New Tools for PV Array Commissioning and Troubleshooting

Size: px
Start display at page:

Download "New Tools for PV Array Commissioning and Troubleshooting"

Transcription

1 New Tools for PV Array Commissioning and Troubleshooting November 10, 2011 Paul Hernday Applications Engineer cell Bryan Bass R&D Engineer

2 Solmetric Solutions

3 Annual Insolation Tool (web based)

4 Roof Azimuth Tool (web based)

5 Compound Angle Tool (downloadable)

6 Today s Topics PV array performance verification Introduction to I-V curves The Solmetric PVA-600 PV Analyzer Live demo of the PV Analyzer user interface Commissioning PV Arrays Troubleshooting PV arrays De-mystifying shading

7 Array Performance Test Methods For Startup/Commissioning/Checkups/Service Alarms Inverter readout String DC measurements String I-V curve measurements Basic Comprehensive I V Verification methods are evolving in response to increasing emphasis on energy production (rather than up-front incentives).

8 What is I-V Curve Tracing? Adjustable Load Measure voltage Measure current Built-in PV models mean user can instantly check performance against expectations for the existing irradiance and temperature. Current Voltage Load can be Resistive Capacitive Electronic

9 I-V Curve Tracing I-V curve measurements provide direct performance characterization and verification, as well as a diagnostic tool for periodic PV system performance assessments. I-V curve tracing is the most informative measurement that can be performed on a PV module or array. David King DK Solar Works Developer of the Sandia PV Array Model at Sandia National Labs SolarPro, Aug/Sep 2011 I often tell students in my classes to learn to think like a PV array. Thinking like a PV array requires understanding the I-V curve and how it changes based on ambient conditions and array problems. An I-V curve tracer is the best way to gain an understanding of these changes, since it provides a graphical representation of the array operating characteristics. Bill Brooks Brooks Engineering SolarPro, Aug/Sep 2011

10 PV Analyzer Users EPC Organizations System Integrators O&M Companies PV Module Manufacturers Consulting Engineers PV Inverter Manufacturers College PV Instructors Training Organizations IBEW Training Centers

11 Benefits of I-V Curve Performance Testing Commissioning New PV Systems A single electrical connection & a single measurement The most comprehensive PV measurement possible No need to bring the inverter on-line to fully test the array Close out projects earlier ($$$ flow earlier) Detailed baseline for comparison as arrays age & degrade Comply with IEC (commissioning grid-tie PV systems) Maintaining PV Systems (O&M, Asset Management) Troubleshoot more efficiently Sort out module versus inverter issues Provide convincing data for module warranty claims Keep arrays producing maximum energy

12 Benefits of I-V Curve Performance Testing Developing an Analytical Capability Take advantage of string-level performance statistics to set appropriate system margins & set appropriate pass-fail criteria Better understand and account for PV module degradation Provide stronger foundation for performance estimates and guarantees.

13 Today s Topics PV array performance verification Introduction to I-V curves The Solmetric PVA-600 PV Analyzer Live demo of the PV Analyzer user interface Commissioning PV Arrays Troubleshooting PV arrays De-mystifying shading

14 Solar Cell Photon 3 1. Charge generation 2. Charge separation 3. Charge collection Cells are in series a single cell can be a bottleneck. A 12-module string may have 12 x 72 = 864 cells in series.

15 I-V and P-V* Curves Expect this shape for healthy cells, modules, strings, arrays Isc Imp I-V curve Pmax Current P-V curve Power Voltage Vmp Voc *P-V curve is calculated from the measured I-V curve

16 Stacking PV Modules I Current Parallel I-V building Series Total (net) I-V curve blocks V Voltage This building block graphic is useful in troubleshooting arrays. Blocks can also represent cell strings within modules.

17 I-V Curve Signatures of PV Problems Isc Current (A) Reduced current Normal I-V curve Shunt losses* Mismatch losses (incl. shading) Any reduction of the knee of the curve means reduced output power. Series losses** Max power point Voltage (V) Reduced voltage Voc Conventional measurements do not reveal many of these effects.

18 Useful diagnostics Fill Factor, Current Ratio, Voltage Ratio Isc Imp Current ratio Imp/Isc Max Power Point Current Voltage ratio Vmp/Voc Voltage Vmp Voc Fill Factor = Imp x Vmp (watts) Isc x Voc (watts) = asi: xsi: GaAs:

19 Today s Topics PV array performance verification Introduction to I-V curves The Solmetric PVA-600 PV Analyzer Live demo of the PV Analyzer user interface Commissioning PV Arrays Troubleshooting PV arrays De-mystifying shading

20 Solmetric PVA-600 PV Analyzer Single connection & measurement Detailed performance picture Comparison to built-in model (5 dots) Convenient wireless interface Rugged and easy to use String measurement showing I-V and P-V curves, and comparison of I-V curve with model (5 dots).

21 Example Measurement Setup Courtesy of Chevron Energy Solutions 2011

22 Wireless Sensor Kit Irradiance & temperature sensors Irradiance transmitter. K-type thermocouple Omega Part # 5SRTC-GG-K Receiver (USB) Temperature transmitter

23 Mounting the Thermocouple Use metalized HVAC tape or Kapton tape for high temperature stability Press firmly to assure intimate contact between TC and backside Fold a tab so you can remove the tape Suggested replacement TC: Beaded K-type Omega Part No. 5SRTC-GG-K-30-72

24 PVA-600 Block Diagram (simplified) Battery charging connector CPU & wireless module C (1 of 3) V sense PV Source I sense Control button with LED indicator NEMA 4X FG Enclosure Capacitive load method. Electrically isolated. Ground lead is not required. Protected for over-voltage, -current, -temperature, & reverse polarity.

25 PVA-600 Specifications Max DC input voltage: 600V Max DC input current: 20A* Maximum DC power: Min recommended Voc: Min recommended Isc: I-V measurement time: Points per I-V trace: Storage capacity: Safety: *Strings of high-efficiency modules should be measured singly, not in parallel 12 KW (instantaneous) 20V 1A mS typical 100 (typical) 1,000+ (PC running PVA SW) IEC Measuring Category CAT III, 600V

26 Comparing PVA measurement with resistive load method

27 Data points from the resistive load method Method: Clear sky, solar noon. Quickly alternate the two methods. New resistance at each load point.

28 PV Models in the PV Analyzer Predict PV array performance for immediate comparison Sandia National Labs PV Array Model Most comprehensive (30 + parameters) ~500 PV modules 5-Parameter Model Developed at U. Wisconsin, used by CEC for NSHP program ~5000 PV modules Simple Datasheet Model (predicts Pmax) User enters data sheet parameters (Isc, Voc, Pmax & temp co s) Translates datasheet Pmax (STC) to actual irradiance & temperature These 3 methods are available in the Solar Advisor Model (SAM) from NREL and are embedded in the Solmetric PV Analyzer.

29 Today s Topics PV array performance verification Introduction to I-V curves The Solmetric PVA-600 PV Analyzer Live demo of the PV Analyzer user interface Commissioning PV Arrays Troubleshooting PV arrays De-mystifying shading

30 Today s Topics PV array performance verification Introduction to I-V curves The Solmetric PVA-600 PV Analyzer Live demo of the PV Analyzer user interface Commissioning PV Arrays Troubleshooting PV arrays De-mystifying shading

31 Example Measurement Setup

32 Example Measurement Setup Courtesy of: Integrated Energy Systems Pittsburg Unified School District Sage Renewables Stellar Energy Solutions

33 I-V Measurement Setup Example: Measuring strings at a combiner box * *Electrically isolate buss bars, then connect PVA.

34 Test Process Example: Measuring strings at a combiner box Hardware setup (do once at each combiner box): 1. Place the irradiance & temperature sensors 2. Isolate the combiner box (open the DC disconnect) 3. De-energize the buss bars (lift the string fuses) 4. Clip test leads to the buss bars Electrical measurement (repeat for each string): 1. Insert a string fuse 2. Press Measure 3. View and save results 4. Lift the fuse 15 seconds typically

35 Example Measurement Setup 860kW 7-inverter system Courtesy of Portland Habilitation Center and Dynalectric Oregon

36 Example Measurement Setup Combiner boxes for one inverter Courtesy of Portland Habilitation Center and Dynalectric Oregon

37 Example Measurement Setup Combiner boxes for one inverter Courtesy of Portland Habilitation Center and Dynalectric Oregon

38 Example Measurement Setup Combiner box wiring Courtesy of Portland Habilitation Center and Dynalectric Oregon

39 Example Measurement Setup Insert a single fuse to test the corresponding string Courtesy of Portland Habilitation Center and Dynalectric Oregon

40 How Data Is Stored This format allows the I-V Data Analysis Tool to: Array Tree Automatically analyze your data Identify non-conforming strings Provide convincing charts for your commissioning report

41 Displays Generated by the I-V Data Analysis Tool* Current (Amps) Voltage (Volts) Frequency *Optional, MS Excel-based tool, $ Pmax (Watts)

42 Recommended Sky Conditions For Array Performance Testing Clear sky (for high, stable irradiance) Irradiance affects mainly the height of the I-V curve (Isc, Imp) Consistent irradiance makes it easier to show uniformity, or to spot performance issues I-V curves change shape as irradiance decreases Translation to STC from low light conditions is much less accurate 4 hour window centered on solar noon* Low light issue as mentioned above Angle of incidence and spectral effects come into play Low/No wind (for more consistent module temperature) Temperature affects mainly the width of the I-V curve (Voc, Vmp) Temperature is not uniform across an array under any conditions Wind keeps changing the temperature pattern, making it difficult to compare one string result with another. *Solar Noon Calculator:

43 Problem Sky Conditions Small clouds Easily overlooked Causes 20% variation in irradiance Changes in seconds.

44 Problem Sky Conditions Cirrus clouds Easily overlooked Causes 10% variation in irradiance Changes in seconds.

45 Problem Sky Conditions Cloud Cloud edge effect effect Boosts irradiance up to 30% Changes in seconds.

46 Today s Topics PV array performance verification Introduction to I-V curves The Solmetric PVA-600 PV Analyzer Live demo of the PV Analyzer user interface Commissioning PV Arrays Troubleshooting PV arrays De-mystifying shading

47 I-V Curve Signatures of PV Problems Isc Current (A) Reduced current Normal I-V curve Shunt losses* Mismatch losses (incl. shading) Any reduction of the knee of the curve means reduced output power. Series losses** Max power point Voltage (V) Reduced voltage Voc Conventional measurements do not reveal many of these effects.

48 String of Field-aged, Early TF Modules Degraded fill factor, lower output power Array-as-sensor mode for viewing relative changes in curve shape

49 Troubleshooting example Anomalous slope in string I-V caused by single high-resistance module Current - A String 4B14 String 4B Voltage - V

50 Example of a series resistance failure inside a module J-box

51 Dropped Cell String Shorted bypass diode, or Mismatch causing diode to turn on when current starts flowing

52 Partially shaded residential array Measure the single string mounted along lower edge of roof

53 I-V Curve of the partially shaded string Single string mounted along lower edge of roof Approximately 40% reduction in string s output power

54 Today s Topics PV array performance verification Introduction to I-V curves The Solmetric PVA-600 PV Analyzer Live demo of the PV Analyzer user interface Commissioning PV Arrays Troubleshooting PV arrays De-mystifying shading

55 Shading Myth #1 Myth: If you completely shade one cell, that entire PV module or PV string stops producing energy. Fact: In grid-tie systems, bypass diodes turn on, shunting current around the shaded cell strings (sub-strings) and keeping the rest of the string in production.

56 Review of Bypass Diodes The purpose of bypass diodes: Preserve performance and prevent damage under mismatch conditions, including non-uniform shading

57 PV System in Full Sun Thought experiment - No bypass diodes 360v Inverter dc input voltage Each column represents a string of PV modules System operating at Pmax Each cell represents ½ volt We re going to shade this cell 5A, 0.5V Inverter 0v

58 Effect of Shading One Cell Thought experiment - No bypass diodes 360v Inverter dc input voltage + 5A, 0.5V + When this voltage becomes + + These cells shift to a lower current, higher voltage operating point: large enough, the cell breaks down and conducts in the reverse direction. 3A, 0.52v Inverter 0v

59 Effect of Shading One Cell When bypass diode is not present or has failed open 85 Heating of a Single Shaded Cell Backside temperature with no bypass diodes 80 Un-shaded (control) cell Shaded cell Temperature (C) Shaded cell Unshaded cell Single module, full sun Output short circuited 3 cell strings All 3 BP diodes removed Single cell shaded Shade Duration (seconds)

60 Introducing Bypass Diodes Example: Current flow in an un-shaded 72-cell PV Module Cell String Cell String Bypass Diodes Cell String + Bypass diode turns on when the shaded cell(s) can no longer pass as much current as the non-shaded cells.

61 Shade One Cell Example: 72-cell PV Module Cell String Cell String Bypass Diodes Cell String + Bypass diode turns on when the shaded cell(s) can no longer pass as much current as the non-shaded cells.

62 Which shading pattern is worse? 1 2 +

63 I-V Curve of a Partially Shaded String Isc Multiple knees in the I-V curve means multiple peaks in the P-V curve Inverter should track the highest peak Tricky when shading is changing and thus the peaks are changing! Power Current Voltage Voc

64 Shading Myth #2 Myth: Reduction in array output power is proportional to the amount of array area that is shaded. Fact: Shading has a very disproportional impact. Output depends strongly on where the shade falls on a module.

65 Shading one cell string drops 1/3 of PV module voltage and power Shade 2 cells in the same cell-string Single module with 72 cells and 3 bypass diodes

66 The same amount of shade, oriented differently, drops 2/3 of PV module voltage and power. Shade 2 cells in adjacent cell-strings Single module with 72 cells and 3 bypass diodes

67 Shading Myth #3 Myth: Shading from power lines has no effect. Fact: A PV cell s current drops linearly in proportion to the shaded area. Any amount of shading has an effect.

68 Line Shade Narrow Shade on of two series connected modules Voc Isc Vmpp Impp Pmax Shade 98%

69 Line Shade Medium Shade on of two series connected modules Voc Isc Vmpp Impp Pmax Shade % 6 5 5

70 Line Shade Thick Shade on of two series connected modules Voc Isc Vmpp Impp Pmax Shade 77% 1 3 3

71 Edge and Corner Soiling Common in low-tilt arrays Dirty Cleaning the top 90% of module area recovered 50% of the performance. Cleaning the bottom 10% recovered the rest. Clean

72 What is the PV Analyzer all about? Commission and troubleshoot PV arrays faster and better Curve tracing is fast - a single measurement for each string Curve tracing is the most complete performance measurement possible Independently measures each string s max power Built-in PV models give instant performance check Does not require bringing the inverter online Software tool automates data analysis Helps us learn to think like a PV array I V

73 5-Minute PV Analyzer Training Videos

74 Free I-V Curve Poster

75 SolarPro Magazine, Aug/Sep 2011

76 New Tools for PV Array Commissioning and Troubleshooting November 10, 2011 Paul Hernday Applications Engineer cell Bryan Bass R&D Engineer

New Tools for PV Array Commissioning and Troubleshooting

New Tools for PV Array Commissioning and Troubleshooting New Tools for PV Array Commissioning and Troubleshooting June 30, 2011 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 Bryan Bass Sales Engineer bryan@solmetric.com Solmetric Solutions

More information

New Tools for PV Array Commissioning and Troubleshooting

New Tools for PV Array Commissioning and Troubleshooting New Tools for PV Array Commissioning and Troubleshooting Solmetric PVA-600 Megger MIT430 Paul Hernday Applications Engineer paul@solmetric.com cell 707-217-3094 April 5, 2012 Audio is available by telephone

More information

Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software

Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software Introducing the Solmetric PV Analyzer and the New Features of v2.0 PVA Software Next PVA Webinar November 29, 10am PST http://www.solmetric.com/ webinar.html Paul Hernday Senior Applications Engineer paul@solmetric.com

More information

PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer

PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer April 11, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Review of I-V Curves I-V and P-V

More information

PV Array Commissioning and Troubleshooting. Solmetric PV Analyzer

PV Array Commissioning and Troubleshooting. Solmetric PV Analyzer PV Array Commissioning and Troubleshooting with the Solmetric PV Analyzer May 9, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Next webinar: May 30 http://www.solmetric.com/webinar.html

More information

Solmetric PVA-600 PV Analyzer

Solmetric PVA-600 PV Analyzer Introducing the Solmetric PVA-600 PV Analyzer Paul Hernday PV Applications Engineer http://www.solmetric.com/pva600.html Bryan Bass Sales Engineer Topics Introduction to Solmetric Verifying PV array performance

More information

Commissioning and Troubleshooting PV Arrays. Solmetric PV Analyzer

Commissioning and Troubleshooting PV Arrays. Solmetric PV Analyzer Commissioning and Troubleshooting PV Arrays with the Solmetric PV Analyzer November 14, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Topics Review of I-V Curves Introduction

More information

Solmetric White Paper: Winning Contracts with PV Array Testing

Solmetric White Paper: Winning Contracts with PV Array Testing Solmetric White Paper: Winning Contracts with PV Array Testing Contents Introduction...1 Background: I-V Curves in Field Applications...2 What is an I-V curve?...2 Where has I-V curve tracing been used

More information

Analysis and Reporting of I-V Curve Data from Large PV Arrays

Analysis and Reporting of I-V Curve Data from Large PV Arrays Analysis and Reporting of I-V Curve Data from Large PV Arrays Solmetric Webinar December 12, 2013 Paul Hernday Senior Applications Engineer paul@solmetric.com cell 707-217-3094 Goals of I-V Curve Data

More information

Solmetric PVA-1000S Startup Training

Solmetric PVA-1000S Startup Training Solmetric PVA-1000S Startup Training March 22, 2015 Instructor: Paul Hernday Senior Applications Engineer paul@solmetric.com Topics Introduction to the PVA-1000S PV Analyzer Using the software Making I-V

More information

For more information:

For more information: Verify Tab Click on the Verify tab to compare the measured and predicted max power values. Their ratio, in percent, is the Performance Factor. Solmetric PVA-600 PV Analyzer Quick Start Guide History Tab

More information

Field Applications. for I-V Curve Tracers. Silicon PV modules are. By Paul Hernday. I-V Curve Measurements

Field Applications. for I-V Curve Tracers. Silicon PV modules are. By Paul Hernday. I-V Curve Measurements Field Applications for I-V Curve Tracers By Paul Hernday Courtesy Integrated Energy Systems, Pittsburg Unified School District, Sage Renewables, Solmetric, Stellar Energy Solutions While indispensible

More information

Advanced Test Equipment Rentals

Advanced Test Equipment Rentals Established 1981 Advanced Test Equipment Rentals Solmetric PVA-600 PV Analyzer Quick Start Guide www.atecorp.com 800-404-ATEC (2832) : When using the wireless PVA Sensor Kit or manual sensors, the end

More information

Shade Matters. Peter Hoberg Solmetric Corporation

Shade Matters. Peter Hoberg Solmetric Corporation Shade Matters Peter Hoberg Solmetric Corporation Shade Matters Shade s impact on PV production Cell, module, string, array Example measurements Characterizing shade Why measure shade? Shade measurement

More information

Laboratory 2: PV Module Current-Voltage Measurements

Laboratory 2: PV Module Current-Voltage Measurements Laboratory 2: PV Module Current-Voltage Measurements Introduction and Background The current-voltage (I-V) characteristic is the basic descriptor of photovoltaic device performance. A fundamental understanding

More information

Peter Hoberg VP Marketing

Peter Hoberg VP Marketing Peter Hoberg VP Marketing Topics Why measure shade? Important terms and concepts Operating the Solmetric SunEye Resources for more information Why measure shade? Choose optimum location for panels Predict

More information

Upsolar Smart Modules

Upsolar Smart Modules Upsolar Smart Modules Optimized by Energy Improve ROI with No Upfront Cost Smart Modules optimized by Energy deliver more energy, active management and enhanced safety through state-ofthe-art module-embedded

More information

CHAPTER 4 PERFORMANCE ANALYSIS OF DERIVED SPV ARRAY CONFIGURATIONS UNDER PARTIAL SHADED CONDITIONS

CHAPTER 4 PERFORMANCE ANALYSIS OF DERIVED SPV ARRAY CONFIGURATIONS UNDER PARTIAL SHADED CONDITIONS 60 CHAPTER 4 PERFORMANCE ANALYSIS OF DERIVED SPV ARRAY CONFIGURATIONS UNDER PARTIAL SHADED CONDITIONS 4.1 INTRODUCTION The basic configurations have been discussed in the last chapter. It is understood

More information

Application Note: String sizing Conext CL Series

Application Note: String sizing Conext CL Series : String sizing Conext CL Series 965-0066-01-01 Rev A DANGER RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION, AND ARC FLASH This Application Note is in addition to, and incorporates by reference, the installation

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Elgar TerraSAS 1kW-1MW Programmable Solar Array Simulator Simulate dynamic irradiance and temperature ranging from a

More information

PV210. Why buy the PV210?

PV210. Why buy the PV210? The PV210 is a compact & cost effective I-V curve tracer that utilizes NFC technology, eliminating the need for a laptop on site. I-V curve tracing is made fast with simple push button operation; making

More information

Engineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin

Engineering Thesis Project. By Evgeniya Polyanskaya. Supervisor: Greg Crebbin Simulation of the effects of global irradiance, ambient temperature and partial shading on the output of the photovoltaic module using MATLAB/Simulink and ICAP/4 A report submitted to the School of Engineering

More information

Quality Assurance in Solar with the use of I-V Curves

Quality Assurance in Solar with the use of I-V Curves Quality Assurance in Solar with the use of I-V Curves Eternal Sun Whitepaper Written by: RJ van Vugt Introduction I Installers, wholesalers and other parties use performance tests in order to check on

More information

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty

Optional Features. Linear Performance Warranty 10 Years product warranty 25 Years linear performance warranty Those who dream of a better future can help lead to a more meaningful and enriched world. As a leading solar module manufacturer in Korea, we never stop to achieve competitiveness through differentiation,

More information

PV200. Why buy the PV200? The most compact I-V curve tracer around.

PV200. Why buy the PV200? The most compact I-V curve tracer around. The PV200 is a compact & cost effective I-V curve tracer that uses simple push button operation making it an efficient and versatile tester for PV systems. 999 datasets can be stored on the instrument

More information

Traditional PWM vs Morningstar s TrakStar MPPT Technology

Traditional PWM vs Morningstar s TrakStar MPPT Technology Traditional PWM vs Morningstar s TrakStar MPPT Technology Morningstar s MPPT charge controllers use our patented TrakStar advanced control MPPT algorithm to harvest maximum power from a Solar Array s peak

More information

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES

BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES BETTER DESIGN BETTER MATERIALS BETTER PROCESSES BETTER MODULES TM FULL RANGE OF CERTIFIED MODULES Mono Crystalline Watt to 50 Watt Poly (Multi) Crystalline Watt to 80 Watt Glass Cells High Efficiency A-Grade

More information

Performance of high-eciency photovoltaic systems in a maritime climate

Performance of high-eciency photovoltaic systems in a maritime climate Loughborough University Institutional Repository Performance of high-eciency photovoltaic systems in a maritime climate This item was submitted to Loughborough University's Institutional Repository by

More information

Solmetric PV Analyzer

Solmetric PV Analyzer Solmetric PV Analyzer I-V Curve Tracer with SolSensor PVA-1000S, PVA-600 + User s Guide Copyright Solmetric Corporation, 2010 2014 All Rights Reserved. Reproduction, adaptation, or translation without

More information

MC Solarline 2 MC4 pin crimper for 10/12 AWG wire MC Solarline 2 open-end spanner set (2-pack)

MC Solarline 2 MC4 pin crimper for 10/12 AWG wire MC Solarline 2 open-end spanner set (2-pack) Tools Array and Battery Cable Tools PV Cable Assembly Tools Crimp-on PV cable connectors (See Wire and Cable section) require special tools to properly attach the connectors. Single- purpose tools from

More information

Elgar ETS TerraSAS. 1kW-1MW V. Standalone TerraSAS Photovoltaic Simulator

Elgar ETS TerraSAS. 1kW-1MW V. Standalone TerraSAS Photovoltaic Simulator Elgar ETS TerraSAS Standalone TerraSAS Photovoltaic Simulator Low output capacitance High bandwidth up to 30kHz High resolution I-V curve simulates static and dynamic conditions Designed for high speed

More information

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters.

Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters. Keysight Technologies Understanding the Importance of Maximum Power Point Tracking Efficiency for Solar Inverters Application Note 02 Keysight Understanding the Importance of Maximum Power Point Tracking

More information

Dr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece

Dr E. Kaplani. Mechanical Engineering Dept. T.E.I. of Patras, Greece Innovation Week on PV Systems Engineering and the other Renewable Energy Systems. 1-10 July 2013, Patras, Greece Dr E. Kaplani ekaplani@teipat.gr Mechanical Engineering Dept. T.E.I. of Patras, Greece R.E.S.

More information

Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum

Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum Loughborough University Institutional Repository Initial solar cell characterisation test and comparison with a LED-based solar simulator with variable flash speed and spectrum This item was submitted

More information

SOLARONIX. Solixon A-1525-V

SOLARONIX. Solixon A-1525-V SOLARONIX Solixon A-1525-V Based on Solaronix' exclusive light engine, our solar simulation equipment delivers a perfect and continuous artificial sunlight 24/7, allowing for accurate stability and performance

More information

Leading the World in PV Test Solutions

Leading the World in PV Test Solutions seawardsolar.com Leading the World in PV Test Solutions seawardsolar.com/usa The Seaward Solar range of electrical safety test solutions enables PV installers to meet all testing and certification requirements

More information

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof

60 cell LG300N1K-G4. Key Features. High Power Output. Enhanced Performance Warranty. Outstanding Durability. Aesthetic Roof EN LG300N1K-G4 60 cell LG s new module, NeON 2 Black, adopts Cello technology. Cello technology replaces 3 busbars with 12 thin wires to enhance power output and reliability. NeON 2 Black demonstrates

More information

Photovoltaic testing for R&D, DV, and manufacturing

Photovoltaic testing for R&D, DV, and manufacturing Photovoltaic testing for R&D, DV, and manufacturing Neil Forcier Application Engineer Agilent Technologies Jim Freese President Freese Enterprises Inc. www.agilent.com/find/solarcell Page 1 Agenda Introduction

More information

Tel Fax

Tel Fax MAXIMUM POWER POINT TRACKING PERFORMANCE UNDER PARTIALLY SHADED PV ARRAY CONDITIONS Roland BRUENDLINGER ; Benoît BLETTERIE ; Matthias MILDE 2 ; Henk OLDENKAMP 3 arsenal research, Giefinggasse 2, 2 Vienna,

More information

Understanding Temperature Effects on Crystalline PV Modules

Understanding Temperature Effects on Crystalline PV Modules Understanding Temperature Effects on Crystalline PV Modules The following is a discussion on temperature and how it affects solar module voltages and power output. This is particularly important in solar-battery

More information

Maximum Power Point Tracking for Photovoltaic Systems

Maximum Power Point Tracking for Photovoltaic Systems Maximum Power Point Tracking for Photovoltaic Systems Ankita Barange 1, Varsha Sharma 2 1,2Dept. of Electrical and Electronics, RSR-RCET, Bhilai, C.G., India ---------------------------------------------------------------------------***---------------------------------------------------------------------------

More information

Step-By-Step Check Response of PV Module Modeling Tested by Two Selected Power Reference Modules

Step-By-Step Check Response of PV Module Modeling Tested by Two Selected Power Reference Modules From the SelectedWorks of Innovative Research Publications IRP India Winter December 1, 2015 Step-By-Step Check Response of PV Module Modeling Tested by Two Selected Power Reference Modules A. M. Soliman,

More information

Understanding Solar Energy Teacher Page

Understanding Solar Energy Teacher Page Understanding Solar Energy Teacher Page Photovoltaic Power Output & I-V Curves Student Objective The student: will be able to determine the voltage, current and power of a given PV module given the efficiency,

More information

How to Evaluate PV Project Energy Yield

How to Evaluate PV Project Energy Yield How to Evaluate PV Project Energy Yield There are three main characteristics of a PV module that could affect the real energy generation of a PV plant: Temperature coefficient; Low light performance; IAM

More information

ELITE PRO. Automation Components, Inc.

ELITE PRO. Automation Components, Inc. ELITE PRO Automation Components, Inc. FEA TUR E S For single or 3-phase systems using 80-600V phase-to-phase (AC or DC) services when line powered or 0-600V (AC or DC) when externally powered. Measures

More information

1) Solar simulator with I-V measurement setup and software

1) Solar simulator with I-V measurement setup and software Department of Optoelectronics, University of Kerala, Kariavattom, Thiruvananthapuram, Kerala, India 695581, Ph: 91 471 2308167 OPTO/Nanophotonics-Phase II/P-1/2014-15 Quotation Notice Quotations are invited

More information

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT

PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR AN ACCURATE PLOT PLAN IS NECESSARY TO PROCESS YOUR PERMIT PLOT PLAN INSTRUCTIONS ROOF MOUNT SOLAR Building Division 1855 Placer Street, Suite 102 Redding, California 96001 Phone: (530) 225-5761 Fax: (530) 245-6468 Inspection Request Line: (530) 244-5068 Web:

More information

Reference: Photovoltaic Systems, p

Reference: Photovoltaic Systems, p PV systems are comprised of building blocks of cells, modules and arrays to form a DC power generating unit with specified electrical output. Reference: Photovoltaic Systems, p. 115-118 Reference: Photovoltaic

More information

Array. Source-circuit configuration is arguably the most

Array. Source-circuit configuration is arguably the most Array Source-circuit configuration is arguably the most important aspect of PV system design. The electrical and mechanical characteristics of a PV array follow from this fundamental design decision, which

More information

GRID-CONNECTED SOLAR PV SYSTEMS. Design Guidelines for Accredited Installers NO BATTERY STORAGE. January 2013 (Effective 1 February 2013)

GRID-CONNECTED SOLAR PV SYSTEMS. Design Guidelines for Accredited Installers NO BATTERY STORAGE. January 2013 (Effective 1 February 2013) GRID-CONNECTED SOLAR PV SYSTEMS NO BATTERY STORAGE Design Guidelines for Accredited Installers January 2013 (Effective 1 February 2013) These guidelines have been developed by Clean Energy Council. They

More information

Presented in Electrical & Computer Engineering University of New Brunswick Fredericton, NB, Canada The Photovoltaic Cell

Presented in Electrical & Computer Engineering University of New Brunswick Fredericton, NB, Canada The Photovoltaic Cell Presented in Electrical & Computer Engineering University of New Brunswick Fredericton, NB, Canada Introduction The The concept and PVA Characteristics Modeling Operating principles Control strategies

More information

Agenda. 1. Inverter technology. 2. Monitor system. 3. System application. 4. Error Codes and trouble-shooting

Agenda. 1. Inverter technology. 2. Monitor system. 3. System application. 4. Error Codes and trouble-shooting Technical FAQ Agenda 1. Inverter technology 2. Monitor system 3. System application 4. Error Codes and trouble-shooting 2 01 Inverter technology 3 1.1 What s the topology of zeversolar inverters? Single

More information

KIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador

KIT SOLAR ANET O QUÉ INCLUYE? QUÉ PUEDES CONECTAR? Nevera combi. Televisión. 25 Bombillas. Bomba de presión. Cargador KIT SOLAR ANET O 7500 Wh/día QUÉ PUEDES CONECTAR? QUÉ INCLUYE? 9 Módulos FV T RINA SOLAR 255Wp Policristalino (3 Estructuras incluidas) 24 Baterías T URBO ENERGY 8 SOPZS 1400 1 Inversor/cargador/regulador

More information

Quality criteria and certificates

Quality criteria and certificates Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years

More information

CHAPTER 7 MAXIMUM POWER POINT TRACKING USING HILL CLIMBING ALGORITHM

CHAPTER 7 MAXIMUM POWER POINT TRACKING USING HILL CLIMBING ALGORITHM 100 CHAPTER 7 MAXIMUM POWER POINT TRACKING USING HILL CLIMBING ALGORITHM 7.1 INTRODUCTION An efficient Photovoltaic system is implemented in any place with minimum modifications. The PV energy conversion

More information

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets

Type EN180-MS EN185-MS EN190-MS EN195-MS EN200-MS 13.5 A. Container Capacity Multiple Packing 40 feet (GP) 700 pcs / 28 pallets Quality criteria and certificates IEC 61215, IEC 61730, CE-Certification, ISO 9001 and ILB-ISO 14001 Tolerance of nominal power (PMPP) 0+5%; classification range is ±2.5W 10 years product-warranty 5 years

More information

SHORT TECHNICAL DESCRIPTION

SHORT TECHNICAL DESCRIPTION Ioffe Physical-Technical Institute of Russian Academy of Sciences PV Laboratory 26 Polytechnicheskaya str., 194021 St-Petersburg, Russia tel: +7(812) 297-56-49, E-mail: vmandreev@mail.ioffe.ru FOUR-LAMP

More information

In this lab you will build a photovoltaic controller that controls a single panel and optimizes its operating point driving a resistive load.

In this lab you will build a photovoltaic controller that controls a single panel and optimizes its operating point driving a resistive load. EE 155/255 Lab #3 Revision 1, October 10, 2017 Lab3: PV MPPT Photovoltaic cells are a great source of renewable energy. With the sun directly overhead, there is about 1kW of solar energy (energetic photons)

More information

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range

Growatt 2000TL. Input Data Max. DC power Max. DC voltage. PV voltage range MPPT. Full load MPP-Voltage range Growatt 2000TL Maximum efficiency of 97% and wide inpunt voltage range Internal DC switch Transformerless GT topology Compact design Multi MPP controller MTL - String Bluetooth / RF technology / ZigBee

More information

FSEC APPROVAL # XL15-NT

FSEC APPROVAL # XL15-NT AC GEC 4 IN SERIES TO UTILITY METER IN SERIES F-2 35A SW 60A SOLAR MODULE POWER BOX PM-25 270W 2 3 4 JUNCTION BOX 2 7 INVERTER I 6,000W 5 6 3 TO MAIN SERVICE ENTRANCE RE F. MODULES FSEC APPROVAL # XL5-NT90-02

More information

Studies of Shading Effects on the Performances of a Photovoltaic Array

Studies of Shading Effects on the Performances of a Photovoltaic Array Studies of Shading Effects on the Performances of a Photovoltaic Array Mourad Talbi, Nejib Hamrouni, Fehri Krout, Radhouane Chtourou, Adnane Cherif,, Center of Research and technologies of energy of Borj

More information

Development of a GUI for Parallel Connected Solar Arrays

Development of a GUI for Parallel Connected Solar Arrays Development of a GUI for Parallel Connected Solar Arrays Nisha Nagarajan and Jonathan W. Kimball, Senior Member Missouri University of Science and Technology 301 W 16 th Street, Rolla, MO 65401 Abstract

More information

Maintenance Manual LBI-38531G MHz, 110 WATT POWER AMPLIFIER 19D902797G1 DESCRIPTION TABLE OF CONTENTS

Maintenance Manual LBI-38531G MHz, 110 WATT POWER AMPLIFIER 19D902797G1 DESCRIPTION TABLE OF CONTENTS Maintenance Manual LBI-38531G 136-174 MHz, 110 WATT POWER AMPLIFIER 19D902797G1 TABLE OF CONTENTS Page DESCRIPTION.............................................. Front Cover SPECIFICATIONS.................................................

More information

APPENDIX V PRODUCT SHEETS

APPENDIX V PRODUCT SHEETS National Institutes of Health Building 37 Modernization Bethesda, Maryland APPENDIX V PRODUCT SHEETS Katie L. McGimpsey Mechanical Option 1 of 4 BP 4160 160-Watt Monocrystalline Photovoltaic Module The

More information

String Configuration Tool Help!

String Configuration Tool Help! String Configuration Tool Help! (Siento, esto solo está en inglés) 1 Intended Use and Disclaimer Thank you for using the Fronius String Configuration Tool ( FSC Tool ) for North America. Fronius USA provides

More information

Your Origin SLIVER system will be supplied with one of the following sets of panels:

Your Origin SLIVER system will be supplied with one of the following sets of panels: SLIVER3000 Solar System Panel Specifications Your Origin SLIVER system will be supplied with one of the following sets of panels: Manufacturer Mono Or Poly Size (Watts) Panels Required To Achieve Minimum

More information

Abstract. silicon photovoltaic (PV) system on the roof of the Alternative Fuel Vehicle Garage of the

Abstract. silicon photovoltaic (PV) system on the roof of the Alternative Fuel Vehicle Garage of the Abstract CHRISTY, DANIEL WILLIAM. An Experimental Evaluation of the Performance of the Amorphous Silicon PV Array on the NCSU AFV Garage. (Under the direction of Dr. Herbert M. Eckerlin.) A comprehensive

More information

PID: an invisible danger for solar systems and how to prevent it

PID: an invisible danger for solar systems and how to prevent it PID: an invisible danger for solar systems and how to prevent it PV Magazine Quality Roundtable Intersolar, st June Andrea Viaro, Head of Technical Service & Product Mgmt. Europe Total Quality Management.

More information

Simulink Based Analysis and Realization of Solar PV System

Simulink Based Analysis and Realization of Solar PV System Energy and Power Engineering, 2015, 7, 546-555 Published Online October 2015 in SciRes. http://www.scirp.org/journal/epe http://dx.doi.org/10.4236/epe.2015.711051 Simulink Based Analysis and Realization

More information

Photovoltaic Systems I EE 446/646

Photovoltaic Systems I EE 446/646 Photovoltaic Systems I EE 446/646 PV System Types & Goal Types of PV Systems: Grid-tied systems that feed power directly into the utility grid, Residential Systems (1-10kW) Commercial/industrial systems

More information

A Current Sensor-less Maximum Power Point Tracking Method for PV

A Current Sensor-less Maximum Power Point Tracking Method for PV A Current Sensor-less Maximum Power Point Tracking Method for PV System 1 Byunggyu Yu, 2 Ahmed G. Abo-Khalil 1, First Author, Corresponding Author Kongju National University, bgyuyu@kongju.ac.kr 2 Majmaah

More information

CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS

CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS 85 CHAPTER 5 MPPT OF PV MODULE BY CONVENTIONAL METHODS 5.1 PERTURB AND OBSERVE METHOD It is well known that the output voltage and current and also the output power of PV panels vary with atmospheric conditions

More information

Chapter 4. Impact of Dust on Solar PV Module: Experimental Analysis

Chapter 4. Impact of Dust on Solar PV Module: Experimental Analysis Chapter 4 Impact of Dust on Solar PV Module: Experimental Analysis 53 CHAPTER 4 IMPACT OF DUST ON SOLAR PV MODULE: EXPERIMENTAL ANALYSIS 4.1 INTRODUCTION: On a bright, sunny day the sun shines approximately

More information

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates

Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates Impact of Spectral Irradiance on Energy Yield of PV Modules Measured in Different Climates 4th PV Performance Modelling and Monitoring Workshop 22nd and 23rd October, 2015 M. Schweiger TÜV Rheinland Energie

More information

Enhancement of PV Array Performance during Partial Shading Condition

Enhancement of PV Array Performance during Partial Shading Condition Enhancement of PV Array Performance during Partial Shading Condition Ahmed M Mahmoud 1, Salah M Saafan 2, Ahmed M Attalla 1, Hamdy El-goharey 1 Department of Electrical Power and Machines, Ain Shams University,

More information

Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool

Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool Power-One Aurora PLUS and PLUS-HV Series Inverters: guide to the sizing of photovoltaic generators with Aurora Designer and PowerOne String Tool Author: Gianluca Marri Approver: Antonio Rossi Date: 2012/05/03

More information

PV Activity 3 PV Loads

PV Activity 3 PV Loads The purpose of this activity is to investigate the current and voltage output of photovoltaic cells when connected to various loads. This activity includes an optional extra investigation related to power

More information

Photovoltaic Systems Engineering

Photovoltaic Systems Engineering Photovoltaic Systems Engineering Ali Karimpour Assistant Professor Ferdowsi University of Mashhad Reference for this lecture: Trishan Esram and Patrick L. Chapman. Comparison of Photovoltaic Array Maximum

More information

Supplemental Calculation Sheets for Inverter #2

Supplemental Calculation Sheets for Inverter #2 Solar PV Standard Plan Simplified Central/String Inverter Systems for One and TwoFamily Dwellings (10 KW or Less) Supplemental Calculation Sheets for Inverter #2 FORM PV 3S DC Information: Module Manufacturer:

More information

Photovoltaic / Solar Array Simulation Solution

Photovoltaic / Solar Array Simulation Solution PRODUCT BROCHURE Photovoltaic / Solar Array Simulation Solution Keysight s Photovoltaic / Solar Simulation Solution can help you maximize the per formance of your inverter MPPT algorithms and circuits

More information

Power Rating of Multi-junction Solar Cells: Focus Thin Film

Power Rating of Multi-junction Solar Cells: Focus Thin Film Power Rating of Multi-junction Solar Cells: Focus Thin Film Content: 1. Basics of current matching a short review 2. Requirements on Solar Simulator 3. Status of Test labs concerning thin film tandem Prof.

More information

Shading Phenomenon Analysis for a Medium Size 3.8 kw Standalone PV System Connected in Series Parallel Configuration Using MATLAB Simulation

Shading Phenomenon Analysis for a Medium Size 3.8 kw Standalone PV System Connected in Series Parallel Configuration Using MATLAB Simulation International Journal of Applied Engineering Research ISSN 973-6 Volume 1, Number (17) pp. 967-97 Shading Phenomenon Analysis for a Medium Size 3. kw Standalone PV System Connected in Series Parallel Configuration

More information

INSTRUCTION MANUAL. I-V Curve Checker MP-11. Software Version Number: Firmware Version Number: Manual Version Number: 4

INSTRUCTION MANUAL. I-V Curve Checker MP-11. Software Version Number: Firmware Version Number: Manual Version Number: 4 8-3. Main Menu & Monitoring Screen INSTRUCTION MANUAL I-V Curve Checker MP-11 Software Version Number: 01.001 Firmware Version Number: 04.103 Manual Version Number: 4 1. Index 1. Index 1 2. Important User

More information

Operating Manual BENNING PV Link App

Operating Manual BENNING PV Link App Operating Manual BENNING PV Link App ========================================================== Table of contents 1. Registration 2. Start screen 2.1 Functional elements 3. Reading new measurement data

More information

High Power Programmable DC Power Supplies PVS Series

High Power Programmable DC Power Supplies PVS Series Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient

More information

Week 10 Power Electronics Applications to Photovoltaic Power Generation

Week 10 Power Electronics Applications to Photovoltaic Power Generation ECE1750, Spring 2017 Week 10 Power Electronics Applications to Photovoltaic Power Generation 1 Photovoltaic modules Photovoltaic (PV) modules are made by connecting several PV cells. PV arrays are made

More information

FRAX Series Sweep Frequency Response Analyzers

FRAX Series Sweep Frequency Response Analyzers FRAX Series Highest dynamic range and accuracy in the industry Fulfills international standards for SFRA measurements Advanced analysis and decision support built into the software. FRAX 150 with built

More information

Measurement and Monitoring of Performance Parameters of Distributed Solar Panels using Wireless Sensors Network

Measurement and Monitoring of Performance Parameters of Distributed Solar Panels using Wireless Sensors Network Measurement and Monitoring of Performance Parameters of Distributed Solar Panels using Wireless Sensors Network C. Ranhotitogamage, S. C. Mukhopadhyay, S. N. Garratt and W. M. Campbell School of Engineering

More information

Power Rating of Photovoltaic Modules Using a. New Outdoor Method. Meena Gupta Vemula

Power Rating of Photovoltaic Modules Using a. New Outdoor Method. Meena Gupta Vemula Power Rating of Photovoltaic Modules Using a New Outdoor Method by Meena Gupta Vemula A Thesis Presented in Partial Fulfillment of the Requirements for the Degree Master of Science in Technology Approved

More information

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China

Test Report. File No.: SHV04007/15-02 Test Report No.: , P.R. China Applicant... : Manufacturer... : Order No.... : Zhejiang ERA Solar Technology Co., Ltd. Sihai Road, Huangyan Economic Development Zone, Taizhou, Zhejiang 318020, P.R. China Zhejiang ERA Solar Technology

More information

Teacher Page. Understanding Solar Energy. Photovoltaic Power Output & I-V Curves. Student Objective

Teacher Page. Understanding Solar Energy. Photovoltaic Power Output & I-V Curves. Student Objective Understanding Solar Energy Teacher Page Photovoltaic Power Output & I-V Curves Student Objective The student: current and power of a given PV module will be able to determine the size of the array necessary

More information

PV Charger System Using A Synchronous Buck Converter

PV Charger System Using A Synchronous Buck Converter PV Charger System Using A Synchronous Buck Converter Adriana FLORESCU Politehnica University of Bucharest,Spl. IndependenŃei 313 Bd., 060042, Bucharest, Romania, adriana.florescu@yahoo.com Sergiu OPREA

More information

DESIGN AND IMPLEMENTATION OF SOLAR POWERED WATER PUMPING SYSTEM

DESIGN AND IMPLEMENTATION OF SOLAR POWERED WATER PUMPING SYSTEM DESIGN AND IMPLEMENTATION OF SOLAR POWERED WATER PUMPING SYSTEM P. Nisha, St.Joseph s College of Engineering, Ch-119 nishasjce@gmail.com,ph:9940275070 Ramani Kalpathi, Professor, St.Joseph s College of

More information

Evaluating the Effectiveness of Maximum Power Point Tracking Methods in Photovoltaic Power Systems using Array Performance Models

Evaluating the Effectiveness of Maximum Power Point Tracking Methods in Photovoltaic Power Systems using Array Performance Models Evaluating the Effectiveness of Maximum Power Point Tracking Methods in Photovoltaic Power Systems using Array Performance s Anton Driesse Dept. of Electrical Engineering Queen s University Kingston, Ontario

More information

Maximum Power Point (Student Handout) (The Principles of Optimizing Photovoltaic Cell Power Output)

Maximum Power Point (Student Handout) (The Principles of Optimizing Photovoltaic Cell Power Output) Name(s): Maximum Power Point (Student Handout) (The Principles of Optimizing Photovoltaic Cell Power Output) Part 1: Investigating How a Photovoltaic (PV) System Works Take a look at the animation of a

More information

200W Monocrystalline Folding Solar Blanket USER MANUAL PLEASE READ AND UNDERSTAND THE MANUAL AND SAFETY INFORMATION BEFORE USING THE SOLAR BLANKET

200W Monocrystalline Folding Solar Blanket USER MANUAL PLEASE READ AND UNDERSTAND THE MANUAL AND SAFETY INFORMATION BEFORE USING THE SOLAR BLANKET 200W Monocrystalline Folding Solar Blanket USER MANUAL PLEASE READ AND UNDERSTAND THE MANUAL AND SAFETY INFORMATION BEFORE USING THE SOLAR BLANKET SAFETY INFORMATION Keep your solar blanket, Pulse Width

More information

FJB/IFB enclosures Photovoltaic string protection and monitoring enclosures for solar parks from 8 to 32 strings

FJB/IFB enclosures Photovoltaic string protection and monitoring enclosures for solar parks from 8 to 32 strings Enclosed products and solutions FJB/IFB enclosures enclosures for solar parks from 8 to 32 strings new The solution for > High-power photovoltaic installations (large buildings, fields, solar parks ranging

More information

Tools for field testing

Tools for field testing Tools for field testing Gianluca Corbellini - SUPSI October 6 th 2015 1 Agenda 1. Introducing SUPSI 2. Context of PV testing 3. State of the art field testing 4. Procedure for inverter testing 5. Procedure

More information

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0

I n s ta l l at i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0 I n s t a l l a t i o n M a n u a l f o r T E D P r o H o m e T E D P r o L i t e A B C Rev 4.0 IMPORTANT: The installation of your TED Pro Home system is a several-step process. The 1st step is the installation

More information

Performance Evaluation of Solar Home Systems in Hot Climate Condition: mc-si PWM versus a-si MPPT Charge Controller System

Performance Evaluation of Solar Home Systems in Hot Climate Condition: mc-si PWM versus a-si MPPT Charge Controller System ก ก 2 2729 ก ก 2549 Performance Evaluation of Solar Home Systems in Hot Climate Condition: mcsi PWM versus asi MPPT Charge Controller System Wuthipong Suponthana 1, *, Nipon Ketjoy 2, Wattanapong Rakwichian

More information