Table 6.1 Fault Code List Code indication (Note 3)
|
|
- Hilda Clark
- 6 years ago
- Views:
Transcription
1 62 Table 6.1 Fault List UA801 UA802 UA803 UA804 UA805 UA806 UA807 UA808 UA810 UA812 UA813 UA814 UA815 UA817 UA821 AC VOLTAGE OUT OF RANGE AC FREQUENCY OUT OF RANGE AC PHASE ROTATION ERROR OPE. OVER OVER OVER OVER OVER VOLTAGE OUT OF RANGE PHASE ROTATION ERROR FREQUENCY OUT OF RANGE EMERGENCY STOP ACTIVATED Input line voltage is out of the specific range. Input line frequency is out of the specified range. Input line power conductors are not wired in a proper phase sequence. The converter interlock is active. exceeded 105% of the rated exceeded 110% of the rated exceeded 125% of the rated exceeded 150% of the rated Short time overcurrent has exceeded 150% of the rated current Bypass line voltage is out of the specific range. Bypass line power conductors are not wired in a proper phase sequence. Bypass line frequency is out of the specific range. Transfer to bypass is not available due to bypass ity. The emergency stop was activated by the EPO switch or an external contact. The UPS cannot transfer to the bypass because the inverter output is not synchronized to the bypass. POWER SOURCE POWER SOURCE POWER SOURCE AC input AC input AC input Bypass Input Abnormal Bypass Input Abnormal Bypass Input Abnormal
2 63 UA822 UA824 UA827 UA831 UA833 UA834 UA835 UA860 UA861 UA870 UA890 UF001 UF002 UF003 UF011 UF052 UF056 UF059 UF102 CB2 OPEN 52C OPE. EMERGENCY SWITCH ON 52L OPEN DEPLETED/AC OUT STOPPED REMOTE BUTTON LOCAL BUTTON BALANCER OVER EXTERNAL ALARM CIRCUIT CB1 CB1 CIRCUIT DC OVERVOLTAGE The UPS cannot transfer to the bypass because of backup generator operation. The battery circuit breaker (CB2) is open. The interlock for the inverter output contactor (52C) is active. Emergency bypass switch has been turned on. The load circuit breaker (52L) is turned off. The battery voltage has reached the depleted level. The UPS could not transfer to the bypass because the bypass source has an ity. Remote start or stop signal is being received continuously for a considerable time. Local start or stop signal is being received continuously for a considerable time. The UPS detected a neutral point voltage unbalance. relay turned on. of the reference error signal. Detection of converter Precharging circuit is not working properly. discrepancy between reference signal and actual state of contactor CB1. discrepancy between reference signal and actual state of contactor CB1. Detection of converter of the reference error signal. DC voltage surpasses the overvoltage level. TURN ON CB2 Endof Discharge
3 64 UF103 UF108 UF109 UF110 UF111 UF112 UF119 UF128 UF151 UF152 UF154 UF156 UF157 UF158 UF159 UF160 UF161 UF162 DC UNDERVOLTAGE CHOPPER DC UNBALANCED ZERO PHASE DC CIRCUIT DC GROUND FAULT CONTROL POWER SUPPLY DC VOLTAGE DC VOLTAGE CB2 CHG.STOPPED ( OVERTEMP.) OVERTEMPERA TURE LIQUID LOW DC GROUND FAULT CHG.STOPPED (DC VOLT. ) DC voltage dropped below the undervoltage level. Detection of DC unbalance of the neutral point voltage. Detection of converter zerosequence Battery current unbalance. Sudden change of the DC voltage level. Detection of DC ground fault. Power supply voltage to IGBT driver PCB is below the specified level. 24 hours after input power restoration, batteries do not reach float voltage level. Unable to equalize the voltage of various batteries after 24 hours. During UVT, status signal from CB2 is ON. UF157 failure persisted for over 2 hours. Detection of overtemperature at the batteries. Low level of battery electrolyte solution. Detection of DC ground fault. Abnormal behavior of DC current sensor. UF151 failure is running for over 24 hours. detection based on battery selfcheck. s ound Battery Battery Battery
4 65 UF163 UF170 UF171 UF201 UF202 UF203 UF204 UF206 UF207 UF208 UF209 UF210 UF211 UF213 UF214 UF217 UF230 VOLTAGE VDB SENSOR OVERVOLTAGE UNDERVOLTAGE OUTPUT CIRCUIT ZERO PHASE 52C 52C 52C OVERTEMPERAT URE COOLING FAN OVERVOLTAGE ZERO PHASE Battery voltage is ity. of the difference between controlonly and protectiononly battery voltage. Battery current unbalance. Detection of output overvoltage. Output voltage dropped. Detection of inverter of the reference error signal (current reference and actual current). Discrepancy between output voltage and external voltage (bypass, common ac bus) Inverter zerosequence Cross current is ity. Error to close the contactor 52C. Error to open the contactor 52C. No answer from contactor 52C during inverter operation. Heatsink s temperature exceeds thermal settings. Thermal relay activated protection. Detection of inverter output phase overvoltage. Detection of zerosequence
5 66 UF253 UF256 UF257 UF258 UF259 UF301 UF302 UF303 UF305 UF306 UF309 UF310 UF320 UF323 UF352 UF363 UF371 UF372 OUTPUT VOLTAGE 52C ANOTHER UPS VOLTAGE CONTROL POWER SUPPLY CONTROL POWER SUPPLY Discrepancy between output voltage and inverter voltage, or between output voltage and bypass voltage. Output voltage is out of the specified range. Contactor 52C failed to open during load transfer from inverter to bypass. Load transfer due to overload for over 4 times within 5 minutes. No detection of another UPS voltage signal. AD reference has an value. Detection of an external interruption during the software execution. Timer does not reset in the specified period (WDT settings) Detection of an clock speed in the DSP or FPGA. Control power supply voltage is below the specified level. Inverter voltage is out of the specified range. Backup control power supplies exhibit condition. Cable disconnection in the parallel interface board during load supply. communication error during parallel operation. Backup control power supplies exhibit condition. Synchronization status signal is being received for a considerable time. communication error during parallel operation. Unable to synchronize the inverter output and the bypass voltage.
6 67 UF374 UF375 UF376 UF377 UF378 UF379 UF401 UF402 UF420 UF451 UF452 52S 52S 52L OPERATION ERROR 52S CB3 Cable disconnection in the parallel interface board. Unable to achieve synchronization for parallel operation. No control response from another UPS although its detection is possible. detection signal is being received continuously for a considerable time. No answer for sending synchronizing signal. Abnormal clock speed of the parallel control board processor. Error to close the contactor 52S. Error to open the contactor 52S. Load circuit breaker 52L opened during inverter operation. Contactor 52S failed during load transfer from inverter to bypass. Contactor CB3 is not working properly. 52L s ound 1) "" is defined as a major failure. Load transferred from the inverter circuit to the static bypass line; 2) "" is defined as a minor failure. UPS continues to operate normally, but cause of alarm must be identified; Indicates one of two possible LED illumination patterns continuously on (lit on) or intermittent (flicker). means: UA+++ UF+++ U%0++ Rectifier circuit failure U%1++ DC circuit failure U%2++ Inverter circuit failure U%3++ Control circuit failure U%4++ Bypass system failure
7 68 U%8++ U%+00 U%+49 failure U%+50 U%+99 failure *) + denotes any numeral from 0 to 9 *) % denotes either A or F
GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL
1.1 SUMMARY Liebert NX UPS GUIDE SPECIFICATIONS 40-80kVA, 80-120kVA and 160-200kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL This specification defines the electrical and mechanical
More informationModbus Register Map: InfraStruXure Symmetra 3-Phase Absolute Starting Register Number, (Decimal)
Modbus Map: InfraStruXure Symmetra 3-Phase 990-3249 // Status Word 0 40000 0 8 Reserved R = UPS ready to provide power to the load upon return of normal line voltage or upon user command = State == Enable
More informationSECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM
SECTION 263353 - THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM PART 1 GENERAL 1.1 SUMMARY A. This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty three-phase,
More informationMITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS
MITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS Copyright Mitsubishi Electric Power Products TABLE OF CONTENTS 1. SCOPE... 1 1.1 The System... 1 2. SYSTEM DESCRIPTION... 1 2.1 Components... 1 2.2 Modes
More informationTOSHIBA International Corp
TOSHIBA International Corp GUIDE SPECIFICATIONS THREE PHASE UNINTERRUPTIBLE POWER SYSTEM TOSHIBA 4200FA 30 kva CT Internal Battery UPS GUIDE SPECIFICATIONS 1 (30 kva CT) 1.0 SCOPE 1.1 System This specification
More informationNumbering System for Protective Devices, Control and Indication Devices for Power Systems
Appendix C Numbering System for Protective Devices, Control and Indication Devices for Power Systems C.1 APPLICATION OF PROTECTIVE RELAYS, CONTROL AND ALARM DEVICES FOR POWER SYSTEM CIRCUITS The requirements
More informationUNINTERRUPTIBLE POWER SUPPLY SINGLE MODULE SYSTEM SPECIFICATIONS MODEL 9800AE
UNINTERRUPTIBLE POWER SUPPLY MODEL 9800AE SINGLE MODULE SYSTEM SPECIFICATIONS In no event shall MEPPI be liable for the accuracy, completeness or usefulness of the following specifications or for any modification(s)
More informationUNINTERRUPTIBLE POWER SUPPLY MODEL 9900B SPECIFICATIONS
UNINTERRUPTIBLE POWER SUPPLY MODEL 9900B SPECIFICATIONS TABLE OF CONTENTS PART 1 GENERAL... 2 1.1 SUMMARY... 2 1.2 STANDARD... 2 1.3 SYSTEM DESCRIPTION... 2 1.3.1 Components... 2 1.3.2 Mode of Operation...
More informationIn the event of a failure, the inverter switches off and a fault code appears on the display.
Issue 03/05 Faults and Alarms 5 Faults and Alarms 5.1 Fault messages In the event of a failure, the inverter switches off and a fault code appears on the display. NOTE To reset the fault code, one of three
More informationW o r l d C l a s s P o w e r S o l u t i o n s Internal power supply UPS mains operation UPS battery operation Bypass operation Parallel operation Manual bypass Overload Inverter failure Mains failure
More informationProtecting Large Machines for Arcing Faults
Protecting Large Machines for Arcing Faults March 2, 2010 INTRODUCTION Arcing faults occur due to dirty insulators or broken strands in the stator windings. Such faults if undetected can lead to overheating
More informationAppendix C, Paper 3 C-17
Appendix C, Paper 3 C-17 C-18 C-19 C-20 C-21 C-22 C-23 C-24 C-25 C-26 Appendix D USER S MANUAL SEMITEACH Based Converter System for Electrical Machines Jawwad Zafar Copyright 2010 by the Université Libre
More informationUNINTERRUPTIBLE POWER SUPPLY MODEL 9900AEGIS SPECIFICATIONS
UNINTERRUPTIBLE POWER SUPPLY MODEL 9900AEGIS SPECIFICATIONS TABLE OF CONTENTS PART 1 GENERAL... 2 1.1 SUMMARY... 2 1.2 STANDARD... 2 1.3 SYSTEM DESCRIPTION... 2 1.3.1 Components... 2 1.3.2 Mode of Operation...
More informationGenerator Protection GENERATOR CONTROL AND PROTECTION
Generator Protection Generator Protection Introduction Device Numbers Symmetrical Components Fault Current Behavior Generator Grounding Stator Phase Fault (87G) Field Ground Fault (64F) Stator Ground Fault
More informationPower systems Protection course
Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering 1 Part 5 Relays 2 3 Relay Is a device which receive a signal from the power system thought CT and
More informationError codes for REFUsol 012K/016K/020K/024K - UL
0 Error management 0x000000 Error was possibly acknowledged although this was not allowed. Else, the error cause cannot be reconstructed. Restart 131074 DC voltage 2 DC link voltage too high: the DC link
More informationNX Series Inverters. HVAC Pocket Programming Guide
NX Series Inverters HVAC Pocket Programming Guide HVAC Pocket Programming Guide HVAC Pocket Programming Guide / Contents This guide provides a single reference document for the user of NXL HVAC (product
More informationInfraStruXure Manager v4.x Addendum: Building Management System Integration
InfraStruXure Manager v4.x Addendum: Building Management System Integration Introduction This addendum explains the integration of the APC InfraStruXure Manager Appliance with a Building Management System
More informationSTATIC UNINTERRUPTIBLE POWER SYSTEM Revised 4/30/ Electrical Systems
SECTION 26 33 53 - STATIC UNINTERRUPTIBLE POWER SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty three-phase,
More informationQuick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB
DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks
More informationINSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12
INSTRUCTION MANUAL Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS Power Factor Controller A12 1. CONTENTS 1. CONTENTS 1 2. FEATURES 2 3. INSTALLATION, CONNECTION AND APPLYING POWER 2 4.
More informationMicrogrid Protection
Panel: Microgrid Research and Field Testing IEEE PES General Meeting, 4-8 June 7, Tampa, FL Microgrid Protection H. Nikkhajoei, Member, IEEE, R. H. Lasseter, Fellow, Abstract In general, a microgrid can
More informationPARAMETER LIST PARAMETER LIST
PRMETER LIST PRMETER LIST dvanced Genset Controller, GC 200 larm list Parameter list Document no.: 489340605L SW version 4.2.x or later GC 200 parameter list 489340605 UK Contents: General information...
More informationGutor PxW AC UPS Designed for North American Market
Gutor PxW AC UPS Designed for North American Market PEW 5 200 kva single phase PDW 10 220 kva three phase Higher ratings upon request schneider-electric.com 2 schneider-electric.com schneider-electric.com
More informationGeneral-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)
General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) B Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment
More informationGeneral-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)
General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) B Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment
More informationPower Supply Unit (550W)
Contents Power Supply Unit (550W) Chapter 3.1 GENERAL DESCRIPTION...3.1-1 APPLIED VOLTAGE...3.1-2 INPUT CURRENT...3.1-2 DC OUTPUT...3.1-3 VOLTAGE DROPOUT...3.1-4 OUTPUT ISOLATION...3.1-4 OVERLOAD/UNDERLOAD
More informationCOOPERATIVE PATENT CLASSIFICATION
CPC H H02 COOPERATIVE PATENT CLASSIFICATION ELECTRICITY (NOTE omitted) GENERATION; CONVERSION OR DISTRIBUTION OF ELECTRIC POWER EMERGENCY PROTECTIVE CIRCUIT ARRANGEMENTS (indicating or signalling undesired
More informationPlease note and refer to warning marks which you will find in the unit.
Table of contents 1.0 Preface ---------------------------------------------------------------------------------------- 1-1 1-1 Introduction ----------------------------------------------------------------------------
More informationGeneral-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)
General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) D Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment
More informationGeneral-Purpose AC Servo. MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)
General-Purpose AC Servo MELSERVO-JE Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) F Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment
More informationNIPSCO Energy Symposium
Backup Power Automatic Transfer NIPSCO Energy Symposium symposium Backup Power Applications/Considerations Backup Power Types Automatic Transfer Switch Basics Presenters McGill Power - Jeremy Irmeger Eaton
More informationCHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3
CHAPTER MAINTENANCE AND 6 TROUBLESHOOTING In This Chapter... Maintenance and Inspection.................6 2 Monthly Inspection:..................................6 2 Annual Inspection....................................6
More informationTroubleshooting 12. This section explains the items to check when problems occur, and troubleshooting by the use of error displays or operation state.
Troubleshooting 12 This section explains the items to check when problems occur, and troubleshooting by the use of error displays or operation state. 12-1 Actions for Problems..........................................
More informationFuseless Capacitor Bank Protection
Fuseless Bank Protection Minnesota Power Systems Conference St. Paul, MN. November 2, 1999 by: Tom Ernst, Minnesota Power Other Papers of Interest Presented at Western Protective Relay Conference, Oct.
More informationGeneral-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)
General-Purpose AC Servo MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) K Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment
More informationQuick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB. For Immediate Delivery call KMParts.com at (866)
DF5-... Frequency Inverters 1 st published 22, edition 02/02 Moeller GmbH, 53105 Bonn Author: Holger Friedrich Editor: Michael Kämper Translator: Dominik Kreuzer All brand and product names are trademarks
More informationGESS Industrial UPS System. Overview
GESS Industrial UPS System Overview Industrial UPS System Rectifier with Isolation Transformer Inverter with Isolation Transformer By-pass line Voltage Stabilizer with Isolation Transformer > Individual
More informationGrid Emulator (GE) Installation and operation manual. Caltest Instruments GmbH Kohlmattstrasse 7 D KAPPELRODECK
Grid Emulator (GE) Installation and operation manual Caltest Instruments GmbH Kohlmattstrasse 7 D-77876 KAPPELRODECK info@caltest.de Tel: +49(0)7842-99722-00 Fax: +49(0)7842-99722-29 www.caltest.de INDEX
More informationInstallation and start up instructions. Detection of vector shift. Detection of over- and underfrequency. Generator disconnection on mains failure
Installation and start up instructions G59 Relay Package uni-line 4189340236C (UK) Detection of df/dt (rate of change of frequency R.O.C.O.F.) Detection of vector shift Detection of over- and underfrequency
More informationCapacitor protection relay
Capacitor Protection Relay FEATURES Capacitor unbalance protection Line current unbalance protection Overvoltage protection Overheating protection Ground fault protection Overcurrent protection Undercurrent
More informationBrief description of KR 15 controllers
Brief description of KR 15 controllers E N E R G Y R E C O V E R Y Page 2 Page 4 Page 5 Page 6 Page 9 1. Function of the controller 2. Terminal connections 3. Technical data 4. Initial operation 5. Manual
More informationContents. 1 Introduction Assessment criteria Assessment Recommendations References... 8
Note: This is a translation of the RSK recommendation entitled Ein- oder zweiphasiger Ausfall des Haupt-, Reserve- oder Notstromnetzanschlusses. In case of discrepancies between the English translation
More information1. Institute of Electrical and Electronic Engineers (IEEE) a. Standard , IEEE Guide for Harmonic Content and Control.
Section 16680 VARIABLE SPEED DRIVE SYSTEMS OR AFD Part I - GENERAL I.01 Description A. This specification is to cover a complete adjustable frequency motor drive consisting of a pulse width modulated (PWM)
More informationIndustrial Electrician Level 3
Industrial Electrician Level 3 Industrial Electrician Unit: C1 Industrial Electrical Code I Level: Three Duration: 77 hours Theory: Practical: 77 hours 0 hours Overview: This unit is designed to provide
More informationTechnical Data Sheets
GE Consumer & Industrial Power Protection Technical Data Sheets Digital Energy Uninterruptible Power Supply SG Series 80 100 120 kva 400 Vac CE Series 0 Date of issue: 01.11.2007 SGSE_080_UPS_GE_01a SGSE_100-120_UPS_GE_01a
More informationUNINTERRUPTIBLE POWER SUPPLY SPECIFICATIONS MODEL 1100B SERIES
UNINTERRUPTIBLE POWER SUPPLY MODEL 1100B SERIES SPECIFICATIONS In no event shall MEPPI be liable for the accuracy, completeness or usefulness of the following specifications or for any modification(s)
More informationVFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.
VFD - D700 Series Specifications The latest low-cost variable speed control solution for centrifugal pumps. Built-in PID Control to maintain pressure, flow, measured value, and much more 125% overload
More informationNGS INVERTER REPLACEMENT SCOPE OF WORK & SPECIFICATIONS
NGS INVERTER REPLACEMENT SCOPE OF WORK & SPECIFICATIONS TABLE OF CONTENTS Section 1.0 General... 3 1.1 Work Included... 3 1.2 Related Work... 3 1.3 System Description... 3 1.4 System Operation... 4 1.5
More informationChapter 8 Troubleshooting
Chapter -1 Error Processing... -1 Preliminary Checks When a Problem Occurs...-1 Precautions When...-2 Replacing the Servomotor and Servo Drive...-2-2 Alarm Table... -3-3... -7 Error Diagnosis Using the
More informationVariable Frequency Drive / Inverter (0.4 ~ 280kW)
Variable Frequency Drive / Inverter (0.4 ~ 280kW) & Standard Features Configuration Comparison Comparison Table Enclosure IP00 IP20 NEMA 1 Rating Single phase 0.4 2.2kW 0.4 1.5kW Three phase 0.4 4kW Constant
More informationP. O. BOX 269 HIGHLAND, ILLINOIS, U.S.A PHONE FAX
SSE-N NEGATIVE FIELD FORCING SHUNT STATIC EXCITER/REGULATOR SYSTEM Control Chassis 6 SCR Power Chassis APPLICATION The SSE-N Negative Field Forcing Exciter/Regulator is used for both new and old installations
More informationSECTION AUTOMATIC TRANSFER SWITCH
SECTION 26 36 23 PART 1 - GENERAL 1.1 THE REQUIREMENT A. Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, withstand and close-on ratings as shown on the plans.
More informationThe NMIH-0050 H-Bridge
The NMIH-0050 H-Bridge Features: 5 A continuous, 6 A peak current Supply voltages from 5.3V up to 40V Terminal block for power / motor Onboard LEDs for motor operation/direction Onboard LED for motor supply
More informationOperating Instructions
4XH35QB151210 Small General Frequency Converter Operating Instructions 220V 0.75KW 5.5KW 400V 0.75KW 15KW Please read the instruction carefully and understand the contents so that it can be installed and
More informationSECTION [ ] [16611] SOLID STATE UNINTERRUPTIBLE POWER SUPPLY
APC by Schneider Electric MGE GALAXY PW Data Center Grade Three Phase Uninterruptible Power Supply Parallel Module - Guide Specifications 150-225 kva UPS THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE
More informationFeatures: Phase A Phase B Phase C -DC_A -DC_B -DC_C
Three Phase Inverter Power Stage Description: The SixPac TM from Applied Power Systems is a configurable IGBT based power stage that is configured as a three-phase bridge inverter for motor control, power
More informationTroubleshooting Alarm Displays Warning Displays
10 10.1 Alarm Displays............................................10-2 10.1.1 List of Alarms...................................................... 10-2 10.1.2 of Alarms............................................
More information2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.
1.0 Scope This document describes the specification for Toshiba 1000 Series On-Line Uninterruptible Power System (UPS). The UPS will supply a computer grade AC output sine wave which is unaffected by the
More informationProtective Relaying for DER
Protective Relaying for DER Rogerio Scharlach Schweitzer Engineering Laboratories, Inc. Basking Ridge, NJ Overview IEEE 1547 general requirements to be met at point of common coupling (PCC) Distributed
More informationETSI TS V1.3.1 ( )
TS 102 121 V1.3.1 (2014-07) TECHNICAL SPECIFICATION Environmental Engineering (EE); Power distribution to telecommunications and datacom (ICT) 2 TS 102 121 V1.3.1 (2014-07) Reference RTS/EE-02041 Keywords
More informationCompany Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D
Document type Page Verksamhetsstyrande 1 (11) Company Replaces previous document Document ID Issue E.ON Elnät Sverige AB Ny engelsk utgåva D17-0008990 1.0 Organisation Valid from Valid until Regionnätsaffärer
More informationSystem Protection and Control Subcommittee
Power Plant and Transmission System Protection Coordination Reverse Power (32), Negative Sequence Current (46), Inadvertent Energizing (50/27), Stator Ground Fault (59GN/27TH), Generator Differential (87G),
More informationDesign, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter
1 Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter Nee, Staffan Norrga, Remus Teodorescu ISBN-10: 1118851560
More informationDLVP A OPERATOR S MANUAL
DLVP-50-300-3000A OPERATOR S MANUAL DYNALOAD DIVISION 36 NEWBURGH RD. HACKETTSTOWN, NJ 07840 PHONE (908) 850-5088 FAX (908) 908-0679 TABLE OF CONTENTS INTRODUCTION...3 SPECIFICATIONS...5 MODE SELECTOR
More informationZT-30 ZeroTEM TRANSMITTER MANUAL
ZT-30 ZeroTEM TRANSMITTER MANUAL 06 September, 2000 Zonge Engineering and Research Organization, Inc. 3322 East Fort Lowell Road, Tucson, AZ 85716 USA Tel:(520)327-5501 Fax:(520)325-1588 Email:zonge@zonge.com
More informationInstallation/operation instructions. Insulation monitor type SIM-Q/SIM-Q LF D (UK) Measuring range 1...0Mohm or 10...
Installation/operation instructions Insulation monitor type SIM-Q/SIM-Q LF Monitoring of insulation resistance on an AC network Working voltage up to 690V AC, withstands up to 1000V DC Measuring range
More informationPOWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS
POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A
More informationA NEW DIRECTIONAL OVER CURRENT RELAYING SCHEME FOR DISTRIBUTION FEEDERS IN THE PRESENCE OF DG
A NEW DIRECTIONAL OVER CURRENT RELAYING SCHEME FOR DISTRIBUTION FEEDERS IN THE PRESENCE OF DG CHAPTER 3 3.1 INTRODUCTION In plain radial feeders, the non-directional relays are used as they operate when
More informationNXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives
NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives Page 2 (68) Index Honeywell HVAC Application (Software [ALFIQ105] Ver.2.09) INDEX 1. INTRODUCTION... 3 2. CONTROL I/O... 3. HVAC APPLICATION
More informationTECHNICAL DATA SHEET B9600FXS kva
GENERAL INFORMATION TECHNICAL DATA SHEET B9600FXS 400-500-600-800 kva UPS Type ON LINE - Double Conversion Nominal output power (Cos 0.9) kva 400 500 600 800 Nominal output power (Cos 1.0) kw 360 450 540
More informationMicroprocessor Control Board Set Up Procedures (OR PLC)
Microprocessor Control Board Set Up Procedures (OR-00 PLC) SWITCHES/PUSHBUTTONS Push Buttons at display SW Enter button SW Back button SW Down SW UP Back light on/off switch Rotary switches on main board
More informationTable K. Input/Output Ratings & External Wiring Requirements for the Powerware /80 Rating 50/60 Hz. kva kw VOLTS VOLTS / /220
Table K. Input/ Ratings & External Wiring Requirements for the 9390-/ Units Rating 50/0 Hz Basic Unit Rating at 0.9 lagging pf load Input and Bypass Input Rectifier (0.98 min. pf) plus Recharge Current
More informationElectrical Motor Controls Chapter 5 (4 th Edition) Chapter 5 (5 th Edition)
Electrical Motor Controls Chapter 5 (4 th Edition) Chapter 5 (5 th Edition) 1. How many loads should be placed in any one circuit line between L 1 and L 2? 2. If more than one load is controlled by the
More informationDP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation
DP&L s Technical Requirements for Interconnection and Parallel Operation of Distributed Generation Technical Requirements for Interconnection and Parallel Operation of Distributed Generation Single Phase
More informationMODBUS Protocol for CS101 network card family
MODBUS Protocol for CS1 network card family 1 MODBUS tables Please note that not all the data are available for all UPSs. The addresses are in PLC mode (base 1). Type: U means without arithmetic sign,
More informationADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W
ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000
More informationTechnical catalogue. Emax Low voltage air circuit-breakers. Hotline:
Technical catalogue Emax Low voltage air circuit-breakers www.alobitanbd.com Hotline: 01711548558 PAGE : 02 The new Emax have received innumerable international certifications and approval by the major
More informationNERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell
Power Plant and Transmission System Protection Coordination GSU Phase Overcurrent (51T), GSU Ground Overcurrent (51TG), and Breaker Failure (50BF) Protection NERC Protection Coordination Webinar Series
More informationREF 610 Feeder Protection Relay. Technical Reference Manual
REF 610 1MRS 755310 Issued: 05.10.2004 Version: A/05.10.2004 REF 610 Contents 1. Introduction...6 1.1. About this manual...6 1.2. The use of the relay...6 1.3. Features...6 1.4. Guarantee...8 2. Safety
More informationGeneral-Purpose AC Servo. MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING)
General-Purpose AC Servo MELSERVO-J4 Servo amplifier INSTRUCTION MANUAL (TROUBLE SHOOTING) N Safety Instructions Please read the instructions carefully before using the equipment. To use the equipment
More informationIAP200T120 SixPac 200A / 1200V 3-Phase Bridge IGBT Inverter
Configurable Power FEATURES INCLUDE Multi-Function Power Assembly Compact Size 9 H X 17.60 W X 11.00 D DC Bus Voltages to 850VDC Snubber-less operation to 650VDC Switching frequencies to over 20kHz Protective
More informationNo. SSIEC-SEW SHINSUNG. Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A
SHINSUNG Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A Enhanced Self Healing System General SILO is 3 phase, solid insulated load break switch (LBS) and vacuum interruption
More informationSUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches
SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand
More informationProtection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin
Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc. 770 565-1556 John@L-3.com 1 Protection Fundamentals By John Levine 2 Introductions Tools Outline Enervista Launchpad
More informationFixed Series Compensation
Fixed Series Compensation High-reliable turnkey services for fixed series compensation NR Electric Corporation The Fixed Series Compensation (FSC) solution is composed of NR's PCS-9570 FSC control and
More informationCapstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:
Phone: (818) 734-5300 Fax: (818) 734-5320 Web: www.capstoneturbine.com Technical Reference Capstone MicroTurbine Electrical Installation 410009 Rev F (October 2013) Page 1 of 31 Capstone Turbine Corporation
More informationOperation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!
Operation Manual Congratulations on purchasing your high quality AIMS Power pure sine inverter! It is very important that you read and understand this instruction manual completely prior to use. Contained
More informationPOWER-GATE Non-Programmable OR ING (Generation 4.0) Application Sheet
1 POWER-GATE Non-Programmable OR ING (Generation 4.0) Application Sheet CONDUCTOR SIZING IMPORTANCE The MOSFET arrays used in the generation 4.0 POWER-GATE non-programmable OR ing (hereafter referred to
More informationRELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD
RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES Power Management Instruments FROM PMI & OES GROUP COMPANIES SUD Today, as technology evolves, Electrical, Electronic and Electromechanical devices are
More informationPHOENIX CONTACT - 09/2009
Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits
More informationReview: The Ameritron ALS Watt HF Power Amplifier Phil Salas AD5X
Review: The Ameritron ALS-1300 1200-Watt HF Power Amplifier Phil Salas AD5X Introduction The new Ameritron ALS-1300 is a 160-10 meter 1200 watt output all solid-state amplifier with manual band switching
More informationNAME OF (VENDOR/MANUFACTURER) Clause No. Clause Description Comments, if any Remarks, if any
BSNL seeks comments on Draft GR for UPS from UPS/Invertors vendors BSNL INVITES COMMENTS FROM UPS / INVERTOR VENDORS ON DRAFT GR FOR UPS PREPARED BY BSNL. COMMENTS MAY BE GIVEN TO BSNL CORPORATE OFFICE,
More informationSPECIFICATION. Online UPS 3000VA
Page 1 / 7 DESCRIPTION Pure sine-wave output UPS on-line double conversion type. INPUT AC Mains voltage 230V ac 1 phase Mains voltage range 184...264V ac Mains frequency range 47...63Hz Power factor at
More informationTENTATIVE PP225D120. POW-R-PAK TM 225A / 1200V Half Bridge IGBT Assembly. Description:
Description: The Powerex is a configurable IGBT based power assembly that may be used as a converter, chopper, half or full bridge, or three phase inverter for motor control, power supply, UPS or other
More informationADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -
ADJUSTABLE SPEED DRIVES HX7 Series 18 Pulse Toshiba HX7 In some industrial applications, users need reliable and efficient adjustable speed drives that do not contribute significant harmonic distortion
More informationWaterpower '97. Upgrading Hydroelectric Generator Protection Using Digital Technology
Waterpower '97 August 5 8, 1997 Atlanta, GA Upgrading Hydroelectric Generator Protection Using Digital Technology Charles J. Beckwith Electric Company 6190-118th Avenue North Largo, FL 33773-3724 U.S.A.
More informationSCR CONTROLLER SYSTEM
SCR CONTROLLER SYSTEM 152 Nickle Road Harmony PA Phone (724) 452-5787 Fax: (724) 452-4791 www.pcti.com Control and Firing Circuit The SCR controller system has two printed circuit boards: The first board
More informationReducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems
Reducing the Effects of Short Circuit Faults on Sensitive Loads in Distribution Systems Alexander Apostolov AREVA T&D Automation I. INTRODUCTION The electric utilities industry is going through significant
More informationSequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network
Preface p. iii Introduction and General Philosophies p. 1 Introduction p. 1 Classification of Relays p. 1 Analog/Digital/Numerical p. 2 Protective Relaying Systems and Their Design p. 2 Design Criteria
More information