CI/SfB (57.7) 1st Edition

Size: px
Start display at page:

Download "CI/SfB (57.7) 1st Edition"

Transcription

1 CI/SfB (7.7) 1st Edition

2 edemand Controllers Electronic voltage controller edemand Controllerss Demand ventilation control for A/C speed controllable Fans Quick start-up by preprogrammed IP4 Rated Total motor protection using thermistor connection LCD multi function display Menu language English, German, French, Italian 2 x analogue input for sensors (0-10V separate power supply required, 0-20mA) CO 2 Control Temperature Control Constant Pressure Control Manual remote speed adjuster (0-20 ma) Min/Max speed limitation - Volume range set point adjustment 2 x Programmable relay output - Fault Condition, master slave Programmable 2x Digital inputs On/Off, external fault, Manual speed control RS48 Modbus Interface Master/Slave capability via 0-10V output Equipment/Function Mains switch with by-pass function Pin protection, to save user settings Quick start up by pre-programmed Max environmental conditions 40 Deg C, 8% Humidity no condensation Readout events memory (checking Fault log) Technical Line voltage 1~ 20V (-1% / + 10%) 0/60 Hz Line Voltage ~208V - 41V (-10%/+6%), 0/60 Hz Part No Voltage 1 Phase 1 Phase Phase Phase Phase Rated current / A Max. line fuse / A Max. heat dissip. /W Weight / kg Interference emissions EN (unshielded motor cable) Interference immunity EN Phase 6 Amp Phase 10 Amp Ø 1.Ø Phase /10 /1 Amp 2 T:

3 edemand Controllers Frequency Inverter 1~ to ~ edemand Controllerss Demand ventilation control for A/C speed controllable Fans Quick start-up by preprogrammed IP4 Rated Total motor protection using thermistor connection Equipment/Function Pin protection, to save user settings Quick start up by pre-programmed Integrated SINEFILTER Max environmental conditions 40 Deg C, 8% Humidity no condensation Ø LCD multi function display Menu language English, German, French, Italian 2 x analogue input for sensors (0-10V separate power supply required, 0-20mA) CO 2 Control Temperature Control Constant Pressure Control Manual remote speed adjuster (0-20 ma) Min/Max speed limitation - Volume range set point adjustment Readout events memory (checking Fault log) Speed control of fans without additional (electromagnetic) motor noise Parallel operation of fans, no risk of motor damage (screened motor cables are not required) Active power factor adjustment for sinusoidal input current Integrated process controller (PID free programmable) 1 Phase 6 Amp 2 x Programmable relay output - Fault Condition, master slave Programmable 2x Digital inputs On/Off, external fault, Manual speed control RS48 Modbus Interface Master/Slave capability via 0-10V output Technical Line voltage 1~ V (-10 % / +10 %), 0/60 Hz Output voltage ~20V (max. 20V) for ~ motors in connection Part No Voltage 1 Phase Rated current / A 6 Max. line fuse / A 10 Max. heat dissip. /W 20 Weight / kg 6.6 Max output Frequency 100 Hz Clock frequency 16 Hz Interference emissions EN (unshielded motor cable) Interference immunity EN W:

4 edemand Controllers Frequency Inverter ~ edemand Controllerss Demand ventilation control for A/C speed controllable Fans Quick start-up by preprogrammed IP4 Rated Total motor protection using thermistor connection Equipment/Function Pin protection, to save user settings Quick start up by pre-programmed Integrated SINEFILTER Max environmental conditions 40 Deg C, 8% Humidity no condensation LCD multi function display Menu language English, German, French, Italian 2 x analogue input for sensors (0-10V separate power supply required, 0-20mA) CO 2 Control Temperature Control Constant Pressure Control Manual remote speed adjuster (0-20 ma) Min/Max speed limitation - Volume range set point adjustment 2 x Programmable relay output - Fault Condition, master slave Readout events memory (checking Fault log) Speed control of fans without additional (electromagnetic) motor noise Integrated SINEFILTER between phase to phase & phase to ground Parallel operation of fans, no risk of motor damage (screened motor cables are not required) Active power factor adjustment for sinusoidal input current Integrated process controller (PID free programmable) 2. Amps /8/14/18 Amps.Ø 6.Ø Programmable 2x Digital inputs On/Off, external fault, Manual speed control RS48 Modbus Interface Technical Line voltage ~ V (-1 % / +10 %), 0/60 Hz Master/Slave capability via 0-10V output Part No Rated current / A Max. line fuse / A Max. heat dissip. /W Weight / kg Max output Frequency 100 Hz Clock frequency 16 Hz Interference emissions EN (unshielded motor cable) Interference immunity EN T:

5 edemand Controllers Frequency Inverter 1~ edemand Controllerss Demand ventilation control for A/C speed controllable Fans Quick start-up by preprogrammed IP4 Rated Total motor protection using thermistor connection LCD multi function display Menu language English, German, French, Italian 2 x analogue input for sensors (0-10V separate power supply required, 0-20mA) CO 2 Control Temperature Control Constant Pressure Control Manual remote speed adjuster (0-20 ma) Min/Max speed limitation - Volume range set point adjustment 2 x Programmable relay output - Fault Condition, master slave Programmable 2x Digital inputs On/Off, external fault, Manual speed control RS48 Modbus Interface Master/Slave capability via 0-10V output Equipment/Function Pin protection, to save user settings Quick start up by pre-programmed Integrated SINEFILTER Max environmental conditions Deg C, 8% Humidity no condensation Readout events memory (checking Fault log) Speed control of fans without additional (electromagnetic) motor noise Parallel operation of fans, no risk of motor damage (screened motor cables are not required) Active power factor adjustment for sinusoidal input current Integrated process controller (PID free programmable Technical Line voltage 1~ V (-10 % / +10 %), 0/60 Hz Part No Voltage 1 Phase 1 Phase 1 Phase Rated current / A rated Current/ A Amps /10 Amps 240.Ø Ø 19. Max. line fuse / A Max. heat dissip. /W Weight / kg Max output Frequency 100 Hz Clock frequency 16 Hz Interference emissions EN (unshielded motor cable) Interference immunity EN W:

6 edemand Auto Changeover Panels IP4 Enclosure edemand compatible Single & Three Phase models Adjustable Duty/Share Timer Automatic Changeover (Fan Fail) Fan Failure Alarm contacts Offering Demand Ventilation control for the wide range of standard AC speed controllable Twin fans, these new changeover panels have been designed to compliment the new range of edemand Controllers and are fully compatible. Speed control input is suitable for use with the following edemand Controller ranges Single & Three Phase electronic speed controllers. Single & Three Phase inverters. Single to Three Phase inverter. Models Stock Ref Three Phase 10 Amp Single Phase 10 Amp Single Phase 20 Amp Connection Diagrams Single Phase Inverters for , & Auto % L1 L1 N N U1 U1 U2 U K1 K2 PE Line L1 N 1 ~ V 0/60 Hz ~ Motor with internal thermostats 2 Contact rating max. 2 A / 20 V AC 8 Switch or Jumper 7 Addressing C C Normal V V V ma ma E1.1 E2.1 D- E1 E2 E1.2 E2.2 C D+ GND ma 24 V TB / TP Digital Analog24V DC Analog Analog Digital In In 1 Out 1 Out In 1 In 2 In GND TK/PTC D1 D1 A GND24 V24 VE1 GNDE2 GNDD2 D2 K1 K2 L1 L2 L N U V W PE U1 U2 TB TB M 1~ 6 Contact rating max. AC 20 V 2 A 1 Line 1 ~ V, 0/60 Hz 2 1 ~ Motor with internal thermostats Output V (Imax = 6 ma) 4 1: V, ma, ma, TF.. (KTY81-210), PT1000 TB TB D- D+ GND Digital In 1 Digital In 2 Analog Analog Analog Out 1 In 1 Analog Temp Out 2 In 2 1/2 24V D1 D2 A1 A2 E1 E2 T1 24V D1 D2 GND GND GND GND T2 GND V ma ma Output V V ma (Imax = 6 ma) ma 4 TF.. TF.. Three Phase Inverters for , 44417, , & Addressing 7 Normal KTY PT : V, ma, ma, TF.. (KTY81-210), PT Contact rating max. 2A / 20 V AC 7 Addressing, normal lock closed 24 V Data Data GND+ - RS mm² / 2x PE L1 L2 L N 1 Line ~ V 0/60 Hz Only in special version suitable for IT network! U V WPE M ~ Y/ TB TB ~ Motor with internal thermostats 1 Line ~ V, 0/60 Hz 2 Only in special version suitable for IT network! ~ Motor with internal thermostats 4 Output V (I max = 10 ma) 1: V, ma, ma, TF.. (KTY) 6 2: V, ma, ma, TF.. (KTY) 7 Addressing, normal lock closed 8 Switch or jumper depending on version Output V V (Imax= 10 ma) ma ma 4 TF.. (KTY) V ma ma TF.. (KTY) 0-10 V TF.. MBG..-I DSG 0-10 V MAL 0-10 V A E1 GND 0-10 V E1 GND 24V E1 GND 24V E1 GND 24V E1 GND TF.. 10 k 1 BN GN BN YE WH 1 2 MBG.. DSG.. MAL1/10 (4-20 ma) (0-10 V) (0-10 V) 24 V Data Data GND+ - RS-48 GNDD+ D- Terminal AXG-1A(E) 6 T:

7 Accessories & Controls Connection Diagrams Single Phase Electronic for & F1=M10 A /...10 F1=FF20 A Auto % C ma V PE PE N N L1 6 E2 E1 Contact rating max. AC 20 V A Digital In 1 L1 U1 U1 U2 U V D (TB) (TB) D (E) D1 K1 K2 Analog Out 1 D1 (GND) A1GND Digital In 2 Analog In 2 Analog In 1 A (D2) GND (D2) E2GNDE1GNDGND 24V GND D+D- PE N L1 Line depending on version 1 ~ 20 V 0/60 Hz or 1 ~ 11 V 0/60 Hz 1 PE U1 U2TB TB M 1~ 1 ~ Motor with internal thermostats 2 1 Line voltage depending on version: 1 ~ 20 V, 0/60 Hz or 1 ~ 11 V, 0/60 Hz 2 1 ~ Motor with internal thermostats Output V (Imax = 10mA) 4 2: V, ma, ma, TF.. (KTY) 1: V, ma, ma, TF..(KTY) 6 Contact rating max. AC 20 V A 0-10 V TF.. MBG..-I A E1 GND 0-10 V E1 GND 24VE1 TF.. 10 k 1 BN GN MBG.. (4-20 ma) V ma ma TF..(KTY) Output V V (Imax = 10 ma) ma ma TF..(KTY) DSG 0-10 V MAL 0-10 V GND 24V E1 GND 24VE1 GND BN YE WH DSG.. (0-10 V) 1 2 MAL1/10 (0-10 V) 24 V Data Data GND + - RS-48 Three Phase Electronic for , & W: 7

8 By Appointment to H.M. The Queen Suppliers of Unit Ventilation Equipment Vent-Axia, Crawley, West Sussex VENT-AXIA CONTACT NUMBERS Free technical, installation and sales advice is available Sales Centre: Domestic & Commercial Sales Tel: Sales Fax: Tech Support Tel: Tech Support Fax: Industrial Sales Tel: Sales Fax: Tech Support Tel: Tech Support Fax: Web: Supply & Service All sales made by Vent-Axia Limited are made only upon the terms of the Company s Conditions of Sale, a copy of which may be obtained on request. As part of the policy of continuous product improvement Vent-Axia reserves the right to alter specifications without notice. 400/1110

EN 50178, IEC

EN 50178, IEC Type: DF51 322 1K5 Article No.: 289107 Sales text """Frequency inverter DF51(1,5 kw; 230V) Ordering information Rated voltage U e V Max. rated operational current I e A 7.1 Rated power for motors at 230

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

SPEED CONTROL OPTIONS

SPEED CONTROL OPTIONS SPEED CONTROL OPTIONS Product name Stouch External 10 kω Frequency signal ETY MTY TGRV (1f) TGRT (3f) potentiometer inverters 0-10 VDC VKA EKO + + + + VKAP 3.0 + + + AKU EKO + + + + AKU + + + VKS/VKSA

More information

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS S E N S O R S PROGRAMMABLE SENSOR CONTROLLER TX9044 COMPLETE VERSATILITY OF SENSOR MANAGEMENT & DATA COMMUNICATIONS Analogue sensors, temperature devices, frequency inputs and digital sensors direct fingertip

More information

Fan and Pump AC Inverter

Fan and Pump AC Inverter Fan and Pump AC Inverter Key Features for Fan and Pump Applications PID and Auto Energy Saving Functions. Input Phase Loss and Output Phase Loss Protection. LCD Keypad can be used to copy parameter settings

More information

Analogue temperature controllers

Analogue temperature controllers Analogue temperature controllers CT8A Input by J-K thermo-couple or by thermo-resistance Pt 00 (-wire) regulation modes : ON/OFF or proportional derivative selected by wiring Relay output Specifications

More information

PROCESS & TEMPERATURE CONTROLLERS

PROCESS & TEMPERATURE CONTROLLERS PROCESS & TEMPERATURE CONTROLLERS NOVA PD54 Series Thermocouple, RTD, & Process Inputs High Accuracy Auto-Tuning PID Heating & Cooling Models Universal Power Supply 1-24 VAC Up to 3 Relays & 2 Analog Outputs

More information

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet RG56-AG7- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 746 Mulfingen Phone: +49 798 - Fax: +49 798 - www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG56-AG7- MG-FF Phase ~ Nominal voltage

More information

CT325 Miniature DC Temperature Controller

CT325 Miniature DC Temperature Controller CT325 Miniature DC Temperature Controller Overview The CT325 Miniature DC Temperature Controller is designed for use with Minco Thermofoil heaters and RTD or thermistor sensors. It offers inexpensive on/off

More information

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet RG6-AB6- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 6 Mulfingen Phone: + 798 8- Fax: + 798 8- www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG6-AB6- MG-IF Phase ~ Nominal voltage [VAC]

More information

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet

High-efficiency Circulator Pump. Rio-Eco N / Rio-Eco Z N. Type Series Booklet High-efficiency Circulator Pump Rio-Eco N / Rio-Eco Z N Type Series Booklet Legal information/copyright Type Series Booklet Rio-Eco N / Rio-Eco Z N All rights reserved. The contents provided herein must

More information

EC centrifugal fan. backward curved, single inlet

EC centrifugal fan. backward curved, single inlet RG4-AM56- ebm-papst Mulfingen GmbH & Co. KG Bachmühle 746 Mulfingen Phone: +49 8 8- Fax: +49 8 8- www.ebmpapst.com info@de.ebmpapst.com Nominal data Type Motor RG4-AM56- MG-EA Phase ~ Nominal voltage [VAC]

More information

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS

control & display PROGRAMMABLE SENSOR CONTROLLER COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS PROGRAMMABLE SENSOR CONTROLLER TX9042 COMPLETE VERSATILITY OF UNDERGROUND SENSOR MANAGEMENT & DATA COMMUNICATIONS ATEX Gas sensors, flow sensors, pressure sensors, vibration monitoring, temperature devices,

More information

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE 1 2 SERIES 1 2 pag. 4 pag. 5 Applications Model identification 3 pag. 5 4 pag. 6 Capacity

More information

CONTROL MANUAL. Dry-Pic 09PE - 09VE

CONTROL MANUAL. Dry-Pic 09PE - 09VE CONTROL MANUAL Dry-Pic 09PE - 09VE Translation of the original document 003, 04.01 EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth

More information

RE92. CHECKMATE. Dual loop controller for industry purpose.

RE92. CHECKMATE. Dual loop controller for industry purpose. ! " # $ % & & ( ) * +. 0 1 2 3 4 5 8 9 6 : 7 ; * < + = >? @. A B C 0 D 1 E F G H 2 D I J 3? RE92. CHECKMATE. Dual loop controller for industry purpose. Simple and userfriendly service Safety and reliability

More information

Advanced, accurate and intelligent monitoring for your transformer

Advanced, accurate and intelligent monitoring for your transformer QUALITROL 505 ITM Intelligent transformer monitor Advanced, accurate and intelligent monitoring for your transformer The power to know your transformer health immediately with TransLife Advanced thermal

More information

Control solutions Biofloor

Control solutions Biofloor MR24 Central radio controller 24V Connect COMAP offers the Connect control system as part of its underfloor heating and cooling solution. Composed of a central radio control module (MR24), wireless digital

More information

FDU50 Frequency inverters 018 to 037 (S2) FDU50 Frequency inverters 046 to 060 (X2)

FDU50 Frequency inverters 018 to 037 (S2) FDU50 Frequency inverters 046 to 060 (X2) Datasheet FDU50 FDU50 Frequency inverters 018 to 037 (S2) Type number FDU50-018 -026-031 -037 Rated power kw 11 15 18.5 22 Rated output current A,RMS 18 26 31 37 Current limit I CL, 60s A,RMS 22 31 37

More information

General Purpose AC Drives

General Purpose AC Drives General Purpose AC Drives AC Drive 0.25k - 7.5k Description hether you need to control a conveyor belt, automatic barrier, machine spindle or other general purpose application, the AC650 delivers reliable,

More information

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20 SMART SERIES CODING SYSTEM FOR AV ACTUATOR WIRING DIAGRAMS There are 3 elements to the wiring codes used in AVA electric actuators: WIRING CODE 1 3 Wire system, single pole double throw, switching the

More information

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview Overview Design The complete flowmeter consists of a flow sensor and an associated transmitter from the Transmag 2 for pulsed alternating field. These are available as remote and compact versions ( 911/E

More information

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse ADJUSTABLE SPEED DRIVES W7 Series 18 Pulse Meets or Exceeds Your Specifications Standard Specifications Item Voltage Class 460V Maximum HP 60 75 100 125 150 200 250 300 400 500 600 700 800 Drive Rating

More information

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485

nd30 EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS Ethernet www/ ftp Modbus TCP Modbus RS-485 cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement and recording of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase

More information

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05 PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES ECE R10-05 Kert is always ready to help you! If you need: Advices

More information

This Chapter contains:

This Chapter contains: 7 This Chapter contains: Table 7.1 Table 7-2 Table 7-3 Table 7-4 contains the general technical specifications for the MICROMASTER 430 inverter contains terminal tightening torques and the required cooling

More information

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS

new! nd30 - METER OF POWER NETWORk PARAMETERS EXAMPlE OF APPliCATiON MEASUREMENT AND ViSUAliZATiON OF POWER NETWORk PARAMETERS new! cat iii Electrical Safety nd30 - METER OF POWER NETWORk PARAMETERS Measurement of power network parameters in 3- or 4-wire balanced and unbalanced systems. Color graphic display: lcd TFT 3,5, 320

More information

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical specifications - Installation rules - Electrical connections - Modbus connection rules - DIP-switches settings -

More information

Conductivity Analyzer

Conductivity Analyzer Data Sheet Conductivity Analyzer Comprehensive range of field-proven conductivity cells satisfies broad range of applications. Comprehensive diagnostics facility with in-built software protection ensures

More information

Frequency inverters DF Vector frequency inverters DV

Frequency inverters DF Vector frequency inverters DV Contents 15/1 DF DV allow an infinitely variable speed control of three-phase motors through the continuous control of the voltage/frequency ratio (U/f inverter) or through sensorless flow control (vector

More information

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. REGULATION AUTOMATIC SYNCHRONIZER for GENERATOR NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds

More information

AEROCONNECT 1B NA C Control manual

AEROCONNECT 1B NA C Control manual AEROCONNECT 1B NA 11.3 C 03-01 Control manual EN CONTENTS PAGE 1 - IMPORTANT RECOMMENDATIONS 1.1 Power supply 1. Electronic board specifications 1.3 Caution 1.4 Earth 1. Sensor connections 1.6 Communication

More information

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator REGULATION Automatic Synchronizer for Generator NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function. NPRG870 adds

More information

About AB Industrietechnik

About AB Industrietechnik About AB Industrietechnik AB Industrietechnik Srl has been manufacturing for over 30 years control equipment and measuring instruments for all the measurable parameters in the field of thermo technical

More information

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20

STANDARD WIRING DIAGRAMS FOR SMART MODEL 20 CODING SYSTEM FOR AV ACTUATOR WIRING DIAGRAMS There are 3 elements to the wiring codes used in AVA electric actuators: WIRING CODE 1 3 Wire system, single pole double throw, switching the live SPDT 2 3

More information

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals Accessories High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals WIKA data sheet AC 80.03 Applications Machine building

More information

The new Yaskawa Varispeed G7 Inverter

The new Yaskawa Varispeed G7 Inverter The new Yaskawa Varispeed G7 Inverter Unique new 3-level PWM flux vector Constant or variable torque applications control method 0.4 kw to 300 kw power range Exceptional low speed/high torque control Quick

More information

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters RI-F200 Series Single and Three Phase Multifunction Energy Meter DIN 96 panel mounted -/1A or -/5A current transformer input Single phase or three phase network compatible Programmable voltage and current

More information

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w)

Current consumption ma solenoid current consumption ( max 300 ma) Hz % V ma. Housing dimensions mm 120(d) x 99(h) x 23(w) 89 610/112 ED EWM-A-SV ANALOG AMPLIFIER CARD SERVOVALVE CONTROL RAIL MOUNTING TYPE: DIN EN 50022 OPERATING PRINCIPLE This card is designed for a dynamic control of servovalves with the current output controlled

More information

Siemens AG ED CB00-0BA0 6ED HB00-0BA0 6ED MB00-0BA1 6ED FB00-0BA1 Supply voltages Rated value

Siemens AG ED CB00-0BA0 6ED HB00-0BA0 6ED MB00-0BA1 6ED FB00-0BA1 Supply voltages Rated value Siemens AG 008 Overview Expansion modules for the connection to LOGO! Modular With digital inputs and outputs, analog inputs or analog outputs Technical specifications 1CB00-0BA0 1HB00-0BA0 1MB00-0BA1

More information

NX Series Inverters. HVAC Pocket Programming Guide

NX Series Inverters. HVAC Pocket Programming Guide NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product

More information

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X KOBO-pH Transmitter for ph-value and ORP Model APM-X measuring monitoring analysing EXPERT-LINE Measuring range: ph value: 0 to 14 ORP: -1500 to +1500 mv (0-100%) For general-purpose use with: Analogue

More information

PowerFlex 400 AC Drive Guide Specification

PowerFlex 400 AC Drive Guide Specification PowerFlex 400 AC Drive Guide Specification Adjustable Frequency Drives 3.0 50HP @ 200 to 240V AC 3.0 350HP @ 380 to 480V AC PART 1 GENERAL 1.01 Quality Assurance A. The manufacturer shall have minimum

More information

Digital indicator for panel mounting With multi-function input Model DI25

Digital indicator for panel mounting With multi-function input Model DI25 Accessories Digital indicator for panel mounting With multi-function input Model DI25 WIKA data sheet AC 80.02 Applications Plant construction Machine tools Plastics technology and processing Ventilation

More information

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions ELECTRONIC SPEED CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I Harmonics Temperature input Measurement accuracy 0.5 Memory 4 MByte UMG 104 Energy measurement device for DIN rails Communication Profibus (DP / V0 optional) Modbus RTU Power quality Harmonics up to 40th

More information

Specification DataFile

Specification DataFile DATUM U & U Ultrasonic Level System Specification DataFile 6-digit backlit l.c.d. and bargraph clear display of measured level Echo Processing using 'DATEM' software true level measurement, overcoming

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks Threshold value monitoring Pulse outputs UMG 96L / UMG 96 Universal measurement device Measuring accuracy Energy: Class 2 Current.../1 A,.../5 A Voltage L - N: ± 1 % Networks TN-, TT-Networks 2 digital

More information

* _1116* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Explosion-Proof Servomotors CMP40 63, CMP.

* _1116* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Explosion-Proof Servomotors CMP40 63, CMP. Drive Technology \ Drive Automation \ System Integration \ Services *23069317_1116* Revision Explosion-Proof Servomotors CMP40 63, CMP.71 100 Edition 11/2016 23069317/EN SEW-EURODRIVE Driving the world

More information

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP) Data Sheet Analyze IT Single and Dual Input Analyzers for ph/redox (ORP) Cost effective select from two input ph/redox (ORP) or combined ph/redox (ORP) and conductivity in one analyzer High functionality

More information

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID RI-D140 Three Phase Multifunction DIN Rail Energy Meter (MID Certified) Four module DIN rail mounted Energy pulse LED True RMS measurement Cost effective and accurate Modbus communication -/1A or -/5A

More information

vacon 100 flow ac drives application manual

vacon 100 flow ac drives application manual vacon 100 flow ac drives application manual vacon 1 TABLE OF CONTENTS Document: DPD01083A Version release date: 16.11.12 Corresponds to software package FW0159V121106.vcx 1. Vacon 100 FLOW - Quick Startup

More information

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung Dimension diagrams All dimensions in mm 73 mm 10 mm 35 mm 44 mm 90 mm 90 mm 107,5 mm 50 mm 76 mm 82 mm Front view Side view Typical connection An. In R32 RS485 Dig. I/O Versorgungsspannung Auxiliary Supply

More information

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800

NOVOHALL Rotary Sensor non-contacting. Series RSC-2800 NOVOHALL Rotary Sensor non-contacting Series RSC-2800 Special features Non-contacting, magnetic technology Measuring range up to 360 Available with push-on coupling or marked shaft Simple mounting Protection

More information

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse ADJUSTABLE SPEED DRIVES HX7 Series 18-Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion

More information

Frequency Converter Fv vector control converters for universal applications

Frequency Converter Fv vector control converters for universal applications Frequency Converter Fv vector control converters for universal applications 2 Our goal: To be world market leader in providing benefits to customers With our broad portfolio of products and services we

More information

SPECIFICATION. Online UPS 3000VA

SPECIFICATION. Online UPS 3000VA Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at

More information

Electric thrust actuator. Electric thrust actuator ARI-PREMIO -Plus 2G. 2,2-5 kn. Electric thrust actuator. ARI-PREMIO -Plus 2G kn.

Electric thrust actuator. Electric thrust actuator ARI-PREMIO -Plus 2G. 2,2-5 kn. Electric thrust actuator. ARI-PREMIO -Plus 2G kn. ARI-PREMIO -Plus 2G Electric thrust actuator Electric thrust actuator ARI-PREMIO -Plus 2G Electric thrust actuator ARI-PREMIO -Plus 2G 2,2-5 kn Page 2 Electric thrust actuator ARI-PREMIO -Plus 2G 12-25

More information

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS

MICROFUSION FEATURES OPTIONS CERTIFICATIONS THREE PHASE SCR POWER CONTROLLERS MICROFUSION THREE PHASE SCR POWER CONTROLLERS FEATURES Auto-Ranging Input Voltage 24-600 VAC, 45-65 Hz AC Output 8, 16, 32, 50, 80 Amps (@ 50 C 6000 ft) Control Features Microprocessor-based controller

More information

EFC 3600 Frequency converter for higher energy efficiency and improved process control

EFC 3600 Frequency converter for higher energy efficiency and improved process control EFC 3600 Frequency converter for higher energy eiciency and improved process control 2 Valuable energy used responsibly Rising energy costs and increasing demands on the environmentally sound products

More information

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Radiocontrol F. Floor Heating Controller Radio control system for floor heating Radiocontrol F Floor Heating Controller Radio control system for floor heating IMI HEIMEIER / Floor Heating Control / Radiocontrol F Radiocontrol F The Radiocontrol F radio control system for controlling

More information

INTER PLANT STANDARD STEEL INDUSTRY VARIABLE VOLTAGE VARIABLE FREQUENCY SYSTEM (V.V.V.F.) V/F, VECTOR CONTROL / TORQUE CONTROL

INTER PLANT STANDARD STEEL INDUSTRY VARIABLE VOLTAGE VARIABLE FREQUENCY SYSTEM (V.V.V.F.) V/F, VECTOR CONTROL / TORQUE CONTROL INTER PLANT STANDARD STEEL INDUSTRY VARIABLE VOLTAGE VARIABLE FREQUENCY SYSTEM (V.V.V.F.) V/F, VECTOR CONTROL / TORQUE CONTROL IPSS: 1-10-035-06 IPSS Corresponding IS does not exist 0. FOREWORD 0.1 This

More information

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement

ULTRASONlC FlOWMETER SAMPLE BOOK. TYPE:LRF-3300S Concentrating on Flow Measurement ULTRASONlC FlOWMETER SAMPLE BOOK TYPE:LRF-3300S Concentrating on Flow Measurement Introduction LRF-3300S is a wall-mount, clamp- on type ultrasonic flowmeter which use the transfer time technology. Clamp

More information

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps. VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload

More information

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS

nd30pnet - METER Of POwER NETwORk PARAMETERS with profinet EXAMPlE Of APPlICATION MEASUREMENT ANd VISUAlIZATION Of POwER NETwORk PARAMETERS nd30pnet tri Measurement of 54 power network parameters, including current and voltage harmonics up to 51st, in 1-phase 2-wire or 3-phase 3 or 4-wire balanced and unbalanced systems. graphical color display:

More information

Miniature resistance thermometer Model TR33, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted Electrical temperature measurement Miniature resistance thermometer Model TR33, thread-mounted WIKA data sheet TE 60.33 Applications Machine building, plant and vessel construction Propulsion technology,

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature Data Sheet 20272 Page /7 JUMO ecotrans Lf 0 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature Type 20272 Housing for DIN rail mounting (5 x 7.5 mm to DIN EN

More information

Absolute encoders - SSI

Absolute encoders - SSI with through hollow shaft Features Encoder multiturn / SSI Optical sensing method Resolution: singleturn 14 bit, multiturn 12 bit Compact design Cost-efficient mounting High reliability by self-diagnostics

More information

Main Features. Highlights

Main Features. Highlights Highlights For portable use or continuos system; Multi-position measuring system using wireless communication from MASTER to SLAVE units; N.4 analog inputs, n.1 digital inputs; Inputs extension using MASTER/SLAVE

More information

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web:  - ADJUSTABLE SPEED DRIVES HX7 Series 18 Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion

More information

Design Specifications Operator Keypad Environmental and Operating Conditions

Design Specifications Operator Keypad Environmental and Operating Conditions Series 15J Mini Inverters Big inverter features do come in small packages! Take a look at Baldor s Series 15J Inverter control. Designed to save cabinet space without giving up the features available on

More information

em4 local - Robust Specific characteristics Part number

em4 local - Robust Specific characteristics Part number em4 em4 local em4 local Very compact and easy to program nanoplc Save time in designing your application using the most intuitive graphical function block language of the market Measure accurately your

More information

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES

PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES PURE SINE WAVE INVERTERS WITH INTEGRATED BATTERY CHARGER FOR VEHICLES ECE R10-05 PURE SINE WAVE HIGH FREQUENCY INVERTERS FOR VEHICLES Kert is always ready to help you! If you need: Advices for the purchase

More information

Improve asset protection and utilization

Improve asset protection and utilization QUALITROL 509 ITM Intelligent transformer monitor Improve asset protection and utilization Immediately know your transformer health with TransLife Optimize loading and equipment life Simplify root cause

More information

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems

isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor

More information

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW Characteristics soft starter for asynchronous motor - ATS48-65 A - 208..690 V - 15..55 KW Main Range of product Altistart 48 Product or component type Product destination Product specific application Device

More information

Electronic fan speed regulators

Electronic fan speed regulators Electronic fan speed regulators Purpose The fan speed controller maintains the condensing pressure for fan-type condensers or fluid outlet temperatures for dry coolers, within prefixed values, for any

More information

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA Taking into account that power transformer is the major item of equipment in power systems, its correct operation is vital to system operation. It is well known that transformer failures are sometimes

More information

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR 6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR Power supply It is based upon the latest switch mode power supply technology, offering size reduction (smallest 6 kw available on the market,

More information

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION EN K09LV LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION General Description The K09LV instrument is a three points galvanic insulator, with input on high sensitivity voltage, and active output.

More information

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I Memory 256 MB Alarm management Residual current measurement Homepage Ethernet-Modbus gateway BACnet (optional) UMG 96 RM-E Power analyser with Ethernet and RCM Communication Modbus (RTU, TCP, Gateway)

More information

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature Temperature control: Feel good at any time of year Room thermostats Heating time switches Excellent products

More information

Inverter MICROMASTER 410

Inverter MICROMASTER 410 Inverter MICROMASTER 40 /2 Description /4 Circuit diagrams /6 Technical data /7 Selection and ordering data /8 Options /0 Dimension drawings Siemens DA 5.2 2005/2006 / MICROMASTER 40 Description Inverter

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

Baro Transmitter PTB x1.073

Baro Transmitter PTB x1.073 THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021570/04/08 Baro Transmitter PTB 110 3.1158.x1.073 ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083

More information

LST100 Ultrasonic level transmitter for upstream oil and gas

LST100 Ultrasonic level transmitter for upstream oil and gas Data sheet DS/LST100-EN LST100 Ultrasonic level transmitter for upstream oil and gas Accurately track and measure the most expensive consumable on your site chemicals. Measurement made easy Features Keep

More information

Electronic Thermostat TE-1 Version according to EN

Electronic Thermostat TE-1 Version according to EN JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO

More information

Process displays For standard signals, temperature, resistance measurement

Process displays For standard signals, temperature, resistance measurement Features Inputs: Voltage ±10 V, ±200 V / Current ±20 ma / thermocouples J,K,T,N,Pt100,Pt1000 / resistance measurement / potentiometer Display range can be linearised Two limits output Min, Max functions

More information

R-Log Radio data logger

R-Log Radio data logger > data loggers R-Log Radio data logger Highlights For portable use or continuos system; Multi-position measuring system using wireless communication from MASTER to SLAVE units; N.4 analog inputs, n.1 digital

More information

Digital Indicator DS 96/48 PK

Digital Indicator DS 96/48 PK Data Sheet 10/33-2.1-EN Digital Indicator DS 9/48 P Digital Indicator DS 9/48 PK Inputs Direct current, direct voltage Thermocouple Resistance thermometer Programmable via front keys or PC software Limit

More information

Level Measurement silometer FMX 570

Level Measurement silometer FMX 570 Technical Information TI 01F/00/en Level Measurement silometer FMX 570 Measurement of liquids and bulk solids Suitable for explosion hazardous areas For use with capacitance and hydrostatic probes The

More information

s Climatix extension module 26 I/Os POL985.00/XXX

s Climatix extension module 26 I/Os POL985.00/XXX s 3 921 Climatix TM Climatix extension module 26 I/Os POL985.00/XXX The POL985.00/XXX extension module extends the number of I/Os of Climatix 600 controllers. It is a product of the Climatix range. The

More information

WIRING DIAGRAMS FOR SMART MODELS

WIRING DIAGRAMS FOR SMART MODELS SMART SERIES CODING SYSTEM FOR AV ACTUATOR WIRING DIAGRAMS There are 3 elements to the wiring codes used in AVA electric actuators: CONTROL WIRING CODE CONTROL WIRING TYPE 1 3 Wire system, single pole

More information

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5 New Information Electric Current! Danger to Life! Only skilled or instructed persons may carry out the following operations. Variable Speed Micro Drives for Machinery Applications () VSxxx0_, VSxxx2x4_,

More information

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track) The transmitter FUS080 is

More information