1 Product Information PI TOSHIBA X-RAY TUBE D-045 Stationary Anode X-ray Tube Especially designed for dental radiography unit. This tube has focus 0.4, and is available for maximum tube voltage 70 kv. Installed in the same enclosure with the high voltage transformer. Electrical: General Data Circuit: High Voltage Generator... Constant Potential High-Voltage Generator Grounding... Center-Grounded Nominal X-ray Tube Voltage (IEC60613:2010) kv Nominal Focal Spot Value (IEC60336:2005) Note) Nominal Anode Input Power (at 1.0s) (See rating Charts) W Nominal Radiographic Anode Input Power (IEC60613:2010) W Exposure Duty Cycle... 1:30 or more (Exposure time: interval time) Note) Test Condition: 70kV 3.2mA Mechanical: Dimensions: Overall Length... See dimensional outline Maximum Diameter... See dimensional outline Target: Anode Angle degrees Material... Tungsten Inherent Filtration... At least 1.0 mm Al X-ray Coverage... φ70 mm at SID 200 mm Weight... Approx. 100 g Cooling Method... Oil immersed (60 Max.) and convection oil cooling Tube Holding... Holding the glass envelope of the anode end and cathode end or the screw of the anode shank.. The information contained herein is presented only as a guide for the applications of our products. No Responsibility is assumed by TOSHIBA ELECTRON TUBES & DEVICES CO.,LTD.(TETD) for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TETD or others. The information contained herein may be changed without prior notice. It is therefore advisable to contact TETD before proceeding with the design of equipment incorporating this product.

2 Absolute Maximum and Minimum Ratings (At any time, these values must not be exceeded.) Maximum X-ray Tube Voltage (IEC60613:2010) kv Between Anode (or Cathode) and Ground kv Minimum X-ray Tube Voltage kv Maximum X-ray Tube Current (IEC60613:2010) (See rating Charts) ma Filament Characteristics: Maximum Filament Current A Filament Frequency Limits... DC or AC (Sine Wave) 0 ~ 20 khz Thermal Characteristics: Anode Heat Content J Maximum Anode Heat Dissipation W Maximum Radiographic Exposure Time s Environmental Limits Operating Limits (in dielectric oil): Oil Temperature ~ 60 Oil Pressure ~ 140 kpa Shipping and Storage Limits: Temperature ~ 70 Humidity ~ 90 % (No condensation) Atmospheric Pressure ~ 106 kpa - 2 -

3 Maximum Rating Charts (Absolute maximum rating charts) 12 Constant Potential High-Voltage Generator Nominal Focal Spot Value: kV TUBE CURRENT [ma] kV 70kV EXPOSURE TIME [s] Refer to IEC60613:2010 Emission & Filament Characteristics Constant Potential High-Voltage Generator Nominal Focal Spot Value: kV kV 3.5 TUBE CURRENT [ma] Ef 70kV FILAMENT VOLTAGE [V] FILAMENT CURRENT [A] Note1) This graph indicates typical characteristics. Note2) Refer to IEC60613:

4 Anode Heating / Cooling Curve J 100W HEAT STORAGE [J] COOLING 50W 500 HEATING TIME [s] - 4 -

5 Dimensional Outline Unit: mm 4.5 ±0.2 (Note) M4 12 Deep O 1.6 Depth 5 min. O ± ±5 CENTRAL X-RAY FOCAL SPOT 100 MIn. 8 Max. O31 Max. F C O 13 CENTRAL X-RAY C F F : Filament (Yellow) C : Cathode Note : Dimensions from an anode shank to a mounting hole

6 OVERSEAS SUBSIDIARIES AND AFFILIATES EU REPRESENTATIVE TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE DÜSSELDORF, GERMANY PHONE +49 (211) FAX +49 (211) For Sales & Technical Services, please contact the following representative: TOSHIBA ELECTRONICS EUROPE GMBH HANSAALLEE DÜSSELDORF, GERMANY PHONE +49 (211) FAX +49 (211) TOSHIBA AMERICA ELECTRONIC COMPONENTS, INC EAST LAKE COOK ROAD, SUITE 310 BUFFALO GROVE, ILLINOIS USA PHONE +1 (847) FAX +1 (847) TOSHIBA ELECTRON DEVICES & MATERIALS (SHANGHAI) CO., LTD. (TEMS) RM1606, SH-PLAZA, No.336, XIZANG ROAD (MIDDLE), SHANGHAI, , CHINA PHONE +86 (21) FAX +86 (21) (Product Development Engineering Department) 1385 SHIMOISHIGAMI, OTAWARA-SHI, TOCHIGI-KEN, , JAPAN PHONE: FAX: Toshiba Electron Tubes & Devices Co., Ltd. meets the Environmental Management System Standard, ISO Toshiba Electron Tubes & Devices Co., Ltd. meets internationally recognized Standards for Quality Management System ISO9001, ISO13485.

Product Information PI

Product Information PI Product Information PI ANALIX A-41 Series / A-41L Series The ANALIX A-41 (Short Body Type) / A-41L (Long Body Type) series, a water-cooled, grounded anode X-ray tube designed for X-ray diffractometry.

More information

Stationary Anode X-Ray Tube. General Data

Stationary Anode X-Ray Tube. General Data Technical Data TD TOSHIBA X-RAY TUBE D-041 D-041S D-041SB Stationary Anode X-Ray Tube Especially designed for dental radiography unit. Provided with an insulation cylinder (D-041S) and lead cylinder. (D-041SB)

More information

Product Information PI

Product Information PI Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE The TOSHIBA XH-183 housing is developed for use in surgical C-arm application. It provides ease for use at a nominal patient table height.

More information

Product Information PI

Product Information PI Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE E7869X High speed rotating anode X-ray tube assembly for high energy radiographic operations. For the purpose of general diagnostic X-ray

More information

Product Information PI

Product Information PI Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE E7252X E7252FX E7252GX High speed rotating anode X-ray tube assembly for high energy radiographic and cine-fluoroscopic operations. The

More information

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B Technical Data TD ROTANODE E7239X E7239FX E7239GX 0197 Rotating Anode X-Ray Tube Housing Assembly Rotating anode X-ray tube housing assembly for the purpose of general diagnostic X-ray procedures. Specially

More information

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I

Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Technical Data TD ROTANODE E7239X E7239FX E7239GX 197 Rotating Anode X-Ray Tube Housing Assembly Rotating anode X-ray tube housing assembly for the purpose of general diagnostic X-ray procedures. Specially

More information

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :

ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical : Technical Data TD ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic

More information

Rotating Anode X-Ray Tube Housing Assembly. General Data

Rotating Anode X-Ray Tube Housing Assembly. General Data Display Devices & Components Company TECHNICAL DATA ROTANODE TM E7252X Rotating Anode X-Ray Tube Housing Assembly! High speed rotating anode X-ray tube housing assembly for high energy radiographic and

More information

Product Information PI

Product Information PI Rotating node X-ray Tube ssembly Product Information PI ROTNODE E7884X E7884FX E7884GX Rotating anode X-ray tube assembly for high energy radiographic operations. The heavy anode is constructed with specially

More information

Rotating Anode X-ray Tube

Rotating Anode X-ray Tube Datasheet RADII KL74-1.0/2.0-125 Rotating Anode X-ray Tube Rotating anode X-ray tube for the purpose of general diagnostic X-ray procedures. Specially processed Tungsten faced molybdenum target of 74 mm

More information

Rotating Anode X-Ray Tube Housing Assembly. General Data

Rotating Anode X-Ray Tube Housing Assembly. General Data Technical Data TD ROTANODE E7252X E7252FX E7252GX 0197 Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic

More information

Rotating Anode X-ray Tube Assembly

Rotating Anode X-ray Tube Assembly RADII H18X H18Y Datasheet Rotating Anode X-ray Tube Assembly The tube unit is so constructed that an X-ray tube is sealed in a diagnostic type protective tube housing of electric shockproof, radiation

More information

Industrial X-ray Tube KL

Industrial X-ray Tube KL Description stationary anode x-ray tube is a highly popular and proven side window x-ray tube, which has focus 1.0 mm, is designed for non-destructive x-ray inspection. stationary anode x-ray tube can

More information

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85

CIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85 PD53-012 p Rotating Anode X-ray tube Assembly 0.3/0.8P32&0.6/1.2P32DK-85 GENERAL The Shimadzu 0.3/0.8P32DK-85 & 0.6/1.2P32DK-85, Rotating Anode X-ray tube assemblies are rated to 150kV and feature a 100mm

More information

Technical Data TD. X-Ray FLAT PANEL IMAGER FDX3543RP FEATURING: Active Area: 35(H) 43(V)cm (14 17 ) Excellent Sensitivity & Resolution

Technical Data TD. X-Ray FLAT PANEL IMAGER FDX3543RP FEATURING: Active Area: 35(H) 43(V)cm (14 17 ) Excellent Sensitivity & Resolution Technical Data TD X-Ray FLAT PANEL IMAGER FDX3543RP FEATURING: Active Area: 35(H) 43(V)cm (14 17 ) Excellent Sensitivity & Resolution Excellent Image Quality Excellent Reliability Excellent Sensitivity

More information

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F

PET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F Water Cooled Triode For Industrial RF Heating Drop in equivalent of BW1606J2F Output Power: 30 kw Anode voltage: 10 kv max Anode dissipation: 15 kw max Frequency up to 30 MHz Manufactured in India, in

More information

MXRP-160C. Product Description. Product Specifications

MXRP-160C. Product Description. Product Specifications MXRP-160C Product Description The MXRP-160C is an unipolar water-cooled tube assembly with integrated radiation protection. It comprises a single focal spot, a tungsten anode and a panoramic beam. The

More information

ARU-01CF Portable X-Ray NSN:

ARU-01CF Portable X-Ray NSN: ARU-01CF Portable X-Ray NSN: 6525-01-468-1672 COMMAND l AIR OPERATION & MAINTENANCE MANUAL Table of Contents Introduction................................................................3 Purpose.............................................................3

More information

The AMK 15-2 is a high-power metal/ceramic triode, intended for use in industrial generators for frequencies

The AMK 15-2 is a high-power metal/ceramic triode, intended for use in industrial generators for frequencies HIGH POWER TRIODE The is a high-power metal/ceramic triode, intended for use in industrial generators for frequencies up to 120 MHz and output power up to 63 kw in CW mode. Cooling is accomplished by water.

More information

Digital Panoramic X- Ray unit. Product Data

Digital Panoramic X- Ray unit. Product Data Digital Panoramic X- Ray unit Product Data Standard examination programs Standard panoramic: adult/child panoramic exam TMJ open/close mouth: 4 slices are taken in the same image (left/right condyle, open/close

More information

E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron

E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled two gap thyratron with ceramic envelope,

More information

ACS600, ACS800. Installation Guide

ACS600, ACS800. Installation Guide ACS600, ACS800 Installation Guide du/dt Filters AOCH0260-70 AOCH0400-70 NOCH0016-6x NOCH0030-6x NOCH0070-6x NOCH0120-6x NOCH0260-60 NOCH0400-60 NOCH0760-60 2003 ABB Oy. All Rights Reserved. 3AFE 58933368

More information

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F

PET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F Forced-Air Cooled Triode For Industrial RF Heating Drop in equivalent of BW1610F Output Power: 30 kw Anode voltage: 9 kv max Anode dissipation: 10 kw max Frequency up to 30 MHz Manufactured in India, in

More information

MG5223F S-Band Magnetron

MG5223F S-Band Magnetron MG5223F S-Band Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Fixed frequency pulse magnetron. Operating frequency... 3050 ± 10 MHz Typical peak output power...

More information

X-ray Tube and Generator Basic principles and construction

X-ray Tube and Generator Basic principles and construction X-ray Tube and Generator Basic principles and construction Dr Slavik Tabakov - Production of X-rays OBJECTIVES - X-ray tube construction - Anode - types, efficiency - X-ray tube working characteristics

More information

MG MW S-Band Magnetron

MG MW S-Band Magnetron MG8076 7.5 MW S-Band Magnetron This data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Peak power output...7.5 MW Centre frequency...2998 MHz Magnet...integral magnet or separate

More information

E2V Technologies MG5223F S-Band Magnetron

E2V Technologies MG5223F S-Band Magnetron E2V Technologies MG5223F S-Band Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Fixed frequency pulse magnetron. Operating frequency..... 3050 + 10 MHz Typical

More information

E2V Technologies CX1725, CX1725X Liquid Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons

E2V Technologies CX1725, CX1725X Liquid Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons E2V Technologies CX1725, CX1725X Liquid Cooled, Hollow Anode, Two-Gap Metal/Ceramic Thyratrons The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hollow anode, deuterium-filled

More information

Technical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension

Technical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension Technical data VARIABLE Height Bucky Table With Ceiling Suspension Model Variations CAMARGUE FH (Fixed Height) CAMARGUE FH Tomo CAMARGUE FH Ceiling suspension CAMARGUE VH (Variable Height) CAMARGUE VH

More information

GE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator

GE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator GE Sensing & Inspection Technologies The Titan E X-ray Generator Robust, Reliable and Highly Accurate Stationary X-ray Generators for the Widest Range of Applications. The Reference Class for X-ray generators

More information

Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0

Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0 Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL Version 1.0 Thank you for purchasing our HFX90V portable veterinary x-ray unit. We are confident that you will be pleased with the radiographs

More information

Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.

Abridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories. The data should be read in conjunction with the Magnetron Preamble and with British Standard BS9030: 1971 Abridged Data Mechanically tuned pulse magnetron intended primarily for linear accelerators. Frequency

More information

DENTAL RADIOGRAPHY KAMARUL AMIN BIN ABU BAKAR

DENTAL RADIOGRAPHY KAMARUL AMIN BIN ABU BAKAR DENTAL RADIOGRAPHY KAMARUL AMIN BIN ABDULLAH @ ABU BAKAR Components of the Dental X-Ray Machine Dental x-ray machines may vary somewhat in size and appearance, but all machines will have three primary

More information

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION

VGM Series. 100 & 60 W, Efficient, CV Class 2 LED Drivers for Signage Applications ORDERING INFORMATION Nominal Input Voltage Max. Output Power Nominal Output Voltage Max. Output Current 120/277 Vac 12, 24, Vdc 5, 3.92 A Efficiency up to 90% typical Max. Case Temperature 100 C (measured at the hot spot)

More information

MG7095 Tunable S-Band Magnetron

MG7095 Tunable S-Band Magnetron MG7095 Tunable S-Band Magnetron The data should be read in conjunction with the Magnetron Preamble and with British Standard BS9030 : 1971. ABRIDGED DATA Mechanically tuned pulse magnetron intended primarily

More information

YD1195/8913 YD1197/8937 RF Power Triodes

YD1195/8913 YD1197/8937 RF Power Triodes YD1195/8913 YD1197/8937 RF Power Triodes The YD1195/8913 and YD1197/8937 are RF power triodes in metal-ceramic construction intended for use as industrial oscillators. The YD1195 is forced-air cooled.

More information

MKP1V120 Series. Sidac High Voltage. Bidirectional Triggers 0.9 AMPERES RMS VOLTS

MKP1V120 Series. Sidac High Voltage. Bidirectional Triggers 0.9 AMPERES RMS VOLTS MKP112 Series Sidac High oltage Bidirectional Triggers Bidirectional devices designed for direct interface with the ac power line. Upon reaching the breakover voltage in each direction, the device switches

More information

CR02AM-8. Thyristor. Low Power Use. Features. Outline. Applications. Maximum Ratings. REJ03G Rev.1.00 Aug Planar Passivation Type

CR02AM-8. Thyristor. Low Power Use. Features. Outline. Applications. Maximum Ratings. REJ03G Rev.1.00 Aug Planar Passivation Type CRAM-8 Thyristor Low Power Use REJG1-1 Rev.1. Aug..4 Features I T (AV) :. A V DRM : 4 V I GT : 1 µa Planar Passivation Type Outline TO-9 1 1. Cathode. Anode. Gate 1 Applications Solid state relay, leakage

More information

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE / INCH-POUND MIL-PRF-1/1756B 18 October 2002 SUPERSEDING MIL-PRF-1/1756A 22 August 1997 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE 8964 1/ This specification is approved

More information

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage

X-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage X-rays Ouch! 1 X-rays X-rays are produced when electrons are accelerated and collide with a target Bremsstrahlung x-rays Characteristic x-rays X-rays are sometimes characterized by the generating voltage

More information

World-Class Accuracy & Measurement Range (40 Conventional Models)

World-Class Accuracy & Measurement Range (40 Conventional Models) AC/DC CURRENT SENSOR CT6904 Ultra-High Performance AC/DC Current Sensor World-Class Accuracy & Measurement Range (40 Conventional Models) 500 A (rms) Rated for measurement of large currents 4 MHz (±3 db)

More information

GE Inspection Technologies. The ISOVOLT Titan E X-ray Generator

GE Inspection Technologies. The ISOVOLT Titan E X-ray Generator GE Inspection Technologies The Titan E X-ray Generator Robust, Reliable and Highly Accurate Stationary X-ray Generators for the Widest Range of Applications. The Reference Class for X-ray generators is

More information

MILADY. Product Data. Page 1 of 8

MILADY. Product Data. Page 1 of 8 Page 1 of 8 The MILADY Mammographic Unit offers the best quality-to-price ratio to our customers worldwide. The unit advanced technology together with the application of industrial production standards,

More information

1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013).

1. Carlton, Richard R., and Arlene M. Adler. Principles of Radiographic Imaging: An Art and a Science, 5th edition (2013). CODE: RADT 151 INSTITUTE: Health Science TITLE: Radiographic Exposure DEPARTMENT: Radiologic Technology COURSE DESCRIPTION: This course covers the principles of radiographic exposure selection and manipulation

More information

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over a lifetime Breast cancer screening programs rely on

More information

TIC116 SERIES SILICON CONTROLLED RECTIFIERS

TIC116 SERIES SILICON CONTROLLED RECTIFIERS TIC6 SERIES Copyright 997, Power Innovations Limited, UK APRIL 97 - REVISED MARCH 997 8 A Continuous On-State Current 8 A Surge-Current Glass Passivated Wafer 4 V to 8 V Off-State Voltage Max I GT of ma

More information

HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW

HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW The high frequency X-Ray monoblock consists of an inverter and oil-filled tank which houses the high voltage transformer and tube. It has been designed and developed

More information

ic-sd85 olga SD2C3 Infrared LED

ic-sd85 olga SD2C3 Infrared LED Rev C2, Page 1/6 FEATURES Emission peak at 850 nm matched to silicon sensors Broad irradiance pattern (lambertian profile) High temperature range -40 to 125 C High optical output power Fast switching speed

More information

TIC106 SERIES SILICON CONTROLLED RECTIFIERS

TIC106 SERIES SILICON CONTROLLED RECTIFIERS TIC6 SERIES Copyright 997, Power Innovations Limited, UK APRIL 97 - REVISED MARCH 997 5 A Continuous On-State Current 3 A Surge-Current Glass Passivated Wafer 4 V to 8 V Off-State Voltage Max I GT of 2

More information

MG5193 Tunable S-Band Magnetron

MG5193 Tunable S-Band Magnetron MG5193 Tunable S-Band Magnetron The data should be read in conjunction with the Magnetron Preamble and with British Standard BS9030 : 1971. ABRIDGED DATA Mechanically tuned pulse magnetron intended primarily

More information

M5028 Precision Tuned Magnetron

M5028 Precision Tuned Magnetron M5028 Precision Tuned Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Precision tuned pulse magnetron for linear accelerators. The tuning drive will mechanically

More information

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

X-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent X-band Magnetron GENERAL DESCRIPTION MX7637 is a tunable X-band pulsed type magnetron intended primarily for linear accelerator. It is cooled with water and has a UG51/U (WR112) output coupling. It is

More information

X-ray Tube and Generator Basic principles and construction

X-ray Tube and Generator Basic principles and construction X-ray Tube and Generator Basic principles and construction Dr Slavik Tabakov - Production of X-rays and Patient Dose OBJECTIVES - X-ray tube construction - Anode - types, efficiency - Classical X-ray generator

More information

FFSH5065A. Silicon Carbide Schottky Diode 650 V, 50 A

FFSH5065A. Silicon Carbide Schottky Diode 650 V, 50 A Silicon Carbide Schottky Diode 65 V, 5 A Description Silicon Carbide (SiC) Schottky Diodes use a completely new technology that provides superior switching performance and higher reliability compared to

More information

HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW

HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW The high frequency X-Ray monoblock consists of an inverter and oil-filled tank which houses the high voltage transformer and tube. It has been designed and developed

More information

GE AMX 4+ Portable X-Ray

GE AMX 4+ Portable X-Ray GE AMX 4+ Portable X-Ray Typical Manufacturer s Picture GE Healthcare s AMX-4+ analog X-ray system provides high-performance in a compact, easy-to-maneuver package. The rotating arm and tube simplify positioning

More information

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE /

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE / INCH-POUND MIL-PRF-1/1757B 18 October 2002 SUPERSEDING MIL-PRF-1/1757A(NAVY) 5 September 1997 PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE 8965 1/ This specification is

More information

SA5.0A Series 500 Watt Peak Power MiniMOSORB Zener Transient Voltage Suppressors

SA5.0A Series 500 Watt Peak Power MiniMOSORB Zener Transient Voltage Suppressors 5 Watt Peak Power MiniMOSORB Zener Transient Voltage Suppressors Unidirectional The SA5.A series is designed to protect voltage sensitive components from high voltage, high energy transients. They have

More information

E2V Technologies M5187F X-Band Magnetron

E2V Technologies M5187F X-Band Magnetron E2V Technologies M5187F X-Band Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Fixed frequency pulse magnetron. It is a direct replacement for the M515 but offers

More information

QED223 Plastic Infrared Light Emitting Diode

QED223 Plastic Infrared Light Emitting Diode QED223 Plastic Infrared Light Emitting Diode Features λ = 880nm Chip material = AlGaAs Package type: T-1 3/4 (5mm lens diameter) Matched photosensor: QSD123/QSD124 Medium wide emission angle, 30 High output

More information

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water S-band Magnetron GENERAL DESCRIPTION is a mechanical tuned pulsed type S-band magnetron intended primarily for linear accelerator. It is water cooled and has circle waveguide output type. It is designed

More information

5 W XENON FLASH LAMP MODULES

5 W XENON FLASH LAMP MODULES LAMP W XENON FLASH LAMP MODULES : L/L series (side-on type) : L/L series (head-on type) : L/L series (high output type) : L (SMA fiber adapter type) : L/L series (high precision type) : L/L series (silent

More information

S24SP12004 series 40W Single Output DC/DC Converter

S24SP12004 series 40W Single Output DC/DC Converter FEATURES Efficiency up to 92.8% Wide input range, 9V-36V Package with Industry Standard Pinout Package Dimension: Without heat sink 5.8 x25.4 x1.5mm (2. x1. x.41 ) With heat sink 5.8 x25.4 x17.5mm (2.

More information

S24SP05012 series 60W Single Output DC/DC Converter

S24SP05012 series 60W Single Output DC/DC Converter Model List Model Number S24SP05012 Input Voltage (Range) Output Voltage Output Current Input Current (typ input voltage) Load Regulation Maxcapacitive Load (Cap ESR>=10mohm;Full Efficiency load;5%overshoot

More information

S24SP24003 series 60W Single Output DC/DC Converter

S24SP24003 series 60W Single Output DC/DC Converter FEATURES Efficiency up to 93% Wide input range, 9V-36V Package with Industry Standard Pinout Package Dimension: Without heat sink 5.8 x25.4 x1.5mm (2. x1. x.41 ) With heat sink 5.8 x25.4 x17.5mm (2. x1.

More information

MobileDaRt Evolution MX8 Version

MobileDaRt Evolution MX8 Version PD504-021 Mobile X-ray System MobileDaRt Evolution MX8 Version MX8c type GENERAL The MobileDaRt Evolution is a general-purpose mobile digital X-ray system, which can be freely moved throughout a hospital

More information

Disclosure to Promote the Right To Information

Disclosure to Promote the Right To Information इ टरन ट म नक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information

More information

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943 INCH-POUND PERFORMANCE SPECIFICATION SHEET MIL-PRF-1/1734C 17 April 2014 SUPERSEDING MIL-PRF-1/1734B 11 March 1998 ELECTRON TUBE, MAGNETRON TYPE 8943 This specification is approved for use by all Departments

More information

BCA 9SK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode

BCA 9SK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode ELECTRICAL CHARACTERISTICS Voltage 230 Vac ±10% monophase standard 105 / 115 / 125 / 220 / 240 Vac ±10% monophase on request Frequency 50 Hz standard 60 Hz on request Absorbed current on Stationary 4.5

More information

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent

X band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent X band Magnetron GENERAL DESCRIPTION MX7621 is a tunable X-band pulsed type magnetron intended primarily for linear accelerator. It is cooled with water and has a UG51/U (WR112) output coupling. It is

More information

TECHNICAL INFORMATION

TECHNICAL INFORMATION TECHNICAL INFORMATION RIPPLE RATING OF TANTALUM CHIP CAPACITORS by R.W. Franklin AVX Limited Brixham Road, Paignton Devon, England Abstract: The ripple current and voltage limits of tantalum chip capacitors

More information

E2V Technologies MG6028 Fast Tuned Magnetron

E2V Technologies MG6028 Fast Tuned Magnetron E2V Technologies MG6028 Fast Tuned Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Fast tuned pulse magnetron for linear accelerators. The tuning drive will

More information

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document

USER MANUAL. Maxwell Technologies Ultracapacitor Energy Storage Modules. Models: BMOD0058 E016 B02 BMOD0006 E160 B02. Document USER MANUAL Maxwell Technologies Ultracapacitor Energy Storage Modules Models: BMOD0058 E016 B02 BMOD0006 E160 B02 Document 3000200.1 Notice: The products described herein are covered by one or more of

More information

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX. The premium intraoral X-ray unit... ProX Intraoral X-ray PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX. This advanced unit provides

More information

P R E S E N T E D B Y. K A M A R U L A M I N A B D U L L A H Dip. MED. IMG., BSc. MED. IMG. (UiTM)

P R E S E N T E D B Y. K A M A R U L A M I N A B D U L L A H Dip. MED. IMG., BSc. MED. IMG. (UiTM) + - P R E S E N T E D B Y K A M A R U L A M I N A B D U L L A H Dip. MED. IMG., BSc. MED. IMG. (UiTM) 1 I N T R O D U C T I O N : An x-ray generator is a device that Supplies electrical power to x-ray

More information

URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER

URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER Patent Protection RoHS FEATURES Efficiency up to 88% Ultra wide input voltage range(4:1) Good

More information

Svetlana 4CX7500A Radial Beam Power Tetrode

Svetlana 4CX7500A Radial Beam Power Tetrode Svetlana CX7500A Radial Beam Power Tetrode T he Svetlana CX7500A is designed for audio and radio frequency applications. The Svetlana CX7500A has a directly-heated thoriated tungsten mesh filament for

More information

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by

SPECIFICATION. Kilovoltage X-ray calibration system for protection and diagnostic level dosimetry. Prepared by SPECIFICATION Kilovoltage X-ray Prepared by Igor Gomola, Technical Officer, Project ECU6023, Date 2015-Oct-06 Revision Date Status Comments 0.1 2015-Oct-06 Draft Igor Gomola Page 1 of 12 1. Scope This

More information

2014 CINDE Toronto Portable X-ray & X-Ray Production

2014 CINDE Toronto Portable X-ray & X-Ray Production 2014 CINDE Toronto Portable X-ray & X-Ray Production Nils Hase, Business Development Manager Portable X-Ray business unit Copenhagen and USA Technology with Passion 3 COMET Headquarters Flamatt Switzerland

More information

HY-3002/5948A-Replacement Hydrogen Filled Triode Thyratron

HY-3002/5948A-Replacement Hydrogen Filled Triode Thyratron HY-3002/5948A-Replacement Description The HY-3002 is a hydrogen-filled, triode thyratron. The hydrogen gas fill facilitates reliable operation at a moderately-high voltage and very high pulse repetition

More information

Low Capacitance Transient Voltage Suppressors / ESD Protectors CM QG/D. Features

Low Capacitance Transient Voltage Suppressors / ESD Protectors CM QG/D. Features Low Capacitance Transient Voltage Suppressors / ESD Protectors CM1250-04QG Features Low I/O capacitance at 5pF at 0V In-system ESD protection to ±8kV contact discharge, per the IEC 61000-4-2 international

More information

TIC106 SERIES SILICON CONTROLLED RECTIFIERS

TIC106 SERIES SILICON CONTROLLED RECTIFIERS TIC06 SERIES Copyright 999, Power Innovations Limited, UK APRIL 97 - REVISED JULY 2000 5 A Continuous On-State Current 30 A Surge-Current Glass Passivated Wafer 400 V to 800 V Off-State Voltage Max I GT

More information

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION

VIM Series. 90 & 60 W, Efficient, CV Class 2 LED Drivers ORDERING INFORMATION 060W-12 100W-24 Nominal Input Voltage 90 &, Efficient, CV Class 2 Max. Output Power Nominal Output Voltage Max. Output Current 120 & 277 Vac 12, 24 Vdc 5, 3.75 A Efficiency up to 90% typical Max. Case

More information

ACULED DYO TM Design-Your-Own Guide

ACULED DYO TM Design-Your-Own Guide CUSTOM DESIGN GUIDE Lighting Solutions ACULED DYO TM DesignYourOwn Guide Overview Excelitas ACULED DYO TM gives customers the flexibility to DesignYour Own fourchip LED configuration to best suit specific

More information

XRC X-Ray Calibration System

XRC X-Ray Calibration System XRC X-Ray Calibration System Technical Description Contents 1. Equipment overview 2. X-ray Beam Specifications 3. The Control Console 4. Radiation Safety 5. Filters 6. X-ray Generator & Heat Exchange Equipment

More information

SMF5.0AT1G Series, SZSMF5.0AT1G Series. 200 W Transient Voltage Suppressor SOD-123 Flat Lead Package

SMF5.0AT1G Series, SZSMF5.0AT1G Series. 200 W Transient Voltage Suppressor SOD-123 Flat Lead Package SMF5.AT1G Series, SZSMF5.AT1G Series 2 W Transient Voltage Suppressor SOD-123 Flat Lead Package The SMF5.AT1G Series is designed to protect voltage sensitive components from high voltage, high energy transients.

More information

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah

X-RAY IMAGING EE 472 F2017. Prof. Yasser Mostafa Kadah X-RAY IMAGING EE 472 F2017 Prof. Yasser Mostafa Kadah www.k-space.org Recommended Textbook Stewart C. Bushong, Radiologic Science for Technologists: Physics, Biology, and Protection, 10 th ed., Mosby,

More information

30KP SERIES. Features. Mechanical Data. Maximum Ratings and Electrical A =25 C unless otherwise specified

30KP SERIES. Features. Mechanical Data. Maximum Ratings and Electrical A =25 C unless otherwise specified 3KP SERIES 3W TRANSIENT VOLTAGE SUPPRESSOR Pb Features Glass Passivated Die Construction 3W Peak Pulse Power Dissipation 8V 88V Standoff Voltage A B A Uni- and Versions Available Excellent Clamping Voltage

More information

Ceramic Disc Capacitors Class 2, 500 V DC, 1 kv DC, General Purpose

Ceramic Disc Capacitors Class 2, 500 V DC, 1 kv DC, General Purpose Ceramic Disc Capacitors Class 2, 500 V DC, 1 kv DC, General Purpose FEATURES High capacitance in small size Kinked (preferred) or straight leads Compliant to RoHS Directive 2011/65/EU APPLICATIONS Bypassing

More information

VLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers

VLM60/40 Series. 60 & 40 W, Efficient, Compact Constant Voltage Class 2 LED Drivers /40 Nominal Input Voltage 120/277 Vac, 220 to 240 Vac Max. Output Power Nominal Output Voltage Max. Output Current 12, 24, 48 Vdc 5, 2.5, 1.25 A Efficiency up to 90% typical Max. Case Temperature 90 C

More information

URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER

URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER Patent Protection RoHS FEATURES Efficiency up to 88% Ultra wide input voltage range(4:1) Good

More information

Performance Specifications

Performance Specifications TX-502 Temperature Compensated Crystal Oscillator High Precision TX-502 Features High Precision TCXO OCXO Replacement OCXO Temperature Performance Low power consumption Tight Tolerances Frequency range

More information

ASMB-KTF0-0A306-DS100

ASMB-KTF0-0A306-DS100 Data Sheet ASMB-KTF0-0A306 Overview The KTF0 is a series of tricolor LEDs in a PLCC-4 package. The package is (2.2 x 2.0) mm, and it is designed specifically for a small pitch display. The black outer

More information

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features

PRODUCT DATA. Sound Intensity Calibrator Type Uses and Features PRODUCT DATA Sound Intensity Calibrator Type 4297 Sound Intensity Calibrator Type 4297 is used for on site sound pressure calibration and pressure residual intensity index verification. Its most important

More information

Electrical Specifications

Electrical Specifications POWER Data Sheet NFS110 Medical Series Single and quad output Total Power: 80-110 W Input Voltage: 100-240Vac 127-357 Vdc # of Outputs: Single, quad Special Features 7.0 x 4.25 x 1.8 inch package Medical,

More information

Low voltage products in high altitudes

Low voltage products in high altitudes WHITE PAPER Low voltage products in high altitudes Information and technical guidance for applications above 2000 m sea level This white paper provides information including technical guidance for high

More information

BAV103 High Voltage, General Purpose Diode

BAV103 High Voltage, General Purpose Diode BAV3 High Voltage, General Purpose Diode Cathode Band SOD80 Description A general purpose diode that couples high forward conductance fast swiching speed and high blocking voltages in a glass leadless

More information

ic-tl46 TO46-2L1 Blue LED

ic-tl46 TO46-2L1 Blue LED Rev B1, Page 1/6 FEATURES Emission peak at 460 nm Optimized irradiance pattern Temperature range -40 C to 100 C High efficiency LED chip Fast switching speed TO-46 package for flexible mounting Option:

More information

SBT700-06RH. Schottky Barrier Diode 60V, 70A, VF; 0.66V Dual To-3PF-3L Cathode Common

SBT700-06RH. Schottky Barrier Diode 60V, 70A, VF; 0.66V Dual To-3PF-3L Cathode Common Ordering number : ENA16A SBT-6RH Schottky Barrier Diode 6V, A, VF;.66V Dual To-PF-L Cathode Common http://onsemi.com Applications High frequency rectification (switching regulators, converters, choppers)

More information