Upsolar Smart Modules

Size: px
Start display at page:

Download "Upsolar Smart Modules"

Transcription

1 Upsolar Smart Modules Optimized by Energy Improve ROI with No Upfront Cost Smart Modules optimized by Energy deliver more energy, active management and enhanced safety through state-ofthe-art module-embedded power electronics. Our solution offers Smart Curve technology, which enables % longer strings. The system works with all major inverters. Build % Longer Strings BOS Cost Savings Equipped with Smart Curve Technology to dramatically reduce BOS Costs: Fixed Voc, % lower than traditional modules, not temperature dependent Longer strings, % more modules per string Lower BOS Costs fewer combiners, disconnects, feeders and less copper Maintenance Made Simple Panel-Level monitoring provides unparalleled visibility and helps maintain arrays at peak efficiency: Module-level resolution Automated commissioning Detailed alerts & analytics Access from any computer, phone, or tablet Free basic monitoring for years Highest Power Density and Efficiency Higher energy yield and mismatch tolerance from module-level MPPT: Eliminates all sources of mismatch: clouds, temperature, shade, soiling, aging, etc. More modules on any given roof or utility project Allows uneven strings and different orientations.% CEC weighted efficiency The Safest Solar Available Detects and deactivates safety threats ensuring a worry-free solar experience: PV-Safe technology eliminates the voltage of individual solar panels when safety hazards are detected Automatic detection and prevention of safety hazards

2 Smart Curve Technology What is Smart Curve? Smart Curve technology limits the maximum voltage that a module can produce. This technology allows Upsolar to create a module with a much higher fill-factor by reducing the maximum voltage output of a module to be closer to Vmp. Traditional Modules Temperature Derate & Vmp/Voc Gap. kwp Modules with Smart Curve Technology: Have % lower Open Circuit Voltages than traditional modules Open Circuit Voltage is not affected by temperature (Coefficient of Voc = ) Smart Modules Do not clip power even on extremely cold days. kwp Enable % longer strings and thus a higher average voltage V V Are CSA and TUV certified Longer Strings Just like moving from V to V or V to V systems, Smart Curve enables more modules per string with all the inherent BOS benefits. Smart Curve enables % longer strings, resulting in: % fewer combiners, disconnects, DC feeders and home runs Reduced labor costs Higher average voltage across the year without a boost transformer ~.% lower I²R losses -String Combiner -String Combiner Upsolar Modules Cell Type No. of Cells Backsheet Color Min power Max power Mono Mono Mono Mono cells cells cells Standard Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Wp Upsolar is not responsible for damages caused by errors or omissions on this data sheet. All information is subject to change without notice. Delivering safe solar

3 Poly Cells Ideal for Commercial Rooftops Polycrystalline PV module cells MODEL UP-MPT UP-MPT UP-MPT UP-MPT UP-MPT Short-Circuit Current Isc (A)......%.%.%.%.% (IEC) / (UL) ±% A * ** STC: Irradiance W/m², Module temperature ºC, AM=. Smart Curve technology reduces a module s open-circuit voltage to the Voc* value, which becomes the hard-limit of the output voltage. High Transparency Tempered Glass. //. mm Maximizer TM MMJ ES diodes - International Rectifier CTQS Amersol - (cross section:. mm ) MC, (IP, IEC and UL approved) Anodized aluminium alloy type -T EVA (.'' //. mm ±.'' //. mm thickness) - F to + F // - C to + C lbs / ft² (UL Standard) // Pa (IEC Standards) Cells Polycrystalline silicon solar cells x // mm x mm Number of Cells ( x ) Dimensions ( in // mm ) x. x. // x x Weight ( lb // kg ). //. W / m² W / m² W / m² NOCT ( C ) ± of Isc (% / C ). ±. of Pm (% / C ) -. ±. Black Type *Dotted line: std I-V curve (w/o ) Deviation of Vm (V), Im (A), Voc (V) and Isc (A) of ±.% Upsolar is not responsible for damages caused by errors or omissions on this data sheet. All information is subject to change without notice.

4 Ideal for Commercial Rooftops Monocrystalline PV module Mono MODEL UP-MMT UP-MMT UP-MMT UP-MMT UP-MMT Short-Circuit Current Isc (A)......%.%.%.%.% (IEC) / (UL) ±% A *STC: Irradiance W/m², Module temperature ºC, AM=. **Smart Curve technology reduces a module s open-circuit voltage to the Voc* value, which becomes the hard-limit of the output voltage. High Transparency Tempered Glass. //. mm Maximizer TM MMJ ES diodes - International Rectifier CTQS Amersol - (cross section:. mm ) MC, (IP, IEC and UL approved) Anodized aluminium alloy type -T EVA (.'' //. mm ±.'' //. mm thickness) - F to + F // - C to + C lbs / ft² (UL Standard) // Pa (IEC Standards) Cells Monocrystalline silicon solar cells x // mm x mm Number of Cells ( x ) Dimensions ( in // mm ). x. x. // x x Weight ( lb // kg ). //. W / m² W / m² W / m² NOCT ( C ) ± of Isc (% / C ). ±. of Pm (% / C ) -. ±. *Dotted line: std I-V curve (w/o ) Deviation of Vm (V), Im (A), Voc (V) and Isc (A) of ±.% Black Type ZEP Upsolar is not responsible for damages caused by errors or omissions on this data sheet. All information is subject to change without notice. Delivering safe solar

5 Ideal for Commercial Rooftops Poly Cells Polycrystalline PV module MODEL UP-MPT UP-MPT UP-MPT UP-MPT UP-MPT Short-Circuit Current Isc (A)......%.%.% (IEC) / (UL) ±% A.%.% *STC: Irradiance W/m², Module temperature ºC, AM=. **Smart Curve technology reduces a module s open-circuit voltage to the Voc* value, which becomes the hard-limit of the output voltage. High Transparency Tempered Glass. //. mm Maximizer TM MMJ ES diodes - International Rectifier CTQS Amersol - (cross section:. mm ) MC, (IP, IEC and UL approved) Anodized aluminium alloy type -T EVA (.'' //. mm ±.'' //. mm thickness) - F to + F // - C to + C lbs / ft² (UL Standard) // Pa (IEC Standards) Cells Polycrystalline silicon solar cells x // mm x mm Number of Cells ( x ) Dimensions ( in // mm ). x. x. // x x Weight ( lb // kg ). //. W / m² W / m² W / m² NOCT ( C ) ± of Isc (% / C ). ±. of Pm (% / C ) -. ±. *Dotted line: std I-V curve (w/o ) Deviation of Vm (V), Im (A), Voc (V) and Isc (A) of ±.% Black Type ZEP Upsolar is not responsible for damages caused by errors or omissions on this data sheet. All information is subject to change without notice.

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES TM FULL RANGE OF CERTIFIED MODULES Mono Crystalline Watt to 50 Watt Poly (Multi) Crystalline Watt to 80 Watt Glass Cells High Efficiency A-Grade

More information

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty Those who dream of a better future can help lead to a more meaningful and enriched world. As a leading solar module manufacturer in Korea, we never stop to achieve competitiveness through differentiation,

More information

Your Origin SLIVER system will be supplied with one of the following sets of panels:

Your Origin SLIVER system will be supplied with one of the following sets of panels: SLIVER3000 Solar System Panel Specifications Your Origin SLIVER system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum

More information

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range Growatt 2000TL Maximum efficiency of 97% and wide inpunt voltage range Internal DC switch Transformerless GT topology Compact design Multi MPP controller MTL - String Bluetooth / RF technology / ZigBee

More information

KIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador

KIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador KIT SOLAR ANET O 7500 Wh/día QUÉ PUEDES CONECTAR? QUÉ INCLUYE? 9 Módulos FV T RINA SOLAR 255Wp Policristalino (3 Estructuras incluidas) 24 Baterías T URBO ENERGY 8 SOPZS 1400 1 Inversor/cargador/regulador

More information

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years

More information

Quality criteria and certificates

Quality criteria and certificates Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years

More information

Application Note: String sizing Conext CL Series

Application Note: String sizing Conext CL Series : String sizing Conext CL Series 965-0066-01-01 Rev A DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This Application Note is in addition to, and incorporates by reference, the installation

More information

FSEC APPROVAL # XL15-NT

FSEC APPROVAL # XL15-NT AC GEC 4 IN SERIES TO UTILITY METER IN SERIES F-2 35A SW 60A SOLAR MODULE POWER BOX PM-25 270W 2 3 4 JUNCTION BOX 2 7 INVERTER I 6,000W 5 6 3 TO MAIN SERVICE ENTRANCE RE F. MODULES FSEC APPROVAL # XL5-NT90-02

More information

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof EN LG300N1K-G4 60 cell LG s new module, NeON 2 Black, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to enhance power output and reliability. NeON 2 Black demonstrates

More information

New Tools for PV Array Commissioning and Troubleshooting

New Tools for PV Array Commissioning and Troubleshooting New Tools for PV Array Commissioning and Troubleshooting June 30, 2011 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 Bryan Bass Sales Engineer bryan@solmetric.com Solmetric Solutions

More information

This document contains TDS for the following products: ReneSola Australia Virtus II Module W 4BB

This document contains TDS for the following products: ReneSola Australia Virtus II Module W 4BB This document contains TDS for the following products: Virtus II Module 55-70W 4BB ReneSola Australia Virtus II Module 60-70W 4BB Virtus II Module 55-70W 4BB 1000V US Virtus II Module 55W 60W 65W 70W High

More information

Solmetric PVA-600 PV Analyzer

Solmetric PVA-600 PV Analyzer Introducing the Solmetric PVA-600 PV Analyzer Paul Hernday PV Applications Engineer http://www.solmetric.com/pva600.html Bryan Bass Sales Engineer Topics Introduction to Solmetric Verifying PV array performance

More information

APPENDIX V PRODUCT SHEETS

APPENDIX V PRODUCT SHEETS National Institutes of Health Building 37 Modernization Bethesda, Maryland APPENDIX V PRODUCT SHEETS Katie L. McGimpsey Mechanical Option 1 of 4 BP 4160 160-Watt Monocrystalline Photovoltaic Module The

More information

Laboratory 2: PV Module Current-Voltage Measurements

Laboratory 2: PV Module Current-Voltage Measurements Laboratory 2: PV Module Current-Voltage Measurements Introduction and Background The current-voltage (I-V) characteristic is the basic descriptor of photovoltaic device performance. A fundamental understanding

More information

Understanding Temperature Effects on Crystalline PV Modules

Understanding Temperature Effects on Crystalline PV Modules Understanding Temperature Effects on Crystalline PV Modules The following is a discussion on temperature and how it affects solar module voltages and power output. This is particularly important in solar-battery

More information

Dr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece

Dr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece Innovation Week on PV Systems Engineering and the other Renewable Energy Systems. 1-10 July 2013, Patras, Greece Dr E. Kaplani ekaplani@teipat.gr Mechanical Engineering Dept. T.E.I. of Patras, Greece R.E.S.

More information

New Tools for PV Array Commissioning and Troubleshooting

New Tools for PV Array Commissioning and Troubleshooting New Tools for PV Array Commissioning and Troubleshooting November 10, 2011 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 Bryan Bass R&D Engineer bryan@solmetric.com Solmetric

More information

New Tools for PV Array Commissioning and Troubleshooting

New Tools for PV Array Commissioning and Troubleshooting New Tools for PV Array Commissioning and Troubleshooting Solmetric PVA-600 Megger MIT430 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 April 5, 2012 Audio is available by telephone

More information

Solmetric White Paper: Winning Contracts with PV Array Testing

Solmetric White Paper: Winning Contracts with PV Array Testing Solmetric White Paper: Winning Contracts with PV Array Testing Contents Introduction...1 Background: I-V Curves in Field Applications...2 What is an I-V curve?...2 Where has I-V curve tracing been used

More information

How to Evaluate PV Project Energy Yield

How to Evaluate PV Project Energy Yield How to Evaluate PV Project Energy Yield There are three main characteristics of a PV module that could affect the real energy generation of a PV plant: Temperature coefficient; Low light performance; IAM

More information

1MW - Gangneung, S.Korea BEYOND YOUR EXPECTATIONS TOP CLASS. topsun.kr

1MW - Gangneung, S.Korea BEYOND YOUR EXPECTATIONS TOP CLASS. topsun.kr 1MW - Gangneung, S.Korea BEYOND YOUR EXPECTATIONS TOP CLASS topsun.kr About Topsun Strategy Our people are key to success. As a gloabl solar This applies to every It s based on our vision The focus lies

More information

Commissioning and Troubleshooting PV Arrays. Solmetric PV Analyzer

Commissioning and Troubleshooting PV Arrays. Solmetric PV Analyzer Commissioning and Troubleshooting PV Arrays with the Solmetric PV Analyzer November 14, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Topics Review of I-V Curves Introduction

More information

Sunny Smile with Hyundai

Sunny Smile with Hyundai Happy Energy for the Future! Sunny Smile with Hyundai Advanced Green Solution beyond the world Hyundai Heavy Industries Happy Energy for the Future Hyundai Heavy Industries provides green solution for

More information

Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software

Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software Next PVA Webinar November 29, 10am PST http://www.solmetric.com/ webinar.html Paul Hernday Senior Applications Engineer paul@solmetric.com

More information

Array. Source-circuit configuration is arguably the most

Array. Source-circuit configuration is arguably the most Array Source-circuit configuration is arguably the most important aspect of PV system design. The electrical and mechanical characteristics of a PV array follow from this fundamental design decision, which

More information

TECHNICAL DATA SHEET. smartflower POP. As of: August 2015 Typing and printing errors reserved.

TECHNICAL DATA SHEET. smartflower POP. As of: August 2015 Typing and printing errors reserved. TECHNICAL DATA SHEET smartflower POP. TECHNICAL DATA POWER OUTPUT Nominal output Output through 2-axle tracking POP 2.31 kwp* 3.400 5.700 kwp/a** SYSTEM Modultype Modul power output warranty Module product

More information

PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer

PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer April 11, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Review of I-V Curves I-V and P-V

More information

Large Area Steady State Solar Simulator - Apollo

Large Area Steady State Solar Simulator - Apollo AllReal APOLLO series steady-state solar simulator are AAA class which is the highest class on the world. AllReal APOLLO solar simulators designed with specific optical technology by tandem Xenon lamps,

More information

PV Array Commissioning and Troubleshooting. Solmetric PV Analyzer

PV Array Commissioning and Troubleshooting. Solmetric PV Analyzer PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer May 9, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Next webinar: May 30 http://www.solmetric.com/webinar.html

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19631307.002 Bangalore, May 2017 Certificate No. T -1543 2 / 17 Contents CONTENTS... 2

More information

GRID-CONNECTED SOLAR PV SYSTEMS. Design Guidelines for Accredited Installers NO BATTERY STORAGE. January 2013 (Effective 1 February 2013)

GRID-CONNECTED SOLAR PV SYSTEMS. Design Guidelines for Accredited Installers NO BATTERY STORAGE. January 2013 (Effective 1 February 2013) GRID-CONNECTED SOLAR PV SYSTEMS NO BATTERY STORAGE Design Guidelines for Accredited Installers January 2013 (Effective 1 February 2013) These guidelines have been developed by Clean Energy Council. They

More information

mono-crystalline silicon solar cells mm No. of cells and connections 72(6 12)

mono-crystalline silicon solar cells mm No. of cells and connections 72(6 12) Rated Maximum Power (P ma x) Current at P max (Imp ) Voltage at P max (V mp) Short-Circuit Current (I SC ) Open-Circuit Voltage (V OC ) Nominal Operating Temp.(T N OCT ) ll technical data at STC:1000W/m

More information

Colour your life! BISOL Spectrum Series. www. bisol. com

Colour your life! BISOL Spectrum Series. www. bisol. com Colour your life! BISOL Spectrum Series www. bisol. com BISOL Spectrum Series With respect for our natural surrounding and the architectural legacy in mind, we are introducing an exclusive BISOL Spectrum

More information

String Configuration Tool Help!

String Configuration Tool Help! String Configuration Tool Help! (Siento, esto solo está en inglés) 1 Intended Use and Disclaimer Thank you for using the Fronius String Configuration Tool ( FSC Tool ) for North America. Fronius USA provides

More information

TEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval

TEST REPORT IEC 61215: nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval Test Report issued under the responsibility of: TEST REPORT IEC 61215: 2005 2nd Edition Crystalline Silicon Terrestrial Photovoltaic (PV) Modules - Design Qualification and Type Approval Report Reference

More information

Traditional PWM vs Morningstar s TrakStar MPPT Technology

Traditional PWM vs Morningstar s TrakStar MPPT Technology Traditional PWM vs Morningstar s TrakStar MPPT Technology Morningstar s MPPT charge controllers use our patented TrakStar advanced control MPPT algorithm to harvest maximum power from a Solar Array s peak

More information

Page 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37

Page 1 of 37. ULI-NABL(ELT)-MNRE-0053/2011 Date of issue... : Total number of pages... 37 Page 1 of 37 Test Report issued under the responsibility of: TEST REPORT IEC 61215 PV Module Safety Qualification Requirements for testing Report Reference No.... : ULI-NABL(ELT)-MNRE-0053/2011 Date of

More information

Performance of high-eciency photovoltaic systems in a maritime climate

Performance of high-eciency photovoltaic systems in a maritime climate Loughborough University Institutional Repository Performance of high-eciency photovoltaic systems in a maritime climate This item was submitted to Loughborough University's Institutional Repository by

More information

SILICon IrrADIAnCe SenSor

SILICon IrrADIAnCe SenSor Measurement of Solar Silicon irradiance sensors (Si sensor) show a cost-effective, but rugged and reliable solution for the measurement of solar irradiance, especially for the monitoring of Photovoltaic

More information

PORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER

PORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER PORTABLE LED FLASHER WITH IMPLEMENTED BYPASS DIODE TESTER Daniel Schär 1, Franz Baumgartner ZHAW, Zurich University of Applied Sciences, School of Engineering, IEFE www.zhaw.ch/~bauf, Technikumstr. 9,

More information

APS M1P Single-phase Micro-inverter Installation and User Manual

APS M1P Single-phase Micro-inverter Installation and User Manual APS M1P Single-phase Micro-inverter Installation and User Manual Version: 2.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR

More information

CP /240-MC4 User Manual

CP /240-MC4 User Manual CP-250-60-208/240-MC4 User Manual Chilicon Power LLC Jan 2014 1 CONTENTS Important Safety Instructions... 3 Safety Instructions... 3 CP-250 Microinverter System Introduction... 4 Inverter Label Information...

More information

Presented in Electrical & Computer Engineering University of New Brunswick Fredericton, NB, Canada The Photovoltaic Cell

Presented in Electrical & Computer Engineering University of New Brunswick Fredericton, NB, Canada The Photovoltaic Cell Presented in Electrical & Computer Engineering University of New Brunswick Fredericton, NB, Canada Introduction The The concept and PVA Characteristics Modeling Operating principles Control strategies

More information

LOW VOLTAGE PV ARRAY MODEL VERIFICATION ON COMPUTER AIDED TEST SETUP

LOW VOLTAGE PV ARRAY MODEL VERIFICATION ON COMPUTER AIDED TEST SETUP POZNAN UNIVE RSITY OF TE CHNOLOGY ACADE MIC JOURNALS No 84 Electrical Engineering 2015 Adam TOMASZUK* LOW VOLTAGE PV ARRAY MODEL VERIFICATION ON COMPUTER AIDED TEST SETUP Low voltage photovoltaic (PV)

More information

PV Module Fundamentals

PV Module Fundamentals ESS 032 Intermediate Photovoltaic Systems PV Module Fundamentals ESS 034 Advanced Photovoltaic Systems Lesson Plan Review midterm exam Solar Energy Fundamentals any questions? NABCEP Learning Objectives:

More information

The Nanosolar Utility Panel An Overview of the Solar Panel and its Advantages. May 2010

The Nanosolar Utility Panel An Overview of the Solar Panel and its Advantages. May 2010 May 2010 The Nanosolar Utility Panel 1 Designed for Utility-Scale Performance The Nanosolar Utility Panel is specifically designed for utility-scale systems. Engineered to reduce totalsystem cost, the

More information

Reference: Photovoltaic Systems, p

Reference: Photovoltaic Systems, p PV systems are comprised of building blocks of cells, modules and arrays to form a DC power generating unit with specified electrical output. Reference: Photovoltaic Systems, p. 115-118 Reference: Photovoltaic

More information

APS M1P Single-phase Micro-inverter Installation and User Manual

APS M1P Single-phase Micro-inverter Installation and User Manual APS M1P Single-phase Micro-inverter Installation and User Manual Version: 1.0 ALTENERGY POWER SYSTEM, INC. All rights reserved 1 Contact Information ALTENERGY POWER SYSTEM Inc. 1 Yatai Road, Jiaxing, PR

More information

Engineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin

Engineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin Simulation of the effects of global irradiance, ambient temperature and partial shading on the output of the photovoltaic module using MATLAB/Simulink and ICAP/4 A report submitted to the School of Engineering

More information

Modelling and simulation of PV module for different irradiation levels Balachander. K Department of EEE, Karpagam University, Coimbatore.

Modelling and simulation of PV module for different irradiation levels Balachander. K Department of EEE, Karpagam University, Coimbatore. 6798 Available online at www.elixirpublishers.com (Elixir International Journal) Electrical Engineering Elixir Elec. Engg. 43 (2012) 6798-6802 Modelling and simulation of PV module for different irradiation

More information

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China Applicant... : Manufacturer... : Order No.... : Zhejiang ERA Solar Technology Co., Ltd. Sihai Road, Huangyan Economic Development Zone, Taizhou, Zhejiang 318020, P.R. China Zhejiang ERA Solar Technology

More information

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC

Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC BUILDING AND SAFETY DIVISION 1685 MAIN STREET, SANTA MONICA, CA 90401 310-458-2201 Basic Information Required for Photovoltaic Plan Check Submittal *Informational Purposes Only* 2013 CEC ADMINISTRATIVE

More information

For more information:

For more information: Verify Tab Click on the Verify tab to compare the measured and predicted max power values. Their ratio, in percent, is the Performance Factor. Solmetric PVA-600 PV Analyzer Quick Start Guide History Tab

More information

Conext CL-60E Inverter

Conext CL-60E Inverter Conext CL-60E Inverter Solution Guide for Decentralized PV Systems solar.schneider-electric.com Copyright 2017 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries

More information

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates 4th PV Performance Modelling and Monitoring Workshop 22nd and 23rd October, 2015 M. Schweiger TÜV Rheinland Energie

More information

ENGLISH. The Science Behind the Tigo Energy Maximizer Series Product (MM-ES) Tigo Energy Inc. 420 Blossom Hill Road Los Gatos, CA 95032

ENGLISH. The Science Behind the Tigo Energy Maximizer Series Product (MM-ES) Tigo Energy Inc. 420 Blossom Hill Road Los Gatos, CA 95032 ENGLISH The Science Behind the Tigo Energy Maximizer Series Product (MM-ES) Tigo Energy Inc. 420 Blossom Hill Road Los Gatos, CA 95032 Tigo Energy has developed a revolutionary solution for harvesting

More information

EE Grid-Tied PV Systems. Y. Baghzouz Spring 2011

EE Grid-Tied PV Systems. Y. Baghzouz Spring 2011 EE 495-695 Grid-Tied PV Systems Y. Baghzouz Spring 2011 Applicable Codes & Standards Most Important: NEC IEEE Std 1547 Summary of Content of NEC NEC (Voltage Drop Requirement) NEC requires that the voltage

More information

Power Rating of Multi-junction Solar Cells: Focus Thin Film

Power Rating of Multi-junction Solar Cells: Focus Thin Film Power Rating of Multi-junction Solar Cells: Focus Thin Film Content: 1. Basics of current matching a short review 2. Requirements on Solar Simulator 3. Status of Test labs concerning thin film tandem Prof.

More information

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 4, 116, 12M Open access books available International authors and editors Downloads Our authors

More information

The European Commission s science and knowledge service

The European Commission s science and knowledge service The European Commission s science and knowledge service Joint Research Centre TEMPERATURE COEFFICIENTS OF N-TYPE BIFACIAL SILICON PV MODULES UNDER NATURAL AND SIMULATED SUNLIGHT Juan Lopez-Garcia, Diego

More information

Supplemental Calculation Sheets for Inverter #2

Supplemental Calculation Sheets for Inverter #2 Solar PV Standard Plan Simplified Central/String Inverter Systems for One and TwoFamily Dwellings (10 KW or Less) Supplemental Calculation Sheets for Inverter #2 FORM PV 3S DC Information: Module Manufacturer:

More information

Elgar ETS TerraSAS. 1kW-1MW V. Standalone TerraSAS Photovoltaic Simulator

Elgar ETS TerraSAS. 1kW-1MW V. Standalone TerraSAS Photovoltaic Simulator Elgar ETS TerraSAS Standalone TerraSAS Photovoltaic Simulator Low output capacitance High bandwidth up to 30kHz High resolution I-V curve simulates static and dynamic conditions Designed for high speed

More information

Chapter 4. Impact of Dust on Solar PV Module: Experimental Analysis

Chapter 4. Impact of Dust on Solar PV Module: Experimental Analysis Chapter 4 Impact of Dust on Solar PV Module: Experimental Analysis 53 CHAPTER 4 IMPACT OF DUST ON SOLAR PV MODULE: EXPERIMENTAL ANALYSIS 4.1 INTRODUCTION: On a bright, sunny day the sun shines approximately

More information

CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS

CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS 85 CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS 5.1 PERTURB AND OBSERVE METHOD It is well known that the output voltage and current and also the output power of PV panels vary with atmospheric conditions

More information

Leading the World in PV Test Solutions

Leading the World in PV Test Solutions seawardsolar.com Leading the World in PV Test Solutions seawardsolar.com/usa The Seaward Solar range of electrical safety test solutions enables PV installers to meet all testing and certification requirements

More information

Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool

Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool Author: Gianluca Marri Approver: Antonio Rossi Date: 2012/05/03

More information

Quality Assurance in Solar with the use of I-V Curves

Quality Assurance in Solar with the use of I-V Curves Quality Assurance in Solar with the use of I-V Curves Eternal Sun Whitepaper Written by: RJ van Vugt Introduction I Installers, wholesalers and other parties use performance tests in order to check on

More information

Design Optimization of Solar PV Power Plant for Improved Efficiency of Solar PV Plant by Maximum Power Point Tracking System

Design Optimization of Solar PV Power Plant for Improved Efficiency of Solar PV Plant by Maximum Power Point Tracking System Design Optimization of Solar PV Power Plant for Improved Efficiency of Solar PV Plant by Maximum Power Point Tracking System Abstract Maximum power point tracking (MPPT) is a method that grid connected

More information

Solmetric PVA-1000S Startup Training

Solmetric PVA-1000S Startup Training Solmetric PVA-1000S Startup Training March 22, 2015 Instructor: Paul Hernday Senior Applications Engineer paul@solmetric.com Topics Introduction to the PVA-1000S PV Analyzer Using the software Making I-V

More information

INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES

INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES INSTALLATION, USE AND MAINTENANCE MANUAL FOR THE STANDARD RANGE OF ISOFOTON PHOTOVOLTAIC MODULES - Page 1/13. Appendix II - CONTENT 1. INTRODUCTION...3 2. TECHNICAL DATA...3 3. PROTECTION DIODES...6 4.

More information

Compact Solar Cell Ultra-Wideband Dipole Antenna

Compact Solar Cell Ultra-Wideband Dipole Antenna Compact Solar Cell Ultra-Wideband Dipole Antenna Mina Danesh*, John R. Long High-Frequency Electronics Research Lab July 16, 2010 Delft University of Technology Challenge the future Outline Motivation

More information

Commercial Design 101 with HelioScope

Commercial Design 101 with HelioScope Commercial Design 101 wi HelioScope Introduction HelioScope makes it easy for non-experts to generate high-quality layouts for commercial PV arrays. For designers new to commercial system design, we have

More information

Field Applications. for I-V Curve Tracers. Silicon PV modules are. By Paul Hernday. I-V Curve Measurements

Field Applications. for I-V Curve Tracers. Silicon PV modules are. By Paul Hernday. I-V Curve Measurements Field Applications for I-V Curve Tracers By Paul Hernday Courtesy Integrated Energy Systems, Pittsburg Unified School District, Sage Renewables, Solmetric, Stellar Energy Solutions While indispensible

More information

Photovoltaic System Commissioning and Testing A Guide for PV System Technicians and Engineers

Photovoltaic System Commissioning and Testing A Guide for PV System Technicians and Engineers 4097 PV Com & Test_CoverV3:Layout 2 28/6/12 09:41 USA Office: Seaward Group USA 6304 Benjamin Road, Suite 506, Tampa, Florida, 33634 Page 2 Part of Tel: +1 (813) 886-2775 Email: enquiry@seawardsolar.com

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report

TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality. Test Report TUV Rheinland (India) Pvt. Ltd. Product Safety & Quality Test Report Photovoltaic module Testing TÜV Report No. 19630304.001 Bangalore, JULY 2015 Certificate No. T -1543 2 / 8 Contents CONTENTS... 2

More information

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC

TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality. Test Report. Salt Mist corrosion Testing of Photovoltaic modules acc IEC TUV Rheinland (India) Pvt. Ltd. Product Safety &Quality Test Report Salt Mist corrosion Testing of Photovoltaic modules acc IEC 61701-2011 TÜV Report No: 19630874.001 Bangalore JULY 2016 Certificate No.

More information

Solar Simulation Standards and QuickSun Measurement System. Antti Tolvanen Endeas Oy

Solar Simulation Standards and QuickSun Measurement System. Antti Tolvanen Endeas Oy Solar Simulation Standards and QuickSun Measurement System Antti Tolvanen Endeas Oy 1 Endeas in Brief QuickSun Solar Simulators Technology invented 1996 in Fortum (www.fortum.com) Endeas Oy licenses technology

More information

PV module one-diode model as implemented in PVsyst

PV module one-diode model as implemented in PVsyst PV module one-diode model as implemented in PVsyst 1st European Workshop on PV performance modelling INES, Le Bourget-du-Lac, 22-23 February 2013 André Mermoud andre.mermoud@pvsyst.com PVSYST SA - Route

More information

Auftrags-Nr.: Order No.: Auftragsdatum: Order date:

Auftrags-Nr.: Order No.: Auftragsdatum: Order date: Prüfbericht-Nr.: 21290449.001 Auftrags-Nr.: Order No.: 21243643 Seite 1 von 10 Page 1 of 10 Kunden-Referenz-Nr.: Client Reference No.: 3201853 Auftragsdatum: Order date: 15 May 2018 Auftraggeber: Client:

More information

A Revision of IEC nd Edition Data Correction Procedures 1 and 2: PV Module Performance at Murdoch University

A Revision of IEC nd Edition Data Correction Procedures 1 and 2: PV Module Performance at Murdoch University School of Engineering and Information Technology ENG470 Engineering Honours Thesis A Revision of IEC 60891 2 nd Edition 2009-12 Data Correction Procedures 1 and 2: PV Module Performance at Murdoch University

More information

OUTDOOR PV MODULE DEGRADATION OF CURRENT-VOLTAGE PARAMETERS

OUTDOOR PV MODULE DEGRADATION OF CURRENT-VOLTAGE PARAMETERS OUTDOOR PV MODULE DEGRADATION OF CURRENT-VOLTAGE PARAMETERS Ryan M. Smith Dirk C. Jordan Sarah R. Kurtz National Renewable Energy Laboratory 1617 Cole Boulevard Golden, CO 80401 email: ryan.smith@nrel.gov

More information

E-catalogs of BIM objects for the PVSITES products

E-catalogs of BIM objects for the PVSITES products This project has received funding from the European Union s Horizon 2020 research and innovation programme under grant agreement Nº 691768 E-catalogs of BIM objects for the PVSITES products Project report

More information

Peter Hoberg VP Marketing

Peter Hoberg VP Marketing Peter Hoberg VP Marketing Topics Why measure shade? Important terms and concepts Operating the Solmetric SunEye Resources for more information Why measure shade? Choose optimum location for panels Predict

More information

Committee E44 on Solar, Geothermal and Other Alternative Energy Sources

Committee E44 on Solar, Geothermal and Other Alternative Energy Sources Committee E44 on Solar, Geothermal and Other Alternative Energy Sources Formed in 1978 Meets once a year during November Committee Week Current membership of approximately 70 Jurisdiction over 49 standards

More information

Installation/User Manual

Installation/User Manual Installation/User Manual APS YC500-A Photovoltaic Grid-connected Inverter Version 4.1 1/15 APS America 1015 Hostmark St. Ste 104; Poulsbo, WA 98370 TEL: 206-855-5100 EMAIL: info@apsamerica.com WEB: www.apsamerica.com

More information

TEST REPORT Ammonia Resistance Testing of Photovoltaic (PV) Modules - Design Qualification and Type Approval

TEST REPORT Ammonia Resistance Testing of Photovoltaic (PV) Modules - Design Qualification and Type Approval Test Report issued under the responsibility of: TEST REPORT Ammonia Resistance Testing of Photovoltaic (PV) Modules - Design Qualification and Type Approval Report Reference No.... : 924214-3972-0001/157051

More information

Installation requirements

Installation requirements Installation requirements for SUNNY CENTRAL 500U 1 Contents This document describes the requirements which have to be observed for the installation site of the Sunny Central 500U. The installation and

More information

PV200. Why buy the PV200? The most compact I-V curve tracer around.

PV200. Why buy the PV200? The most compact I-V curve tracer around. The PV200 is a compact & cost effective I-V curve tracer that uses simple push button operation making it an efficient and versatile tester for PV systems. 999 datasets can be stored on the instrument

More information

Operating Manual BENNING PV Link App

Operating Manual BENNING PV Link App Operating Manual BENNING PV Link App ========================================================== Table of contents 1. Registration 2. Start screen 2.1 Functional elements 3. Reading new measurement data

More information

An Analysis of a Photovoltaic Panel Model

An Analysis of a Photovoltaic Panel Model An Analysis of a Photovoltaic Panel Model Comparison Between Measurements and Analytical Models Ciprian Nemes, Florin Munteanu Faculty of Electrical Engineering Technical University of Iasi Iasi, Romania

More information

Effect of I-V translations of irradiance-temperature on the energy yield prediction of PV module and spectral changes over irradiance and temperature

Effect of I-V translations of irradiance-temperature on the energy yield prediction of PV module and spectral changes over irradiance and temperature Loughborough University Institutional Repository Effect of I-V translations of irradiance-temperature on the energy yield prediction of PV module and spectral changes over irradiance and temperature This

More information

Advanced Test Equipment Rentals

Advanced Test Equipment Rentals Established 1981 Advanced Test Equipment Rentals Solmetric PVA-600 PV Analyzer Quick Start Guide www.atecorp.com 800-404-ATEC (2832) : When using the wireless PVA Sensor Kit or manual sensors, the end

More information

Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum

Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum Loughborough University Institutional Repository Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum This item was submitted

More information

The Single Diode Model of I-V and P-V Characteristics using the Lambert W Function

The Single Diode Model of I-V and P-V Characteristics using the Lambert W Function The Single Diode Model of I-V and P-V Characteristics using the Lambert W Function Shivangi Patel 1 M.E. Student, Department of Electrical Engineering, Sarvajanik College of Engineering & Technology, Athawagate,

More information

Low Cost MPPT Algorithms for PV Application: PV Pumping Case Study. M. A. Elgendy, B. Zahawi and D. J. Atkinson. Presented by:

Low Cost MPPT Algorithms for PV Application: PV Pumping Case Study. M. A. Elgendy, B. Zahawi and D. J. Atkinson. Presented by: Low Cost MPPT Algorithms for PV Application: PV Pumping Case Study M. A. Elgendy, B. Zahawi and D. J. Atkinson Presented by: Bashar Zahawi E-mail: bashar.zahawi@ncl.ac.uk Outline Maximum power point tracking

More information

Design, construction and characterization of a steady state solar simulator

Design, construction and characterization of a steady state solar simulator Design, construction and characterization of a steady state solar simulator T.V. Mthimunye, E.L Meyer and M. Simon Fort Hare Institute of Technology, University Of Fort Hare, Alice Tmthimunye@ufh.ac.za

More information

1OO % transparency = 1OO % performance. SunSniffer: the operating system for PV plants, monitoring and. Secure your solar investment

1OO % transparency = 1OO % performance. SunSniffer: the operating system for PV plants, monitoring and. Secure your solar investment Secure your solar investment inside 1OO % transparency = 1OO % performance SunSniffer: the operating system for PV plants, monitoring and www.innoway-sea.com www.innoway-sea.com page 2 How to read this

More information

CHAPTER 5 CIRCUIT MODELING METHODOLOGY FOR THIN-FILM PHOTOVOLTAIC MODULES

CHAPTER 5 CIRCUIT MODELING METHODOLOGY FOR THIN-FILM PHOTOVOLTAIC MODULES 106 CHAPTER 5 CIRCUIT MODELING METHODOLOGY FOR THIN-FILM PHOTOVOLTAIC MODULES 5.1 INTRODUCTION In this Chapter, the constructional details of various thin-film modules required for modeling are given.

More information

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR Building Division 1855 Placer Street, Suite 102 Redding, California 96001 Phone: (530) 225-5761 Fax: (530) 245-6468 Inspection Request Line: (530) 244-5068 Web:

More information