Product Information PI
|
|
- Alexina Martin
- 6 years ago
- Views:
Transcription
1 Rotating node X-ray Tube ssembly Product Information PI ROTNODE E7884X E7884FX E7884GX Rotating anode X-ray tube assembly for high energy radiographic operations. The heavy anode is constructed with specially processed rhenium-tungsten faced molybdenum target which is 74 mm diameter and has an improved coating to increase thermal emissivity. These tubes have foci 1.2 and.6, and are available for a maximum tube voltage 15 kv. ccommodated with IEC6526 type high-voltage cable receptacles. General Data IEC Classification (IEC661-1:25)... Class Ⅰ ME EQUIPMENT Electrical: Circuit: High Voltage Generator... Constant Potential High-Voltage Generator Grounding... Center-grounded Nominal X-ray Tube Voltage (IEC6613:21): Radiographic kv Nominal Focal Spot Value (IEC6336:25): Large Focus Small Focus....6 Nominal node Input Power (at.1s): 6 Hz 5 Hz Large Focus kw 5 kw Small Focus kw 2 kw Nominal Radiographic node Input Power (IEC6613:21): 6 Hz 5 Hz Large Focus kw 44 kw Small Focus kw 2 kw The information contained herein is presented only as a guide for the application of our products. No responsibility is assumed by Toshiba Electron Tubes & Devices Co., Ltd. (TETD) for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TETD or others. The information contained herein may be changed without prior notice. It is therefore, advisable to contact to TETD before processing with the design of equipment incorporating this product.
2 Motor Ratings: Stator: XS-L Starting Running Driven Frequency [Hz] 5/6 5/6 Input Power [W] Voltage 1) 3) [V] 13 4 Current 2) [] Min. Speed Up 4) [s].8 - Capacitor [µf] Note: 1) pplied voltage between common and main terminal. 2) Common current. 3) The every applied voltage must be never exceeded 11% of the above specification. 4) The speed-up time is allowed up to 11% of the above specification. node Speed: 6 Hz... Minimum 32 min -1 5 Hz... Minimum 27 min -1 Stator Resistance: Common-Main Winding Ω Common-uxiliary Winding Ω Resistance Between Housing and Low Voltage Terminals... Minimum 2 MΩ Normal Operating Range of the Housing Temperature ~ 75 Mode of Operation... Intermittent Mechanical: Dimensions... See dimensional outline Overall Length mm Maximum Diameter mm Target: node ngle degrees Diameter mm Construction... Rhenium-Tungsten faced Molybdenum Filtration: Permanent Filtration....9 mm l / 75 kv IEC6522:1999 vailable dditional Filter combination ( mm)... Maximum 2.4 mm l / 75 kv Radiation Protection (In accordance with IEC :28): Leakage Technique Factor kv, 3.4 m X-ray Coverage mm at SID 1 mm Weight (pprox.) kg High Voltage Receptacle... To meet requirements of IEC6526 Corrigendum1:21 Cooling Method... Natural or forced air Tube Housing Model Number: E7884X... XH-121 E7884FX... XH-126 E7884GX... XH
3 bsolute Maximum and Minimum Ratings (t any time, these values must not be exceeded) Maximum X-ray Tube Voltage (IEC6613:21): Radiographic kv Between node (or Cathode) and Ground kv Minimum X-ray Tube Voltage... 4 kv Maximum X-ray Tube Current (IEC6613:21)... See rating charts Large Focus... 7 m Small Focus... 3 m Maximum Filament Current: Large Focus Small Focus Filament Voltage: Large Focus (t maximum filament current 5.4 ) ~ 16.1 V Small Focus (t maximum filament current 5.2 ) ~ 9.2 V Filament Frequency Limits... ~ 25 khz Continuous node Input Power (IEC6613:21) W (2 HU/s) Thermal Characteristics: node Heat Content kj (3 khu) Maximum node Heat Dissipation W (1226 HU/s) X-ray Tube ssembly Heat Content... 9 kj (125 khu) Nominal Continuous Input Power (IEC6613:21): Without ir-circulator W (15 khu/min) Environmental Limits Operating Limits: Temperature... 1 ~ 4 Humidity... 3 ~ 85 % (No condensation) tmospheric Pressure... 7 ~ 16 kpa Shipping and Storage Limits: Temperature ~ 7 Humidity... 2 ~ 9 % (No condensation) tmospheric Pressure... 5 ~ 16 kpa - 3 -
4 Maximum Rating Charts (bsolute Maximum Rating Charts) Conditions: Tube Voltage Constant potential high-voltage generator Stator Power Frequency 6 Hz Nominal Focal Spot Value: 1.2 Nominal Focal Spot Value:.6 TUBE CURRENT [m] kV 9kV 1kV 11kV 125kV 15kV 7kV6kV 5kV 4kV TUBE CURRENT [m] kV 9kV 1kV 11kV 125kV 15kV 7kV 6kV 5kV 4kV EXPOSURE TIME [s].1 Refer to IEC6613: EXPOSURE TIME [s] TUBE CURRENT [m] kV 9kV 1kV 11kV 125kV 15kV Conditions: Tube Voltage Constant potential high-voltage generator Stator Power Frequency 5 Hz Nominal Focal Spot Value: 1.2 Nominal Focal Spot Value:.6 7kV 6kV 5kV 4kV TUBE CURRENT [m] kV 9kV 1kV 11kV 125kV 15kV 7kV 6kV 5kV 4kV EXPOSURE TIME [s].1 Refer to IEC6613: EXPOSURE TIME [s] - 4 -
5 Emission & Filament Characteristics Constant potential high-voltage generator Nominal Focal Spot Value: TUBE CURRENT [m] Ef 4kV 5kV 6kV 8kV 1kV kV FILMENT VOLTGE [V] FILMENT CURRENT [] Note1) For Reference Only Note2) Refer to IEC6613:21 Nominal Focal Spot Value: TUBE CURRENT [m] Ef kV 1kV 8kV 6kV 5kV 4kV FILMENT VOLTGE [V] FILMENT CURRENT [] Note1) For Reference Only Note2) Refer to IEC6613:21-5 -
6 Thermal Characteristics X-ray Tube ssembly Heating / Cooling Curve COOLING 18W HET STORGE [kj] HETING TIME [min] 21 2 node Heating / Cooling Curve HET STORGE [kj] HETING COOLING 142W TIME [min] The heating curves are showing example of average input power to anode in operation
7 Dimensional Outline of E7884X Unit: mm φ14 NODE 4-M6 8 DEEP φ92 φ CENTRL RY ND REFERENCE XIS 12 4-M5 8 DEEP L S CTHODE C M63.5, P=1.27 TERMINL CONNECTIONS NC NC NC E C1 M NC FOCL SPOT φ69 TEMPERTURE RELY (NORMLLY CLOSED) ET Note) Do not connect terminal No.1 and No.5 or 6 in series circuit. CTHODE TERMINL C : COMMON L : LRGE FOCUS S : SMLL FOCUS B CENTER OF FOCL SPOT TERMINL CONNECTIONS C1 : COMMON M : MIN WINDING OF THE STTOR : UX. WINDING OF THE STTOR NC : NON-CONNECTION ET : ERTH TERMINL -1.5mm 1.5mm -1.5mm B 1.5mm : CENTRL X-RY NODE & CTHODE TERMINL : IEC6526 TYPE - 7 -
8 Dimensional Outline of E7884FX Unit: mm φ14 NODE CTHODE L S CENTRL RY ND REFERENCE XIS φ92 φ M6 8 DEEP M5 8 DEEP C 81 9 TERMINL CONNECTIONS E 2-M63.5, P= NCNC NC C1 M NC φ69 81 TEMPERTURE RELY (NORMLLY CLOSED) ET Note) Do not connect terminal No.1 and No.5 or 6 in series circuit. FOCL SPOT CTHODE TERMINL C : COMMON L : LRGE FOCUS S : SMLL FOCUS B CENTER OF FOCL SPOT TERMINL CONNECTIONS C1 M NC ET : COMMON : MIN WINDING OF THE STTOR : UX. WINDING OF THE STTOR : NON-CONNECTION : ERTH TERMINL -1.5mm 1.5mm -1.5mm B 1.5mm : CENTRL X-RY NODE & CTHODE TERMINL : IEC6526 TYPE - 8 -
9 Dimensional Outline of E7884GX Unit: mm 4-M5 8 DEEP M6 8 DEEP 9 9 CENTRL RY ND REFERENCE XIS 12 φ14 φ L S NODE CTHODE C CENTER OF FOCL SPOT M63.5, P=1.27 TERMINL CONNECTIONS E B -1.5mm 1.5mm -1.5mm B 1.5mm φ69 NCNC NC C1 M TEMPERTURE RELY (NORMLLY CLOSED) NC ET 53 FOCL SPOT Note) Do not connect terminal No.1 and No.5 or 6 in series circuit. EXPLNTION OF SYMBOLS CTHODE TERMINL C : COMMON L : LRGE FOCUS S : SMLL FOCUS TERMINL CONNECTIONS C1 M NC ET : COMMON : MIN WINDING OF THE STTOR : UX. WINDING OF THE STTOR : NON-CONNECTION : ERTH TERMINL : CENTRL X-RY NODE & CTHODE TERMINL : IEC6526 TYPE - 9 -
10 Marketing Engineering Group, Sales Department 1385,Shimoishigami,Otawara-shi,Tochigi ,Japan Tel: Fax: The head office of Toshiba Electron Tubes & Devices Co., Ltd. has been certified to meet all the requirements of Environmental Management System ISO141. Toshiba Electron Tubes & Devices Co., Ltd. has been certified to meet all the requirements of Quality Management Systems ISO91 and ISO Product scope is referred to the following URL. PE-E7884X/FX/GX 217-2
Product Information PI
Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE E7252X E7252FX E7252GX High speed rotating anode X-ray tube assembly for high energy radiographic and cine-fluoroscopic operations. The
More informationProduct Information PI
Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE E7869X High speed rotating anode X-ray tube assembly for high energy radiographic operations. For the purpose of general diagnostic X-ray
More informationProduct Information PI
Rotating Anode X-ray Tube Assembly Product Information PI ROTANODE The TOSHIBA XH-183 housing is developed for use in surgical C-arm application. It provides ease for use at a nominal patient table height.
More informationRotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I
Technical Data TD ROTANODE E7239X E7239FX E7239GX 197 Rotating Anode X-Ray Tube Housing Assembly Rotating anode X-ray tube housing assembly for the purpose of general diagnostic X-ray procedures. Specially
More informationROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Electrical :
Technical Data TD ROTANODE TM E7252X E7252FX E7252GX Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic
More informationRotating Anode X-Ray Tube Housing Assembly. General Data. IEC Classification... Class I Type B
Technical Data TD ROTANODE E7239X E7239FX E7239GX 0197 Rotating Anode X-Ray Tube Housing Assembly Rotating anode X-ray tube housing assembly for the purpose of general diagnostic X-ray procedures. Specially
More informationRotating Anode X-Ray Tube Housing Assembly. General Data
Display Devices & Components Company TECHNICAL DATA ROTANODE TM E7252X Rotating Anode X-Ray Tube Housing Assembly! High speed rotating anode X-ray tube housing assembly for high energy radiographic and
More informationProduct Information PI
Product Information PI TOSHIBA X-RAY TUBE D-045 Stationary Anode X-ray Tube Especially designed for dental radiography unit. This tube has focus 0.4, and is available for maximum tube voltage 70 kv. Installed
More informationRotating Anode X-ray Tube Assembly
RADII H18X H18Y Datasheet Rotating Anode X-ray Tube Assembly The tube unit is so constructed that an X-ray tube is sealed in a diagnostic type protective tube housing of electric shockproof, radiation
More informationRotating Anode X-Ray Tube Housing Assembly. General Data
Technical Data TD ROTANODE E7252X E7252FX E7252GX 0197 Rotating Anode X-Ray Tube Housing Assembly High speed rotating anode X-ray tube housing assembly for high energy radiographic and cine-fluoroscopic
More informationRotating Anode X-ray Tube
Datasheet RADII KL74-1.0/2.0-125 Rotating Anode X-ray Tube Rotating anode X-ray tube for the purpose of general diagnostic X-ray procedures. Specially processed Tungsten faced molybdenum target of 74 mm
More informationCIRCLEX 0.3/0.8P324&0.6/1.2P324DK-85
PD53-012 p Rotating Anode X-ray tube Assembly 0.3/0.8P32&0.6/1.2P32DK-85 GENERAL The Shimadzu 0.3/0.8P32DK-85 & 0.6/1.2P32DK-85, Rotating Anode X-ray tube assemblies are rated to 150kV and feature a 100mm
More informationProduct Information PI
Product Information PI ANALIX A-41 Series / A-41L Series The ANALIX A-41 (Short Body Type) / A-41L (Long Body Type) series, a water-cooled, grounded anode X-ray tube designed for X-ray diffractometry.
More informationStationary Anode X-Ray Tube. General Data
Technical Data TD TOSHIBA X-RAY TUBE D-041 D-041S D-041SB Stationary Anode X-Ray Tube Especially designed for dental radiography unit. Provided with an insulation cylinder (D-041S) and lead cylinder. (D-041SB)
More informationTechnical data CAMARGUE CS-VH50/300. VARIABLE Height Bucky Table With Ceiling Suspension
Technical data VARIABLE Height Bucky Table With Ceiling Suspension Model Variations CAMARGUE FH (Fixed Height) CAMARGUE FH Tomo CAMARGUE FH Ceiling suspension CAMARGUE VH (Variable Height) CAMARGUE VH
More informationIndustrial X-ray Tube KL
Description stationary anode x-ray tube is a highly popular and proven side window x-ray tube, which has focus 1.0 mm, is designed for non-destructive x-ray inspection. stationary anode x-ray tube can
More informationCorsix R 32 Accu PRODUCT DATA
PRODUCT DATA Product data Rev. 1 (April 2011) Page Description and Configurations 3 Technical Features 4 Radiological characteristics 4 Operating characteristics 5 Mechanical characteristics 6 Size and
More informationBCA 9SK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode
ELECTRICAL CHARACTERISTICS Voltage 230 Vac ±10% monophase standard 105 / 115 / 125 / 220 / 240 Vac ±10% monophase on request Frequency 50 Hz standard 60 Hz on request Absorbed current on Stationary 4.5
More informationDigital Panoramic X- Ray unit. Product Data
Digital Panoramic X- Ray unit Product Data Standard examination programs Standard panoramic: adult/child panoramic exam TMJ open/close mouth: 4 slices are taken in the same image (left/right condyle, open/close
More informationMXRP-160C. Product Description. Product Specifications
MXRP-160C Product Description The MXRP-160C is an unipolar water-cooled tube assembly with integrated radiation protection. It comprises a single focal spot, a tungsten anode and a panoramic beam. The
More informationBCA 9RK. 60 Hz on request Absorbed current on Stationary Vac and Vac in fluoro mode
ELECTRICAL CHARACTERISTICS RADIOLOGICAL DATA MONOBLOC Voltage 230 Vac ±10% monophase standard 105 / 115 / 125 / 220 / 240 Vac ±10% monophase on request Frequency 50 Hz standard 60 Hz on request Absorbed
More informationPET1606J2F. Pilani Electron Tubes & Devices Pvt. Ltd. Water Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1606J2F
Water Cooled Triode For Industrial RF Heating Drop in equivalent of BW1606J2F Output Power: 30 kw Anode voltage: 10 kv max Anode dissipation: 15 kw max Frequency up to 30 MHz Manufactured in India, in
More informationYD1195/8913 YD1197/8937 RF Power Triodes
YD1195/8913 YD1197/8937 RF Power Triodes The YD1195/8913 and YD1197/8937 are RF power triodes in metal-ceramic construction intended for use as industrial oscillators. The YD1195 is forced-air cooled.
More informationThe AMK 15-2 is a high-power metal/ceramic triode, intended for use in industrial generators for frequencies
HIGH POWER TRIODE The is a high-power metal/ceramic triode, intended for use in industrial generators for frequencies up to 120 MHz and output power up to 63 kw in CW mode. Cooling is accomplished by water.
More informationPET1610F. Pilani Electron Tubes & Devices Pvt. Ltd. Forced-Air Cooled Triode. For Industrial RF Heating. Drop in equivalent of BW1610F
Forced-Air Cooled Triode For Industrial RF Heating Drop in equivalent of BW1610F Output Power: 30 kw Anode voltage: 9 kv max Anode dissipation: 10 kw max Frequency up to 30 MHz Manufactured in India, in
More informationMILADY. Product Data. Page 1 of 8
Page 1 of 8 The MILADY Mammographic Unit offers the best quality-to-price ratio to our customers worldwide. The unit advanced technology together with the application of industrial production standards,
More informationX-band Magnetron. Cooling (note 5) Water Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent
X-band Magnetron GENERAL DESCRIPTION MX7637 is a tunable X-band pulsed type magnetron intended primarily for linear accelerator. It is cooled with water and has a UG51/U (WR112) output coupling. It is
More informationAbridged Data. General Data. MG7095 Tunable S-Band Magnetron for Switched Energy Applications. Cooling. Electrical. Accessories.
The data should be read in conjunction with the Magnetron Preamble and with British Standard BS9030: 1971 Abridged Data Mechanically tuned pulse magnetron intended primarily for linear accelerators. Frequency
More informationMXHF-1500RF is controlled by Digital key panel console that displays KV, ma and mas with APR menu programmed.
R/F TV X-RAY SYSTEM DIAGNOSTIC RADIOGRAPHIC FLUOROSCOPIC TV SYSTEM MXHF-1500RF SYSTEM OUTLINE Product Data No. 041021-01 MXHF-1500RF is controlled by Digital key panel console that displays KV, ma and
More informationMG MW S-Band Magnetron
MG8076 7.5 MW S-Band Magnetron This data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Peak power output...7.5 MW Centre frequency...2998 MHz Magnet...integral magnet or separate
More informationMammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over
Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over a lifetime Breast cancer screening programs rely on
More informationX band Magnetron. Water: Anode cavity Forced-air: Input ceramics and terminals Output coupling (note 6) UG51/U Magnet (note 7) Integral, Permanent
X band Magnetron GENERAL DESCRIPTION MX7621 is a tunable X-band pulsed type magnetron intended primarily for linear accelerator. It is cooled with water and has a UG51/U (WR112) output coupling. It is
More informationM5028 Precision Tuned Magnetron
M5028 Precision Tuned Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Precision tuned pulse magnetron for linear accelerators. The tuning drive will mechanically
More informationS-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water
S-band Magnetron GENERAL DESCRIPTION is a mechanical tuned pulsed type S-band magnetron intended primarily for linear accelerator. It is water cooled and has circle waveguide output type. It is designed
More informationARU-01CF Portable X-Ray NSN:
ARU-01CF Portable X-Ray NSN: 6525-01-468-1672 COMMAND l AIR OPERATION & MAINTENANCE MANUAL Table of Contents Introduction................................................................3 Purpose.............................................................3
More informationMG6090 Tunable S-Band Magnetron
MG6090 Tunable S-Band Magnetron The data should be read in conjunction with the Magnetron Preamble and with British Standard BS9030 : 1971. ABRIDGED DATA Mechanically tuned pulse magnetron intended primarily
More informationMG7095 Tunable S-Band Magnetron
MG7095 Tunable S-Band Magnetron The data should be read in conjunction with the Magnetron Preamble and with British Standard BS9030 : 1971. ABRIDGED DATA Mechanically tuned pulse magnetron intended primarily
More informationMobileDaRt Evolution MX8 Version
PD504-021 Mobile X-ray System MobileDaRt Evolution MX8 Version MX8c type GENERAL The MobileDaRt Evolution is a general-purpose mobile digital X-ray system, which can be freely moved throughout a hospital
More informationEmotron FDU 2.0 Variable Speed Drive
Emotron FDU 2.0 Variable Speed Drive Data Sheet English Emotron FDU 2.0 Variable Speed Drive Electrical specifications related to model Table 1 Typical motor power at mains voltage 400 V Model Max. output
More informationCUSTOMER S ACCEPTANCE SPECIFICATIONS
LG FOR MESSRS : Uniservice Co. Ltd CUSTOMER S ACCEPTANCE SPECIFICATIONS MAGNETRON : 2M809 15GKH (Inverter 900W) CONTENTS DATE : Feb.20,2012 COVER 1 RECORD OF REVISION TEST SPECIFICATIONS CHARACTERISTIC
More informationCourse ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation
Course ELEC0014 - Introduction to electric power and energy systems Additional exercises with answers December 2017 Exercise A1 Consider the system represented in the figure below. The four transmission
More informationX-rays. X-rays are produced when electrons are accelerated and collide with a target. X-rays are sometimes characterized by the generating voltage
X-rays Ouch! 1 X-rays X-rays are produced when electrons are accelerated and collide with a target Bremsstrahlung x-rays Characteristic x-rays X-rays are sometimes characterized by the generating voltage
More informationEmotron FDU 2.0 Variable Speed Drive
Data Sheet Emotron FDU 2.0 Variable Speed Drive Electrical specifications related to model Table 1 Typical motor power at mains voltage 400 V Model Max. output current for 60 s [Arms] Normal duty (120%)
More informationX-ray Tube and Generator Basic principles and construction
X-ray Tube and Generator Basic principles and construction Dr Slavik Tabakov - Production of X-rays OBJECTIVES - X-ray tube construction - Anode - types, efficiency - X-ray tube working characteristics
More informationMG5193 Tunable S-Band Magnetron
MG5193 Tunable S-Band Magnetron The data should be read in conjunction with the Magnetron Preamble and with British Standard BS9030 : 1971. ABRIDGED DATA Mechanically tuned pulse magnetron intended primarily
More informationDC/DC Converter VRA_YMD-6WR3 & VRB_YMD-6WR3 Series
6W isolated - converter in YMD package Wide input voltage and regulated dual/single output CB Patent Protection RoHS FEATURES Wide 2:1 input voltage range High efficiency up to 88% No-load power consumption
More informationAC centrifugal fan. R2E180-AS backward curved, single inlet. Nominal data
Nominal data Type Motor ME68-BF Phase ~ ~ Nominal voltage VAC Frequency Hz 5 6 Type of data definition fa fa Valid for approval / standard CE CE Speed min - Power input W 8 Current draw A.6.5 Motor capacitor
More informationAC axial fan. sickled blades (S series)
4E45-P- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-7467 Mulfingen Phone +49 798 8- Fax +49 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAtomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL. Version 1.0
Atomscope PORTABLE VETERINARY X-RAY EQUIPMENT INSTRUCTION MANUAL Version 1.0 Thank you for purchasing our HFX90V portable veterinary x-ray unit. We are confident that you will be pleased with the radiographs
More informationMG5223F S-Band Magnetron
MG5223F S-Band Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Fixed frequency pulse magnetron. Operating frequency... 3050 ± 10 MHz Typical peak output power...
More informationMOBILEART eco C504-E009G
MOBILEART eco C504-E009G MobileArt eco Flexible Bedside Positioning Shimadzu s mobile X-ray system allows X-rays to be taken easily in limited spaces. This is made possible by the flexibility of the new
More informationPractix. Mobile Radiography. Constantly on the move, and yet never tired. Practix 160
Practix 160 Specifications Practix Mobile Radiography Constantly on the move, and yet never tired Practix 160 The mobile X-ray system Practix 160 offers ideal solutions for all routine examinations in
More informationAC axial compact fan
WE5-HJ8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationAC centrifugal fan - RadiCal
RE5-R9-9 ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationURA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER
URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER Patent Protection RoHS FEATURES Efficiency up to 88% Ultra wide input voltage range(4:1) Good
More informationChina Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R
China Resources Wandong Medical Equipment Co., Ltd. High Frequency 50kW, 150kV Radiography System - HF50-R Building 3, No.9, Jiuxianqiaodong Road, Chaoyang District, Beijing 100015, P.R. China E-mail:
More informationAC axial compact fan
WE5-HL6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationGE AMX 4+ Portable X-Ray
GE AMX 4+ Portable X-Ray Typical Manufacturer s Picture GE Healthcare s AMX-4+ analog X-ray system provides high-performance in a compact, easy-to-maneuver package. The rotating arm and tube simplify positioning
More informationURA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER
URA_LD-15W & URA_LD-20W Series 15/20W, 4:1ULTRA WIDE INPUT ISOLATED & REGULATED DUAL OUTPUT DC-DC CONVERTER Patent Protection RoHS FEATURES Efficiency up to 88% Ultra wide input voltage range(4:1) Good
More informationDigital Radiography System
www.drgem.co.kr GXR-SD SERIES GXR-SD SERIES Digital Radiography System GXR-SD Series www.drgem.co.kr High Performance and Reliability The Optimal System for Digital Solution The GXR-SD Series is a diagnostic
More informationTECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS
TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) BIDDER s OFFER S. No. PARTICULARS BHEL SPECIFICATIONS 1.0 Area of Application The 300kV Constant potential
More informationCB Patent Protection RoHS
3W, Ultra wide input isolated & regulated single output DC/DC converter Selection Guide Certification Part No. -- URB2403MT-3WR3 Input Voltage (VDC) Output Efficiency 2 Nominal Output Voltage Output Current
More informationDistributed by. Ecotron Anyview Series. The Intelligent C-Arm System
Distributed by Ecotron Anyview Series The Intelligent C-Arm System The Ecotron Anyview Series is a new standard for C-arm imaging Excellent radiographic imaging at an economical price Advanced X-ray Generator
More informationTHE PANTAK THERAPAX SXT 150
THE PANTAK THERAPAX SXT 150 combines the safety and ease-of-use of photon radiation therapy with state-of-the-art technology, including microprocessor control and solid-state electronics. Using Therapax,
More informationDisclosure to Promote the Right To Information
इ टरन ट म नक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information
More informationISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film
INTERNATIONAL STANDARD ISO 17636-1 First edition 2013-01-15 Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film Contrôle non destructif des assemblages soudés
More informationDisclosure to Promote the Right To Information
इ टरन ट म नक Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information
More informationAT5210 FEATURES DESCRIPTION APPLICATION. 150mA High PSRR LDO. AT X.X KE R Shipping: IAT R: Tape & Reel Circuit Type. Immense Advance Tech.
FEATURES DESCRIPTION V IN Range: 2.0V to 6.0V Low Dropout Voltage: 0.22V (Typ) (V OUT = 3.3V, I OUT = 150mA) Output Current: 150mA High Ripple Rejection: 75dB (Typ)(f= 1kHz) Excellent Line Regulation:
More informationSvetlana 3CX3000F7/8162 High-Mu Power Triode
High-Mu Power Triode T he Svetlana 3CX3F7/8162 is a high-performance ceramic/metal power triode designed for use in zero-bias, class AB, or class B RF or audio amplifiers. A modern mesh filament is used,
More informationUsing Carbon Nano-Tube Field Emitters to Miniaturize X-Ray Tubes
Using Carbon Nano-Tube Field Emitters to Miniaturize X-Ray Tubes Authors: Martin Pesce, RT(R), Xiaohui Wang, PhD, Peter Rowland X-rays are produced by the impact of an accelerated electron beam on a tungsten
More informationCX1140 Hydrogen Thyratron
CX1140 Hydrogen Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Hydrogen-filled tetrode thyratron, featuring low jitter and low anode delay time drift.
More informationDC/DC Converter URA_ZP-6WR3 & URB_ZP-6WR3 Series
/ Converter FEATURES 6W,Ultra wide input, isolated & regulated dual/ single output, DIP package, - converter CB Patent Protection RoHS Wide range of input voltage (4:1) Efficiency up to 88% No-load power
More informationCB Patent Protection RoHS
1W, Fixed input voltage, 42VAC or 6VDC isolated & unregulated positive-negative dual/single output Selection Guide Certification Part No. -- H35S-1WR2 UL CB Patent Protection RoHS G55S-1WR2 Input Voltage
More informationGlass Gas Discharge. RL501 Series. Circuit Protection System ELECTRONICS
ELECTRONICS Glass Gas Discharge RL501 Series Features Approximately zero leaking current before clamping voltage Less decay at on/off state. High capability to withstand repeated lightning strikes. Low
More informationAC centrifugal fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA
GE6-Y7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationXRC X-Ray Calibration System
XRC X-Ray Calibration System Technical Description Contents 1. Equipment overview 2. X-ray Beam Specifications 3. The Control Console 4. Radiation Safety 5. Filters 6. X-ray Generator & Heat Exchange Equipment
More informationSAMSUNG SMART DIGITAL RADIOGRAPHY. XGEO GU60A series REDEFINING ERGONOMICS
SAMSUNG SMART DIGITAL RADIOGRAPHY XGEO GU60A series REDEFINING ERGONOMICS U-arm Positioner (Fully Automated) The XGEO GU60A/60A-65 is a universal, fully motorized system. Its unique U-arm rotates +120
More informationHIGH FREQUENCY X-RAY MONOBLOCK 3.5kW
HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW The high frequency X-Ray monoblock consists of an inverter and oil-filled tank which houses the high voltage transformer and tube. It has been designed and developed
More informationE2V Technologies MG6028 Fast Tuned Magnetron
E2V Technologies MG6028 Fast Tuned Magnetron The data should be read in conjunction with the Magnetron Preamble. ABRIDGED DATA Fast tuned pulse magnetron for linear accelerators. The tuning drive will
More informationPractix. Mobile Radiography. Changing its point of view comes naturally. Practix 300
Practix 300 Specifications Practix Mobile Radiography Changing its point of view comes naturally Practix 300 With its swiveling telescopic tube arm and rotatable column, the Practix 300 adds a new and
More informationS24SP series 60W Single Output DC/DC Converter
Model List Model Number Input Voltage (Range) Output Voltage Output Current Input Current (typ input voltage) Load Regulation Maxcapacitive Load (Cap ESR>=1mohm;Full Efficiency (typ.) load;5%overshoot
More informationProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.
The premium intraoral X-ray unit... ProX Intraoral X-ray PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX. This advanced unit provides
More informationACS600, ACS800. Installation Guide
ACS600, ACS800 Installation Guide du/dt Filters AOCH0260-70 AOCH0400-70 NOCH0016-6x NOCH0030-6x NOCH0070-6x NOCH0120-6x NOCH0260-60 NOCH0400-60 NOCH0760-60 2003 ABB Oy. All Rights Reserved. 3AFE 58933368
More informationDigital medical imaging has significantly contributed to the improvement of diagnoses and the widespread use of less
RCS Paris B 337 934 483-012573-00b www.acteongroup.com Non contractual document - Ref. 707114 B - 03/2018 - Copyright 2018 ACTEON IMAGING. All rights reserved. No information or any part of this document
More informationDC/DC Converter URB_J(M)D/T-15W Series
15W isolated DC-DC converter in DIP/SMD package, Ultra-wide input & regulated single output FEATURES Ultra-wide 4:1 input voltage range High efficiency up to 89% No-load power consumption as low as 0.36W
More informationDISCRETE SEMICONDUCTORS DATA SHEET M3D319. BAP70-02 Silicon PIN diode. Product specification Supersedes data of 2002 Jul 02.
DISCRETE SEMICONDUCTORS DATA SHEET M3D319 Supersedes data of 2002 Jul 02 2002 Aug 06 FEATURES High voltage, current controlled RF resistor for attenuators Low diode capacitance Very low series inductance.
More informationCLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power
Applications Telecommunications equipment Embedded Computing Storage Systems Industrial equipment Features Compact size 50.8 mm x 101.6 mm x 36.1 mm (2 in x 4 in x 1.4 in) with density of 13.4W/in 3 Universal
More informationGE Sensing & Inspection Technologies. The ISOVOLT Titan E X-ray Generator
GE Sensing & Inspection Technologies The Titan E X-ray Generator Robust, Reliable and Highly Accurate Stationary X-ray Generators for the Widest Range of Applications. The Reference Class for X-ray generators
More informationGE Inspection Technologies. The ISOVOLT Titan E X-ray Generator
GE Inspection Technologies The Titan E X-ray Generator Robust, Reliable and Highly Accurate Stationary X-ray Generators for the Widest Range of Applications. The Reference Class for X-ray generators is
More informationQuality Design Because you pay more and more attention to the look and effectiveness of your practice
Quality Design Because you pay more and more attention to the look and effectiveness of your practice ACTEON has developed X-Mind unity with: - Uncompromising design - Clean lines - Proven quality - Superior
More informationAC diagonal compact fan
WE8-BA- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationIF_S-1W & IF_D-1W Series 1W isolated DC-DC converter with Fixed Input Voltage and Regulated Single Output
IF_S-1W & IF_D-1W Series 1W isolated - converter with Fixed Input Voltage and Regulated Single Output FEATURES Compact size SIP/DIP Package I/O isolation test voltage 3k V Operating ambient temperature
More informationHIGH FREQUENCY X-RAY MONOBLOCK 3.5kW
HIGH FREQUENCY X-RAY MONOBLOCK 3.5kW The high frequency X-Ray monoblock consists of an inverter and oil-filled tank which houses the high voltage transformer and tube. It has been designed and developed
More informationAC centrifugal fan. forward curved, dual inlet with housing (flange)
DE-DM7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More information(typ.) (Range) Parameter Model Min. Typ. Max. Unit
FEATURES Smallest Encapsulated 20W! Package Size 1.0 x1.0 x0.4 Ultra-wide 4:1 Input Range Very high Efficiency up to % Operating Temp. Range - C to +85 C Output Voltage Trimmable I/O-isolation Voltage
More informationSpec Information. Reactances Per Unit Ohms
GENERATOR DATA Spec Information Generator Specification Frame: 1647 Type: SR5 No. of Bearings: 1 Winding Type: RANDOM WOUND Flywheel: 21.0 Connection: SERIES STAR Housing: 00 Phases: 3 No. of Leads: 6
More informationEfficiency (typ.) (Range) Load. Output Current Input Current Reflected Ripple
FEATURES Highest Power Density 1" x 1" x 0.4" Shielded Metal Package Ultra Wide 4:1 Input Range Excellent Efficiency up to % Operating Temp. Range - C to + C Optional Heatsink I/O-isolation Voltage 10VDC
More informationTop-Innovator MotorAnalyzer 1. Multi-purpose testers for electric motors and windings. Made in Germany Expect more.
Top-Innovator 2014 MotorAnalyzer 1 Multi-purpose testers for electric motors and windings Made in Germany Expect more. EN Winding testers 1 The MotorAnalyzer 1 the multi-purpose tool The MotorAnalyzer
More informationAC axial compact fan
WE-HK8- ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-767 Mulfingen Phone +9 798 8- Fax +9 798 8- info@de.ebmpapst.com www.ebmpapst.com Limited partnership Headquarters Mulfingen County court Stuttgart
More informationE2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron
E2V Technologies CX1175C Deuterium-Filled Ceramic Thyratron The data to be read in conjunction with the Hydrogen Thyratron Preamble. ABRIDGED DATA Deuterium-filled two gap thyratron with ceramic envelope,
More information