ADDENDUM INSTALLATION AND OPERATION MANUAL. Option Inverter fans

Size: px
Start display at page:

Download "ADDENDUM INSTALLATION AND OPERATION MANUAL. Option Inverter fans"

Transcription

1 ADDENDUM INSTALLATION AND OPERATION MANUAL

2 Addendum Installation and operation manual INTRODUCTION To achieve a lower noise level while running in cooling mode, the units are equipped with inverter fans. In addition, it is possible to run the unit in low noise mode during periods that the unit can be used with lower cooling capacity and cooling efficiency. For EWYQ units only The low noise mode is not possible while running in heating mode. Input/output menu Ÿ FAN INP/OUTPUTS C1 FANINV.INTERL:OK C1 INV. SP:00Hz FAN INP/OUTPUTS C2 FAN INV.INTERL:OK C2 INV. SP:00Hz To check the status of the fan inverter interlock and to check the inverter frequency setpoint (Hz) of circuit 1. To check the status of the fan inverter interlock and to check the inverter frequency setpoint (Hz) of circuit 2 (only EWAQ130~260 and EWYQ130~250). When the unit is running in normal mode, the fans of the air cooled condenser will be controlled as to achieve a high pressure ranging from 18.9 up to 27.5 bar (EWAQ*/EWYQ*). When the unit is running in low noise mode, the fans of the air cooled condenser will be controlled as to achieve a high pressure ranging from 28.0 up to 35.0 bar (EWAQ*/EWYQ*). NOTE FEATURES OF THE DIGITAL CONTROLLER This chapter gives an overview and a brief functional description of the screens provided by the different menus. Please add this information to the information mentioned in the operation manual. Readout menu ª 0U4 013$ % 012$ % In case more cooling capacity is required during low noise mode, it is possible to lower the high pressure value range, via the service menu. In this case however, noise reduction will be less. To consult actual operational information about the status of the pump, the compressor, the fans, the temperature setpoint (depending on active mode) and to check if the fans are running in low noise mode ( ). SOFTWARE STRUCTURE The software structures mentioned in the operation manual delivered with the unit, must be replaced by the software structures shown in this manual. For EWAQ units, refer to page 3. For EWYQ units, refer to page 5. SELECTING INSTALLATION SITE This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. ADDITIONAL SAFETY MESSAGES CIRCUIT 1 SAFETY CIRCUIT 2 SAFETY 153:FAN INV ERR 253:FAN INV ERR Refer to "Troubleshooting of inverter with the Status display panel" on page 2. C1 ACT. PRESSURES HP1:019$0b = 050$0 LP1:019$0b = -05$2 LOWNOISE:Y FAN1:OFF To consult information about the actual pressures and the fans of circuit 1 and to check if the fans are running in low noise mode. Usersettings menu Å, submenu FAN v FAN LOW NOISE MODE:DAILY SCHEDULE START:22h00 STOP :06h00 To define the schedule timer by entering the start and stop times. Info menu FAN:INV VA:Y 2PUMP:Y HEATERTAPE:Y FAN DO ST:3 DO INV:2 To consult additional information about the unit such as the fan type, Volt Ampere option, presence of a second pump and presence of a heatertape. 1

3 DEFINING THE LOW NOISE MODE The low noise mode can be selected in the usersettings menu Å, sub menu FAN. The low noise mode can be activated in 3 different ways: 1. Through the schedule timer: MODE:DAILY SCHEDULE. Example: START:22h00 STOP :06h00 Low noise TROUBLESHOOTING OF INVERTER WITH THE STATUS DISPLAY PANEL Only a licensed electrician is allowed to carry out an inspection on the status display panel as this inspection requires the switch box to be opened. The operating status of the inverter is indicated by the green and yellow LEDs on the status display panel. These LEDs indicate the following warnings and fault states. Contact your local dealer in case any faults occur. 00h00 06h00 22h00 Fans running in low noise mode Time Through a field installed low noise mode switch. In this case the low noise mode activation is depending on a changeable digital input: MODE:CHANG.DIG.INP. Refer to "Customization in the service menu", chapter "Setting of the changeable digital inputs and outputs" in the installation manual. The changeable digital input must be configured as low noise by selecting LOW NOISE to activate or de-activate the low noise mode. Example: (service menu) DI1 : LOW NOISE 3. Through manual selection: MODE: ACTIVE or MODE: NOT ACTIVE. Green LED Yellow LED R1 - On time 900 msec. R2 - On time 300 msec. Priority Display Drive Status Definitions OFF OFF 1 Mains not present OFF ON 8 Inverter fault - other than the ones listed below ON OFF 13 Inverter running ON ON 14 Ready to run - standby OFF Flashing -R1 4 Fault overcurrent Flashing -R1 OFF 5 Fault overvoltage Flashing -R1 ON 7 Fault motor overtemperature ON Flashing -R1 8 Fault inverter overtemperature Flashing -R1 Flashing -R1 9 Flashing -R1 Flashing -R1 11 Flashing -R1 Flashing -R2 6/10 Flashing -R2 Flashing -R1 12 Flashing -R2 Flashing -R2 2 Flashing -R2 Flashing -R2 3 1 Green LED 2 Yellow LED Warning current limit - Both LEDs are flashing at the same time Other warnings - Both LEDs are flashing alternately Undervoltage trip/undervoltage warning Drive is not ready - Display state >0 ROM failure - Both LEDs are flashing at the same time RAM failure - Both LEDs are flashing alternately 2

4 SOFTWARE STRUCTURE only for EWAQ units ----STARTUP BUSY---- ªÒµ Úæ Ï >READOUT MENU SETPOINTS MENU USERSETTINGS MENU TIMERS MENU HISTORY MENU INFO MENU I/O STATUS MENU LOGIN/LOGOUT MENU NETWORK MENU COOL/HEAT MENU READOUT MENU = ª = SETPOINTS MENU USERSETTINGS MENU = Å TIMERS MENU HISTORY MENU = Ó = INFO MENU = = Ÿ I/O STATUS MENU LOGIN/LOGOUT MENU = Æ NETWORK MENU COOL/HEAT MENU = = Í U % 012$ % COOL. INLSP1:012$0 C1 TEMP.READOUT C2 TEMP.READOUT C1 TEMP.READOUT C2 TEMP.READOUT > COOL. INLSP1:012$0 COOL. INLSP2:012$0 COOL. OUTSP1:007$0 COOL. OUTSP2:007$0 THERMOSTAT THERMOSTAT MODE:INL WATER LOADUP:300s-DWN:030s MANUAL SETTINGS C11:OFF C12:OFF C21:OFF C22:OFF F1*:000% F2*:000% USERSETTINGS MENU >THERMOSTAT COMPRESSOR FAN PUMP FLOATING SETPOINT LANGUAGE TIME AND DATE DICN SERVICE MENU COMPRESSOR FAN PUMP COMPR.LEAD-LAG MODE:PRIORITY PRIORITY: C11>C12>C21>C22 FAN LOW NOISE MODE:DAILY SCHEDULE START:22h00 STOP :06h00 PUMPCONTROL PUMPLEADTIME :020s PUMPLAGTIME :060s DAILY ON:N AT:12h00 COMPR.CAP.LIMIT MODE:LIMIT SETTING SET: C11:OFF C12:OFF C21:OFF C22:OFF FAN FORCED ON IF UNIT IS OFF THEN ALL FANS:OFF DUAL PUMP MODE:AUTO ROTATION OFFSET ON RH :048h GENERAL TIMERS LOADUP:000s-DWN:000s PUMPLEAD :000s FLOWSTOP :00s COMPRESSOR TIMERS GRD11:000s 12:000s AREC11:000s 12:000s M.RT11:000s 12:000s COMPRESSOR TIMERS GRD21:000s 22:000s AREC21:000s 22:000s M.RT21:000s 22:000s FLOATING SETPOINT _ FLOATING SETPOINT MODE:AMBIENT MAXPOS:03$0 NEG:00$0 RF:020$0 SLOPE:006$0 UNIT SAFETY 0F0:EMERGENCY STOP LANGUAGE 0CA:OUT SENSOR ERR 22h33m00s 23/03/06 COOL INLSP1:012$0 1E6:COMPR 1 SAFETY 22h33m00s 23/03/06 COOL. INLSP1:012$0 TIME INFO TIME: 22h05 DATE: WED 24/01/07 UNIT:AW-CO-260 C:SCL CIR:2 EVAP:1 COILC:2 EEV:P REF:R410A FAN:INV VA:Y 2PUMP:Y HEATERTAPE:Y FAN DO ST:2 DO INV:2 SW INFO MAIN:SP1710_055 V2.0 EXT.:SP1559_017 REM.:SP1734_011 DIGITAL INPUTS EMERGENCY STOP :OK FLOWSWITCH:FLOW OK DIG.INP/OUTPUTS HEATER TAPE:OFF PUMPINTERLOCK:CLOSED PUMP:ON DIGITAL INPUTS C1 REV.PH.PROT. :OK C1 HIGH PR.SW. :OK INT.L C11:OK C12:OK DIGITAL INPUTS C1 FAN OVERC.ST1:OK C1 FAN OVERC.ST2:OK C1 FAN OVERC.ST3:NOK DIGITAL INPUTS C2 REV.PH.PROT. :OK C2 HIGH PR.SW. :OK INT.L C21:OK C22:OK DIGITAL INPUTS C2 FAN OVERC.ST1:OK C2 FAN OVERC.ST2:OK C2 FAN OVERC.ST3:NOK LOGIN/LOGOUT MENU LOGIN STATUS:USER LOGOUT? NO LOGIN/LOGOUT MENU CHANGE PASSWORD NEW CONFIRM: 0000 NETWORK COOL. INLSP1:012$0 M:NORMAL CAP:000% SL1:NORMAL CAP:000% SL2:NORMAL CAP:000% SL3:NORMAL CAP:000% SWITCH UNIT ON/OFF TO SWITCH UNIT ON 3

5 C1 ACT. PRESSURES C2 ACT. PRESSURE UNIT STATUS UNIT CAPACITY:000% UNIT STATUS EXTRA READOUT EXTRA READOUT RHP1:00001hP2:00000h TIME AND DATE _ TIME AND DATE TIME: 22h35 DATE FORMAT:DD/MM/YY DATE: MON 20/03/06 EXTRA READOUT EXTRA READOUT EXTRA READOUT _ MODE:AMBIENT SP: 05$0 DIF:01$0 PUMP:ON LEAD:000s DICN _ MASTER SETTINGS MODE:NORMAL OFFSET:0000h PUMP ON IF:UNIT ON PASSWORD NEEDED FOR: SETPOINT MENU:Y UNIT ON/OFF:Y MAIN MENU:GRAPHIC LOGOUT TIMER :05min BUZZER IF SAFETY:YES BACKLIGHT TIME:05min GRAPHIC READOUT:YES SERVICE MENU ENTER SERVICE UNITCAPACITY:000% RHP1:00000hP2:00000h UNIT HISTORY:001 UNIT HISTORY:001 UNIT HISTORY:001 UNITCAPACITY:000% UNIT HISTORY:001 UNIT HISTORY:001 RHP1:00000hP2:00000h UNIT HISTORY:001 UNIT HISTORY:001 COMP. OUTPUTS C11:ON C12:ON C21:ON C22:ON FAN INP/OUTPUTS C1 FANSTEP 1:CLOSED C1 FANSTEP 2:CLOSED C1 FANSTEP 3:CLOSED FAN INP/OUTPUTS C1 FANINV.INTERL:OK C1 INV. SP:00Hz FAN INP/OUTPUTS C2 FANSTEP 1:CLOSED C2 FANSTEP 2:CLOSED C2 FANSTEP 3:CLOSED FAN INP/OUTPUTS C2 FANINV.INTERL:OK C2 INV. SP:00Hz CHANG. DIG. INPUTS DI1 NONE DI2 NONE DI3 NONE CHANG. DIG. INPUTS DI4 NONE DO1 SAFETY+W.(NO) :O DO2 GEN.OPERATION :O CHANG. INP/OUTPUTS DO3 NONE (OPEN) DO4 NONE (OPEN) DO5 NONE (OPEN) CHANG. INP/OUTPUTS DO6 NONE (OPEN) CHANG. INP/OUTPUTS AO1 NONE COMMUNICATION RS232 ONLINE:N RS485 ONLINE:N DIII ONLINE:N 4

6 SOFTWARE STRUCTURE only for EWYQ units ----STARTUP BUSY---- ªÒµ Úæ Ï >READOUT MENU SETPOINTS MENU USERSETTINGS MENU TIMERS MENU HISTORY MENU INFO MENU I/O STATUS MENU LOGIN/LOGOUT MENU NETWORK MENU COOL/HEAT MENU READOUT MENU = ª = SETPOINTS MENU USERSETTINGS MENU = Å TIMERS MENU HISTORY MENU = Ó = INFO MENU = = Ÿ I/O STATUS MENU LOGIN/LOGOUT MENU = Æ NETWORK MENU COOL/HEAT MENU = = Í U % 012$ % COOL. INLSP1:012$0 C1 TEMP.READOUT C2 TEMP.READOUT C1 TEMP.READOUT C11 COIL:000$0 C12 COIL:000$0 C2 TEMP.READOUT C21 COIL:000$0 C22 COIL:000$0 > COOL. INLSP1:012$0 COOL. INLSP2:012$0 COOL. OUTSP1:007$0 COOL. OUTSP2:007$0 THERMOSTAT THERMOSTAT MODE:INL WATER LOADUP:300s-DWN:030s MANUAL SETTINGS C11:OFF C12:OFF C21:OFF C22:OFF F1*:000% F2*:000% USERSETTINGS MENU >THERMOSTAT COMPRESSOR FAN PUMP FLOATING SETPOINT LANGUAGE TIME AND DATE DICN SERVICE MENU COMPRESSOR FAN PUMP COMPR.LEAD-LAG MODE:PRIORITY PRIORITY: C11>C12>C21>C22 FAN LOW NOISE MODE:DAILY SCHEDULE START:22h00 STOP :06h00 PUMPCONTROL PUMPLEADTIME :020s PUMPLAGTIME :060s DAILY ON:N AT:12h00 COMPR.CAP.LIMIT MODE:LIMIT SETTING SET: C11:OFF C12:OFF C21:OFF C22:OFF FAN FORCED ON IF UNIT IS OFF THEN ALL FANS:OFF DUAL PUMP MODE:AUTO ROTATION OFFSET ON RH :048h GENERAL TIMERS LOADUP:000s-DWN:000s PUMPLEAD :000s FLOWSTOP :00s COMPRESSOR TIMERS GRD11:000s 12:000s AREC11:000s 12:000s M.RT11:000s 12:000s COMPRESSOR TIMERS GRD21:000s 22:000s AREC21:000s 22:000s M.RT21:000s 22:000s FLOATING SETPOINT _ FLOATING SETPOINT MODE:AMBIENT MAXPOS:03$0 NEG:00$0 RF:020$0 SLOPE:006$0 UNIT SAFETY 0F0:EMERGENCY STOP LANGUAGE 0CA:OUT SENSOR ERR 22h33m00s 23/03/06 COOL INLSP1:012$0 C11 COIL:000$0 C12 COIL:000$0 C21 COIL:000$0 C22 COIL:000$0 1E6:COMPR 1 SAFETY 22h33m00s 23/03/06 COOL. INLSP1:012$0 C11 COIL:000$0 C12 COIL:000$0 C21 COIL:000$0 C22 COIL:000$0 TIME INFO TIME: 22h05 DATE: WED 24/01/07 UNIT:AW-RH-250 C:SCL CIR:2 EVAP:1 COILC:2 EEV:P REF:R410A FAN:INV VA:Y 2PUMP:Y HEATERTAPE:Y FAN DO ST:2 DO INV:2 SW INFO MAIN:SP1710_055 V2.0 EXT.:SP1559_017 REM.:SP1734_011 DIGITAL INPUTS EMERGENCY STOP :OK FLOWSWITCH:FLOW OK DIG.INP/OUTPUTS HEATER TAPE:OFF PUMPINTERLOCK:CLOSED PUMP:ON DIGITAL INPUTS C1 REV.PH.PROT. :OK C1 HIGH PR.SW. :OK INT.L C11:OK C12:OK DIGITAL INPUTS C1 FAN OVERC.ST1:OK C1 FAN OVERC.ST2:OK C1 FAN OVERC.ST3:NOK DIGITAL INPUTS C2 REV.PH.PROT. :OK C2 HIGH PR.SW. :OK INT.L C21:OK C22:OK DIGITAL INPUTS C2 FAN OVERC.ST1:OK C2 FAN OVERC.ST2:OK C2 FAN OVERC.ST3:NOK LOGIN/LOGOUT MENU LOGIN STATUS:USER LOGOUT? NO LOGIN/LOGOUT MENU CHANGE PASSWORD NEW CONFIRM: 0000 NETWORK COOL. INLSP1:012$0 M:NORMAL CAP:000% SL1:NORMAL CAP:000% SL2:NORMAL CAP:000% SL3:NORMAL CAP:000% COOLING/HEATING MODE:COOLING SWITCH UNIT ON/OFF TO SWITCH UNIT ON 5

7 C1 ACT. PRESSURES C2 ACT. PRESSURES UNIT STATUS UNIT CAPACITY:000% UNIT STATUS EXTRA READOUT EXTRA READOUT C11C:00000h H:00000h RHP1:00001hP2:00000h TIME AND DATE _ TIME AND DATE TIME: 22h35 DATE FORMAT:DD/MM/YY DATE: WED 24/01/07 EXTRA READOUT C12C:00000h H:00000h EXTRA READOUT C21C:00000h H:00000h EXTRA READOUT C22C:00000h H:00000h _ MODE:AMBIENT SP: 05$0 DIF:01$0 PUMP:ON LEAD:000s DICN _ MASTER SETTINGS MODE:NORMAL OFFSET:0000h PUMP ON IF:UNIT ON PASSWORD NEEDED FOR: SETPOINT MENU:Y UNIT ON/OFF:Y MAIN MENU:GRAPHIC LOGOUT TIMER :05min BUZZER IF SAFETY:YES BACKLIGHT TIME:05min GRAPHIC READOUT:YES MANUAL UNIT :OFF CIR1 :OFF CIR2 :OFF MIN. TIME BETWEEN : NORMAL SERVICE MENU ENTER SERVICE UNITCAPACITY:000% C11C:00000h H:00000h RHP1:00000hP2:00000h C12C:00000h H:00000h C21C:00000h H:00000h C22C:00000h H:00000h UNIT HISTORY:001 UNIT HISTORY:001 UNIT HISTORY:001 UNITCAPACITY:000% UNIT HISTORY:001 UNIT HISTORY:001 C11C:00000h H:00000h RHP1:00000hP2:00000h C12C:00000h H:00000h C21C:00000h H:00000h C22C:00000h H:00000h UNIT HISTORY:001 UNIT HISTORY:001 COMP. OUTPUTS C11:ON C12:ON C21:ON C22:ON FAN INP/OUTPUTS C1 FANSTEP 1:CLOSED C1 FANSTEP 2:CLOSED C1 FANSTEP 3:CLOSED FAN INP/OUTPUTS C1 FANINV.INTERL:OK C1 INV. SP:00Hz FAN INP/OUTPUTS C2 FANSTEP 1:CLOSED C2 FANSTEP 2:CLOSED C2 FANSTEP 3:CLOSED FAN INP/OUTPUTS C2 FANINV.INTERL:OK C2 INV. SP:00Hz CHANG. DIG. INPUTS DI1 NONE DI2 NONE DI3 NONE CHANG. DIG. INPUTS DI4 NONE DO1 SAFETY+W.(NO) :O DO2 GEN.OPERATION :O CHANG. INP/OUTPUTS DO3 NONE (OPEN) DO4 NONE (OPEN) DO5 NONE (OPEN) CHANG. INP/OUTPUTS DO6 NONE (OPEN) CHANG. INP/OUTPUTS AO1 NONE COMMUNICATION RS232 ONLINE:N RS485 ONLINE:N DIII ONLINE:N 6

8 Copyright Daikin

INSTALLATION MANUAL. Address card EKAC200A

INSTALLATION MANUAL. Address card EKAC200A INSTALLATION MANUAL Address card 4 1 3 1 2 + GND TX+ TX- 3 29 mm 60 mm 20 mm 2 4 READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO NOT THROW IT AWAY. KEEP IT IN YOUR FILES FOR FUTURE REFERENCE.

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

Installation and User Guide

Installation and User Guide Installation and User Guide User CTS 2 602 manual by Nilan VPM 360 Modbus Version: 3.00 19-10-2016 Software-version: 2.35 The following information describes how to connect to Nilan CTS 602 controls by

More information

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual vacon 100 flow ac drives application manual vacon 1 TABLE OF CONTENTS Document: DPD01083A Version release date: 16.11.12 Corresponds to software package FW0159V121106.vcx 1. Vacon 100 FLOW - Quick Startup

More information

Universal Controller

Universal Controller Universal Controller Overview and Configuration Manual Overview... 1 About this Manual... 1 Introduction... 5 Hardware Overview... 5 Software Overview... 7 Interpreting Flow Diagrams... 8 Foreign Language

More information

Operation. Section 4. Additional Information. Operation 4-1

Operation. Section 4. Additional Information. Operation 4-1 4-1 Section 4 WARNING: Allow only personnel with appropriate training and experience to operate or service the equipment. The use of untrained or inexperienced personnel to operate or service the equipment

More information

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive... CHAPTER KEYPAD OPERATION 3 AND QUICKSTART Contents of this Chapter... The GS1 Digital Keypad................................3 2 LED Display..............................................3 2 Function Keys............................................3

More information

TLC3-BCR-U Series Thermostat

TLC3-BCR-U Series Thermostat OVERVIEW TLC3-BCR-U Series Thermostat Features Low power energy consumption: < 1W per unit Relays switching for outputs each up to 300W Temperature control for 2 or 4-pipe heating or cooling systems. Optional

More information

User manual CLIMATIC 60

User manual CLIMATIC 60 User manual CLIMATIC 60 Providing indoor climate comfort MUL46E-0413 04-2013 Original manual translation TABLE OF CONTENTS AQUALEAN CONTROL MANUAL DISPLAY DC60 INSTALLATION CONNECTION IMPORTANT WARNING

More information

ELECTRONIC THERMOSTAT: T951

ELECTRONIC THERMOSTAT: T951 μnistδt ELECTRONIC THERMOSTAT: T9 One floating output One contact output DESCRIPTION The T9 series thermostats are microcomputer-based, proportional and integral (PI) devices with one floating (incremental)

More information

Modbus Integration Integration for Modbus Functionality for VT8300 Series

Modbus Integration Integration for Modbus Functionality for VT8300 Series Modbus Integration Integration for Modbus Functionality for VT8300 Series Building Management System *For data visualization and analysis Modbus Controller VT8000 Series room controllers 2 TABLE OF CONTENTS

More information

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units

Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units Titan Products RDU-4/TS & RDU-4/5B Time Scheduling Room Display Units 1 Time Scheduling RDU-4/TS - Description of Control Operation The temperature control and time scheduling for the building space is

More information

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps. VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload

More information

13. Before making a service call Trip information and remedies

13. Before making a service call Trip information and remedies . Before making a service call Trip information and remedies.1 Trip causes/warnings and remedies When a problem arises, diagnose it in accordance with the following table. If it is found that replacement

More information

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application

STR-LCF. Security Advice Caution. Notes on Disposal. Electronic Fan Coil Thermostat (Flush mounting) Datasheet. Application STR-LCF Electronic Fan Coil Thermostat (Flush mounting) Datasheet Subject to technical alteration Issue date: 28.2.217 Application The fan coil room thermostat has been designed for individual control

More information

Brief description of KR 15 controllers

Brief description of KR 15 controllers Brief description of KR 15 controllers E N E R G Y R E C O V E R Y Page 2 Page 4 Page 5 Page 6 Page 9 1. Function of the controller 2. Terminal connections 3. Technical data 4. Initial operation 5. Manual

More information

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual vacon 100 flow ac drives application manual PREFACE VACON 3 PREFACE Document ID: DPD01083D Date: 15.10.2014 Software version: FW0159V010 ABOUT THIS MANUAL This manual is copyright of Vacon Plc. All Rights

More information

Fan Coil Actuator FCA 2

Fan Coil Actuator FCA 2 Fan Coil Actuator FCA 2 FCA 2 4920210 Updated: Feb-16 (subject to changes) Page 1 of 89 Contents 1 Function description... 4 1.1 Operation and display... 5 1.2 Advantages of the FCA 2... 6 1.2.1 Special

More information

Fan and Pump AC Inverter

Fan and Pump AC Inverter Fan and Pump AC Inverter Key Features for Fan and Pump Applications PID and Auto Energy Saving Functions. Input Phase Loss and Output Phase Loss Protection. LCD Keypad can be used to copy parameter settings

More information

VFD Reference Guide. In-The-Field Tool

VFD Reference Guide. In-The-Field Tool VFD Reference Guide In-The-Field Tool NXS Basic Speed Control What You Need Drive Type (NXL, NXS) Speed Signal spec Motor nameplate data Signal Type (volts, milliamps) Range (0-10, 2-10; 0-20, 4-20) Navigating

More information

vacon 100 ac drives application manual

vacon 100 ac drives application manual vacon 100 ac drives application manual vacon 0 INDEX Document: DPD00927D Version release date: 5.5.12 Corresponds to software package FW0072V00.vcx 1. Vacon 100 - Startup... 2 1.1 Startup Wizard... 2

More information

Vacon 100 Flow Course

Vacon 100 Flow Course 09-01-2018 Version 18.08F Sw:FW0159V014 Vacon 100 Flow Course Version 18.08F G:\Data\Iedereen\cursussen\Frequentieregelaars\Vacon\Vacon 100 Flow versie 18.08-eng.doc Vacon 100 Flow page1 Index Index...

More information

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6 CHAPTER KEYPAD OPERATION 3 AND QUICKSTART In This Chapter... The GS2 Digital Keypad.....................3 2 LED Display.........................................3 2 LED Indicators.......................................3

More information

NRT 105: Electronic fan-coil controller, equiflex

NRT 105: Electronic fan-coil controller, equiflex Product data sheet 4.04 R 105: Electronic fan-coil controller, equiflex How energy efficiency is improved ECO Meter for displaying the current energy consumption and digital input for the change-over between

More information

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet

AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet AEI800L Avid extreme Liquid Cooled Inverter Module REV 00, March 2016 Avid Controls Inc. 41261 Park 290 Drive, Waller, TX 77484, USA info@avidcontrolsinc.com (+1) (281) 640-8600 Page 1 of 16 Copyright

More information

SPECIFICATION. Online UPS 3000VA

SPECIFICATION. Online UPS 3000VA Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at

More information

1 Digital input (24Vac or dry contact) Inputs

1 Digital input (24Vac or dry contact) Inputs Fan oil Thermostat Fan oil Thermostat Features: Attractive modern look with large LD and backlight Icons driven information and 1 line of text information 2 Pipes Analog, ON/OFF or Floating 4 Pipes Analog,

More information

Enhanced PID for Air Compressors F7 Drive Software Technical Manual

Enhanced PID for Air Compressors F7 Drive Software Technical Manual Software Number: VSF11020X, Drive Models: CIMR-F7UXXXXXX-096 Document Number: TM.F7SW.096, Date: 08/01/05, Rev: 05-08 Enhanced PID for Air Compressors F7 Drive Software Technical Manual This document is

More information

Optidrive Applications Support Library

Optidrive Applications Support Library Optidrive Applications Support Library Application Note Title AN-ODE-2-032 Related Products Optidrive E2 Overview Level 2 PI Closed Loop Feedback Control Applications 1 Fundamental - No previous experience

More information

Operation Manual. Canon CXDI-1 System Digital Radiography

Operation Manual. Canon CXDI-1 System Digital Radiography Canon CXDI-1 System Digital Radiography Operation Manual Before using the instrument, be sure to read this manual thoroughly. Also, read the manuals of other instruments in this system. Keep the manual

More information

Electronic fan speed regulators

Electronic fan speed regulators Electronic fan speed regulators Purpose The fan speed controller maintains the condensing pressure for fan-type condensers or fluid outlet temperatures for dry coolers, within prefixed values, for any

More information

PARAMETER LIST PARAMETER LIST

PARAMETER LIST PARAMETER LIST PRMETER LIST PRMETER LIST dvanced Genset Controller, GC 200 larm list Parameter list Document no.: 489340605L SW version 4.2.x or later GC 200 parameter list 489340605 UK Contents: General information...

More information

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77

theben Fan Coil Actuator FCA 1 Fan Coil Actuator FCA 1 FCA Version: Jan-08 (Subject to change) Page 1 of 77 Fan Coil Actuator FCA 1 FCA 1 492 0 200 Version: Jan-08 (Subject to change) Page 1 of 77 Contents 1 Functional characteristics...4 1.1 Operation and display...5 1.2 Advantages of the FCA 1...5 1.2.1 Special

More information

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz TAC ATV8, IP55 Variable Speed Drives for Asynchronous Motors. -phase. 80/460 V, 50-60 Hz E-60-24 24 May 2004 ATV 8 IP55 drives are specifically designed for pump and fan applications powered by a three-phase

More information

AF91 Adjustable Frequency Drives Series B

AF91 Adjustable Frequency Drives Series B Effective: January, 00 Page New Information AF9 Adjustable Model AF9 Description Model AF9 Adjustable Frequency AC Drives are designed to provide adjustable speed control of -phase motors. These microprocessor-based

More information

Room Controller Thermostat

Room Controller Thermostat ºF / º VAV Thermostat with BAnet ommunication Port Technical Data Inputs Room ontroller Thermostat TROB24T4XYZ1 3 Analog input universal (0-10 Vdc or thermistor or digital input dry contact) 2 Analog outputs

More information

Before you operate the inverter, the parameters that you must first program are the basic parameters.

Before you operate the inverter, the parameters that you must first program are the basic parameters. . Main parameters Before you operate the inverter, the parameters that you must first program are the basic parameters..1 Searching for changes using the history function () : History function History

More information

ADAM-4022T Serial Base Dual Loops PID Controller User s Manual

ADAM-4022T Serial Base Dual Loops PID Controller User s Manual ADAM-422T Serial Base Dual Loops PID Controller User s Manual Warning Message : The ADAM-422T is recommended to be used in general purposed air conditioning application. When using this product in applications

More information

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use Wireless New Products... New Solutions The range of telemetry modules provide remote monitoring and control by radio or twisted-pair wire, over short or long distances. Transducer signals connected at

More information

MITOS VT6 AIR USER MANUAL. 02/10/2015 Manual_MITOS_VT6_AIR_ver3p3_eng

MITOS VT6 AIR USER MANUAL. 02/10/2015 Manual_MITOS_VT6_AIR_ver3p3_eng MITOS VT6 AIR USER MANUAL 02/10/2015 Manual_MITOS_VT6_AIR_ver3p3_eng Summary: GENERAL DESCRIPTION... 3 GENERAL FEATURES... 3 FUNCTIONING PARAMETERS... 4 FUNCTIONING MODE OF THE MITOS VT6 AIR... 7 FUNCTIONING

More information

EN 50178, IEC

EN 50178, IEC Type: DF51 322 1K5 Article No.: 289107 Sales text """Frequency inverter DF51(1,5 kw; 230V) Ordering information Rated voltage U e V Max. rated operational current I e A 7.1 Rated power for motors at 230

More information

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12 INSTRUCTION MANUAL Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS Power Factor Controller A12 1. CONTENTS 1. CONTENTS 1 2. FEATURES 2 3. INSTALLATION, CONNECTION AND APPLYING POWER 2 4.

More information

ATS Controller (KSC-5000) Manual

ATS Controller (KSC-5000) Manual Smart ATS Controller (KSC-5000) Manual ( Modify)March. 03, 2015 Kisung Electric Machinery Co., Ltd. 1 1. The Outline KSC-5000 controls ATS (Automatic Transfer Switch) which is to switch the electric load

More information

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1. safety Doc: DPD00714C, Released: 10.28.2011 vacon 1 This quick guide includes the essential steps for easy installation and setup of your Vacon 10 frequency converter. Before commissioning your drive,

More information

AFC Series AFC -20HG AFC-20SE

AFC Series AFC -20HG AFC-20SE Piezoelectric Feeder Controller AFC Series AFC -20HG AFC-20SE Instruction Manual Thank you for purchasing the controller manufactured by BFC Limited. Please read this instruction manual thoroughly before

More information

Manual. Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description * _0718*

Manual. Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description * _0718* Drive Technology \ Drive Automation \ System Integration \ Services *25835130_0718* Manual Application Inverter MOVIDRIVE modular/system with CiA402 Device Profile Parameter Description Edition 07/2018

More information

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17

Table of Contents. Proximity Sensors. IEC Limit Switches. Encoders. Current Sensors. Section 17 Proximity Section 17 Table of Contents............ 21 2 Application Guide........................ 21 3 ACT Series Transducers......... 21 4 ACTR Series Transducers........ 21 6 ACS150 Series Switches..................

More information

FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE

FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE FCU-503 FAN COIL CONTROLLER WITH RDU-TOUCH INTERFACE BACnet Enabled Description The FCU-503 is designed to provide complete control of fan coil units and / or underfloor heating circuits. The FCU-5 incorporates

More information

ERROR MESSAGES: Click on Error for further detail PROBE ERROR: PROBE IS OPEN OR NOT CONNECTED.

ERROR MESSAGES: Click on Error for further detail PROBE ERROR: PROBE IS OPEN OR NOT CONNECTED. ERR MESSAGES: Click on Error for further detail MOT OVERCURRENT:THE PLATEN HAS BEEN MECHANICALLY RESISTED. MOT ERR: NO ENCODER MESSAGE TO THE MOT SPEED CONTROL IGNITION ERR: after the 4 th failed attempt

More information

LabCon User Manual. Multi-Purpose Temperature Controller Temp High SP

LabCon User Manual. Multi-Purpose Temperature Controller Temp High SP LabCon Basic Multi-Purpose Temperature Controller 42.5 Temp High SP C 42.5 CONTENTS 1. FRONT PANEL LAYOUT 1 2. BASIC OPERATION 2 3. OPERATOR PARAMETERS 5 4. SUPERVISORY PARAMETERS 7 5. FACTORY PARAMETER

More information

You can now configure the information you want to display on the four lines available from the following parameters.

You can now configure the information you want to display on the four lines available from the following parameters. Title: 4-line display features Pag. 1 di 5 You can now configure the information you want to display on the four lines available from the following parameters. - Measured value: current and voltage value.

More information

MultiController E Regulate 24V og 230V

MultiController E Regulate 24V og 230V MultiController E Regulate 24V og 230V Multi-function Controller with Display, Scheduler Function and Modbus interface Software version 2.6 Content: 1 Mounting... 2 1.1 Terminal Connections 24V Version...

More information

YD (MOD A-C) WITH OPTIVIEW CONTROL CENTER FIELD CONTROL MODIFICATIONS

YD (MOD A-C) WITH OPTIVIEW CONTROL CENTER FIELD CONTROL MODIFICATIONS Supersedes: 160.69-PW2 (815) Form 160.69-PW2 (116) WIRING DIAGRAM CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. YD (MOD A-C) WITH OPTIVIEW CONTROL CENTER FIELD CONTROL MODIFICATIONS PURCHASER JOB

More information

vacon 100 hvac ac drives application manual

vacon 100 hvac ac drives application manual vacon 100 hvac ac drives application manual PREFACE VACON 3 PREFACE Document ID: DPD01696K Date: 11.04.2016 Software version: FW0065V032 ABOUT THIS MANUAL This manual is copyright of Vacon Ltd. All Rights

More information

Control solutions Biofloor

Control solutions Biofloor MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital

More information

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1

AQUAVAR CPC. Modbus Communications (Software Version 204 and later)* INSTRUCTION MANUAL ADAQCPC R1 INSTRUCTION MANUAL ADAQCPC R1 AQUAVAR CPC Modbus Communications (Software Version 204 and later)* ADDENDUM TO THE INSTALLATION AND OPERATION MANUAL (IM167) * Aquavar CPC units with software 204 and later

More information

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description. Use of the application program Product family: Product type: Manufacturer: Heating, air conditioning, ventilation Thermostat Siemens Name: Temperature controller UP 237 DELTA i-system Order no.: 5WG1 237-2AB_1

More information

TOSVERT TM VF-nC3 Parameter List

TOSVERT TM VF-nC3 Parameter List TOSVERT TM VF-nC Parameter List E658664 - Setting information * Please fill it in if necessary. Item Content Item Content Setting date / person Customer Application Application model Motor manufacturer

More information

FIELD CONTROL MODIFICATIONS MODEL YS CHILLERS (STYLE E)

FIELD CONTROL MODIFICATIONS MODEL YS CHILLERS (STYLE E) WIRING DIAGRAMS CONTRACTOR ORDER NO. JCI CONTRACT NO. JCI ORDER NO. Supersedes: 60.80-PW5 (999) Form: 60.80-PW5 (5) FIELD CONTROL MODIFICATIONS MODEL YS CHILLERS (STYLE E) PURCHASER JOB NAME LOCATION ENGINEER

More information

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description. Use of the application program Product family: Product type: Manufacturer: Heating, air conditioning, ventilation Thermostat Siemens Name: Temperature controller UP 237 DELTA i-system Order no.: 5WG1 237-2AB_1

More information

CI/SfB (57.7) 1st Edition

CI/SfB (57.7) 1st Edition CI/SfB (7.7) 1st Edition edemand Controllers Electronic voltage controller edemand Controllerss Demand ventilation control for A/C speed controllable Fans Quick start-up by preprogrammed IP4 Rated Total

More information

Table 6.1 Fault Code List Code indication (Note 3)

Table 6.1 Fault Code List Code indication (Note 3) 62 Table 6.1 Fault List UA801 UA802 UA803 UA804 UA805 UA806 UA807 UA808 UA810 UA812 UA813 UA814 UA815 UA817 UA821 AC VOLTAGE OUT OF RANGE AC FREQUENCY OUT OF RANGE AC PHASE ROTATION ERROR OPE. OVER OVER

More information

SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller

SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller SE8600 Series User Interface Guide Rooftop Unit, Heat Pump and Indoor Air Quality Controller Version 10 2 HMI Display The User HMI is configurable and allows display functions such as Date, Time, Outdoor

More information

Wireless Room Thermostat Installation and Operation Y6630D1007

Wireless Room Thermostat Installation and Operation Y6630D1007 Wireless Room Thermostat Installation and Operation Y6630D1007 General safety instructions Contents 1. General safety instructions... 3 1.1. Commissioning the relay module HC60NG... 3 2. Overview... 4

More information

General Specifications

General Specifications General Specifications GS 05F01D01E MODEL UM351 Digital Indicator with Alarms with Active Color PV Display General Model UM351 Digital Indicator with Alarms is a precision alarm instrument provided with

More information

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS

PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS PID500 FULL FEATURED PID TEMPERATURE CONTROLLERS DESCRIPTION FEATURES * Compact Size: 1/16 DIN * Dual LED displays for simultaneous indication of process temperature and set point (Lower display selectable

More information

Adjustable Frequency Drive Fundamentals By Rick Porembski Of The Sandberg Div. of Bornquist.

Adjustable Frequency Drive Fundamentals By Rick Porembski Of The Sandberg Div. of Bornquist. Adjustable Frequency Drive Fundamentals By Rick Porembski Of. Why do we want to do variable speed pumping? Flow Control HVAC systems are designed for worst case situations. Most of the time they have excess

More information

STEP 3: TIME PROPORTIONING CONTROL If you re using discrete outputs for PID control, you will need to determine your time period for the output.

STEP 3: TIME PROPORTIONING CONTROL If you re using discrete outputs for PID control, you will need to determine your time period for the output. APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data

More information

EQJW145. Content: 1 General. 2. Indicators and operating controls 3. Putting into service (by a technician) 4. How to operate (user)

EQJW145. Content: 1 General. 2. Indicators and operating controls 3. Putting into service (by a technician) 4. How to operate (user) SAUER equitherm Electronic heating controller 1) Valid from soft version 09 Content: General 2. Indicators and operating controls 3. Putting into service (by a technician) 4. How to operate (user) en Quick

More information

vacon nx all in one application manual ac drives Phone: Fax: Web: -

vacon nx all in one application manual ac drives Phone: Fax: Web:  - vacon nx ac drives all in one application manual vacon 1 INDEX Document ID:DPD00903A Revision release date: 30.3.2012 1. Basic Application...5 1.1. Introduction...5 1.1.1. Motor protection functions in

More information

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.

1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control. Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)

More information

Laboratory Freezer. Model : LLF-402SR / LLF-403SR / LLF-404SR LLF-403SR-H / LLF-404SR-H

Laboratory Freezer. Model : LLF-402SR / LLF-403SR / LLF-404SR LLF-403SR-H / LLF-404SR-H Operating Manual Number : LLF-405SR Revised : December 1999 August 2007 Laboratory Freezer Model : LLF-402SR / LLF-403SR / LLF-404SR LLF-403SR-H / LLF-404SR-H Promat (HK) Ltd 901 New Trend Centre, 704

More information

Chapter 9: Troubleshooting

Chapter 9: Troubleshooting AFC1500 Operations Manual Chapter 9: Troubleshooting (Rev. 6: 10/09) Chapter 9: Troubleshooting Page 9-1 Chapter 9: Troubleshooting 9.1 Abnormal Conditions. When an abnormal condition is detected by the

More information

Programming Guide. VLT HVAC Drive FC 100

Programming Guide. VLT HVAC Drive FC 100 Programming Guide VLT HVAC Drive FC 100 VLT HVAC Drive Programming Guide Contents Contents 1. How to Program 3 Local Control Panel 3 How to operate the Graphical LCP (GLCP) 3 How to operate the Numeric

More information

Power Regenerative Converter, THYFREC CV240S

Power Regenerative Converter, THYFREC CV240S Development of New Products Power Regenerative Converter, THYFREC CV240S Harmonic restraint, Power regeneration, 120 conduction, Power factor improvement, Common converter system, Environment compatibility

More information

Building Intelligence

Building Intelligence Building Intelligence WORLDWIDE. Inside every building is the potential to reduce energy costs and become more profitable. Walker Wireless helps building owners realize that potential with wireless control

More information

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control NEW FIRMWARE MAKES SETUP A SNAP Application based commissioning allows parameters

More information

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide The Invertek Optidrive E3 Frequency Inverter range is available to order from inverterdrive.com This guide is intended to complement

More information

EFC 3600 Frequency converter for higher energy efficiency and improved process control

EFC 3600 Frequency converter for higher energy efficiency and improved process control EFC 3600 Frequency converter for higher energy eiciency and improved process control 2 Valuable energy used responsibly Rising energy costs and increasing demands on the environmentally sound products

More information

Document code: DPD00343A Edited:

Document code: DPD00343A Edited: vacon 10 ac drives vacon 10 pfc user manual Document code: DPD00343A Edited: 29.4.2010 1.Safety 4 1.1 Warnings 4 1.2 Safety instructions 5 1.3 Grounding and ground fault protection 5 1.4 Before running

More information

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00 NetBiter I/O Extender 4RO 6RTD 8DIO DAIO User Manual Revision 1.00 IntelliCom Innovation AB Linjegatan 3D SE302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 18 21 99 email info@intellicom.se www

More information

Sine Wave Power Inverter GD150/GD300 Series User s Manual

Sine Wave Power Inverter GD150/GD300 Series User s Manual Sine Wave Power Inverter GD150/GD300 Series User s Manual Ver.1.04E Table of Contents 1. Safety Instructions... 3 2. General Information... 4 3. Inverter Features... 5 3-1 Specification...5 3-2 De-rating

More information

The operator interface consists of an LCD and eight keys. Use the interface to program and operate the triggering controller.

The operator interface consists of an LCD and eight keys. Use the interface to program and operate the triggering controller. Nordson Corporation OPERATOR S CARD P/N 1017461C Sure Coat Triggering Controller Operator Interface WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions

More information

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No

Portable Appliance Testers. OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver Code No Portable Appliance Testers OmegaPAT MI 2140 BetaPAT MI 2141 User Manual Ver. 1.2. Code No. 20 750 684 Distributor: Producer: METREL d.d. Ljubljanska 77 SI-1354 Horjul E-mail: metrel@metrel.si http://www.metrel.si

More information

Error codes for REFUsol 012K/016K/020K/024K - UL

Error codes for REFUsol 012K/016K/020K/024K - UL 0 Error management 0x000000 Error was possibly acknowledged although this was not allowed. Else, the error cause cannot be reconstructed. Restart 131074 DC voltage 2 DC link voltage too high: the DC link

More information

M-Max series drives. The next generation of OEM drives

M-Max series drives. The next generation of OEM drives M-Max series drives The next generation of OEM drives Continue learning more about Eaton drives, services and solutions. Please visit us at: www.eaton.com/drives CD CONTENTS MaxConnect MaxLoader Firmware

More information

General Specifications

General Specifications General Specifications GS 0F01D0E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision 1/8 DIN alarm instrument provided with

More information

MRF-2. welba.de. Programmable PID multichannel temperature controller. Installation and operating instructions for plant engineering companies

MRF-2. welba.de. Programmable PID multichannel temperature controller. Installation and operating instructions for plant engineering companies Measuring - Controlling - Regulating All from the same source welba.de Programmable PID multichannel temperature controller MRF-2 Programmable via configuration software WELBA KONSOFT" Installation and

More information

FCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE

FCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE FCU-501 FAN COIL CONTROLLER WITH RDU-4 INTERFACE BACnet Enabled Description The FCU-501 is designed to provide complete control of fan coil units and / or underfloor heating circuits. The FCU-5 incorporates

More information

Technical Manual MDT Air quality/co2 Sensor

Technical Manual MDT Air quality/co2 Sensor 6/2014 Technical Manual MDT Air quality/co2 Sensor SCN MGSUP.01 1 1 Content 1 Content... 2 2 Overview... 4 2.1 Overview Devices... 4 2.2 Usage & Areas of Apllication... 4 2.3 Exemplary circuit diagram...

More information

Model 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR

Model 12200A RCN PTAC/PTHP/FAN COIL CONTROL NODE OPERATION OUTPUTS G1 = FAN 1 G2 = FAN 2 G3 = FAN 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR Model 12200A RCN PTAC/PTHP/ COIL CONTROL NODE OPERATION OUTPUTS G1 = 1 G2 = 2 G3 = 3 O/B = Rev Valve W = HEAT Y = COMPRESSOR Operating Modes Summary (Refer to Logic Tables 1 5): 1. PTAC (Standard) Fan

More information

General Specifications

General Specifications General Specifications GS 0F01D01E Model UM1 Digital Indicator with Alarms with Active Color PV Display General Model UM1 Digital Indicator with Alarms is a precision alarm instrument provided with universal

More information

Product Catalog PRODUCT CATALOG. Power supply system & test equipment

Product Catalog PRODUCT CATALOG. Power supply system & test equipment Product Catalog PRODUCT CATALOG 2018 2018 Power supply system & test equipment. 138/79, Moo 2 Tambon Ban Klang, Amphoe Mueang Pathumthani, Pathumthani Province 12000, Thailand. Tel: +66 21475048-9 Fax:

More information

Electro Controls. Input-Output Modules WattsIndustries.co.uk

Electro Controls. Input-Output Modules WattsIndustries.co.uk Electro Controls Input-Output Modules - 2017 WattsIndustries.co.uk Input-Output Modules Section 08 B.M.S INPUT - OUTPUT MODULES SINGLE AND ADJUSTABLE RELAY ESRM.. Volt free contacts DIN RAIL mounted relay

More information

electrical components

electrical components electrical components solenoid valves for air-cooled machines 4 9090 bin thermostat Gala DP0-40, Pulsar P5-45 909 thermostat for defrosting Gala DP0-70_, Pulsar P45-45 0074 005 90577 thermostat for defrosting

More information

Electronic Controls For general purpose and multi stages controls. Features and Benefits

Electronic Controls For general purpose and multi stages controls. Features and Benefits Refrigeration Controls Catalogue Catalog Section 9 Product Bulletin MS1/4 Electronic Controls For general purpose and multi stages controls Introduction This range of versatile controls is intended for

More information

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866) DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks

More information

EBDSM-PRM Product Guide

EBDSM-PRM Product Guide EBDSM-PRM Product Guide Ceiling PIR presence/absence detector Overview The EBDSM-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual control.

More information

ELECTRONIC THERMOSTAT: T920

ELECTRONIC THERMOSTAT: T920 μnistδt ELECTRONIC THERMOSTAT: T One analog output DESCRIPTION The T series thermostats are microcomputer-based, proportional and integral (PI) devices with one analog 0 to 0 output. They can be used with

More information

Electronic Step Controller

Electronic Step Controller 4 915 Electronic Step Controller, Adjustable switch-on delay (typically used to prevent current surges on startup and after a power failure) Adjustable switch-on points Adjustable switching differential

More information