation with EVA S11, mm 1 Bridgestone Corporation 16 adhesive Guibao 210ml Chengdu Guibao Science and Technology Co., Ltd.

29 Date sheet for all module types of the family DQPVM240M5-96 Series: Parameters DQPVM220M5-96 DQPVM225M5-96 DQPVM230M5-96 DQPVM235M5-96 DQPVM240M5-96 DQPVM245M5-96 DQPVM250M5-96 DQPVM255M5-96 DQPVM260M5-96 Peak power Pm(W) 220±5% 225±5% 230±5% 235±5% 240±5% 245±5% 250±5% 255±5% 260±5% Open circuit voltage Voc(V) Max. power voltage Vmp(V) Max. power current Imp(A) Short circuit current Isc(A) Dimensions(L*W*H) 150*1065*50 Weigh(kg) 21.5 Max. over-current (A) 10 Max. system voltage (V) Application Class Mono crystalline silicon solar cell No. of cells and connections 1000V DC Class A 125*125*0.19mm 96 series No. of bypass diodes 4 Bypass diode rating (A) 10 Bypass diode max. junction temperature( ) Bypass diode thermal resistance( /W) STC Irradiance:1000W/m 2,Cell temperature:25,am:1.5

30 DQPVM15M5-72 Series: Parameters DQPVM170M5-72 DQPVM175M5-72 DQPVM10M5-72 DQPVM15M5-72 DQPVM190M5-72 DQPVM195M5-72 DQPVM200M5-72 Peak power Pm(W) 170±5% 175±5% 10±5% 15±5% 190±5% 195±5% 200±5% Open circuit voltage Voc(V) Max. power voltage Vmp(V) Max. power current Imp(A) Short circuit current Isc(A) Dimensions(L*W*H) 150*0*45 Weigh(kg) 15.5 Max. over-current (A) 10 Max. system voltage (V) Application Class Mono crystalline silicon solar cell No. of cells and connections 1000V DC Class A 125*125*0.19mm 72 series No. of bypass diodes 3 Bypass diode rating (A) 10 Bypass diode max. junction temperature( ) Bypass diode thermal resistance( /W) STC Irradiance:1000W/m 2,Cell temperature:25,am:1.5

31 DQPVM90M5-36 Series: Parameters DQPVM5M5-36 DQPVM90M5-36 DQPVM95M5-36 Peak power Pm(W) 5±5% 90±5% 95±5% Open circuit voltage Voc(V) Max. power voltage Vmp(V) Max. power current Imp(A) Short circuit current Isc(A) Dimensions(L*W*H) 1200*553*35 Weigh(kg) 7.5 Max. over-current (A) 10 Max. system voltage (V) Application Class Mono crystalline silicon solar cell No. of cells and connections 1000V DC Class A 125*125*0.19mm 36series No. of bypass diodes 3 Bypass diode rating (A) 10 Bypass diode max. junction temperature( ) 200 Bypass diode thermal resistance( /W) 3.0 STC Irradiance:1000W/m 2,Cell temperature:25,am:1.5

32 DQPVM275P6-72 Series: Parameters DQPVM250P6-72 DQPVM255P6-72 DQPVM260P6-72 DQPVM265P6-72 DQPVM270P6-72 DQPVM275P6-72 DQPVM20P6-72 DQPVM25P6-72 DQPVM290P6-72 DQPVM295P6-72 DQPVM300P6-72 Peak power Pm(W) 250±5% 255±5% 260±5% 265±5% 270±5% 275±5% 20±5% 25±5% 290±5% 295±5% 300±5% Open circuit voltage Voc(V) Max. power voltage Vmp(V) Max. power current Imp(A) Short circuit current Isc(A) Dimensions(L*W*H) 1957*992*50 Weigh(kg) 22.5 Max. over-current (A) 15 Max. system voltage (V) 1000V DC Application Class Class A Mono crystalline silicon solar cell No. of cells and connections 156*156*0.2mm 72series No. of bypass diodes 6 Bypass diode rating (A) 10 Bypass diode max. junction temperature( ) 200 Bypass diode thermal resistance( /W) STC 3.0 Irradiance:1000W/m 2,Cell temperature:25,am:1.5

33 DQPVM230P6-60 Series: Parameters DQPVM210P6-60 DQPVM215P6-60 DQPVM220P6-60 DQPVM225P6-60 DQPVM230P6-60 DQPVM235P6-60 DQPVM240P6-60 DQPVM245P6-60 DQPVM250P6-60 Peak power Pm(W) 210±5% 215±5% 220±5% 225±5% 230±5% 235±5% 240±5% 245±5% 250±5% Open circuit voltage Voc(V) Max. power voltage Vmp(V) Max. power current Imp(A) Short circuit current Isc(A) Dimensions(L*W*H) 1650*992*50 Weigh(kg) 19.5 Max. over-current (A) 15 Max. system voltage (V) Application Class Mono crystalline silicon solar cell No. of cells and connections 1000V DC Class A 156*156*0.2mm 60 series No. of bypass diodes 6 Bypass diode rating (A) 10 Bypass diode max. junction temperature( ) Bypass diode thermal resistance( /W) STC Irradiance:1000W/m 2,Cell temperature:25,am:1.5

34 DQPVM210P6-54 Series: Parameters DQPVM190P6-54 DQPVM195P6-54 DQPVM200P6-54 DQPVM205P6-54 DQPVM210P6-54 DQPVM215P6-54 DQPVM220P6-54 DQPVM225P6-54 DQPVM230P6-54 Peak power Pm(W) 190±5% 195±5% 200±5% 205±5% 210±5% 215±5% 220±5% 225±5% 230±5% Open circuit voltage Voc(V) Max. power voltage Vmp(V) Max. power current Imp(A) Short circuit current Isc(A) Dimensions(L*W*H) 142*992*50 Weigh(kg) 17.5 Max. over-current (A) 15 Max. system voltage (V) Application Class Mono crystalline silicon solar cell No. of cells and connections 1000V DC Class A 156*156*0.2mm 54series No. of bypass diodes 6 Bypass diode rating (A) 10 Bypass diode max. junction temperature( ) Bypass diode thermal resistance( /W) STC Irradiance:1000W/m 2,Cell temperature:25,am:1.5

35 DQPVM20M6-72 Series: Parameters DQPVM255M6-72 DQPVM260M6-72 DQPVM265M6-72 DQPVM270M6-72 DQPVM275M6-72 DQPVM20M6-72 DQPVM25M6-72 DQPVM290M6-72 DQPVM295M6-72 DQPVM300M6-72 DQPVM305MP6-72 Peak power Pm(W) 255±5% 260±5% 265±5% 270±5% 275±5% 20±5% 25±5% 290±5% 295±5% 300±5% 305±5% Open circuit voltage Voc(V) Max. power voltage Vmp(V) Max. power current Imp(A) Short circuit current Isc(A) Dimensions(L*W*H) 1957*992*50 Weigh(kg) 22.5 Max. over-current (A) 15 Max. system voltage (V) Application Class Mono crystalline silicon solar cell No. of cells and connections 1000V DC Class A 156*156*0.2mm 72series No. of bypass diodes 6 Bypass diode rating (A) 10 Bypass diode max. junction temperature( ) Bypass diode thermal resistance( /W) STC Irradiance:1000W/m 2,Cell temperature:25,am:1.5

36 DQPVM230M6-60 Series: Parameters DQPVM210M6-60 DQPVM215M6-60 DQPVM220M6-60 DQPVM225M6-60 DQPVM230M6-60 DQPVM235M6-60 DQPVM240M6-60 DQPVM245M6-60 DQPVM250M6-60 Peak power Pm(W) 210±5% 215±5% 220±5% 225±5% 230±5% 235±5% 240±5% 245±5% 250±5% Open circuit voltage Voc(V) Max. power voltage Vmp(V) Max. power current Imp(A) Short circuit current Isc(A) Dimensions(L*W*H) 1650*992*50 Weigh(kg) 19.5 Max. over-current (A) 15 Max. system voltage (V) Application Class Mono crystalline silicon solar cell No. of cells and connections 1000V DC Class A 156*156*0.2mm 60series No. of bypass diodes 6 Bypass diode rating (A) 10 Bypass diode max. junction temperature( ) Bypass diode thermal resistance( /W) STC Irradiance:1000W/m 2,Cell temperature:25,am:

37 DQPVM210M6-54 Series: Parameters DQPVM190M6-54 DQPVM195M6-54 DQPVM200M6-54 DQPVM205M6-54 DQPVM210M6-54 DQPVM215M6-54 DQPVM220M6-54 DQPVM225M6-54 DQPVM230M6-54 Peak power Pm(W) 190±5% 195±5% 200±5% 205±5% 210±5% 215±5% 220±5% 225±5% 230±5% Open circuit voltage Voc(V) Max. power voltage Vmp(V) Max. power current Imp(A) Short circuit current Isc(A) Dimensions(L*W*H) 142*992*50 Weigh(kg) 17.5 Max. over-current (A) 15 Max. system voltage (V) Application Class Mono crystalline silicon solar cell No. of cells and connections 1000V DC Class A 156*156*0.2mm 54series No. of bypass diodes 6 Bypass diode rating (A) 10 Bypass diode max. junction temperature( ) Bypass diode thermal resistance( /W) STC Irradiance:1000W/m 2,Cell temperature:25,am:

38 Label DQPVM240M5-96 Series: DQPVM15M5-72 Series:

39 DQPVM90M5-36 Series: DQPVM275P6-72 Series:

40 DQPVM230P6-60 Series: DQPVM210P6-54 Series:

41 DQPVM20M6-72 Series: DQPVM230M6-60Series:

42 DQPVM210M6-54 Series: Serial Number : the module production date 0001: the number of production components

43 Installation Manual Please read this manual carefully before installing and using the modules. It is the great honor to provide you with our PV modules. In order to enable the PV module to be installed correctly and to generate electric power properly, please read the following operation instruction carefully. 1. Warning: 1. Artificially concentrated sunlight shall not be directed on the module or panel. 2. Application class is class A. 3. Fire resistant roof covering is Class C. 4. Modules rated for use in this application class may be used in systems operating at greater than 50V DC or 240W, where general contact access is anticipated. Modules qualified for safety through this part of IEC61730 and IEC and within this application class are considered to meet the requirements for safety class Ⅱ. 5. Under normal conditions, a photovoltaic module is likely to experience conditions that produce more current and/or voltage than reported at standard test conditions. Accordingly, the value of Isc and Voc marked on this module should be multiplied by of 1.25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. 6. Do not touch live terminals with bare hands. Use insulated tools for electrical connections. 7. To reduce the risk of electrical shock or burns, modules may be covered with an opaque material during installation to avoid shocks or burns.. The installation work of the PV array can only be done under the protection of sun-sheltering covers or sunshades and only qualified person can install or perform maintenance work on this module. 9. Follow the battery manufacture s recommendations if batteries are used with modules. 10. All instructions should be read and understood before attempting to install, wire, operate and maintain the module.

44 11. If instructions are provided allowing modules to be installed in parallel electrically, the installation instructions shall specify that each module (or series string of modules so connected) shall be provided with the maximum series fuse. 2. Unpacking After the PV module has been shipped to the installation site all of the parts should be unpacked properly with care. Caution: The condign environment for unpacking the modules and all other apparatus should be proofed against dampness and rainfall. 3. Preparation before Installation: 1. Optical check before installation, to make sure there is no bug in the packing and junction box as well as the surface of module. 2. Check the series number 3. Check the solar cell modules with irradiance of more than 600W/m 2 and get the voltage. In case the voltage is ZERO, it should NOT be installed and please contact the supplier. 4. Tools & Material for Installation 1 Screwdriver 2 Clamp 3Each mounting hole matches with a set of a screw, a nut and two washer, all made of stainless iron. 4 The users should design and build metallic bracket for installing and bearing the weight of the PV modules. The brackets are specially designed for users installation places such as the open land or on the roof of houses. Caution: To avoid damage from flooding and other unpredictable events, and avoid heavy impact. To design a gradient angle facing the sun radiation direction in order to insure the full sunshine receives as much as possible.

45 4. Installation and operation 1. Systems should be installed by qualified personnel only and at least two persons. The system involves electricity, and can be dangerous if the personnel are not familiar with the appropriate safety procedures. 2. Do not step on the module. 3. Although modules are quite rugged, the glass can be broken (and the module will no longer work properly) if it is dropped or hit by tools or other objects. 4. Put the solar cell modules on the frame and put on the screws and then combine them firmly after put on all the washers. All the screw caps should be finished on the frame together firmly. The module frame is made of anodized aluminum, and therefore corrosion can occur if the module is subject to a salt-water environment with contact to a rack of another type of metal. (Electrolysis Corrosion) if required. PVC or stainless steel washers can be placed between the solar module frame and support structure to prevent this corrosion. 5. The solar module frame must be attached to a support structure using M stainless steel hardware of four (4) places symmetrical on the DQPVM90M5-36 Series solar module and attached to a support structure using M stainless steel hardware of eight () places symmetrical on the other solar module. The stainless steel hardware used for securing the module frame should secure with an applied torque of 6 foot-pounds ( Newton-meters). The recommended standoff height is 20 cm. If other mounting means are employed this may affect the TUV Listing or the fire class ratings, the incline angle α to be adjusted according to local condition.

46 Stainless steel M nut 2 Stainless steel washer 3 Stainless steel M t-head bolt The module has been evaluated by TUV for mounting using the provided mounting holes in the frame. 6.Way of grounding: All module frames should be grounded for safety. The grounding connections between modules must be approved by a qualified electrician, the grounding itself must be made by a qualified electrician. The ground wire should be at least the same size as the electrical conductors, ground wires no less than 12AWG are recommended. 3 A A WASHER 1. Stainless steel M4 nut 2. Stainless steel serrated washer 3. Stainless steel washer 4. Stainless steel cupped-shape washer 5. Stainless steel M4 t-head bolt 7. Module support structures that are to be used to support modules should be

47 wind rated and approved for use by the appropriate local and civil codes prior to installation.. When solar modules are used to charge batteries, the battery must be installed in a manner, which will protect the performance of the system and the safety of its users. Follow the battery manufacturer s guidelines concerning installation, operation and maintenance recommendations. In general, the battery (or battery bank) should be away from the main flow of people and animal traffic. Select a battery site that is protected from sunlight, rain, snow, debris, and is well ventilated. Most batteries generate hydrogen gas when charging, which can be explosive. Do not light matches or create sparks near the battery bank. When a battery is installed outdoors, it should be placed in an insulated and ventilated battery case specifically designed for the purpose. 9. In most applications, PV modules should be installed in a location where they will receive maximum sunlight throughout the year. In the Northern Hemisphere, the modules should typically face south, and in the Southern Hemisphere, the modules should typically face north. Modules facing 30 degrees away from true South (or north) will lose approximately 10 to 15 percent of their power output. If the module faces 60 degrees away from true South (or North), the power loss will be 20 to 30 percent. When choosing a site, avoid trees, buildings or obstructions, which could cast shadows on the solar. 5. Wiring and Connection: 1. Before this procedure, please read the operation instructions of the PV control system carefully. 2. The cable diameter is 4mm 2,type is PV1-F, 1*4.0mm 2.Max. Temperature at conductor is 120, Ambient Temperature is -40 ~+90. Manufacturer is Wuxi Xinhongye Wire & Cable Co., Ltd.

48 3.The connector type is PV-ZH202. Ambient Temperature is -40 ~+5. Manufacturer is Ningbo Zhonghuan Electrical Technology Co., Ltd. 4. The bypass diode type is 10SQ050, Manufacturer is Pan Jit International Inc Partial shading of an individual module can cause a reverse voltage across the shaded module. Current is then forced through the shaded area by the other modules. When a bypass diode is wired in parallel with the series string, the forced current will flow through the diode and bypass the shaded module, thereby minimize module heating and array current losses. Diodes are used as bypass diodes. Have a Rated Average Forward Current 10A.Above maximum system current at highest module operating temperature. Have a Rated Repetitive Peak Reverse Voltage 50V. Above maximum system voltage at lowest module operating temperature. 5. When designing the system, we recommend that the maximum number of modules in parallel should be no more than four while the maximum number of modules in series no more than eight. 6. Make wiring by Multi-connecting cables between the PV modules in series or parallel connection, which is determined by user s configuration requirement for system power, current and voltage. 7. Open the connection box of the control system and connect the cabled from the PV arrays to the connection box in accordance with the installation indication of the PV control systems.. All module frames and mounting racks must be properly grounded in accordance with local and national electrical codes. 9. Follow the requirements of applicable local and national electrical codes.

49 6. Maintenance and Care: 1. A built up of dust or dirt on the module(s) front face will result in a decreased energy output. Clean the panel(s) preferably once per annum if possible (dependant on site conditions) using a soft cloth dry or damp, as necessary. 2. Never use abrasive material under any circumstances. 3. Examine the PV module(s) for signs of deterioration. Check all wiring for possible rodent damage, weathering and that all connections are tight and corrosion free. Check electrical leakage to ground. 4. Check fixing screws and mounting brackets are tight, adjust and tighten as necessary. Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. 666 West Jinshajiang Road,Deyang City,Sichuan Province,P.R.China TEL: FAX:

50 Appended index Annex1: 1. Copy of certificate of junction box 2. Test report for PYE according to IEC

51 Dongfang Electric Group Dongqi Investment&Development Co.,Ltd. Annex 2:

52 Annex 3: Dongfang Electric Group Dongqi Investment&Development Co.,Ltd.

53 Annex 4: Dongfang Electric Group Dongqi Investment&Development Co.,Ltd.

54

55 Annex 5: Dongfang Electric Group Dongqi Investment&Development Co.,Ltd.

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES TM FULL RANGE OF CERTIFIED MODULES Mono Crystalline Watt to 50 Watt Poly (Multi) Crystalline Watt to 80 Watt Glass Cells High Efficiency A-Grade

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality Test Report Salt Mist corrosion Testing of Photovoltaic modules acc IEC 61701-2011 TÜV Report No: 19630874.001 Bangalore JULY 2016 Certificate No.

More information

Test Report. File No.: SHV01023/16 Test Report No.: Taizhou, Zhejiang , P.R. China

Test Report. File No.: SHV01023/16 Test Report No.: Taizhou, Zhejiang , P.R. China Applicant... : Manufacturer... : Order No.... : Zhejiang ERA Solar Technology Co., Ltd. Sihai Road, Huangyan Economic Development Zone Taizhou, Zhejiang 318020, P.R. China Zhejiang ERA Solar Technology

More information

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China Applicant... : Manufacturer... : Order No.... : Zhejiang ERA Solar Technology Co., Ltd. Sihai Road, Huangyan Economic Development Zone, Taizhou, Zhejiang 318020, P.R. China Zhejiang ERA Solar Technology

More information

INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES

INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES - Page 1/13. Appendix II - CONTENT 1. INTRODUCTION...3 2. TECHNICAL DATA...3 3. PROTECTION DIODES...6 4.

More information

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty Those who dream of a better future can help lead to a more meaningful and enriched world. As a leading solar module manufacturer in Korea, we never stop to achieve competitiveness through differentiation,

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002 Bangalore, May 2017 Certificate No. T -1543 2 / 17 Contents CONTENTS... 2

More information

Test Report. File No.: SHV01032/18-02 Test Report No.:

Test Report. File No.: SHV01032/18-02 Test Report No.: File No.: SHV01032/18-02 No.: 492011003.001 Applicant... : Manufacturer 1... : Manufacturer 2... : Order No.... : Suzhou Akcome Optronics Science &Technology Co., Ltd. Jintang Rd, Zhangjiagang Economic

More information

APS M1P Single-phase Micro-inverter Installation and User Manual

APS M1P Single-phase Micro-inverter Installation and User Manual APS M1P Single-phase Micro-inverter Installation and User Manual Version: 1.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR

More information

APS M1P Single-phase Micro-inverter Installation and User Manual

APS M1P Single-phase Micro-inverter Installation and User Manual APS M1P Single-phase Micro-inverter Installation and User Manual Version: 2.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR

More information

Page 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37

Page 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37 Page 1 of 37 Test Report issued under the responsibility of: TEST REPORT IEC 61215 PV Module Safety Qualification Requirements for testing Report Reference No.... : ULI-NABL(ELT)-MNRE-0053/2011 Date of

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality Test Report Salt Mist corrosion Testing of Photovoltaic modules acc IEC 61701-2011 TÜV Report No: 19631432.001 Bangalore July 2017 2 / 19 Contents:

More information

SRS-200 Solar Radiation Sensor Installation and Setup Instructions. SRS-200 with optional Leveling Plate and Mounting Bracket. Revision 2.0.

SRS-200 Solar Radiation Sensor Installation and Setup Instructions. SRS-200 with optional Leveling Plate and Mounting Bracket. Revision 2.0. SRS-200 with optional Leveling Plate and Mounting Bracket SRS-200 Solar Radiation Sensor Installation and Setup Instructions Revision 2.0 July 2018 Pace Scientific Inc www.pace-sci.com Tel: 704-799-0688

More information

BLACK WIDOW COMPOSITE

BLACK WIDOW COMPOSITE PAGE-1 UPDATED 3-6-2015 REV.1 BLACK WIDOW COMPOSITE Detailed installation manual PAGE-2 UPDATED 3-6-2015 SpiderRax, Inc. REVISION PAGE Installation Manual For BWC-S, BWC-B,BWC-F DATE PAGES REASON OLD LEVEL

More information

Your Origin SLIVER system will be supplied with one of the following sets of panels:

Your Origin SLIVER system will be supplied with one of the following sets of panels: SLIVER3000 Solar System Panel Specifications Your Origin SLIVER system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum

More information

CP /240-MC4 User Manual

CP /240-MC4 User Manual CP-250-60-208/240-MC4 User Manual Chilicon Power LLC Jan 2014 1 CONTENTS Important Safety Instructions... 3 Safety Instructions... 3 CP-250 Microinverter System Introduction... 4 Inverter Label Information...

More information

UPDATED REV.5 BLACK WIDOW. Detailed installation manual. Patent pending P/N: BW-S, BW-B, BW-F.

UPDATED REV.5 BLACK WIDOW. Detailed installation manual. Patent pending P/N: BW-S, BW-B, BW-F. PAGE-1 UPDATED 2-3-2015 REV.5 BLACK WIDOW Detailed installation manual PAGE-2 UPDATED 2-3-2015 SpiderRax, Inc. REVISION PAGE Installation Manual For BW-S, BW-B,BW-F DATE PAGES REASON OLD LEVEL NEW LEVEL

More information

USER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications

USER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications USER MANUAL Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications Models: BMOD0125 P064 B02 BMOD0094 P075 B02 Document #1014204 Notice: The products described

More information

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003) (Part # S-LIB-M003) The smart sensor is designed to work with the HOBO Weather Station logger. The smart sensor has a plug-in modular connector that allows it to be added easily to a HOBO Weather Station.

More information

MOUNTING INSTRUCTIONS CONCRETE PURLIN BRACKET

MOUNTING INSTRUCTIONS CONCRETE PURLIN BRACKET CONCRETE PURLIN BRACKET VERSION MARCH 2015 GENERAL INSTRUCTIONS Safety: Systems may only be installed and operated by properly trained and technically suitable people (i.e. MCS accredited installers).

More information

28" Adjustable Solar Tilt Mount ADJ-28. Owner's Manual. Please read this manual BEFORE installing your solar tilt mount

28 Adjustable Solar Tilt Mount ADJ-28. Owner's Manual. Please read this manual BEFORE installing your solar tilt mount 28" Adjustable Solar Tilt Mount ADJ-28 Owner's Manual Please read this manual BEFORE installing your solar tilt mount SECTION 1 Introduction Mounting your solar panel inclined to an optimized angle with

More information

MTS-SP100. RENOGY Pole Mount System E Philadelphia St, Ontario, CA Version: 1.2

MTS-SP100. RENOGY Pole Mount System E Philadelphia St, Ontario, CA Version: 1.2 MTS-SP100 RENOGY Pole Mount System 2775 E Philadelphia St, Ontario, CA 91761 1-800-330-8678 1 Version: 1.2 Important Safety Instructions Please save these instructions. This manual contains important safety,

More information

Instructions For Installing A Pig Fence

Instructions For Installing A Pig Fence Instructions For Installing A Pig Fence A Multi-wire Fence on a Single Line of Posts Height: 18 Inches Polywire for seasonally removable fences Aluminum wire for permanent fences These pages provide the

More information

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document USER MANUAL Maxwell Technologies Ultracapacitor Energy Storage Modules Models: BMOD0058 E016 B02 BMOD0006 E160 B02 Document 3000200.1 Notice: The products described herein are covered by one or more of

More information

APPENDIX V PRODUCT SHEETS

APPENDIX V PRODUCT SHEETS National Institutes of Health Building 37 Modernization Bethesda, Maryland APPENDIX V PRODUCT SHEETS Katie L. McGimpsey Mechanical Option 1 of 4 BP 4160 160-Watt Monocrystalline Photovoltaic Module The

More information

FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER #

FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER # ZOMEWORKS FXL-168 FIXED RACK ASSEMBLY INSTRUCTIONS SALES ORDER # 1 1011 Sawmill Road NW, PO Box 25805, Albuquerque, NM 87125 USA (505) 242-5354 / (800) 279-6342 / FAX (505) 243-5187 E-mail: zomework@zomeworks.com

More information

CSS Central Mount System

CSS Central Mount System CSS-20 Installation Manual CSS-20 Safety Notifications Below are the installation instructions for the CSS-20-2 Long Span Beam Mounting System. Please read these safety notifications prior to beginning

More information

Installation/User Manual

Installation/User Manual Installation/User Manual APS YC500-A Photovoltaic Grid-connected Inverter Version 4.1 1/15 APS America 1015 Hostmark St. Ste 104; Poulsbo, WA 98370 TEL: 206-855-5100 EMAIL: info@apsamerica.com WEB: www.apsamerica.com

More information

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM EN mounting system for insulated pitched roof Bitumen / EPDM for solar panels landscape setup ESDEC BV 2015 TABLE OF CONTENT 1. Introduction 1 2. General installation

More information

Model UT20B: OPERATING MANUAL Table of Contents (1)

Model UT20B: OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols Rotary Switch Display Symbols Measurement Operation A. AC Voltage

More information

Installation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna

Installation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna Release 3.0 NN47251-311 Issue 02.01 June 2014 Installation Job Aid (English) for Avaya WLAN 8100 series- WLAN AP 8120 with External Antenna How to get help To access the complete range of services and

More information

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years

More information

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions www.we-llc.com Outline Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions Bonding & Grounding Grounding Terms Equipment Grounding: The National Electrical

More information

Marking label of DelSolar module type D6M240B3A

Marking label of DelSolar module type D6M240B3A age 2 of 19 Report Ref. No. 61.410.11.029.01 Summary of testing: Tests performed (name of test and test clause): Testing location: Clause 6, Initial measurements: - Visual inspection - Maximum power determination

More information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE INSTALLATION, OPERATION AND MAINTENANCE GUIDE FOR INDOOR/OUTDOOR SINGLE PHASE ENCAPSULATED TRANSFORMERS Indoor/Outdoor Encapsulated Transformers The pictures used in this guide are only a representation

More information

Page 1 of 19 Report Ref. No.: TEST REPORT IEC 62716:2013

Page 1 of 19 Report Ref. No.: TEST REPORT IEC 62716:2013 age 1 of 19 Report Ref. No.: 704061718718-00 TEST REORT IEC 62716:2013 TÜV SÜD Test report for photovoltaic (V) modules Ammonia corrosion testing Report reference No.... : 704061806701-00 Date of issue...

More information

LJ element beam for 10 or 12 meters INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment

LJ element beam for 10 or 12 meters INSTRUCTION MANUAL. CAUTION: Read All Instructions Before Operating Equipment LJ-113 3 element beam for 10 or 1 meters INSTRUCTION MANUAL CAUTION: Read All Instructions Before Operating Equipment 308 Industrial Park Road Starkville, MS 39759 USA Tel: 66-33-9538 Fax: 66-33-6551 VERSION

More information

4 INSTALLATION Requirements on Installation Securing Space Before installing the Panaboard, be sure to secure space shown in section 2.6.

4 INSTALLATION Requirements on Installation Securing Space Before installing the Panaboard, be sure to secure space shown in section 2.6. 4 INSTALLATION The Panaboard is used by hanging it on the wall or installing it on the stand (sold separately as an option). When using the Panaboard by hanging it on the wall, refer to the description

More information

AWNING SYSTEM INSTALLATION INSTRUCTIONS ALL VERTICAL WALLS

AWNING SYSTEM INSTALLATION INSTRUCTIONS ALL VERTICAL WALLS INSTALLATION MANUAL AWNING SYSTEM INSTALLATION INSTRUCTIONS ALL VERTICAL WALLS TABLE OF CONTENTS Table of Contents... 3 Components... 4 System Components... 6 Attachment Components... 7 Module Compatibility...

More information

Installation & Operating Manual. iwap202

Installation & Operating Manual. iwap202 Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and

More information

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0 Touch Switch Unique 18 mm Capacitive Touch Switch with Choice of Three Actuators is Activated with Only a Very Slight Physical Contact Lightweight objects, such as thin wire or foil can be accurately detected.

More information

Item# " VARIABLE SPEED BENCH GRINDER USER'S MANUAL

Item#  VARIABLE SPEED BENCH GRINDER USER'S MANUAL Power Tools Item# 33309 3" VARIABLE SPEED BENCH GRINDER USER'S MANUAL Read carefully and understand RULES FOR SAFE OPERATION and instructions before operating. Failure to follow the safety rules and other

More information

LF Conductivity Measuring Probe

LF Conductivity Measuring Probe LF Conductivity Measuring Probe Contents 1 General 1.1 Introduction 1.2 Application range 2 Safety 2.1 Warnings and symbols 3 Transport and storage 4 Application 5 Measuring principle 6 Assembly 7 Construction

More information

Quality criteria and certificates

Quality criteria and certificates Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years

More information

MC CHANGER CABINET INSTALLATION INSTRUCTIONS

MC CHANGER CABINET INSTALLATION INSTRUCTIONS 8M00356 REV. 10 www.standardchange.com 1-800-968-6955 Technical Phone Support is from 8:00AM to 7:30PM E.S.T., Monday-Friday Walk-in Service is from 8:00AM to 4:30PM E.S.T., Monday-Friday Parts Department

More information

Access Hatch. Installation Instructions and Operators Manual. PS DOORS Contact Information. Model AH-710 Standard High Neck Radius Cut

Access Hatch. Installation Instructions and Operators Manual. PS DOORS Contact Information. Model AH-710 Standard High Neck Radius Cut Access Hatch Installation Instructions and Operators Manual Standard Low Profile Frame Model AH-710 Standard High Neck Radius Cut High Neck Frame for special applications. Table of Contents Warranty Information...2

More information

INSTRUCTION MANUAL. Specifications Mechanical. 1 5/8 to 2 1/16 O.D. (41mm to 52mm)

INSTRUCTION MANUAL. Specifications Mechanical. 1 5/8 to 2 1/16 O.D. (41mm to 52mm) 308 Industrial Park Road Starkville, MS 39759 USA Ph: (662) 323-9538 FAX: (662) 323- General Description Model VB-25FM 2-Meter 5 Elements Beam INSTRUCTION MANUAL This antenna is a 5-element, 2-meter beam

More information

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02 Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02 Installation Guide WirelessSet485-IEN091511 98-0009411 Version 1.1 EN SMA Solar Technology AG Table of Contents Table of Contents 1 Notes

More information

Installation Instructions. Materials Needed. Parts Included. Tools You Will Need

Installation Instructions. Materials Needed. Parts Included. Tools You Will Need Installation Instructions 27 Built In Wall Oven JKP15, JKP18, JKP27, JKP45, JKP56 JKS05, ZEK937, ZEK957 If you have questions, call 800-GE-CARES or visit our website at: www.geappliances.com Before you

More information

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm)

Standard Pole Mount Parabolic Antenna Mounting Instructions 3 ft. (90cm) & 4 ft. (120cm) 495 R Billerica Ave. N. Billerica, MA 01862 USA Tel: (978) 459-8800 Fax: (978) 459-3310 / 8814 www.radiowavesinc.com email: sales@radiowavesinc.com Standard Pole Mount Parabolic Antenna Mounting Instructions

More information

19" EIA SRD Swing Rack Installation Instructions

19 EIA SRD Swing Rack Installation Instructions 19" EIA SRD Swing Rack Installation Instructions 1-866-TRY-GLCC (879-4522) PREFACE This manual is provided to prevent service personnel from committing an act that results in the risk of fire, electric

More information

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4 I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)

More information

SILVERBACK INSTALLATION MANUAL

SILVERBACK INSTALLATION MANUAL SILVERBACK INSTALLATION MANUAL R-SERIES SOLAR RACKS T OLL FREE 866-766-3727 WWW.ROOFSCREEN.COM Introduction... 2 The Silverback Solar Racking System... 2 This manual... 2 Application... 2 System Overview...

More information

Tel: Fax:

Tel: Fax: Grid Tie Solar Inverter Operator's Manual SG-4000 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS To reduce the risk of electrical shock and to ensure safe installation and operation of Grid Tie

More information

MANUAL MOUNTING SYSTEM FOR CORRUGATED ROOF

MANUAL MOUNTING SYSTEM FOR CORRUGATED ROOF MANUAL MOUNTING SYSTEM FOR CORRUGATED ROOF EN mounting system for corrugated roof for solar panels in portait setup (cross-system) ESDEC BV 2015 TABLE OF CONTENT 1. Introduction 1 2. General installation

More information

Fixed PV Module. Installation Manual

Fixed PV Module. Installation Manual Fixed PV Module Installation Manual Introduction Congratulations. You are now the proud owner of a fine Sundaya product. May you enjoy its usefulness for many years to come. This manual will show you how

More information

Model VB-23FM 2-Meter 3-Element Beam

Model VB-23FM 2-Meter 3-Element Beam 308 Industrial Park Road Starkville, MS 39759 USA Ph: (662) 323-9538 FAX: (662) Model VB-23FM 2-Meter 3-Element Beam [ INSTRUCTION MANUAL Figure 1 Overall View and Boom Detail GENERAL DESCRIPTION This

More information

Model : OPERATING MANUAL Table of Contents (1)

Model : OPERATING MANUAL Table of Contents (1) Table of Contents (1) Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Measurement Operation A. DC

More information

iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas

iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas iant200 iant212 iant213 iant214 iant215 iant216 iant217 iant218 iant219 iant220 iant221 iant222 Operating Manual iant2xx Series of Antennas This page is intentionally left blank. Document Number 403449

More information

TBX-1329 AC/DC COUPLING TERMINAL BLOCK

TBX-1329 AC/DC COUPLING TERMINAL BLOCK INSTALLATION GUIDE TBX-1329 AC/DC COUPLING TERMINAL BLOCK Introduction This guide describes how to install and use the TBX-1329 AC/DC coupling terminal block with the SCXI-1120, SCXI-1120D, and SCXI-1121

More information

Nuclear Associates

Nuclear Associates Nuclear Associates 07-443 Clamshell Densitometer Users Manual February 2005 Manual No. 166001 Rev. 5 2004, 2005 Fluke Corporation, All rights reserved. Printed in U.S.A. All product names are trademarks

More information

Maintenance and other important non-personal injury and non-material damage instructions or statements that should be observed.

Maintenance and other important non-personal injury and non-material damage instructions or statements that should be observed. VIGO INDUSTRIES INSTALLATION GUIDE FOR SHOWER ENCLOSURE ()! SAFETY PRECAUTIONS This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated

More information

Outdoor Water Solutions, Inc. 9 Backyard Windmill. Installation Manual

Outdoor Water Solutions, Inc. 9 Backyard Windmill. Installation Manual Outdoor Water Solutions, Inc. 9 Backyard Windmill Installation Manual Customer Service: -866-7-6 Website: www.outdoorwatersolutions.com Springdale, Arkansas 72762 Phone: -866-7-6 Fax: (79) 750-978 Thank

More information

MM22 Enclosure Mount C228M-B (4/14)

MM22 Enclosure Mount C228M-B (4/14) I N S T A L L A T I O N MM22 Enclosure Mount C228M-B (4/14) Important Safety Instructions 1. Installation and servicing should be done only by qualified service personnel and conform to all local codes.

More information

SUMMERHOUSE PERGOLA ASSEMBLY INSTRUCTIONS. Toll-free: MODEL NO

SUMMERHOUSE PERGOLA ASSEMBLY INSTRUCTIONS. Toll-free: MODEL NO SUMMERHOUSE PERGOLA MODEL NO. 088-1759-2 INSTRUCTIONS Toll-free: 1-888-670-6684 IMPORTANT: Please read this manual carefully before beginning assembly of this product. Keep this manual for future reference.

More information

S OLAR RADIATION S HIELD MANUAL

S OLAR RADIATION S HIELD MANUAL S OLAR RADIATION S HIELD MANUAL This instruction manual is designed to take you step-by-step through the process required to assemble and mount your Solar Radiation Shield. Please take the time to read

More information

K1FO 12 ELEMENT 144/147 MHz YAGI

K1FO 12 ELEMENT 144/147 MHz YAGI K1FO 12 ELEMENT 144/147 MHz YAGI WARNING: INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS. FOR YOUR SAFETY FOLLOW THE INSTALLATION DIRECTIONS. Ariane Arrays, Inc. Copyright 2006 201 Hopedale

More information

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N)

Cisco Aironet 2.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT2588P3M-N) Cisco Aironet.4-GHz/5-GHz 8-dBi Directional Antenna (AIR-ANT588P3M-N) This document outlines the specifications for the Cisco Aironet AIR-ANT588P3M-N.4/5-GHz 8-dBi 3-Port Directional Antenna with N-connectors

More information

Mounting Instructions for Cisco Aironet 1550 Series Outdoor Access Point Pole-Mount Kits

Mounting Instructions for Cisco Aironet 1550 Series Outdoor Access Point Pole-Mount Kits Mounting Instructions for Cisco Aironet 1550 Series Outdoor Access Point Pole-Mount Kits Date: April 2011 Part number: This document describes how to use the Cisco Aironet 1550 Series Outdoor Access Point

More information

Application Tooling Specification Sheet

Application Tooling Specification Sheet Tool Kit Order No. 63823-6470 FEATURES Application Tooling Specification Sheet Hand Crimp Tool Order No. 63823-6400 % A full cycle ratcheting hand tool ensures complete crimps % Ergonomically designed

More information

Peak Style Shelter Assembly Instructions

Peak Style Shelter Assembly Instructions 6' x 10' x 6'6" Shed-in-a-Box Peak Style Shelter Assembly Instructions Description Model # 6' x 10' x 6'6" Shed-in-a-Box - Gray 70403 Recommended Tools Please read instructions COMPLETELY before assembly.

More information

SILICon IrrADIAnCe SenSor

SILICon IrrADIAnCe SenSor Measurement of Solar Silicon irradiance sensors (Si sensor) show a cost-effective, but rugged and reliable solution for the measurement of solar irradiance, especially for the monitoring of Photovoltaic

More information

Curium 19H Installation Instructions & Parts List

Curium 19H Installation Instructions & Parts List Curium 19H Installation Instructions & Parts List Illustration Curium 19H Right Hand Page 1 of 15 01/07/2016 Revision 2.1 IMPORTANT This shower screen / enclosure must be installed by suitably qualified

More information

Digital Clamp Meter Model: &

Digital Clamp Meter Model: & Digital Clamp Meter Model: 72-7224 & 72-7226 1 SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This meter is designed to meet IEC61010-1, 61010-2-032,

More information

INSTRUCTION MANUAL. Specifications Electrical. Front-To-Back Ratio VSWR at Resonance Less than 1.5:1 Nominal Impedance. Mechanical

INSTRUCTION MANUAL. Specifications Electrical. Front-To-Back Ratio VSWR at Resonance Less than 1.5:1 Nominal Impedance. Mechanical 300 Industrial Park Road, Starkville, MS 39759 Ph: (662) 323-8538 FAX: (662) 323-6551 TH-3JRS Tri-band HF 3 Elements Beam Covers 10, 15 and 20 Meters INSTRUCTION MANUAL WARNING Installation of this product

More information

2015 RIGOL TECHNOLOGIES, INC.

2015 RIGOL TECHNOLOGIES, INC. Service Guide DG000 Series Dual-channel Function/Arbitrary Waveform Generator Oct. 205 TECHNOLOGIES, INC. Guaranty and Declaration Copyright 203 TECHNOLOGIES, INC. All Rights Reserved. Trademark Information

More information

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL SINGLE PHASE INSTRUCTION MANUAL DIAGRAM D This manual applies to all single-phase buck & boost transformers sold by Larson Electronics. Please refer to the connection diagram on pages 4-6 for properly

More information

SolarMount (E)volution

SolarMount (E)volution SolarMount (E)volution SOLARMOUNT (E)VOLUTION: THE BEST JUST GOT BETTER. Engineering, Excellence, and Ease. Performance Engineered for versatility and reduced installation time, SolarMount (E)volution

More information

Resysta 6 and 4 Flat Board Siding System Assembly Installation Guidelines

Resysta 6 and 4 Flat Board Siding System Assembly Installation Guidelines Resysta 6 and 4 Flat Board Siding System Assembly Installation Guidelines NOTE: Proper planning of the siding layout is essential for ease of installation of siding boards and siding components. Thoroughly

More information

YUKON PATIO COVER INSTALLATION INSTRUCTIONS

YUKON PATIO COVER INSTALLATION INSTRUCTIONS YUKON PATIO COVER INSTALLATION INSTRUCTIONS Before You Begin: Consult your local building department for any required permits You may be required to obtain a building permit for this structure. Contact

More information

USER MANUAL RM050A-R3, RM051A-R3 WALLMOUNT RACKS 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.COM

USER MANUAL RM050A-R3, RM051A-R3 WALLMOUNT RACKS 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.COM USER MANUAL RM050A-R3, RM051A-R3 ULTRA WALLMOUNT RACKS 24/7 AT OR VISIT BLACKBOX.COM TABLE OF CONTENTS PREFACE... 3 Safety Symbols Used in this Manual...3 Safety Considerations...3 1. SPECIFICATIONS...

More information

TECHNICAL MANUAL OPERATION AND INSTALLATION INSTRUCTIONS ANTENNA AS-3771B/U. Document No: VTM /C

TECHNICAL MANUAL OPERATION AND INSTALLATION INSTRUCTIONS ANTENNA AS-3771B/U. Document No: VTM /C TECHNICAL MANUAL OPERATION AND INSTALLATION INSTRUCTIONS ANTENNA AS-3771B/U Document No: Valcom Manufacturing Group, Inc. 175 Southgate Drive, P.O.Box 603, Guelph, Ontario, Canada N1H 6L3 Tel: 519-824-3220

More information

Assembly Instructions

Assembly Instructions Assembly Instructions 10'x12' Aluminum Gazebo Item: L-GZ399PAL-B Our clear, easy-to-follow, step-by-step instructions will guide you through the project from start to finish. The final product will be

More information

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents

Model 4210-MMPC-L. Multi-measurement Prober Cable Kit. Overview. Quick start guide topics. Related documents Model 0-MMPC-L Keithley Instruments, Inc. Multi-measurement Prober Cable Kit 877 Aurora Road Quick Start Guide Cleveland, Ohio 9-888-KEITHLEY http://www.keithley.com Overview The Keithley Instruments Model

More information

southpaw enterprises, inc.

southpaw enterprises, inc. southpaw enterprises, inc. Instruction Sheet C-STAND 7100 Store these instructions in a safe place or with the enclosed maintenance checklist Take time to familiarize yourself with the use and maintenance

More information

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15 MOUNT INSTALLATION GUIDE PUB5JUN5 Wrenches and Torque SM SOLAR Wrench Size Recommended Torque (ft-lbs) /4 Hardware 7/6 *0 3/8 Hardware 9/6 *30 # Hardware 5/6 0 Torques are not designed for use with wood

More information

Aluminum Lake Truss Dock Instructions

Aluminum Lake Truss Dock Instructions Table of Contents Aluminum Lake Truss Dock Instructions 1. Dock Assembly and Set-Up 1.1 Quick Start 1.2 Positioning Quick Clips 1.3 Installing Dock Legs 1.4 Installing Foot Pads 1.5 Installing Cross Braces

More information

Cisco Aironet 13.5-dBi Yagi Mast Mount Antenna (AIR-ANT1949)

Cisco Aironet 13.5-dBi Yagi Mast Mount Antenna (AIR-ANT1949) Cisco Aironet 13.5-dBi Yagi Mast Mount Antenna (AIR-ANT1949) Overview This document describes the 13.5-dBi Yagi mast mount antenna and provides instructions for mounting it. The antenna operates in the

More information

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English

Instruction manual SUN-PM100L. SUN-PM100L Polishing Machine English Instruction manual SUN-PM100L SUN-PM100L Polishing Machine English Table: SUN-UM-TL-PM001 Version: A/0 Fiber Optic Solutions Provider Ⅰ Safety Precautions To ensure safe operation and maximize product

More information

LED MIRROR CABINETS 3612-L-6560

LED MIRROR CABINETS 3612-L-6560 LED MIRROR CABINETS 3722-L-5070 3760-L-5060 3612-L-6560 BEFORE YOU START, HERE IS SOME IMPORTANT INFORMATION. 1) General Information Please inspect this product upon delivery. Any missing parts or manufacturing

More information

Page 1 of 6 Systems Inc.

Page 1 of 6 Systems Inc. Page 1 of 6 This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions

More information

Ior DIGITAL LEAKAGE CLAMP TESTER MCL-400IR INSTRUCTION MANUAL

Ior DIGITAL LEAKAGE CLAMP TESTER MCL-400IR INSTRUCTION MANUAL Ior DIGITAL LEAKAGE CLAMP TESTER MCL-400IR INSTRUCTION MANUAL Thank you very much for selecting our model MCL-400IR Ior Leakage Clamp Tester. Before use the instrument, read this instruction manual completely

More information

Outdoor Water Solutions, Inc. Small Backyard Windmill. Installation Manual

Outdoor Water Solutions, Inc. Small Backyard Windmill. Installation Manual Outdoor Water Solutions, Inc. Small Backyard Windmill Installation Manual Customer Service: 1-866-471-1614 Website: www.outdoorwatersolutions.com Springdale, Arkansas 72764 Phone: 1-866-471-1614 Fax: 1-479-750-9178

More information

8" BENCH SHEAR INSTRUCTIONS. Item #20198

8 BENCH SHEAR INSTRUCTIONS. Item #20198 8" BENCH SHEAR INSTRUCTIONS Item #20198 Your EASTWOOD 8 BENCH SHEAR for metal cutting is designed for quickly and cleanly cutting mild steel, aluminum and other metals. Torque-amplifying, compound linkage

More information

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range Growatt 2000TL Maximum efficiency of 97% and wide inpunt voltage range Internal DC switch Transformerless GT topology Compact design Multi MPP controller MTL - String Bluetooth / RF technology / ZigBee

More information

Ashley Dressing Table And Stool

Ashley Dressing Table And Stool Ashley Dressing Table And Stool Assembly Instructions - Please keep for future reference 719/179 719/3161 Dimensions Width - 80cm Depth - 39cm Height - 6.7cm Dimensions Width - 30cm Depth - 30cm Height

More information

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01 MOUNT INSTALLATION GUIDE PUB5JAN0 SM SOLAR Wrenches and Torque Wrench Size Recommended Torque (ft-lbs) /4 Hardware 7/6 *0 3/8 Hardware 9/6 *30 # Hardware 5/6 0 Torques are not designed for use with wood

More information

GE Monogram. Installation. Instructions. 36" Vent Hood. Model ZV750. Call anywhere in the US and Canada -

GE Monogram. Installation. Instructions. 36 Vent Hood. Model ZV750. Call anywhere in the US and Canada - at :: rangehoods. com GE Monogram Instructions Model ZV750 GE Monogram at:: rangehoods. com is a division of CAUTION WARNING Before you begin Read these instructions completely and carefully. IMPORTANT:

More information

Essex Gazebo. Assembly Instructions. Model No

Essex Gazebo. Assembly Instructions. Model No Essex Gazebo Model No. 088-1336-8 Instructions Toll-free: 1-877-483-6759 IMPORTANT: Please read this manual carefully before beginning assembly of this product. Keep this manual for future reference. Made

More information

1 of 9 SITE PLAN modules at 325W kw. Sample GAMECHANGE SOLAR. Sample. Sample AERIAL VIEW. Array Information. Design Information.

1 of 9 SITE PLAN modules at 325W kw. Sample GAMECHANGE SOLAR. Sample. Sample AERIAL VIEW. Array Information. Design Information. AERIAL VIEW Array Information PV Modules Racking Manufacturer Hyundai Gamechange Racking Model HiS-S325TI 5-Degree GC Grid-Lite Dimensions." x 39.29" x.9" Weight 5. lbs Quantity 224 224 modules at 325W

More information